1.
J Indian Soc Pedod Prev Dent ; 42(3): 249-254, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39250210

RESUMEN

BACKGROUND: Uncomplicated crown fractures of maxillary anterior teeth are common dental injuries, and the bonding of fractured fragments is recommended for management. Rehydration of fragments improves bonding and fracture resistance. Therefore, the aim of this study was to compare the fracture resistance of the reattached tooth fragment of the incisor crown after rehydration using either a steamer or a humidifier. MATERIALS AND METHODS: Bovine teeth were used as a model. Fractured fragments were divided into three groups: Group I (no rehydration), Group II (rehydration by humidifier), and Group III (rehydration by steamer). Fragments were reattached using a standard bonding protocol. Fracture resistance was tested using a universal testing machine. Statistical analysis was performed using analysis of variance and Chi-square tests. RESULTS: The force required to fracture the reattached fragments was significantly higher in Group II (humidifier) compared to Group I (no rehydration) (P = 0.005). Group III (steamer) had a force value similar to Group I, indicating no significant improvement in fracture resistance with steamer rehydration. The temperature inside the steam-based chamber reached an average of 95.7°C with 95% humidity, whereas the conventional humidification chamber had an average temperature of 39.2°C and 84% humidity. CONCLUSION: Within the limitations of the present study, the rehydration protocol using a steam-based chamber was found to have a significantly lower force required to fracture the reattached fragments as compared to humidifier-based chamber. This was not significantly different from the fragments which were reattached without rehydration.


Asunto(s)
Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Temperatura , Corona del Diente , Fracturas de los Dientes , Bovinos , Fracturas de los Dientes/terapia , Animales , Corona del Diente/lesiones , Técnicas In Vitro , Recubrimiento Dental Adhesivo/métodos , Incisivo/lesiones , Fluidoterapia/métodos , Humedad
2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(4): 766-774, 2024 Aug 25.
Artículo en Chino | MEDLINE | ID: mdl-39218603

RESUMEN

The locking mechanism between bracket and shape memory alloy (SMA) archwire in the newly developed domestic orthodontic device is the key to controlling the precise alignment of the teeth. To meet the demand of locking force in clinical treatment, the tightening torque angle of the locking bolt and the required torque magnitude need to be precisely designed. For this purpose, a design study of the locking mechanism is carried out to analyze the correspondence between the tightening torque angle and the locking force and to determine the effective torque value, which involves complex coupling of contact, material and geometric nonlinear characteristics. Firstly, a simulation analysis based on parametric orthogonal experimental design is carried out to determine the SMA hyperelastic material parameters for the experimental data of SMA archwire with three-point bending. Secondly, a two-stage fine finite-element simulation model for bolt tightening and archwire pulling is established, and the nonlinear analysis is converged through the optimization of key contact parameters. Finally, multiple sets of calibration experiments are carried out for three tightening torsion angles. The comparison results between the design analysis and the calibration experiments show that the deviation between the design analysis and the calibration mean value of the locking force in each case is within 10%, and the design analysis method is valid and reliable. The final tightening torque angle for clinical application is determined to be 10° and the rated torque is 2.8 N∙mm. The key data obtained can be used in the design of clinical protocols and subsequent mechanical optimization of novel orthodontic devices, and the research methodology can provide a valuable reference for force analysis of medical devices containing SMA materials.


Asunto(s)
Análisis de Elementos Finitos , Alambres para Ortodoncia , Torque , Aleaciones con Memoria de Forma , Humanos , Soportes Ortodóncicos , Diseño de Aparato Ortodóncico , Estrés Mecánico , Ensayo de Materiales , Simulación por Computador , Análisis del Estrés Dental
3.
BMC Oral Health ; 24(1): 1065, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39261857

RESUMEN

BACKGROUND: Recently, prosthodontic approaches involve more conservative procedures that include less invasive finish line preparations that use less ceramic thickness. AIM OF THE STUDY: This in vitro study aimed to evaluate the effect of vertical preparation and modified vertical preparation designs on the marginal adaptation and fracture resistance of two types of ceramic crowns using CAD/CAM technology. MATERIALS AND METHODS: Two typodont maxillary first premolars were embedded in acrylic resin. Forty positive replicas of epoxy resin dies were used that were divided into two groups depending on the preparation design (n = 20); Group V (Vertical): dies with feather edge finish line and Group MV (Modified vertical): dies with feather edge finish line, where a reverse shoulder of 1 mm depth was placed on the buccal surface 1.5 mm from the occlusal surface. Each group was further subdivided into two subgroups according to the type of ceramic material (n = 10): Subgroup Va and subgroup MVa for lithium disilicate (e.max CAD) and subgroup Vb and subgroup MVb for zirconia (zolid ht+). Crown restorations were made with CAD-CAM technology. The marginal adaptation was assessed using a stereomicroscope both prior to cementation and after cementation and aging. Fracture resistance was tested with a universal testing machine, and the data were statistically analyzed. RESULTS: Marginal adaptation showed no significant differences between subgroups before or after cementation and aging. Three-way ANOVA indicated that preparation design (p = 0.516) and material (p = 0.269) had no significant effect, but cementation had a significant effect (p < 0.0001) on the marginal adaptation. According to two-way ANOVA test, Subgroup (MVb) showed the highest result followed by subgroup (Vb) and subgroub (MVa) and the least was subgroub (Va). Fracture modes showed no significant differences among the subgroups (p = 0.982). CONCLUSIONS: Marginal adaptation of lithium disilicate and zirconia crowns remained clinically acceptable regardless of preparation design. While the modified vertical preparation with a reverse shoulder notably enhanced the fracture resistance of both materials, with zirconia demonstrating superior fracture resistance compared to lithium disilicate with average values exceeding premolar biting force.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Coronas , Adaptación Marginal Dental , Porcelana Dental , Diseño de Prótesis Dental , Análisis del Estrés Dental , Circonio , Circonio/química , Porcelana Dental/química , Humanos , Técnicas In Vitro , Cerámica/química , Fracaso de la Restauración Dental , Ensayo de Materiales , Diente Premolar
4.
Angle Orthod ; 94(4): 408-413, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39229953

RESUMEN

OBJECTIVES: To investigate the effects of transpalatal (TPA) wire dimension and temporary skeletal anchorage device (TSAD) position on maxillary molar intrusion. MATERIALS AND METHODS: The maxillary molar intrusion measurement system included a maxillary acrylic model, TPA, TSADs, and a three-dimensional Force/Moment (F/M) sensor. The intrusion patterns were categorized into six groups: buccal-mesial, buccal-distal, buccal-mesiodistal, palatal-mesial, palatal-distal, and palatal-mesiodistal. TPA wire dimensions were designed to be 0.7 mm, 0.9 mm, and 1.2 mm. The force and moment loads of the maxillary first molar were measured by the F/M sensor. RESULTS: Single buccal or palatal TSADs induced torquing movement, and single mesial or distal TSADs tended to promote tipping movement. Mesiodistal TSADs would have eliminated tipping, but accentuated torquing movement. The TPA significantly reduced the force and moment experienced by the maxillary first molar along three-dimensional axes. The thicker the TPA wire, the smaller the force and moment to which the maxillary first molar was subjected. CONCLUSIONS: Precise placement of TSADs might have a substantial influence on tooth movement and should be determined in accordance with specific clinical requirements. Increasing the TPA wire dimension could diminish the tipping, torquing, and rotation during TSAD-assisted maxillary molar intrusion, but these tendencies could not be completely eliminated.


Asunto(s)
Maxilar , Diente Molar , Métodos de Anclaje en Ortodoncia , Diseño de Aparato Ortodóncico , Alambres para Ortodoncia , Técnicas de Movimiento Dental , Técnicas de Movimiento Dental/instrumentación , Técnicas de Movimiento Dental/métodos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Humanos , Modelos Dentales , Análisis del Estrés Dental
5.
Dental Press J Orthod ; 29(4): e242462, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39230115

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the shear bond strength of metal brackets bonded with indirect bonding, under different surface treatment protocols. MATERIAL AND METHODS: 40 bovine teeth were randomly divided into four groups (n = 10), according to the type of surface treatment: G1 = 70% alcohol, G2 = air/water spray, G3 = 100-µm aluminum oxide blasting, G4 = direct boning. After drying, the standard Edgewise central incisor brackets were bonded with light-cured resin. The brackets were moved from the plaster models by means of a transfer tray made with condensation silicone, and bonded to the surface of the enamel with self-curing adhesive. The samples were submitted to shear tests by a universal test machine. Data were analyzed with SPSS 20.0 by the one-way ANOVA test and the Tukey post-test. RESULTS: No statistically significant difference (p=0.174) was observed between the mean forces measured between the group for shear strength values of the groups during the test: G1 (5.33 MPa), G2 (3.52 MPa) and G3 (4.58 MPa). CONCLUSION: The bracket surface treatment protocols presented similarities in shear bond strength test. However, alcohol 70% and oxide blasting presented higher absolute values of resistance than the water group.


Asunto(s)
Recubrimiento Dental Adhesivo , Esmalte Dental , Soportes Ortodóncicos , Resistencia al Corte , Propiedades de Superficie , Animales , Bovinos , Esmalte Dental/efectos de los fármacos , Recubrimiento Dental Adhesivo/métodos , Óxido de Aluminio/química , Análisis del Estrés Dental , Ensayo de Materiales , Cementos de Resina/química , Etanol , Agua/química , Distribución Aleatoria
6.
Dental Press J Orthod ; 29(4): e242458, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39230114

RESUMEN

OBJECTIVE: Evaluate the load mini-implants exert on the artificial bone when expanding the MARPE EX in three different extension arm configurations. METHODS: A device simulating the human palate was fabricated and attached to a universal testing machine, for conducting tests with different MARPE expanders (n=5): non-adjustable/control (MARPE SL, Peclab) or with low, intermediate, and high extender arms (MARPE EX, Peclab). The expanders were manually activated until failure of the device occurred, and maximum load values were recorded. Load averages were also calculated for every five activations until the twentieth activation. RESULTS: The generalized linear mixed model for repeated measures over time showed that there was significant increase in load with activations for all expanders (p=0.0004). Up to the twentieth activation, the expander with low extender arms presented higher load than the others, while the expander with high extender arms showed lower load values (p<0.05). There was no significant difference among expanders regarding the number of activations (p=0.0586), although there was a trend towards fewer activations until fracture for the control expander. It was observed that the higher the configuration, the lower the force the mini-implants delivered to the bone. The control expander provided a force magnitude similar to that of the adjustable expander when positioned at the intermediate height. CONCLUSIONS: The activation load of MARPE expanders is influenced by the type of presentation of the extensor arms, with higher configurations resulting in lower force delivered by the mini-implants to the bone.


Asunto(s)
Análisis del Estrés Dental , Diseño de Aparato Ortodóncico , Técnica de Expansión Palatina , Humanos , Técnica de Expansión Palatina/instrumentación , Ensayo de Materiales , Estrés Mecánico , Implantes Dentales
7.
BMC Oral Health ; 24(1): 1078, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39272065

RESUMEN

BACKGROUND: Partial coverage concepts have met the main goal of conservative dentistry. Vonlays, which combine features of veneers and onlays, are a recent alternative to full coverage designs and overlay partial coverage restorations. This in vitro study was conducted to compare the fracture resistance of the newly introduced pressable zirconia-reinforced lithium silicate with pressable lithium disilicate ceramic and to determine the optimal preparation design for partial coverage on upper premolars. METHODS: Fifty-two duplicated epoxy resin dies were prepared following vonlay and overlay preparation guidelines. For each preparation (n = 26), the specimens were divided into two subgroups to be restored with lithium disilicate (IPS e.max Press) or zirconia-reinforced lithium silicate (Vita Ambria) (n = 13 each). Ceramic vonlays and overlays were bonded using dual cure resin cement, subjected to thermomechanical fatigue, and the load to fracture was tested by using a universal testing machine. The specimens were fractographically analyzed via scanning electron microscopy (SEM). The normality of the fracture resistance data was checked using the Shapiro‒Wilk test and Q‒Q plots, and two-way ANOVA was used to assess the effect of the type of preparation and ceramic material on the fracture resistance. RESULTS: The group of overlays restored with zirconia-reinforced lithium silicate showed the highest mean fracture load (1218.69 N), while the group of vonlays restored with lithium disilicate had the lowest mean fracture resistance (967.15 N). The effect of preparation design and material type on fracture resistance was significant for both factors, p = 0.003 and p < 0.0001, respectively. Different features of the fracture surfaces, such as arrest lines, hackles, and directions of crack propagation, were observed. CONCLUSIONS: Zirconia-reinforced lithium silicate exhibited greater resistance to fracture compared to lithium disilicate, making it a potential substitute for partial coverage restorations. Additionally, the overlay showed superior fracture resistance when compared to the vonlay preparation design.


Asunto(s)
Diente Premolar , Cerámica , Porcelana Dental , Análisis del Estrés Dental , Ensayo de Materiales , Circonio , Cerámica/química , Porcelana Dental/química , Circonio/química , Humanos , Técnicas In Vitro , Fracaso de la Restauración Dental , Microscopía Electrónica de Rastreo , Maxilar , Diseño de Prótesis Dental , Incrustaciones , Coronas con Frente Estético
8.
J Clin Pediatr Dent ; 48(5): 102-109, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39275826

RESUMEN

Nickel-titanium (NiTi) instruments offer many advantages during endodontic instrumentation; however, the fracture risk within the canal remains a concern. Manufacturers continuously develop and introduce instruments to the market with supposedly enhanced cyclic fatigue resistance and increased flexibility, achieved through different proprietary manufacturing processes, the details of which have not been made public. In recent years, two rotary systems specially designed for deciduous teeth have been commercially available, but information about their performance is lacking. This investigation aimed to identify which manufacturing process provides better cyclic fatigue resistance: the AF-H Wire technology used in the AF baby rotary files (AF-f) or the CM-Wire technology used in the i3 Gold deciduous teeth rotary files (i3G-f). Forty rotary International Organization for Standardization (ISO) 25/04 files were tested in artificial canals with a standard geometry of 60° angle and 2.5 mm radius until fracture. The number of cycles to fracture was calculated, and the length of the fragments was measured. A scanning electron microscope (SEM) was used to examine the fracture surfaces and fragments. Energy dispersive spectroscopy (EDS) was used to determine the percentage weight of NiTi in each file. The statistical analysis (Mann-Whitney test) showed that the cyclic fatigue resistance of the AF-f was significantly higher (p < 0.0001) than that of the i3G-f. Additionally, there was a significant difference (p = 0.0419) in the length of the fractured fragments. All instruments showed one or more types of manufacturing defects and presented similar NiTi percentages by weight. The manufacturing process is critical to cyclic fatigue resistance, and there seems to be responsible for the difference in cyclic fatigue resistance between these similar instruments.


Asunto(s)
Falla de Equipo , Calor , Níquel , Preparación del Conducto Radicular , Titanio , Preparación del Conducto Radicular/instrumentación , Níquel/química , Humanos , Titanio/química , Diseño de Equipo , Ensayo de Materiales , Instrumentos Dentales , Microscopía Electrónica de Rastreo , Aleaciones Dentales/química , Técnicas In Vitro , Análisis del Estrés Dental
9.
J Clin Pediatr Dent ; 48(5): 166-173, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39275834

RESUMEN

To investigate the effects of lactic acid etching on the immediate and aged bond strength of the resin-dentin bonding interface, the resin-dentin bonding interface was evaluated 24 hours and 6 months later. A total of 42 isolated third molars were randomly divided into 6 experimental groups according to different lactate concentration (35%, 40%, 45%) and acid etching time (30 s, 45 s), with 37% phosphoric acid etching 15 s as a control. In each group, dentin samples were etched under different acidic conditions and bonded with Adper Single Bond 2 (3M ESPE) as directed. The immediate group was immediately stored in deionized water at 37 °C for 24 h, and the aging group was stored in artificial saliva at 37 °C for 6 months. Immediate and aged bond strengths were measured by a micro-tensile tester, and the specimen fracture surface was observed under a microscope. 14 isolated third molars were randomly divided into 7 groups, and each group was etched with acid. Collagen fibers morphology in dentin was examined after gradient dehydration with ethanol by scanning electron microscopy (SEM). Statistically, there was no difference between the resin-dentin immediate bonding strength of 35% lactic acid for 30 s and 37% phosphoric acid for 15 s, but the aged bond strength was greater than that of the phosphoric acid group. According to scanning electron microscope observations, the collagen fiber morphology in 35% and 40% lactate etching dentin 30 s groups was relatively intact compared with other groups. In conclusion, 35% lactic acid etching of dentin 30 s ensures both immediate and aged resin-dentin bond strength.


Asunto(s)
Grabado Ácido Dental , Recubrimiento Dental Adhesivo , Dentina , Ácido Láctico , Microscopía Electrónica de Rastreo , Resistencia a la Tracción , Humanos , Ácido Láctico/química , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental/métodos , Factores de Tiempo , Ácidos Fosfóricos/química , Recubrimientos Dentinarios/química , Tercer Molar , Ensayo de Materiales , Análisis del Estrés Dental , Propiedades de Superficie , Cementos de Resina/química , Cementos Dentales
10.
BMC Oral Health ; 24(1): 1059, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39256714

RESUMEN

BACKGROUND: Implant-retained obturators for maxillectomy cases have several advantages over traditional obturators but prosthetic design for specific conditions after maxillary resection has several challenges and the appropriate implant placement configuration is essential for improving retention and the stability of the implant-retained obturator. OBJECTIVES: The present study aimed to assess the retention force of using linear and nonlinear implant placement configurations using ball and socket attachment in implant-retained obturators at the initial retention and after simulation of six months of use. MATERIALS AND METHODS: Two identical epoxy resin maxillary models of a completely edentulous unilateral maxillary defect (Brown's class IIb) were used for implant placement, in the first model three implants were arranged with linear placement configuration, and in the second model three implants were arranged in nonlinear placement configuration. For proper sample sizing, 26 models and obturator were used. Two equal groups of obturators (13 for each group) were constructed, each with a different implant placement configuration. Both groups used the same attachment design (a non-splinted ball attachment). Using a cyclic loading machine that served as a dental insertion and removal simulator, each study group was subjected to 500 tension-compression cycles simulating 6 months of use. Using the universal testing machine, each obturator was removed at a speed of 50 mm/min for the crosshead. peak load to dislodgement was measured at the initial retention and after the simulations of six months of use. Data were analyzed using independent and paired t-tests while percent change was analyzed using the Mann Whitney U test. RESULTS: There were a statistically significant differences in retention between the nonlinear implant placement configuration for Brown's class IIb maxillectomy and the linear implant placement configuration at initial retention evaluation with p-value of < 0.0001 and after simulation of six months of usage with p-value of < 0.0001 Also, after simulation of 6 months of use group I lose - 24.87 (10.16) % of its retention while group II lose - 17.49 (7.78) %. CONCLUSIONS: Non-linear implant placement is more retentive at the initial retention and after simulation of six months of use than linear and loses less retention after usage.


Asunto(s)
Retención de Prótesis Dentales , Maxilar , Obturadores Palatinos , Humanos , Maxilar/cirugía , Diseño de Prótesis Dental , Análisis del Estrés Dental , Prótesis Dental de Soporte Implantado , Técnicas In Vitro , Implantación Dental Endoósea/métodos
11.
BMC Oral Health ; 24(1): 1055, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39251975

RESUMEN

BACKGROUND: The purpose of this in vitro study was to investigate the effect of polishing post-treatment process on the torque loss ratio and microgap of Selective Laser Melting (SLM) abutments before and after mechanical cycling test through improving the surface roughness of the implant-abutment interface. MATERIALS AND METHODS: Forty SLM abutments were fabricated, with 20 underwent minor back-cutting, designated as polishing, in the implant-abutment interface. The abutments were divided into three groups: SLM abutments (group A), original abutments (group B), and polished SLM abutments (group C), each containing 20 abutments. Surface roughness was evaluated using a laser microscope. Implant-abutment specimens were subjected to mechanical cycling test, and disassembly torque values were measured before and after. Scanning electron microscope (SEM) was used to measure microgap after longitudinal sectioning of specimens. Correlation between surface roughness, torque loss ratio, and microgap were evaluated. LSD's test and Tamhane's T2 comparison were used to analyze the data (α = 0.05). RESULTS: The Sz value of polished SLM abutments (6.86 ± 0.64 µm) demonstrated a significant reduction compared to SLM abutments (26.52 ± 7.12 µm). The torque loss ratio of polished SLM abutments (24.16%) was significantly lower than SLM abutments (58.26%), while no statistically significant difference that original abutments (18.23%). The implant-abutment microgap of polished SLM abutments (2.38 ± 1.39 µm) was significantly lower than SLM abutments (8.69 ± 5.30 µm), and this difference was not statistically significant with original abutments (1.87 ± 0.81 µm). A significant positive correlation was identified between Sz values and the ratio of torque loss after cycling test (r = 0.903, P < 0.01), as well as Sz values and the microgap for all specimens in SLM abutments and polished SLM abutments (r = 0.800, P < 0.01). CONCLUSION: The findings of this study indicated that the polishing step of minor back-cutting can lead to a notable improvement in the roughness of SLM abutments interface, which subsequently optimized the implant-abutment fit. It can be seen that the application of minor back-cutting method has advanced the clinical use of SLM abutments.


Asunto(s)
Pilares Dentales , Diseño de Implante Dental-Pilar , Pulido Dental , Rayos Láser , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Torque , Técnicas In Vitro , Pulido Dental/métodos , Humanos , Ensayo de Materiales , Análisis del Estrés Dental
12.
PeerJ ; 12: e17921, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39210915

RESUMEN

Background: This study aimed to examine the effect of the force applied by rubber dam clamps made from different materials on mandibular first molar teeth with various designs of endodontic access cavities using finite element analysis. Methods: A intact tooth (IT) and seven different endodontic access cavities namely, a traditional endodontic cavity (TRADAC), a guided endodontic cavity (GEC), a conservative endodontic cavity (CAC), an ultra-conservative access cavity (UAC), a truss access endodontic cavity (TRSAC), a mesial caries access cavity (MCAC), and a distal caries access cavity (DCAC), along with two different clamp finite element models, were created. The clamp models were made of polyether ether ketone (PEEK) and stainless steel (SS). The forces applied by the clamps were calculated based on the axial section distance of the tooth, and these forces were applied to the contact areas on the tooth. Stress distribution models were calculated using maximum von Mises (vM) stress. Results: The lowest vM stress under the forces applied by the SS and PEEK clamps was found in the IT model (80.914 MPa) with the PEEK clamp. The highest vM stress was found in the DCAC model (759.49 MPa) applied with the SS clamp. The forces applied by SS clamps resulted in higher vM stress values in every cavity design than those applied by PEEK clamps. Conclusion: PEEK clamps generated less force than SS clamps. However, clinicians should follow various isolation strategies (clamp made of different materials, split dam, etc.) according to different cavity types of the tooth.


Asunto(s)
Análisis de Elementos Finitos , Mandíbula , Diente Molar , Dique de Goma , Humanos , Estrés Mecánico , Benzofenonas , Cetonas/química , Análisis del Estrés Dental/métodos , Cavidad Pulpar , Acero Inoxidable/química , Polietilenglicoles/química , Polímeros/química
13.
BMC Oral Health ; 24(1): 997, 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39182086

RESUMEN

OBJECTIVES: To investigate the effect of neutral 10-methacryloyloxydecyl dihydrogen phosphate salt (MDP-Na) on the dentin bond strength and remineralization potential of etch-&-rinse adhesive. METHODS: Two experimental etch-&-rinse adhesives were formulated by incorporating 0 wt% (E0) or 20 wt% (E20) neutral MDP-Na into a basic primer. A commercial adhesive, Adper Single Bond 2 (SB, 3 M ESPE), served as the control. Sixty prepared teeth were randomly allocated into three groups (n = 20) and bonded using either one of the experimental adhesives or SB. Following 24 h of water storage, the bonded specimens were sectioned into resin-dentin sticks, with four resin-dentin sticks obtained from each tooth for microtensile bond strength (MTBS) test. Half of the sticks from each group were immediately subjected to tensile loading using a microtensile tester at a crosshead speed of 1 mm/min, while the other half underwent tensile loading after 6-month incubation in artificial saliva (AS). The degree of conversion (DC) of both the control and experimental adhesives (n = 6 in each group) and the adsorption properties of MDP-Na on the dentin organic matrix (n = 5 in each group) were determined using Fourier-transform infrared spectrometry. Furthermore, the effectiveness of neutral MDP-Na in promoting the mineralization of two-dimensional collagen fibrils and the adhesive-dentin interface was explored using transmission electron microscopy and selected-area electron diffraction. Two- and one-way ANOVA was employed to assess the impact of adhesive type and water storage on dentin bond strength and the DC (α = 0.05). RESULTS: The addition of MDP-Na into the primer increased both the short- and long-term MTBS of the experimental adhesives (p = 0.00). No difference was noted in the DC between the control, E0 and E20 groups (p = 0.366). The MDP-Na remained absorbed on the demineralized dentin even after thorough rinsing. The intra- and extra-fibrillar mineralization of the two-dimensional collagen fibril and dentin bond hybrid layer was confirmed by transmission electron microscopy and selected-area electron diffraction when the primer was added with MDP-Na. CONCLUSIONS: The use of neutral MDP-Na results in high-quality hybrid layer that increase the dentin bond strength of etch-&-rinse adhesive and provides the adhesive with remineralizing capability. This approach may represent a suitable bonding strategy for improving the dentin bond strength and durability of etch-&-rinse adhesive.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Dentina , Metacrilatos , Resistencia a la Tracción , Metacrilatos/química , Humanos , Recubrimiento Dental Adhesivo/métodos , Dentina/ultraestructura , Dentina/efectos de los fármacos , Recubrimientos Dentinarios/química , Remineralización Dental/métodos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Grabado Ácido Dental/métodos , Análisis del Estrés Dental , Técnicas In Vitro , Cementos de Resina/química , Espectroscopía Infrarroja por Transformada de Fourier , Cementos Dentales/química , Propiedades de Superficie
14.
Med Sci Monit ; 30: e945243, 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39182170

RESUMEN

BACKGROUND This study investigates the effect of artificial aging of direct resin nanohybrid composites on mean bond strength values for veneer ceramic samples. MATERIAL AND METHODS Ninety direct nanohybrid composite resin (Tetric N-Ceram) cylindrical discs were divided into 5 groups (n=18 each) based on aging cycles (thermocycling), as follows: TC=no aging (control), T1=850, T3=2500, T6=5000, and T12=10000 cycles, representing 1, 3, 6, and 12 months of clinical usage, respectively. Lithium disilicate glass ceramic (IPS e.max Press) cylindrical discs were cemented to resin discs using resin cement (Variolink N) after surface treatments (ceramic etching, silaning, composite abrasion). Differences in means between subgroups were calculated using one-way ANOVA, followed by the Tukey honestly significant differences post hoc test. Differences were considered statistically significant with a P value ≤0.05. RESULTS The highest SBS between ceramic and aged composite was observed at 1 month (m=20.35) but did not differ significantly from the control group (m=20.97). For all other subgroups (3, 6, 12 months) SBS was significantly less than that of the control (P≤0.05). At 1 and 3 months, cohesive failures were more common, whereas adhesive failures were more common in 6- and 12-month-old composites. CONCLUSIONS SBS of aged composites was less than that of non-aged composites, with SBS decreasing proportionally as the resin aged. When cementing a ceramic restoration over existing composite restorations, those older than 1 month should be removed and replaced with new ones.


Asunto(s)
Cerámica , Resinas Compuestas , Recubrimiento Dental Adhesivo , Coronas con Frente Estético , Ensayo de Materiales , Cerámica/química , Resinas Compuestas/química , Ensayo de Materiales/métodos , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Porcelana Dental/química , Humanos , Análisis del Estrés Dental , Propiedades de Superficie
15.
BMC Oral Health ; 24(1): 1000, 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39183299

RESUMEN

BACKGROUND: Digitally fabricated dentures may require relining due to continual alveolar ridge resorption. However, studies evaluating the tensile bond strength (TBS) of digitally fabricated dentures bonded to denture liners are lacking. This study aimed to evaluate the TBS of autopolymerized, heat-polymerized, milled, and 3D printed denture base materials bonded to 2 acrylic-based and 2 silicone-based denture liners, both before and after thermocycling. Additionally, the impact of thermocycling on the TBS were also evaluated. METHODS: The TBS of 4 different denture base materials (Palapress (PL), Vertex Rapid Simplified (VR), Smile CAM total prosthesis (SC), and NextDent denture 3D+ (ND)) bonded to 2 acrylic-based (GC Soft-Liner (GC) and Tokuyama Rebase II (RB)) and 2 silicone-based (Ufi Gel P (UP) and Sofreliner Tough M (ST)) denture liners were tested. Specimens (n = 8) were divided into non-thermocycling and thermocycling groups. Non-thermocycling specimens were tested after 24-hours water immersion, while thermocycling specimens were underwent 5000 cycle and were immediately tested. Mode of failure was examined under a stereomicroscope. Data were analyzed using 2-way ANOVA and Tukey HSD tests (α = 0.05), and independent samples t test (α = 0.05) for TBS between non-thermocycling and thermocycling groups. RESULTS: For the non-thermocycling groups, within the same denture liner material, no significant differences were found between denture base materials, except the ND + RB group, which had significantly lower TBS. For the thermocycling groups, within the same denture liner material, the TBS in the PL group exhibited the highest and the ND group exhibited the lowest. Within the same denture base material, in both non-thermocycling and thermocycling groups, the TBS in the ST group exhibited the highest; in contrast, that in the GC group exhibited the lowest. No significant differences were observed in TBS between non-thermocycling and thermocycling groups, except for denture base materials bonded to the ST group, SC + UP, and ND + UP groups. CONCLUSIONS: Milled denture base can be relined with acrylic-based or silicone-based denture liner. However, cautions should be exercised when relining 3D printed denture base. Thermocycling did not affect TBS between acrylic-based denture liners and denture bases. In contrast, it affected the bond between silicone-based denture liner and denture base.


Asunto(s)
Bases para Dentadura , Alineadores Dentales , Ensayo de Materiales , Impresión Tridimensional , Resistencia a la Tracción , Resinas Acrílicas/química , Recubrimiento Dental Adhesivo/métodos , Humanos , Polimerizacion , Materiales Dentales/química , Técnicas In Vitro , Calor , Análisis del Estrés Dental , Polimetil Metacrilato/química , Siliconas/química , Elastómeros de Silicona/química
16.
BMC Oral Health ; 24(1): 901, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107754

RESUMEN

BACKGROUND: Mechanical complications affect the stability of implant restorations and are a key concern for clinicians, especially with the frequent introduction of new implant designs featuring various structures and materials. This study evaluated the effect of different prosthetic index structure types and implant materials on the stress distribution of implant restorations using both in silico and in vitro methods. METHODS: Four finite element analysis (FEA) models of implant restorations were created, incorporating two prosthetic index structures (cross-fit (CF) and torc-fit (TF)) and two implant materials (titanium and titanium-zirconium). A static load was applied to each group. An in vitro study using digital image correlation (DIC) with a research scenario identical to that of the FEA was conducted for validation. The primary strain, sensitivity index, and equivalent von Mises stress were used to evaluate the outcomes. RESULTS: Changing the implant material from titanium to titanium-zirconium did not significantly affect the stress distribution or maximum stress value of other components, except for the implant itself. In the CF group, implants with a lower elastic modulus increased the stress on the screw. The TF group showed better stress distribution on the abutment and a lower stress value on the screw. The TF group demonstrated similar sensitivity for all components. DIC analysis revealed significant differences between TF-TiZr and CF-Ti in terms of the maximum (P < 0.001) and minimum principal strains (P < 0.05) on the implants and the minimum principal strains on the investment materials in both groups (P < 0.001). CONCLUSIONS: Changes in the implant material significantly affected the maximum stress of the implant. The TF group exhibited better structural integrity and reliability.


Asunto(s)
Implantes Dentales , Materiales Dentales , Análisis del Estrés Dental , Análisis de Elementos Finitos , Titanio , Circonio , Circonio/química , Humanos , Materiales Dentales/química , Análisis del Estrés Dental/métodos , Estrés Mecánico , Diseño de Prótesis Dental , Módulo de Elasticidad , Simulación por Computador , Imagenología Tridimensional
17.
J Prosthodont ; 33(7): 684-690, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39118597

RESUMEN

PURPOSE: This in vitro study aimed to create a graded structured dental crown using 3D printing technology and investigate the fracture resistance and the adaptation of this new design. MATERIALS AND METHODS: A dental crown with a uniform thickness of 1.5 mm was designed, and the exported stereolithography file (STL) was used to manufacture 30 crowns in three groups (n = 10), solid (SC), bilayer (BL), and multilayer (ML) crowns using  3D jet printing technology. Marginal and internal gaps were measured using the silicone replica technique. Crowns were then luted to a resin die using a temporary luting agent and the fracture resistance was measured using a universal testing machine. One-way ANOVA and Tukey post hoc tests were used to compare the fracture resistance and the adaptation of crowns at a significance level of 0.05. RESULTS: Mean marginal and internal gap of the ML group were 80 and 82 mm, respectively; which were significantly (p < 0.05) smaller than BL (203 and 183 mm) and SC (318 and 221 mm) groups. The SC group showed the highest mean load at fracture (2330 N) which was significantly (p < 0.05) higher than the BL (1716 N) and ML (1516 N) groups. CONCLUSION: 3D jet printing technology provides an opportunity to manufacture crowns in a graded structure with various mechanical properties. This study provided an example of graded structured crowns and presented their fracture resistance. SC group had the highest fracture resistance; however, ML had the best marginal and internal adaptation.


Asunto(s)
Coronas , Diseño de Prótesis Dental , Análisis del Estrés Dental , Impresión Tridimensional , Diseño de Prótesis Dental/métodos , Humanos , Adaptación Marginal Dental , Ensayo de Materiales , Fracaso de la Restauración Dental , Técnicas In Vitro , Diseño Asistido por Computadora
18.
BMC Oral Health ; 24(1): 913, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39118080

RESUMEN

OBJECTIVES: This study aimed to evaluate the feasibility of monolithic zirconia laminate veneers (MZLV) compared to lithium disilicate laminate veneers (LDLV). MATERIALS AND METHODS: Sixty resin replicas, each prepared with depths of 0.5 mm, 0.7 mm, and 1 mm, were produced using a 3D printer from acrylic teeth. Laminate veneers of these thicknesses were milled from pre-sintered monolithic zirconia (3rd generation) and lithium disilicate blocks. The intaglio surface of MZLV was treated with air abrasion using 110 µm diameter silica-modified aluminium oxide particles and ceramic primer, while LDLV was etched with etchant gel and treated with the ceramic primer before cementation with resin cement. Vertical marginal discrepancy (VMD) was assessed using a stereomicroscope, and a load-to-failure test was conducted using a universal testing machine. Failure modes were evaluated macroscopically on fractured surfaces. Data were analysed statistically using Two-way ANOVA and Bonferroni correction (α = 0.05). RESULTS: LDLV samples exhibited significantly larger VMD compared to MZLV samples across all thicknesses, especially in cervical, palatal, and mean data. Within the LDLV group, load-to-fracture values for 0.7 mm and 1.0 mm thicknesses were similar, whereas for 0.5 mm thickness, it was significantly lower. In the MZLV group, load-to-fracture values were lower for 0.7 mm and 1.0 mm thicknesses compared to LDLV, but higher for 0.5 mm thickness. CONCLUSIONS: Material choice and restoration thickness significantly influence laminate veneer restorations' success. MZLV generally exhibits superior vertical marginal fit compared to LDLV, with varying load-to-failure values across different thicknesses. Clinical management of debonding in MZLV is simpler compared to restoration fracture in LDLV. CLINICAL RELEVANCE: Considering clinical factors, MZLV may be a preferable option to LDLV for this restoration with the thickness of 0.5 mm.


Asunto(s)
Adaptación Marginal Dental , Porcelana Dental , Coronas con Frente Estético , Circonio , Porcelana Dental/química , Circonio/química , Humanos , Ensayo de Materiales , Análisis del Estrés Dental , Fracaso de la Restauración Dental , Propiedades de Superficie , Materiales Dentales/química , Diseño de Prótesis Dental
19.
Clin Oral Investig ; 28(8): 465, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39098966

RESUMEN

OBJECTIVE: To evaluate the effect of four different photoactivation protocols (according to "photoactivated faces" - mesial/distal, cervical/incisal or center - and "photoactivation time" - 6-3 s) of a high-power photo activator (Valo Cordless®-Ultradent) on the shear bond strength (SBS) between metal brackets and dental enamel and on the degree of conversion (DC) of an orthodontic resin. MATERIALS AND METHODS: 40 bovine incisor crowns were randomly assigned to 4 groups (n = 10). The brackets were bonded with Transbond XT® resin using 4 protocols according to the "photoactivation protocol" factor (which was subdivided into photoactivated faces and photoactivation time): V3C = 3 s + center; V6C = 6 s + center; V3M3D = 3 s on mesial + 3 s on distal; V3C3I = 3 s on cervical + 3 s on incisal. All the samples were stored for 4 months (water,37ºC) and then subjected to a SBS test (100KgF,1 mm/min). 40 resin discs were made to evaluate the monomer degree of conversion. Data from the SBS and DC were assessed by One-way ANOVA and Tukey's test (5%). Bond failures were analyzed according to the Adhesive Remnant Index (ARI) and evaluated by the Kruskal-Wallis test (5%). RESULTS: There was a statistically significant difference (p = 0.008) in the One-way ANOVA result for SBS values between all groups, but the protocols showed statistically similar results (p ≥ 0.05-Tukey's tests) concerning the photoactivated faces (V6C, V3M3D and V3C3I) and photoactivation time (V3C and V6C) factors individually. There was no statistically significant difference (p ≥ 0.05) in the One-way ANOVA result for DC values. CONCLUSION: The SBS and DC values will vary depending on the protocol applied. CLINICAL RELEVANCE: It is possible to maintain the bracket fixation quality with the use of a high-power LED photo activator associated with a shorter photoactivation time. However, it is assumed that not all types of protocols that might be applied will provide quality bonding, such as V3C, V3M3D and V3C3I, which may - depending on the SBS and DC values - affect the final treatment time, due to brackets debonding, or increase of possibility of damage to dental enamel during bracket removal. Clinical studies are suggested to confirm the hypotheses of this research.


Asunto(s)
Recubrimiento Dental Adhesivo , Esmalte Dental , Análisis del Estrés Dental , Ensayo de Materiales , Soportes Ortodóncicos , Distribución Aleatoria , Cementos de Resina , Resistencia al Corte , Animales , Bovinos , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Esmalte Dental/química , Propiedades de Superficie , Técnicas In Vitro , Factores de Tiempo , Corona del Diente , Polimerizacion
20.
Clin Oral Investig ; 28(9): 468, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39105859

RESUMEN

OBJECTIVE: this study aimed to digitally compare wear behavior and retention between PEEK and nylon retentive inserts used in locator-retained, mandibular implant overdentures when attachment design and size were standardized. MATERIALS AND METHODS: A total of sixty-four inserts (32 PEEK and 32 nylon inserts); were picked-up in implant overdentures. Overdentures of both groups were submerged in artificial saliva and mounted to chewing simulator. After 480,000 chewing cycles (equivalent to 2 years of clinical use) all inserts were scanned by scanning electron microscope (SEM), then all acquired images were digitally analyzed by software to detect and compare quantitative and qualitative changes of inserts in both groups. On the other hand, retention of both groups was measured by universal testing machine and the collected data was statistically analyzed using one-way Analysis of Variance (ANOVA) test with significance level set at P ≤ 0.05. RESULTS: PEEK inserts showed significantly higher mean retentive values compared to the nylon inserts in the control group. Also, PEEK retentive inserts exhibited statistically lower mean wear values than the control group P ≥ 0.000. Qualitative investigation revealed significant and more pronounced changes in the surface roughness of nylon inserts compared to PEEK ones. CONCLUSIONS: Regarding retention, wear behavior and dimension stability, PEEK can be recommended as retentive insert material in cases of locator-retained mandibular implant overdentures. CLINICAL RELEVANCE: PEEK inserts offer enhanced retention, reduced wear, and greater dimensional stability over two years time interval. Clinically, this reduces prosthodontic maintenance and adjustments, improving patient satisfaction and long-term prosthetic success.


Asunto(s)
Benzofenonas , Prótesis Dental de Soporte Implantado , Retención de Dentadura , Prótesis de Recubrimiento , Cetonas , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Nylons , Polietilenglicoles , Polímeros , Propiedades de Superficie , Cetonas/química , Polietilenglicoles/química , Humanos , Técnicas In Vitro , Mandíbula , Alisadura de la Restauración Dental , Diseño de Dentadura , Análisis del Estrés Dental , Saliva Artificial