Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.067
Filtrar
1.
Oper Neurosurg (Hagerstown) ; 27(4): 431-439, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39283098

RESUMEN

BACKGROUND AND OBJECTIVES: Frameless deep brain stimulation (DBS) offers advantages in terms of patient comfort and reduced operative time. However, the need for bony fiducial markers for localization remains a drawback due to the time-consuming and uncomfortable procedure. An alternative localization method involves the direct tracking of an intraoperative 3-dimensional scanner. This study aims to assess the accuracy of the NexFrame frameless DBS system in conjunction with the O-Arm (Medtronic Inc.), both with and without fiducial markers. METHODS: The locations of 100 DBS leads were determined, with 50 cases using fiducial-free localization and 50 involving fiducial markers. The coordinates were compared with the expected intraoperative targets. Absolute errors in the X, Y, and Z coordinates (ΔX, ΔY, and ΔZ) were calculated, along with the vector error (Euclidean) (vector error ). RESULTS: The vector error averaged 1.61 ± 0.49 mm (right) and 1.52 ± 0.60 mm (left) for the group without fiducial bone markers and 1.66 ± 0.69 (right) and 1.44 ± 0.65 mm (left) for the other cohort (P = .76 right; P = .67 left). Absolute errors in the X, Y, and Z coordinates for the fiducial-free group were 0.88 ± 0.55, 0.79 ± 0.45, and 0.79 ± 0.57 mm (right) and 0.72 ± 0.37, 0.78 ± 0.56, and 0.77 ± 0.71 mm (left). For the group with fiducial markers, these errors were 0.87 ± 0.72, 0.92 ± 0.39, and 0.86 ± 0.50 mm (right) and 0.75 ± 0.33, 0.80 ± 0.51, and 0.73 ± 0.64 mm (left) with no statistically significant difference. CONCLUSION: Our analysis of the accuracy of NexFrame DBS, both with and without fiducial markers, using an intraoperative navigable cone-beam computed tomography, demonstrates that both techniques provide sufficient and equivalent 3-dimensional accuracy.


Asunto(s)
Estimulación Encefálica Profunda , Marcadores Fiduciales , Neuronavegación , Humanos , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Masculino , Femenino , Neuronavegación/métodos , Neuronavegación/instrumentación , Persona de Mediana Edad , Anciano , Imagenología Tridimensional/métodos , Adulto , Electrodos Implantados
2.
Nat Nanotechnol ; 19(9): 1333-1343, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38956320

RESUMEN

Neuromodulation technologies are crucial for investigating neuronal connectivity and brain function. Magnetic neuromodulation offers wireless and remote deep brain stimulations that are lacking in optogenetic- and wired-electrode-based tools. However, due to the limited understanding of working principles and poorly designed magnetic operating systems, earlier magnetic approaches have yet to be utilized. Furthermore, despite its importance in neuroscience research, cell-type-specific magnetic neuromodulation has remained elusive. Here we present a nanomaterials-based magnetogenetic toolbox, in conjunction with Cre-loxP technology, to selectively activate genetically encoded Piezo1 ion channels in targeted neuronal populations via torque generated by the nanomagnetic actuators in vitro and in vivo. We demonstrate this cell-type-targeting magnetic approach for remote and spatiotemporal precise control of deep brain neural activity in multiple behavioural models, such as bidirectional feeding control, long-term neuromodulation for weight control in obese mice and wireless modulation of social behaviours in multiple mice in the same physical space. Our study demonstrates the potential of cell-type-specific magnetogenetics as an effective and reliable research tool for life sciences, especially in wireless, long-term and freely behaving animals.


Asunto(s)
Encéfalo , Animales , Ratones , Encéfalo/metabolismo , Encéfalo/fisiología , Neuronas/metabolismo , Canales Iónicos/metabolismo , Canales Iónicos/genética , Optogenética/métodos , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Masculino , Ratones Endogámicos C57BL
3.
IEEE Pulse ; 15(2): 21-23, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39024064

RESUMEN

While The Big medical device makers may have a deep-pockets advantage in the neurostimulation space, many smaller players are innovating their way to advances that offer tantalizing hope for changing patients' lives.


Asunto(s)
Terapia por Estimulación Eléctrica , Humanos , Terapia por Estimulación Eléctrica/instrumentación , Neuroestimuladores Implantables , Ingeniería Biomédica , Estimulación Encefálica Profunda/instrumentación
4.
Biomed Phys Eng Express ; 10(5)2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38959873

RESUMEN

Objective. Recent innovative neurostimulators allow recording local field potentials (LFPs) while performing motor tasks monitored by wearable sensors. Inertial sensors can provide quantitative measures of motor impairment in people with subthalamic nucleus deep brain stimulation. To the best of our knowledge, there is no validated method to synchronize inertial sensors and neurostimulators without an additional device. This study aims to define a new synchronization method to analyze disease-related brain activity patterns during specific motor tasks and evaluate how LFPs are affected by stimulation and medication.Approach. Fourteen male subjects treated with subthalamic nucleus deep brain stimulation were recruited to perform motor tasks in four different medication and stimulation conditions. In each condition, a synchronization protocol was performed consisting of taps on the implanted neurostimulator, which produces artifacts in the LFPs that a nearby inertial sensor can simultaneously record.Main results. In 64% of the recruited subjects, induced artifacts were detected at least in one condition. Among those subjects, 83% of the recordings could be synchronized offline analyzing LFPs and wearables data. The remaining recordings were synchronized by video analysis.Significance. The proposed synchronization method does not require an external system (e.g., TENS electrodes) and can be easily integrated into clinical practice. The procedure is simple and can be carried out in a short time. A proper and simple synchronization will also be useful to analyze subthalamic neural activity in the presence of specific events (e.g., freezing of gait events) to identify predictive biomarkers.


Asunto(s)
Estimulación Encefálica Profunda , Núcleo Subtalámico , Humanos , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Masculino , Persona de Mediana Edad , Artefactos , Procesamiento de Señales Asistido por Computador , Adulto , Dispositivos Electrónicos Vestibles , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/fisiopatología , Encéfalo , Anciano
5.
Sensors (Basel) ; 24(13)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-39001075

RESUMEN

INTRODUCTION: The current approach to assessing bradykinesia in Parkinson's Disease relies on the Unified Parkinson's Disease Rating Scale (UPDRS), which is a numeric scale. Inertial sensors offer the ability to probe subcomponents of bradykinesia: motor speed, amplitude, and rhythm. Thus, we sought to investigate the differential effects of high-frequency compared to low-frequency subthalamic nucleus (STN) deep brain stimulation (DBS) on these quantified facets of bradykinesia. METHODS: We recruited advanced Parkinson's Disease subjects with a chronic bilateral subthalamic nucleus (STN) DBS implantation to a single-blind stimulation trial where each combination of medication state (OFF/ON), electrode contacts, and stimulation frequency (60 Hz/180 Hz) was assessed. The Kinesia One sensor system was used to measure upper limb bradykinesia. For each stimulation trial, subjects performed extremity motor tasks. Sensor data were recorded continuously. We identified STN DBS parameters that were associated with improved upper extremity bradykinesia symptoms using a mixed linear regression model. RESULTS: We recruited 22 subjects (6 females) for this study. The 180 Hz STN DBS (compared to the 60 Hz STN DBS) and dopaminergic medications improved all subcomponents of upper extremity bradykinesia (motor speed, amplitude, and rhythm). For the motor rhythm subcomponent of bradykinesia, ventral contacts yielded improved symptom improvement compared to dorsal contacts. CONCLUSION: The differential impact of high- and low-frequency STN DBS on the symptoms of bradykinesia may advise programming for these patients but warrants further investigation. Wearable sensors represent a valuable addition to the armamentarium that furthers our ability to conduct objective, quantitative clinical assessments.


Asunto(s)
Estimulación Encefálica Profunda , Hipocinesia , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/fisiopatología , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Hipocinesia/terapia , Hipocinesia/fisiopatología , Núcleo Subtalámico/fisiopatología , Femenino , Masculino , Persona de Mediana Edad , Anciano
6.
J Neural Eng ; 21(4)2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39029490

RESUMEN

Objective.Understanding the generative mechanism between local field potentials (LFP) and neuronal spiking activity is a crucial step for understanding information processing in the brain. Up to now, most approaches have relied on simply quantifying the coupling between LFP and spikes. However, very few have managed to predict the exact timing of spike occurrence based on LFP variations.Approach.Here, we fill this gap by proposing novel spiking Laguerre-Volterra network (sLVN) models to describe the dynamic LFP-spike relationship. Compared to conventional artificial neural networks, the sLVNs are interpretable models that provide explainable features of the underlying dynamics.Main results.The proposed networks were applied on extracellular microelectrode recordings of Parkinson's Disease patients during deep brain stimulation (DBS) surgery. Based on the predictability of the LFP-spike pairs, we detected three neuronal populations with unique signal characteristics and sLVN model features.Significance.These clusters were indirectly associated with motor score improvement following DBS surgery, warranting further investigation into the potential of spiking activity predictability as an intraoperative biomarker for optimal DBS lead placement.


Asunto(s)
Potenciales de Acción , Estimulación Encefálica Profunda , Redes Neurales de la Computación , Neuronas , Humanos , Potenciales de Acción/fisiología , Neuronas/fisiología , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Masculino , Femenino , Enfermedad de Parkinson/fisiopatología , Enfermedad de Parkinson/terapia , Persona de Mediana Edad , Modelos Neurológicos , Anciano , Microelectrodos
7.
Artículo en Inglés | MEDLINE | ID: mdl-38949928

RESUMEN

Brain-computer interfaces (BCIs) provide a communication interface between the brain and external devices and have the potential to restore communication and control in patients with neurological injury or disease. For the invasive BCIs, most studies recruited participants from hospitals requiring invasive device implantation. Three widely used clinical invasive devices that have the potential for BCIs applications include surface electrodes used in electrocorticography (ECoG) and depth electrodes used in Stereo-electroencephalography (SEEG) and deep brain stimulation (DBS). This review focused on BCIs research using surface (ECoG) and depth electrodes (including SEEG, and DBS electrodes) for movement decoding on human subjects. Unlike previous reviews, the findings presented here are from the perspective of the decoding target or task. In detail, five tasks will be considered, consisting of the kinematic decoding, kinetic decoding,identification of body parts, dexterous hand decoding, and motion intention decoding. The typical studies are surveyed and analyzed. The reviewed literature demonstrated a distributed motor-related network that spanned multiple brain regions. Comparison between surface and depth studies demonstrated that richer information can be obtained using surface electrodes. With regard to the decoding algorithms, deep learning exhibited superior performance using raw signals than traditional machine learning algorithms. Despite the promising achievement made by the open-loop BCIs, closed-loop BCIs with sensory feedback are still in their early stage, and the chronic implantation of both ECoG surface and depth electrodes has not been thoroughly evaluated.


Asunto(s)
Interfaces Cerebro-Computador , Electrocorticografía , Electrodos Implantados , Movimiento , Humanos , Electrocorticografía/instrumentación , Electrocorticografía/métodos , Movimiento/fisiología , Estimulación Encefálica Profunda/instrumentación , Fenómenos Biomecánicos , Electroencefalografía/métodos , Electroencefalografía/instrumentación , Electrodos , Corteza Motora/fisiología , Mano/fisiología , Algoritmos
8.
Clin Neurophysiol ; 165: 1-15, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38941959

RESUMEN

OBJECTIVE: Parkinsonian motor symptoms are linked to pathologically increased beta oscillations in the basal ganglia. Studies with externalised deep brain stimulation electrodes showed that Parkinson patients were able to rapidly gain control over these pathological basal ganglia signals through neurofeedback. Studies with fully implanted deep brain stimulation systems duplicating these promising results are required to grant transferability to daily application. METHODS: In this study, seven patients with idiopathic Parkinson's disease and one with familial Parkinson's disease were included. In a postoperative setting, beta oscillations from the subthalamic nucleus were recorded with a fully implanted deep brain stimulation system and converted to a real-time visual feedback signal. Participants were instructed to perform bidirectional neurofeedback tasks with the aim to modulate these oscillations. RESULTS: While receiving regular medication and deep brain stimulation, participants were able to significantly improve their neurofeedback ability and achieved a significant decrease of subthalamic beta power (median reduction of 31% in the final neurofeedback block). CONCLUSION: We could demonstrate that a fully implanted deep brain stimulation system can provide visual neurofeedback enabling patients with Parkinson's disease to rapidly control pathological subthalamic beta oscillations. SIGNIFICANCE: Fully-implanted DBS electrode-guided neurofeedback is feasible and can now be explored over extended timespans.


Asunto(s)
Ritmo beta , Estimulación Encefálica Profunda , Neurorretroalimentación , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/fisiopatología , Neurorretroalimentación/métodos , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Ritmo beta/fisiología , Anciano , Núcleo Subtalámico/fisiopatología , Núcleo Subtalámico/fisiología , Electrodos Implantados
9.
Nat Commun ; 15(1): 4601, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38834558

RESUMEN

Precise neurostimulation can revolutionize therapies for neurological disorders. Electrode-based stimulation devices face challenges in achieving precise and consistent targeting due to the immune response and the limited penetration of electrical fields. Ultrasound can aid in energy propagation, but transcranial ultrasound stimulation in the deep brain has limited spatial resolution caused by bone and tissue scattering. Here, we report an implantable piezoelectric ultrasound stimulator (ImPULS) that generates an ultrasonic focal pressure of 100 kPa to modulate the activity of neurons. ImPULS is a fully-encapsulated, flexible piezoelectric micromachined ultrasound transducer that incorporates a biocompatible piezoceramic, potassium sodium niobate [(K,Na)NbO3]. The absence of electrochemically active elements poses a new strategy for achieving long-term stability. We demonstrated that ImPULS can i) excite neurons in a mouse hippocampal slice ex vivo, ii) activate cells in the hippocampus of an anesthetized mouse to induce expression of activity-dependent gene c-Fos, and iii) stimulate dopaminergic neurons in the substantia nigra pars compacta to elicit time-locked modulation of nigrostriatal dopamine release. This work introduces a non-genetic ultrasound platform for spatially-localized neural stimulation and exploration of basic functions in the deep brain.


Asunto(s)
Estimulación Encefálica Profunda , Hipocampo , Ondas Ultrasónicas , Animales , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Ratones , Ratones Endogámicos C57BL , Neuronas Dopaminérgicas , Masculino , Dopamina/metabolismo , Proteínas Proto-Oncogénicas c-fos/metabolismo , Sustancia Negra , Neuronas/fisiología , Transductores
10.
Nat Commun ; 15(1): 4017, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38740759

RESUMEN

Ultrasound-driven bioelectronics could offer a wireless scheme with sustainable power supply; however, current ultrasound implantable systems present critical challenges in biocompatibility and harvesting performance related to lead/lead-free piezoelectric materials and devices. Here, we report a lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation, which integrates two developed lead-free sandwich porous 1-3-type piezoelectric composite elements with enhanced harvesting performance in a flexible printed circuit board. The implant is ultrasonically powered through a portable external dual-frequency transducer and generates programmable biphasic stimulus pulses in clinically relevant frequencies. Furthermore, we demonstrate ultrasound-driven implants for long-term biosafety therapy in deep brain stimulation through an epileptic rodent model. With biocompatibility and improved electrical performance, the lead-free materials and devices presented here could provide a promising platform for developing implantable ultrasonic electronics in the future.


Asunto(s)
Estimulación Encefálica Profunda , Tecnología Inalámbrica , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Animales , Tecnología Inalámbrica/instrumentación , Ratas , Electrodos Implantados , Epilepsia/terapia , Masculino , Prótesis e Implantes , Ratas Sprague-Dawley , Transductores , Diseño de Equipo , Ondas Ultrasónicas
11.
J Neurosci Methods ; 407: 110156, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38703796

RESUMEN

BACKGROUND: DBS entails the insertion of an electrode into the patient brain, enabling Subthalamic nucleus (STN) stimulation. Accurate delineation of STN borders is a critical but time-consuming task, traditionally reliant on the neurosurgeon experience in deciphering the intricacies of microelectrode recording (MER). While clinical outcomes of MER have been satisfactory, they involve certain risks to patient safety. Recently, there has been a growing interest in exploring the potential of local field potentials (LFP) due to their correlation with the STN motor territory. METHOD: A novel STN detection system, integrating LFP and wavelet packet transform (WPT) with stacking ensemble learning, is developed. Initial steps involve the inclusion of soft thresholding to increase robustness to LFP variability. Subsequently, non-linear WPT features are extracted. Finally, a unique ensemble model, comprising a dual-layer structure, is developed for STN localization. We harnessed the capabilities of support vector machine, Decision tree and k-Nearest Neighbor in conjunction with long short-term memory (LSTM) network. LSTM is pivotal for assigning adequate weights to every base model. RESULTS: Results reveal that the proposed model achieved a remarkable accuracy and F1-score of 89.49% and 91.63%. COMPARISON WITH EXISTING METHODS: Ensemble model demonstrated superior performance when compared to standalone base models and existing meta techniques. CONCLUSION: This framework is envisioned to enhance the efficiency of DBS surgery and reduce the reliance on clinician experience for precise STN detection. This achievement is strategically significant to serve as an invaluable tool for refining the electrode trajectory, potentially replacing the current methodology based on MER.


Asunto(s)
Estimulación Encefálica Profunda , Núcleo Subtalámico , Análisis de Ondículas , Núcleo Subtalámico/fisiología , Humanos , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Máquina de Vectores de Soporte , Aprendizaje Automático , Procesamiento de Señales Asistido por Computador , Microelectrodos
12.
Brain Stimul ; 17(3): 636-647, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38734066

RESUMEN

BACKGROUND: Transcranial ultrasound stimulation (TUS) is a non-invasive brain stimulation technique; when skull aberrations are compensated for, this technique allows, with millimetric accuracy, circumvention of the invasive surgical procedure associated with deep brain stimulation (DBS) and the limited spatial specificity of transcranial magnetic stimulation. OBJECTIVE: /hypothesis: We hypothesize that MR-guided low-power TUS can induce a sustained decrease of tremor power in patients suffering from medically refractive essential tremor. METHODS: The dominant hand only was targeted, and two anatomical sites were sonicated in this exploratory study: the ventral intermediate nucleus of the thalamus (VIM) and the dentato-rubro-thalamic tract (DRT). Patients (N = 9) were equipped with MR-compatible accelerometers attached to their hands to monitor their tremor in real-time during TUS. RESULTS: VIM neurostimulations followed by a low-duty cycle (5 %) DRT stimulation induced a substantial decrease in the tremor power in four patients, with a minimum of 89.9 % reduction when compared with the baseline power a few minutes after the DRT stimulation. The only patient stimulated in the VIM only and with a low duty cycle (5 %) also experienced a sustained reduction of the tremor (up to 93.4 %). Four patients (N = 4) did not respond. The temperature at target was 37.2 ± 1.4 °C compared to 36.8 ± 1.4 °C for a 3 cm away control point. CONCLUSIONS: MR-guided low power TUS can induce a substantial and sustained decrease of tremor power. Follow-up studies need to be conducted to reproduce the effect and better to understand the variability of the response amongst patients. MR thermometry during neurostimulations showed no significant thermal rise, supporting a mechanical effect.


Asunto(s)
Temblor Esencial , Humanos , Temblor Esencial/terapia , Temblor Esencial/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Núcleos Talámicos Ventrales/fisiología , Resultado del Tratamiento , Imagen por Resonancia Magnética , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación
13.
ACS Sens ; 9(6): 2877-2887, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38779969

RESUMEN

Precise assessment of wakefulness states during sevoflurane anesthesia and timely arousal are of paramount importance to refine the control of anesthesia. To tackle this issue, a bidirectional implantable microelectrode array (MEA) is designed with the capability to detect electrophysiological signal and perform in situ deep brain stimulation (DBS) within the dorsomedial hypothalamus (DMH) of mice. The MEA, modified with platinum nanoparticles/IrOx nanocomposites, exhibits exceptional characteristics, featuring low impedance, minimal phase delay, substantial charge storage capacity, high double-layer capacitance, and longer in vivo lifetime, thereby enhancing the sensitivity of spike firing detection and electrical stimulation (ES) effectiveness. Using this MEA, sevoflurane-inhibited neurons and sevoflurane-excited neurons, together with changes in the oscillation characteristics of the local field potential within the DMH, are revealed as indicative markers of arousal states. During the arousal period, varying-frequency ESs are applied to the DMH, eliciting distinct arousal effects. Through in situ detection and stimulation, the disparity between these outcomes can be attributed to the influence of DBS on different neurons. These advancements may further our understanding of neural circuits and their potential applications in clinical contexts.


Asunto(s)
Estimulación Encefálica Profunda , Microelectrodos , Sevoflurano , Animales , Sevoflurano/farmacología , Ratones , Estimulación Encefálica Profunda/instrumentación , Neuronas/efectos de los fármacos , Neuronas/fisiología , Masculino , Anestésicos por Inhalación , Estimulación Eléctrica , Platino (Metal)/química , Ratones Endogámicos C57BL
15.
JAMA Netw Open ; 7(4): e248654, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38687486

RESUMEN

Importance: Establishing a formal definition for neurological device abandonment has the potential to reduce or to prevent the occurrence of this abandonment. Objective: To perform a systematic review of the literature and develop an expert consensus definition for neurological device abandonment. Evidence Review: After a Royal Society Summit on Neural Interfaces (September 13-14, 2023), a systematic English language review using PubMed was undertaken to investigate extant definitions of neurological device abandonment. Articles were reviewed for relevance to neurological device abandonment in the setting of deep brain, vagal nerve, and spinal cord stimulation. This review was followed by the convening of an expert consensus group of physicians, scientists, ethicists, and stakeholders. The group summarized findings, added subject matter experience, and applied relevant ethics concepts to propose a current operational definition of neurological device abandonment. Data collection, study, and consensus development were done between September 13, 2023, and February 1, 2024. Findings: The PubMed search revealed 734 total articles, and after review, 7 articles were found to address neurological device abandonment. The expert consensus group addressed findings as germane to neurological device abandonment and added personal experience and additional relevant peer-reviewed articles, addressed stakeholders' respective responsibilities, and operationally defined abandonment in the context of implantable neurotechnological devices. The group further addressed whether clinical trial failure or shelving of devices would constitute or be associated with abandonment as defined. Referential to these domains and dimensions, the group proposed a standardized definition for abandonment of active implantable neurotechnological devices. Conclusions and Relevance: This study's consensus statement suggests that the definition for neurological device abandonment should entail failure to provide fundamental aspects of patient consent; fulfill reasonable responsibility for medical, technical, or financial support prior to the end of the device's labeled lifetime; and address any or all immediate needs that may result in safety concerns or device ineffectiveness and that the definition of abandonment associated with the failure of a research trial should be contingent on specific circumstances.


Asunto(s)
Consenso , Humanos , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/ética
16.
Epilepsy Res ; 202: 107356, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38564925

RESUMEN

Implantable brain recording and stimulation devices apply to a broad spectrum of conditions, such as epilepsy, movement disorders and depression. For long-term monitoring and neuromodulation in epilepsy patients, future extracranial subscalp implants may offer a promising, less-invasive alternative to intracranial neurotechnologies. To inform the design and assess the safety profile of such next-generation devices, we estimated extracranial complication rates of deep brain stimulation (DBS), cranial peripheral nerve stimulation (PNS), responsive neurostimulation (RNS) and existing subscalp EEG devices (sqEEG), as proxy for future implants. Pubmed was searched systematically for DBS, PNS, RNS and sqEEG studies from 2000 to February 2024 (48 publications, 7329 patients). We identified seven categories of extracranial adverse events: infection, non-infectious cutaneous complications, lead migration, lead fracture, hardware malfunction, pain and hemato-seroma. We used cohort sizes, demographics and industry funding as metrics to assess risks of bias. An inverse variance heterogeneity model was used for pooled and subgroup meta-analysis. The pooled incidence of extracranial complications reached 14.0%, with infections (4.6%, CI 95% [3.2 - 6.2]), surgical site pain (3.2%, [0.6 - 6.4]) and lead migration (2.6%, [1.0 - 4.4]) as leading causes. Subgroup analysis showed a particularly high incidence of persisting pain following PNS (12.0%, [6.8 - 17.9]) and sqEEG (23.9%, [12.7 - 37.2]) implantation. High rates of lead migration (12.4%, [6.4 - 19.3]) were also identified in the PNS subgroup. Complication analysis of DBS, PNS, RNS and sqEEG studies provides a significant opportunity to optimize the safety profile of future implantable subscalp devices for chronic EEG monitoring. Developing such promising technologies must address the risks of infection, surgical site pain, lead migration and skin erosion. A thin and robust design, coupled to a lead-anchoring system, shall enhance the durability and utility of next-generation subscalp implants for long-term EEG monitoring and neuromodulation.


Asunto(s)
Estimulación Encefálica Profunda , Humanos , Estimulación Encefálica Profunda/efectos adversos , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Electrodos Implantados/efectos adversos , Electroencefalografía/métodos , Electroencefalografía/instrumentación , Convulsiones/diagnóstico
17.
Science ; 384(6691): 42, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38574146

RESUMEN

Ingestible electronic pills can be used for targeted noninvasive neuromodulation.


Asunto(s)
Encéfalo , Estimulación Encefálica Profunda , Electrónica , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Estómago
18.
Neurotherapeutics ; 21(3): e00339, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38430811

RESUMEN

Prader-Willi syndrome (PWS) is a complex, genetic disorder characterized by multisystem involvement, including hyperphagia, maladaptive behaviors and endocrinological derangements. Recent developments in advanced neuroimaging have led to a growing understanding of PWS as a neural circuit disorder, as well as subsequent interests in the application of neuromodulatory therapies. Various non-invasive and invasive device-based neuromodulation methods, including vagus nerve stimulation (VNS), transcranial direct current stimulation (tDCS), repetitive transcranial magnetic stimulation (rTMS), and deep brain stimulation (DBS) have all been reported to be potentially promising treatments for addressing the major symptoms of PWS. In this systematic literature review, we summarize the recent literature that investigated these therapies, discuss the underlying circuits which may underpin symptom manifestations, and cover future directions of the field. Through our comprehensive search, there were a total of 47 patients who had undergone device-based neuromodulation therapy for PWS. Two articles described VNS, 4 tDCS, 1 rTMS and 2 DBS, targeting different symptoms of PWS, including aberrant behavior, hyperphagia and weight. Multi-center and multi-country efforts will be required to advance the field given the low prevalence of PWS. Finally, given the potentially vulnerable population, neuroethical considerations and dialogue should guide the field.


Asunto(s)
Estimulación Encefálica Profunda , Síndrome de Prader-Willi , Estimulación Transcraneal de Corriente Directa , Estimulación Magnética Transcraneal , Estimulación del Nervio Vago , Humanos , Síndrome de Prader-Willi/terapia , Estimulación del Nervio Vago/métodos , Estimulación del Nervio Vago/instrumentación , Estimulación Magnética Transcraneal/métodos , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Estimulación Transcraneal de Corriente Directa/métodos
20.
J Neurosurg ; 141(2): 406-411, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38489816

RESUMEN

OBJECTIVE: Conventional frame-based stereotactic systems have circumferential base frames, often necessitating deep brain stimulation (DBS) surgery in two stages: intracranial electrode insertion followed by surgical re-preparation and pulse generator implantation. Some patients do not tolerate awake surgery, underscoring the need for a safe alternative for asleep DBS surgery. A frame-based stereotactic system with a skull-mounted "key" in lieu of a circumferential base frame received US FDA clearance. The authors describe the system's application for single-stage, asleep DBS surgery in 8 patients at their institution and review its workflow and technical considerations. METHODS: Eight patients underwent DBS lead insertion and IPG implantation in a single surgical preparation under general anesthesia using the system. Postoperative CT imaging confirmed lead placement. RESULTS: Eight patients underwent implantation of 15 total leads targeting the ventral intermediate nucleus (4 patients), globus pallidus internus (GPi; 3 patients), and subthalamic nucleus (STN; 1 patient). Intraoperative microelectrode recording was conducted for GPi and STN targets. Postoperative CT imaging revealed a mean ± SD radial error of 1.24 ± 0.45 mm (n = 15 leads), without surgical complications. CONCLUSIONS: The stereotactic system facilitated safe and effective asleep, single-stage DBS surgery, maintaining traditional lead accuracy standards.


Asunto(s)
Anestesia General , Estimulación Encefálica Profunda , Electrodos Implantados , Técnicas Estereotáxicas , Humanos , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Núcleo Subtalámico/cirugía , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/cirugía , Globo Pálido/cirugía , Globo Pálido/diagnóstico por imagen , Adulto , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA