RESUMEN
PURPOSE: To evaluate microscopically the signs of inflammatory reaction due to the fixation of an orbitary implant (magnet, covered by gold). METHODS: An experimental study was performed in 54 adult female rabbits, divided into 3 groups of eighteen with 3 subgroups of 6; an evaluation at 1, 3 and 6 postoperative weeks was performed. An implant (magnet, covered by gold) was fixed in the inferior orbital rim using biologic glue, screw or unabsorbable suture (Mersilene 5.0). The opposite orbits (without implants) represented the control group. RESULTS: Microscopic signs of inflammatory reaction due to orbitary fixation of the implant were observed with the use of the three methods (biologic glue, screw or unabsorbable suture) (Mersilene 5.0), until six weeks of the postoperatory period. CONCLUSIONS: Histopathological signs of inflammatory reaction to the implant and to its orbital fixation were observed up to the sixth week, with cyanoacrylate, screw, or unabsorbable suture (Mersilene 5.0), with prevalence of the chronic inflammatory process and cicatricial fibrosis, without statistically significant difference in most of the cases.
Asunto(s)
Reacción a Cuerpo Extraño/patología , Oro , Magnetismo/efectos adversos , Órbita/cirugía , Implantes Orbitales/efectos adversos , Enfermedad Aguda , Animales , Enfermedad Crónica , Femenino , Fibrosis/patología , Órbita/patología , Conejos , Factores de TiempoRESUMEN
OBJETIVOS: Avaliação microscópica dos sinais da reação inflamatória causada pela fixação de implante orbitário (ímã, recoberto por ouro). MÉTODOS: Estudo experimental em 54 coelhas adultas, divididas em três grupos de 18, com 3 subgrupos de 6, avaliação com uma, três e seis semanas de pós-operatório. Fixação, no rebordo inferior da órbita, de implante (ímã e ouro) por meio de cola, parafuso ou fio inabsorvível (Mersilene 5.0®). As órbitas contralaterais (sem implante) compuseram o grupo-controle. RESULTADOS: Sinais histológicos de reação inflamatória à fixação orbitária do implante foram observados, com cianoacrilato, parafuso, ou sutura inabsorvível (Mersilene 5.0®), até a sexta semana pós-operatória, com predomínio do processo inflamatório crônico e fibrótico cicatricial, sem demonstrar diferenças estatisticamente significativas na maior parte dos casos. CONCLUSÃO: O exame histopatológico demonstrou, na maior parte das órbitas com e sem implante, presença de reação inflamatória aguda e crônica até a sexta semana pós-operatória, com predomínio de processo inflamatório crônico e fibrótico cicatricial, sem demonstrar, na maior parte dos casos, diferenças estatisticamente significante entre os grupos experimental e controle.
Asunto(s)
Animales , Femenino , Conejos , Reacción a Cuerpo Extraño/patología , Oro , Magnetismo/efectos adversos , Órbita/cirugía , Implantes Orbitales/efectos adversos , Enfermedad Aguda , Enfermedad Crónica , Fibrosis/patología , Órbita/patología , Factores de TiempoRESUMEN
A Estimulação Magnética Transcraniana (no original, TMS, Transcranial Magnetic Stimulation) é uma nova técnica que tem sido utilizada para o tratamento de transtornos neuropsiquiátricos, principalmente depressão. É um tratamento que utiliza um aparelho estimulador que cria um campo magnético variável no tempo, aplicado sobre o crânio através de uma bobina de estimulação. O principal risco deste tratamento são as convulsões acidentais. A TMS é utilizada na maior parte dos estudos com estímulos subliminares. Convulsões podem ocorrer acidentalmente, especialmente quando os estímulos ultrapassam os parâmetros de segurança. Neste artigo, é feita uma detalhada revisão dos oito casos em que houve convulsões acidentais com o uso da TMS. Também são descritos os possíveis mecanismos de indução das convulsões e as características dos pacientes com maior risco de convulsões acidentais.
Asunto(s)
Humanos , Masculino , Femenino , Depresión/terapia , Magnetismo/efectos adversos , Estimulación Física/métodos , Convulsiones/etiología , Estimulación Física/efectos adversos , Factores de RiesgoRESUMEN
An excess pattern of winter and spring birth, of those later diagnosed as schizophrenic, has been clearly identified in most Northern Hemisphere samples with none or lesser variation in Equatorial or Southern Hemisphere samples. Pregnancy and birth complications, seasonal variations in light, weather, temperature, nutrition, toxins, body chemistry and gene expression have all been hypothesized as possible causes. In this study, the hypothesis was tested that seasonal variation in the geomagnetic field of the earth primarily as a result of geomagnetic storms (GMS) at crucial periods in intrauterine brain development, during months 2 to 7 of gestation could affect the later rate of development of schizophrenia. The biological plausibility of this hypothesis is also briefly reviewed. A sample of eight representative published studies of schizophrenic monthly birth variation were compared with averaged geomagnetic disturbance using two global indices (AA*) and (aa). Three samples showed a significant negative correlation to both geomagnetic indices, a further three a significant negative correlation to one of the geomagnetic indices, one showed no significant correlation to either index and one showed a significant positive correlation to one index. It is suggested that these findings are all consistent with the hypothesis and that geomagnetic disturbance or factors associated with this disturbance should be further investigated in birth seasonality studies.
Asunto(s)
Magnetismo/efectos adversos , Esquizofrenia/epidemiología , Esquizofrenia/etiología , Estaciones del Año , Sistema Solar , Adulto , Anciano , Anciano de 80 o más Años , Causalidad , Comparación Transcultural , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Estadística como Asunto , Topografía MédicaRESUMEN
El propósito de este estudio fue evaluar el comportamiento de los clips metálicos para oclusión de aneurismas intracerebrales en un equipo de 1.5 tesla de resonancia magnética, basados en la hipótesis de que éstos pueden presentar movimiento. Se analizaron aquellos factores que incluyen en el comportamiento del clip y se establecieron criterios para el estudio y la protección de pacientes en quienes se ha colocado un clip metálico de cuarta o quinta generación para la oclusión de un aneurisma intracerebral
Asunto(s)
Aneurisma Intracraneal/cirugía , Magnetismo , Magnetismo/efectos adversos , Espectroscopía de Resonancia Magnética/efectos adversos , Espectroscopía de Resonancia Magnética , Instrumentos Quirúrgicos , TitanioRESUMEN
Permanent pacemaker evaluation with a magnet is an essential and widely practiced procedure used by cardiologists and electrophysiology nurses for routine pacemaker follow-up. It is generally safely performed. We present a case of a prolonged period of pacemaker inhibition in a pacemaker-dependent patient after routine magnet placement over her permanent pulse generator.