Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Rev. bras. ativ. fís. saúde ; 27: 1-14, fev. 2022.
Artículo en Inglés | LILACS | ID: biblio-1382104

RESUMEN

Smartphone apps have been developed and investigated in validation studies for tracking human be-havior such as physical activity (PA) and sedentary behavior (SB). However, as it is unclear whether these apps are valid for tracking PA and SB when compared to research-grade accelerometers, thus, this systematic review aimed to investigate the validity of smartphone apps for tracking PA and SB using the accelerometer as a criterion measure. A systematic search was conducted in PubMed, Web of Science, SportDiscus, and Scopus databases. The mean percentage difference (MPD) was used to evaluate criterion validity. Ten studies (n = 662) validating different apps using ActiGraph accelerometers as criteria measure (six were conducted in free-living conditions, two in laboratory conditions, and two in both conditions) were included for analyses. While four apps were considered valid for tracking PA, six were not valid or fully valid. The MPD analysis revealed that apps provide no valid scores for tracking PA measures (MPD = -12.6 ­ 37.7). The scarcity of studies investigat-ing SB limits the tracking of the results on this behavior. Study designs, smartphone location, and exercise intensity tend to affect the accuracy of apps tracking PA; thus, the current review showed conflicting results among studies. This review shows that it is not possible to generalize the valid scores for all apps


Aplicativos para smartphones têm sido desenvolvidos e investigados em estudos de validação para rastrea-mento de comportamento humano, como atividade física (AF) e comportamento sedentário (CS). No entan-to, como não está claro se esses aplicativos são válidos para rastrear AF e CS quando comparados a acelerôme-tros de grau de pesquisa, portanto, essa revisão sistemática teve o objetivo investigar a validade de aplicativos de smartphone para rastreamento de AF e CS usando o acelerômetro como medida de critério. Uma busca sistemática foi realizada em quatro bases de dados. A diferença percentual média (MPD) foi utilizada para avaliar a validade de critério. Dez estudos (n = 662) validando diferentes aplicativos usando acelerômetros ActiGraph como medida de critério (seis foram realizados em condições de vida diária, dois em condições de laboratório e dois em ambas as condições) foram incluídos para análise. Enquanto quatro aplicativos foram considerados válidos para rastreamento de AF, seis não eram válidos ou totalmente válidos. A análise do MPD revelou que os aplicativos não fornecem pontuações válidas para rastrear medidas de AF (MPD = -12,6 ­ 37,7). A escassez de estudos investigando o CS limita o rastreamento dos resultados sobre esse comportamento. Desenhos de estudo, localização do smartphone e intensidade do exercício tendem a afetar a precisão dos aplicativos que rastreiam AF; assim, a presente revisão mostrou resultados conflitantes entre os estudos. Esta revisão mostra que não é possível generalizar as pontuações válidas para todos os aplicativos.


Asunto(s)
Epidemiología , Equipos de Medición de Riesgos , Acelerometría , Sedestación
2.
Braz. J. Pharm. Sci. (Online) ; 58: e19558, 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1394032

RESUMEN

Abstract Licania macrophylla is a medicinal plant from the Amazon. It is mainly used in the form of a decoction and has been reported to contain several phenolic compounds. However, the effect of seasonality on the phenolic composition and antioxidant potential of this plant has not been well studied, especially in the Amazon region, an area affected by the rainy and less-rainy seasons. Therefore, we evaluated the seasonality of these aromatic compounds and the antioxidant potential of the extracts from L. macrophylla stem bark. We also determined the correlation between the extraction methods used and precipitation levels during each period for 1 year. The total flavonoid and phenolic content, DPPH-scavenging potential, percentage of phosphomolybdenum complex reduction, and iron-reducing power were quantified. The levels of phenolic compounds were the highest in June, whereas those of flavonoids were the highest in September and October; however, these differences were not significant. The extracts from April, November, and June showed the best results for DPPH scavenging, phosphomolybdenum reduction, and iron reduction power, respectively. Significant differences in the phenolic content and DPPH-scavenging activity were observed between the more- and less-rainy seasons. The total phenolic content was positively correlated with FRAP and DPPH, whereas flavonoid levels were negatively correlated.


Asunto(s)
Plantas Medicinales/efectos adversos , Estaciones del Año , Extractos Vegetales/análisis , Chrysobalanaceae/clasificación , Compuestos Fenólicos , Antioxidantes/análisis , Equipos de Medición de Riesgos
3.
Estud. Psicol. (Campinas, Online) ; 38: e180157, 2021. tab, graf
Artículo en Inglés | Index Psicología - Revistas, LILACS | ID: biblio-1133860

RESUMEN

Tradeoff analysis, between generalizability, precision, and realism, guides methodological choices in organizational behavior. These methodological choices were systematically reviewed in Brazilian articles and books (1996-2017) to answer the following question: why are there no Brazilian studies on organizational behavior that use big data or analytics? Among 1062 research articles on organizational behavior, published in 19 psychology and business journals, 68% used scales, and only 10% used observation. Observation was often unstructured and supported other methods. The focus was on "saying," instead of "doing". Big data and analytics have the potential to simultaneously reach generalizability, precision, and realism and may pave the way for new conclusions. Additionally, these methods could transform research in organizational behavior.


A análise de custo-benefício entre generalidade, precisão e realismo guia escolhas metodológicas em comportamento organizacional. Estas foram sistematicamente revistas em artigos e livros (1996-2017) brasileiros com o objetivo de responder à pergunta: por que não há estudos em comportamento organizacional no Brasil que usem big data ou analytics? Dentre 1.062 artigos com relatos de pesquisa sobre comportamento organizacional publicados em 19 periódicos de Psicologia e Administração, 68% empregaram escalas e apenas 10% a observação. A observação foi muito frequentemente adotada de forma não estruturada e servindo de suporte a outros métodos. O foco foi no "falar" e não no "fazer". Big data e analytics têm o potencial para atingir ao mesmo tempo a generalidade, a precisão e o realismo e podem abrir o caminho para novas conclusões, sendo talvez capaz de transformar a investigação em comportamento organizacional.


Asunto(s)
Análisis Multivariante , Equipos de Medición de Riesgos , Técnicas de Observación Conductual
4.
Washington, D.C.; PAHO; 2020-12-15.
en Inglés | PAHO-IRIS | ID: phr-53145

RESUMEN

La hipertension es el principal factor de riesgo modificable de algunas enfermedades graves como las enfermedades cardiovasculares (accidentes cerebrovasculares y cardiopatías isquémicas), la preeclampsia y la eclampsia (una causa muy importante de muerte en las embarazadas, así como de retraso del crecimiento fetal y mortinatos) y la enfermedad renal crónica. A nivel mundial, más de mil millones de personas tienen hipertensión, y la prevalencia es mayor en los países de ingresos bajos y medianos. La medición exacta de la presión arterial es esencial para detectar y tratar adecuadamente a las personas con hipertensión, un trastorno que constituye un asesino silencioso que causa pocos síntomas. La falta de acceso a dispositivos de determinación de la presión arterial exactos y asequibles constituye un obstáculo importante para una atención médica adecuada, en particular en los entornos de recursos escasos. La medición manual está siendo reemplazada gradualmente por la medición automatizada debido a los problemas ambientales derivados del mercurio, la falta de calibración y las mediciones incorrectas de los dispositivos aneroides en la práctica clínica, así como por la exactitud uniforme superior que ofrecen los dispositivos automáticos validados. Sin embargo, con frecuencia existe cierta preocupación respecto a la exactitud de los dispositivos automatizados que no se han validado. Este documento actualiza la orientación de la OMS sobre dispositivos de medición de la presión arterial del 2005. También responde a la preocupación existente por la carencia de dispositivos exactos y de buena calidad, especialmente en los países de ingresos bajos y medianos mediante una consulta técnica y examen de expertos.


Asunto(s)
Hipertensión , Enfermedades Cardiovasculares , Cardiopatías , Traumatismos Cerebrovasculares , Preeclampsia , Eclampsia , Fallo Renal Crónico , Enfermedades Renales , Presión Arterial , Rectoría y Gobernanza del Sector de Salud , Equipos de Medición de Riesgos
5.
Artículo en Español | PAHO-IRIS | ID: phr-52467

RESUMEN

[RESUMEN]. La hipertensión arterial es una causa modificable muy prevalente de enfermedades cardiovasculares, accidentes cerebrovasculares y muerte. Medir con exactitud la presión arterial es fundamental, dado que un error de medición de 5 mmHg puede ser motivo para clasificar incorrectamente como hipertensas a 84 millones de personas en todo el mundo. En la presente declaración de posición se resumen los procedimientos para optimizar el desempeño del observador al medir la presión arterial en el consultorio, con atención especial a los entornos de ingresos bajos o medianos, donde esta medición se ve complicada por limitaciones de recursos y tiempo, sobrecarga de trabajo y falta de suministro eléctrico. Es posible reducir al mínimo muchos errores de medición con una preparación adecuada de los pacientes y el uso de técnicas estandarizadas. Para simplificar la medición y prevenir errores del observador, deben usarse tensiómetros semiautomáticos o automáticos de manguito validados, en lugar del método por auscultación. Pueden ayudar también la distribución de tareas, la creación de un área específica de medición y el uso de aparatos semiautomáticos o de carga solar. Es fundamental garantizar la capacitación inicial y periódica de los integrantes del equipo de salud. Debe considerarse la implementación de programas de certificación de bajo costo y fácilmente accesibles con el objetivo de mejorar la medición de la presión arterial.


[ABSTRACT]. High blood pressure (BP) is a highly prevalent modifiable cause of cardiovascular disease, stroke, and death. Accurate BP measurement is critical, given that a 5-mmHg measurement error may lead to incorrect hypertension status classification in 84 million individuals worldwide. This position statement summarizes procedures for optimizing observer performance in clinic BP measurement, with special attention given to low-to-middle-income settings, where resource limitations, heavy workloads, time constraints, and lack of electrical power make measurement more challenging. Many measurement errors can be minimized by appropriate patient preparation and standardized techniques. Validated semi-automated/automated upper arm cuff devices should be used instead of auscultation to simplify measurement and prevent observer error. Task sharing, creating a dedicated measurement workstation, and using semi-automated or solar-charged devices may help. Ensuring observer training, and periodic re-training, is critical. Low-cost, easily accessible certification programs should be considered to facilitate best BP measurement practice.


[RESUMO]. A hipertensão é uma causa altamente prevalente de doença cardiovascular, acidente vascular cerebral e morte. A medição precisa da pressão arterial (PA) é um aspecto crítico, uma vez que erros de mensuração da ordem de 5 mmHg podem levar a uma classificação incorreta do status de hipertensão em 84 milhões de pessoas em todo o mundo. O presente posicionamento resume os procedimentos para otimizar o desempenho do observador (o indivíduo responsável pela mensuração da PA) na mensuração clínica da PA, com atenção especial para contextos de baixa a média renda, onde recursos limitados, cargas de trabalho pesadas, restrições de tempo e falta de energia elétrica tornam mais desafiadora a tarefa de medir a PA. Muitos erros de mensuração podem ser minimizados pela preparação adequada do paciente e pelo uso de técnicas padronizadas. Para simplificar a mensuração e evitar erros do observador, devem-se utilizar dispositivos semiautomatizados ou automatizados validados, com manguito para braço, ao invés de auscultação. O compartilhamento de tarefas, a criação de uma estação de trabalho dedicada à mensuração e o uso de dispositivos semiautomatizados ou com carga solar podem ajudar. É essencial que seja assegurado o treinamento e retreinamento periódico do observador. Programas de certificação de baixo custo e de fácil acesso devem ser considerados para facilitar a adoção das melhores práticas na mensuração da PA.


Asunto(s)
Presión Arterial , Equipos de Medición de Riesgos , Consenso , Salud Global , Hipertensión , Oscilometría , Presión Arterial , Equipos de Medición de Riesgos , Consenso , Salud Global , Hipertensión , Oscilometría , Presión Arterial , Equipos de Medición de Riesgos , Salud Global , Hipertensión , Oscilometría
6.
Fisioter. Mov. (Online) ; 33: e003314, 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1090396

RESUMEN

Abstract Introduction: Spine problems are common, and assessment of spine flexibility provides relevant information; however, alternative evaluation methods need to be validated. Objective: To evaluate the concurrent validity of the Flexicurve using 3D videogrammetry as a reference value to assess spinal flexion and extension in the lumbar and thoracic regions. Method: The consecutive sample consisted of 39 individuals aged between 18 and 50 years. Two consecutive evaluations were performed by the same rater on the same day and at the same location: (1) Flexicurve and (2) 3D videogrammetry. The assessments were performed with the spine in the neutral position, followed by maximum flexion and extension. The range of motion (ROM) in the maximum flexion and extension positions was calculated in MATLAB® and defined as the difference between the maximum flexion or extension angle and that of the neutral position. Statistical analyses used were the Pearson Product-Moment Correlation coefficient, RMS error and Bland-Altman plot (α < 0.05). Results: The ROM between instruments was similar, with high correlations for thoracic flexion (r = 0.751), extension (r = 0.814) and lumbar flexion (r = 0.853), and RMS errors under 8°. The correlation for lumbar extension was moderate (r = 0.613) and the RMS error was more than 10°. The limits of agreement varied between ± 10º and ± 21º. Conclusion: The Flexicurve is valid for assessing maximum flexion and extension of the thoracic spine, and maximum flexion of the lumbar spine. We suggest caution in evaluating the maximum extension of the lumbar spine.


Resumo Introdução: Problemas na coluna vertebral são frequentes, sendo a avaliação da flexibilidade uma informação relevante a ser considerada pelo profissional. Métodos alternativos para realizar avaliação da flexibilidade da coluna carecem de validação. Objetivo: Avaliar a validade concorrente do Flexicurva utilizando a videogrametria 3D como medida de referência, para a avaliação da flexibilidade em flexão e extensão da coluna vertebral torácica e lombar. Método: A amostra consecutiva contou com 39 indivíduos com idades entre 18 e 50 anos. Duas avaliações consecutivas foram realizadas pelo mesmo avaliador no mesmo dia e local: (1) Flexicurva e (2) videogrametria 3D. As avaliações foram realizadas com a coluna na posição neutra, seguida das posições de flexão e extensão máximas. A ADM nas posições de flexão e extensão máximas foram calculadas no MATLAB®, sendo definida como a diferença entre os ângulos máximos de flexão ou extensão e a angulação da posição neutra. Na análise estatística utilizou-se: Teste de Correlação Produto-Momento de Pearson, Erro RMS e Análise de Bland-Altman. (α < 0,05). Resultados: Os valores de ADM entre os instrumentos foram similares, com correlações altas para a flexão torácica (r = 0,751), extensão torácica (r = 0,814) e para flexão lombar (r = 0,853), com erros RMS inferiores a 8°. Para a extensão lombar a correlação foi moderada (r = 0,613), com erro RMS superior a 10°. Limites de concordância variaram entre ± 10º e ± 21º. Conclusão: O Flexicurva mostrou-se válido para avaliar o movimento flexão máxima e extensão máxima da coluna torácica, e flexão máxima da coluna lombar. Sugerimos cautela na avaliação da extensão máxima da coluna lombar.


Resumen Introducción: Los problemas en la columna vertebral son frecuentes, siendo la evaluación de la flexibilidad de la columna vertebral una información relevante a ser considerada por el profesional. Los métodos alternativos para realizar la evaluación de la flexibilidad de la columna necesitan validación. Objetivo: Evaluar la validez concurrente del Flexicurva utilizando la videogrametría 3D como medida de referencia para evaluar la flexión y extensión de la columna en las regiones lumbar y torácica. Método: La muestra consecutiva consistió en 39 individuos de edades comprendidas entre 18 y 50 años. El mismo evaluador realizó dos evaluaciones consecutivas en el mismo día y local: (1) Flexicurve (2) Videogrametría 3D. Las evaluaciones se realizaron con la columna en posición neutral seguida de la máxima flexión y extensión. El RDM en la posición máxima de flexión y extensión se calculó en MATLAB®, la flexión máxima y la extensión se definieron como la diferencia entre el ángulo de la posición con respecto al punto neutro. Los análisis estadísticos consistieron en la prueba de correlación de producto-momento de Pearson, error de RMS y los análisis de Bland-Altman (α < 0,05). Resultados: Los valores de RDM entre instrumentos fueron similares, con altas correlaciones para flexión torácica (r = 0.751), extensión torácica (r = 0.814) y flexión lumbar (r = 0.853), y errores RMS por debajo de 8°. Para la extensión lumbar, se moderó la correlación (r = 0,613) y el error RMS fue superior a 10°. Los límites de concordancia variaron entre ± 10º y ± 21º. Conclusión: El Flexicurva se mostró válido para evaluar la flexión máxima y la extensión máxima de la columna torácica, y la flexión máxima de la columna lumbar. Sugerimos precaución al evaluar la extensión máxima de la columna lumbar.


Asunto(s)
Humanos , Adulto , Columna Vertebral , Docilidad , Equipos de Medición de Riesgos , Estudio de Validación
7.
Rev. panam. salud pública ; 44: e88, 2020. tab, graf
Artículo en Español | LILACS | ID: biblio-1127118

RESUMEN

RESUMEN La hipertensión arterial es una causa modificable muy prevalente de enfermedades cardiovasculares, accidentes cerebrovasculares y muerte. Medir con exactitud la presión arterial es fundamental, dado que un error de medición de 5 mmHg puede ser motivo para clasificar incorrectamente como hipertensas a 84 millones de personas en todo el mundo. En la presente declaración de posición se resumen los procedimientos para optimizar el desempeño del observador al medir la presión arterial en el consultorio, con atención especial a los entornos de ingresos bajos o medianos, donde esta medición se ve complicada por limitaciones de recursos y tiempo, sobrecarga de trabajo y falta de suministro eléctrico. Es posible reducir al mínimo muchos errores de medición con una preparación adecuada de los pacientes y el uso de técnicas estandarizadas. Para simplificar la medición y prevenir errores del observador, deben usarse tensiómetros semiautomáticos o automáticos de manguito validados, en lugar del método por auscultación. Pueden ayudar también la distribución de tareas, la creación de un área específica de medición y el uso de aparatos semiautomáticos o de carga solar. Es fundamental garantizar la capacitación inicial y periódica de los integrantes del equipo de salud. Debe considerarse la implementación de programas de certificación de bajo costo y fácilmente accesibles con el objetivo de mejorar la medición de la presión arterial.(AU)


ABSTRACT High blood pressure (BP) is a highly prevalent modifiable cause of cardiovascular disease, stroke, and death. Accurate BP measurement is critical, given that a 5-mmHg measurement error may lead to incorrect hypertension status classification in 84 million individuals worldwide. This position statement summarizes procedures for optimizing observer performance in clinic BP measurement, with special attention given to low-tomiddle- income settings, where resource limitations, heavy workloads, time constraints, and lack of electrical power make measurement more challenging. Many measurement errors can be minimized by appropriate patient preparation and standardized techniques. Validated semi-automated/automated upper arm cuff devices should be used instead of auscultation to simplify measurement and prevent observer error. Task sharing, creating a dedicated measurement workstation, and using semi-automated or solar-charged devices may help. Ensuring observer training, and periodic re-training, is critical. Low-cost, easily accessible certification programs should be considered to facilitate best BP measurement practice.(AU)


RESUMO A hipertensão é uma causa altamente prevalente de doença cardiovascular, acidente vascular cerebral e morte. A medição precisa da pressão arterial (PA) é um aspecto crítico, uma vez que erros de mensuração da ordem de 5 mmHg podem levar a uma classificação incorreta do status de hipertensão em 84 milhões de pessoas em todo o mundo. O presente posicionamento resume os procedimentos para otimizar o desempenho do observador (o indivíduo responsável pela mensuração da PA) na mensuração clínica da PA, com atenção especial para contextos de baixa a média renda, onde recursos limitados, cargas de trabalho pesadas, restrições de tempo e falta de energia elétrica tornam mais desafiadora a tarefa de medir a PA. Muitos erros de mensuração podem ser minimizados pela preparação adequada do paciente e pelo uso de técnicas padronizadas. Para simplificar a mensuração e evitar erros do observador, devem-se utilizar dispositivos semiautomatizados ou automatizados validados, com manguito para braço, ao invés de auscultação. O compartilhamento de tarefas, a criação de uma estação de trabalho dedicada à mensuração e o uso de dispositivos semiautomatizados ou com carga solar podem ajudar. É essencial que seja assegurado o treinamento e retreinamento periódico do observador. Programas de certificação de baixo custo e de fácil acesso devem ser considerados para facilitar a adoção das melhores práticas na mensuração da PA.(AU)


Asunto(s)
Humanos , Oscilometría , Monitores de Presión Sanguínea/provisión & distribución , Salud Global/tendencias , Equipos de Medición de Riesgos , Hipertensión/prevención & control
8.
Artículo en Español | LILACS, SaludCR | ID: biblio-1389052

RESUMEN

Resumen Objetivo: Diseñar y validar un instrumento para vigilar los factores de riesgo de enfermedad cardiovascular en la población del cantón central de Cartago. Introducción: La vigilancia epidemiológica es un proceso regular y continuo de observar e investigar la morbi mortalidad y sus factores de riesgo para su análisis, interpretación y uso. La enfermedad cardiovascular es la principal causa de muerte en la mayoría de los países del mundo siendo necesario vigilar sus factores de riesgo. Métodos: Basado en una estrategia de medición y análisis integral de la mayoría de los factores de riesgo cardiovascular, se diseñó y validó un método para su vigilancia. Resultados: El método se ha aplicado en 6 empresas, 13 escuelas y colegios, 13 comunidades y 13 instituciones y asociaciones para un total de 2940 personas, con los resultados siguientes; sedentarismo 69.30%, obesidad 59.4%, enfermedad cardiovascular familiar 52.4%, padecer diabetes, hipertensión y/o colesterol alto 46.2%, estrés 39.65%, presión arterial alta 29.5%, colesterol total alto 31.0%, tabaquismo 17%, glicemia alta 2.7% y evento cardiovascular anterior 0.2%. Discusión: La vigilancia epidemiológica es básica para promover la salud y prevenir la enfermedad cardiovascular. El reto es contar con una metodología de bajo costo, buena confiabilidad y alta aceptación por los usuarios y colaboradores en la vigilancia. El método ha permitido medir y valorar los factores de riesgo cardiovascular satisfaciendo en buena manera los criterios indicados anteriormente.


Abstract Aim: Design and validate an instrument to survey el cardiovascular disease´s risk factors in the population of the city of Cartago. Introduction: Epidemiological surveillance is a steady and continuous process of observation and researching of the morbidity and mortality and its risk factors for analyzing, interpreting and using the information. Cardiovascular disease is the main cause of death in most countries in the world, being required to survey its risk factors. Methods: Based on a strategy of mesurement and comprehensive analysis of most cardiovascular risk factors, it was designed and validated a method for its surveillance. Results: The method has been employed in 6 companies, 13 primary and secundary schools, 13 communities and 13 institutions and associations, suming a total of 2949 people. It was obtained the following: 69.3% sedentary lifestyle, 59.4% obesity, 52.4% relatives cardiovascular disease, 46.2% diagnosed diabetes, hypertension and/or elevated colesterol, 39.65% stress, 29.5% hypertension at the moment of the survey, 31.0% high total colesterol at the moment of the survey, 17% smoking, 2.7% high blood glucose level and 0.2% a previous cardiovascular event. Discussion: Epidemiological surveillance is basic for promoting health and avoiding cardiovascular disease. The challenge is to count on a low cost, good reliability and high users and colaborators acceptance methodology. The method has allowed to mesure and assess the cardiovascular risk factors, satisfying properly the guidelines mentioned above.


Asunto(s)
Humanos , Ejercicio Físico/fisiología , Equipos de Medición de Riesgos , Factores de Riesgo de Enfermedad Cardiaca , Costa Rica
9.
Braz. arch. biol. technol ; Braz. arch. biol. technol;62: e19180372, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1001421

RESUMEN

Abstract The objective of this study was to construct and validate an instrument that evaluates the Quality of Work Life (QWL) globally, following the WHOQOL instruments and founded in QWL's classical theoretical models, directed to the contemporary society. The psychometric properties tested were content validity, face validity, internal consistency, criterion validity, concurrent validity and test-retest reliability in an application to 283 individuals. The final version of the instrument is constituted by 47 questions, being five to sample knowledge and 42 divided in five spheres that contemplate QWL's dimensions. For the results calculation a SPSS syntax and a tool in Microsoft Excel that perform the automated calculation after the data tabulation were developed. The psychometric properties tested were satisfactory. We conclude that the goal of validating a global instrument for evaluation of QWL from the contemporary society culture with satisfactory psychometrical characteristics was reached.


Asunto(s)
Calidad de Vida , Psicometría/métodos , Equipos de Medición de Riesgos
10.
Braz. arch. biol. technol ; Braz. arch. biol. technol;61(spe): e18000032, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-974157

RESUMEN

ABSTRACT The present work presents the development of a system of measurement of electric energy consumption. This system shows the consumer the amount of energy consumed and its respective monetary value in real time. The prototype was used in a case study to validate its operation. Data were collected to discuss the results obtained. In order to verify if the results obtained in the prototype were correct, several measurements of energy consumption were made in different residential equipment. The consumption values measured by the prototype were compared with the values obtained by the certified and calibrated energy meter provided by COPEL and were satisfactory.


Asunto(s)
Equipos de Medición de Riesgos , Electricidad , Abastecimiento de Energía/métodos , Consumo de Energía
11.
Bol. Inst. Pesca (Impr.) ; 43(4): 557-568, Oct.-Dec.2017. graf
Artículo en Inglés | VETINDEX | ID: biblio-1465288

RESUMEN

The efficacy of a point-of-care (POC) blood glucometer (Accu-Chek Active®) was evaluated in adult lambaris (Astyanax altiparanae), comparing the values obtained by this equipment to those obtained by the laboratory enzymatic method. The glycemia of adult males and females and the variations resulting from transporting in juveniles were also evaluated 0, 1, 24, 48 and 72 hours after procedure. Data were submitted to ANOVA, comparing the means by the Tukey´s Test (P> 0.05) and a regression analysis was performed to establish the correlations between values obtained by the two methods. The blood glucose values obtained by POC meter were 11.2% lower, in absolute terms, but did not differ significantly from those recorded by the laboratory enzymatic method, with linear correlation (R = 67.7%) between the methods. Higher glucose levels were recorded for males; glycemia increased 334.3% immediately after transportation, remained elevated (113.3%) up to 48 hours and returned to basal levels (fasting) after 72 hours. It was concluded that POC Accu-Chek Active® is an effective tool for glucose determination in lambari; there are sex-dependent differences in relation to blood glucose levels; the species is sensitive to stress transporting and glycemia is an immediate and appropriate physiological indicator for this evaluation.


A eficácia do medidor portátil de glicemia (Accu-Chek Active®) foi avaliada em lambaris adultos (Astyanax altiparanae), comparando-se os valores registrados com os obtidos por meio do método enzimático laboratorial. A glicemia de machos e fêmeas adultos e as variações decorrentes do transporte em juvenis também foram avaliadas 0, 1, 24, 48 e 72 horas após o procedimento. Os dados foram submetidos à ANOVA, comparando-se as médias pelo Teste de Tukey (P> 0,05), realizando-se posterior análise de regressão para estabelecimento das correlações entre os valores obtidos pelos dois métodos. Os valores de glicemia obtidos pelo glicosímetro foram 11,2% menores, em termos absolutos, mas não diferiram daqueles registrados pelo método laboratorial, observando-se correlação linear (R = 67,7%) entre ambos. Maiores concentrações de glicose foram registradas para os machos; a glicemia aumentou 334,3% imediatamente após o transporte, permaneceu elevada (113,3%) até 48 horas e retornou aos níveis basais (jejum) após 72 horas. Concluiu-se que o glicosímetro portátil Accu-Chek Active® é uma ferramenta eficaz para a determinação da glicose em lambari; existem diferenças dependentes do sexo em relação aos níveis de glicose no sangue; a espécie é sensível ao estresse de transporte, sendo a glicose um indicador fisiológico imediato e apropriado para esta avaliação.


Asunto(s)
Animales , Characiformes/sangre , Distribución por Sexo , Equipos de Medición de Riesgos , Estrés Psicológico/sangre , Índice Glucémico
12.
B. Inst. Pesca ; 43(4): 557-568, Oct.-Dec.2017. graf
Artículo en Inglés | VETINDEX | ID: vti-18246

RESUMEN

The efficacy of a point-of-care (POC) blood glucometer (Accu-Chek Active®) was evaluated in adult lambaris (Astyanax altiparanae), comparing the values obtained by this equipment to those obtained by the laboratory enzymatic method. The glycemia of adult males and females and the variations resulting from transporting in juveniles were also evaluated 0, 1, 24, 48 and 72 hours after procedure. Data were submitted to ANOVA, comparing the means by the Tukey´s Test (P> 0.05) and a regression analysis was performed to establish the correlations between values obtained by the two methods. The blood glucose values obtained by POC meter were 11.2% lower, in absolute terms, but did not differ significantly from those recorded by the laboratory enzymatic method, with linear correlation (R = 67.7%) between the methods. Higher glucose levels were recorded for males; glycemia increased 334.3% immediately after transportation, remained elevated (113.3%) up to 48 hours and returned to basal levels (fasting) after 72 hours. It was concluded that POC Accu-Chek Active® is an effective tool for glucose determination in lambari; there are sex-dependent differences in relation to blood glucose levels; the species is sensitive to stress transporting and glycemia is an immediate and appropriate physiological indicator for this evaluation.(AU)


A eficácia do medidor portátil de glicemia (Accu-Chek Active®) foi avaliada em lambaris adultos (Astyanax altiparanae), comparando-se os valores registrados com os obtidos por meio do método enzimático laboratorial. A glicemia de machos e fêmeas adultos e as variações decorrentes do transporte em juvenis também foram avaliadas 0, 1, 24, 48 e 72 horas após o procedimento. Os dados foram submetidos à ANOVA, comparando-se as médias pelo Teste de Tukey (P> 0,05), realizando-se posterior análise de regressão para estabelecimento das correlações entre os valores obtidos pelos dois métodos. Os valores de glicemia obtidos pelo glicosímetro foram 11,2% menores, em termos absolutos, mas não diferiram daqueles registrados pelo método laboratorial, observando-se correlação linear (R = 67,7%) entre ambos. Maiores concentrações de glicose foram registradas para os machos; a glicemia aumentou 334,3% imediatamente após o transporte, permaneceu elevada (113,3%) até 48 horas e retornou aos níveis basais (jejum) após 72 horas. Concluiu-se que o glicosímetro portátil Accu-Chek Active® é uma ferramenta eficaz para a determinação da glicose em lambari; existem diferenças dependentes do sexo em relação aos níveis de glicose no sangue; a espécie é sensível ao estresse de transporte, sendo a glicose um indicador fisiológico imediato e apropriado para esta avaliação.(AU)


Asunto(s)
Animales , Characiformes/sangre , Índice Glucémico , Estrés Psicológico/sangre , Equipos de Medición de Riesgos , Distribución por Sexo
13.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1551-1559, Nov.-Dez. 2017. ilus, graf
Artículo en Portugués | VETINDEX | ID: vti-735003

RESUMEN

O objetivo deste estudo foi utilizar a sonda uretral flexível como método alternativo para aferição da pressão intracraniana em coelhos com trauma cranioencefálico induzido pelo cateter de Fogarty 4 Fr (balão epidural) e comparar os dados obtidos com o método convencional de cateter de ventriculostomia. Foram utilizados 12 coelhos, machos, adultos, distribuídos aleatoriamente em dois grupos, denominados de G1: mensuração da PIC com cateter de ventriculostomia (n=6) e G2: mensuração com sonda uretral (n=6). Foram realizadas duas craniotomias na região parietal direita e esquerda para a implantação do cateter de ventriculostomia ou sonda uretral flexível e o balão epidural, respectivamente. A PAM, a PPC, a FC, a FR e a TR foram mensurados antes e após a craniotomia. A PIC foi avaliada após a craniotomia e a cada 10 minutos depois do preenchimento do balonete com 0,3mL de NaCl 0,9%, durante 40 minutos, e com 0,6mL, pelo mesmo período de tempo, totalizando 80 minutos. A PIC aumentou em ambos os grupos, sendo menores os valores registrados com a sonda uretral flexível. Foi possível reproduzir o aumento da PIC com o modelo experimental de TCE utilizando o cateter de Fogarty 4 Fr na região epidural e, embora haja a necessidade de outros estudos, a sonda uretral flexível demonstra ser um método alternativo de mensuração da PIC em coelhos com trauma cranioencefálico.(AU)


The aim of this study was to evaluate the use of flexible urethral catheter as an alternative method for measuring intracranial pressure in rabbits with head trauma induced by 4 F Fogarty catheter (epidural balloon) and compare the data obtained with the conventional method of ventriculostomy catheter. In this study, New Zealand rabbits were randomly distributed into two groups, G1: measuring the ICP with ventriculostomy catheter (n=6) and G2: measuring the ICP with urethral catheter (n=6). Two craniotomies were performed in the right and left parietal region for the implantation of a ventriculostomy catheter and/or flexible urethral catheter and epidural 4 Fr Fogarty arterial embolectomy catheter, respectively. MAP, CPP, HR, RF and RT values were measured before and after of the craniotomy. The ICP value was measured after craniotomy, every five minutes during 40 minutes after the balloon was inflated with 0.3 ml with NaCl and further 40 minutes after the balloon was inflated with 0.6 ml. The ICP value increased in both groups; however, the ICP values were lower in the flexible urethral catheter. The flexible urethral catheter can be used as an alternative method to measure ICP values in rabbits with head injury.(AU)


Asunto(s)
Animales , Conejos , Presión Intracraneal , Equipos de Medición de Riesgos , Cateterismo Urinario , Cateterismo Urinario/veterinaria , Traumatismos Craneocerebrales/diagnóstico , Ventriculostomía/veterinaria
14.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1551-1559, nov.-dez. 2017. ilus, graf
Artículo en Portugués | LILACS, VETINDEX | ID: biblio-910563

RESUMEN

O objetivo deste estudo foi utilizar a sonda uretral flexível como método alternativo para aferição da pressão intracraniana em coelhos com trauma cranioencefálico induzido pelo cateter de Fogarty 4 Fr (balão epidural) e comparar os dados obtidos com o método convencional de cateter de ventriculostomia. Foram utilizados 12 coelhos, machos, adultos, distribuídos aleatoriamente em dois grupos, denominados de G1: mensuração da PIC com cateter de ventriculostomia (n=6) e G2: mensuração com sonda uretral (n=6). Foram realizadas duas craniotomias na região parietal direita e esquerda para a implantação do cateter de ventriculostomia ou sonda uretral flexível e o balão epidural, respectivamente. A PAM, a PPC, a FC, a FR e a TR foram mensurados antes e após a craniotomia. A PIC foi avaliada após a craniotomia e a cada 10 minutos depois do preenchimento do balonete com 0,3mL de NaCl 0,9%, durante 40 minutos, e com 0,6mL, pelo mesmo período de tempo, totalizando 80 minutos. A PIC aumentou em ambos os grupos, sendo menores os valores registrados com a sonda uretral flexível. Foi possível reproduzir o aumento da PIC com o modelo experimental de TCE utilizando o cateter de Fogarty 4 Fr na região epidural e, embora haja a necessidade de outros estudos, a sonda uretral flexível demonstra ser um método alternativo de mensuração da PIC em coelhos com trauma cranioencefálico.(AU)


The aim of this study was to evaluate the use of flexible urethral catheter as an alternative method for measuring intracranial pressure in rabbits with head trauma induced by 4 F Fogarty catheter (epidural balloon) and compare the data obtained with the conventional method of ventriculostomy catheter. In this study, New Zealand rabbits were randomly distributed into two groups, G1: measuring the ICP with ventriculostomy catheter (n=6) and G2: measuring the ICP with urethral catheter (n=6). Two craniotomies were performed in the right and left parietal region for the implantation of a ventriculostomy catheter and/or flexible urethral catheter and epidural 4 Fr Fogarty arterial embolectomy catheter, respectively. MAP, CPP, HR, RF and RT values were measured before and after of the craniotomy. The ICP value was measured after craniotomy, every five minutes during 40 minutes after the balloon was inflated with 0.3 ml with NaCl and further 40 minutes after the balloon was inflated with 0.6 ml. The ICP value increased in both groups; however, the ICP values were lower in the flexible urethral catheter. The flexible urethral catheter can be used as an alternative method to measure ICP values in rabbits with head injury.(AU)


Asunto(s)
Animales , Conejos , Presión Intracraneal , Equipos de Medición de Riesgos , Cateterismo Urinario/estadística & datos numéricos , Cateterismo Urinario/veterinaria , Traumatismos Craneocerebrales/diagnóstico , Ventriculostomía/veterinaria
15.
ImplantNewsPerio ; 2(5): 868-873, set.-out. 2017. ilus, tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-877282

RESUMEN

Objetivo: avaliar, por meio de extensometria, a transmissão da carga mastigatória axial ao osso de suporte em próteses unitárias implantossuportadas por implantes de diferentes comprimentos. Material e métodos: em um bloco de poliuretano que simula 2 mm de osso cortical e o restante de medular, segundo a norma ASTM­F1839, com 22 mm x 16 mm x 150 mm, foram instalados quatro implantes cone-morse infraósseos 2 mm: G1) 4 mm x 7 mm; G2) 4 mm x 9 mm; G3) 4 mm x 11 mm; G4) 4 mm x 13 mm. Sobre os mesmos, foram instalados pilares do tipo esteticone e cilindros metálicos. Dois extensômetros lineares foram colados na superfície do bloco, tangenciando a plataforma de cada implante (mesial e distal). Em uma máquina de ensaio universal, foi aplicada uma carga de 100 N sobre a superfície oclusal de cada cilindro. Para cada grupo, foram realizados cinco medições e os dados obtidos em microdeformacão (µÆ). Foi verificada a normalidade dos dados pelo teste de Shapiro-Wilk e realizada a análise de variância 1 critério (p < 0,05), e o teste Tukey (p  0,5). Resultados: as médias e os desvios-padrão das amostras foram, respectivamente, G1: 346.16,3 ± 10,28 µÆ; G2: 216.91 ± 15,47 µÆ; G3: 114,41 ± 2,33 µÆ; e G4: 76.83,3 ± 7,13 µÆ. O teste de Shapiro-Wilk constatou a normalidade dos dados, e os testes Anova e Turkey a diferença estatística significante entre todos os grupos. Conclusão: para cargas axiais, implantes com menor comprimento produziram maior deformação no osso superfi cial.


Purpose: the aim of this study was to evaluate, by extensometry, the transmission of the axial masticatory load to supporting bone around implants of different lengths. Material and methods: in a block of polyurethane that simulates 2 mm of cortical bone and the remaing of medullary bone, according to the ASTM-F1839 standard, with 22 mm x 16 mm x 150 mm, were installed 4 morse tappered dental implants, 2 mm subcrestal: G1) 4 mm x 7 mm; G2) 4 mm x 9 mm; G3) 4 mm x 11 mm; G4) 4 mm x 13 mm. Estheticone-like abutments and metallic cylinders were placed. Two linear strain gauges were bonded on block surface, tangential to the platform of each implant (mesial and distal). A 100 N load on the occlusal surface of each cylinder was applied to a universal test machine. For each group, five measurements and the data obtained in microdeformation (µÆ) were performed. The normality of the data was verified by the Shapiro-Wilk test and (p < 0.05) and Tukey's test (p  0.5). Results: the means and standard deviation of the samples were respectively G1: 346.16.3 ± 10.28 µÆ; G2: 216.91 ± 15.47 µÆ; G3: 114.41 ± 2.33 µÆ; G4: 76.83.3 ± 7.13 µÆ. The Shapiro-Wilk test exhibit the normality of the data, and the Anova and Turkey tests exhibit statistically significant difference between all groups. Conclusion: axial load produced more tension for short implants on the superficial bone.


Asunto(s)
Humanos , Análisis de Varianza , Fenómenos Biomecánicos , Fuerza de la Mordida , Implantación Dental , Análisis de Elementos Finitos , Equipos de Medición de Riesgos , Técnicas In Vitro
16.
Mem. Inst. Invest. Cienc. Salud (Impr.) ; 15(2): 108-117, ago. 2017. ilus, graf
Artículo en Español | LILACS, BDNPAR | ID: biblio-869112

RESUMEN

Un creciente reconocimiento de la importancia de la calidad de vida en odontología ha llevado al desarrollo de varios instrumentos para medir su relación con la salud bucodental. Saber por qué y de qué manera la salud bucodental afecta la calidad de vida de las personas es relevante para la práctica, la investigación y la enseñanza en odontología. El objetivo de esta revisión bibliográfica fue actualizar los conocimientos sobre las características generales y sicométricas de los instrumentos para medir la calidad de vida relacionada a la salud bucodental que surgieron posterior a la publicación en 1997 de los resultados de la conferencia "Measuring oral health and quality of life”. Se realizó una búsqueda bibliográfica para identificar publicaciones aparecidas de enero de 1998 a junio del 2011, utilizando las bases de datos MEDLINE y GOOGLE académico. Se establecieron criterios específicos, basados en marcos de referencia internacionales, para la inclusión, la recolección y el análisis de las propiedades generales y sicométricas de los instrumentos. Se identificaron 233 artículos de los cuales 10 cumplían con todos los criterios predeterminados y finalmente quedaron 9 porque uno de ellos se encontraba repetido. Todas las publicaciones fueron encontradas en lengua inglesa. Todos los instrumentos fueron multidimensionales, presentaron propiedades sicométricas adecuadas y la mayoría de ellos tomó como base a otros instrumentos de medición previos y a la clasificación de deficiencias y discapacidades. Se concluye que es necesario avanzar en la medición de salud bucodental relacionada a la calidad de vida para el contexto y las características de la población de América Latina ya que sólo se cuenta con publicaciones anglosajonas.


There is growing recognition of the importance of oral health-related quality of life.This has given rise to the development of various instruments to measure therelationship between quality of life and oral health. Understanding why and how oralhealth affects quality of life is highly relevant to the research, teaching and practice ofprofessional dentistry. The objective of this literature review was to update theknowledge about the general and psychometric characteristics of instruments tomeasure quality of life related to oral health that emerged after the publication in 1997of the results of the conference "Measuring oral health and quality of life”. We conducted a literature review using MEDLINE and GOOGLE Scholar databases to identifypublications that appeared between January, 1998 and June, 2011. We used commoninternational frames of reference to establish specific search criteria for the inclusion,collection, and analysis of the general and psychometric properties of the instruments.We identified 233 articles, ten of which met all the established criteria. Ultimately wereduced this number to nine because one of the articles was a duplicate. All identifiedarticles were in English. All instruments identified through the literature review weremultidimensional and had adequate psychometrtic properties. The majority ofinstruments was based on prior measurement tools and the classification of impairmentsand disabilities. We conclude that to advance the measurement of oral health-relatedquality of life, the specific context and characteristics of the Latin American populationshould be taken into account. So far, this topic has only been addressed in Englishlanguage publications.


Asunto(s)
Humanos , Calidad de Vida , Dispositivos para el Autocuidado Bucal , Equipos de Medición de Riesgos , Salud Pública
17.
Rev. cuba. oftalmol ; 30(1): 0-0, ene.-mar. 2017. graf
Artículo en Español | CUMED | ID: cum-73121

RESUMEN

La salud es un elemento decisivo de la calidad de vida. El concepto de calidad de vida es cada vez más utilizado como medida del bienestar y depende de elementos objetivos y de la valoración subjetiva que el paciente hace de diferentes aspectos de su vida. Las pruebas de calidad de vida son adaptables al campo de la Oftalmología y aplicables a cualquier paciente, además de las pruebas de función visual. El NEI VFQ-25 mide las dimensiones del estado de salud orientado a la visión. El uso de estos estudios permite conocer la respuesta clínica y el grado de satisfacción del paciente, lo que conlleva una mejor calidad de vida. Con la presente investigación se pretende mostrar una de las pruebas más utilizadas para describir los resultados de la calidad visual(AU)


The health is a decisive element of the life quality. The quality of life concept is more and more utilized, it depends on objective elements, and subjective opinion of the patient makes of different aspects of its life. The quality of life test is adaptive to the ophthalmology patient, beside the tests of visual function. The NEI VFQ-25, measures the dimensions from the health to the vision. The use of these studies allows knowing the clinical response and the patient satisfaction, what means a better life quality(AU)


Asunto(s)
Humanos , Equipos de Medición de Riesgos , Satisfacción del Paciente , Calidad de Vida , Pruebas del Campo Visual
19.
Int. j. cardiovasc. sci. (Impr.) ; 30(2): f:100-l:108, mar.-abr. 2017. tab
Artículo en Portugués | LILACS | ID: biblio-833892

RESUMEN

Fundamento: A hipertensão arterial é o principal fator de risco cardiovascular. A qualidade técnica dos esfigmomanômetros é condição fundamental para obtenção da correta medida da pressão arterial. Objetivos: Avaliar o perfil dos esfigmomanômetros disponíveis nos serviços de urgências de Belo Horizonte, Minas Gerais. Métodos: Realizamos um estudo transversal, observacional e não intervencionista para avaliar o perfil dos esfigmomanômetros disponíveis nos prontos atendimentos de adultos de hospitais públicos e privados do município de Belo Horizonte. Avaliamos 337 aparelhos de 25 hospitais, sendo 15 públicos (do total de 16) e 10 privados (do total de 12). Resultados: Foram observadas inadequações dos equipamentos em relação à validação pelo Instituto Nacional de Metrologia, Qualidade e Tecnologia ­ INMETRO, em 26% (88/337) dos equipamentos; calibração vencida em 39% (132/337) e não correspondência de marca aparelho/braçadeira em 54% (188/337). Em 13 dos 25 hospitais (52%), não havia disponibilidade de manguitos para braços de diferentes tamanhos além do padrão. Houve superioridade de adequação dos aparelhos aneroides e de mercúrio dos hospitais privados (p = 0,038 e p < 0,001, respectivamente) e dos eletrônicos nos públicos (p < 0,001). Conclusão: Conclui-se que 78% dos esfigmomanômetros disponíveis nos serviços de urgência/emergência de uma das maiores capitais brasileiras apresentavam inadequações técnicas, e em metade dos serviços não havia manguitos de diferentes tamanhos. Tal fato representa um alerta para a situação dos equipamentos disponíveis para atendimento da população no país


Background: Hypertension is the main risk factor for cardiovascular diseases. Technical quality of sphygmomanometers is a prerequisite for the correct measurement of arterial pressure. Objectives: To evaluate sphygmomanometers available in emergency services in the city of Belo Horizonte, Brazil. Methods: We performed a cross-sectional, observational, non-interventional study to evaluate characteristics of the sphygmomanometers available in adult emergency services of public and private hospitals in the city of Belo Horizonte, Brazil. We evaluated 337 sphygmomanometers of 25 hospitals ­ 15 (of 16) public hospitals and 10 (of 12) private hospitals. Results: Twenty-six percent (88/337) of devices were considered inadequate regarding the INMETRO (National Institute of Metrology, Quality and Technology) standards, 39.2% (132/337) for calibration dates, and 54% (188/337) for the mismatching between cuff's and device's brands. In 13 of 25 hospitals (52%), there were no spare cuffs in different sizes for different arm circumferences. Higher adequacy was found for aneroid and mercury sphygmomanometers used in private hospitals (p = 0.038 and p < 0.001, respectively) and electronic devices used in public hospitals (p < 0.001) compared with others.Conclusion: Seventy-eight percent of sphygmomanometers available in emergency services had technical inadequacies, and half of these services had no spare cuffs in different sizes available. These findings serve as a warning of the conditions of the equipment used in healthcare services provided to the general population in Brazil


Asunto(s)
Hospitales Privados/normas , Hospitales Públicos/normas , Hipertensión/complicaciones , Esfigmomanometros , Salud del Adulto , Enfermedades Cardiovasculares/fisiopatología , Vasos Coronarios/fisiología , Mantenimiento de Equipo/análisis , Mantenimiento de Equipo/métodos , Equipos de Medición de Riesgos , Estudio Observacional , Atención Primaria de Salud/métodos , Factores de Riesgo , Interpretación Estadística de Datos , Encuestas y Cuestionarios
20.
Rev. cuba. oftalmol ; 30(1): 0-0, ene.-mar. 2017. graf
Artículo en Español | LILACS | ID: biblio-901347

RESUMEN

La salud es un elemento decisivo de la calidad de vida. El concepto de calidad de vida es cada vez más utilizado como medida del bienestar y depende de elementos objetivos y de la valoración subjetiva que el paciente hace de diferentes aspectos de su vida. Las pruebas de calidad de vida son adaptables al campo de la Oftalmología y aplicables a cualquier paciente, además de las pruebas de función visual. El NEI VFQ-25 mide las dimensiones del estado de salud orientado a la visión. El uso de estos estudios permite conocer la respuesta clínica y el grado de satisfacción del paciente, lo que conlleva una mejor calidad de vida. Con la presente investigación se pretende mostrar una de las pruebas más utilizadas para describir los resultados de la calidad visual(AU)


The health is a decisive element of the life quality. The quality of life concept is more and more utilized, it depends on objective elements, and subjective opinion of the patient makes of different aspects of its life. The quality of life test is adaptive to the ophthalmology patient, beside the tests of visual function. The NEI VFQ-25, measures the dimensions from the health to the vision. The use of these studies allows knowing the clinical response and the patient satisfaction, what means a better life quality(AU)


Asunto(s)
Humanos , Equipos de Medición de Riesgos , Satisfacción del Paciente , Calidad de Vida , Pruebas del Campo Visual/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA