Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.171
Filtrar
1.
Methodist Debakey Cardiovasc J ; 20(1): 80-86, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247626

RESUMEN

The WATCHMAN™ atrial appendage closure device is designed to reduce the risk of stroke in patients with nonvalvular atrial fibrillation who are not suitable candidates for long-term oral anticoagulation therapy. However, the device also carries small risks, including procedural complications such as device migration, embolization, or pericardial effusion. We describe a case of WATCHMAN device migration requiring surgical retrieval.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Remoción de Dispositivos , Migración de Cuerpo Extraño , Humanos , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/cirugía , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/terapia , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Resultado del Tratamiento , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Masculino , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Femenino , Anciano , Ecocardiografía Transesofágica , Diseño de Prótesis
3.
JACC Cardiovasc Interv ; 17(17): 1963-1979, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39260958

RESUMEN

Intravascular ultrasound and optical coherence tomography are used with increasing frequency for the care of coronary patients and in research studies. These imaging tools can identify culprit lesions in acute coronary syndromes, assess coronary stenosis severity, guide percutaneous coronary intervention (PCI), and detect vulnerable plaques and patients. However, they have significant limitations that have stimulated the development of multimodality intracoronary imaging catheters, which provide improvements in assessing vessel wall pathology and guiding PCI. Prototypes combining 2 or even 3 imaging probes with complementary attributes have been developed, and several multimodality systems have already been used in patients, with near-infrared spectroscopy intravascular ultrasound-based studies showing promising results for the identification of high-risk plaques. Moreover, postmortem histology studies have documented that hybrid imaging catheters can enable more accurate characterization of plaque morphology than standalone imaging. This review describes the evolution in the field of hybrid intracoronary imaging; presents the available multimodality catheters; and discusses their potential role in PCI guidance, vulnerable plaque detection, and the assessment of endovascular devices and emerging pharmacotherapies targeting atherosclerosis.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Imagen Multimodal , Intervención Coronaria Percutánea , Placa Aterosclerótica , Valor Predictivo de las Pruebas , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Intervención Coronaria Percutánea/instrumentación , Diseño de Equipo , Catéteres Cardíacos , Difusión de Innovaciones , Cateterismo Cardíaco/instrumentación , Espectroscopía Infrarroja Corta , Animales
12.
JACC Cardiovasc Interv ; 17(16): 1936-1945, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39197992

RESUMEN

BACKGROUND: Data on procedural and early outcomes after transjugular transcatheter tricuspid valve replacement (TTVR) are limited. OBJECTIVES: This study sought to evaluate first-in-man procedural and clinical outcomes after transjugular TTVR with a special focus on patients who received large device sizes in whom TTVR outcomes have been questioned. METHODS: The retrospective registry included patients who underwent TTVR using the LuX-Valve Plus system (Jenscare Biotechnology Co Ltd) for symptomatic tricuspid regurgitation (TR) from January 2022 until February 2024 at 15 international centers in a compassionate use setting. The endpoints were procedural TR reduction, in-hospital death, adverse events, and 1-month survival. We further stratified results according to the size of the implanted device (<55 vs ≥55 mm). RESULTS: The registry included a total of 76 patients at a median age of 78 years (Q1-Q3: 72-83 years, 47.4% women). TR was reduced to ≤2+ and ≤1+ in 94.7% and 90.8% of patients (75.0% of patients received TTVR devices ≥55 mm) with well-sustained results at 1-month follow-up (TR ≤2+ in 95.0% and ≤1+ 86.8%). Residual TR was paravalvular in all cases. In-hospital death occurred in 4 patients (5.3%). Four patients (5.3%) underwent cardiac surgery during index hospitalization. Major in-hospital bleeding events occurred in 5 patients (6.6%). New in-hospital pacemaker implantation was required in 3.9% of patients in the overall cohort (5.7% in "pacemaker-naive" individuals). No cases of valve thrombosis, stroke, myocardial infarction, or pulmonary embolism were observed. At 1-month follow-up, survival was 94.4%, and NYHA functional class significantly improved. One further patient received a pacemaker, 1 further bleeding event occurred, and 2 patients underwent reintervention or surgery within the first 30 days after TTVR. No differences in procedural outcomes or adverse events were observed after stratification for valve size. CONCLUSIONS: Transjugular TTVR appears to be a safe and effective treatment option for patients with severe TR with comparable outcomes in very large tricuspid anatomies.


Asunto(s)
Cateterismo Cardíaco , Ensayos de Uso Compasivo , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Femenino , Masculino , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Factores de Tiempo , Anciano de 80 o más Años , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Factores de Riesgo , Mortalidad Hospitalaria , Complicaciones Posoperatorias/etiología , Venas Yugulares
14.
JACC Cardiovasc Interv ; 17(16): 1905-1915, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39197989

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is associated with worse clinical outcomes after transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (M-TEER), but little is known about its association with health status outcomes. OBJECTIVES: The aims of this study were to explore, using the Society of Thoracic Surgeons and American College of Cardiology TVT (Transcatheter Valve Therapy) Registry, the association between baseline TR and health status after TAVR and M-TEER and to determine if baseline TR was associated with clinical endpoints. METHODS: Health status was assessed using Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS) score in patients enrolled in the TVT Registry who underwent isolated TAVR or M-TEER between January 2019 and June 2021. The association among baseline TR and KCCQ-OS score, being alive and well, and clinical outcomes was examined. RESULTS: In total, 130,097 TAVR patients (13.1% with moderate TR, 2.3% with severe TR) and 19,593 M-TEER patients (33.2% with moderate TR, 14.7% with severe TR) were included. Mean KCCQ-OS scores were lower with severe vs moderate vs none to mild TR at baseline prior to TAVR (39.4 ± 24.2 vs 45.2 ± 24.7 vs 51.3 ± 25.3; P < 0.01) or M-TEER (38.1 ± 23.9 vs 41.9 ± 24.7 vs 45.4 ± 25.2; P < 0.01) and similarly at 30 days and 1 year. The odds of being alive and well at 1 year were lower with moderate or severe TR before TAVR (adjusted OR: 0.79 [95% CI: 0.74-0.85] and adjusted OR: 0.81 [95% CI: 0.70-0.94], respectively) and severe TR before M-TEER (adjusted OR: 0.53; 95% CI: 0.40-0.71). Furthermore, moderate or severe TR before TAVR was associated with higher 1-year mortality and readmission, whereas moderate or severe TR before M-TEER was associated with higher 1-year mortality. CONCLUSIONS: In a large cohort of U.S. patients who underwent TAVR or M-TEER, greater baseline TR was associated with worse health status and clinical outcomes. Understanding adverse outcomes of TR in patients with coexisting valvular abnormalities is important, especially with rapidly evolving transcatheter tricuspid valve interventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estado de Salud , Válvula Mitral , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Femenino , Masculino , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Estados Unidos , Medición de Riesgo , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Índice de Severidad de la Enfermedad , Recuperación de la Función , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad
15.
Methodist Debakey Cardiovasc J ; 20(1): 65-69, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39157298

RESUMEN

A 76-year-old female with a complicated medical history presented for Watchman (Boston Scientific) placement 2 months after mitral valve transcatheter edge-to-edge repair (TEER). Preoperative workup before Watchman placement confirmed the presence of a thrombus in the left superior pulmonary vein. Post-procedure mitral valve TEER transesophageal echocardiogram showed no thrombus in the left atrium appendage or pulmonary veins. We believe the thrombus in the left superior pulmonary vein occurred secondarily due to epithelium damage during the mitral valve TEER.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Venas Pulmonares , Trombosis de la Vena , Humanos , Femenino , Anciano , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Resultado del Tratamiento , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología , Trombosis de la Vena/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen
16.
BMC Cardiovasc Disord ; 24(1): 439, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39179989

RESUMEN

BACKGROUND: The objective of this study is to investigate the incidence, potential risk factors, and clinical outcomes of incomplete device endothelialization (IDE) in atrial fibrillation (AF) patients undergoing Watchman left atrial appendage closure (LAAC). METHODS: In this study, 68 AF patients who underwent successful implantation of the Watchman device without peri-device leak (PDL) during follow-up were included. The endothelialization status was assessed using Transesophageal echocardiography (TEE) and LAA computed tomography angiography (CTA) at 6 weeks and 6 months post-implantation. Adverse cerebro-cardiac events were documented at one-year follow-up. Baseline characteristics, including age, device sizes, and clinical indicators, were analyzed as potential predictors for IDE. RESULTS: IDE was observed in 70.6% and 67.6% of patients at 6 weeks and 6 months after implantation, respectively. Higher levels of high-density lipoprotein cholesterol (HDL-C) [odds ratio (OR): 15.109, 95% confidence interval (CI): 1.637-139.478, p = 0.017 and OR: 11.015, 95% CI: 1.365-88.896, p = 0.024] and lower aspartate aminotransferase (AST) (OR 0.924, 95% CI: 0.865-0.986, p = 0.017 and OR: 0.930, 95% CI: 0.874-0.990, p = 0.023) at baseline were found to be significantly associated with IDE at 6 weeks and 6 months, respectively, although no significant difference in adverse cerebro-cardiac events was noted between incomplete and complete DE groups during 1-year follow-up CONCLUSIONS: IDE is found to be a prevalent occurrence in humans following LAAC. Elevated HDL-C and reduced AST levels are shown to be linked to an increased risk of IDE after LAAC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Masculino , Femenino , Anciano , Factores de Riesgo , Incidencia , Persona de Mediana Edad , Resultado del Tratamiento , Factores de Tiempo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Angiografía por Tomografía Computarizada , Medición de Riesgo , Anciano de 80 o más Años , Cierre del Apéndice Auricular Izquierdo
18.
EuroIntervention ; 20(16): 972-986, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39155752

RESUMEN

Percutaneous transcatheter structural heart interventions have considerably expanded within the last two decades, improving clinical outcomes and quality of life versus guideline-directed medical therapy for patients frequently ineligible for surgical treatment. Transcatheter structural heart interventions comprise valve implantation or repair and also occlusions of the patent foramen ovale, atrial septal defects and left atrial appendage. These procedures expose structural devices to arterial or venous blood flow with various rheological conditions leading to potential thrombotic complications and embolisation. Furthermore, these procedures may concern comorbid patients at high risk of both ischaemic and bleeding complications. This state-of-the-art review provides a description of the device-related thrombotic risk associated with these transcatheter structural heart interventions and of the current evidence-based guidelines regarding antithrombotic treatments. Gaps in evidence for each of the studied transcatheter interventions and the main ongoing trials are also summarised.


Asunto(s)
Cateterismo Cardíaco , Fibrinolíticos , Humanos , Fibrinolíticos/uso terapéutico , Fibrinolíticos/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Trombosis/prevención & control , Trombosis/etiología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA