Medicina (B Aires) ; 80(1): 17-22, 2020.
Artículo en Español | MEDLINE | ID: mdl-32044737

RESUMEN

Infective endocarditis (IE) is a serious and potentially lethal condition. The diagnostic capacity of the modified Duke criteria is high for native valves, but it declines in the case of EI of prosthetic valves or EI associated with devices. Echocardiography and microbiological findings are essential for diagnosis but may be insufficient in this group of patients. Our objective was to evaluate the usefulness of positron emission tomography and fusion with computed tomography (PET / CT) in patients with suspected IE, carriers of prosthetic valves or intracardiac devices; 32 patients were studied, who underwent PET / CT with 18F-Fluorine deoxyglucose (18F-FDG). Those with intense focal and/or heterogeneous uptake with a Standard Uptake Value SUV) cut-off point greater than or equal to 3.7 were considered suggestive of infection. The initial diagnoses according to the modified Duke criteria were compared with the final diagnosis established by the Institutional Endocarditis Unit. The addition of PET / CT to these criteria, provided a conclusive diagnosis in 22 of the 32 initial cases reclassifying 11 cases in definitive EI; another 5 cases were negative for that diagnosis. EI continues to be a serious clinical problem. In those cases where the Duke criteria are not sufficient to establish the diagnosis and clinical suspicion persists, PET / CT can be a useful complementary tool to increase the diagnostic sensitivity.


La endocarditis infecciosa (EI) es una enfermedad grave y potencialmente letal. La capacidad diagnóstica de los criterios de Duke modificados es alta para válvulas nativas, pero decae en el caso de EI de válvulas protésicas o EI asociadas a dispositivos. El ecocardiograma y los hallazgos microbiológicos son fundamentales para el diagnóstico, pero pueden resultar insuficientes en este grupo de pacientes. Nuestro objetivo fue evaluar la utilidad de la tomografía por emisión de positrones y fusión con tomografía computarizada (PET/TC) en pacientes con sospecha de EI, portadores de válvulas protésicas o dispositivos intracardiacos. Se estudiaron 32 pacientes, a los cuales se les realizó un PET/CT con 18F-Flúor desoxiglucosa (18F-FDG). Se consideraron sugestivos de infección aquellos con captación intensa de tipo focal y/o heterogénea con un punto de corte de Standard Uptake Value (SUV) mayor o igual a 3.7. Los diagnósticos iniciales según los criterios de Duke modificados, se compararon con el diagnóstico final establecido por la Unidad de Endocarditis institucional. El agregado del PET/CT a esos criterios, proporcionó un diagnóstico concluyente en 22 de los 32 casos iniciales, reclasificando a 11 casos en EI definitivas y a otros 5 casos como negativos para ese diagnóstico. La EI continúa siendo un grave problema clínico. En aquellos casos donde los criterios de Duke no son suficientes para establecer el diagnóstico y la sospecha clínica persiste, el PET/CT puede ser una herramienta complementaria útil para aumentar la sensibilidad diagnóstica.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Endocarditis/diagnóstico por imagen , Endocarditis/microbiología , Prótesis Valvulares Cardíacas/efectos adversos , Marcapaso Artificial/efectos adversos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/microbiología , Femenino , Fluorodesoxiglucosa F18 , Prótesis Valvulares Cardíacas/microbiología , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/microbiología , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadísticas no Paramétricas , Adulto Joven
2.
Medicina (B.Aires) ; Medicina (B.Aires);80(1): 17-22, feb. 2020. ilus, tab
Artículo en Español | LILACS | ID: biblio-1125033

RESUMEN

La endocarditis infecciosa (EI) es una enfermedad grave y potencialmente letal. La capacidad diagnóstica de los criterios de Duke modificados es alta para válvulas nativas, pero decae en el caso de EI de válvulas protésicas o EI asociadas a dispositivos. El ecocardiograma y los hallazgos microbiológicos son fundamentales para el diagnóstico, pero pueden resultar insuficientes en este grupo de pacientes. Nuestro objetivo fue evaluar la utilidad de la tomografía por emisión de positrones y fusión con tomografía computarizada (PET/TC) en pacientes con sospecha de EI, portadores de válvulas protésicas o dispositivos intracardiacos. Se estudiaron 32 pacientes, a los cuales se les realizó un PET/CT con 18F-Flúor desoxiglucosa (18F-FDG). Se consideraron sugestivos de infección aquellos con captación intensa de tipo focal y/o heterogénea con un punto de corte de Standard Uptake Value (SUV) mayor o igual a 3.7. Los diagnósticos iniciales según los criterios de Duke modificados, se compararon con el diagnóstico final establecido por la Unidad de Endocarditis institucional. El agregado del PET/CT a esos criterios, proporcionó un diagnóstico concluyente en 22 de los 32 casos iniciales, reclasificando a 11 casos en EI definitivas y a otros 5 casos como negativos para ese diagnóstico. La EI continúa siendo un grave problema clínico. En aquellos casos donde los criterios de Duke no son suficientes para establecer el diagnóstico y la sospecha clínica persiste, el PET/CT puede ser una herramienta complementaria útil para aumentar la sensibilidad diagnóstica.


Infective endocarditis (IE) is a serious and potentially lethal condition. The diagnostic capacity of the modified Duke criteria is high for native valves, but it declines in the case of EI of prosthetic valves or EI associated with devices. Echocardiography and microbiological findings are essential for diagnosis but may be insufficient in this group of patients. Our objective was to evaluate the usefulness of positron emission tomography and fusion with computed tomography (PET / CT) in patients with suspected IE, carriers of prosthetic valves or intracardiac devices; 32 patients were studied, who underwent PET / CT with 18F-Fluorine deoxyglucose (18F-FDG). Those with intense focal and/or heterogeneous uptake with a Standard Uptake Value (SUV) cut-off point greater than or equal to 3.7 were considered suggestive of infection. The initial diagnoses according to the modified Duke criteria were compared with the final diagnosis established by the Institutional Endocarditis Unit. The addition of PET / CT to these criteria, provided a conclusive diagnosis in 22 of the 32 initial cases reclassifying 11 cases in definitive EI; another 5 cases were negative for that diagnosis. EI continues to be a serious clinical problem. In those cases where the Duke criteria are not sufficient to establish the diagnosis and clinical suspicion persists, PET / CT can be a useful complementary tool to increase the diagnostic sensitivity.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Marcapaso Artificial/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Desfibriladores Implantables/efectos adversos , Endocarditis/microbiología , Endocarditis/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Marcapaso Artificial/microbiología , Valores de Referencia , Prótesis Valvulares Cardíacas/microbiología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Desfibriladores Implantables/microbiología , Estadísticas no Paramétricas , Fluorodesoxiglucosa F18
3.
Int J Infect Dis ; 38: 54-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26216762

RESUMEN

OBJECTIVES: The clinical utility of sonication as an adjunctive diagnostic tool for the microbial diagnosis of cardiac implantable device-associated infections (CIDAIs) was investigated. METHODS: The implants of 83 subjects were investigated, 15 with a CIDAI and 68 without a clinical infection. Clinical data were analyzed prospectively and sonication fluid cultures (83 patients, 100%) and traditional cultures (31 patients, 37.4%) were performed RESULTS: Generator pocket infection and device-related endocarditis were found in 13 (86.7%) and four (26.7%) subjects, respectively. The mean numbers of previous technical complications and infections were higher in the infected patients compared to the non-infected patients (8 vs. 1, p<0.001; 2 vs. 0, p<0.031, respectively). The sensitivity and specificity for detecting CIDAI was 73.3% (11/15) and 48.5% (33/68) for sonication fluid culture, and 26.7% (4/15) and 100% (16/16) for traditional culture (p<0.001), respectively. A higher number of organisms were identified by sonication fluid than by tissue culture (58 vs. 4 specimens; p<0.001). The most frequent organisms cultured were Gram-positive cocci (66.1%), mainly coagulase-negative staphylococci (35.5%). Thirty-five (51.5%) non-infected subjects were considered colonized due to the positive identification of organisms exclusively through sonication fluid culture. CONCLUSIONS: Sonication fluid culture from the removed cardiac implants has the potential to improve the microbiological diagnosis of CIDAIs.


Asunto(s)
Desfibriladores Implantables/microbiología , Endocarditis Bacteriana/diagnóstico , Marcapaso Artificial/microbiología , Infecciones Relacionadas con Prótesis/diagnóstico , Sonicación , Adulto , Anciano , Anciano de 80 o más Años , Endocarditis Bacteriana/microbiología , Femenino , Cocos Grampositivos/aislamiento & purificación , Humanos , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/microbiología , Sensibilidad y Especificidad , Staphylococcus/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA