Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.014
Filtrar
2.
J Am Heart Assoc ; 13(18): e035587, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39268670

RESUMEN

BACKGROUND: Paravalvular regurgitation (PVR) is a common complication after transcatheter aortic valve replacement, posing an increased risk of heart failure and mortality. Accurate intraprocedural quantification of PVR is challenging. Both hemodynamic indices and videodensitometry can be used for intraprocedural assessment of PVR. We compared the predictive value of the isolated versus combined use of the hemodynamic index diastolic delta (DD) and videodensitometry for the incidence of relevant PVR 1 month after transcatheter aortic valve replacement. METHODS AND RESULTS: In this prospective cohort study, patients underwent periprocedural PVR assessment by DD and videodensitometry (using left ventricular outflow tract-aortic regurgitation [LVOT-AR]). Cardiac magnetic resonance served as reference modality for PVR assessment. Relevant PVR was defined as cardiac magnetic resonance-regurgitant fraction >20%. Fifty-one patients were enrolled in this study. Mean age was 80.6±5.2 years and 45.1% of patients were men. Mean LVOT-AR and cardiac magnetic resonance-regurgitant fraction were 8.2%±7.8% and 11.7%±9.6%, respectively. The correlation between DD and LVOT-AR was weak (r=-0.36). DD and LVOT-AR showed a comparable accuracy to predict relevant PVR (area under the curve 0.82, 95% CI: 0.69-0.95 versus area area under the time-density curve 0.80, 95% CI: 0.62-0.99). The combination of DD and LVOT-AR improved the prediction of relevant PVR (area under the time-density curve, 0.90, 95% CI: 0.81-0.99), and resulted in an increased concordance (86.3%) and positive predictive value (75%) compared with DD alone (76.5% and 40%, respectively), or LVOT-AR alone (82.3% and 50%, respectively). CONCLUSIONS: DD and videodensitometry are both accurate and feasible modalities for the assessment of PVR after transcatheter aortic valve replacement. The synergistic use of both techniques increases the predictive value for relevant PVR after transcatheter aortic valve replacement. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04281771.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Valor Predictivo de las Pruebas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Prospectivos , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Hemodinámica/fisiología , Diástole , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/diagnóstico
4.
JACC Cardiovasc Interv ; 17(17): 2011-2022, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39260959

RESUMEN

BACKGROUND: Asymmetrical expansion of transcatheter heart valves (THVs), manifesting as stent frame deformation, is an occasional fluoroscopic finding in transcatheter aortic valve replacement (TAVR). OBJECTIVES: The aim of this study was to investigate the impact of asymmetrical expansion of balloon-expandable THVs on hemodynamic valve performance and clinical outcomes. METHODS: In a prospective registry, TAVR asymmetry index was measured using freeze-frame fluoroscopic images and was defined as the ratio of THV heights: [(longer height/shorter height) - 1] × 100. THV hemodynamic performance was measured using echocardiography before hospital discharge. Impaired hemodynamic valve performance was defined as a mean residual THV gradient ≥20 mm Hg and/or moderate or greater paravalvular regurgitation. RESULTS: Among 1,216 patients undergoing transfemoral TAVR for native severe aortic valve stenosis with contemporary balloon-expandable THVs between February 2014 and June 2022, asymmetry index was an excellent predictor of impaired hemodynamic valve performance (area under the receiver-operating characteristic curve: 0.88; 95% CI: 0.84-0.92; P < 0.001). The optimal asymmetry index threshold for predicting impaired THV performance was >5.5% (sensitivity 77%, specificity 86%) and occurred in 17% of patients. Higher asymmetry index, as a continuous variable, was associated with impaired hemodynamic valve performance independent of total aortic valve calcium, bicuspid anatomy, balloon-expandable valve prosthesis type or size, and Society of Thoracic Surgeons Predicted Risk of Mortality score (OR: 1.37; 95% CI: 1.29-1.46; P < 0.001). High TAVR asymmetry index was not associated with all-cause mortality during a median of 376 days of follow-up (HR: 1.00; 95% CI: 0.71-1.41; P = 0.989). CONCLUSIONS: Asymmetrical expansion of balloon-expandable THVs was associated with impaired hemodynamic valve performance but not with clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Anciano , Factores de Riesgo , Factores de Tiempo , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Recuperación de la Función , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología
7.
Kyobu Geka ; 77(8): 586-589, 2024 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-39205411

RESUMEN

Case 1 was a 59-year-old man who underwent aortic valve replacement (AVR) at the age of 38, for aortic regurgitation. Case 2 was a 51-year-old man who underwent AVR at the age of 34, for aortic regurgitation. Both cases required surgery for ascending aortic aneurysms. These patients showed aneurysm at the site of the prior aortotomy. In both of the patients used felt-strip was used for closing aortotomy. Intraoperative findings showed enlargement of the aorta around the felt-strip, which was a finding of true aneurysm. Both cases underwent ascending aortic replacement. The mechanism of aortic aneurysm development was thought to include persistent mechanical stimulation by the felt-strip and ischemia of the vasa-vasorum due to compression of the felt-strip. The use of felt-strips for the aortotomy suture should be avoided, especially in young patients.


Asunto(s)
Válvula Aórtica , Humanos , Masculino , Persona de Mediana Edad , Aorta/cirugía , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/etiología , Aneurisma de la Aorta/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias
8.
Wiad Lek ; 77(5): 1093-1100, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39008603

RESUMEN

Takayasu arteriitis (TA) is a rare systemic vasculitis, affecting large vessels, cardiac valves and myocardium. Cardiac involvement is a major cause of morbidity and mortality in such patients. This publication presents a clinical case of a patient with severe aortic regurgitation combined with restrictive cardiomyopathy. It is emphasized that surgical treatment is associated with potential difficulties in patients with TA due to its inflammatory nature, disease activity and multiorgan involvement.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Arteritis de Takayasu , Humanos , Arteritis de Takayasu/complicaciones , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Femenino , Adulto
9.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38986659

RESUMEN

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Femenino , Masculino , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Readmisión del Paciente , Recuperación de la Función , Europa (Continente) , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Hemodinámica
11.
J Cardiothorac Surg ; 19(1): 329, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38867224

RESUMEN

Iatrogenic aortic regurgitation secondary to leaflet injury is a rare complication of mitral valve surgery. For the first time, we report a patient who had progressive aortic regurgitation due to non-coronary leaflet perforation after robotic mitral valve repair and required aortic valve repair 18 months after this initial surgery. As in our case, aortic regurgitation after mitral valve surgery may remain undiagnosed on intraoperative transesophageal echocardiography or undetected until the patient's discharge due to gradual enlargement of very small perforations over the postoperative course.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Ecocardiografía Transesofágica , Enfermedad Iatrogénica , Insuficiencia de la Válvula Mitral , Válvula Mitral , Procedimientos Quirúrgicos Robotizados , Humanos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Procedimientos Quirúrgicos Robotizados/efectos adversos
12.
Comput Methods Programs Biomed ; 254: 108270, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38878358

RESUMEN

BACKGROUND AND OBJECTIVE: The implantation of ventricular assist devices (VADs) has become an important treatment option for patients with heart failure. Aortic valve insufficiency is a common complication caused by VADs implantation. Currently, there is very little quantitative research on the effects of transcatheter micro VADs or the intervention pumps on the aortic valves. METHODS: In this study, the multi-component arbitrary Lagrange-Eulerian method is used to perform fluid-structure interaction simulations of the aortic valve model with and without intervention pumps. The effects of intervention pumps implantation on the opening area of the aortic valves, the stress distribution, and the flow characteristics are quantitatively analyzed. Statistical results are consistent with clinical guidelines and experiments. RESULTS: The implantation of intervention pumps leads to the valve insufficiency and causes weak valve regurgitation. In the short-term treatment, the valve regurgitation is within a controllable range. The distribution and variation of stress on the leaflets are also affected by intervention pumps. The whirling flow in the flow direction affects the closing speed of the aortic valves and optimizes the stress distribution of the valves. In the models with whirling flow, the effects of intervention pumps implantation on valve motion and stress distribution differ from those without whirling flow. However, the valve insufficiency and valve regurgitation caused by intervention pumps still exist in the models with whirling flow. Conventional artificial bioprosthetic valves have limited effectiveness in treating the valve diseases caused by intervention pumps implantation. CONCLUSIONS: This study quantitatively investigates the impact of intervention pumps on the aortic valves, and investigates the effect of blood rotation on the valve behavior, which is a gap in previous research. We suggest that in the short-term treatment, the implantation of intervention pumps has limited impact on aortic valves, caution should be exercised against valve regurgitation issues caused by intervention pumps.


Asunto(s)
Válvula Aórtica , Simulación por Computador , Corazón Auxiliar , Modelos Cardiovasculares , Humanos , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estrés Mecánico , Hemodinámica
13.
Catheter Cardiovasc Interv ; 103(7): 1093-1100, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38690931

RESUMEN

BACKGROUND: As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates. AIMS: The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR. METHODS: PAR patients who underwent TAVR with self-expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre-operative evaluation parameters and procedural and postoperative data of the two subgroups. RESULTS: The total patients' mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was -1.1 + 1.0 and 4.2 + 3.7 mm in groups A and B (p < 0.001), respectively. CONCLUSIONS: TAVR with a self-expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Factores de Tiempo , Factores de Riesgo , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Hemodinámica
14.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-38749449

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Factores de Riesgo , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Anciano de 80 o más Años , Incidencia , Factores de Tiempo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Europa (Continente) , Medición de Riesgo , Diseño de Prótesis , Oportunidad Relativa , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/diagnóstico , Estudios Retrospectivos
15.
Catheter Cardiovasc Interv ; 104(1): 115-124, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38764320

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Masculino , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Anciano de 80 o más Años , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo
16.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577923

RESUMEN

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Asunto(s)
Disección Aórtica , Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis Vascular , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Persona de Mediana Edad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Diseño de Prótesis , Prótesis Vascular , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Aortografía
17.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577931

RESUMEN

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Complicaciones Posoperatorias , Estudios Prospectivos , Recuperación de la Función , Factores de Riesgo , España , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38686682

RESUMEN

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Ecocardiografía Transesofágica , Cardiopatías Congénitas , Hallazgos Incidentales , Humanos , Femenino , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Persona de Mediana Edad , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/diagnóstico por imagen , Valor Predictivo de las Pruebas , Implantación de Prótesis de Válvulas Cardíacas , Ecocardiografía Doppler en Color
19.
Cardiovasc Pathol ; 71: 107648, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38649123

RESUMEN

This case report presents a 20-year-old male patient initially diagnosed with infective endocarditis, later correctly identified as Behçet's syndrome. The patient's complex clinical presentation, including chest pain, aortic dilation, severe aortic regurgitation, and aortic root abscess, posed significant diagnostic and therapeutic challenges. Despite initial misdiagnosis and treatment difficulties, the patient's condition significantly improved with appropriate immunosuppressive therapy, underscoring the potential for successful management of this complex condition. This case serves as a valuable reminder of the diagnostic challenges posed by Behçet's syndrome and the importance of considering this condition in patients presenting with symptoms suggestive of infective endocarditis.


Asunto(s)
Síndrome de Behçet , Errores Diagnósticos , Inmunosupresores , Humanos , Síndrome de Behçet/diagnóstico , Síndrome de Behçet/tratamiento farmacológico , Masculino , Adulto Joven , Inmunosupresores/uso terapéutico , Endocarditis/diagnóstico , Endocarditis/terapia , Endocarditis/tratamiento farmacológico , Resultado del Tratamiento , Diagnóstico Diferencial , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Valor Predictivo de las Pruebas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA