Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 531
Filtrar
1.
BMC Ophthalmol ; 24(1): 381, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198787

RESUMEN

OBJECTIVE: Trabeculectomy and non-penetrating trabecular surgery are common operations for glaucoma. This meta-analysis aims to compare the effect of trabeculectomy and non-penetrating trabecular surgery in postoperative astigmatism of patients with glaucoma. METHODS: A systematic literature search was performed for studies comparing trabeculectomy and non-penetrating trabecular surgery in patients with glaucoma. The time frame for the search was from the time of construction to April 2024. There were no restrictions regarding study type or type of glaucoma. The endpoint was the surgically induced astigmatism assessed 6 months after operation. We conducted this meta-analysis following the PRISMA (Preferred Reporting Items for Systematic Review and Meta-Analysis). RESULTS: Five eligible studies were included in this meta-analysis and presented data for 359 eyes with various types of glaucoma at different stages. The results revealed an increase in astigmatism in patients with glaucoma after trabeculectomy and non-penetrating trabecular surgery. Trabeculectomy had a higher incidence of astigmatism than in the non-penetrating trabecular surgery group at or around 6 months postoperatively, and the difference was statistically significant. (SMD = 0.40, 95% CI = 0.19 to 0.61, P = 0.02). CONCLUSION: Our results demonstrated that both trabeculectomy and non-penetrating trabecular surgery could increase astigmatism until 6 months after operation. Moreover, non-penetrating trabecular surgery group seems to have less influence on astigmatism. TRIAL REGISTRATION NUMBER: CRD42024517708.


Asunto(s)
Astigmatismo , Glaucoma , Complicaciones Posoperatorias , Trabeculectomía , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiología , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Cirugía Filtrante/efectos adversos , Cirugía Filtrante/métodos , Glaucoma/cirugía , Glaucoma/fisiopatología , Presión Intraocular/fisiología , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Trabeculectomía/métodos , Trabeculectomía/efectos adversos , Agudeza Visual/fisiología
2.
Curr Opin Ophthalmol ; 35(5): 409-414, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39082111

RESUMEN

PURPOSE OF REVIEW: The advent of minimally invasive glaucoma surgery (MIGS) procedures has ushered in a new era of interventional glaucoma. MIGS has expanded the treatment options for surgeons necessitating a rethinking of the optimal management strategy for patients with glaucoma. RECENT FINDINGS: There are several new MIGS devices and procedures available to glaucoma surgeons. With several options available, patient selection is crucial to maximize the utility of MIGS in the context of traditional glaucoma surgery. SUMMARY: A management algorithm is presented based on our practice pattern to help guide decision-making for glaucoma surgeons. Although we encourage surgeons to continue to broaden their toolkit, we emphasize the continued importance of teaching the next-generation traditional glaucoma surgery in the MIGS era. Future prospective studies are warranted to elucidate the optimal treatment strategy for patients with glaucoma.


Asunto(s)
Glaucoma , Presión Intraocular , Procedimientos Quirúrgicos Mínimamente Invasivos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Glaucoma/cirugía , Presión Intraocular/fisiología , Trabeculectomía/métodos , Cirugía Filtrante/métodos , Implantes de Drenaje de Glaucoma
3.
Int Ophthalmol ; 44(1): 317, 2024 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-38972018

RESUMEN

PURPOSE: To evaluate and compare the long-term outcomes of canaloplasty and phaco-canaloplasty in the treatment of open angle glaucoma and assess the prognostic factors associated with surgical outcome. METHODS: A 48-month retrospective analysis was performed on n = 133 open angle glaucoma eyes treated with canaloplasty and n = 57 open angle glaucoma eyes treated with phaco-canaloplasty by a single surgeon. Surgical success was defined according to six criteria, achieving a target intraocular pressure (IOP) ≤ 21, 18 or 15 mmHg on glaucoma medications (qualified success) or without any further treatment (complete success), including laser therapy or surgery. Kaplan-Meier survival analysis and Cox regression analysis were performed to evaluate surgical success and preoperative factors associated with surgical outcome. Surgical complications in the early postoperative period were compared between canaloplasty and phaco-canaloplasty. RESULTS: Canaloplasty and phaco-canaloplasty significantly reduced postoperative IOP and number of glaucoma medications (p = 0.001 for both). Phaco-canaloplasty showed higher rates of cumulative surgical success over canaloplasty, but only for target IOP ≤ 21 and ≤ 18 (p = 0.018 and p = 0.011, respectively). A preoperative number of > 4 glaucoma medications predicted surgical failure. Phaco-canaloplasty was associated with a higher rate of IOP peaks in the first month compared with canaloplasty (40.4% vs 12.7%, p = 0.000). CONCLUSION: Canaloplasty and phaco-canaloplasty demonstrated long-term efficacy in the treatment of open angle glaucoma, with phaco-canaloplasty showing higher rates of surgical success compared to canaloplasty, but not for target IOPs lower than 16 mmHg. Patients on more than 4 preoperative glaucoma medications may not be good candidates for canaloplasty and may benefit from other surgical options.


Asunto(s)
Cirugía Filtrante , Glaucoma de Ángulo Abierto , Presión Intraocular , Humanos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/fisiopatología , Estudios Retrospectivos , Femenino , Masculino , Presión Intraocular/fisiología , Anciano , Persona de Mediana Edad , Cirugía Filtrante/métodos , Estudios de Seguimiento , Resultado del Tratamiento , Agudeza Visual , Facoemulsificación/métodos , Anciano de 80 o más Años , Factores de Tiempo
5.
Int Ophthalmol ; 44(1): 231, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38822988

RESUMEN

PURPOSE: To analyze the intraoperative challenges of cataract surgery in children, following glaucoma filtering surgery. METHODS: This was a retrospective study to analyze intra-op challenges and outcomes of pediatric cataract surgery in post-glaucoma filtration surgery eyes, between January 2007 and December 2019. RESULTS: We included 20 eyes of 16 children. The most common glaucoma surgery performed was trabeculectomy and trabeculotomy (14 eyes). The median age at the time of cataract surgery was 74.5 months. The most common cataract surgery performed was lens aspiration with posterior chamber intraocular lens implantation (LA + PCIOL) (9/20). The most common intraoperative challenge faced was difficulty in capsulorrhexis (ten eyes), followed by extension of primary posterior capsulotomy (six eyes). At the final follow up eight eyes had improvement in visual acuity, five eyes had stable visual acuity and five eyes had a drop in visual acuity. In 12/20 eyes IOL was implanted, nine eyes in-the-bag and three eyes had in ciliary sulcus. None of the IOLs in the bag had decentration of IOL. The median postoperative IOP (p = 0.12) and median number of postoperative AGM (p = 0.13) at 2 years remained stable compared to the preoperative values. The IOP remained well controlled in 4 eyes without anti-glaucoma medications and in 14 eyes with anti-glaucoma medications and none needed additional surgery for IOP control. Two eyes developed retinal detachment postoperatively. CONCLUSION: Cataract surgery in pediatric eyes with prior glaucoma surgeries, have challenges with capsulorrhexis and IOL stability. The visual outcomes were reasonably good so was the IOP control.


Asunto(s)
Extracción de Catarata , Catarata , Glaucoma , Presión Intraocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Extracción de Catarata/métodos , Extracción de Catarata/efectos adversos , Niño , Preescolar , Presión Intraocular/fisiología , Glaucoma/cirugía , Glaucoma/fisiopatología , Catarata/complicaciones , Cirugía Filtrante/métodos , Estudios de Seguimiento , Resultado del Tratamiento , Adolescente , Complicaciones Intraoperatorias , Lactante , Trabeculectomía/métodos , Implantación de Lentes Intraoculares/métodos
6.
Zhonghua Yan Ke Za Zhi ; 60(5): 416-422, 2024 May 11.
Artículo en Chino | MEDLINE | ID: mdl-38706079

RESUMEN

Objective: To investigate the clinical characteristics and treatment outcomes of glaucoma secondary to congenital ectropion uveae (CEU) using penetrating Schlemm's canaloplasty. Methods: This was a retrospective case series study. Medical records of patients diagnosed with glaucoma secondary to CEU and undergoing penetrating Schlemm's canaloplasty at the Eye Hospital of Wenzhou Medical University between August 2020 and December 2021 were collected. Clinical characteristics including the extent and location of iris ectropion, type of glaucoma, were analyzed. Follow-up visits were conducted at 1, 3, 6 months, and 1 year postoperatively. Visual acuity, intraocular pressure (IOP), anterior segment and fundus condition, filtering bleb morphology, use of IOP-lowering medications, ultrasound biomicroscopy results, and other indicators were analyzed to summarize surgical outcomes. Results: Six cases (6 eyes) of glaucoma secondary to CEU were included, all unilateral, with 3 left eyes and 3 right eyes; median age was 10.0 (5.3, 28.8) years; including 3 males and 3 females. Preoperative IOP was (31.7±10.0) mmHg (1 mmHg=0.133 kPa), and the preoperative number of IOP-lowering medications used was 2.0 (2.0, 3.2). The extent of iris ectropion in the 6 cases ranged from 270 ° to 360 °, with peripheral anterior synechiae corresponding to the location of iris ectropion, and angle closure with the degree of synechiae extending beyond Schwalbe's line. No surgical complications occurred in any of the 6 cases postoperatively. At 1 month postoperatively, the IOP was (16.4±3.2) mmHg, with a median of 0.0 (0.0, 1.5) medications used. At 3 months postoperatively, the IOP was (14.8±6.0) mmHg, with a median of 0.0 (0.0, 2.2) medications used. At 6 months postoperatively, the IOP was (18.1±6.1) mmHg, with a median of 0.0 (0.0, 0.5) medications used. Among them, 5 patients had a follow-up period of 1 year postoperatively, all achieving controlled IOP without the use of IOP-lowering medications, with an average IOP of (15.5±3.1) mmHg. No obvious filtering bleb formation was observed at the surgical site in all patients. Conclusions: Glaucoma secondary to CEU manifests primarily as closed-angle glaucoma, with a correspondence between the closure range of anterior iris adhesions in the angle and the extent of iris ectropion. Penetrating Schlemm's canaloplasty demonstrates favorable and stable efficacy for its treatment.


Asunto(s)
Ectropión , Glaucoma , Presión Intraocular , Humanos , Estudios Retrospectivos , Masculino , Femenino , Glaucoma/cirugía , Glaucoma/etiología , Ectropión/etiología , Ectropión/cirugía , Niño , Preescolar , Adulto , Úvea/cirugía , Cirugía Filtrante/métodos , Resultado del Tratamiento , Agudeza Visual , Iris/cirugía , Adulto Joven , Adolescente
7.
Klin Monbl Augenheilkd ; 241(7): 863-880, 2024 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-38788734

RESUMEN

Glaucoma filtration surgery has been a standard surgical therapy for decades. An increasing knowledge about wound healing processes in the eye, the introduction of antimetabolite treatment and continuous improvements of the surgical technique helped making trabeculectomy - the prototype filtration surgery - a very effective therapeutic tool. However, best results will only be regularly achieved with a high level of experience and time dedicated to postoperative follow-up. Furthermore, the potential for severe early and late complications still remains high. Thus, novel stent-based filtration surgery approaches, such as the Preserflo and the XEN shunt have been introduced. This review presents these three bleb-forming filtration procedures, covering the basic principles of surgical technique, data on effectivity as well as complications.


Asunto(s)
Cirugía Filtrante , Implantes de Drenaje de Glaucoma , Glaucoma , Humanos , Glaucoma/cirugía , Cirugía Filtrante/métodos , Trabeculectomía/métodos , Stents
8.
Graefes Arch Clin Exp Ophthalmol ; 262(9): 2845-2850, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38578333

RESUMEN

PURPOSE: This study aimed to evaluate changes in intraocular pressure following intravitreal dexamethasone implant injection, specifically in patients undergoing glaucoma filtration surgery. METHODS: The degree of increase in intraocular pressure was compared retrospectively among three groups. Group 1 comprised patients who underwent prior glaucoma filtration surgery (54 eyes). Group 2 included patients with or suspected glaucoma without such surgical history (20 eyes). Group 3 included patients without glaucoma (33 eyes). Pressure measurements were taken before the injection and at 1, 2, 3, and 6 months post-injection. A subgroup analysis was performed for pressure > 35 mmHg, > 30 mmHg, > 25 mmHg, and a difference > 10 mmHg between the peak and baseline pressure. RESULTS: Group 1 consistently displayed lower pressures compared with Group 2, with significant difference at both 1- and 6-month post-injections (15.09 mmHg vs. 18.10 mmHg, P = 0.042 and 13.91 mg vs. 17.25 mmHg, P = 0.040). The proportion of patients in Group 1 and Group 3 with pressures > 25 mmHg, > 30 mmHg, and a difference > 10 mmHg did not significantly differ (15.6% vs. 9.5%, P = 0.231; 3.1% vs. 2.3%, P = 0.867; and 17.1% vs. 7.1%, P = 0.231). Notably, Group 2 exhibited a significantly higher proportion within each category (> 25 mmHg, 24.0%; > 30 mmHg, 20.0%; > 10 mmHg difference, 28.0%). CONCLUSION: Intravitreal dexamethasone implant did not increase the risk of elevated intraocular pressure in patients with a history of glaucoma filtration surgery compared with patients with suspected glaucoma; the risk was similar to those without glaucoma.


Asunto(s)
Dexametasona , Implantes de Medicamentos , Cirugía Filtrante , Glaucoma , Glucocorticoides , Presión Intraocular , Inyecciones Intravítreas , Humanos , Dexametasona/administración & dosificación , Presión Intraocular/fisiología , Presión Intraocular/efectos de los fármacos , Estudios Retrospectivos , Glucocorticoides/administración & dosificación , Femenino , Masculino , Anciano , Cirugía Filtrante/métodos , Glaucoma/cirugía , Glaucoma/fisiopatología , Estudios de Seguimiento , Persona de Mediana Edad , Tonometría Ocular , Agudeza Visual
9.
J Cataract Refract Surg ; 50(9): 899-905, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38662577

RESUMEN

PURPOSE: To investigate long-term astigmatism after combined nonpenetrating glaucoma surgery (NPGS) and implantation of the first miniaturized suprachoroidal intraocular pressure (IOP) sensor EYEMATE-SC. SETTING: The study was conducted in 5 medical centers in 2 different countries. DESIGN: Retrospective multicenter clinical study. METHODS: Astigmatism of patients instrumented with the EYEMATE-SC IOP sensor was assessed over a follow-up period of 3 years. Refraction and corrected distance visual acuity (CDVA) were obtained preoperatively, after 6 months, 1, 2, and 3 years. A canaloplasty-operated patient cohort served as control. Astigmatism was evaluated using 3-dimensional power vector analysis involving the spherical equivalent M, and the Jackson crossed cylinder projections J 0 and J 45 . Exclusion criteria included neovascular and angle-closure glaucoma, myopia, axial length outside 22 to 26 mm, other ocular diseases, prior glaucoma surgery, other ocular surgery within 6 months (cataract surgery within 3 months) before NPGS, serious generalized conditions, and other active medical head/neck implants. RESULTS: Multivariate analysis indicated no changes in astigmatism along the observation period in both the EYEMATE-SC (n = 24) and the canaloplasty (n = 24) group ( P > .05 or nonsignificant after Bonferroni correction). Astigmatism was unchanged between the EYEMATE-SC and the canaloplasty group at all timepoints ( P > .05). CDVA did not change along the observation period of 3 years in each of both groups ( P > .05). CONCLUSIONS: Despite its suprachoroidal localization, this study indicated that the miniaturized EYEMATE-SC IOP sensor did not negatively affect long-term astigmatism after combined implantation with NPGS.


Asunto(s)
Astigmatismo , Presión Intraocular , Tonometría Ocular , Agudeza Visual , Humanos , Presión Intraocular/fisiología , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Estudios Retrospectivos , Agudeza Visual/fisiología , Masculino , Femenino , Anciano , Persona de Mediana Edad , Estudios de Seguimiento , Glaucoma/cirugía , Glaucoma/fisiopatología , Refracción Ocular/fisiología , Complicaciones Posoperatorias , Implantes de Drenaje de Glaucoma , Anciano de 80 o más Años , Transductores de Presión , Implantación de Prótesis , Cirugía Filtrante/métodos
10.
Graefes Arch Clin Exp Ophthalmol ; 262(9): 2977-2984, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38625448

RESUMEN

PURPOSE: The success of XEN Gel Stent (XEN) and Preserflo MicroShunt (Preserflo) implantation depends mainly on the development of bleb fibrosis. This study aimed to describe the histological findings of bleb fibrosis after XEN and Preserflo surgery. METHODS: This retrospective study included patients with different types of glaucoma who underwent revision surgery after XEN or Preserflo implantation. The available clinical information and histological samples of removed fibrotic tissue were analyzed. RESULTS: Thirty-six patients were included. Revision surgery was performed at a median of 195 (range = 31-1264) days after primary surgery. The mean intraocular pressure changed from 29.1 (± 10.3) mmHg at baseline to 18.3 (± 8.7) mmHg (- 37%; p < 0.0001) and 16.2 (± 4.2) mmHg (- 45%; p < 0.0001) after 6 and 12 months, respectively. Histological analysis revealed an increase in activated fibroblasts and macrophages in all specimens and a parallel orientation of fibroblasts in a minor part of the probe in 60% of the specimens. No pronounced inflammatory reaction in the form of lymphocytic or granulocytic infiltration was observed. The comparison of specimens from uveitic glaucoma and primary open-angle glaucoma patients revealed no significant differences. CONCLUSIONS: The histological analysis of fibrotic blebs from the XEN and Preserflo implants did not show any pronounced immune or foreign-body reaction and revealed a similar histological pattern of failed blebs after trabeculectomy.


Asunto(s)
Implantes de Drenaje de Glaucoma , Presión Intraocular , Stents , Humanos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Implantes de Drenaje de Glaucoma/efectos adversos , Stents/efectos adversos , Presión Intraocular/fisiología , Reoperación , Glaucoma/cirugía , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Fibrosis , Anciano de 80 o más Años , Conjuntiva/patología , Conjuntiva/cirugía , Adulto , Estudios de Seguimiento , Complicaciones Posoperatorias/diagnóstico , Cirugía Filtrante/efectos adversos , Cirugía Filtrante/métodos , Diseño de Prótesis , Vesícula/diagnóstico , Vesícula/cirugía , Vesícula/etiología
11.
Int Ophthalmol ; 44(1): 208, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38683414

RESUMEN

PURPOSE: To present the modified surgery technique of new suture probe canaloplasty with a specially prepared monofilament 4.0 polypropylene suture combined with suprachoroidal drainage (ScD) and collagen sheet implantation for non-penetrating glaucoma surgery. METHODS: Prospective study with a twelve months follow-up. A standard 4/0 polypropylene suture (ProleneTM by Ethicon; thickness: approximately 250 m) is cut and shaped with an ophthalmic knife (MANI® Crescent Knife, Mani Inc 8-3 Kiyohara Industrial Park, Utsunomiya, Tochigi 321-3231, Japan) to create a blunt end without sharp or compressed edges. This improves suture probe canaloplasty by providing a more stable and smoother probing device. Schlemm's canal is prepared using the standard technique of canaloplasty with suprachoroidal drainage. Then, instead of using the canaloplasty microcatheter or the previously published 6/0 double-helix suture, Schlemm's canal is probed with the blunt ending of the 4/0 Prolene suture. After successful 360-degree probing, a doubled 10/0 polypropylene tension suture is threaded through the tip of the 4/0 suture. The 4/0 suture is then pulled back and the 10/0 tension sutures are tied at both ends to tension Schlemm's canal. A special collagen sheet (Ologen®) is placed in suprachoroidal space, and the scleral flap is firmly sewed. RESULTS: 115 eyes were included in this prospective study. In 113 cases the Schlemm's canal could completely be probed with the suture probe and canaloplasty with ScD and collagen sheet implantation succeeded. In two cases the intervention was transformed to 360-degree suture trabeculotomy due to an intraoperative cheese-wiring. Twelve months after successful new suture probe canaloplasty with ScD and Collagen Implantation the IOP had decreased by 37.1% (from 21.6 ± 6.0 mmHg with 3.3 different IOP lowering eye drops to 13.5 ± 3.5 mmHg with 1.0 eye drops). 16 Patients did not achieve sufficient IOP levels and underwent 360-degree suture trabeculotomy during the follow-up. One patient had to be treated with further glaucoma surgery to achieve a sufficient IOP level. Complications were hyphema, postoperative IOP elevation and transient hypotony. No serious or sight-threatening complications occurred. CONCLUSION: New suture probe canaloplasty with ScD and collagen sheet implantation yields the opportunity to conduct a cost-effective canaloplasty easier and less complicated than with the previously described method with the twisted 6/0 suture. The safety profile and IOP lowering effect is comparable. In cases where complete probing fails, there is still the opportunity to switch to suture trabeculotomy over the majorly probed part of Schlemm's canal. The pressure lowering effect of the deep sclerectomy with ScD and suprachoroidal collagen sheet implant seems to have an additional impact on the sufficient pressure lowering procedure.


Asunto(s)
Colágeno , Presión Intraocular , Técnicas de Sutura , Suturas , Humanos , Técnicas de Sutura/instrumentación , Estudios Prospectivos , Presión Intraocular/fisiología , Masculino , Femenino , Polipropilenos , Estudios de Seguimiento , Glaucoma/cirugía , Persona de Mediana Edad , Anciano , Coroides/cirugía , Cirugía Filtrante/métodos
12.
J Ocul Pharmacol Ther ; 40(5): 297-308, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38687355

RESUMEN

Purpose: To investigate gel stent implantation with and without intraoperative sustained-release mitomycin C (MMC SR) in a rabbit model for gel stent implantation, and to examine aqueous humor outflow (AHO) postimplantation. Methods: Four groups of rabbits were included. Group 1 was untreated (control). Groups 2, 3, and 4 received the gel stent without MMC, with MMC solution (subconjunctival injection), and with MMC SR (subconjunctival injection), respectively. Intraocular pressure (IOP) and AHO were assessed via tonometry and indocyanine green-based angiography, respectively. The main efficacy measure was change in IOP from baseline. Results: Following gel stent implantation, Groups 2, 3, and 4 maintained ≥20% IOP reduction (response) for a median duration of 1 week, 6.5 weeks, and 30 weeks, respectively. Angiography showed normal aqueous humor drainage (Group 1) beginning at the perilimbal trabecular plexus and continuing posteriorly to episcleral outflow vessels. Following implantation, drainage occurred preferentially and directly into the subconjunctival bleb. Conclusions: Gel stent implantation with MMC SR was most effective in achieving sustained, long-term IOP reduction in the rabbit model, compared with implantation with or without MMC solution. Bleb presence and the postimplantation aqueous angiography results indicated redirection of the AHO to the subconjunctival vasculature and presumed lymphatics, suggesting efficient glaucoma filtration to lower IOP in this model. This rabbit model and aqueous angiography may help refine understanding of the mechanism of action of minimally invasive glaucoma surgeries and ultimately translate to improved surgical devices and procedures for patients with glaucoma.


Asunto(s)
Humor Acuoso , Preparaciones de Acción Retardada , Cirugía Filtrante , Presión Intraocular , Mitomicina , Animales , Conejos , Mitomicina/administración & dosificación , Mitomicina/farmacología , Cirugía Filtrante/métodos , Presión Intraocular/efectos de los fármacos , Humor Acuoso/metabolismo , Humor Acuoso/efectos de los fármacos , Stents , Geles , Glaucoma/cirugía , Glaucoma/tratamiento farmacológico , Conjuntiva/cirugía , Modelos Animales de Enfermedad
13.
Eur J Ophthalmol ; 34(3): NP87-NP91, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38377952

RESUMEN

PURPOSE: To describe a case of acquired glaucomatous optic disc pit-related maculopathy successfully treated with glaucoma filtering surgery alone. CASE DESCRIPTION: A 67-year-old male was diagnosed with advanced primary open angle glaucoma in both eyes, with a cup: disc ratio of 0.85 in the right eye and 0.95 in the left eye. Visual acuity at presentation was 20/60, and intraocular pressure was 14 mm Hg in the left eye. The fundus of the left eye revealed a serous macular retinal detachment due to an acquired optic disc pit. RESULTS: The left eye of the patient underwent combined cataract and glaucoma filtering surgery. The serous macular detachment resolved completely 15 months after surgery, with a documented visual acuity of 20/40 and intraocular pressure of 10 mm Hg without the use of additional antiglaucoma medications. There was no recurrence of serous macular detachment even after the two-year follow-up visit. CONCLUSION: This case demonstrates that controlling intraocular pressure alone resulted in complete resolution of serous macular detachment in acquired optic disc pit maculopathy without the need for pars plana vitrectomy.


Asunto(s)
Glaucoma de Ángulo Abierto , Presión Intraocular , Disco Óptico , Desprendimiento de Retina , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Masculino , Disco Óptico/anomalías , Anciano , Desprendimiento de Retina/cirugía , Desprendimiento de Retina/diagnóstico , Desprendimiento de Retina/etiología , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/complicaciones , Presión Intraocular/fisiología , Agudeza Visual/fisiología , Angiografía con Fluoresceína , Cirugía Filtrante/métodos , Anomalías del Ojo/complicaciones , Anomalías del Ojo/cirugía
14.
Acta Ophthalmol ; 102(5): e797-e804, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38306110

RESUMEN

PURPOSE: Bleb failure is a common complication after glaucoma filtration surgery. Different bleb classification schemes incorporating filtration bleb vascularization have been proposed, but the reported correlation with intraocular pressure (IOP) has been variable, possibly because of subjective vascularization grading. The purpose of the present study was to evaluate bleb vascularization after Preserflo Microshunt (PM) implantation using anterior segment OCT-angiography (AS-OCTA) as a biomarker for bleb failure. METHODS: Twenty-three eyes of twenty-three patients underwent PM implantation. Up to 12 months after surgery PM scleral passage-centred AS-OCTA measurements (PLEX Elite 9000) for bleb-vessel density (BVD) determination were performed and IOP as well as necessity for surgical revisions (needling and open revision) were documented. After multi-step image analysis (region of interest definition, artefact removal, binarization, BVD calculation), the predictive value of early postoperative BVD for surgical revisions was assessed using logistic regression modelling. RESULTS: Baseline IOP (23.57 ± 7.75 mmHg) decreased significantly to 8.30 ± 2.12, 9.17 ± 2.33 and 11.70 ± 4.40 mmHg after 1, 2 and 4 week(s), and 13.48 ± 5.83, 11.87 ± 4.49, 12.30 ± 6.65, 11.87 ± 3.11 and 13.05 ± 4.12 mmHg after 2, 3, 6, 9 and 12 month(s), respectively (p < 0.001). Nine patients (39%) needed surgical revisions after a median time of 2 months. Bleb vessel densities at 2 and 4 weeks were significantly associated with future surgical revisions upon logistic regression analysis (2 W/4 W likelihood-ratio test p-value: 0.0244/0.0098; 2 W/4 W area under the receiver operating characteristics curve: 0.796/0.909). CONCLUSION: Filtration bleb vessel density can be determined using AS-OCTA in the early postoperative period and is predictive for bleb failure after PM implantation.


Asunto(s)
Presión Intraocular , Reoperación , Tomografía de Coherencia Óptica , Humanos , Femenino , Masculino , Presión Intraocular/fisiología , Anciano , Tomografía de Coherencia Óptica/métodos , Persona de Mediana Edad , Angiografía con Fluoresceína/métodos , Estudios de Seguimiento , Glaucoma/cirugía , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Implantes de Drenaje de Glaucoma/efectos adversos , Cirugía Filtrante/métodos , Estudios Prospectivos , Fondo de Ojo , Conjuntiva/irrigación sanguínea , Conjuntiva/cirugía , Densidad Microvascular
15.
J Pediatr Ophthalmol Strabismus ; 61(3): 188-197, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38112386

RESUMEN

PURPOSE: To describe the clinical characteristics and outcomes of a pediatric cohort surgically treated for primary or secondary pediatric glaucoma (PPG/SPG). METHODS: A retrospective chart review was conducted of all patients with pediatric glaucoma who had surgery between 2013 and 2021. Relevant demographic and clinical data were cumulated and analyzed. RESULTS: Forty-two eyes of 29 patients (18 girls and 11 boys) were included: 22 (52.4%) primary congenital glaucoma (PCG), 7 (16.7%) juvenile open-angle glaucoma, and 13 (30.9%) SPG. Mean ages at presentation were 2.57 ± 2.87, 131.96 ± 27.71, and 62.09 ± 65.12 months, respectively. In this study, eyes with PCG presented the earliest, with the highest intraocular pressure (IOP) and thickest central corneal thickness (CCT). The mean number of glaucoma surgeries was 1.48 ± 0.71, with 38.1% of the eyes needing two or more glaucoma surgeries; trabeculectomy was the most frequent glaucoma surgery in this cohort. After surgical intervention, the overall mean IOP dropped from 32.25 ± 12.97 to 18.10 ± 9.23 mm Hg (P < .001). Moreover, the percentage using antiglaucoma medications decreased from 100% to 35.7% at the final visit, as did the number of medications prescribed per eye (2.69 ± 0.92 vs 1.05 ± 1.46, P ≤ .001). Mean best corrected visual acuity (BCVA), in patients who could have their BCVA measured, improved from 0.61 ± 0.61 to 0.53 ± 0.51 logMAR at final follow-up. CONCLUSIONS: Surgical intervention was shown to provide a well-controlled IOP, decrease dependance on glaucoma medications, and improve BCVA in both PPG and SPG. Multiple surgical interventions may be necessary in the treatment of some pediatric patients with glaucoma. Prognostically, thicker CCT was significantly associated with worse IOP control, more glaucoma surgeries, and more antiglaucoma medications at the final visit. Initial BCVA correlated significantly with BCVA at the final visit. [J Pediatr Ophthalmol Strabismus. 2024;61(3):188-197.].


Asunto(s)
Glaucoma , Hospitales Universitarios , Presión Intraocular , Agudeza Visual , Humanos , Femenino , Masculino , Estudios Retrospectivos , Presión Intraocular/fisiología , Preescolar , Agudeza Visual/fisiología , Niño , Lactante , Glaucoma/cirugía , Glaucoma/fisiopatología , Turquía/epidemiología , Resultado del Tratamiento , Estudios de Seguimiento , Trabeculectomía/métodos , Adolescente , Tonometría Ocular , Cirugía Filtrante/métodos
16.
Asia Pac J Ophthalmol (Phila) ; 12(6): 537-564, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38079242

RESUMEN

The development of minimally invasive glaucoma surgeries (MIGSs) was intended to provide safe and modestly efficacious modalities for early intervention of mild-to-moderate glaucoma, with minimal trauma and rapid recovery. They were mainly ab interno procedures that reduce intraocular pressure by facilitating the aqueous outflow by bypassing the trabecular meshwork resistance, reinforcing the uveoscleral flow via the supraciliary space, and reducing aqueous production by the ciliary body. While the cumulating evidence helps shape the role of the available MIGS, the exponential new development and advancement in this field has expanded the territory of MIGS. Apart from developing subconjunctival MIGS filtration devices (Xen gel stent and PRESERFLO MicroShunt), there is a tendency to revisit the "traditional" MIGS for alternative use and to modify the procedures with consideration of the fundamental aqueous outflow physiology. Combined MIGS has also been suggested, based on the theory that their different mechanisms may provide additive or synergistic effects. The advancement of laser procedures is also promising and could supplement unmet needs along the glaucoma treatment algorithm. This review examines the broad array of MIGS, updates the recent findings, discusses their potential alternative applications, and explores future challenges.


Asunto(s)
Cirugía Filtrante , Implantes de Drenaje de Glaucoma , Glaucoma , Humanos , Glaucoma/cirugía , Presión Intraocular , Cirugía Filtrante/métodos , Tonometría Ocular
17.
J Fr Ophtalmol ; 46(10): 1227-1231, 2023 Dec.
Artículo en Francés | MEDLINE | ID: mdl-37945427

RESUMEN

The surgical management of glaucoma has been enriched in recent years by the arrival of new surgical techniques as a group known as MIGS (minimally invasive glaucoma surgery). The objective of these new techniques is to reduce intraocular pressure (IOP) while limiting the risk of complications of conventional filtering surgery and allowing faster visual recovery. MIGS can be classified into three main categories depending on the route used to promote the outflow of aqueous humor: the trabecular route, the suprachoroidal route and the subconjunctival route. MIGS using the subconjunctival route are also called minimally invasive bleb surgery (MIBS). These new techniques do not replace conventional filtering surgery, which remains the gold standard technique, but now offer new alternatives for the surgical management of glaucoma patients in combination with cataract surgery or as stand-alone procedures.


Asunto(s)
Extracción de Catarata , Cirugía Filtrante , Implantes de Drenaje de Glaucoma , Glaucoma , Humanos , Glaucoma/cirugía , Presión Intraocular , Cirugía Filtrante/métodos , Extracción de Catarata/efectos adversos
18.
Br J Ophthalmol ; 107(8): 1092-1097, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-35318223

RESUMEN

BACKGROUND/AIM: To evaluate the clinical outcomes of penetrating canaloplasty in traumatic angle recession glaucoma at 1 year. METHODS: Patients with angle recession glaucoma underwent penetrating canaloplasty, a new Schlemm's canal-based internal drainage procedure, which creates a direct canal for flow of aqueous humour from the anterior chamber to the ostia of Schlemm's canal via a window created at the corneal scleral bed without use of antimetabolites. Postoperative intraocular pressure (IOP), number of glaucoma medications, and procedure-related complications were evaluated. Success was defined as an IOP ≤21 mm Hg without (complete) or with (qualified) use of glaucoma medication. RESULTS: Forty eyes in 40 patients with angle recession glaucoma underwent successful circumferential catheterisation. The mean patient age was 42±13 years. In patients with penetrating canaloplasty that was deemed to be completely successful, the mean IOP decreased from a preoperative value of 37.8±12.3 mm Hg on 3.3±1.2 anti-glaucoma medications to 18.5±6.4 mm Hg on 1.2±1.4 medications, 14.9±4.6 mm Hg on 0.1±0.5 medications, 15.7±5.4 mm Hg on 0.1±0.4 medications and 14.8±3.6 mm Hg on 0.1±0.5 medications at 1, 3, 6 and 12 months postoperatively (p<0.05). Complete success was achieved in 35/40 eyes (87.5%) at 6 months and in 34/38 (89.5%) at 12 months. Hyphema (18/40, 45.0%) and transient IOP elevation (≥30 mm Hg, 9/40, 22.5%) were the most common postoperative complications. CONCLUSION: Penetrating canaloplasty significantly reduces IOP and has a high success rate in angle recession glaucoma. TRIAL REGISTRATION NUMBER: ChiCTR1900020511.


Asunto(s)
Cirugía Filtrante , Glaucoma de Ángulo Abierto , Glaucoma , Humanos , Adulto , Persona de Mediana Edad , Estudios Prospectivos , Cirugía Filtrante/métodos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma/cirugía , Presión Intraocular , Resultado del Tratamiento
19.
Rom J Ophthalmol ; 66(3): 225-232, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36349177

RESUMEN

The modern glaucoma surgeon is faced with many surgical alternatives for the management of glaucoma. In recent years, numerous techniques that make Schlemm's canal (SC) more accessible for surgery by being less invasive and surgically less challenging were introduced. Since its first introduction, canaloplasty has become a well-established method of glaucoma surgery. The aim of this paper was to present an overview of canaloplasty and its modifications, and to highlight their strong points and potential drawbacks based on available data on the effectiveness of each technique. Furthermore, it offered an overview of the development of canaloplasty over time and the clinical aspects that should be considered in patient selection. Abbreviations: ABiC = Canaloplasty ab interno, AH = aqueous humour, CSD = Canaloplasty with suprachoroidal drainage, IOP = intraocular pressure, MIGS = minimally invasive glaucoma surgery, OAG = open angle glaucoma, PEXG = pseudoexfoliation glaucoma, SC = Schlemm's canal, TDM = trabeculo-Descemet's membrane.


Asunto(s)
Síndrome de Exfoliación , Cirugía Filtrante , Glaucoma de Ángulo Abierto , Glaucoma , Humanos , Glaucoma de Ángulo Abierto/cirugía , Cirugía Filtrante/métodos , Presión Intraocular , Humor Acuoso , Glaucoma/cirugía
20.
Am J Ophthalmol ; 243: 83-90, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35870489

RESUMEN

PURPOSES: To report the efficacy of a bleb-independent penetrating canaloplasty in the management of glaucoma secondary to iridocorneal endothelial syndrome (GS-ICE). DESIGN: Prospective, non-comparative clinical study. METHODS: Penetrating canaloplasty was performed on 35 eyes from 35 patients with GS-ICE and medically uncontrolled intraocular pressure (IOP) between January 2018 and April 2020. Patients were followed up at 1 week, months 1, 3, 6, 12 postoperatively, and semi-annually thereafter. The IOP, anti-glaucoma medication, and surgery-related complications were recorded. Surgical success was defined as IOP ≥ 5 mmHg and ≤ 21 mmHg without (complete success) or with/without (qualified success) IOP-lowering medication. RESULTS: A total of 29 eyes (82.9%) had 360° catheterization and successfully received penetrating canaloplasty. Of these eyes, 24 (82.8%) achieved qualified success and 22 (75.9%) achieved qualified success at 12 months after surgery. The mean IOP decreased from 39.5 ± 11.8 mmHg on 2.9 ± 1.0 medications before surgery to 16.6 ± 5.3 mmHg (P < .001) on 0.2 ± 0.6 medications (P < .001) at 12 months postoperatively, respectively. Hyphema (37.9%), transient hypotony (34.5%), and transient postoperative IOP elevation (≥ 30 mmHg, 17.9%) were the most commonly observed early complications at the 1 week and 1 month visits. From 1 month and beyond, all treated eyes showed no obvious bleb at the operation quadrant. CONCLUSIONS: Penetrating canaloplasty rescued the inner aqueous outflow in ICE eyes and demonstrated acceptable success in IOP control with few complications, providing a new option for the management of GS-ICE.


Asunto(s)
Cirugía Filtrante , Glaucoma de Ángulo Abierto , Glaucoma , Síndrome Endotelial Iridocorneal , Trabeculectomía , Humanos , Agentes Antiglaucoma , Cirugía Filtrante/métodos , Glaucoma/complicaciones , Glaucoma/cirugía , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular , Síndrome Endotelial Iridocorneal/complicaciones , Síndrome Endotelial Iridocorneal/diagnóstico , Síndrome Endotelial Iridocorneal/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Trabeculectomía/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA