Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Heliyon ; 10(11): e32616, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38961961

RESUMEN

The study aimed to evaluate the impact of varying modulus of elasticity (MOE) values of dental implants on the deformation and von Mises stress distribution in implant systems and peri-implant bone tissues under dynamic cyclic loading. The implant-bone interface was characterised as frictional contact, and the initial stress was induced using the interference fit method to effectively develop a finite element model for an immediately loaded implant-supported denture. Using the Ansys Workbench 2021 R2 software, an analysis was conducted to examine the deformation and von Mises stress experienced by the implant-supported dentures, peri-implant bone tissue, and implants under dynamic loading across three simulated masticatory cycles. These findings were subsequently evaluated through a comparative analysis. The suprastructures showed varying degrees of maximum deformation across zirconia (Zr), titanium (Ti), low-MOE-Ti, and polyetheretherketone (PEEK) implant systems, registering values of 103.1 µm, 125.68 µm, 169.52 µm, and 844.06 µm, respectively. The Zr implant system demonstrated the lowest values for both maximum deformation and von Mises stress (14.96 µm, 86.71 MPa) in cortical bone. As the MOE increased, the maximum deformation in cancellous bone decreased. The PEEK implant system exhibited the highest maximum von Mises stress (59.12 MPa), whereas the Ti implant system exhibited the lowest stress (22.48 MPa). Elevating the MOE resulted in reductions in both maximum deformation and maximum von Mises stress experienced by the implant. Based on this research, adjusting the MOE of the implant emerged as a viable approach to effectively modify the biomechanical characteristics of the implant system. The Zr implant system demonstrated the least maximum von Mises stress and deformation, presenting a more favourable quality for preserving the stability of the implant-bone interface under immediate loading.

2.
Polymers (Basel) ; 16(11)2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38891432

RESUMEN

The ability of wood-plastic composites (WPCs) to withstand various loads and resist plastic failure is attracting more and more interest due to the global increase in demand for WPCs by over 6 million tons per year. Among the most important and innovative research methods are those based on fracture mechanics-their results enable material designers to optimize the structures of these hybrid polymer composites at the nano, micro and macro levels, and they allow engineers to more accurately evaluate and select functional, sustainable, long-lasting and safe product designs. In this study, standard single-edge notched bending (SENB) tests were used to analyze the fracture toughness of two different extruded WPCs along the longitudinal (L) and transverse (T) directions of extrusion. In addition to their resistance to crack propagation, critical fracture criteria, initial contact stiffness, fracture parameters and fracture surfaces, the mechanical properties of these composites were also investigated. The results showed that WPC-A coded composites withstood higher loads until failure in both directions compared to WPC-B. Despite the larger data spread, both types of composites were more resistant to crack propagation in the T direction. Mode II of crack propagation was clearly visible, while mode III was not as pronounced. The experimental results and the numerical finite element (FE) model developed up to 58% of the maximum load correlated well, and the obtained deformation curves were best approximated using cubic equations (R2 > 0.99). The shear stress zone and its location, as well as the distribution of the equivalent stresses, had a major influence on crack propagation in the fracture process zone (FZP).

3.
BMC Oral Health ; 24(1): 657, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38840138

RESUMEN

BACKGROUND: Margin designs and loading conditions can impact the mechanical characteristics and survival of endocrowns. Analyzing the stress distribution of endocrowns with various margin designs and loading conditions can provide evidence for their clinical application. METHODS: Three finite element analysis models were established based on the margin designs: endocrown with a butt-joint type margin (E0), endocrown with a 90° shoulder (E90), and endocrown with a 135° shoulder (E135). The E0 group involved lowering the occlusal surface and preparing the pulp chamber. The E90 group created a 90° shoulder on the margin of model E0, measuring 1.5 mm high and 1 mm wide. The E135 group featured a 135° shoulder. The solids of the models were in fixed contact with each other, and the materials of tooth tissue and restoration were uniform, continuous, isotropic linear elasticity. Nine static loads were applied, with a total load of 225 N, and the maximum von Mises stresses and stress distribution were calculated for teeth and endocrowns with different margin designs. RESULTS: Compared the stresses of different models under the same loading condition. In endocrowns, when the loading points were concentrated on the buccal side, the maximum von Mises stresses were E0 = E90 = E135, and when there was a lingual loading, they were E0 < E90 = E135. In enamel, the maximum von Mises stresses under all loading conditions were E0 > E90 > E135. In dentin, the maximum von Mises stresses of the three models were basically similar except for load2, load5 and load9. Compare the stresses of the same model under different loading conditions. In endocrowns, stresses were higher when lingual loading was present. In enamel and dentin, stresses were higher when loaded obliquely or unevenly. The stresses in the endocrowns were concentrated in the loading area. In enamel, stress concentration occurred at the cementoenamel junction. In particular, E90 and E135 also experienced stress concentration at the shoulder. In dentin, the stresses were mainly concentrated in the upper section of the tooth root. CONCLUSION: Stress distribution is similar among the three margin designs of endocrowns, but the shoulder-type designs, especially the 135° shoulder, exhibit reduced stress concentration.


Asunto(s)
Análisis del Estrés Dental , Análisis de Elementos Finitos , Estrés Mecánico , Humanos , Análisis del Estrés Dental/métodos , Diseño de Prótesis Dental , Coronas , Fenómenos Biomecánicos , Dentina
4.
Biomed Phys Eng Express ; 10(4)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38806008

RESUMEN

Atherosclerosis is a cardiovascular disease mainly caused by plaque deposition in blood vessels. Plaque comprises components such as thrombosis, fibrin, collagen, and lipid core. It plays an essential role in inducing rupture in a blood vessel. Generally, Plaque could be described as three kinds of elastic models: cellular Plaque, hypocellular Plaque, and calcified Plaque. The present study aimed to investigate the behavior of atherosclerotic plaque rupture according to different lipid cores using Fluid-Structure Interaction (FSI). The blood vessel was also varied with different thicknesses (0.05, 0.25, and 0.5 mm). In this study, FSI simulation with a cellular plaque model with various thicknesses was investigated to obtain information on plaque rupture. Results revealed that the blood vessel with Plaque having a lipid core represents higher stresses than those without a lipid core. Blood vessels' thin thickness, like a thin cap, results in more considerable than Von Mises stress. The result also suggests that even at low fracture stress, the risk of rupture due to platelet decomposition at the gap was more significant for cellular plaques.


Asunto(s)
Simulación por Computador , Enfermedad de la Arteria Coronaria , Modelos Cardiovasculares , Placa Aterosclerótica , Estrés Mecánico , Humanos , Placa Aterosclerótica/patología , Enfermedad de la Arteria Coronaria/patología , Vasos Sanguíneos/patología , Lípidos/química , Vasos Coronarios/patología , Elasticidad
5.
Cureus ; 16(3): e55538, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38576681

RESUMEN

Aim and background This study aims to determine the stress distribution on the prepared tooth at the margins with shoulder and radial shoulder finish lines when an occlusal load of 300N was applied to ceramic, zirconia, and polyether ether ketone (PEEK) crowns. Materials and methods Six models of mandibular first molar teeth were fabricated. The tooth models were subdivided into two groups with shoulder and radial shoulder margins, respectively (n = 18). The teeth were restored with three different prosthetic crown materials (ceramic, zirconia, and PEEK). To simulate the typical forces experienced by a prosthetic crown material in a lower posterior tooth during chewing and biting, an occlusal load of 300N was applied to each of the samples, and the maximum principal stress (Pmax) and von Mises stress were calculated, respectively. These samples were then compared and evaluated to determine the material best suited as a prosthetic crown material of choice for a lower posterior tooth. Results Among the materials used, the maximum principal stress value was the least in PEEK crowns. The von Mises stress value was highest for the zirconia crown with shoulder margin and was least for the PEEK crown with a similar margin. Conclusion PEEK as a crown material was found to be a better choice for lower posterior teeth as there was the least maximum principal stress at the margin, irrespective of either shoulder or radial shoulder finish line used.

6.
J Oral Biol Craniofac Res ; 14(3): 284-289, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38577263

RESUMEN

Aim: To identify the optimal number and position of implants to reduce stress concentration on the implant, denture, and attachment system for sustaining an overdenture prosthesis. Materials and methods: By incorporating one to eight indigenous implants with bar-type attachments, eight 3D finite element models of mandibular overdentures were created. All models received a 200 N vertical load, and the biomechanical characteristics of peri-implant bone were assessed. Result: The study observed that with a vertical load of 200 N, the maximum equivalent stress around peri-implant tissue in all models was within the physiological tolerance threshold of bone. The von Mises stress values ranged from 116.18 MPa to 536.7 MPa. Conclusion: The three-implant-supported overdenture model revealed superior peri-implant stress, stability, cost-effectiveness, and hygiene maintenance outcomes. Placing a third implant in the mid-symphysis region may offer a practical solution to reduce rotations in two-implant-supported overdentures.

7.
BMC Oral Health ; 24(1): 455, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622680

RESUMEN

BACKGROUND: The aim of this study is to evaluate the biomechanical behavior of the mesial and distal off-axial extensions of implant-retained prostheses in the posterior maxilla with different prosthetic materials using finite element analysis (FEA). METHODS: Three dimensional (3D) finite element models with three implant configurations and prosthetic designs (fixed-fixed, mesial cantilever, and distal cantilever) were designed and modelled depending upon cone beam computed tomography (CBCT) images of an intact maxilla of an anonymous patient. Implant prostheses with two materials; Monolithic zirconia (Zr) and polyetherketoneketone (PEKK) were also modeled .The 3D modeling software Mimics Innovation Suite (Mimics 14.0 / 3-matic 7.01; Materialise, Leuven, Belgium) was used. All the models were imported into the FE package Marc/Mentat (ver. 2015; MSC Software, Los Angeles, Calif). Then, individual models were subjected to separate axial loads of 300 N. Von mises stress values were computed for the prostheses, implants, and bone under axial loading. RESULTS: The highest von Mises stresses in implant (111.6 MPa) and bone (100.0 MPa) were recorded in distal cantilever model with PEKK material, while the lowest values in implant (48.9 MPa) and bone (19.6 MPa) were displayed in fixed fixed model with zirconia material. The distal cantilever model with zirconia material yielded the most elevated levels of von Mises stresses within the prosthesis (105 MPa), while the least stresses in prosthesis (35.4 MPa) were recorded in fixed fixed models with PEKK material. CONCLUSIONS: In the light of this study, the combination of fixed fixed implant prosthesis without cantilever using a rigid zirconia material exhibits better biomechanical behavior and stress distribution around bone and implants. As a prosthetic material, low elastic modulus PEKK transmitted more stress to implants and surrounding bone especially with distal cantilever.


Asunto(s)
Implantes Dentales , Circonio , Humanos , Análisis de Elementos Finitos , Maxilar/cirugía , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/métodos , Estrés Mecánico
8.
Biomed Phys Eng Express ; 10(3)2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38437729

RESUMEN

The femur is one of the most important bone in the human body, as it supports the body's weight and helps with movement. The aging global population presents a significant challenge, leading to an increasing demand for artificial joints, particularly in knee and hip replacements, which are among the most prevalent surgical procedures worldwide. This study focuses on hip fractures, a common consequence of osteoporotic fractures in the elderly population. To accurately predict individual bone properties and assess fracture risk, patient-specific finite element models (FEM) were developed using CT data from healthy male individuals. The study employed ANSYS 2023 R2 software to estimate fracture loads under simulated single stance loading conditions, considering strain-based failure criteria. The FEM bone models underwent meticulous reconstruction, incorporating geometrical and mechanical properties crucial for fracture risk assessment. Results revealed an underestimation of the ultimate bearing capacity of bones, indicating potential fractures even during routine activities. The study explored variations in bone density, failure loads, and density/load ratios among different specimens, emphasizing the complexity of bone strength determination. Discussion of findings highlighted discrepancies between simulation results and previous studies, suggesting the need for optimization in modelling approaches. The strain-based yield criterion proved accurate in predicting fracture initiation but required adjustments for better load predictions. The study underscores the importance of refining density-elasticity relationships, investigating boundary conditions, and optimizing models throughin vitrotesting for enhanced clinical applicability in assessing hip fracture risk. In conclusion, this research contributes valuable insights into developing patient-specific FEM bone models for clinical hip fracture risk assessment, emphasizing the need for further refinement and optimization for accurate predictions and enhanced clinical utility.


Asunto(s)
Fracturas de Cadera , Humanos , Masculino , Anciano , Análisis de Elementos Finitos , Densidad Ósea , Fémur , Envejecimiento
9.
J Orthod Sci ; 13: 9, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38516113

RESUMEN

BACKGROUND: To evaluate and compare the distribution of stress and displacement of teeth during mandibular arch distalization using buccal shelf screws. MATERIALS AND METHODS: Three three-dimensional finite element models of mandibular arch were constructed with third molars extracted. Models 1, 2, and 3 were constructed on the basis of the lever arm heights of 0 mm, 3 mm, and 6 mm, respectively, between the lateral incisor and canine. A buccal shelf screw was placed at the area in the second molar region with the initial point of insertion being inter-dental between the first and second molars and 2 mm below the mucogingival junction. MBT pre-adjusted brackets (slot size 0.022 × 0.028") were placed over the clinical crown's center with a 0.019 × 0.025" stainless-steel archwire on three models. A retraction force of 300 g was applied with buccal shelf screws and a lever arm bilaterally using nickel-titanium closed coil springs. The displacement of each tooth was calculated on X, Y, and Z axes, and the von Mises stress distribution was visualized using color-coded scales using ANSYS 12.1 software. RESULT: The maximum von Mises stress in the cortical and cancellous bones was observed in model 1. The maximum von Mises stress in the buccal shelf screw and the cortical bone decreased as the height of the lever arm increased. Applying orthodontic forces at the level of 6 mm lever arm height resulted in greater biomechanical bodily movement in distalization of the mandibular molars compared to when the orthodontic forces were applied at the level of 0 mm lever arm height. CONCLUSION: Displacement of the entire arch may be dictated by a direct relationship between the center of resistance of the whole arch and the line of action generated between the buccal shelf screw and force application points at the archwire, which makes the total arch movement highly predictable.

10.
Proc Inst Mech Eng H ; 238(5): 463-470, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38534009

RESUMEN

The current study aims to comprehend how different bone densities affect stress distribution at the bone-implant interface. This will help understand the behaviour and help predict success rates of the implant planted in different bone densities. The process of implantation involves the removal of bone from a small portion of the jawbone to replace either a lost tooth or an infected one and an implant is inserted in the cavity made as a result. Now the extent of fixation due to osseointegration is largely dependent on the condition of the bone in terms of the density. Generally, the density of the bone is classified into four categories namely D1, D2, D3, and D4; with D1 being purely cortical and D4 having higher percentage of cancellous bordered by cortical bone. A bone model with a form closely resembling the actual bone was made using 3D CAD software and was meshed using Hyper Mesh. The model was subjected to an oblique load of 120 N at 70° to the vertical to replicate occlusal loading. A finite element static analysis was done using Abaqus software. The stress distribution contours at the bone-implant contact zone were studied closely to understand the changes as a result of the varying density. It was revealed that as the quantity of the cancellous bone increased from D1 to D4 the cortical peak stress levels dropped. The bone density and the corresponding change in the material characteristics was also responsible for the variation in the peak stress and displacement values.


Asunto(s)
Densidad Ósea , Interfase Hueso-Implante , Análisis de Elementos Finitos , Estrés Mecánico , Implantes Dentales , Humanos
11.
Front Bioeng Biotechnol ; 12: 1352882, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38322788

RESUMEN

Purpose: Controversy remains regarding the optimal treatment for stage III Osteonecrosis of the femoral head (ONFH). This study presents, for the first time, the precise treatment of stage III ONFH using the "substitute the beam for a pillar" technique and performs a comparative finite element analysis with other hip-preserving procedures. Methods: A formalin-preserved femur of male cadavers was selected to obtain the CT scan data of femur. The proximal femur model was reconstructed and assembled using Mimics 20.0, Geomagic, and UG-NX 12.0 software with four different implant types: simple core decompression, fibula implantation, porous tantalum rod implantation, and partial replacement prosthesis. The finite element simulations were conducted to simulate the normal walking gait, and the stress distribution and displacement data of the femur and the implant model were obtained. Results: The peak von Mises stress of the femoral head and proximal femur in the partial replacement of the femoral head (PRFH) group were 22.8 MPa and 37.4 MPa, respectively, which were 3.1%-38.6% and 12.8%-37.4% lower than those of the other three surgical methods. Conclusion: The PRFH group exhibits better mechanical performance, reducing stress and displacement in the ONFH area, thus maintaining femoral head stability. Among the four hip-preserving approaches, from a biomechanical perspective, PRFH offers a new option for treating ONFH.

12.
J Mech Behav Biomed Mater ; 152: 106424, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38290392

RESUMEN

Magnesium/Ceria nanocomposites (Mg/xCeO2 NCs (x = 0.5 %, 1 % and 1.5 %)) prepared by using powder metallurgy and microwave sintering method are assessed for their corrosion rate for a period of 28 days. As per the immersion tests results, the addition of ceria nanoparticles to pure Mg, brought about a noteworthy improvement to corrosion resistance. A corrosion rate of approximately 0.84 mm/year for Mg/0.5CeO2 and 0.99 mm/year for Mg/1.0CeO2 nanocomposites were observed. Another aspect of the study involves employing the simulation method i.e. finite element analysis (FEA) to compare the stress distribution in magnesium-ceria nanocomposite based screws and circular bars especially for Mg/0.5CeO2 and Mg/1.0CeO2. Further, the simulation also gives a perception of the impact of masticatory forces, the biting force and shear stress exerted on the Mg/0.5CeO2 and Mg/1.0CeO2 based screws. The simulations results show that the screws showed an acceptable level of stresses for a biting force up to 300 N. The circular bar as well kept its stresses at acceptable levels for the same load of 300N. The shear stress results indicated that a biting force up to 602 N can be safely absorbed by Mg/0.5CeO2 screw. The comprehensive approach allows for a better understanding of the corrosion behavior, stress distribution, and mechanical properties of the Mg/CeO2 nanocomposites, enabling the development of effective temporary implants for craniofacial trauma fixation that can withstand normal physiological forces during mastication. The study reported in this paper aims to target Mg/xCeO2 NCs for temporary implants for craniofacial trauma fixation.


Asunto(s)
Fracturas Óseas , Reconstrucción Mandibular , Nanocompuestos , Humanos , Magnesio , Análisis de Elementos Finitos , Imagenología Tridimensional/métodos
13.
Orthop Traumatol Surg Res ; 110(1S): 103765, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37979672

RESUMEN

Posterior-stabilized total knee arthroplasty (PS-TKA) is associated with high rates of satisfaction and functional recovery. This is notably attributed to implant optimization in terms of design, choice of materials, positioning and understanding of biomechanics. Finite elements analysis (FEA) is an assessment technique that contributed to this optimization by ensuring mechanical results based on numerical simulation. By close teamwork between surgeons, researchers and engineers, FEA enabled testing of certain clinical impressions. However, the methodological features of the technique led to wide variations in the presentation and interpretation of results, requiring a certain understanding of numerical and biomechanical fields by the orthopedic community. The present study provides an up-to-date review, aiming to address the following questions: what are the principles of FEA? What is the role of FEA in studying PS design in TKA? What are the key elements in the literature for understanding the role of FEA in PS-TKA? What is the contribution of FEA for understanding of tibiofemoral and patellofemoral biomechanical behavior? What are the limitations and perspectives of digital simulation and FEA in routine practice, with a particular emphasis on the "digital twin" concept? LEVEL OF EVIDENCE: V, expert opinion.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Análisis de Elementos Finitos , Rango del Movimiento Articular , Diseño de Prótesis , Fenómenos Biomecánicos
14.
J Prosthodont ; 33(4): 348-357, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37950537

RESUMEN

PURPOSE: Single implant retained mandibular overdenture treatment has been shown to be a minimally invasive, satisfactory, and cost-effective option for edentulous individuals. However, the impact of implant diameter and length on stress distribution at the implant, bone, and other components in this treatment approach remains unclear. The purpose of this 3D finite element analysis was to evaluate the effect of implant length and diameter on equivalent von Mises stress and strain distribution in single implant retained overdentures at bone, implant, and prosthetic components. MATERIALS AND METHODS: Nine models were constructed according to implant lengths (L) (8, 10, 12 mm) and diameters (D) (3.3, 4.1, 4.8 mm). The implants were positioned axially, in the midline of the mandible. A 3D model of the edentulous mandible was created from a computed tomography image. A single implant, abutment with insert PEEK and a housing, acrylic denture, and Co-Cr framework were modeled separately. In the ANSYS software program, occlusal loads were applied as 150 N, bilaterally vertical direction, or unilaterally oblique direction to the first molar. Minimum principal stress values were evaluated for bone and equivalent von Mises stress and strain values were evaluated for implant and prosthetic components. RESULTS: Von Mises stress values for vertical load increased at implant, housing, and insert PEEK for all groups when the length of the implant increased. When oblique load was applied, 3.3 mm diameter implant groups showed maximum von Mises stress values for implants, cortical bone, cancellous bone, and housing among all groups. A minimum stress level for implant was found in D4.1/L8 group. Regarding the insert PEEK, strain values were found to be higher as the diameter of the implant increased both for vertical and oblique loads. Cortical bone showed higher minimum principal stress values as compared to cancellous bone under both loading conditions. CONCLUSIONS: The 3.3 mm diameter implant groups exhibited the highest von Mises stress and strain values for both loading conditions at the implant. The diameter of the implant had a greater impact on stress and strain levels at the implant site compared to length. For vertical loading, stress value increased at implant, housing, and PEEK when the length of the implant increased.


Asunto(s)
Benzofenonas , Implantes Dentales , Polímeros , Humanos , Prótesis de Recubrimiento , Análisis de Elementos Finitos , Prótesis Dental de Soporte Implantado , Mandíbula/cirugía , Análisis del Estrés Dental/métodos , Estrés Mecánico , Fenómenos Biomecánicos
15.
J Orthop Surg Res ; 18(1): 976, 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38115076

RESUMEN

BACKGROUND: The rolling contact joint (RCJ) mechanism is a system of constraint that allows two circular bodies connected with flexible straps to roll relative to one another without slipping. This study aims to compare the biomechanical characteristics between the conventional proximal interphalangeal joint (PIPJ) flexible hinge (FH) implant and the novel PIPJ implant adopting a RCJ mechanism during PIPJ range of motion using finite element (FE) analysis. METHODS: The three-dimensional (3D) surface shape of a conventional PIPJ FH implant was obtained using a 3D laser surface scanning system. The configuration and parameters of the novel PIPJ implant were adapted from a previous study. The two implants were assumed to have the same material characteristics and each implant was composed of a hyperelastic material, silicone elastomers. The configuration data for both implants were imported to a computer-aided design program to generate 3D geometrical surface and hyperelastic models of both implants. The hyperelastic models of both implants were imported into a structural engineering software to produce the FE mesh and to perform FE analysis. The FE analysis modeled the changes of mechanics during flexion-extension motion between 0° and 90° of two PIPJ implants. The mean and maximum values of von-Mises stress and strain as well as the total moment reaction based on the range of motion of the PIPJs were calculated. The mean values within the PIPJ's functional range of motion of the mean and maxinum von-Mises stress and strain and the total moment reaction were also determined. RESULTS: The maximum values for the von-Mises stress, and strain, as well as the total moment reactions of the conventional PIPJ FH and novel PIPJ implants were all at 90° of PIPJ flexion. The maximum value of each biomechanical property for the novel PIPJ implant was considerably lower compared with that of the conventional PIPJ FH implant. The mean values within the PIPJ's functional range of motion of the maximum von-Mises stress and strain for the novel PIPJ implant was approximately 6.43- and 6.46-fold lower compared with that of the conventional PIPJ FH implant, respectively. The mean value within a PIPJ's functional range of motion of the total moment reaction of the novel PIPJ implant was approximately 49.6-fold lower compared with that of the conventional PIPJ FH implant. CONCLUSIONS: The novel PIPJ implant with an RCJ mechanism may offer improved biomechanical performance compared with conventional PIPJ FH implant.


Asunto(s)
Articulaciones , Prótesis e Implantes , Análisis de Elementos Finitos , Estrés Mecánico , Programas Informáticos , Fenómenos Biomecánicos
16.
Front Bioeng Biotechnol ; 11: 1237702, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37790254

RESUMEN

The study aimed to investigate the impact of posterior element and ligament removal on the maximum von Mises stress, and maximum shear stress of the eight-layer annulus for treating stenosis at the L3-L4 and L4-L5 levels in the lumbar spine. Previous studies have indicated that laminectomy alone can result in segmental instability unless fusion is performed. However, no direct correlations have been established regarding the impact of posterior and ligament removal. To address this gap, four models were developed: Model 1 represented the intact L2-L5 model, while model 2 involved a unilateral laminotomy involving the removal of a section of the L4 inferior lamina and 50% of the ligament flavum between L4 and L5. Model 3 consisted of a complete laminectomy, which included the removal of the spinous process and lamina of L4, as well as the relevant connecting ligaments between L3-L4 and L4-L5 (ligament flavum, interspinous ligament, supraspinous ligament). In the fourth model, a complete laminectomy with 50% facetectomy was conducted. This involved the same removals as in model 3, along with a 50% removal of the inferior/superior facets of L4 and a 50% removal of the facet capsular ligaments between L3-L4 and L4-L5. The results indicated a significant change in the range of motion (ROM) at the L3-L4 and L4-L5 levels during flexion and torque situations, but no significant change during extension and bending simulation. The ROM increased by 10% from model 1 and 2 to model 3, and by 20% to model 4 during flexion simulation. The maximum shear stress and maximum von-Mises stress of the annulus and nucleus at the L3-L4 levels exhibited the greatest increase during flexion. In all eight layers of the annulus, there was an observed increase in both the maximum shear stress and maximum von-Mises stress from model 1&2 to model 3 and model 4, with the highest rate of increase noted in layers 7&8. These findings suggest that graded posterior element and ligament removal have a notable impact on stress distribution and range of motion in the lumbar spine, particularly during flexion.

17.
J Endod ; 49(12): 1690-1697, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37804945

RESUMEN

INTRODUCTION: This study aimed to assess the fracture resistance of mandibular first molars after preparation with 3 different access cavity designs and 2 rotary systems using finite element analysis. METHODS: Six 3-dimensionally printed mandibular first molars simulating natural teeth received traditional, conservative, and ultraconservative (truss) access cavity preparations. The root canals in each group were instrumented with either XP-Endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Switzerland) or TruNatomy (Dentsply Sirona, Ballaigues, Switzerland) rotary files. The models were individually digitized, and micro-computed tomographic scans were transferred to Mimics software (Materialise NV, Leuven, Belgium) to create a geometric model of the tooth. The designed model was exported to 3-matic software (Materialise NV), and STL files were transferred to Geomagic Design X (3D Systems, Rock Hill, SC). Point cloud data were used for surfacing and transferred to ANSYS software (Ansys, Canonsburg, PA). A 200-N superficial force was applied vertically to the buccal cusps and central fossa, and the maximum and minimum equivalent von Mises stress values were calculated and reported. RESULTS: The traditional and ultraconservative access cavity designs yielded the highest and the lowest von Mises stress values, respectively. In the ultraconservative cavity design, the stress values in pericervical dentin were lower in canal preparation with TruNatomy compared with XP-Endo Shaper. In the traditional and conservative cavity designs, stress was lower in the first 2 mm from the cementoenamel junction in the XP-Endo Shaper group and in the next 3 mm in the TruNatomy group. CONCLUSIONS: Stress was lower in the ultraconservative and conservative cavity designs compared with the traditional design. Also, root canal preparation with TruNatomy yielded lower stress values in general compared with XP-Endo Shaper.


Asunto(s)
Cavidad Pulpar , Diente Molar , Cavidad Pulpar/diagnóstico por imagen , Análisis de Elementos Finitos , Microtomografía por Rayos X , Diente Molar/diagnóstico por imagen , Preparación del Conducto Radicular/métodos
18.
Bioengineering (Basel) ; 10(9)2023 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-37760105

RESUMEN

Proximal fibular osteotomy (PFO) was found to relieve pain and improve knee function in patients with medial compartment knee osteoarthritis (OA). Therapy redistributes the load applied from the inside to the outside and alleviates the load applied on the inside through fibula osteotomy. Therefore, the clinical effect of fibular osteotomy using the finite element (FE) method was evaluated to calculate the exact change in stress inside a knee joint with varus deformity. Using CT and MRI images of a patient's lower extremities, 3D models of the bone, cartilage, meniscus, and ligaments were constructed. The varus angle, representing the inward angulation of the knee, was increased by applying a force ratio in the medial and lateral directions. The results showed that performing proximal fibular osteotomy led to a significant reduction in stress in the medial direction of the meniscus and cartilage. The stress reduction in the lateral direction was relatively minor. In conclusion, the study demonstrated that proximal fibular osteotomy effectively relieves stress and redistributes the load in the knee joints of patients with medial compartment knee osteoarthritis. The findings emphasize the importance of considering force distribution and the position of fibular osteotomy to achieve optimal clinical outcomes.

19.
Materials (Basel) ; 16(17)2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37687521

RESUMEN

As an important energy conversion component in electromagnetic-forming technology, the coil is subjected to great internal stress and is easy to break. The geometric structure and winding process of the forming coil draw on the research results of pulsed magnets. However, the two use conditions are different. It is very important to clarify the force difference between the two for the design of the forming coil. In this paper, the numerical model of an aluminum alloy (AA1060-O) is established, and the difference in force between the pulse magnet and forming coil with the same size in time and space under different working conditions is analyzed. A two-dimensional fully coupled finite element model consisting of circuit, magnetic field, and solid mechanics is established and used to determine the key parts of the coil force. It is found that the von Mises stress of the forming coil is greater than that of the pulsed magnet under the same circuit parameters and geometric structure. In the electromagnetic forming of the tube, the glass fiber is subjected to a large stress. In addition, the stress of glass fiber under the condition of tube necking is about 2 times that of pulsed magnet. When the voltage is increased, the failure of the middle part of the glass fiber causes the coil to break. In the electromagnetic forming of the sheet, the coil skeleton is subjected to large stress, and its upper end failure causes the coil to break. Therefore, new design ideas for forming coils under different working conditions are proposed.

20.
Microvasc Res ; 150: 104594, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37579814

RESUMEN

Retinal hemodynamics and biomechanics play a significant role in understanding the pathophysiology of several ocular diseases. However, these parameters are significantly affected due to changed blood vessel morphology ascribed to pathological conditions, particularly diabetes. In this study, an image-based computational fluid dynamics (CFD) model is applied to examine the effects of changed vascular morphology due to diabetes on blood flow velocity, vorticity, wall shear stress (WSS), and oxygen distribution and compare it with healthy. The 3D patient-specific vascular architecture of diabetic and healthy retina is extracted from Optical Coherence Tomography Angiography (OCTA) images and fundus to extract the capillary level information. Further, Fluid-structure interaction (FSI) simulations have been performed to compare the induced tissue stresses in diabetic and healthy conditions. Results illustrate that most arterioles possess higher velocity, vorticity, WSS, and lesser oxygen concentration than arteries for healthy and diabetic cases. However, an opposite trend is observed for venules and veins. Comparisons show that, on average, the blood flow velocity in the healthy case decreases by 42 % in arteries and 21 % in veins, respectively, compared to diabetic. In addition, the WSS and von Mises stress (VMS) in healthy case decrease by 49 % and 72 % in arteries and by 6 % and 28 % in veins, respectively, when compared with diabetic, making diabetic blood vessels more susceptible to wall rupture and tissue damage. The in-silico results may help predict the possible abnormalities region early, helping the ophthalmologists use these estimates as prognostic tools and tailor patient-specific treatment plans.


Asunto(s)
Diabetes Mellitus , Modelos Cardiovasculares , Humanos , Fenómenos Biomecánicos , Hemodinámica , Retina , Velocidad del Flujo Sanguíneo , Estrés Mecánico , Hidrodinámica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA