Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 592
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 735, 2024 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-39277709

RESUMEN

PURPOSE: This study aimed to compare the clinical outcomes and differences in biomechanical characteristics between the femoral neck system (FNS) and cannulated cancellous screws (CCSs) in the treatment of femoral neck fractures. METHODS: This study retrospectively analysed a cohort of 38 registered cases of femoral neck fractures treated surgically with either the FNS (n = 17) or CCSs (n = 21) between January 2020 and December 2023. Indicators such as fluoroscopy frequency, length of hospital stay, and fracture healing time were compared between the two groups. Functional status was evaluated via the Harris hip score (HHS) and visual analogue scale (VAS), whereas prognosis was assessed based on changes in the neck shaft angle and femoral neck shortening. Additionally, six sets of femoral neck fracture models were developed based on Pauwels angles of 30°, 40°, 50°, 60°, 70°, and 80°. Two experimental groups, FNS and CCS, were established, and a joint reaction force of 1800 N was applied to the proximal femur. The displacement, stress, and stiffness of the components of interest in the different models were tested and compared. RESULTS: The distributions of all the baseline characteristics were similar between the two groups (p > 0.05). The FNS group presented significantly shorter fluoroscopy frequency, length of hospital stay, and fracture healing time (p < 0.05). Harris and VAS scores were higher in the FNS group than in the CCS group (p < 0.05). Postoperative changes in the neck shaft angle and femoral neck shortening were significantly lower in the FNS group than in the CCS group (p < 0.05). The results of the finite element analysis indicated that the maximum stress on the femoral head and varus angle were generally lower in the FNS group than in the CCS group and that the maximum displacement of the femoral head and FNS was generally lower in the FNS group than in the CCS group. However, the superiority of FNS over CCS decreased with increasing Pauwels angle. Additionally, the effectiveness of FNS in limiting displacement of the femoral neck upper wall was not as favourable as that of CCS. CONCLUSIONS: The treatment of femoral neck fractures with FNS is superior and contributes to improved hip joint function. Biomechanical research has confirmed its structural stability and advantages in resisting femoral head varus. However, challenges to its fixation efficacy persist, particularly at higher Pauwels angles.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral , Fijación Interna de Fracturas , Humanos , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Fenómenos Biomecánicos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Curación de Fractura , Cuello Femoral/cirugía , Cuello Femoral/diagnóstico por imagen , Tiempo de Internación , Anciano de 80 o más Años
2.
BMC Musculoskelet Disord ; 25(1): 697, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39223520

RESUMEN

OBJECTIVE: There is currently a lack of in-depth comparative evaluation regarding the biomechanical properties of novel intramedullary nail devices in the treatment of basal femoral neck fractures (BFNF). This study aims to utilize finite element analysis to compare the performance differences of two novel devices with traditional PFNA and InterTan nails in the fixation of BFNF. METHODS: Based on a validated finite element model, this study constructed an accurate BFNF model and implanted four different intramedullary nail devices: PFNA, InterTan nail, PFBN (proximal femoral biomimetic nail), and NIS (novel intramedullary system). Under a vertical load of 2100N, the displacement and Von Mises stress (VMS) distribution of each group of models were evaluated through simulation testing. RESULTS: Under a load of 2100N, the PFBN device exhibited the best performance in terms of displacement and peak stress, while PFNA performed poorly. The peak displacement of the NIS device was lower than that of PFNA and InterTan nails, while the peak stress of the InterTan nail was lower than that of PFNA and NIS. CONCLUSION: The PFBN device demonstrates stronger load-bearing and shear-resistant properties in the treatment of BFNF, and the NIS device also shows significant improvement in stability. Therefore, both the PFBN and NIS devices are reliable internal fixation techniques for the treatment of CFIFs, with potential clinical application prospects.


Asunto(s)
Clavos Ortopédicos , Fracturas del Cuello Femoral , Análisis de Elementos Finitos , Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Fenómenos Biomecánicos/fisiología , Estrés Mecánico , Soporte de Peso
3.
Sci Rep ; 14(1): 19356, 2024 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-39169075

RESUMEN

This study aims to evaluate the biomechanical performance of the Gamma 3 nail with an anti-rotation screw (GNS) and compare it to two established gold-standard methods for treating unstable femoral neck fractures (UFNFs). Synthetic bone models were prepared with Pauwels' type III osteotomy and an additional posterior wedge. Three different implant configurations were tested: three cannulated crews (3CS) in an inverted triangle configuration, a dynamic hip screw with an anti-rotation screw (DHSS), and GNS. Non-destructive cyclic axial loading was applied at 7° adduction, with 1000 cycles ranging from 100 to 1000 N. Subsequently, a construct failure test was conducted using progressive axial compression, and fracture reduction loss was recorded. The average axial stiffness was 321 ± 52 N/mm for 3CS, 430 ± 71 N/mm for DHSS, and 519 ± 104 N/mm for GNS. The average ultimate failure loads were 2699.3 N for 3CS, 3427.1 N for DHSS, and 3758.9 N for GNS. GNS demonstrated significantly greater axial stiffness compared to the other two groups (P < 0.05). Both DHSS and GNS exhibited similar failure loading, which were greater than those of 3CS (P < 0.05). GNS offers the advantages of a minimally invasive and intramedullary implant with comparable stability to the DHSS system. Moreover, GNS demonstrated superior biomechanical performance compared to 3 CS configuration.


Asunto(s)
Clavos Ortopédicos , Tornillos Óseos , Fracturas del Cuello Femoral , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Humanos , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación
4.
Injury ; 55(10): 111717, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39002322

RESUMEN

INTRODUCTION: Several internal fixation devices are available for treating Pauwels type I, II and III femoral neck fractures. The present study compared various fixation implants for all Pauwels fracture types using a CT-based subject-specific finite element model of the femur and determined the most effective implant for each fracture type. MATERIALS AND METHODS: The analysis included four different configurations of cannulated screw models, Femoral Neck System, Dynamic Hip Screw and Dynamic Condylar Screw (with and without anti-rotational screw). Ti-alloy was considered as the implant material. Heterogeneous bone material property was assigned based on CT grey value. Frictional contact was assumed in the contact interfaces. Peak loading corresponding to normal walking and stair-climbing were considered. Equivalent strain in bone, equivalent stress in the implants, femoral head deformation and rotation, micromotion in the contact interfaces, and strain-shielding in bone were evaluated for each implanted model. RESULTS: Stresses generated in the implants were within the yield limit of the implant material. In Pauwels I and II, the micromotion predicted at the contact regions in all the implanted models was within 100 µm, which is suitable for bone integration. However, in Pauwels III fracture, most of the implanted models other than DHS with AR-screw model exhibited micromotion of more than 150 µm in the contact regions, which is expected to inhibit bone growth. CONCLUSIONS: The DHS with AR-screw implanted model was identified as the most effective in treating Pauwels I and III fractures. However, for Pauwels type II, DCS with an AR-screw implant was deemed superior to the other configurations.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral , Análisis de Elementos Finitos , Fijación Interna de Fracturas , Humanos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Fenómenos Biomecánicos , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Estrés Mecánico , Soporte de Peso/fisiología , Ensayo de Materiales
5.
Sci Rep ; 14(1): 15519, 2024 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-38969693

RESUMEN

The selection of implants for fixing unstable femoral neck fractures (FNF) remains contentious. This study employs finite element analysis to examine the biomechanics of treating Pauwels type III femoral neck fractures using cannulated compression screws (3CS), biplane double-supported screw fixation (BDSF), and the femoral neck system (FNS). A three-dimensional model of the proximal femur was developed using computed tomography scans. Fracture models of the femoral neck were created with 3CS, BDSF, and FNS fixations. Von Mises stress on the proximal femur, fracture ends, internal fixators, and model displacements were assessed and compared across the three fixation methods (3CS, BDSF, and FNS) during the heel strike of normal walking. The maximum Von Mises stress in the proximal fragment was significantly higher with 3CS fixation compared to BDSF and FNS fixations (120.45 MPa vs. 82.44 MPa and 84.54 MPa, respectively). Regarding Von Mises stress distribution at the fracture ends, the highest stress in the 3CS group was 57.32 MPa, while BDSF and FNS groups showed 51.39 MPa and 49.23 MPa, respectively. Concerning implant stress, the FNS model exhibited greater Von Mises stress compared to the 3CS and BDSF models (236.67 MPa vs. 134.86 MPa and 140.69 MPa, respectively). Moreover, BDSF displayed slightly lower total displacement than 3CS fixation (7.19 mm vs. 7.66 mm), but slightly higher displacement than FNS (7.19 mm vs. 7.03 mm). This study concludes that BDSF outperforms 3CS fixation in terms of biomechanical efficacy and demonstrates similar performance to the FNS approach. As a result, BDSF stands as a dependable alternative for treating Pauwels type III femoral neck fractures.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral , Análisis de Elementos Finitos , Fijación Interna de Fracturas , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Fijación Interna de Fracturas/métodos , Humanos , Fenómenos Biomecánicos , Estrés Mecánico , Tomografía Computarizada por Rayos X
6.
J Orthop Surg Res ; 19(1): 371, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38909252

RESUMEN

BACKGROUND: Basicervical femoral neck fracture is a rare proximal femur fracture with a high implant failure rate. Biomechanical comparisons between cephalomedullary nails (CMNs) and dynamic hip screws (DHSs) under torsion loading are lacking. This study compared the biomechanical performance of three fixations for basicervical femoral neck fractures under torsion load during early ambulation. METHODS: The biomechanical study models used three fixations: a DHS, a DHS with an anti-rotation screw, and a short CMN. Finite element analysis was used to simulate hip rotation with muscle forces related to leg swing applied to the femur. The equivalent von Mises stress (EQV) on fixation, fragment displacement, and strain energy density at the proximal cancellous bone were monitored for fixation stability. RESULTS: The EQV of the short CMN construct (304.63 MPa) was comparable to that of the titanium DHS construct (293.39 MPa) and greater than that of the titanium DHS with an anti-rotation screw construct (200.94 MPa). The proximal fragment displacement in the short CMN construct was approximately 0.13 mm, the greatest among the constructs. The risk of screw cutout for the lag screw in short CMNs was 3.1-5.8 times greater than that for DHSs and DHSs with anti-rotation screw constructs. CONCLUSIONS: Titanium DHS combined with an anti-rotation screw provided lower fragment displacement, stress, and strain energy density in the femoral head than the other fixations under torsion load. Basicervical femoral neck fracture treated with CMNs may increase the risk of lag screw cutout.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Humanos , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Clavos Ortopédicos , Torsión Mecánica
7.
Injury ; 55(8): 111640, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38823097

RESUMEN

INTRODUCTION: Reconstruction nails are commonly used to treat proximal femur fractures, with cephalic screw placement for femoral neck "prophylaxis" becoming standard practice. These implants are traditionally introduced through piriformis fossa (PF) or greater trochanter (GT) entry portals. A third "central collinear" (CC) portal has been proposed that allows entry along the femoral anatomic axis and central placement of cephalic screws. The present study aimed to quantify and compare the CC portal femoral neck strength with the two traditional (PF and GT) entry portals. MATERIALS AND METHODS: Eighteen cadaveric femur specimens (nine matched pairs) were divided into three groups using a balanced incomplete block design to control for variations in age and sex: (1) GT, (2) CC, and (3) PF entry points. Specimens and implants were cut to a standard length and instrumented with straight or valgus bend nails of appropriate laterality and two cephalic screws. Specimens were mounted on a custom jig replicating load distribution along the mechanical axis. A 100 N compressive preload was applied to the femoral head, followed by loading to failure at a rate of 10 mm/s until fracture, indicated by 30 % drop in axial force. RESULTS: THE THREE ENTRY POINTS DID NOT DIFFER IN LOAD-TO-FAILURE: GT (6378.7 ± 1494.9 N), P (6912.4 ± 4924.1 N) and CC (7044.2 ± 2911.4 N) (P = 0.948) or maximum displacement, stiffness, and toughness. Most PF specimens failed at the basicervical neck, whereas most GT specimens failed at the subcapital neck; these differences were not significant. CC specimens failed evenly split between subcapital and basicervical. CONCLUSION: There were no significant difference in femoral neck load-to-failure after placement of a reconstruction nail through a CC entry portal when compared to both GT and PF entry. Clinically, this suggests the CC entry portal is a viable option when clinical considerations warrant its use.


Asunto(s)
Clavos Ortopédicos , Tornillos Óseos , Cadáver , Fracturas del Cuello Femoral , Fijación Intramedular de Fracturas , Humanos , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Fenómenos Biomecánicos , Masculino , Femenino , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Anciano , Anciano de 80 o más Años , Persona de Mediana Edad , Soporte de Peso/fisiología
8.
Injury ; 55(6): 111564, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38640596

RESUMEN

BACKGROUND: The purpose of this study was to compare the outcomes of femoral neck shortening between the femoral neck system (FNS) and the cannulated cancellous screws (CCS) for displaced femoral neck fractures in young adults PATIENTS AND METHODS: In this retrospective analysis, 225 patients aged 18-65 years with displaced femoral neck fracture were divided into two groups according to internal fixation: 135 patients in the FNS group and 90 patients in the CCS group. The length of hospital stay, duration of surgery, intraoperative blood loss, quality of reduction, extent of femoral neck shortening, incidence of femoral neck shortening, femoral neck shortening at each follow-up visit, Harris hip score (HHS), reoperation, and complications were compared between the two groups. RESULTS: The median follow-up time was 28.2 (26.0, 31.2) months in the FNS group and 30.2 (26.3, 34.7) months in the CCS group. The follow-up time, age, sex distribution, body mass index (BMI), mechanism of injury, injured side, length of hospital stay, time from injury to surgery, and fracture classification were similar between the groups. Duration of surgery was longer in the FNS group (65.0 (55.0, 87.0) min versus 55.0 (50.0, 65.0) min, P<0.001); intraoperative blood loss was greater in the FNS group (50.0 (20.0, 60.0) ml versus 20.0 (10.0, 35.0) ml, P<0.001). Femoral neck shortening was 2.4 (1.0, 4.5) mm in the FNS group versus 0.6 (0.0, 2.6) mm in the CCS group at 1 month postoperatively (P<0.001); 3.7 (1.8, 6.4) mm in the FNS group versus 1.2 (0.6, 3.8) mm in the CCS group at 3 months (P<0.001); 4.1(2.4, 7.7) mm in the FNS group versus 2.3 (1.1, 4.4) mm in the CCS group at 6 months (P<0.001); 4.2 (2.6, 7.7) mm in the FNS group versus 2.6 (1.3, 4.6) mm in the CCS group at 12 months (P<0.001); and 4.5 (2.8, 8.0) mm in the FNS group versus 2.8 (1.5, 4.8) mm in the CCS group at 18 months (P<0.001). The two groups showed no significant differences in HHS, reoperation, and reduction quality. CONCLUSION: Compared to CCS, FNS is deficient in preventing femoral neck shortening. Future research should focus on improving FNS in terms of preventing femoral neck shortening.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral , Fijación Interna de Fracturas , Tiempo de Internación , Humanos , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Masculino , Femenino , Fijación Interna de Fracturas/métodos , Estudios Retrospectivos , Adulto , Persona de Mediana Edad , Adulto Joven , Resultado del Tratamiento , Tiempo de Internación/estadística & datos numéricos , Adolescente , Reoperación/estadística & datos numéricos , Estudios de Seguimiento , Curación de Fractura/fisiología , Complicaciones Posoperatorias/prevención & control , Tempo Operativo , Cuello Femoral/cirugía , Pérdida de Sangre Quirúrgica
9.
PLoS One ; 17(2): e0263475, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35213546

RESUMEN

INTRODUCTION: American orthopaedists are increasingly seeking fellowship sub-specialization. One proposed benefit of fellowship training is decrease in complications, however, few studies have investigated the rates of medical and surgical complications for hip fracture patients between orthopedists from different fellowship backgrounds. This study aims to investigate the effect of fellowship training and case volume on medical and surgical outcomes of patient following hip fracture surgical intervention. METHODS: 1999-2016 American Board of Orthopedic Surgery (ABOS) Part II Examination Case List data were used to assess patients treated by trauma or adult reconstruction fellowship-trained orthopedists versus all-other orthopaedists. Rates of surgeon-reported medical and surgical adverse events were compared between the three surgeon cohorts. Using binary multivariate logistic regression to control of demographic factors, independent factors were evaluated for their effect on surgical complications. RESULTS: Data from 73,427 patients were assessed. An increasing number of hip fractures are being treated by trauma fellowship trained surgeons (9.43% in 1999-2004 to 60.92% in 2011-2016). In multivariate analysis, there was no significant difference in type of fellowship, however, surgeons with increased case volume saw significantly decreased odds of complications (16-30 cases: OR = 0.91; 95% CI: 0.85-0.97; p = 0.003; 31+ cases: OR = 0.68; 95% CI: 0.61-0.76; p<0.001). Femoral neck hip fractures were associated with increased odds of surgical complications. DISCUSSION: Despite minor differences in incidence of surgical complications between different fellowship trained orthopaedists, there is no major difference in overall risk of surgical complications for hip fracture patients based on fellowship status of early orthopaedic surgeons. However, case volume does significantly decrease the risk of surgical complications among these patients and may stand as a proxy for fellowship training. Fellows required to take hip fracture call as part of their training regardless of fellowship status exhibited decreased complication risk for hip fracture patients, thus highlighting the importance of additional training.


Asunto(s)
Fracturas del Cuello Femoral/cirugía , Fracturas de Cadera/cirugía , Procedimientos Ortopédicos/efectos adversos , Huesos Pélvicos/cirugía , Anciano , Anciano de 80 o más Años , Bases de Datos Factuales , Femenino , Fracturas del Cuello Femoral/fisiopatología , Servicios de Salud para Ancianos , Fracturas de Cadera/epidemiología , Fracturas de Cadera/fisiopatología , Humanos , Masculino , Ortopedia/normas , Huesos Pélvicos/fisiopatología , Cirujanos/estadística & datos numéricos , Estados Unidos/epidemiología
10.
Sci Rep ; 12(1): 325, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-35013408

RESUMEN

Closed reduction and internal fixation with three cannulated compression screws is a common method for treating femoral neck fractures in young and middle-aged patients. Protocols including the inverted triangle configuration and dispersion of the screws still needed further supports. The purpose of this study was to explore a novel oblique triangle configuration (OTC) of three screws in fixing femoral neck fractures based on the morphology of the femoral neck isthmus (FNI). The computer-aided design modules were used to explore the ideal spatial configuration with largest triangle by three parallel screws. A univariate evaluation model was established based on the oval-like cross-section of the FNI. When the three screws were positioned by the OTC, Inverted Equilateral Triangle Configuration (IETC), and the Maximum Area Inverted Isosceles Triangle Configuration (MA-IITC) respectively, the proportion of area and circumference in the cross-section of FNI and the changing trend of proportion were compared under various torsion angles, eccentricity, and cross-sectional area of FNI. The area and circumference ratios of the parallel screws using the OTC method were significantly higher than in the IETC and MA-IITC groups. In the univariate evaluation model, the OTC area ratio and circumference ratio remained stable under the different femoral neck torsion angles, FNI cross-sectional area, and eccentricity. The OTC method provided an ideal spatial configuration for the FNA fixation with the largest area using three parallel screws. The position of the posterior screw was also away from the metaphyseal artery, potentially reducing the possibility of vascular injury and screw penetrating.


Asunto(s)
Tornillos Óseos , Diseño Asistido por Computadora , Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/instrumentación , Diseño de Prótesis , Fenómenos Biomecánicos , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/fisiopatología , Fijación Interna de Fracturas/efectos adversos , Humanos , Estrés Mecánico
11.
Eur J Med Res ; 26(1): 59, 2021 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-34167592

RESUMEN

BACKGROUND: Femoral neck shortening can occur in young patients receiving internal fixation for Pauwels type II femoral neck fracture. The risk factors for neck shortening, which can affect hip function, are not clear. This study aimed to retrospectively identify risk factors for neck shortening after internal fixation with parallel partially threaded cannulated cancellous screws (FPTCS) for Pauwels type II femoral neck fracture in relatively young patients. METHODS: Clinical data from 122 cases with Pauwels type II femoral neck fracture from February 2014 to February 2019 were reviewed and analyzed, and causes of neck shortening were statistically analyzed. And the Chi-squared test or Fisher's exact test was used to compare indicators. Multivariate analysis was conducted with non-conditional logistic regression analysis. RESULTS: Statistically significant differences were found in age, sex, BMD, BMI, fracture type, posterior medial cortex comminution, and reduction quality between patients with femoral neck shortening and those without femoral neck shortening. Logistic regression analysis showed that fracture type, posterior medial cortex comminution, and reduction quality were the main risk factors for neck shortening. CONCLUSION: Fracture type, posterior medial cortex comminution, and reduction quality can be used as important reference indexes to predict the possibility of neck shortening after internal fixation with FPTCS for Pauwels type II femoral neck fracture in young patients. BMD and BMI may be also risk factors.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/efectos adversos , Curación de Fractura , Complicaciones Posoperatorias/epidemiología , Adolescente , Adulto , China/epidemiología , Femenino , Fracturas del Cuello Femoral/diagnóstico , Fracturas del Cuello Femoral/fisiopatología , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Adulto Joven
12.
Curr Pain Headache Rep ; 25(4): 22, 2021 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-33694008

RESUMEN

PURPOSE OF REVIEW: Over 300,000 patients are hospitalized annually following hip fractures in the USA. Many patients experienced inadequate analgesia. We will review the perioperative effects of the fascia iliaca compartment block (FICB) in hip fracture patients. RECENT FINDINGS: FICB by injecting local anesthetics beneath the fascia iliaca results in significant pain relief in hip fractures. Neuropathies and vascular injuries are almost unlikely. Single-shot FICB is faster to place, yet providing about 8 h of analgesia when bupivacaine is used. Continuous FICB provides prolonged titratable analgesia, improved patient satisfaction, and leads to faster hospital discharge. FICB reduces opioid consumption, decreases morbidity and mortality, reduces hospital stay, reduces delirium, and improves satisfaction. FICB should form part of a multimodal analgesic regime, in the context of a multidisciplinary approach to the management of hip fracture patients. More clinical investigations are needed to validate the long-term outcome benefits of FICB in hip fracture patients.


Asunto(s)
Dolor Agudo/tratamiento farmacológico , Anestesia de Conducción/métodos , Anestésicos Locales/uso terapéutico , Fracturas de Cadera/cirugía , Manejo del Dolor/métodos , Dolor Postoperatorio/tratamiento farmacológico , Atención Perioperativa/métodos , Dolor Agudo/fisiopatología , Analgésicos Opioides/uso terapéutico , Delirio/epidemiología , Fascia , Fracturas del Cuello Femoral/fisiopatología , Fracturas del Cuello Femoral/cirugía , Nervio Femoral , Fracturas de Cadera/fisiopatología , Humanos , Tiempo de Internación/estadística & datos numéricos , Nervio Obturador , Satisfacción del Paciente , Complicaciones Posoperatorias/epidemiología , Músculos Psoas
13.
Clin Transl Sci ; 14(4): 1452-1463, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33650259

RESUMEN

Decline of bone mineral density (BMD) during menopause is related to increased risk of fractures in postmenopausal women, however, this relationship in premenopausal women has not been established. To quantify this relationship, real-world data (RWD) from the National Health and Nutrition Examination Survey (NHANES), and longitudinal data from the elagolix phase III clinical trials were modeled across a wide age range, and covariates were evaluated. The natural changes in femoral neck BMD (FN-BMD) were well-described by a bi-exponential relationship with first-order BMD formation (k1 ) and resorption (k2 ) rate constants. Body mass index (BMI) and race (i.e., Black) were significant predictors indicating that patients with high BMI or Black race experience a relatively lower BMD loss. Simulations suggest that untreated premenopausal women with uterine fibroids (UFs) from elagolix phase III clinical trials (median age 43 years [minimum 25-maximum 53]) lose 0.6% FN-BMD each year up to menopausal age. For clinical relevance, the epidemiological FRAX model was informed by the simulation results to predict the 10-year risk of major osteoporotic fracture (MOF). Premenopausal women with UFs, who received placebo only in the elagolix phase III trials, have a projected FN-BMD of 0.975 g/cm2 at menopause, associated with a 10-year risk of MOF of 2.3%. Integration of modeling, RWD, and clinical trials data provides a quantitative framework for projecting long-term postmenopausal risk of fractures, based on natural history of BMD changes in premenopausal women. This framework enables quantitative evaluation of the future risk of MOF for women receiving medical therapies (i.e., GnRH modulators) that adversely affect BMD.


Asunto(s)
Densidad Ósea/fisiología , Fracturas del Cuello Femoral/epidemiología , Osteoporosis/complicaciones , Fracturas Osteoporóticas/epidemiología , Premenopausia/fisiología , Adulto , Ensayos Clínicos Fase III como Asunto , Femenino , Fracturas del Cuello Femoral/etiología , Fracturas del Cuello Femoral/fisiopatología , Cuello Femoral/fisiopatología , Humanos , Estudios Longitudinales , Persona de Mediana Edad , Modelos Biológicos , Encuestas Nutricionales/estadística & datos numéricos , Osteoporosis/fisiopatología , Fracturas Osteoporóticas/etiología , Fracturas Osteoporóticas/fisiopatología , Medición de Riesgo/métodos , Medición de Riesgo/estadística & datos numéricos
14.
Clin Orthop Relat Res ; 479(1): 72-81, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876424

RESUMEN

BACKGROUND: THA is a reasonable surgical option for some patients with fragility fractures of the femoral neck, but it has the risk of prosthesis dislocation. The prosthesis combination that reduces the risk of dislocation and the rate of revision surgery is not known. QUESTIONS/PURPOSES: In patients receiving primary THA for a femoral neck fracture, does (1) the rate of all-cause revision or (2) the reason for revision and rate of revision for dislocation differ among THA with a standard head size, large head size, dual mobility (DM), or constrained liner? (3) Is there a difference in the revision risk when patients are stratified by age at the time of surgery? METHODS: Data were analyzed for 16,692 THAs performed to treat fractures of the femoral neck reported in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from January 2008 to December 2018, as this included the first use of DM prostheses. The AOANJRR includes information on more than 98% of arthroplasty procedures performed in Australia. Most patients were female (72%) and the mean age was 74 years ± 11. There were 8582 standard-head prostheses, 5820 large-head prostheses, 1778 DM prostheses, and 512 constrained prostheses identified. The cumulative percent revision (CPR) was determined for all causes as well as CPR for dislocation. The time to the first revision was described using Kaplan-Meier estimates of survivorship, with right censoring for death or closure of the database at the time of analysis. The unadjusted CPR was estimated each year of the first 10 years for standard heads, 10 years for large heads, 8 years for constrained liners, and 7 years for DM prostheses, with 95% confidence intervals using unadjusted pointwise Greenwood estimates. The results were adjusted for age, sex, femoral fixation, and head size where appropriate and were considered by age groups < 70 and ≥ 70 years. RESULTS: When adjusted for age, sex, femoral fixation and head size, there was no difference in the rate of all-cause revision at 7 years for any of the four groups. There was no difference in the rate of all-cause revision when patients were stratified by < 70 or ≥ 70 years of age. Dislocation was the most common reason for revision (32%). When analyzing revision for dislocation alone, large-head THA had a lower rate of revision for dislocation compared with standard head (HR 0.6 [95% CI 0.4 to 0.8]; p < 0.001) and DM prostheses had a lower rate of revision for dislocation than standard head for the first 3 months (HR 0.3 [95% CI 0.1 to 0.7]; p < 0.004) but not after this time point. CONCLUSION: The Australian registry shows that there is no difference in the rate of all-cause revision for standard-head, large-head, DM prostheses or constrained liner THA after femoral neck fractures for all patients or for patients stratified into younger than 70 years and at least 70 years of age groups. Dislocation is the most common cause of revision. Large-head prostheses are associated with a lower revision risk for dislocation and DM prostheses have a lower rate of revision for dislocation than standard heads for the first 3 months only. Surgeons treating a femoral neck fracture with THA might consider a large head size if the diameter of the acetabulum will allow it and a DM prosthesis if a large head size is not possible. The age, life expectancy and level of function of patients with femoral neck fractures minimizes the potential long-term consequences of these prostheses. The lack of significant differences in survival between most prosthesis combinations means surgeons should continue to look for factors beyond head size and prosthesis to minimize dislocation and revision surgery. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Fracturas del Cuello Femoral/cirugía , Luxación de la Cadera/cirugía , Prótesis de Cadera , Falla de Prótesis , Factores de Edad , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Australia , Femenino , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/fisiopatología , Curación de Fractura , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/etiología , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Reoperación , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
J Orthop Surg Res ; 15(1): 566, 2020 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-33256843

RESUMEN

BACKGROUND: A successful osseointegration of total hip arthroplasty (THA) relies on the interplay of implant surface and bone marrow microenvironment. This study was undertaken to investigate the impact of perioperative biochemical molecules (Ca2+, Mg2+, Zn2+, VD, PTH) on the bone marrow osteogenetic factors (BMP2, BMP7, Stro-1+ cells) in the metaphyseal region of the femoral head, and further on the bone mineral density (BMD) of Gruen R3. METHODS: Bone marrow aspirates were obtained from the discarded metaphysis region of the femoral head in 51 patients with THA. Flow cytometry was used to measure the Stro-1+ expressing cells. ELISA was used to measure the concentrations of bone morphologic proteins (BMP2 and BMP7) and the content of TRACP5b in serum. TRAP staining was used to detect the osteoclast activity in the hip joint. The perioperative concentrations of the biochemical molecules above were measured by radioimmunoassay. The BMD of Gruen zone R3 was examined at 6 months after THA, using dual-energy X-ray absorptiometry (DEXA). RESULTS: Our data demonstrated that the concentration of Ca2+ was positively correlated with BMP7 expression, and with the postoperative BMD of Gruen zone R3. However, the concentration of Mg2+ had little impact on the R3 BMD, although it was negatively correlated with the expression of BMP7. Osteoclast activity in hip joint tissue of patients with femoral neck fractures was increased. Compared with the patients before THA, the levels of TRACP5b in serum of patients after THA were decreased. The data also suggested that the other biochemical molecules, such as Zn2+, VD, and PTH, were not significantly correlated with any bone marrow osteogenetic factors (BMP2, BMP7, Stro-1+ cells). The postoperative R3 BMD of patients of different gender and age had no significant difference. CONCLUSIONS: These results indicate the local concentration of Ca2+ may be an indicator for the prognosis of THA patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Proteína Morfogenética Ósea 7/genética , Proteína Morfogenética Ósea 7/metabolismo , Calcio/metabolismo , Fracturas del Cuello Femoral/fisiopatología , Fracturas del Cuello Femoral/cirugía , Expresión Génica , Oseointegración/genética , Anciano , Antígenos de Superficie/metabolismo , Biomarcadores/sangre , Biomarcadores/metabolismo , Densidad Ósea , Células de la Médula Ósea/metabolismo , Femenino , Fracturas del Cuello Femoral/metabolismo , Cabeza Femoral/metabolismo , Articulación de la Cadera/citología , Humanos , Masculino , Persona de Mediana Edad , Osteoclastos/fisiología , Pronóstico , Fosfatasa Ácida Tartratorresistente/sangre
16.
Injury ; 51 Suppl 1: S12-S18, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32115206

RESUMEN

BACKGROUND: The risk of femoral neck fracture progressively increases with age. However, the reasons behind this consistent increase in the fracture risk can't be completely justified by the decrease in the bone mineral density. The objective of this study was to analyze the correlation between various bone structural features and age. STUDY DESIGN & METHODS: A total of 29 consecutive patients who suffered an intracapsular hip fracture and underwent joint replacement surgery between May 2012 and March 2013 were included in this study. A 2 cm × 1 cm Ø cylindrical trabecular bone sample was collected from the femoral heads and preserved in formaldehyde. Bone mineral density (BMD), microarchitecture, organic content and crystallography were analyzed using a Dual-energy X-ray absorptiometry scan, micro-CT scan, and high resolution magic-angle-spinning-nuclear magnetic resonance (MAS-NMR), respectively. Statistical correlations were made using Spearman´s or Pearson´s correlation tests depending on the distribution of the continuous variables. RESULTS: The mean patient age was 79.83 ± 9.31 years. A moderate negative correlation was observed between age and the hydrogen content in bone (1H), which is an indirect estimate to quantify the organic matrix (r = -0.512, p = 0.005). No correlations were observed between BMD, trabecular number, trabecular thickness, phosphorous content, apatite crystal size, and age (r = 0.06, p = 0.755; r = -0.008, p = 0.967; r = -0.046, p = 0.812; r = -0.152, p = 0.430, respectively). A weak positive correlation was observed between Charlson´s comorbidity index (CCI) and c-axis of the hydroxiapatite (HA) crystals (r = -0.400, p = 0.035). CONCLUSION: The femoral head relative protein content progressively decreases with age. BMD was not correlated with other structural bone parameters and age. Patients with higher comorbidity scores had larger HA crystals. The present results suggest that the progressive increase in the hip fracture risk in elderly patients could be partially explained by the lower bone protein content in this age group.


Asunto(s)
Envejecimiento/fisiología , Densidad Ósea/fisiología , Fracturas del Cuello Femoral/diagnóstico por imagen , Cabeza Femoral/patología , Fracturas Osteoporóticas/diagnóstico por imagen , Absorciometría de Fotón , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Fracturas del Cuello Femoral/fisiopatología , Humanos , Masculino , Fracturas Osteoporóticas/fisiopatología , Microtomografía por Rayos X
17.
Arch Osteoporos ; 15(1): 8, 2020 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-31897775

RESUMEN

A case-control study assessing the association of DXA-derived 3D measurements at lumbar spine with osteoporotic hip fractures was performed. Stronger association was found between transcervical hip fractures and integral (AUC = 0.726), and cortical (AUC = 0.696) measurements at the lumbar spine compared with measurements at the trabecular bone (AUC = 0.617); although femur areal bone mineral density (aBMD) remains the referent measurement for hip fracture risk evaluation (AUC = 0.838). PURPOSE: The aim of the present study was to evaluate the association between DXA-derived 3D measurements at lumbar spine and osteoporotic hip fractures. METHODS: We analyzed a case-control database composed by 61 women with transcervical hip fractures and 61 age-matched women without any type of fracture. DXA scans at lumbar spine were acquired, and areal bone mineral density (aBMD) was measured. Integral, trabecular and cortical volumetric BMD (vBMD), cortical thickness, and cortical surface BMD (sBMD) at different regions of interest were assessed using a DXA-based 3D modeling software. Descriptive statistics, tests of difference, odds ratio (OR), and area under the receiver operating curve (AUC) were used to compare hip fracture and control groups. RESULTS: Integral vBMD, cortical vBMD, cortical sBMD, and cortical thickness were the DXA-derived 3D measurements at lumbar spine that showed the stronger association with transcervical hip fractures, with AUCs in the range of 0.685-0.726, against 0.670 for aBMD. The highest AUC (0.726) and OR (2.610) at the lumbar spine were found for integral vBMD at the posterior vertebral elements. Significantly, lower AUC (0.617) and OR (1.607) were found for trabecular vBMD at the vertebral body. Overall, total femur aBMD remains the DXA-derived measurement showing the highest AUC (0.838) and OR (6.240). CONCLUSION: This study showed the association of DXA-derived measurements at lumbar spine with transcervical hip fractures. A strong association between vBMD at the posterior vertebral elements and transcervical hip fractures was observed, probably because of global deterioration of the cortical bone. Further studies should be carried out to investigate on the relative risk of transcervical fracture in patients with long-term cortical structural deterioration.


Asunto(s)
Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas de Cadera/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Fracturas Osteoporóticas/diagnóstico por imagen , Absorciometría de Fotón/métodos , Anciano , Densidad Ósea/fisiología , Estudios de Casos y Controles , Hueso Cortical/diagnóstico por imagen , Femenino , Fracturas del Cuello Femoral/fisiopatología , Fracturas de Cadera/fisiopatología , Humanos , Imagenología Tridimensional , Persona de Mediana Edad , Fracturas Osteoporóticas/complicaciones , Fracturas Osteoporóticas/fisiopatología
18.
Biomed Pharmacother ; 123: 109801, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31901717

RESUMEN

The aim of this study was to investigate the effect of Gotfried positive reduction (GPR) on repair of femoral neck fracture in rabbits and its underlying mechanisms. Male New Zealand white rabbits were employed to establish the model of femoral neck fracture. All the rabbits were randomly divided into four groups: control, open accurate reduction (OR), closed Gotfried negative support reduction (CR-N) and closed Gotfried positive support reduction (CR-P). At the 8th and 12th week after surgery, the anteroposterior and lateral radiographs of their hip joints were taken by X-ray, and local hemodynamics of their hip joints was detected by ultrasound. Histological examination was evaluated by HE staining and bone biological strength test was measured by testing machine, which was performed to study the repair of femoral neck fracture. Osteogenesis and angiogenesis-related proteins were measured by western blot in bone tissues and synovial tissues. The results revealed that the fracture healing intensity and blood supply in CR-P were better than those in CR-N and much more excellent than those in OR. In addition, the content of bone morphogenetic protein2 (BMP2), platelet derived growth factor (PDGF) and ocsteocalcin was higher in CR-P group than in CR-N, while lower in CR-P than OR. Furthermore, the expression of BMP2, COL-2 and angiopoietin (ANGPT) was upregulated in CR-P compared to CR-N and OR. Taken together, our results indicated that GPR was able to promote the repair of femoral neck fracture via enhancing osteogenesis and angiogenesis, which is valuable to us and shows good application prospect in bone tissue repair.


Asunto(s)
Fracturas del Cuello Femoral/fisiopatología , Fracturas del Cuello Femoral/cirugía , Curación de Fractura , Neovascularización Fisiológica , Osteogénesis , Angiopoyetinas/metabolismo , Animales , Fenómenos Biomecánicos , Líquidos Corporales/metabolismo , Proteínas Morfogenéticas Óseas/metabolismo , Colágeno Tipo II/metabolismo , Fracturas del Cuello Femoral/sangre , Fracturas del Cuello Femoral/diagnóstico por imagen , Hemodinámica , Osteocalcina/sangre , Factor de Crecimiento Derivado de Plaquetas/metabolismo , Conejos
19.
Can J Physiol Pharmacol ; 98(2): 61-66, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31491342

RESUMEN

Our study aimed to examine the status of plasma fatty acids (FAs), inflammatory markers, and lipid peroxidation in patients with femoral neck fractures. The study included 20 patients (64-86 years) with femoral neck fractures indicated for surgery and a control group of 17 elderly subjects without fractures or serious chronic diseases. Plasma was obtained during the first 12 h postfracture and presurgery and 7 days postop. Compared to the control, patients had significantly higher saturated FA (SFA) and monounsaturated FA as well as increased TNF-α and IL-6. Opposite to that, levels of individual and total n-6 polyunsaturated FA (PUFA), individual and total n-3 PUFA, n-6/n-3 ratio, and levels of thiobarbituric acid reactive substances (TBARS) were markedly lower in the patient than in the controls. On the seventh day after the surgery, we showed a further rise in the SFA, oleic acid, and TNF-α and reductions of n-6 PUFA and IL-6. Taken together, our results suggest that altered FA status, especially reduced PUFA, may influence hip fracture repair and even contribute to femoral fracture susceptibility in the elderly. A potential benefit from nutritional intervention with PUFA in prevention and (or) fracture healing should be considered.


Asunto(s)
Ácidos Grasos/sangre , Ácidos Grasos/química , Fracturas del Cuello Femoral/sangre , Anciano , Anciano de 80 o más Años , Femenino , Fracturas del Cuello Femoral/fisiopatología , Humanos , Interleucina-6/sangre , Masculino , Persona de Mediana Edad , Sustancias Reactivas al Ácido Tiobarbitúrico/metabolismo , Factor de Necrosis Tumoral alfa/sangre , Cicatrización de Heridas
20.
Hip Int ; 30(6): 810-817, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31450987

RESUMEN

INTRODUCTION: Femoral neck fractures are a major problem in orthopaedic practice, having a huge impact on society, and involving a large number of elderly patients for whom early recovery is paramount. Thus, the aim of this study was to compare 2 surgical approaches, direct anterior (DA group) versus posterolateral (PL group), used for bipolar hip hemiarthroplasty (BHA) with femoral neck fractures in order to assess pain recovery after surgery. Our hypothesis was that early pain recovery would be faster in the DA group. METHODS: 100 patients were randomised to surgery using either a DA group or PL group approach, and were then followed up for 6 months. Surgical time, intra- and postoperative complications were recorded for each patient. The main outcome, pain, was recorded using an NRS scale at 3 days, 1, 3 and 6 months after surgery. At the same time, patient status was evaluated using Activities of Daily Living and Cumulated Ambulation Score scales. RESULTS: Surgical time was longer in the DA group (p < 0.0001). Pain perception at 3 days and at 1 month after surgery was significantly lower in DA group patients (p < 0.0001). The results of the other scales were comparable in the 2 groups (at 3 days, 1 and 3 months after surgery). DISCUSSION: The DA approach offers a significant advantage in terms of pain perception up to 1 month after the operation. Early recovery in terms of pain perception is an important finding. Future studies should explore whether this early pain reduction could translate into a faster rehabilitation programme for an earlier recovery of full function.Clinical trial registration: Protocol 423/CE; Study n. CE 41/15.


Asunto(s)
Actividades Cotidianas , Fracturas del Cuello Femoral/cirugía , Hemiartroplastia/métodos , Articulación de la Cadera/cirugía , Rango del Movimiento Articular/fisiología , Anciano , Anciano de 80 o más Años , Femenino , Fracturas del Cuello Femoral/fisiopatología , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Tempo Operativo , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA