Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 8(1)2017 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-29278383

RESUMEN

We have studied the Fourier Transform Infrared (FT-IR) and the Fourier transform Raman (FT-Raman) spectra of stanozolol and oxandrolone, and we have performed quantum chemical calculations based on the density functional theory (DFT) with a B3LYP/6-31G (d, p) level of theory. The FT-IR and FT-Raman spectra were collected in a solid phase. The consistency between the calculated and experimental FT-IR and FT-Raman data indicates that the B3LYP/6-31G (d, p) can generate reliable geometry and related properties of the title compounds. Selected experimental bands were assigned and characterized on the basis of the scaled theoretical wavenumbers by their total energy distribution. The good agreement between the experimental and theoretical spectra allowed positive assignment of the observed vibrational absorption bands. Finally, the calculation results were applied to simulate the Raman and IR spectra of the title compounds, which show agreement with the observed spectra.


Asunto(s)
Anabolizantes/análisis , Oxandrolona/análisis , Teoría Cuántica , Estanozolol/análisis , Espectroscopía Infrarroja por Transformada de Fourier , Espectrometría Raman
2.
J Chromatogr A ; 985(1-2): 375-86, 2003 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-12580506

RESUMEN

The Medical Commission of the International Olympic Committee forbids the use of anabolic androgenic steroids and beta2-agonists to improve athletic performance. In this work we have selected examples of anabolic androgenic compounds and their metabolites to evaluate the GC-MS analysis of some trimethylsilyl derivatives. The aim is to set the best GC conditions to improve the detection within the whole range of analyte elution temperatures. The initial column temperature was changed to 105 or 140 degrees C followed by 40 degrees C min(-1) to 200 degrees C and then 15 degrees C min(-1) to 300 degrees C. Using 140 degrees C as the initial oven temperature it was possible to obtain narrower initial analyte distributions for the compounds that elutes at the beginning of the chromatogram as clenbuterol, mabuterol, epimethylenediol and norandrosterone, without loss of derivatized metabolites signal. Later. eluting analytes, such as the stanozolol metabolites, furazabol and oxandrolone were not affected. Temperatures below 140 degrees C. resulted in partial derivatization for some analytes mainly stanozolol related structures. Therefore evaluation of derivatization conditions as occurring in three steps, the vial, vaporization chamber and capillary column, was thoroughly assessed. The new program temperature improves the signal-to-noise ratio for some compounds and shows adequate resolution for endogenous compounds. Some of the difficult key separations necessary for doping control enforcement were also obtained with the proposed method.


Asunto(s)
Anabolizantes/análisis , Doping en los Deportes , Estanozolol/análisis , Detección de Abuso de Sustancias/normas , Cromatografía de Gases y Espectrometría de Masas/normas , Detección de Abuso de Sustancias/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA