Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 216
Filtrar
1.
Vet Res Commun ; 48(6): 4129-4132, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39276269

RESUMEN

Platelet concentrates undergo progressive changes during storage, such as a decrease in pH. Additionally, pH and lactate production showed the strongest correlation with platelet survival in posttransfusion viability studies. pH measurement is a straightforward method for evaluating the quality control of blood components in blood bank practice. Our aim was to compare three pH assessment methods for canine platelet concentrates. The pH values of the canine platelet concentrates were assessed on the first day of storage using a calibrated pH meter, a portable gas analyzer and pH-indicator strips. The results from the pH meter and portable gas analyzer measurements were similar. The pH indicator strips presented higher average values compared to the other more reliable methods evaluated, which could result in the use of inadequate blood components. In conclusion, it is recommended to implement pH measurements using a pH meter for quality control in veterinary blood banks.


Asunto(s)
Bancos de Sangre , Plaquetas , Control de Calidad , Concentración de Iones de Hidrógeno , Animales , Perros/sangre , Plaquetas/química , Plaquetas/fisiología , Bancos de Sangre/normas , Conservación de la Sangre/veterinaria , Conservación de la Sangre/métodos , Conservación de la Sangre/normas
2.
Medwave ; 24(5): e2776, jun. 2024. tab
Artículo en Inglés | LILACS | ID: biblio-1570233

RESUMEN

INTRODUCTION: Platelet concentrates are blood products obtained from donor's blood, and their conservation must be subject to a strict quality control process to guarantee a safe and high-performance product in treating diseases that require their use. METHODS: We designed a cross-sectional study to determine the total compliance rate in platelet concentrates obtained in the blood bank of the Cayetano Heredia Hospital in Lima during November and December of 2019. The Buffy method Coat obtained the platelet concentrates, and parameters such as platelet count and residual leukocytes, pH, and swirling effect were evaluated according to the National Hemotherapy and Blood Bank Program criteria. RESULTS: The platelet count had a mean of 6.66 ± 3.94 x 10¹°/µL, the platelet concentrates had a mean of 56.30 ± 6.22 mL, and all, without exception, had the presence of the Swirling phenomenon. The pH had a mean of 7.64 ± 0.15, while the leukocyte count had a mean of 4.22 ± 3.51 x 107/µL. Regarding compliance by the parameters evaluated, it was evident that the platelet and leukocyte count had moderate compliance rates of 43.6% and 24.1%, while the pH and swirling effect had rates of 100% in both cases. The total compliance rate was 54.9% (95% confidence interval: 46.0 to 63.5). CONCLUSIONS: The compliance rate of platelet concentrates is moderate, and it is necessary to implement a process of continuous quality improvement in the blood bank.


INTRODUCCIÓN: Los concentrados plaquetarios son hemoderivados obtenidos de la sangre, y su conservación debe estar supeditada a un estricto proceso de control de calidad para garantizar un producto inocuo y de alto rendimiento en el tratamiento de enfermedades que requieran su uso. MÉTODOS: Diseñamos un estudio transversal que tuvo por objetivo determinar la tasa de conformidad total en concentrados plaquetarios obtenidos en el banco de sangre del Hospital Cayetano Heredia de Lima durante los meses de noviembre y diciembre del año 2019. Los concentrados plaquetarios fueron obtenidos por el método de Buffy Coat y se evaluaron parámetros como el recuento de plaquetas y leucocitos residuales, pH y efecto swirling, según criterios del Programa Nacional de Hemoterapia y Bancos de Sangre. RESULTADOS: El recuento de plaquetas tuvo una media de 6.66 ± 3.94 x1010/µL y los concentrados plaquetarios tuvieron una media de 56.30 ± 6.22 mL, y todos sin excepción tuvieron presencia de fenómeno Swirling. El pH tuvo una media de 7.64 ± 0.15, mientras que el recuento de leucocitos tuvo una media de 4.22 ± 3.51 x107/µL. En cuanto al cumplimiento por parámetro evaluado, se evidenció que el recuento de plaquetas y leucocitos tuvieron tasas de conformidad de 43.6% y 24.1%, mientras que el pH y efecto swirling tuvieron tasas del 100% en ambos casos. La tasa de conformidad total fue 54.9% (CI95%: 46.0 a 63.5). CONCLUSIONES: La tasa de conformidad de los concentrados plaquetarios es moderada, y se requiere implementar un proceso de mejora continua de la calidad en el banco de sangre.


Asunto(s)
Humanos , Control de Calidad , Bancos de Sangre/normas , Plaquetas , Perú , Recuento de Plaquetas , Estudios Transversales , Transfusión de Plaquetas/métodos , Transfusión de Plaquetas/normas , Hospitales , Concentración de Iones de Hidrógeno , Recuento de Leucocitos
3.
Medwave ; 24(5): e2776, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38905587

RESUMEN

Introduction: Platelet concentrates are blood products obtained from donor's blood, and their conservation must be subject to a strict quality control process to guarantee a safe and high-performance product in treating diseases that require their use. Methods: We designed a cross-sectional study to determine the total compliance rate in platelet concentrates obtained in the blood bank of the Cayetano Heredia Hospital in Lima during November and December of 2019. The Buffy method Coat obtained the platelet concentrates, and parameters such as platelet count and residual leukocytes, pH, and swirling effect were evaluated according to the National Hemotherapy and Blood Bank Program criteria. Results: The platelet count had a mean of 6.66 ± 3.94 x 10¹°/µL, the platelet concentrates had a mean of 56.30 ± 6.22 mL, and all, without exception, had the presence of the Swirling phenomenon. The pH had a mean of 7.64 ± 0.15, while the leukocyte count had a mean of 4.22 ± 3.51 x 107/µL. Regarding compliance by the parameters evaluated, it was evident that the platelet and leukocyte count had moderate compliance rates of 43.6% and 24.1%, while the pH and swirling effect had rates of 100% in both cases. The total compliance rate was 54.9% (95% confidence interval: 46.0 to 63.5). Conclusions: The compliance rate of platelet concentrates is moderate, and it is necessary to implement a process of continuous quality improvement in the blood bank.


Introducción: Los concentrados plaquetarios son hemoderivados obtenidos de la sangre, y su conservación debe estar supeditada a un estricto proceso de control de calidad para garantizar un producto inocuo y de alto rendimiento en el tratamiento de enfermedades que requieran su uso. Métodos: Diseñamos un estudio transversal que tuvo por objetivo determinar la tasa de conformidad total en concentrados plaquetarios obtenidos en el banco de sangre del Hospital Cayetano Heredia de Lima durante los meses de noviembre y diciembre del año 2019. Los concentrados plaquetarios fueron obtenidos por el método de Buffy Coat y se evaluaron parámetros como el recuento de plaquetas y leucocitos residuales, pH y efecto swirling, según criterios del Programa Nacional de Hemoterapia y Bancos de Sangre. Resultados: El recuento de plaquetas tuvo una media de 6.66 ± 3.94 x1010/µL y los concentrados plaquetarios tuvieron una media de 56.30 ± 6.22 mL, y todos sin excepción tuvieron presencia de fenómeno Swirling. El pH tuvo una media de 7.64 ± 0.15, mientras que el recuento de leucocitos tuvo una media de 4.22 ± 3.51 x107/µL. En cuanto al cumplimiento por parámetro evaluado, se evidenció que el recuento de plaquetas y leucocitos tuvieron tasas de conformidad de 43.6% y 24.1%, mientras que el pH y efecto swirling tuvieron tasas del 100% en ambos casos. La tasa de conformidad total fue 54.9% (CI95%: 46.0 a 63.5). Conclusiones: La tasa de conformidad de los concentrados plaquetarios es moderada, y se requiere implementar un proceso de mejora continua de la calidad en el banco de sangre.


Asunto(s)
Bancos de Sangre , Plaquetas , Control de Calidad , Humanos , Perú , Estudios Transversales , Recuento de Plaquetas , Bancos de Sangre/normas , Recuento de Leucocitos , Hospitales , Concentración de Iones de Hidrógeno , Transfusión de Plaquetas/normas , Transfusión de Plaquetas/métodos
4.
DST j. bras. doenças sex. transm ; 35: e23351388, jan. 31, 2023. tab
Artículo en Inglés | LILACS | ID: biblio-1511902

RESUMEN

Introduction: Sexually transmitted infections (STIs) are a serious public health problem, and some of these infections are also transmitted through blood transfusions. Objective: To identify publications in scientific journals in Brazil and in the world showing if there is an important association between serological inadequacy due to sexually transmitted infections traced in blood and blood products used for medical use. Methods: Systematic review of articles published from 2018 to 2023, using the LILACS, SciELO and PubMed databases, with a concomitant approach to the issues of serological disability and STI. Original studies or review articles in Portuguese, English and Spanish with Brazilian and international data were included. Editorial publications, letter to the editor, letter from the editor or comments on the subject were excluded. Results: The search found 571 articles, of which 106 (18.40%) met the inclusion criteria, that is, Serological disability and STI. In studies with international data, the prevalence of donors with hepatitis C ranged from 0.12 to 4.8%; with hepatitis B, from 1.3 to 8.2%; with HIV, from 0.0021 to 2.5%; with syphilis, from 1.73 to 2.4%; with HTLV, 0.66%; and with Chagas disease, from 0.017 to 2.76%. Among articles with Brazilian data, the prevalence of donors with seroreactive tests for hepatitis C ranged from 0.18 to 1.76%; with hepatitis B, from 0.05 to 7.9%; with HIV, from 0.03 to 0.82%; with syphilis, from 0.37 to 3.51%; with HTLV, from 0.02 to 0.3%, and with Chagas disease, from 0.8 to 0.5%. Conclusion: STIs are rarely discussed in the scientific literature in studies on serological inadequacy. In addition, a minority of articles were with Brazilian data. However, results show that STIs, despite being little discussed in the scientific literature in studies on the subject of serological inadequacy, have statistically significant percentages of seropositivity for STIs. Moreover, hepatitis C and B have a relevant seroprevalence, reaching 8.2% and 4.8%, respectively, in the international scenario. In Brazil, hepatitis B continues to occupy a prominent place with a seroprevalence of up to 7.9%. However, syphilis now holds a very important role, with a maximum percentage of 3.51%. More studies are needed for further reflection: although STIs are little addressed in studies about serological inadequacy in human blood banks, would they contribute to the maintenance and non-reduction of the general frequency of infections transmitted by blood transfusion


Introdução: As infecções sexualmente transmissíveis (IST) são um grave problema de saúde pública e algumas dessas infecções, também, transmitidas por intermédio de transfusões de sangue. Objetivo: Identificar publicações em periódicos científicos no Brasil e no mundo sobre se existe importante associação entre inaptidão sorológica por infecções sexualmente transmissíveis rastreadas em sangue e hemoderivados usados para uso médico. Métodos:Revisão sistemática de artigos publicados no período de 2018 a 2023, usando as bases de dados Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs), Scientific Electronic Library Online (SciELO) e United States National Library of Medicine (PubMed) com abordagem concomitante para os assuntos de inaptidão sorológica e IST. Incluíram-se estudos originais ou artigos de revisão nos idiomas português, inglês e espanhol com dados brasileiros e internacionais. Foram excluídas publicações do tipo editorial, carta ao editor, carta do editor ou comentários sobre o tema. Resultados:A busca localizou 571 artigos dos quais 106 (18,40%) se encaixavam nos critérios de inclusão, ou seja, inaptidão sorológica e IST. Em estudos com dados internacionais, a prevalência de doadores com hepatite C variou de 0,12 a 4,8%; com hepatite B de 1,3 a 8,2%; com HIV de 0,0021 a 2,5%; com sífilis de 1,73 a 2,4%; com HTLV 0,66%; e com doença de Chagas de 0,017 a 2,76 %. Já entre os artigos com dados brasileiros, a prevalência de doadores com exames soro-reatores para hepatite C variou de 0,18 a 1,76%; com hepatite B de 0,05 a 7,9%; com HIV de 0,03 a 0,82%; com sífilis de 0,37 a 3,51%; com HTLV 0,02 a 0,3%, e com doença de Chagas de 0,8 a 0,5%. Conclusão: As IST são pouco abordadas na literatura científica em estudos com o tema inaptidão sorológica. Além disso, uma minoria de artigos era com dados brasileiros. Entretanto, resultados demonstram que, apesar de pouco abordadas na literatura científica em estudos com o tema inaptidão sorológica, as IST possuem percentuais de soropositividade estatisticamente significativos. Além disso, as hepatites C e B possuem soroprevalência relevante, podendo chegar a 8,2 e 4,8%, respectivamente, no cenário internacional. Já no cenário nacional, brasileiro, a hepatite B continua ocupando um lugar de destaque, com soroprevalência de até 7,9%. Todavia, a sífilis passa a ocupar um papel de altíssima relevância, com percentual máximo de 3,51%. São necessários mais estudos para mais reflexão: apesar de as IST serem pouco abordadas em estudos acerca da inaptidão sorológica em bancos de sangue humano, seriam elas contribuintes para a manutenção e a não redução da frequência geral de infecções transmitidas por transfusão sanguínea?


Asunto(s)
Bancos de Sangre/normas , Transfusión Sanguínea , Enfermedades de Transmisión Sexual/prevención & control , Enfermedades de Transmisión Sexual/transmisión
7.
Lima; INEN; feb. 2021.
No convencional en Español | BRISA/RedTESA | ID: biblio-1282635

RESUMEN

INTRODUCIÓN: Los pacientes con diagnóstico de neoplasias onco-hematológicas son una población que amerita una gran cantidad de transfusiones de hemocomponentes. El fraccionamiento semi-automatizado es una forma de obtención de hemocomponentes utilizado en muchas unidades de banco de sangre en nuestro país. Sin embargo, cuenta con limitaciones que dificultan una obtención rápida, la calidad de los hemocomponentes y la estandarización de procesos de fraccionamiento. El fraccionamiento automatizado ha surgido como una alternativa del procesamiento de hemocomponentes con múltiples beneficios. ESTRATEGIA DE BÚSQUEDA DE INFORMACIÓN: a) Pregunta Clínica: En los pacientes con diagnóstico oncológico del INEN que tienen indicación para transfusión de hemocomponentes, ¿Cuál es el beneficio del fraccionamiento automatizado de hemocomponentes con filtro leucorreductor comparado con el fraccionamiento semi-automatizado de hemocomponentes? b) RECOLECCIÒN DE LOS MANUSCRITOS A REVISAR: Tipos de estudios: La estrategia de búsqueda sistemática de información científica para el desarrollo del presente informe se realizó siguiendo las recomendaciones de la Pirámide jerárquica de la evidencia propuesta por Haynes y se consideró los siguientes estudios: Sumarios y guías de práctica clínica. Revisiones sistemáticas y/o meta-análisis. Ensayos Controlados Aleatorizados (ECA). Estudios Observacionales (cohortes, caso y control, descriptivos) No hubo limitaciones acerca de la fecha de publicación o el idioma para ningún estudio. DISCUSION: Los pacientes con neoplasias hematológicas suelen presentar disminución espontánea de las constantes corpusculares de forma moderada-severa. Los pacientes con neoplasias sólidas que reciben tratamiento con quimioterapia suelen presentar eventos adversos. Entre los más frecuentes bicitopenias y pancitopenias que ameritan muchas veces múltiples transfusiones de hemocomponentes y que incluso acuden a los servicios de emergencias para transfusión de hemocomponentes. La automatización del proceso de fraccionamiento permite la homogenización de los procedimientos del fraccionamiento. Permite disminuir la variable "error humano", permite mejor la calidad interna de las muestras y disminuir la cantidad de muestras desechadas. Recalcamos particularmente el menor tiempo en que demora el fraccionamiento automatizado, recordando que un buen porcentaje de pacientes amerita transfusión de hemocomponentes de forma rápida por alto riesgo de mortalidad y que el método automatizado genera hemocomponentes de forma más rápidas. La aplicación del fraccionamiento automatizado permitiría realizar la leucoreducción en banco de sangre, lo cual nos ofrece múltiples ventajas. Los estudios descritos encontraron que los métodos de fraccionamiento automatizados necesitaron menor tiempo del procesamiento y presentaron una mayor eficacia en comparación con la leucoreducción fuera del banco de sangre. La leucoreducción disminuye el riesgo de reacciones transfusionales. CONCLUSIONES: 1. Con la aplicación del fraccionamiento automatizado REVEOS obtenemos: homogeneidad de procedimientos, menor tiempo de fraccionamiento, disminuimos variable "Error Humano", optimizamos leucoreducción, mejoramos calidad de hemocomponentes y la disminuimos la eliminación de hemocomponentes. 2. La aplicación del fraccionamiento automatizado beneficiaria de múltiples formas el proceso de transfusión que es tan frecuente en la población oncológica.


Asunto(s)
Humanos , Bancos de Sangre/normas , Transfusión Sanguínea/normas , Buenas Prácticas de Manipulación , Neoplasias/terapia , Evaluación de la Tecnología Biomédica , Evaluación en Salud
8.
BMC Vet Res ; 16(1): 25, 2020 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-32000762

RESUMEN

BACKGROUND: Platelets undergo structural, biochemical and functional alterations when stored, and platelet storage lesions reduce platelet function and half-life after transfusion. The objective of this study was to evaluate stored canine platelet concentrates with platelet aggregation, flow cytometry and biochemistry assays. Twenty-two bags of canine platelet concentrates were obtained by the platelet-rich plasma method and were assessed on days 1, 3 and 5 after collection. Parameters such as platelet counts, residual leukocytes, platelet swirling, glucose, lactate, pH, CD62P expression (platelet activation), JC-1 (mitochondrial function) and annexin V (apoptosis and cell death) were assessed. RESULTS: Over the five days of storage there was a significant decrease in glucose, HCO3, pCO2, ATP, pH, swirling and mitochondrial function, associated with a significant increase in lactate levels and pO2. At the end of storage pH was 5.9 ± 0.6 and lactate levels were 2.8 ± 1.2 mmol/L. Results of the quality parameters evaluated were similar to those reported in human platelets studies. The deleterious effects of storage were more pronounced in bags with higher platelet counts (> 7.49 × 1010/unit), suggesting that canine platelet concentrates should not contain an excessive number of platelets. CONCLUSIONS: Quality parameters of canine platelets under standard storage conditions were similar to those observed in human platelets. Our results have potential to be used for the routine evaluation and quality control in veterinary blood banks.


Asunto(s)
Bancos de Sangre/normas , Plaquetas/fisiología , Conservación de la Sangre/veterinaria , Perros/sangre , Animales , Plaquetas/metabolismo , Activación Plaquetaria , Agregación Plaquetaria , Pruebas de Función Plaquetaria/veterinaria , Control de Calidad
9.
Vox Sang ; 114(8): 808-815, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31625182

RESUMEN

BACKGROUND AND OBJECTIVES: Smokers currently have no defined restrictions for blood donation. However, cigarette smoke contains toxic substances such as carbon monoxide (CO) and trace elements that can affect the packed red blood cells (PRBCs) quality and safety of transfusion. This study evaluated the effects of smoking on the concentration of essential and trace elements and on carboxyhemoglobin (COHb) levels in PRBCs from smoker donors. MATERIALS AND METHODS: A matched case-control study was conducted to compare COHb levels, determined by the CO-oximetry method, and levels of trace (Cd, Pb, Cr, Ni, As and Hg) and essential (Ca, Mg, Cu, Fe, Mn, Mo, Se and Zn) elements evaluated by inductively coupled plasma mass spectrometry, in PRBCs from smoker (n = 36) and non-smoker (n = 36) donors at Hospital de Clínicas de Porto Alegre, Brazil. RESULTS: Mean COHb level was 14 times higher in the PRBCs obtained from smoker donors (5·9 [4·0-9·1] vs. 0·4 [0·2-0·8]%). Cadmium (1·0 [1·0-1·8] µg/l vs. undetectable) and lead (27 [21-36] vs. 19 [14-26] µg/l) levels were significantly higher in the PRBCs from smokers. Moreover, except for molybdenum, levels of all essential elements were lower in smoker PRBCs. CONCLUSION: The PRBCs donated by smokers contain toxic elements that are probably not safe for transfusion in children. Our results might support changes in the current guidelines of blood banks to improve the transfusion safety through inclusion of inquiry about smoking in the clinical screening, labelling and reserve PRBCs from smoker donors for adults or less critical recipients.


Asunto(s)
Donantes de Sangre/estadística & datos numéricos , Fumadores/estadística & datos numéricos , Fumar/sangre , Oligoelementos/sangre , Reacción a la Transfusión/epidemiología , Adulto , Bancos de Sangre/normas , Estudios de Casos y Controles , Eritrocitos/química , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fumar/epidemiología
10.
Biomedica ; 39(s1): 163-171, 2019 05 01.
Artículo en Inglés, Español | MEDLINE | ID: mdl-31529858

RESUMEN

Introduction: Syphilis is a public health concern given its high impact on morbidity and mortality. Objective: We aimed to determine the association of syphilis seroreactivity and seroprevalence with sociodemographic variables of donors at a blood bank in the district of Barranquilla, Colombia, during 2015 and 2016. Materials and methods: We conducted a descriptive cross-sectional study based on the results of the treponemal and nontreponemal tests and the sociodemographic variables of the study population. We performed a univariate analysis to determine the absolute and relative frequencies for each categorical variable. We determined the seroreactivity against Treponema pallidum and the prevalence of active syphilis infection, and we used Pearson's chi-square test to evaluate the differences between the proportions. Results: We found a seroreactivity of 1.86% in individuals with previous T. pallidum infection, and a prevalence of 0.93% in those with active T. pallidum infection. These values were higher in adult men and older adults, widowers, the unemployed, and people living in municipalities of the Department of Atlántico other than Barranquilla and its metropolitan area. The incidence of syphilis infection showed a significant association with sex and occupation. Conclusion: In comparison to the national average, syphilis seroreactivity was high among blood donors. There was an association between syphilis infection incidence and sociodemographic variables such as sex and occupation.


Introducción. La sífilis es una enfermedad de interés en salud pública por sus elevadas tasas de morbilidad y mortalidad. Objetivo. Determinar la serorreacción y la seroprevalencia de sífilis según las variables sociodemográficas de los donantes de un banco de sangre del distrito de Barranquilla, Colombia, durante 2015 y 2016. Materiales y métodos. Se hizo un estudio descriptivo de corte transversal basado en los resultados de las pruebas treponémicas y no treponémicas. Se analizaron las variables sociodemográficas de la población estudiada y se hizo un análisis univariado en el que se determinaron las frecuencias absoluta y relativa de cada una de las variables categóricas. Se determinó la serorreacción a Treponema pallidum y la prevalencia de la infección activa. Se utilizó la prueba de ji al cuadrado de Pearson para evaluar las diferencias entre las proporciones. Resultados. Se encontró una serorreacción de 1,86 % para la infección previa con T. pallidum y una prevalencia de 0,93 % para la infección activa, las cuales fueron más altas en hombres adultos y en adultos mayores, viudos, desempleados y personas residentes en otros municipios del departamento de Atlántico diferentes de Barranquilla y su área metropolitana. Se encontró una asociación significativa entre la sífilis y las variables de sexo y ocupación. Conclusión. Se registró una serorreacción elevada a T. pallidum en donantes de sangre, comparada con el promedio nacional. Se encontró asociación entre la sífilis, y las variables sociodemográficas de sexo y ocupación, principalmente.


Asunto(s)
Bancos de Sangre , Donantes de Sangre , Sífilis/epidemiología , Adolescente , Adulto , Anciano , Anticuerpos Antibacterianos/sangre , Anticuerpos Antibacterianos/inmunología , Bancos de Sangre/normas , Niño , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Seroepidemiológicos , Determinantes Sociales de la Salud , Factores Socioeconómicos , Serodiagnóstico de la Sífilis , Treponema pallidum/inmunología , Treponema pallidum/aislamiento & purificación
11.
Transfusion ; 59(9): 2833-2839, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31393616

RESUMEN

BACKGROUND: AABB Standards for Blood Banks and Transfusion Services require accredited institutions to have a policy for handling requests for blood components on patients clinically identified as being at high risk for transfusion-associated circulatory overload (TACO; Standard 5.19.7, 31st edition). This survey elucidated how AABB accredited hospital transfusion services/blood banks around the world are complying with this Standard. METHODS: A link to a Web-based survey in English was e-mailed under the auspice of the AABB to each AABB accredited hospital transfusion service/blood bank (n = 851) asking for details on how their institution is complying with this Standard and for general information on any TACO risk mitigation strategies in place. RESULTS: Of the 290 responses received (34% response rate), 282 met the criteria for analysis. There were 174 of 282 (62%) respondents who indicated that their institution has a formal policy for complying with the Standard, and 108 of 282 (38%) who indicated that their institution does not have a formal policy. A diverse range of policies and practices were in place at the institutions with and without a formal policy ranging from writing advice/recommendations in the charts of patients at increased risk of TACO, promulgating policies from the transfusion service/blood bank or institution itself that would reduce the risk, or using decision support tools to provide education about reducing the risk of TACO. CONCLUSIONS: Many but not all AABB accredited institutions have policies to comply with the TACO risk mitigation Standard. However, the vast majority conduct activities that could mitigate risk for TACO.


Asunto(s)
Transfusión Sanguínea/normas , Adhesión a Directriz/organización & administración , Hospitales/normas , Política Organizacional , Gestión de Riesgos/organización & administración , Gestión de Riesgos/normas , Reacción a la Transfusión/terapia , Bancos de Sangre/organización & administración , Bancos de Sangre/normas , Seguridad de la Sangre/métodos , Seguridad de la Sangre/normas , Canadá/epidemiología , Colombia/epidemiología , Humanos , Italia/epidemiología , Pakistán/epidemiología , Gestión de Riesgos/métodos , Arabia Saudita/epidemiología , Singapur/epidemiología , Sociedades Médicas/organización & administración , Sociedades Médicas/normas , Reacción a la Transfusión/epidemiología , Reacción a la Transfusión/etiología , Estados Unidos/epidemiología
12.
Biomédica (Bogotá) ; Biomédica (Bogotá);39(supl.1): 163-171, mayo 2019. tab, graf
Artículo en Español | LILACS | ID: biblio-1038820

RESUMEN

Resumen Introducción. La sífilis es una enfermedad de interés en salud pública por sus elevadas tasas de morbilidad y mortalidad. Objetivo. Determinar la serorreacción y la seroprevalencia de sífilis según las variables sociodemográficas de los donantes de un banco de sangre del distrito de Barranquilla, Colombia, durante 2015 y 2016. Materiales y métodos. Se hizo un estudio descriptivo de corte transversal basado en los resultados de las pruebas treponémicas y no treponémicas. Se analizaron las variables sociodemográficas de la población estudiada y se hizo un análisis univariado en el que se determinaron las frecuencias absoluta y relativa de cada una de las variables categóricas. Se determinó la serorreacción a Treponema pallidum y la prevalencia de la infección activa. Se utilizó la prueba de ji al cuadrado de Pearson para evaluar las diferencias entre las proporciones. Resultados. Se encontró una serorreacción de 1,86 % para la infección previa con T. pallidum y una prevalencia de 0,93 % para la infección activa, las cuales fueron más altas en hombres adultos y en adultos mayores, viudos, desempleados y personas residentes en otros municipios del departamento de Atlántico diferentes de Barranquilla y su área metropolitana. Se encontró una asociación significativa entre la sífilis y las variables de sexo y ocupación. Conclusión. Se registró una serorreacción elevada a T. pallidum en donantes de sangre, comparada con el promedio nacional. Se encontró asociación entre la sífilis, y las variables sociodemográficas de sexo y ocupación, principalmente.


Abstract Introduction: Syphilis is a public health concern given its high impact on morbidity and mortality. Objective: We aimed to determine the association of syphilis seroreactivity and seroprevalence with sociodemographic variables of donors at a blood bank in the district of Barranquilla, Colombia, during 2015 and 2016. Materials and methods: We conducted a descriptive cross-sectional study based on the results of the treponemal and nontreponemal tests and the sociodemographic variables of the study population. We performed a univariate analysis to determine the absolute and relative frequencies for each categorical variable. We determined the seroreactivity against Treponema pallidum and the prevalence of active syphilis infection, and we used Pearson's chi-square test to evaluate the differences between the proportions. Results: We found a seroreactivity of 1.86% in individuals with previous T. pallidum infection, and a prevalence of 0.93% in those with active T. pallidum infection. These values were higher in adult men and older adults, widowers, the unemployed, and people living in municipalities of the Department of Atlántico other than Barranquilla and its metropolitan area. The incidence of syphilis infection showed a significant association with sex and occupation. Conclusion: In comparison to the national average, syphilis seroreactivity was high among blood donors. There was an association between syphilis infection incidence and sociodemographic variables such as sex and occupation.


Asunto(s)
Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Bancos de Sangre , Donantes de Sangre , Sífilis/epidemiología , Factores Socioeconómicos , Treponema pallidum/aislamiento & purificación , Treponema pallidum/inmunología , Bancos de Sangre/normas , Serodiagnóstico de la Sífilis , Estudios Seroepidemiológicos , Prevalencia , Estudios Transversales , Determinantes Sociales de la Salud , Anticuerpos Antibacterianos/sangre , Anticuerpos Antibacterianos/inmunología
13.
Transfus Apher Sci ; 57(1): 97-101, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29452838

RESUMEN

INTRODUCTION: Quality control for the detection of infectious markers in blood banks is a necessary activity to ensure the accuracy of donor screening results. Considering that in Mexico blood safety is one of the goals of the National Action Programs, it is essential to evaluate banks through an External Quality Control Program. OBJECTIVE: To analyze one of the evaluations that showed the greatest participation (2014-2/lot46) of banks in the Mexican Republic in the detection of transfusion-transmitted diseases. MATERIALS AND METHODS: A randomized panel of infectious markers of HIV, HCV, HBV, Treponema pallidum and Trypanosoma cruzi was manufactured under high quality standards. The evaluation criteria for each infectious marker were the identification of false positives and false negative results. Additionally, technologies used to detect infectious markers were requested for each bank. RESULTS: Of the 503 banks, only 374 participated in the evaluation. Technologies based on chemiluminescence, immunofluorescence and immunocolorimetry were used to detect viral markers. Even rapid tests for T. pallidum continue to be the methods of choice with 42%. Trypanosoma cruzi was 20% with fast techniques versus 80% with automated tests. Highest incidence of false positives was identified for T. pallidum and HBV, followed by T. cruzi, HIV and HCV. Fourteen (3.74%) false negatives results were identified for T. cruzi, followed by T. pallidum (n = 5/1.33%), HCV (n = 4/1.06) and HVB/HIV (n = 2/0.53%). CONCLUSION: False positive results identified for each infectious marker was considered high. This evidence will allow us to focus on areas of opportunity during serologic screening with greater emphasis on good laboratory practices.


Asunto(s)
Almacenamiento de Sangre/métodos , Bancos de Sangre/normas , Seguridad de la Sangre/métodos , Seguridad de la Sangre/normas , Infecciones/sangre , Infecciones/diagnóstico , Biomarcadores/sangre , Femenino , Humanos , Masculino , México , Control de Calidad
15.
Cienc. tecnol. salud ; 4(1): 15-50, 20170600. ilus
Artículo en Español | LILACS | ID: biblio-882820

RESUMEN

La transmisión de infecciones por vía transfusional (sangre y derivados plasmáticos) es una complicación de gran importancia en relación con la morbimortalidad en receptores de sangre, lo que ha creado la necesidad de establecer estrategias de prevención que reduzcan o eliminen este riesgo. Como enfoque principal este estudio pretendió determinar la prevalencia del virus linfotrópico de células T humanas (HTLV) I/II en donantes que acuden a un banco de sangre hospitalario, además de abordar de manera documental y experimental la importancia de la implementación de dicha prueba, durante el tamizaje rutinario para unidades de sangre. Se utilizó el inmunoanálisis quimioluminiscente de micropartículas (CMIA) que detecta la presencia de anticuerpos contra antígenos del HTLV-I/II en el suero del donante y que se basa en la emisión de quimioluminiscencia. En el periodo de estudio se realizaron 650 pruebas que representan el 6.5% del total anual de donantes atendidos en un banco de sangre hospitalario. Los resultados indicaron que la prevalencia del HTLV I/II en esta muestra de donantes fue de 0.15%, con un intervalo de confianza del 95-99.5% [0.14, 0.29], sugiriendo que la inclusión de la determinación de HTLV I/II en las pruebas obligadas por la Ley de Servicios de Medicina Transfusional y Bancos de Sangre, Decreto 87-97 de Guatemala es de importancia considerando los datos obtenidos y analizados.


The infections transmitted via blood transfusion (blood and plasma derivatives) are a complication of great importance in relation to morbidity and mortality in blood recipients, what has created the need to establish prevention strategies that reduce or eliminate this risk. The main focus of this study was to determine the prevalence of Human T-Lymphotropic Virus HTLV I/II among blood donors who attend a Hospital Blood Bank, in addition to addressing in a documental and experimental way, the importance of the implementation of this test during the routine screening of blood units. To this end, a chemiluminescent microparticle immunoassay (CMIA) was used to detect the presence of antibodies to HTLV-I/II in plasma from donors. In the study period, 650 samples were tested, representing 6.5% of total annual donors attending the Hospital Blood Bank. Results indicated that the prevalence of the Human T-Lymphotropic Virus HTLV I/II in this population was 0.15%, with the confidenceinterval of 95-99.5% [0.14, 0.29], suggesting that the inclusion of the determination of HTLV I/II in tests required by the Law of Services of Transfusion Medicine and Blood Banks, Decree 87-97 of Guatemala is of importance considering the data obtained and analyzed.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Adulto Joven , Bancos de Sangre/normas , Transfusión Sanguínea/mortalidad , Infecciones por Retroviridae/sangre , Transmisión de Enfermedad Infecciosa/prevención & control
16.
Rev Panam Salud Publica ; 40(1): 1-8, 2016 Aug.
Artículo en Portugués | MEDLINE | ID: mdl-27706392

RESUMEN

Objective To describe the sanitary status of Brazilian blood establishments (BE) assessed by the national health surveillance system in 2013. Method In the present descriptive study, the sanitary profile of BE was assessed using the Blood Establishment Potential Risk Assessment Method (Método de Avaliação de Risco Potencial de Serviços de Hemoterapia, MARPSH), developed by the National Sanitary Surveillance Agency (Anvisa). The MARPSH involves the evaluation of 471 structure and process items to produce an assessment of potential risk associated with critical control points in the blood cycle (vein-to-vein). Based on this assessment, BE are classified into five risk categories: low, medium-low, medium, medium-high, and high. The results were analyzed regarding the type of service (considering all levels, from coordinating centers to collection units), type of financing (public/private) and geographic region. Results Of the existing BE, 1 212 (60%) were assessed in 2013. Of these, 81% met ≥ 70% of the sanitary requirements (satisfactory status, corresponding to medium, medium-low, and low risk categories). Transfusion agencies (hospital units with the role of storing, running compatibility tests between donors and recipients, and transfusing blood components) and public establishments had the highest number of non-conformity structure and process items. Conclusion The use of the MARPSH facilitated the assessment of BE in Brazil and revealed objective opportunities for improvement. These gaps should be addressed by regulating authorities, especially in public services.


Asunto(s)
Bancos de Sangre/normas , Bancos de Sangre/legislación & jurisprudencia , Brasil , Humanos , Higiene/legislación & jurisprudencia , Higiene/normas , Mejoramiento de la Calidad , Medición de Riesgo
18.
Lima; s.n; 2013. 35 p. tab, graf.
Tesis en Español | LILACS, LIPECS | ID: lil-707812

RESUMEN

OBJETIVO: El objetivo del presente Trabajo de Investigación ha sido realizar el Control de Calidad del Volumen de los diferentes hemocomponentes obtenidos mediante el Equipo Fraccionador Automatizado COMPOMAT en el Servicio de Hemoterapia y Banco de Sangre del Hospital Nacional Daniel A. Carrión durante el año 2011, el mismo que se ha desarrollado en forma individualizada, considerando exclusivamente el volumen y en el 100 por ciento de hemocomponentes producidos. MATERIALES Y METODOS: Para la realización del presente Trabajo de Investigación se ha utilizado el Equipo Automatizado COMPOMAT con el programa de fraccionamiento para Bolsas colectoras de sangre cuádruples con anticoagulante SAG Manitol y sistema de tubuladura superior e inferior (TOP and BOTTOM). Al realizar el procedimiento se registró todos los volúmenes de los hemocomponentes fraccionados como son 2140 unidades de paquete globular, 2093 unidades de plasma fresco congelado y 1851 concentrados de plaquetas. El trabajo se desarrolló en el área de fraccionamiento sanguíneo del Servicio de Hemoterapia y Banco de Sangre del Hospital Nacional Daniel A. Carrión de la Región Callao, durante el periodo comprendido desde el mes de Octubre del año 2010 al mes de Marzo del año 2011 en que los datos obtenidos fueron registrados manualmente en un programa Microsoft Excel 2007 para el procesamiento de los mismos y para la realización de Curvas de Control de Calidad de Levey Jennings. RESULTADOS: De los 2140 paquetes globulares procesados, un 77 por ciento cumple con los parámetros de calidad establecidos para volumen. De los 2092 plasmas frescos congelados, el 98 por ciento cumple con los parámetros de calidad establecidos para volumen. De los 1851 concentrados de plaquetas procesadas, el 95 por ciento cumple con los parámetros de calidad establecidos para volumen. CONCLUSIONES: Se concluye que el volumen de los hemocomponentes obtenidos, tanto Paquete Globular, como Plasma Fresco Congelado y Plaquetas, cumple...


Asunto(s)
Humanos , Bancos de Sangre/normas , Control de Calidad , Determinación del Volumen Sanguíneo , Transfusión de Componentes Sanguíneos/normas , Estudios Prospectivos , Estudios Transversales
19.
Transfusion ; 52(12): 2606-13, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22486418

RESUMEN

BACKGROUND: Umbilical cord blood (UCB) represents an alternative source of stem cells for transplantation for the treatment of hematologic malignancies and genetic disorders. There is scarce information detailing cord blood bank (CBB) collection and transplantation activities from developing countries. We documented our experience at a public university hospital in northeast Mexico. STUDY DESIGN AND METHODS: We carried out a retrospective and descriptive analysis of our CBB activity during an 8-year period from May 2002 to September 2010. Collection, processing, and cryopreservation of CB were carried out following standard operating procedures. The minimum volume and total nucleated cell (TNC) content for cryopreservation were 80 mL and 8.0 × 10(8) , respectively. RESULTS: A total of 1256 UCB units were collected; 428 (34%) were banked and 828 (66%) were discarded. The main reason for exclusion was biologic: low volume and/or low number of TNC accounted for 84% of the total discarded units. Cryopreserved cord blood units (CBUs) had a median volume of 113.8 mL (range, 80-213.2 mL) and 13.0 × 10(8) (range, 8 × 10(8) -36.6 × 10(8) ) TNCs. Cell viability was 99.3% (88-100%). The median CD34+ cell content was 4.0 × 10(6) (0.46 × 10(6) -19.38 × 10(6) ). Sixteen units have been released for transplantation, leading to a utilization rate of 3.7%. CONCLUSION: CBB demands considerable human and financial resources; it is then essential for centers at developing countries to share their experience, results, and databases to increase the probability of finding matching units for their patients. Efforts to create and maintain CBBs allow to offer this therapeutic option at an affordable cost.


Asunto(s)
Almacenamiento de Sangre/métodos , Donantes de Sangre/estadística & datos numéricos , Trasplante de Células Madre de Sangre del Cordón Umbilical/estadística & datos numéricos , Sangre Fetal/citología , Hospitales Universitarios/estadística & datos numéricos , Adolescente , Adulto , Bancos de Sangre/economía , Bancos de Sangre/normas , Donantes de Sangre/provisión & distribución , Trasplante de Células Madre de Sangre del Cordón Umbilical/economía , Trasplante de Células Madre de Sangre del Cordón Umbilical/normas , Análisis Costo-Beneficio , Criopreservación , Bases de Datos Factuales/estadística & datos numéricos , Países en Desarrollo/estadística & datos numéricos , Femenino , Hospitales Universitarios/economía , Hospitales Universitarios/normas , Humanos , México , Embarazo , Estudios Retrospectivos , Adulto Joven
20.
Rev. bras. hematol. hemoter ; Rev. bras. hematol. hemoter;34(2): 80-85, 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-624763

RESUMEN

BACKGROUND: Despite significant advances, the practice of blood transfusion is still a complex process and subject to risks. Factors that influence the safety of blood transfusion include technical skill and knowledge in hemotherapy mainly obtained by the qualification and training of teams. OBJECTIVE: This study aimed to investigate the relationship between professional categories working in transfusion services of the public blood bank network in the State of Minas Gerais and their performance in proficiency tests. METHODS: This was an observational cross-sectional study (2007-2008) performed using a specific instrument, based on evidence and the results of immunohematology proficiency tests as mandated by law. RESULTS: The error rates in ABO and RhD phenotyping, irregular antibody screening and cross-matching were 12.5%, 9.6%, 43.8% and 20.1%, respectively. When considering the number of tests performed, the error rates were 4.6%, 4.2%, 26.7% and 11.0%, respectively. The error rates varied for different professional categories: biochemists, biologists and biomedical scientists (65.0%), clinical pathology technicians (44.1%) and laboratory assistants, nursing technicians and assistant nurses (74.6%). A statistically significant difference was observed when the accuracy of clinical pathology technicians was compared with those of other professionals with only high school education (p-value < 0.001). This was not seen for professionals with university degrees (p-value = 0.293). CONCLUSION: These results reinforce the need to invest in training, improvement of educational programs, new teaching methods and tools for periodic evaluations, contributing to increase transfusion safety and improve hemotherapy in Brazil.


Asunto(s)
Humanos , Transfusión Sanguínea , Bancos de Sangre/normas , Control de Calidad , Medidas de Seguridad , Tutoría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA