ACS Appl Mater Interfaces ; 16(15): 19421-19431, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38568871

RESUMEN

The employment of flexible piezoresistive sensors has sparked growing interest within the realm of wearable electronic devices, specifically in the fields of health detection and e-skin. Nevertheless, the advancement of piezoresistive sensors has been impeded by their limited sensitivity and restricted operating ranges. Consequently, it is imperative to fabricate sensors with heightened sensitivity and expanded operating ranges through the utilization of the appropriate methodologies. In this paper, piezoresistive sensors were fabricated utilizing electrospun polyvinylidene fluoride/polyacrylonitrile/polyethylene-polypropylene glycol multilayer fibrous membranes anchored with polypyrrole granules as the sensing layer, while electrospun thermoplastic polyurethane (TPU) fibers were employed as the flexible substrate. The sensitivity of the sensor is investigated by varying the fiber diameter of the sensing layer. The experimental findings reveal that a concentration of 14 wt % in the spinning solution exhibits high sensitivity (996.7 kPa-1) within a wide working range (0-10 kPa). This is attributed to the favorable diameter of the fibers prepared at this concentration, which facilitates the uniform in situ growth of pyrrole. The highly deformable TPU flexible fibers and multilayer sensing layer structure enable different linear responses across a broad pressure range (0-1 MPa). Furthermore, the sensor demonstrates good cyclic stability and can detect human movements under different pressures. These results suggest that the piezoresistive sensor with a wide operating range and high sensitivity has significant potential for future health monitoring and artificial intelligence applications.

2.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1013499

RESUMEN

@#Objective To explore the reliability and safety of continuous monitoring of vital signs in patients using wireless wearable monitoring devices after video-assisted thoracoscopic surgery (VATS) for lung cancer. Methods The patients undergoing VATS for lung cancer in West China Hospital, Sichuan University from May to August 2023 were prospectively enrolled. Both wireless wearable and traditional wired devices were used to monitor the vital signs of patients after surgery. Spearman correlation analysis, paired sample t test and ratio Bland-Altman method were used to test the correlation, difference and consistency of monitoring data measured by the two devices. The effective monitoring rate of the wireless wearable device within 12 hours was calculated to test the reliability of its continuous monitoring. Results A total of 20 patients were enrolled, including 15 females and 5 males with an average age of 46.20±11.52 years. Data collected by the two monitoring devices were significantly correlated (P<0.001). Respiratory rate and blood oxygen saturation data collected by the two devices showed no statistical difference (P>0.05), while heart rate measured by wireless wearable device was slightly lower (=−0.307±1.073, P<0.001), and the blood pressure (=1.259±5.354, P<0.001) and body temperature(=0.115±0.231, P<0.001) were slightly higher. The mean ratios of heart rate, respiratory rate, blood oxygen saturation, blood pressure and body temperature collected by the two devices were 0.996, 1.004, 1.000, 1.014, and 1.003, respectively. The 95% limits of agreement (LoA) and 95% confidence interval of 95%LoA of each indicator were within the clinically acceptable limit. The effective monitoring rate of each vital signs within 12 hours was above 98%. Conclusion The wireless wearable device has a high accuracy and reliability for continuous monitoring vital signs of patients after VATS for lung cancer, which provides a security guarantee for subsequent large-scale clinical application and further research.

3.
ACS Sens ; 7(3): 816-826, 2022 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-35188381

RESUMEN

Practical application of wearable gas-sensing devices has been greatly inhibited by the poorly sensitive and specific recognition of target gases. Rapid charge transfer caused by rich sensory neurons in the biological olfactory system has inspired the construction of a highly sensitive sensor network with abundant defect sites for adsorption. Herein, for the first time, we demonstrate an in situ formed neuron-mimic gas sensor in a single gas-sensing channel, which is derived from lattice deviation of S atoms in Bi2S3 nanosheets induced by gold quantum dots. Due to the favorable gas adsorption and charge transfer properties arising from S vacancies, the fabricated sensor exhibits a significantly enhanced response value of 5.6-5 ppm NO2, ultrafast response/recovery performance (18 and 338 s), and excellent selectivity. Furthermore, real-time visual detection of target gases has been accomplished by integrating the flexible sensor into a wearable device.


Asunto(s)
Oro , Dispositivos Electrónicos Vestibles , Gases , Neuronas , Azufre
4.
IEEE J Transl Eng Health Med ; 9: 2700306, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33329944

RESUMEN

Objective: To investigate the feasibility of using a wireless wearable device (WD) in differentiated thyroid cancer (DTC) patients undergoing radionuclide therapy with I-131 (RAI) and protected hospitalization, this study compared the measurements of residual radioactivity obtained with those registered by a permanent environmental home device (HD). Methods: Twenty consecutive patients undergoing RAI hospitalized in restricted, controlled areas were enrolled. The patients underwent comprehensive monitoring of vital/nonvital parameters. We obtained 45580± 13 measurements from the WD, detecting the residual radioactivity for each patient during approximately 56 hours of hospitalization, collecting data 53 times per hour. The samples, collected during daily activities, were averaged every two hours, and the results correlated with those from the HD. Bland-Altman analysis was also used to evaluate the agreement between the two techniques. Results: A significant relationship between the WD and HD was observed (r = 0.96, p < 0.0001). Bland-Altman analysis recognized the agreement between measurements by the WD and HD. The mean value at the end of the first day of hospitalization was 80.81 microSv/h and 60.77 microSv/h (p = ns for WD and HD), whereas those at the end of the second day were 47.08 and 24.96 (p = ns). In the generalized linear model (GLM), a similar trend in performance across time was found with the two techniques. Conclusion: This study demonstrates good agreement between the residual radioactivity measures estimated by the WD and HD modalities, rendering them interchangeable. This approach will allow both the optimization of medical staff exposure and safer patient discharge. Abbreviations: wireless device (WD); differentiated thyroid cancer (DTC); radionuclide therapy with I-131 (RAI); home device (HD); generalized linear model (GLM).


Asunto(s)
Radiactividad , Neoplasias de la Tiroides , Dispositivos Electrónicos Vestibles , Estudios de Factibilidad , Humanos , Radioisótopos de Yodo/uso terapéutico , Neoplasias de la Tiroides/radioterapia
5.
J Med Eng Technol ; 42(6): 461-467, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30648454

RESUMEN

Lateral ankle sprain is one of the most common ankle injuries, especially in sports. When not treated properly, chronic ankle instability (CAI) may develop causing recurrent sprains and permanent damage to ankle ligaments. In this study, the design, implementation and validation of a smart wearable device connected to a smartphone application is described. This device can predict and prevent the occurrence of ankle sprain. Prediction of potentially harmful motion is achieved by continuous monitoring of ankle kinematics using inertial motion sensors. Detection of such a motion immediately triggers electrical stimulation of the peroneal muscles causing foot dorsiflexion, and hence prevents potential injury. The proposed device has the advantage of having a very short response time of eight milliseconds which is sufficient to halt the sprain motion. Laboratory validation testing using a custom designed trapdoor showed an accuracy of 96% in detecting and correcting hazardous motion. Furthermore, this device complies well with the design constrains of a wearable device such as small size and low power consumption. It is also low cost and unobtrusive due to the wireless connection between all components. Future work is recommended to test the clinical effectiveness of the proposed device in patients with CAI.


Asunto(s)
Traumatismos del Tobillo/prevención & control , Aparatos Ortopédicos , Esguinces y Distensiones/prevención & control , Dispositivos Electrónicos Vestibles , Fenómenos Biomecánicos , Estimulación Eléctrica , Diseño de Equipo , Aplicaciones Móviles , Monitoreo Ambulatorio/instrumentación , Músculo Esquelético/fisiología , Teléfono Inteligente , Tecnología Inalámbrica/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA