RESUMEN
A specific, fast and sensitive LC-MS/MS assay was developed for the determination of finasteride in human plasma using betamethsone dipropionate as the internal standard (IS). The limit of quantification was 1.0 ng/ml and the method was linear in the range of 1.0-25.0 ng/ml. The retention times were 0.75 min for finasteride and 0.85 min for IS. Method intra-batch precision and accuracy ranged from 3.6 to 7.1%, and 96.6 to 103.9%, respectively. Inter-batch precision ranged from 2.5 to 3.4%, while Inter-batch accuracy ranged from 100.3 to 103.5%. The analytical method was applied to evaluate the pharmacokinetic and relative bioavailability of 2 different pharmaceutical formulations containing 1.0 mg of finasteride. This study evaluated 38 volunteers in a randomized, 2-period crossover study with 7 days washout period between doses. The geometric mean and respective 90% CI of finasteride test/reference percent ratios were 95.68% (91.2 - 104.6%) for Cmax, 97.5% (92.1-103.3%) for AUC0-t and 98.1 (92.67-103.8) for AUC0-inf. Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for Cmax and AUC0-inf, it was concluded that the test formulation is bioequivalent to the reference one with respect to the rate and extent of absorption of finasteride.
Asunto(s)
Finasterida/sangre , Finasterida/farmacocinética , Inhibidores de 5-alfa-Reductasa/sangre , Inhibidores de 5-alfa-Reductasa/farmacocinética , Adolescente , Adulto , Betametasona/análogos & derivados , Betametasona/sangre , Betametasona/farmacocinética , Disponibilidad Biológica , Cromatografía Líquida de Alta Presión , Estudios Cruzados , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Equivalencia Terapéutica , Adulto JovenRESUMEN
Two different finasteride (CAS 98319-26-7) tablet formulations were evaluated for their relative bioavailability (Flaxin tablets 5 mg, as the test formulation vs reference formulation, tablets 5 mg) in 23 healthy male volunteers who received a single 5 mg oral dose of each preparation. The study was open, randomized with a two-period crossover design and a 7-day washout period. Plasma samples were obtained over a 48-h interval. The finasteride concentrations were determined by high-pressure liquid chromatography (HPLC) coupled to tandem mass spectrometry (LC-MS-MS). The analytical method developed has a limit of quantitation (LOQ) of 0.50 ng/ml in plasma. For the quality control the measured concentration was 2.05 +/- 0.14 ng/ml (mean +/- SD, n = 30) with a precision of 6.9% and an accuracy of 2.55% at a concentration of the starting solution of 2.00 ng/ml, while with 20.00 ng/ml starting solution the measured concentrations were 20 +/- 0.80 ng/ml (n = 30) with a precision of 3.81% and an accuracy of 0.09%. From the plasma finasteride concentration vs time curves the following pharmacokinetics parameters were obtained: AUC0-48, AUC0-infinity, Cmax, Cmax/AUC0-48, Ke, elimination half-life and tmax. Geometric mean test/reference formulations individual percent ratio was 95.71 for AUC0-48 h and 88.70% for Cmax. The 90% confidence interval for the geometric mean of the individual ratio test/reference formulations was 95.70-120.20% for AUC0-48 h, 94.60-121.30 for AUC0-infinity and 88.70-108% for Cmax. Since for both Cmax or AUC the 90% Cl values are within the interval proposed by the Food and Drug Administration, the test formulation is bioequivalent to the reference formulation for both the rate and extent of absorption after single dose administration.