Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.260
Filtrar
1.
J Indian Soc Pedod Prev Dent ; 42(3): 240-248, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39250209

RESUMEN

INTRODUCTION: Caries in primary teeth rapidly advances owing to its thin structure, thereby requiring restoration. However, restorations often fail due to various causes such as secondary caries and reduced microtensile bond strength (µTBS), which calls for the use of antimicrobial agents such as silver diamine fluoride (SDF). AIM: This study aims to measure and analyse the effect of SDF application on the µTBS of three regularly used restorative materials to dentin of primary teeth as well as compare the types of bond failure interfaces under SEM. MATERIALS AND METHODS: The study comprised 60 samples equally divided into six groups among three restorative materials, namely, glass ionomer cement (GIC, Groups I and II), resin-modified glass ionomer cement (RMGIC, Groups III and IV), and composite resin (Groups V and VI) with subdivisions of A and B, where A represented samples with SDF application and B represented samples without SDF application. RESULTS AND OBSERVATIONS: It was observed that µTBS of RMGIC to sound and carious dentin irrespective of SDF application was found to be statistically significant (P < 0.05), and when GIC, RMGIC, and composite resins were compared to both sound and carious dentin irrespective of SDF application, it was statistically significant (P < 0.05). SEM analysis revealed predominantly cohesive failures among all the groups. CONCLUSION: Based on the results, it was concluded that SDF has no adverse effect on the µTBS of GIC, RMGIC, and composite resin to both carious and sound dentin of primary teeth.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Fluoruros Tópicos , Cementos de Ionómero Vítreo , Compuestos de Amonio Cuaternario , Compuestos de Plata , Resistencia a la Tracción , Diente Primario , Humanos , Fluoruros Tópicos/farmacología , Resinas Compuestas/química , Cementos de Ionómero Vítreo/farmacología , Compuestos de Amonio Cuaternario/farmacología , Compuestos de Amonio Cuaternario/química , Recubrimiento Dental Adhesivo/métodos , Microscopía Electrónica de Rastreo , Dentina/efectos de los fármacos , Ensayo de Materiales , Restauración Dental Permanente/métodos , Caries Dental , Materiales Dentales/química
2.
Int J Nanomedicine ; 19: 9255-9271, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39282577

RESUMEN

Background: Polymeric denture materials can be susceptible to colonization by oral microorganisms. Zein-coated magnesium oxide nanoparticles (zMgO NPs) demonstrate antimicrobial activity. The aim of this study was to investigate the antimicrobial effect and adherence of different oral microorganisms on hybrid polymeric denture materials incorporated with zMgO NPs. Methods: Five types of polymeric denture materials were used. A total of 480 disc-shaped specimens were divided by material type (n=96/grp), then subdivided by zMgO NPs concentration: control with no nanoparticles and other groups with zMgO NPs concentrations of 0.3%, 0.5% and 1% by weight. Characterization of the polymeric denture materials incorporating zMgO NPs was done, and the antimicrobial activity of all groups was tested against four types of microorganisms: 1) Streptococcus mutans, 2) Staphylococcus aureus, 3) Enterococcus faecalis and 4) Candida albicans. The samples underwent an adherence test and an agar diffusion test. Experiments were done in triplicates. Results: The characterization of the hybrid samples revealed variation in the molecular composition, as well as a uniform distribution of the zMgO NPs in the polymeric denture materials. All hybrid polymeric denture materials groups induced a statistically significant antimicrobial activity, while the control groups showed the least antimicrobial activity. The agar diffusion test revealed no release of the zMgO NPs from the hybrid samples, indicating the NPs did not seep out of the matrix. Conclusion: The zMgO NPs were effective in reducing the adherence of the tested microorganisms and enhancing the antimicrobial activity of the polymeric denture materials. This antimicrobial effect with the polymeric dentures could aid in resisting microbial issues such as denture stomatitis.


Asunto(s)
Antiinfecciosos , Candida albicans , Staphylococcus aureus , Streptococcus mutans , Zeína , Zeína/química , Zeína/farmacología , Candida albicans/efectos de los fármacos , Streptococcus mutans/efectos de los fármacos , Staphylococcus aureus/efectos de los fármacos , Antiinfecciosos/farmacología , Antiinfecciosos/química , Óxido de Magnesio/química , Óxido de Magnesio/farmacología , Nanopartículas/química , Enterococcus faecalis/efectos de los fármacos , Pruebas de Sensibilidad Microbiana , Humanos , Materiales Dentales/farmacología , Materiales Dentales/química , Dentaduras/microbiología , Polímeros/química , Polímeros/farmacología
3.
BMC Oral Health ; 24(1): 1089, 2024 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-39277736

RESUMEN

BACKGROUND: To predict the long-term performance of restorative materials in the oral environment, it is important to evaluate their resistance to chemical and mechanical degradation and to know the toxic potential of the type and amount of ions eluted from the filling material. In this study, home bleaching was applied to dental materials with different contents and it was aimed to determine the type and amount of ions released from these materials. METHODS: In this study, amalgam, posterior composite resin, anterior composite resin, bulk fill composite resin, indirect composite resin, hybrid ceramic and all-ceramic were used as restorative materials. 10 specimens of each material were prepared according to the manufacturer's instructions. Each material group was divided into two subgroups as the bleached group and the control group. After bleaching, all specimens were stored in 1 ml of 75% ethanol/water solution. Solutions were renewed after 1, 14 and 28 days. The type and amount of ions released from the materials were determined using Inductively Coupled Plasma-Mass Spectrometer (ICP-MS). Data were analyzed using the Friedman, Wilcoxon Signed Ranks, and Mann-Whitney U tests (α = 0.05). RESULTS: It was determined that the amount of ions release from the restorative materials decreased over time (p < 0.05). According to the results of the Mann-Whitney U test, there was no difference between the bleaching and control groups in most of the restorative materials (p > 0.05). CONCLUSION: Within the limits of this study, home bleaching system does not have a significant effect on ion release from restorative materials.


Asunto(s)
Peróxido de Carbamida , Resinas Compuestas , Amalgama Dental , Materiales Dentales , Restauración Dental Permanente , Ensayo de Materiales , Peróxidos , Blanqueadores Dentales , Urea , Peróxido de Carbamida/farmacología , Peróxidos/química , Resinas Compuestas/química , Blanqueadores Dentales/química , Amalgama Dental/química , Urea/análogos & derivados , Urea/química , Restauración Dental Permanente/métodos , Materiales Dentales/química , Iones , Cerámica/química , Humanos , Factores de Tiempo
4.
BMC Oral Health ; 24(1): 1033, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39227885

RESUMEN

BACKGROUND: The accuracy of intraoral scanning is critical for computer-aided design/computer-aided manufacturing workflows in dentistry. However, data regarding the scanning accuracy of various adjacent restorative materials and intraoral scanners are lacking. This in vitro study aimed to evaluate the effect of adjacent restorative material type and CEREC's intraoral scanners on the accuracy of intraoral digital impressions for inlay cavities. METHODS: The artificial tooth was prepared with an occlusal cavity depth of 2 mm, a proximal box width at the gingival floor of 1.5 mm, and an equi-gingival margin extended disto-occlusally at the transition line angle on both the lingual and buccal sides for an inlay restoration. The adjacent teeth were veneered with crowns made of gold and zirconia, and an artificial tooth (resin) was utilized as the control group. The inlay cavity and adjacent teeth (Gold, Zirconia, and resin) were scanned 10 times using Chairside Economical Restoration of Esthetic Ceramics (CEREC) Primescan (PS), Omnicam (OC), and Bluecam (BC). A reference scan was obtained using a laboratory scanner (3-shape E3). Scanning was performed according to the manufacturer's instructions, including powder application for the BC group. Standard tesselation language files were analyzed using a three-dimensional analysis software program. Experimental data were analyzed using a two-way analysis of variance and the Tukey's post-hoc comparison test. RESULTS: The restorative materials of the adjacent teeth significantly affected the accuracy of the intraoral digital impressions (p < .05). The zirconia group exhibited the highest trueness deviation, followed by the resin and gold groups, with each demonstrating a statistically significant difference (p < .05). The resin group demonstrated the highest maximum positive deviation and deviation in precision. Gold exhibited the lowest average deviation value for trueness compared with those of the other adjacent restorative materials. Intraoral scanner type significantly influenced the trueness and precision of the scan data (p < .05). The average deviation of trueness according to the intraoral scanner type increased in the following order: BC > PS > OC. The average deviation in precision increased in the following order: PS>OC>BC (p < .05). CONCLUSION: The restorative materials of the adjacent tooth and the type of intraoral scanner affect the accuracy of the intraoral digital impression. The trueness of the digital images of the BC group, obtained by spraying the powder, was comparable to that of the PS group. Among the adjacent restorative materials, zirconia exhibited the lowest trueness. In contrast, PS demonstrated the highest precision among the intraoral scanners, while resin displayed the lowest precision among the adjacent restorative materials.


Asunto(s)
Diseño Asistido por Computadora , Incrustaciones , Circonio , Humanos , Técnica de Impresión Dental , Técnicas In Vitro , Materiales Dentales , Coronas , Cerámica , Diseño de Prótesis Dental/métodos , Restauración Dental Permanente/métodos
5.
Br Dent J ; 237(5): 400-406, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39271876

RESUMEN

This clinical paper provides an in-depth exploration of advanced techniques for bonding orthodontic attachments under special circumstances. Challenges arise when bonding brackets to non-enamel surfaces, such as dental restorations, and in conditions such as amelogenesis imperfecta, which affect enamel integrity. Distinct approaches required for bonding to different restorative materials, including glassy ceramics, zirconia, resin composites and metals, are outlined. Moreover, we describe strategies to manage bonding in conditions including amelogenesis imperfecta, hypodontia and microdontia in a multidisciplinary context.


Asunto(s)
Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Humanos , Recubrimiento Dental Adhesivo/métodos , Amelogénesis Imperfecta/terapia , Anodoncia/terapia , Resinas Compuestas , Materiales Dentales
6.
BMC Oral Health ; 24(1): 1081, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39272090

RESUMEN

BACKGROUND: Decreased salivary flow can make the patients uncomfortable with their complete dentures and affects the retention of the dentures. Milling and 3D printing have become an alternative to conventional denture construction techniques. The goal of this study was to evaluate the effect of conventional and digital techniques of the complete denture construction on the denture surface wettability with distilled water and saliva substitute before and after thermocycling. METHODS: A total of 30 specimens were utilized in the present study. Specimens were divided according to the construction techniques into 3 groups (n = 10 each). Group I: Heat-polymerized polymethylmethacrylate (PMMA) group, group II: Milled group, and group III: 3-dimensional (3D)-printed group. All the specimens were subjected to 2000 cycles of thermal aging in a thermocycler. The wettability of all specimens to water and saliva substitute was measured via a contact angle goniometer (Olympus TGHM, Rame-hart Inc, USA) before and after thermocycling. Descriptive statistical analysis, plots, and the Shapiro-Wilk test were used to verify normality for each variable. One-way ANOVA was used to compare the 3 study groups, while paired samples t-test was used to compare the differences within each group (P < .05). RESULTS: The smallest contact angle of drop of water to the denture base specimens before and after thermocycling were recorded in the milled group (53.0 ± 4.77 and 50.27 ± 2.30, respectively), followed by the heat polymerized PMMA group (85.65 ± 4.71 and 65.06 ± 2.27, respectively), and the 3D-printed group (91.34 ± 6.74 and 90.86 ± 8.57, respectively). While the smallest contact angle of drop of saliva substitute to denture base specimens was recorded in the milled group (56.82 ± 2.29 and 34.85 ± 7.51, respectively), followed by the 3D-printed group (72.87 ± 4.83 and 58.14 ± 9.58, respectively) and the heat polymerized PMMA group (83.62 ± 4.12 and 67.82 ± 4.93, respectively). There was statistically significant difference between the groups (P < .05). A significant decline in the average contact angle of drop of saliva has been reported in all groups after thermocycling. The contact angle values differed significantly between saliva substitute and distilled water in both 3D-printed and milled groups after thermocycling (P < .001). CONCLUSIONS: The milled denture base material presented the best wettability to water and saliva substitute than the 3D-printed and the heat-polymerized PMMA materials. Saliva substitutes improve the wetting ability of denture base materials manufactured by CAD/CAM compared with water.


Asunto(s)
Bases para Dentadura , Dentadura Completa , Polimetil Metacrilato , Impresión Tridimensional , Humectabilidad , Polimetil Metacrilato/química , Humanos , Técnicas In Vitro , Diseño de Dentadura , Materiales Dentales/química , Ensayo de Materiales , Propiedades de Superficie , Diseño Asistido por Computadora , Agua
7.
Br Dent J ; 237(5): 313, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39271864
8.
J Clin Pediatr Dent ; 48(5): 131-137, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39275830

RESUMEN

Recently, interest in tooth-colored fluoride-releasing dental materials has increased. Although physical and mechanical properties such as surface hardness, elastic modulus and surface roughness of the restorative materials have been investigated, the effect of different immersion media on these properties is still controversial. The aim of this study was to evaluate the nanohardness, elastic modulus and surface roughness of the fluoride release of tooth-colored restorative materials after immersion in acidic beverages. Prepared samples of three restorative materials (a highly viscous glass ionomer (EQUIA Forte; GC, Tokyo, Japan), a compomer (Dyract XP; Dentsply, Weybridge, UK), and a bioactive restorative material (Activa BioACTIVE; Pulpdent, MA, USA)) were randomly divided and immersed in distilled water, a cola and an orange juice for one week. The HYSITRON T1 950 TriboIndenter device (Hysitron, USA) with the Berkovich diamond indenter tip was used for all measurements. The nanohardness and elastic modulus of the samples were measured by applying a force of 6000 µN to five different points on the sample surface. Surface roughness measurements were evaluated on random samples by scanning five random 40 × 40 µm areas. The properties were measured at the initial and one week after immersion. The values of nanohardness, elastic modulus and surface roughness were tested for significant differences using a two-way analysis of variance (ANOVA) with repeated measures (p < 0.05). Tukey's honest significant difference (HSD) test was used for multiple comparisons. AB (Activa BioACTIVE) had the highest initial mean values for nanohardness. After post-immersion, the highest mean value for elastic modulus was the initial AB value. The lowest mean value for roughness of 100.36 nm was obtained for the initial DX (Dyract XP) measurement. Acidic beverages had a negative effect on the nanohardness, elastic modulus and surface roughness of the restorative materials.


Asunto(s)
Bebidas Gaseosas , Módulo de Elasticidad , Fluoruros , Dureza , Ensayo de Materiales , Propiedades de Superficie , Fluoruros/química , Compómeros/química , Humanos , Materiales Dentales/química , Jugos de Frutas y Vegetales , Resinas Acrílicas/química , Restauración Dental Permanente/métodos , Agua/química , Cariostáticos/química , Cementos de Ionómero Vítreo/química , Citrus sinensis/química , Inmersión , Resinas Compuestas/química , Dióxido de Silicio
9.
Braz Oral Res ; 38: e077, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39258630

RESUMEN

Borosilicate glass was developed to enhance the mechanical behavior and smoothness of dental zirconia as an alternative to conventional glaze. This study assessed the mechanical and optical properties of 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) coated with borosilicate glass or a commercial glaze fired for an extended period of time. Disc-shaped 3Y-TZP zirconia specimens (Zpex, Tosoh) were sintered at 1550°C for 2 hours. The specimens were divided into three groups: as-sintered (control, C); commercial glaze (G); and borosilicate glass (SL). The glaze and borosilicate glass were applied over the zirconia and fired for 20 minutes at 950°C and 1200°C, respectively. Biaxial flexural strength, fractography, X-ray diffraction (XRD), roughness (Ra and Rz), fracture toughness (Vickers indentation method), color difference (∆E00), and translucency (TP00) analyses were conducted. The t-test or the one-way ANOVA and Tukey's tests were used to analyze the data (α = 0.05). Flexural strength data were subjected to the Weibull analysis. The SL group exhibited the highest flexural strength (1025.8 MPa), whereas the C (859.41 MPa) and G (816.0 MPa) groups exhibited similar values. The SL group also had the highest characteristic strength. The fracture origin in all groups was on the zirconia surface. XRD analysis revealed that the specimens from the SL group contained tetragonal, cubic, and monoclinic phases. The SL group presented the lowest surface roughness. Fracture toughness in the SL group was lower than in the C group, but similar to that observed in the G group. The translucency and color differences observed in the G and SL groups were similar. Borosilicate glass enhanced the flexural strength of 3Y-TZP, promoted the smoothest surface, and exhibited optical properties similar to those of the glaze.


Asunto(s)
Vidrio , Ensayo de Materiales , Propiedades de Superficie , Difracción de Rayos X , Itrio , Circonio , Circonio/química , Itrio/química , Vidrio/química , Análisis de Varianza , Factores de Tiempo , Resistencia Flexional , Silicatos/química , Reproducibilidad de los Resultados , Valores de Referencia , Estadísticas no Paramétricas , Color , Fenómenos Ópticos , Pruebas de Dureza , Materiales Dentales/química
10.
Med Sci Monit ; 30: e945130, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39252410

RESUMEN

BACKGROUND This 3-dimensional (3D) optical study aimed to evaluate the effects of microwave glazing on the surface roughness of zirconia-reinforced glass. Glazed surfaces of ceramic provide a smooth and esthetically superior restoration. There are many methods of glazing. However, this study aims to evaluate the effect of microwave glazing on ceramic restorations over conventional oven and hand polishing. MATERIAL AND METHODS A sample size of 90 ceramic material tiles was derived according to the standard sample size formula. The 3 dental ceramics used were IPS e.max CAD (lithium disilicate ceramic; IvoclarVivadent), Suprinity (zirconia-reinforced lithium silicate; VITA Zahnfabrik), and Celtra Duo zirconia-reinforced lithium silicate; Dentsply Sirona). Each group was further divided equally to undergo conventional oven glazing, hand polishing, and microwave glazing. The final glazed surfaces were then evaluated for surface roughness with the Ra parameter, using a Contour GT 3D Optical Microscope (Bruker) and 3D non-contact surface metrology with interferometry. RESULTS The ANOVA test for intergroup comparison showed microwave glazing was a significantly better glazing method than conventional oven and hand polishing (P<0.05). A statistically significant difference was shown between conventional and microwave glazing; however, the difference was greater between conventionally glazed and hand-polished specimens. Furthermore, a highly significant difference between microwave-glazed and hand-polished specimens was observed. CONCLUSIONS Results showed that irrespective of the ceramic, microwave-glazed ceramics were better than traditional oven-glazed ceramics, and hand-polishing resulted in a rougher surface than glazing. Irrespective of the surface treatment methods, IPS e.max CAD ceramic showed a relatively smoother surface than did Suprinity and Celtra Duo.


Asunto(s)
Cerámica , Porcelana Dental , Microondas , Propiedades de Superficie , Circonio , Circonio/química , Cerámica/química , Porcelana Dental/química , Ensayo de Materiales/métodos , Humanos , Materiales Dentales/química , Vidrio/química
11.
J Dent ; 149: 105314, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39168231

RESUMEN

OBJECTIVES: The fluorescence-aided identification technique (FIT) is based on the fluorescence properties of dental materials, specifically the intensity of their fluorescence compared to the autofluorescence of hard dental substances; this creates a perceived contrast between dental material and tooth. However, no studies to date have determined the extent to which the fluorescence intensity of tooth-colored dental materials must differ from that of natural autofluorescence to ensure reliable visual detection. The aim of this study was therefore to determine, for the first time, how pronounced the difference between fluorescence intensity and autofluorescence must be to reliably identify tooth-colored material. METHODS: Ten dentists assessed six different resin-based composite (RBC) samples of varying fluorescence intensity placed in the cavities of ten extracted teeth under standardized fluorescence-exciting illumination. The outcome variable was fluorescence perceptibility. Their assessments of the outcome variable were compared with measurements of the fluorescence intensities of the RBCs and the surrounding dental hard tissues, which were expressed as a fluorescence intensity ratio. Demographic data of the participants, including age, gender, and professional experience, were also recorded. RESULTS: No significant differences were found for visual fluorescence perceptibility in relation to the explanatory variables of gender (p = 0.14), age (p = 0.13), and professional experience (p = 0.34). In contrast, the fluorescence intensity ratio was significantly different (p < 0.0001). SIGNIFICANCE: For both clinicians and manufacturers, fluorescence intensity levels are important when selecting or developing FIT-compatible materials. Our results suggest that the fluorescence intensity levels of dental materials should be no more than 75% and no less than 200% of tooth natural autofluorescence to ensure reliable detection of tooth-colored materials.


Asunto(s)
Resinas Compuestas , Humanos , Fluorescencia , Masculino , Femenino , Resinas Compuestas/química , Adulto , Materiales Dentales/química , Persona de Mediana Edad , Diente/diagnóstico por imagen , Diente/química , Color
12.
BMC Oral Health ; 24(1): 1000, 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39183299

RESUMEN

BACKGROUND: Digitally fabricated dentures may require relining due to continual alveolar ridge resorption. However, studies evaluating the tensile bond strength (TBS) of digitally fabricated dentures bonded to denture liners are lacking. This study aimed to evaluate the TBS of autopolymerized, heat-polymerized, milled, and 3D printed denture base materials bonded to 2 acrylic-based and 2 silicone-based denture liners, both before and after thermocycling. Additionally, the impact of thermocycling on the TBS were also evaluated. METHODS: The TBS of 4 different denture base materials (Palapress (PL), Vertex Rapid Simplified (VR), Smile CAM total prosthesis (SC), and NextDent denture 3D+ (ND)) bonded to 2 acrylic-based (GC Soft-Liner (GC) and Tokuyama Rebase II (RB)) and 2 silicone-based (Ufi Gel P (UP) and Sofreliner Tough M (ST)) denture liners were tested. Specimens (n = 8) were divided into non-thermocycling and thermocycling groups. Non-thermocycling specimens were tested after 24-hours water immersion, while thermocycling specimens were underwent 5000 cycle and were immediately tested. Mode of failure was examined under a stereomicroscope. Data were analyzed using 2-way ANOVA and Tukey HSD tests (α = 0.05), and independent samples t test (α = 0.05) for TBS between non-thermocycling and thermocycling groups. RESULTS: For the non-thermocycling groups, within the same denture liner material, no significant differences were found between denture base materials, except the ND + RB group, which had significantly lower TBS. For the thermocycling groups, within the same denture liner material, the TBS in the PL group exhibited the highest and the ND group exhibited the lowest. Within the same denture base material, in both non-thermocycling and thermocycling groups, the TBS in the ST group exhibited the highest; in contrast, that in the GC group exhibited the lowest. No significant differences were observed in TBS between non-thermocycling and thermocycling groups, except for denture base materials bonded to the ST group, SC + UP, and ND + UP groups. CONCLUSIONS: Milled denture base can be relined with acrylic-based or silicone-based denture liner. However, cautions should be exercised when relining 3D printed denture base. Thermocycling did not affect TBS between acrylic-based denture liners and denture bases. In contrast, it affected the bond between silicone-based denture liner and denture base.


Asunto(s)
Bases para Dentadura , Alineadores Dentales , Ensayo de Materiales , Impresión Tridimensional , Resistencia a la Tracción , Resinas Acrílicas/química , Recubrimiento Dental Adhesivo/métodos , Humanos , Polimerizacion , Materiales Dentales/química , Técnicas In Vitro , Calor , Análisis del Estrés Dental , Polimetil Metacrilato/química , Siliconas/química , Elastómeros de Silicona/química
13.
BMC Oral Health ; 24(1): 902, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107737

RESUMEN

BACKGROUND: Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone density sites such as the maxilla as it is categorized as type III & IV bone, so searching for a new innovation and updates in implant material and features is very mandatory. So, the aim of this study was to compare between two implant materials (roxolid and traditional titanium) on the primary and secondary stability of implant retained maxillary overdenture. METHODS: Eighteen completely edentulous patients were selected. All patients received maxillary implant-retained overdentures and lower complete dentures; patients were divided equally into two groups according to the type of implant materials. Group A received a total number of 36 implants made of roxolid material and Group B received a total number of 36 implants made of traditional titanium alloys. Implant stability was assessed using ostell device, the primary implant stability was measured at the day of implant installation however, secondary implant stability was measured after six weeks of implant placement. Paired t-test was used to compare between primary and secondary stability in the same group and an independent t-test was used to compare between the two groups with a significant level < 0.05. RESULTS: Independent t-test revealed a significant difference between the two groups with p -value = 0.0141 regarding primary stability and p-value < 0.001 regarding secondary stability, as roxolid implant group was statistically higher stability than titanium group in both. Paired t- test showed a statistically significant difference in roxolid implant group with p-value = 0.0122 however, there was non-statistically significant difference in titanium group with p-value = 0.636. Mann Whitney test showed a significant difference between the two groups regarding amount of change in stability with p value = 0.191. roxolid implant group showed a higher amount of change in stability than the titanium implant group. CONCLUSION: Within the limitation of this study, it could be concluded that: Roxolid implants showed promising results regarding primary and secondary stability compared to conventional Titanium implants and can be a better alternative in implant retained maxillary overdentures. TRIAL REGISTRATION: Retrospectively NCT06334770 at 26-3-2024.


Asunto(s)
Prótesis Dental de Soporte Implantado , Prótesis de Recubrimiento , Maxilar , Titanio , Humanos , Masculino , Femenino , Maxilar/cirugía , Persona de Mediana Edad , Implantes Dentales , Aleaciones Dentales/química , Anciano , Circonio , Retención de Dentadura , Materiales Dentales/química , Aleaciones
14.
BMC Oral Health ; 24(1): 901, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107754

RESUMEN

BACKGROUND: Mechanical complications affect the stability of implant restorations and are a key concern for clinicians, especially with the frequent introduction of new implant designs featuring various structures and materials. This study evaluated the effect of different prosthetic index structure types and implant materials on the stress distribution of implant restorations using both in silico and in vitro methods. METHODS: Four finite element analysis (FEA) models of implant restorations were created, incorporating two prosthetic index structures (cross-fit (CF) and torc-fit (TF)) and two implant materials (titanium and titanium-zirconium). A static load was applied to each group. An in vitro study using digital image correlation (DIC) with a research scenario identical to that of the FEA was conducted for validation. The primary strain, sensitivity index, and equivalent von Mises stress were used to evaluate the outcomes. RESULTS: Changing the implant material from titanium to titanium-zirconium did not significantly affect the stress distribution or maximum stress value of other components, except for the implant itself. In the CF group, implants with a lower elastic modulus increased the stress on the screw. The TF group showed better stress distribution on the abutment and a lower stress value on the screw. The TF group demonstrated similar sensitivity for all components. DIC analysis revealed significant differences between TF-TiZr and CF-Ti in terms of the maximum (P < 0.001) and minimum principal strains (P < 0.05) on the implants and the minimum principal strains on the investment materials in both groups (P < 0.001). CONCLUSIONS: Changes in the implant material significantly affected the maximum stress of the implant. The TF group exhibited better structural integrity and reliability.


Asunto(s)
Implantes Dentales , Materiales Dentales , Análisis del Estrés Dental , Análisis de Elementos Finitos , Titanio , Circonio , Circonio/química , Humanos , Materiales Dentales/química , Análisis del Estrés Dental/métodos , Estrés Mecánico , Diseño de Prótesis Dental , Módulo de Elasticidad , Simulación por Computador , Imagenología Tridimensional
15.
Sci Rep ; 14(1): 17885, 2024 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-39095406

RESUMEN

Dental materials are challenged by wear processes in the oral environment and should be evaluated in laboratory tests prior to clinical use. Many laboratory wear-testing devices are high-cost investments and not available for cross-centre comparisons. The 'Rub&Roll' wear machine enables controlled application of force, chemical and mechanical loading, but the initial design was not able to test against rigid antagonist materials. The current study aimed to probe the sensitivity of a new 'Rub&Roll' set-up by evaluating the effect of force and test solution parameters (deionized water; water + abrasive medium; acid + abrasive medium) on the wear behaviour of direct and indirect dental resin-based composites (RBCs) compared with human molars against 3D-printed rod antagonists. Molars exhibited greater height loss than RBCs in all test groups, with the largest differences recorded with acidic solutions. Direct RBCs showed significantly greater wear than indirect RBCs in the groups containing abrasive media. The acidic + abrasive medium did not result in increased wear of RBC materials. The developed method using the 'Rub&Roll' wear machine in the current investigation has provided a sensitive wear test method to allow initial screening of resin-based composite materials compared with extracted human molars under the influence of different mechanical and erosive challenges.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Ensayo de Materiales , Humanos , Ensayo de Materiales/métodos , Resinas Compuestas/química , Diente Molar , Propiedades de Superficie
16.
BMC Oral Health ; 24(1): 913, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39118080

RESUMEN

OBJECTIVES: This study aimed to evaluate the feasibility of monolithic zirconia laminate veneers (MZLV) compared to lithium disilicate laminate veneers (LDLV). MATERIALS AND METHODS: Sixty resin replicas, each prepared with depths of 0.5 mm, 0.7 mm, and 1 mm, were produced using a 3D printer from acrylic teeth. Laminate veneers of these thicknesses were milled from pre-sintered monolithic zirconia (3rd generation) and lithium disilicate blocks. The intaglio surface of MZLV was treated with air abrasion using 110 µm diameter silica-modified aluminium oxide particles and ceramic primer, while LDLV was etched with etchant gel and treated with the ceramic primer before cementation with resin cement. Vertical marginal discrepancy (VMD) was assessed using a stereomicroscope, and a load-to-failure test was conducted using a universal testing machine. Failure modes were evaluated macroscopically on fractured surfaces. Data were analysed statistically using Two-way ANOVA and Bonferroni correction (α = 0.05). RESULTS: LDLV samples exhibited significantly larger VMD compared to MZLV samples across all thicknesses, especially in cervical, palatal, and mean data. Within the LDLV group, load-to-fracture values for 0.7 mm and 1.0 mm thicknesses were similar, whereas for 0.5 mm thickness, it was significantly lower. In the MZLV group, load-to-fracture values were lower for 0.7 mm and 1.0 mm thicknesses compared to LDLV, but higher for 0.5 mm thickness. CONCLUSIONS: Material choice and restoration thickness significantly influence laminate veneer restorations' success. MZLV generally exhibits superior vertical marginal fit compared to LDLV, with varying load-to-failure values across different thicknesses. Clinical management of debonding in MZLV is simpler compared to restoration fracture in LDLV. CLINICAL RELEVANCE: Considering clinical factors, MZLV may be a preferable option to LDLV for this restoration with the thickness of 0.5 mm.


Asunto(s)
Adaptación Marginal Dental , Porcelana Dental , Coronas con Frente Estético , Circonio , Porcelana Dental/química , Circonio/química , Humanos , Ensayo de Materiales , Análisis del Estrés Dental , Fracaso de la Restauración Dental , Propiedades de Superficie , Materiales Dentales/química , Diseño de Prótesis Dental
17.
Pediatr Dent ; 46(4): 271-276, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39123321

RESUMEN

Purpose: To evaluate whether reduced curing performance due to compromised light tip placement can be mitigated by bulk-fill composite and/or high-intensity curing light. Methods: Plastic discs with 2.5-mm deep cavities were filled with a conventional (Mosaic™) or bulk-fill (Tetric® PowerFill) composite and cured with a BluePhase® PowerCure curing light at normal and high-power settings, with light tip placement at distance and/or 45 degree angle. Curing time and irradiance were three, five, or 10 seconds at 1,200, 2,000, or 3,000 mW/cm2 (10 samples). After 24 hours, Vickers hardness on top and bottom surfaces was measured and analyzed using analysis of variance and pairwise comparisons (α<0.05). Results: All top surfaces had higher hardness than bottom surfaces. Cure (bottom-to-top hardness ratio) was significantly affected by material, distance/angle, and curing regimen (P<0.001), and generally decreased when tip distance and angle increased. Bottom-to-top hardness ratios of bulk-fill composite (0.42 to 0.66) were significantly higher than those of conventional composite (0.20 to 0.31). High-power curing significantly increased bulk-fill's curing performance as it was specifically formulated for this curing light. Conclusions: Increased light tip distance and angle compromised composite curing. Bulk-fill composite cured better at the bottom of the restoration than conventional composite regardless of light tip distance/angle. High-power light curing improved curing performance only in bulk-fill composite. Nevertheless, due to low bottom-to-top ratios (0.20 to 0.66) across all samples, even under ideal light tip placement, both composites should be cured in increments of less than 2.5 mm.


Asunto(s)
Resinas Compuestas , Luces de Curación Dental , Dureza , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Resinas Compuestas/química , Resinas Compuestas/efectos de la radiación , Curación por Luz de Adhesivos Dentales/métodos , Propiedades de Superficie , Humanos , Polimerizacion , Materiales Dentales/química
18.
Dent Med Probl ; 61(4): 585-592, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39194302

RESUMEN

BACKGROUND: The application of natural products in dentistry has been widely explored. Anchovy (Stolephorus in Latin) has been examined for its bioactive content (calcium, phosphorus and fluoride) as an agent for bone stimulation and tooth development, topical fluoridation and pulp capping. Ball milling has been used to prepare calcium oxide nanoparticles from snakehead fish bone. OBJECTIVES: The aim of the study was to reduce the particle size of Stolephorus sp. powder to the nanoscale using high-energy ball milling for 8, 12 and 24 h, and to analyze the optimal milling time by comparing the powder characteristics. MATERIAL AND METHODS: The Stolephorus sp. were oven-dried at 50°C for 6 h, after which the entire fish were crushed into powder. The fish powder was produced by blending the material for 5 min and passing it through a 200-mesh sieve. The remaining dried fish was blended again for 5 min until it passed through the sieve. The top-down approach to the particle size reduction was performed using high-energy milling at 3 distinct time points (8, 12 and 24 h). The characteristics of the powder were evaluated using a particle size analyzer, a Fourier-transform infrared spectrometer (FTIR) and scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS). RESULTS: The Stolephorus sp. powder contained 64.50% protein, 7,420 mg/kg sodium, 28,912 mg/kg calcium, and 1,924 mg/kg magnesium. The high-energy milling process resulted in a reduction of the particle size from the microscale to the nanoscale. The analysis of the average particle size and polydispersity index indicated that 24 h of milling showed the most optimal results. Furthermore, the functional groups exhibited no significant alteration at 3 milling times (p ≥ 0.05, FTIR analysis). CONCLUSIONS: The high-energy milling method has the potential to reduce the particle size of Stolephorus sp. powder to the nanoscale at the 8- and 24-h milling periods. The powder resulting from the 24-h milling process had a size of 789.3 ±170.7 nm, smooth size distribution, good size uniformity, a polydispersity index of 0.763, no significant change in organic and inorganic compound content, and a calcium/phosphorus ratio that was the closest to that of hydroxyapatite (HAp).


Asunto(s)
Tamaño de la Partícula , Polvos , Animales , Nanopartículas , Peces , Microscopía Electrónica de Rastreo , Espectroscopía Infrarroja por Transformada de Fourier , Materiales Dentales
19.
Clin Oral Investig ; 28(9): 473, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39110133

RESUMEN

PURPOSE: To investigate the effects of different surface treatments and thicknesses on the color, transparency, and surface roughness of ultra-transparent zirconia. METHODS: A total of 120 Katana ultra-translucent multi-layered zirconia specimens were divided into 12 groups according to the thickness (0.3, 0.5, and 0.7 mm) and surface treatment (control, airborne particle abrasion [APA], lithium disilicate coating, and glaze on). Color difference (ΔE00) and relative translucency parameter (RTP00) were calculated using a digital spectrophotometer. The surface roughness (Ra, Rq, Sa, and Sq) was measured using a non-contact profile scanner. The surface morphologies and microstructures of the samples were observed using a tungsten filament scanning electron microscope. Statistical analyses were performed by one-way and two-way analysis of variance (ANOVA) followed by post hoc multiple comparisons and Pearson's correlation (α = 0.05). RESULTS: The results showed that the surface treatment, ceramic thickness, and their interactions had significant effects on ΔE00 and RTP00 (p < 0.001). The surface treatment significantly altered the micromorphology and increased the surface roughness of the ceramic samples. APA exhibited the lowest transparency, largest color difference, and highest surface roughness. Zirconia with 0.3 mm and 0.7 mm thicknesses showed strong negative correlations between Sa and RTP00. CONCLUSIONS: The three internal surface treatments significantly altered the surface roughness, color difference, and transparency of ultra-transparent zirconia. As the thickness increased, the influence of the inner surface treatment on the color difference and transparency of zirconia decreased. CLINICAL IMPLICATIONS: For new zirconia internal surface treatment technologies, in addition to considering the enhancement effect on the bonding properties, the potential effects on the color and translucency of high-transparency zirconia should also be considered. Appropriately increasing the thickness of zirconia restorations helps minimize the effect of surface treatment on the optical properties.


Asunto(s)
Color , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Espectrofotometría , Propiedades de Superficie , Circonio , Circonio/química , Porcelana Dental/química , Materiales Dentales/química , Recubrimiento Dental Adhesivo/métodos
20.
Clin Oral Investig ; 28(9): 497, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39177681

RESUMEN

OBJECTIVES: Oral diseases, such as dental caries, periodontitis, and oral cancers, are highly prevalent worldwide. Many oral diseases are typically associated with bacterial infections or the proliferation of malignant cells, and they are usually located superficially. MATERIALS AND METHODS: Articles were retrieved from PubMed/Medline, Web of Science. All studies focusing on stimuli-responsive materials in oral diseases were included and carefully evaluated. RESULTS: Stimulus-responsive materials are innovative materials that selectively undergo structural changes and trigger drug release based on shifts at the molecular level, such as changes in pH, electric field, magnetic field, or light in the surrounding environment. These changes lead to alterations in the properties of the materials at the macro- or microscopic level. Consequently, stimuli-responsive materials are particularly suitable for treating superficial site diseases and have found extensive applications in antibacterial and anticancer therapies. These characteristics make them convenient and effective for addressing oral diseases. CONCLUSIONS: This review aimed to summarize the classification, mechanism of action, and application of stimuli-responsive materials in the treatment of oral diseases, point out the existing limitations, and speculate the prospects for clinical applications. CLINICAL RELEVANCE: Our findings may provide useful information of stimuli-responsive materials in oral diseases for dental clinicians.


Asunto(s)
Enfermedades de la Boca , Humanos , Enfermedades de la Boca/terapia , Enfermedades de la Boca/tratamiento farmacológico , Concentración de Iones de Hidrógeno , Materiales Dentales/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA