Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.585
Filtrar
1.
Acta Orthop ; 95: 492-497, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39239991

RESUMEN

BACKGROUND AND PURPOSE:  Periprosthetic femoral fracture (PFF) is a significant complication of total hip arthroplasty (THA). Although biomechanical studies have indicated that the technique by which the femoral canal is prepared plays a role, few clinical studies have reported on how this might affect the fracture risk. This study compares the fracture risk between compaction and broaching with toothed instruments in cementless THA. METHODS: Prospectively collected data from the quality register of a high-volume hospital was used. All primary arthroplasties using the Corail stem (DePuy Synthes) were included. All femoral fractures occurring within the first 90 days after the operation were included in the analysis. We determined the relative risk of sustaining PFF with compaction compared with broaching and adjusted for confounders (sex, age group, BMI, and use of a collared stem) using multivariable Poisson regression. RESULTS:  6,788 primary THAs performed between November 2009 and May 2023 were available for analysis. 66% were women and the mean age was 65.0 years. 129 (1.9%) fractures occurred during the first 90 days after the operation, 92 (2.3%) in the compaction group and 37 (1.3%) in the broaching group. The unadjusted relative risk of fracture in the compaction group compared with the broaching group was 1.82 (95% confidence interval [CI] 1.25-2.66), whereas the adjusted relative risk was 1.70 (CI 1.10-2.70). CONCLUSION: Compaction was associated with more periprosthetic fractures than broaching (2.3% versus 1.3%) within 90 days after surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fracturas Periprotésicas , Complicaciones Posoperatorias , Humanos , Femenino , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Masculino , Anciano , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Prótesis de Cadera/efectos adversos , Factores de Riesgo , Estudios Prospectivos , Complicaciones Intraoperatorias/etiología
3.
Radiography (Lond) ; 30(4): 1225-1231, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38909418

RESUMEN

INTRODUCTION: Elastic stable intramedullary nailing (ESIN) is a well-defined and appropriate treatment of choice for long bone fractures. Despite its benefits, the risk of cancer from imaging devices is of particular concern for younger adults. So, this survey was conducted to estimate the doses administered to patients undergoing ESIN of long bone fractures utilizing a 2-dimensional (2D) C-arm fluoroscopy machine during surgery, as well as the carcinogenic risk associated with the use of the machine. METHODS: This study was conducted on 147 patients who required ESIN for long-bone fractures. Patients' demographic data, surgical data and imaging information were collected. For each patient, the organ doses and the effective doses were computed with the Monte Carlo PCXMC 2.0 simulation software. The cancer risk models proposed in the Biological Effects of Ionizing Radiation VII (BEIR VII) Phase 2 report were used to evaluate the risk of exposure-induced cancer death (REID) values. RESULTS: For all patients, the highest organ dose was delivered to the gonads. The mean effective dose was 0.026 ± 0.015 mSv and 1.3E-04 ± 1E-04 mSv for ESIN of femur and tibia fractures, respectively. Males had a mean REID of 1 per million, while females had a mean REID of 0.19 per million. The younger males had considerably higher REID values. The effective dose was significantly correlated with age, gender, and irradiation time. CONCLUSION: Low levels of effective doses and cancer risks associated with the utilization of the fluoroscopy machine in current practice were found in ESIN treatment of long-bone fractures. IMPLICATIONS FOR PRACTICE: This outcome will help to raise surgeons' awareness of radiation risks and encourage them to initiate measures to keep radiation dose and exposure time as low as reasonably achievable.


Asunto(s)
Fijación Intramedular de Fracturas , Dosis de Radiación , Exposición a la Radiación , Humanos , Fluoroscopía , Masculino , Femenino , Fijación Intramedular de Fracturas/métodos , Adulto , Persona de Mediana Edad , Medición de Riesgo , Anciano , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/etiología , Clavos Ortopédicos , Neoplasias Inducidas por Radiación/etiología , Método de Montecarlo , Adulto Joven
4.
BMC Musculoskelet Disord ; 25(1): 502, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937801

RESUMEN

BACKGROUND: Jaffe-Campanacci syndrome is a rare syndrome, characterized by multiple non-ossifying fibromas (NOF) and cafe-au-lait patches. The name was coined in 1982 by Mirra after Jaffe who first described the case in 1958. Although it's suggested there is a relation with Neurofibromatosis type 1, there is still no consensus on whether Jaffe-Campanacci syndrome is a subtype or variant of neurofibromatosis-1(NF-1). CASE PRESENTATION: In this article, we present a case series of 2 patients. The first case is a 13-year-old male with Jaffe-Campanacci syndrome who presented with a distal femur fracture. His father had positive features of both Jaffe-Campanacci syndrome and NF-1, while his sister only had features of NF-1, so we presented both. CONCLUSION: Jaffe-Campanacci has a clear relationship with type 1 neurofibromatosis, which still has to be genetically established. Due to the presence of several large non-ossifying fibromas of the long bones, it is linked to a significant risk of pathological fractures. We concur with previous authors, that an osseous screening program should be performed for all patients with newly diagnosed type 1 neurofibromatosis, to identify non-ossifying fibromas and assess the potential for pathological fracture. Moreover, siblings of patients with NF-1 should be screened for multiple NOFs that may carry a high risk of pathological fractures.


Asunto(s)
Manchas Café con Leche , Neurofibromatosis 1 , Humanos , Masculino , Adolescente , Neurofibromatosis 1/diagnóstico , Neurofibromatosis 1/complicaciones , Manchas Café con Leche/diagnóstico , Manchas Café con Leche/genética , Femenino , Fibroma/diagnóstico , Fibroma/patología , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/etiología
5.
BMC Musculoskelet Disord ; 25(1): 485, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38902664

RESUMEN

BACKGROUND: Arterial injury caused by heterotopic ossification (HO) following fractures is rarely reported, yet it can have catastrophic consequences. This case report presents a unique instance of femoral artery injury and hematoma organization, occurring a decade after intramedullary nail fixation for a femoral shaft fracture complicated by HO. CASE PRESENTATION: A 56-year-old male presented with right femoral artery injury and organized hematoma, a decade after suffering bilateral femoral shaft fractures with mild head injury in a traffic accident. He had received intramedullary nailing for the right femoral shaft fracture and plate fixation for the left side in a local hospital. Physical examination revealed two firm, palpable masses with clear boundaries, limited mobility, and no tenderness. Peripheral arterial pulses were intact. Radiography demonstrated satisfactory fracture healing, while a continuous high-density shadow was evident along the inner and posterior aspect of the right thigh. Computed tomography angiography identified a large mixed-density mass (16.8 × 14.8 × 20.7 cm) on the right thigh's medial side, featuring central calcification and multiple internal calcifications. The right deep femoral artery coursed within this mass, with a smaller lesion noted on the posterior thigh. Surgical consultation with a vascular surgeon led to planned intervention. The smaller mass was completely excised, but the larger one partially, as it encased the femoral artery. The inability to remove all HO was due to excessive bleeding. Postoperatively, the patient experienced no complications, and one-year follow-up revealed a favorable recovery with restoration of full right lower limb mobility. CONCLUSION: This case underscores the potential gravity of vascular injury associated with heterotopic ossification. Surgeons should remain vigilant regarding the risk of vascular injury during HO excision.


Asunto(s)
Arteria Femoral , Fracturas del Fémur , Osificación Heterotópica , Humanos , Osificación Heterotópica/cirugía , Osificación Heterotópica/etiología , Osificación Heterotópica/diagnóstico por imagen , Osificación Heterotópica/complicaciones , Masculino , Arteria Femoral/cirugía , Arteria Femoral/lesiones , Arteria Femoral/diagnóstico por imagen , Persona de Mediana Edad , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/complicaciones , Fijación Intramedular de Fracturas , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/cirugía , Lesiones del Sistema Vascular/diagnóstico por imagen , Hematoma/etiología , Hematoma/cirugía , Hematoma/diagnóstico por imagen , Angiografía por Tomografía Computarizada
6.
J Bone Joint Surg Am ; 106(12): 1054-1061, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38900013

RESUMEN

BACKGROUND: Periprosthetic fractures can be devastating complications after total joint arthroplasty (TJA). The management of periprosthetic fractures is complex, spanning expertise in arthroplasty and trauma. The purpose of this study was to examine and project trends in the operative treatment of periprosthetic fractures in the United States. METHODS: A large, public and private payer database was queried to capture all International Classification of Diseases, Tenth Revision (ICD-10) diagnosis codes for periprosthetic femoral and tibial fractures. Statistical models were created to assess trends in treatment for periprosthetic fractures and to predict future surgical rates. An alpha value of 0.05 was used to assess significance. A Bonferroni correction was applied where applicable to account for multiple comparisons. RESULTS: In this study, from 2016 to 2021, 121,298 patients underwent surgical treatment for periprosthetic fractures. There was a significant increase in the total number of periprosthetic fractures. The incidence of periprosthetic hip fractures rose by 38% and that for periprosthetic knee fractures rose by 73%. The number of periprosthetic fractures is predicted to rise 212% from 2016 to 2032. There was a relative increase in open reduction and internal fixation (ORIF) compared with revision arthroplasty for both periprosthetic hip fractures and periprosthetic knee fractures. CONCLUSIONS: Periprosthetic fractures are anticipated to impose a substantial health-care burden in the coming decades. Periprosthetic knee fractures are predominantly treated with ORIF rather than revision total knee arthroplasty (TKA), whereas periprosthetic hip fractures are predominantly treated with revision total hip arthroplasty (THA) rather than ORIF. Both periprosthetic knee fractures and periprosthetic hip fractures demonstrated increasing trends in this study. The proportion of periprosthetic hip fractures treated with ORIF relative to revision THA has been increasing. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas Periprotésicas , Reoperación , Humanos , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/cirugía , Fracturas Periprotésicas/etiología , Estados Unidos/epidemiología , Reoperación/estadística & datos numéricos , Femenino , Fijación Interna de Fracturas/tendencias , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/estadística & datos numéricos , Masculino , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Artroplastia de Reemplazo de Cadera/tendencias , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Anciano , Incidencia , Persona de Mediana Edad , Fracturas del Fémur/cirugía , Fracturas del Fémur/epidemiología , Fracturas del Fémur/etiología , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/epidemiología
7.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38728526

RESUMEN

CASE: A 58-year-old woman with medical history of a left total hip arthroplasty performed by the direct anterior (DA) approach 2 years prior presented with left hip pain. She was found to have sustained a transverse Vancouver C periprosthetic femur fracture and an unstable periprosthetic pelvic fracture. CONCLUSIONS: This patient's case represents a previously not reported injury about a total hip arthroplasty-with disruption distal to the femoral implant and proximal to the acetabular implant, with the implant-to-bone interface unaffected. This case may guide future treatment of similar injuries.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas Periprotésicas , Humanos , Femenino , Artroplastia de Reemplazo de Cadera/efectos adversos , Persona de Mediana Edad , Fracturas Periprotésicas/cirugía , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/etiología
9.
Osteoporos Int ; 35(8): 1469-1475, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38801524

RESUMEN

Osteoporosis increases the risk of periprosthetic distal femoral fractures after TKA, especially in patients with a history of osteoporotic fractures. Therefore, careful assessment and proper treatment of osteoporosis need and the importance of taking osteoporotic medication needs to be recognized by the patients following primary TKA. PURPOSE: Osteoporosis is a risk factor for fractures, including those of the hip, vertebrae, and distal radius; however, the association between osteoporosis and periprosthetic fractures after total knee arthroplasty (TKA) has not been much investigated. Therefore, we aimed to investigate the association of the presence of systemic osteoporosis with periprosthetic fractures after TKA. METHODS: This study included 34 patients with periprosthetic fractures following primary TKA and 106 controls matched for age and sex. Bone mineral density was evaluated at the femoral neck, total hip, and lumbar spine using dual X-ray absorptiometry. Medical records were reviewed for age; sex; body mass index; smoking; rheumatoid arthritis, endocrine diseases, and cardiovascular diseases; history of glucocorticoid use; medication for osteoporosis; and history of previous osteoporotic fracture. In addition, anterior femoral notching after TKA was evaluated. Univariable and multivariable logistic regression analysis were used to determine factors associated with periprosthetic fracture. RESULTS: The prevalence of osteoporosis in the fracture group was higher than that in the control group (61.8% vs. 40.6%, p=0.045). The rate of medication for osteoporosis was significantly low in the fracture group (47.6 % vs 76.7%, p=0.026). History of previous osteoporotic fracture (odds ratio [OR], 9.1; p=0.015) and osteoporosis (OR, 3.6; p=0.013) were significant risk factors for periprosthetic fractures after TKA. Medication for osteoporosis could decrease the risk of periprosthetic fracture (OR 0.3; p=0.020). CONCLUSION: Osteoporosis is a major risk factor for periprosthetic distal femoral fractures after TKA. Therefore, careful assessment and proper treatment of osteoporosis need and the importance of taking osteoporotic medication needs to be recognized to the patients following primary TKA, especially in patients with a history of osteoporotic fracture. LEVEL OF EVIDENCE: Prognostic study, level III.


Asunto(s)
Absorciometría de Fotón , Artroplastia de Reemplazo de Rodilla , Densidad Ósea , Fracturas del Fémur , Osteoporosis , Fracturas Osteoporóticas , Fracturas Periprotésicas , Humanos , Femenino , Fracturas Periprotésicas/etiología , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fracturas Osteoporóticas/etiología , Fracturas Osteoporóticas/cirugía , Masculino , Anciano , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Osteoporosis/complicaciones , Osteoporosis/etiología , Densidad Ósea/fisiología , Persona de Mediana Edad , Absorciometría de Fotón/métodos , Estudios de Casos y Controles , Factores de Riesgo , Anciano de 80 o más Años , Estudios Retrospectivos , Fracturas Femorales Distales
10.
Orthop Clin North Am ; 55(3): 311-321, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38782503

RESUMEN

This report provides an updated analysis for patients with osteoporosis following total hip arthroplasty (THA). The comorbidities of alcohol abuse, chronic kidney disease, cerebrovascular disease, obesity, and rheumatoid arthritis continue to be significant risk factors for periprosthetic femur fracture (PPFFx) and aseptic loosening in the population with osteoporosis. Patients with dual-energy x-ray absorptiometric (DEXA) scans were at risk for PPFFx regardless of femoral fixation method, and patients with DEXA scans with cementless fixation were at risk of aseptic loosening after THA. The patient population with severe osteoporosis may have higher risks for aseptic loosening and PPFFx than previously recognized.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Osteoporosis , Fracturas Periprotésicas , Falla de Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/epidemiología , Osteoporosis/etiología , Osteoporosis/complicaciones , Factores de Riesgo , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Femenino , Masculino , Anciano , Prótesis de Cadera/efectos adversos , Absorciometría de Fotón , Persona de Mediana Edad
11.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579021

RESUMEN

CASE: A 51-year-old man and 64-year-old woman with bilateral cruciate-retaining total knee arthroplasties (CR-TKAs) who sustained unilateral periprosthetic distal femur fractures above their CR-TKA and experienced knee instability secondary to an iatrogenic posterior-cruciate-ligament (posterior cruciate ligament [PCL]) injury from retrograde intramedullary nailing. Both patients recovered knee stability after undergoing revision surgery. CONCLUSION: Many CR-TKA designs have sufficient medial-lateral intercondylar distance to place a retrograde nail, femoral components with a relatively posterior transition from the trochlear groove to the intercondylar box will necessitate a nail starting point closer to the PCL origin. This may contribute to iatrogenic postoperative knee instability for patients with CR-TKA designs.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Fijación Intramedular de Fracturas , Ligamento Cruzado Posterior , Femenino , Humanos , Masculino , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas/efectos adversos , Enfermedad Iatrogénica , Ligamento Cruzado Posterior/cirugía , Persona de Mediana Edad
12.
Arch Orthop Trauma Surg ; 144(5): 2421-2428, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38609679

RESUMEN

BACKGROUND: Femoral stem fracture following total hip arthroplasty (THA) is an infrequent but nevertheless devastating complication, with an increasing worldwide prevalence as demand for primary THA continues to increase. The aim of this study was to perform a systematic review and meta-analysis of risk factors for femoral stem fracture to help identify at risk patients. METHODS: A systematic search was conducted on EMBASE, MEDLINE and AMED to identify relevant studies. Data regarding study design, source, population, intervention, and outcomes was collated. Data extraction was performed on a custom form generated using Cochrane recommended methodology and analysis of risk factors performed including odds ratios (ORs) with 95% confidence intervals (CIs). RESULTS: A total of 15 studies reporting a total of 402 stem fractures in 49 723 THAs were identified. The median time from index procedure to stem fracture was 68 months (IQR 42.5-118) whilst mean age at index surgery was 61.8 years (SD 6.9). Male gender (OR = 3.27, 95% CI = 2.59-4.13, p < 0.001), patient weight above 80 kg (OR = 3.55, 95% CI = 2.88-4.37, p < 0.001), age under 63 years (OR = 1.22, 95% CI = 1.01-1.49, p < 0.001), varus stem alignment (OR = 5.77, 95% CI = 3.83-8.7, p < 0.001), use of modular implants (OR = 1.95, 95% CI = 1.56-2.44, p < 0.01) and undergoing revision arthroplasty (OR = 3.33, 95% CI = 2.70-4.1, p < 0.001) were significant risk factors for prosthetic stem fracture. A risk window of 15 years post-surgery was identified. CONCLUSIONS: This review concludes that patient weight, younger age, male sex, varus stem alignment, revision arthroplasty and use of modular stems are significant risk factors for femoral stem fracture. Modifying these risk factors where possible may help reduce incidence of femoral stem fracture in at risk patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Femenino , Humanos , Masculino , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/cirugía , Fracturas del Fémur/epidemiología , Fracturas del Fémur/etiología , Prótesis de Cadera/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Falla de Prótesis , Factores de Riesgo
13.
Sci Rep ; 14(1): 8364, 2024 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600312

RESUMEN

This study retrospectively assessed radiographic outcomes and risk factors associated with non-union in femoral shaft fragmentary segmental fractures (AO/OTA 32C3) treated with reamed antegrade intra-medullary nailing. Radiological outcomes, including union and alignment, were evaluated. The risk factors for non-union were investigated, including demographics and treatment-related characteristics, such as the number of interlocking screws, segmentation length, main third fragment length, distance of the main third fragment, width ratio and exposed nail length in one cortex from immediate post-operative radiographs. Multivariate logistic regression was used for statistical analysis. Among 2295 femoral shaft fracture patients from three level-1 trauma centers, 51 met the inclusion criteria. The radiological union was achieved in 37 patients (73%) with a mean union time of 10.7 ± 4.8 months. The acceptable axial alignment was observed in 30 patients (59%). Multiple logistic regression analysis identified only exposed nail length as a significant risk factor for non-union (odds ratio: 1.599, p = 0.003) and the cut-off value was 19.1 mm (sensitivity, 0.786; specificity, 0.811). The study revealed high rates of non-union (27%) and malalignment (41%). Therefore, patients who underwent intramedullary nailing with an exposed nail length greater than 19.1 mm or about twice the nail diameter should be cautioned of the potential non-union.


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/efectos adversos , Estudios Retrospectivos , Clavos Ortopédicos/efectos adversos , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Radiografía , Resultado del Tratamiento , Curación de Fractura
14.
BMC Musculoskelet Disord ; 25(1): 271, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589829

RESUMEN

BACKGROUND: Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. METHODS: Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) - SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. RESULTS: Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. CONCLUSIONS: A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.


Asunto(s)
Tornillos Óseos , Fracturas del Fémur , Humanos , Tornillos Óseos/efectos adversos , Fenómenos Biomecánicos , Fijadores Internos , Fijación Interna de Fracturas , Fracturas del Fémur/etiología , Peso Corporal
15.
J Pediatr Orthop ; 44(5): e439-e445, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38506233

RESUMEN

BACKGROUND: Although stress fractures of the distal femur are rare, symptoms can overlap with other peri-articular knee pathology, delaying diagnosis. Untreated stress fractures have the potential to progress into completed fractures with a higher likelihood for requiring surgery and longer recovery times in otherwise healthy adolescents and young adults. This case series represents the largest cohort of adolescent athletes with distal femoral stress fractures who presented with activity-related knee pain. METHODS: Patients treated nonoperatively and operatively for metaphyseal distal femur stress fractures at a tertiary referral center over a four-year period were retrospectively identified from the medical record. RESULTS: Eight patients (mean age 16.8 y; range 14 to 22 y; 87.5% male; mean body mass index [BMI] 20.9) with a total of 10 distal femur stress fractures were identified. All patients were involved in competitive sports or military training. There was an average of 3.8 encounters with a medical provider between presentation with activity-related knee pain and diagnosis with distal femur stress fracture. All except 1 patient (87.5%) were initially incorrectly diagnosed with another type of peri-articular knee pathology. Six stress fractures (60%) were treated conservatively with protected weight bearing, activity modification, and gradual return to activity. Four completed stress fractures (40%) required operative fixation-3 healed uneventfully, while 1 had an asymptomatic delayed union. Vitamin D insufficiency (<30 ng/mL) was identified in 7 of 8 patients (87.5%) and 3 patients (37.5%) had an underweight BMI (<18.5). The mean clinical follow-up was 13.1 weeks (range, 2.8 to 32.0 wk). CONCLUSIONS: High clinical suspicion for distal femoral stress fractures is needed to avoid misdiagnosis or delayed diagnosis in young, active individuals with activity-related knee pain refractory to conservative management. In this patient population, activity-related knee pain recalcitrant to activity modification, rest, and physical therapy warrants further workup with magnetic resonance imaging and orthopaedic evaluation. Though rare, misdiagnosis can result in catastrophic fractures with prolonged rehabilitation needs. An open line of communication and streamlined access for referral between primary care providers and orthopaedic surgeons is critical in preventing misdiagnosis and delayed treatment. Furthermore, the treatment of concomitant metabolic disorders and nutritional deficiency should not be neglected when treating distal femoral stress fractures. LEVEL OF EVIDENCE: Level-IV (case series).


Asunto(s)
Fracturas del Fémur , Fracturas por Estrés , Humanos , Masculino , Adolescente , Adulto Joven , Femenino , Fracturas por Estrés/epidemiología , Fracturas por Estrés/cirugía , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/métodos , Estudios Retrospectivos , Atletas , Dolor/etiología , Resultado del Tratamiento
16.
J Long Term Eff Med Implants ; 34(3): 13-17, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38505888

RESUMEN

Postoperative late-onset infections more than 1 year after intramedullary nail surgery for femoral shaft fractures are very rare. We show an extremely rare case of developed late-onset infection 27 years after surgery, report on risk factors for late-onset infection, and infer why the infection occurred.


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/efectos adversos , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Complicaciones Posoperatorias/etiología , Clavos Ortopédicos/efectos adversos , Factores de Riesgo , Curación de Fractura
17.
Int Orthop ; 48(6): 1645-1655, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38386087

RESUMEN

PURPOSE: This study explored the incidence of IRCs used in the procedures of the femur in children with osteogenesis imperfecta (OI) and investigated the independent risk factors of IRCs. METHODS: Three hundred eight-eight cases of surgical data about children with OI were included, who were treated with plate, elastic nail, Kirschner wire and telescopic rod. The choice of different procedures depended on the age of children, the status of femur and the availability of devices. Patient demographics and major IRCs were recorded to compare the outcomes of the four procedures. Then, Cox proportional hazard regression was used to analyse the independent risk factors of IRC, and subgroup analysis was applied to further verify the above results. RESULTS: The total incidence of IRC in the four groups was 90.1% (191/212) for plate, 96.8% (30/31) for Kirschner wire, 87.7% (57/65) for elastic nail and 30.0% (24/80) for telescopic rod. The incidence of IRC in the telescopic rod was lower than that in plate, elastic nail and Kirschner wire (P < 0.001). Cox proportional hazard regression analysis confirmed that procedure was the independent risk factor of IRC (HR, 0.191; 95% CI, 0.126-0.288; P < 0.001), fracture (HR, 0.193; 95% CI, 0.109-0.344; P < 0.001) and deformity (HR, 0.086; 95% CI, 0.027-0.272; P < 0.001). In addition, age of surgery was the independent risk factor of fracture (HR, 0.916; 95% CI, 0.882-0.952; P < 0.001) and deformity (HR, 1.052; 95% CI, 1.008-1.098; P = 0.019). Subgroup analysis confirmed that age of surgery, gender, classification, preoperative state and angle did not affect the effect of telescopic rod on reducing the risk of IRCs. CONCLUSIONS: In our cohort, lower incidence of IRCs was observed in telescopic rod group compared with plate, Kirschner wire and elastic nail. Procedure and age of surgery were independent risk factors of fracture. Likewise, procedure and age of surgery were independent risk factors of deformity, and procedure was independent risk factors of IRC.


Asunto(s)
Clavos Ortopédicos , Fracturas del Fémur , Osteogénesis Imperfecta , Humanos , Osteogénesis Imperfecta/complicaciones , Osteogénesis Imperfecta/cirugía , Masculino , Femenino , Niño , Incidencia , Preescolar , Factores de Riesgo , Clavos Ortopédicos/efectos adversos , Fracturas del Fémur/cirugía , Fracturas del Fémur/epidemiología , Fracturas del Fémur/etiología , Fémur/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Placas Óseas/efectos adversos , Lactante , Adolescente , Hilos Ortopédicos , Modelos de Riesgos Proporcionales
18.
Clin Orthop Relat Res ; 482(8): 1485-1493, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38323976

RESUMEN

BACKGROUND: Periprosthetic femur fracture is a known complication after THA. The associated risk of cementless femoral component design for periprosthetic femur fracture in a registry population of patients older than 65 years has yet to be clearly identified. QUESTIONS/PURPOSES: (1) Is femoral stem geometry associated with the risk of periprosthetic femur fracture after cementless THA? (2) Is the presence or absence of a collar on cementless femoral implant designs associated with the risk of periprosthetic femur fracture after THA? METHODS: We analyzed American Joint Replacement Registry data from 2012 to March 2020. Unique to this registry is the high use of cementless femoral stems in patients 65 years and older. We identified 266,040 primary cementless THAs during the study period in patients with a diagnosis of osteoarthritis and surgeries linked to supplemental Centers for Medicare and Medicaid data where available. Patient demographics, procedure dates, and reoperation for periprosthetic femur fracture with revision or open reduction and internal fixation were recorded. The main analysis was performed comparing the Kheir and Chen classification: 42% (112,231 of 266,040) were single-wedge, 22% (57,758 of 266,040) were double-wedge, and 24% (62,983 of 266,040) were gradual taper/metadiaphyseal-filling cementless femoral components, which yielded a total of 232,972 primary cementless THAs. An additional analysis compared cementless stems with collars (20% [47,376 of 232,972]) with those with collarless designs (80% [185,596 of 232,972]). A Cox proportional hazard regression analysis with the competing risk of death was used to evaluate the association of design and fracture risk while adjusting for potential confounders. RESULTS: After controlling for the potentially confounding variables of age, sex, geographic region, osteoporosis or osteopenia diagnosis, hospital volume, and the competing risk of death, we found that compared with gradual taper/metadiaphyseal-filling stems, single-wedge designs were associated with a greater risk of periprosthetic femur fracture (HR 2.9 [95% confidence interval (CI) 2.2 to 3.9]; p < 0. 001). Compared with gradual taper/metadiaphyseal-filling stems, double-wedge designs showed an increased risk of periprosthetic femur fracture (HR 3.0 [95% CI 2.2 to 4.0]; p < 0. 001). Collarless stems showed an increased risk of periprosthetic fracture compared with collared stems (HR 7.8 [95% CI 4.1 to 15]; p < 0. 001). CONCLUSION: If cementless femoral fixation is used for THA in patients 65 years or older, surgeons should consider using gradual taper/metadiaphyseal-filling and collared stem designs because they are associated with a lower risk of periprosthetic femur fracture. Future investigations should compare gradual taper/metadiaphyseal-filling and collared cementless designs with cemented fixation in this population. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Diseño de Prótesis , Sistema de Registros , Humanos , Anciano , Fracturas Periprotésicas/cirugía , Fracturas Periprotésicas/etiología , Femenino , Masculino , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/efectos adversos , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Factores de Riesgo , Anciano de 80 o más Años , Reoperación/estadística & datos numéricos , Estados Unidos/epidemiología
19.
Bone Joint J ; 106-B(3 Supple A): 115-120, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38423098

RESUMEN

Aims: Periprosthetic femoral fracture (PPF) is a major complication following total hip arthroplasty (THA). Uncemented femoral components are widely preferred in primary THA, but are associated with higher PPF risk than cemented components. Collared components have reduced PPF rates following uncemented primary THA compared to collarless components, while maintaining similar prosthetic designs. The purpose of this study was to analyze PPF rate between collarless and collared component designs in a consecutive cohort of posterior approach THAs performed by two high-volume surgeons. Methods: This retrospective series included 1,888 uncemented primary THAs using the posterior approach performed by two surgeons (PKS, JMV) from January 2016 to December 2022. Both surgeons switched from collarless to collared components in mid-2020, which was the only change in surgical practice. Data related to component design, PPF rate, and requirement for revision surgery were collected. A total of 1,123 patients (59.5%) received a collarless femoral component and 765 (40.5%) received a collared component. PPFs were identified using medical records and radiological imaging. Fracture rates between collared and collarless components were analyzed. Power analysis confirmed 80% power of the sample to detect a significant difference in PPF rates, and a Fisher's exact test was performed to determine an association between collared and collarless component use on PPF rates. Results: Overall, 17 PPFs occurred (0.9%). There were 16 fractures out of 1,123 collarless femoral components (1.42%) and one fracture out of 765 collared components (0.13%; p = 0.002). The majority of fractures (n = 14; 82.4%) occurred within 90 days of primary THA. There were ten reoperations for PPF with collarless components (0.89%) and one reoperation with a collared component (0.13%; p = 0.034). Conclusion: Collared femoral components were associated with significant decreases in PPF rate and reoperation rate for PPF compared to collarless components in uncemented primary THA. Future studies should investigate whether new-generation collared components reduce PPF rates with longer-term follow-up.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/prevención & control , Fracturas Periprotésicas/cirugía , Estudios Retrospectivos , Diseño de Prótesis , Fracturas del Fémur/etiología , Fracturas del Fémur/prevención & control , Fracturas del Fémur/cirugía
20.
Bone Joint J ; 106-B(3 Supple A): 67-73, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38423110

RESUMEN

Aims: The aim of this retrospective study was to assess the incidence of early periprosthetic femoral fracture (PFF) associated with Charnley-Kerboull (CK) femoral components cemented according to the 'French paradox' principles through the Hueter anterior approach (HAA) in patients older than 70 years. Methods: From a prospectively collected database, all short CK femoral components implanted consecutively from January 2018 to May 2022 through the HAA in patients older than 70 years were included. Exclusion criteria were age below 70 years, use of cementless femoral component, and approaches other than the HAA. A total of 416 short CK prostheses used by 25 surgeons with various levels of experience were included. All patients had a minimum of one-year follow-up, with a mean of 2.6 years (SD 1.1). The mean age was 77.4 years (70 to 95) and the mean BMI was 25.3 kg/m2 (18.4 to 43). Femoral anatomy was classified according to Dorr. The measured parameters included canal flare index, morphological cortical index, canal-calcar ratio, ilium-ischial ratio, and anterior superior iliac spine to greater trochanter (GT) distance. Results: Among the 416 THAs, two PFFs (0.48% (95% confidence interval 0.13 to 1.74)) were observed, including one Vancouver type B2 fracture 24 days postoperatively and one intraoperative Vancouver type B1 fracture. Valgus malalignment and higher canal bone ratio were found to be associated with PFF. Conclusion: This study demonstrated that short CK femoral components cemented according to the French paradox were associated with a low rate of early PFF (0.48%) in patients aged over 70 years. Longer follow-up is warranted to further evaluate the rate of fracture that may occur during the bone remodelling process and with time.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fracturas del Fémur/epidemiología , Fémur/cirugía , Fracturas Periprotésicas/cirugía , Reoperación/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA