1.
Phys Med Biol ; 69(18)2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39241801

RESUMEN

Objective.Newer generation linear accelerators (Linacs) allow 20 s cone-beam CT (CBCT) acquisition which reduces radiation therapy treatment time. However, the current clinical application of these rapid scans is only 3DCBCT. In this paper we propose a novel data-driven rapid 4DCBCT reconstruction method for new generation linacs.Approach.This method relies on estimating the magnitude of the diaphragm motion from an initial 3D reconstruction. This estimated motion is used to linearly approximate a deformation vector field (DVF) for each respiration phase. These DVFs are then used for motion compensated Feldkamp-Davis-Kress (MCFDK) reconstructions. This method, named MCFDK Data Driven (MCFDK-DD), was compared to a MCFDK reconstruction using a prior motion model (MCFDK-Prior), a 3D-FDK reconstruction, and a conventional acquisition (4 mins) conventional reconstruction 4DCBCT (4D-FDK). The data used in this paper were derived from 4DCT volumes from 12 patients from The Cancer Imaging Archives. Image quality was quantified using RMSE of line plots centred on the tumour, tissue interface width (TIW), the mean square error (MSE) and structural similarity index measurement (SSIM).Main Results.The tumour line plots in the Superior-Inferior direction showed reduced RMSE for the MCFDK-DD compared to the 3D-FDK method, indicating the MCFDK-DD method provided a more accurate tumour location. Similarly, the TIW values from the MCFDK-DD reconstructions (median 8.6 mm) were significantly reduced for the MCFDK-DD method compared to the 3D-FDK reconstructions (median 14.8 mm, (p< 0.001). The MCFDK-DD, MCFDK-Prior and 3D-FDK had median MSE values of1.08×10-6mm-1,1.11×10-6mm-1and1.17×10-6mm-1respectively. The corresponding median SSIM values were 0.93, 0.92 and 0.92 respectively indicating the MCFDK-DD had good agreement with the conventional 4D-FDK reconstructions.Significance.These results demonstrate the feasibility of creating accurate data-driven 4DCBCT images for rapid scans on new generation linacs. These findings could lead to increased clinical usage of 4D information on newer generation linacs.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada Cuatridimensional , Aceleradores de Partículas , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Cuatridimensional/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Factores de Tiempo , Respiración , Movimiento
2.
Biomed Phys Eng Express ; 10(5)2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39151446

RESUMEN

This study aims to evaluate the optical response dependence of the PAKAG polymer gel dosimeter on photon energy and dose rate. The produced gel dosimeters were irradiated using a Varian CL 21EX medical linear accelerator with delivered doses of 0, 2, 4, 6, 8, and 10 Gy. To examine the response dependence on the delivered dose rate, dose rates of 50, 100, 200, and 350 cGy min-1were investigated. Additionally, two incident beam qualities of 6 and 18 MV were examined to study the response dependence on the incident beam energy. The irradiated polymer gel dosimeters were readout using a UV-vis spectrophotometer in the 300 to 800 nm scan range. The results reveal that a wide variation in dose rate (50-350 cGy.min-1) influences the absorbance-dose response and the sensitivity of PAKAG gel. However, smaller variations did not show a significant effect on the response. Furthermore, the response changed insignificantly with beam quality for investigated energies. It was concluded that the optical reading response of the PAKAG polymer gel dosimeter is satisfactorily independent of external parameters, including dose rate and incident beam quality.


Asunto(s)
Geles , Polímeros , Dosímetros de Radiación , Polímeros/química , Geles/química , Radiometría/métodos , Radiometría/instrumentación , Fotones , Aceleradores de Partículas/instrumentación , Humanos , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo
3.
Med Eng Phys ; 130: 104217, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-39160023

RESUMEN

Stereotactic Radiosurgery (SRS) for brain tumors using Medical Linear Accelerator (LINAC) demands high precision and accuracy. A specific Quality Assurance (QA) is essential for every patient undergoing SRS to protect nearby non-cancerous cells by ensuring that the X-ray beams are targeted according to tumor position. In this work, a water-filled generic anthropomorphic head phantom consisting of two removable parts with eccentric holes was developed using Additive Manufacturing (AM) process for performing QA in SRS. In the patient specific QA, the planned radiation dose using Treatment Planning System (TPS) was compared with the dose measured in the phantom. Also, the energy consistency of radiation beams was tested at 200 MU for different energy beams at the central and eccentric holes of the phantom using an ionization chamber. Experimentally examined results show that planned doses in TPS are reaching the target within a 5% deviation. The ratio of the dose delivered in the eccentric hole to the dose delivered to the central hole shows variations of less than 2% for the energy consistency test. The designed, low-cost water-filled anthropomorphic phantom is observed to improve positioning verification and accurate dosimetry of patient-specific QA in SRS treatment.


Asunto(s)
Cabeza , Aceleradores de Partículas , Fantasmas de Imagen , Impresión Tridimensional , Radiocirugia , Radiocirugia/instrumentación , Humanos , Garantía de la Calidad de Atención de Salud , Planificación de la Radioterapia Asistida por Computador , Control de Calidad , Dosificación Radioterapéutica
4.
Biomed Phys Eng Express ; 10(5)2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39142300

RESUMEN

Objective. This study aims to design and fabricate a 3D printed heterogeneous paediatric head phantom and to customize a thorax phantom for radiotherapy dosimetry.Approach. This study designed, fabricated, and tested 3D printed radiotherapy phantoms that can simulate soft tissue, lung, brain, and bone. Various polymers were considered in designing the phantoms. Polylactic acid+, nylon, and plaster were used in simulating different tissue equivalence. Dimensional accuracy, and CT number were investigated. The phantoms were subjected to a complete radiotherapy clinical workflow. Several treatment plans were delivered in both the head and the thorax phantom from a simple single 6 MV beam, parallel opposed beams, and five-field intensity modulated radiotherapy (IMRT) beams. Dose measurements using an ionization chamber and radiochromic films were compared with the calculated doses of the Varian Eclipse treatment planning system (TPS).Main results. The fabricated heterogeneous phantoms represent paediatric human head and adult thorax based on its radiation attenuation and anatomy. The measured CT number ranges are within -786.23 ± 10.55, 0.98 ± 3.86, 129.51 ± 12.83, and 651.14 ± 47.76 HU for lung, water/brain, soft tissue, and bone, respectively. It has a good radiological imaging visual similarity relative to a real human head and thorax depicting soft tissue, lung, bone, and brain. The accumulated dose readings for both conformal radiotherapy and IMRT match with the TPS calculated dose within ±2% and ±4% for head and thorax phantom, respectively. The mean pass rate for all the plans delivered are above 90% for gamma analysis criterion of 3%/3 mm.Significance and conclusion. The fabricated heterogeneous paediatric head and thorax phantoms are useful in Linac end-to-end radiotherapy quality assurance based on its CT image and measured radiation dose. The manufacturing and dosimetry workflow of this study can be utilized by other institutions for dosimetry and trainings.


Asunto(s)
Cabeza , Aceleradores de Partículas , Fantasmas de Imagen , Impresión Tridimensional , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Tórax , Humanos , Tórax/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Niño , Aceleradores de Partículas/instrumentación , Adulto , Garantía de la Calidad de Atención de Salud , Radiometría/métodos , Tomografía Computarizada por Rayos X
5.
Biomed Phys Eng Express ; 10(5)2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39151448

RESUMEN

Purpose. This work investigates the small-field dosimetric characteristics of a 2.5 MV sintered diamond target beam and its feasibility for use in linac-based intracranial stereotactic treatments. Due to the increased proportion of low energy photons in the low-Z beam, it was hypothesized that this novel beam would provide sharper dose fall-off compared to the 6 MV beam owing to the reduced energy, and therefore range, of secondary electrons.Methods. Stereotactic treatments of ocular melanoma and trigeminal neuralgia were simulated for 2.5 MV low-Z and 6 MV beams using Monte Carlo to calculate dose in a voxelized anatomical phantom. Two collimation methods were investigated, including a 5 × 3 mm2HDMLC field and a 4 mm cone to demonstrate isolated and combined effects of geometric and radiological contributions to the penumbral width.Results. The measured 2.5 MV low-Z dosimetric profiles demonstrated reduced penumbra by 0.5 mm in both the inline and crossline directions across all depths for both collimation methods, compared to 6 MV. In both treatment cases, the 2.5 MV low-Z beam collimated with the 4 mm cone produced the sharpest dose fall off in profiles captured through isocenter. This improved fall-off resulted in a 59% decrease to the maximum brainstem dose in the trigeminal neuralgia case for the 2.5 MV low-Z MLC collimated beam compared to 6 MV. Reductions to the maximum and mean doses to ipsilateral and contralateral OARs in the ocular melanoma case were observed for the 2.5 MV low-Z beam compared to 6 MV with both collimation methods.Conclusions. While the low dose rate of this novel beam prohibits immediate clinical translation, the results of this study support the further development of this prototype beam to decrease toxicity in intracranial SRS treatments.


Asunto(s)
Diamante , Melanoma , Método de Montecarlo , Aceleradores de Partículas , Fantasmas de Imagen , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neuralgia del Trigémino , Humanos , Radiocirugia/métodos , Melanoma/radioterapia , Neuralgia del Trigémino/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos , Fotones , Neoplasias del Ojo/radioterapia , Electrones/uso terapéutico
6.
Appl Radiat Isot ; 212: 111458, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39111051

RESUMEN

One important issue in Boron Neutron Capture Therapy is the delivered dose to the tissues outside the tumor. An international standard for light ion beam systems sets two recommended limits for out-of-field dose based on distance from the field edge: maximum absorbed dose from all radiation types shall not exceed 0.5 % of the maximum dose at distances 15 cm to 50 cm from the field edge. At distances >50 cm from the field edge, the maximum absorbed dose shall not exceed 0.1 %. This paper is a continuation of our previous works focused on the design of an accelerator-based neutron source for BNCT. We already designed a novel Beam Shape Assembly which meets the IAEA criteria for BNCT treatments. Using this BSA, in the present work, we characterize by Monte Carlo simulations the dose outside the neutron field. The out-of-field dose has been assessed via estimates using the ambient and equivalent dose. Also the boron uptake in healthy tissues has been analyzed for the equivalent dose computation. It is concluded that our design for a future accelerator-based source for BNCT meets reasonably well the criteria defined from other forms of radiotherapy on both equivalent and effective dose outside the field.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Método de Montecarlo , Aceleradores de Partículas , Dosificación Radioterapéutica , Terapia por Captura de Neutrón de Boro/métodos , Humanos , Neutrones , Simulación por Computador , Radiometría/métodos
7.
Biomed Phys Eng Express ; 10(5)2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39111326

RESUMEN

Purpose. To evaluate the feasibility of use of an 1.5 T magnetic resonance (MR)-linear accelerator MR-linac for imaging in gynaecologic high-dose-rate (HDR) brachytherapy.Method. Commissioning measurements for MR images quality control, geometric distortion, dwell position accuracy, applicator reconstruction and end-to-end test for a tandem-and-ring applicator were performed following the recommendations of American Brachytherapy Society, International Commission on Radiation Units and Measurements and Report of the Brachytherapy Working Group of the Spanish Society of Medical Physics. The values for MR-based IGABT were compared to the corresponding values with computed tomography (CT).Results. Measured distorsions for the MR images were less than 0.50 mm compared to the CT images. The differences between 3D displacements for all dwell positions were 0.66 mm and 0.62 mm for the tandem and ring, respectively. The maximum difference is 0.64 mm for the distances from the applicator tip obtained using the films. The CT and MR dose differences for the right and left 'A' points were 0.9% and -0.7%, respectively. Similar results were observed in terms of dose distribution for CT and Mr The gamma passing rate was 99.3% and 99.5%, respectively.Conclusion. The use of MR images from an MR-linac used in a radiotherapy service for gynaecological brachytherapy was proved to be feasible, safe and precise as the geometrical differences were less than 1 mm, and the dosimetric differences were less than 1% when comparing to the use of CT images for the same purpose.


Asunto(s)
Braquiterapia , Imagen por Resonancia Magnética , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen , Tomografía Computarizada por Rayos X , Braquiterapia/métodos , Humanos , Femenino , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Radioterapia Guiada por Imagen/métodos , Aceleradores de Partículas , Neoplasias de los Genitales Femeninos/radioterapia , Neoplasias de los Genitales Femeninos/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Fantasmas de Imagen , Estudios de Factibilidad
8.
Phys Med Biol ; 69(17)2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39137816

RESUMEN

Objective. In 1.5 T MR-linacs, the absorbed dose central axis (CAX) deviates from the beam's CAX due to inherent profile asymmetry. In addition, a measured CAX deviation may be biased due to potential lateral (to the beam) effective point of measurement (EPOML) shifts of the detector employed. By investigating CAX deviations, the scope of this study is to determine a set ofEPOMLshifts for profile measurements in 1.5 T MR-linacs.Approach. The Semiflex 3D ion chamber and microDiamond detector (PTW, Germany) were considered in the experimental study while three more detectors were included in the Monte Carlo (MC) study. CAX deviations in the crossline and inline profiles were calculated based on inflection points of the 10×10 cm2field, at five centers. In MC simulations, the experimental setup was reproduced. A small water voxel was simulated to calculate CAX deviation without the impact of the detector-specificEPOMLshift.Main results. All measurements were consistent among the five centers. MC-based and experimental measurements were in agreement within uncertainties. Placing the microDiamond in the vertical orientation does not appear to affect the detector'sEPOML, which is on its central longitudinal axis. For the Semiflex 3D in the crossline direction, the CAX deviation was 2.3 mm, i.e. 1 mm larger than the ones measured using the microDiamond and simulated considering the ideal water detector. Thus, anEPOMLshift of 1 mm is recommended for crossline profile measurements under both Semiflex 3D orientations. For the inline profile, anEPOMLshift of -0.5 mm was determined only for the parallel configuration. In the MC study, CAX deviations were found detector- and orientation-dependent. The dead volume is responsible for theEPOMLshift only in the inline profile and under the parallel orientation.Significance. This work contributes to data availability on the correction or mitigation of the magnetic field-induced changes in the detectors' response.


Asunto(s)
Imagen por Resonancia Magnética , Método de Montecarlo , Aceleradores de Partículas , Imagen por Resonancia Magnética/instrumentación , Radiometría/instrumentación , Radiometría/métodos
9.
Phys Med ; 125: 104502, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39216313

RESUMEN

PURPOSE: This study aims to evaluate the positioning correction extracted from Intra-fraction Cone Beam (IF-CBCT) images obtained during Stereotactic Body Radiotherapy (SBRT) treatments, and to assess whether its magnitude justifies its acquisition. In addition, the results obtained in lung, liver, and pancreas SBRTs with two deep inspiration breath-hold systems (DIBH), and for prostate with/without ultrasound (US) monitoring were compared. METHODS: 1449 treatments, performed with two linear accelerators (LINACs) were retrospectively analyzed. DIBH were performed either with a spirometry-based device or a surface-guidance system and one LINAC was equipped with US monitoring system for prostate. Significance tests were used to account for differences between units. RESULTS: Group systematic error (M) was approximately -0.7 mm for DIBH treatments in superior-inferior (SI) direction with no difference (p > 0.7) between LINACs. Moreover, there was a SI difference of 0.5 mm for prostate treatments (p = 0.008), in favor of the US monitored one. In anterior-posterior (AP) direction, only liver treatments exhibited differences between LINACs, with the spirometer-based system being 0.8 mm inferior (p = 0.003). M<0.4 mm in left-right (LR) direction was found for all locations and LINACs. The spirometer-based system resulted in lower standard deviation of systematic and random errors in most components and locations, with a greater effect observed in liver SBRTs. CONCLUSIONS: The corrections made with IF-CBCT during SBRT treatments were not negligible. Both DIBH systems were effective in managing respiratory movements. However, the spirometry-based system was slightly more accurate. In addition, US monitoring of the prostate appeared to be useful in reducing target shift.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Radiocirugia , Humanos , Radiocirugia/métodos , Tomografía Computarizada de Haz Cónico/métodos , Masculino , Estudios Retrospectivos , Posicionamiento del Paciente , Contencion de la Respiración , Fraccionamiento de la Dosis de Radiación , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Aceleradores de Partículas
10.
Biomed Phys Eng Express ; 10(6)2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39191263

RESUMEN

Purpose. Pulsed volumetric modulated arc therapy (VMAT) was proposed as an advanced treatment that combines the biological benefits of pulsed low dose rate (PLDR) and the dosimetric benefits of the intensity-modulated beams. In our conventional pulsed VMAT technique, a daily fractional dose of 200 cGy is delivered in 10 arcs with 3 min intervals between the arcs. In this study, we are testing the feasibility of pulsed VMAT that omits the need to split into ten arcs and excludes any beam-off gaps.Methods. The study was conducted using computed tomographic images of 24 patients previously treated at our institution with the conventional PLDR technique. Our newly installed Elekta machine has a low dose rate option on the order of 25 MU min-1. PLDR requires an effective dose rate of 6.7 cGy min-1with attention being paid to the maximum dose received within any point within the target not to exceed 13 cGy min-1. The quality of treatment plans was judged based on dose-volume histograms, isodose distribution, dose conformality to the target, and target dose homogeneity. The dose delivery accuracy was assessed by measurements using theMatriXXEvolution2D array system.Results. All cases were normalized to cover 95% of the target volume with 100% of the prescription dose. The average conformity index was 1.03 ± 0.08 while the average homogeneity index was 1.05 ± 0.02. The maximum reported dose rate at any point within the target was 10.44 cGy min-1. The mean dose rate for all pulsed VMAT plans was 6.88 ± 0.1 cGy min-1. All cases passed our gamma analysis with an average passing rate of 99.00% ± 0.48%.Conclusion. The study showed the applicability of planning pulsed VMAT using Eclipse and its successful delivery on our Elekta linac. Pulsed VMAT using the machine's low dose rate mode is more efficient than our previous pulsed VMAT delivery.


Asunto(s)
Aceleradores de Partículas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias/radioterapia
11.
In Vivo ; 38(5): 2254-2260, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39187370

RESUMEN

BACKGROUND/AIM: The aim was to assess the complexity of breast volumetric-modulated arc therapy (VMAT) plans using various indices and to evaluate their performance through gamma analysis in predicting plan deliverability. MATERIALS AND METHODS: A total of 285 VMAT plans for 260 patients were created using the VersaHD™ linear accelerator with a Monaco treatment planning system. Corresponding verification plans were generated using the ArcCHECK® detector, and gamma analysis was conducted employing various criteria. Twenty-eight plan complexity metrics were computed, and Pearson's correlation coefficients were determined between the gamma passing rate (GPR) and these metrics. RESULTS: The average GPR values for all plans were 97.7%, 89.9%, and 78.0% for the 2 mm/2%, 1 mm/2%, and 1 mm/1% criteria, respectively. While most complexity metrics exhibited weak correlations with GPRs under the 2 mm/2% criterion, leaf sequence variability (LSV), plan-averaged beam area (PA), converted area metric (CAM), and edge area metric (EAM) demonstrated the most robust performance, with Pearson's correlation coefficients of 0.57, 0.50, -0.70, and -0.56, respectively. CONCLUSION: Metrics related to beam aperture size and irregularity, such as LSV, PA, CAM and EAM, proved to be reasonable predictors of plan deliverability in breast VMAT.


Asunto(s)
Neoplasias de la Mama , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Mama/radioterapia , Femenino , Aceleradores de Partículas/instrumentación , Algoritmos
12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(4): 434-439, 2024 Jul 30.
Artículo en Chino | MEDLINE | ID: mdl-39155259

RESUMEN

This paper describes the design of an innovative linear accelerator image-guided radiosurgery (IGRS) device, which is based on a composite twofold rotary gantry structure. The paper discusses five aspects of the innovative device: its overall composition, the safety net space created by the accelerator radiation head as it rotates around the patient's longitudinal axis, the non-coplanar spherical coverage in the direction of the incidence angle for quasi-4π delivery, the structural features of the composite twofold rotary gantry, and the processes of treatment planning and implementation. It elaborates on the device's manufacturing feasibility, safety, effectiveness, accuracy, and efficiency. The conclusion is that this innovative device design holds significant development value and market promotion potential.


Asunto(s)
Radiocirugia , Radiocirugia/instrumentación , Aceleradores de Partículas , Humanos , Diseño de Equipo
13.
Phys Med Biol ; 69(16)2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39084661

RESUMEN

Objective. The FLASH effect can potentially be used to improve the therapeutic ratio of radiotherapy (RT) through delivery of Ultra-high-dose-rate (UHDR) irradiation. Research is actively being conducted to translate UHDR-RT and for this purpose the Mobetron is capable of producing electron beams at both UHDR and conventional dose rates for FLASH research and translation. This work presents commissioning of an UHDR Mobetron with end-to-end tests developed for preclinical research.Approach. UHDR electron beams were commissioned with an efficient approach utilizing a 3D-printed water tank and film to fully characterize beam characteristics and dependences on field size, pulse width (PW) and pulse repetition frequency (PRF). This commissioning data was used to implement a beam model using the GAMOS Monte Carlo toolkit for the preclinical research. Then, the workflow for preclinical FLASH irradiation was validated with end-to-end tests delivered to a 3D-printed mouse phantom with internal inhomogeneities.Main results.PDDs, profiles and output factors acquired with radiochromic films were precisely measured, with a PRF that showed little effect on the UHDR beam energy and spatial characteristics. Increasing PW reduced theDmaxand R50by 2.08 mmµs-1and 1.28 mmµs-1respectively. An end-to-end test of the preclinical research workflow showed that both profiles in head-foot and lateral directions were in good agreement with the MC calculations for the heterogeneous 3D printed mouse phantom with Gamma index above 93% for 2 mm/2% criteria, and 99% for 3 mm/3%.Significance. The UHDR Mobetron is a versatile tool for FLASH preclinical research and this comprehensive beam model and workflow was validated to meet the requirements for conducting translational FLASH research.


Asunto(s)
Electrones , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Método de Montecarlo , Dosis de Radiación , Ratones , Animales
14.
J Appl Clin Med Phys ; 25(8): e14450, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39031891

RESUMEN

The purpose of this study is to develop an electronic portal imaging device-based multi-leaf collimator calibration procedure using log files. Picket fence fields with 2-14 mm nominal strip widths were performed and normalized by open field. Normalized pixel intensity profiles along the direction of leaf motion for each leaf pair were taken. Three independent algorithms and an integration method derived from them were developed according to the valley value, valley area, full-width half-maximum (FWHM) of the profile, and the abutment width of the leaf pairs obtained from the log files. Three data processing schemes (Scheme A, Scheme B, and Scheme C) were performed based on different data processing methods. To test the usefulness and robustness of the algorithm, the known leaf position errors along the direction of perpendicular leaf motion via the treatment planning system were introduced in the picket fence field with nominal 5, 8, and 11 mm. Algorithm tests were performed every 2 weeks over 4 months. According to the log files, about 17.628% and 1.060% of the leaves had position errors beyond ± 0.1 and ± 0.2 mm, respectively. The absolute position errors of the algorithm tests for different data schemes were 0.062 ± 0.067 (Scheme A), 0.041 ± 0.045 (Scheme B), and 0.037 ± 0.043 (Scheme C). The absolute position errors of the algorithms developed by Scheme C were 0.054 ± 0.063 (valley depth method), 0.040 ± 0.038 (valley area method), 0.031 ± 0.031 (FWHM method), and 0.021 ± 0.024 (integrated method). For the efficiency and robustness test of the algorithm, the absolute position errors of the integration method of Scheme C were 0.020 ± 0.024 (5 mm), 0.024 ± 0.026 (8 mm), and 0.018 ± 0.024 (11 mm). Different data processing schemes could affect the accuracy of the developed algorithms. The integration method could integrate the benefits of each algorithm, which improved the level of robustness and accuracy of the algorithm. The integration method can perform multi-leaf collimator (MLC) quality assurance with an accuracy of 0.1 mm. This method is simple, effective, robust, quantitative, and can detect a wide range of MLC leaf position errors.


Asunto(s)
Algoritmos , Aceleradores de Partículas , Garantía de la Calidad de Atención de Salud , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Radioterapia de Intensidad Modulada/métodos , Garantía de la Calidad de Atención de Salud/normas , Aceleradores de Partículas/instrumentación , Calibración , Neoplasias/radioterapia
15.
Phys Med ; 124: 103424, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39002424

RESUMEN

The dosimetric output of a 6FFF beam, produced from a Varian TrueBeam linac exhibited an unexpected downward trend over time that was contrary to well-established expectations. To elucidate the cause of this uncharacteristic trend, a review of the linac's quality control results over its lifetime was performed, including, constancy checks of the dosimetric output, beam energy, flatness and symmetry, and percentage depth dose characteristics. These results were supplemented with a comprehensive series of measurements including flatness and symmetry measurements with a 1D-diode array, high-resolution measurements of the photon beam's build-up region with a parallel-plate chamber and measurement of the beam's output as a function of the x-ray target position. The review of the linac's QC results and supplemental tests identified no deviations in the linac's performance from its commissioning and baseline measurements. However, the 6FFF beam output exhibited a significant dependence on the target location relative to its default position, increasing by 5.43 % with a 0.5 mm target translation, indicating that target degradation was the cause of the atypical output trend. The change in output behaviour was believed to be the result of primary electrons escaping the degraded target and interacting with the linac's monitor chamber. Replacement of the x-ray target caused the 6FFF output to realign with expected trends. Target degradation was uncovered due to a robust quality control trending database and awareness of typical output behaviour. These results demonstrate the importance of data trending to identify component failure and provide centres with knowledge to recognise this potential fault.


Asunto(s)
Aceleradores de Partículas , Control de Calidad , Radiometría/instrumentación , Fotones
16.
Phys Med Biol ; 69(17)2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39053500

RESUMEN

To ensure the accuracy of radiation delivery to patients in a 1.5 T MRI-linac, the implementation of quality assurance (QA) devices compatible with MR technology is essential. The OCTAVIUS 4D MR, made by PTW (Freiburg, Germany) is designed to ensure consistent and ideal alignment of its detectors with the direction of each beam segment. This study focuses on investigating the fundamental characteristics of the detector response for the OCTAVIUS Detector (OD) 1500 MR and OCTAVIUS 1600 MR when used in the MR-compatible OCTAVIUS 4D. Characteristics examined included short-term reproducibility, dose linearity, field size dependency, monitor unit (MU) rate dependency, dose-per-pulse dependency, and angular dependency. The evaluation of OD 1500 MR also involved measuring 25 clinical treatment plans across diverse target sizes and anatomical sites, including the liver/pancreas, rectum, prostate, lungs, and lymph nodes. One plan was measured with the standard setup and with a 5 cm left offset. The OD 1600 MR was not available for these measurements. The capability of the OD 1500 MR to identify potential errors was assessed by introducing a MU and positional shift within the software. The results demonstrated no significant differences in short-term reproducibility (<0.2%), dose linearity (<1%), field size dependency (<0.7%for field sizes larger than 5 cm × 5 cm), MU rate dependency (<0.8%), dose-per-pulse dependency (<0.4%) and angular dependency (standard deviation<0.5%). All tests of clinical plans were successfully completed. The OD 1500 MR demonstrated compatibility with the standard 95% pass rate when employing a global 3%/3 mm gamma criterion, and a 90% pass rate using a global 2%/2 mm gamma criterion. The detector demonstrated the capacity to measure treatment plans with a 5 cm left offset. With the standard parameters, the gamma test was sensitive to position errors but required an addition tests of mean/median dose or point dose in order to detect small dose difference.


Asunto(s)
Imagen por Resonancia Magnética , Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador , Imagen por Resonancia Magnética/instrumentación , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Control de Calidad , Dosificación Radioterapéutica
17.
J Appl Clin Med Phys ; 25(8): e14451, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38952057

RESUMEN

PURPOSE: This study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems. METHODS AND MATERIALS: We assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film. RESULTS: We observed that the 1 × 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 × 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of ∼1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies. CONCLUSIONS: This study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.


Asunto(s)
Electrones , Plásticos , Conteo por Cintilación , Plásticos/química , Conteo por Cintilación/instrumentación , Conteo por Cintilación/métodos , Humanos , Radiometría/métodos , Radiometría/instrumentación , Dosificación Radioterapéutica , Fantasmas de Imagen , Aceleradores de Partículas/instrumentación
18.
Phys Med Biol ; 69(15)2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38959910

RESUMEN

Objective.To develop and benchmark a novel 3D dose verification technique consisting of polymer gel dosimetry (PGD) with cone-beam-CT (CBCT) readout through a two-institution study. The technique has potential for wide and robust applicability through reliance on CBCT readout.Approach. Three treatment plans (3-field, TG119-C-shape spine, 4-target SRS) were created by two independent institutions (Institutions A and B). A Varian Truebeam linear accelerator was used to deliver the plans to NIPAM polymer gel dosimeters produced at both institutions using an identical approach. For readout, a slow CBCT scan mode was used to acquire pre- and post-irradiation images of the gel (1 mm slice thickness). Independent gel analysis tools were used to process the PGD images (A: VistaAce software, B: in-house MATLAB code). Comparing planned and measured doses, the analysis involved a combination of 1D line profiles, 2D contour plots, and 3D global gamma maps (criteria ranging between 2%1 mm and 5%2 mm, with a 10% dose threshold).Main results. For all gamma criteria tested, the 3D gamma pass rates were all above 90% for 3-field and 88% for the SRS plan. For the C-shape spine plan, we benchmarked our 2% 2 mm result against previously published work using film analysis (93.4%). For 2%2 mm, 99.4% (Institution A data), and 89.7% (Institution B data) were obtained based on VistaAce software analysis, 83.7% (Institution A data), and 82.9% (Institution B data) based on MATLAB.Significance. The benchmark data demonstrate that when two institutions follow the same rigorous procedures gamma passing rates up to 99%, for 2%2 mm criteria can be achieved for substantively different treatment plans. The use of different software and calibration techniques may have contributed to the variation in the 3D gamma results. By sharing the data across institutions, we observe the gamma passing rate is more consistent within each pipeline, indicating the need for standardized analysis methods.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Aceleradores de Partículas , Radiometría , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada de Haz Cónico/métodos , Radiometría/métodos , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Imagenología Tridimensional/métodos , Polímeros/química
19.
Asian Pac J Cancer Prev ; 25(6): 2105-2112, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38918673

RESUMEN

PURPOSE: The aim of this study was to investigate the detector size effect on small-field dosimetry and compare the performance of 6MV WFF/FFF techniques. METHODS: We investigated the detector size effect on small-field dosimetry and compared the performance of 6MV WFF/FFF techniques. PDD, profile curves, and absorbed dose were measured in water under reference conditions with 6MV (WFF/FFF) techniques. We employed Farmer FC65-P, CC13, CC01, and IBA Razor diode, with Versa Lineac. Subsequently, we replicated this assessment for small-fields under 5cmx5cm dimensions. RESULTS: For both 6MV WFF/FFF, significant dose differences (Dmax=1.47cm), were ±4.55%, ±6.7, ±12.75% and ±33.3% for 4cmx4cm, 3cmx3cm, 2cmx2cm, and 1cmx1cm, respectively. The average difference relative to D10 was observed to be ±4.66%, ±5.73%, ±6.58%, and ±8.75% for the previous field sizes. Differences between WFF/FFF are neglected values at all field sizes>2.3%, also, the output of the largest detector FC65-P is lower at 55% in the smallest field size. Variation in the profile doesn't exceed a difference of >5% in flatness between WFF/FFF at depth10cm, across all fields, while symmetry is >1%, but radiation output is considerably lower at 55% for FC65-P chamber in 2cmx2cm, 1cmx1cm compared to the CC01 chamber and Razor diode. Significant differences in 1cmx1cm, where FC65-P chamber exhibits around 49% difference compared to Razor diode with 6MV (WFF/FFF).  Conclusions: Significant differences were observed in doses with various detectors. Detector-size influences the dose. WFF/FFF techniques show no major differences in small-fields dosimetry. Utilize some situations the advantage of FFF boasting a higher dose rate, consequently reducing treatment time to half.


Asunto(s)
Radiometría , Humanos , Radiometría/métodos , Dosificación Radioterapéutica , Aceleradores de Partículas/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Fantasmas de Imagen
20.
Asian Pac J Cancer Prev ; 25(6): 2177-2184, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38918681

RESUMEN

OBJECTIVE: The goal of this study is to determine the accuracy of the PTW Beamscan program in determining the inflection point from Flattening Filter Free Beam Profile utilizing Multiple Detectors. METHODS: True Beam Linear Accelerator with 6FFF and 10FFF Photon Energies and 10 cm, 15 cm and 20 cm Field Sizes were used for this study. Profile measurements were taken with PTW's 729, 1,500, and 1,600 and the Starcheck system, the Pinpoint 3D with Beamscan system, and Linac's EPID. The first-order derivative was utilized in both the Excel spreadsheet and Beamscan software to analyse raw measured data to locate inflection point and the FWHM was calculated. The accuracy of inflection points and FWHM between the Excel sheet calculation and the software program were investigated. RESULTS: For 10X10 cm2 in the 729 Array, the greatest differences in FWHM were 5.16 mm and 5.04 mm for the X6 FFF and X10 FFF Energies, respectively. The largest difference was 2.26 mm for 1,600 SRS arrays with a 15×15 cm2 field size. The difference in FWHM between Manual and software analysis for 10X10 cm2 and 20X20 cm2 Field Sizes is in decreasing order for detectors from 729, 1,500, 1,600 SRS, Starcheck, Pinpoint 3D, and EPID. In contrast, there is no climbing or declining pattern detected in the difference in Field Width for the 15×15 cm2 Field Size. Similarly, for all detectors except the 1,600 SRS array, the peak of the first-order derivative occurs at the chamber position for a 15X15 cm2 field size. CONCLUSION: The higher resolution of measurement yields more accuracy in inflection point and the FWHM. Irrespective of measurement resolution, the Beamscan software provided the FWHM closer to the respective nominal Field Size. Out of all detectors, results obtained with Excel Starcheck and EPID are good in agreement with values obtained by the software analysis. Thus, it is shown that Beamscan software is so accurate in determining inflection point of a FFF beam profile and used for routine profile analysis.


Asunto(s)
Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador , Programas Informáticos , Aceleradores de Partículas/instrumentación , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Fotones , Dosificación Radioterapéutica , Radiometría/métodos , Radiometría/instrumentación , Algoritmos