Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Childs Nerv Syst ; 40(9): 2851-2858, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38714605

RESUMEN

INTRODUCTION: Most myelomeningocele (MMC) cases present with ventriculomegaly or hydrocephalus, yet a comprehensive volumetric assessment of MMC intracranial structures is lacking. This study aimed to provide baseline data on intracranial structural volumes immediately after birth in MMC infants who underwent repair surgeries after birth (postnatal repair). METHODS: In this retrospective single-center study, we analyzed 52 MMC infants undergoing postnatal repair, utilizing head computed tomography scans at birth for volumetric assessment. Intracranial volume (ICV), lateral ventricles volume (LVV), choroid plexus volume (CPV), and posterior cranial fossa volume (PCFV) were measured. Hydrocephalus was classified into no hydrocephalus, progressive hydrocephalus, and hydrocephalus at birth. Comparative analysis employed the Wilcoxon rank-sum test. Receiver operating characteristic (ROC) analysis discriminated cases with and without ventriculoperitoneal shunt (VPS). RESULTS: The median values were 407.50 mL for ICV, 33.18 mL for LVV, 0.67 mL for CPV, and 21.35 mL for PCFV. Thirty-seven cases (71.15%) underwent VPS. ROC analysis revealed an LVV cut-off value of 6.74 mL for discriminating cases with and without VPS. Progressive hydrocephalus showed no significant difference in ICV but significantly larger LVV compared to no hydrocephalus. Hydrocephalus at birth demonstrated statistically larger ICV and LVV compared to the other two types. CONCLUSION: Baseline volumetric data were provided, and volumetric analysis exhibited statistical differences among three hydrocephalus types. These findings enhance our understanding of intracranial volumetric changes in MMC, facilitating more objective assessments of MMC cases.


Asunto(s)
Hidrocefalia , Meningomielocele , Humanos , Meningomielocele/cirugía , Meningomielocele/diagnóstico por imagen , Femenino , Masculino , Estudios Retrospectivos , Hidrocefalia/cirugía , Hidrocefalia/diagnóstico por imagen , Hidrocefalia/etiología , Recién Nacido , Lactante , Derivación Ventriculoperitoneal/métodos , Tomografía Computarizada por Rayos X/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Plexo Coroideo/diagnóstico por imagen , Plexo Coroideo/cirugía
2.
Jpn J Radiol ; 42(8): 832-840, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38581478

RESUMEN

PURPOSE: The diagnosis of progressive fibrosing interstitial lung disease (PF-ILD) using computed tomography (CT) is an important medical practice in respiratory care, and most imaging findings for this disease have been obtained with inspiratory CT. It is possible that some characteristic changes in respiration may be seen in normal and diseased lung in PF-ILD, which may lead to a new understanding of the pathogenesis of interstitial pneumonia, but it has never been examined. In this study, we collected and selected inspiratory and expiratory CT scans performed in pure PF-ILD cases, and evaluated the volumes of diseased and normal lung separately by manual detection and 3-dimensional volumetry to characterize the dynamic features of PF-ILD. MATERIALS AND METHODS: Cases were collected retrospectively from a total of 753 inspiratory and expiratory CT scans performed at our hospital over a 3-year period. Sixteen cases of pure PF-ILD, excluding almost all other diseases, were included. We measured their diseased, normal, and the whole lung volumes manually and evaluated the correlation of their values and their relationship with respiratory function tests (FVC, FVC%-predicted, and DLCO%-predicted). RESULTS: The relative expansion rate of the diseased lung is no less than that of the normal lung. The "Expansion volume of total lung" divided by the "Expansion volume of normal lung" was found to be significantly associated with DLCO%-predicted abnormalities (p = 0.0073). CONCLUSION: The diseased lung in PF-ILD retained expansion capacity comparable to the normal lung, suggesting a negative impact on respiratory function.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Tomografía Computarizada por Rayos X , Humanos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/fisiopatología , Femenino , Tomografía Computarizada por Rayos X/métodos , Masculino , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Progresión de la Enfermedad , Pruebas de Función Respiratoria , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Inhalación/fisiología , Anciano de 80 o más Años , Espiración/fisiología
3.
Acta Radiol ; 65(5): 506-512, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38591942

RESUMEN

BACKGROUND: Apparent diffusion coefficient (ADC) value is an important part of bladder cancer magnetic resonance imaging (MRI) assessment and can predict the aggressive and invasive potentials. There is growing interest in whole tumor volume measurements. PURPOSE: To investigate if the volumetric ADC measurement method will significantly exceed the diagnostic performance of the selected region of interest (ROI) method in everyday practice. MATERIAL AND METHODS: A prospective evaluation was carried out of 50 patients with bladder cancer by two radiologists. The mean and the minimum ADC values were measured using both methods. The inter-reader agreement was determined by the intraclass correlation coefficient. The ADC values were compared between different grades, states of muscle invasion, and lympho-vascular invasion (LVI); then, validity was evaluated using receiver operating characteristic (ROC) curves. Areas under the curve (AUC) were then compared for the level of statistical significance. RESULTS: The inter-observer agreement was excellent for the ADC values using both methods. The volumetric measurement provides higher mean and lower minimum ADC values with statistically significant differences (P <0.00001). The highest diagnostic accuracy for differentiating tumor grade and predicting muscle invasion was for the minimum ADC by a selected ROI. However, the differences between the achieved AUCs were of no statistical significance. None of the ADC values predicted LVI with statistical significance. CONCLUSION: The selected ROI and volumetric measurement methods of mean and minimum ADC in bladder cancer yield different values, still having comparable diagnostic performance with accurate ROI sampling. The minimum ADC value by ROI is preferred in everyday clinical practice.


Asunto(s)
Neoplasias de la Vejiga Urinaria , Humanos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Femenino , Masculino , Anciano , Persona de Mediana Edad , Estudios Prospectivos , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Adulto , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Carga Tumoral , Variaciones Dependientes del Observador , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/patología , Invasividad Neoplásica/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos
4.
Diagn Interv Radiol ; 30(4): 220-227, 2024 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-38375767

RESUMEN

PURPOSE: In this case-control study, we aimed to evaluate how muscle volume affects pelvic floor function by analyzing the levator ani muscle (LAM) using volumetric segmentation in addition to standard magnetic resonance (MR) defecography assessments. METHODS: We enrolled 85 patients with varying degrees of pelvic floor dysfunction (PFD) and 85 age- and gender-matched controls in this retrospective study. All patients had MR defecography images, while all controls had pelvic MR images obtained for other reasons. Group comparisons were performed using independent samples t-tests and Mann-Whitney U tests. The receiver operating curve (ROC) was constructed to establish a cut-off value for a normal LAM volume. Interrater reliability was assessed by calculating the intraclass correlation coefficient. A P value of less than 0.05 was considered statistically significant. RESULTS: Volumetric measurements revealed that the control group had higher LAM volumes, and the ROC curve analysis indicated a cut-off value of 38934.3 mm3 with a sensitivity of 0.812 and specificity of 0.8 for PFD assessment using LAM volumetric measurement. Gender did not significantly affect LAM volume in the control group. CONCLUSION: Alongside the useful structural and functional information acquired from MR defecography images, volumetric analysis, and three-dimensional reconstructions of LAM may help to improve the accuracy of the diagnosis.


Asunto(s)
Imagen por Resonancia Magnética , Diafragma Pélvico , Humanos , Femenino , Imagen por Resonancia Magnética/métodos , Diafragma Pélvico/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Estudios de Casos y Controles , Adulto , Anciano , Defecografía/métodos , Reproducibilidad de los Resultados , Trastornos del Suelo Pélvico/diagnóstico por imagen , Imagenología Tridimensional/métodos , Curva ROC , Sensibilidad y Especificidad
5.
J Vet Med Sci ; 86(1): 28-34, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38008443

RESUMEN

The vertebral heart scale (VHS) is the most common method used for the objective evaluation of heart size, however, VHS cannot evaluate the entire heart area. This retrospective study aimed to evaluate the development and feasibility of vertebral heart area ratio (VHAR=heart area/the fourth thoracic vertebra [T4] body area) as a new cardiac measurement method. A total of 125 dogs considered without clinical heart abnormalities in the pre-anesthetic examination, measurements of the VHS and VHAR using thoracic radiography were compared with computed tomography measurements of the vertebral cardiac volume ratio (VCVR=cardiac volume/T4 body volume) and investigate whether the VHAR values differed between observers. The mean cardiac and T4 body volumes were 116.99 ± 108.07 cm3 and 0.92 ± 0.91 cm3, respectively. The mean values of observers 1 and 2 were 9.9 ± 0.7 v (VHS), 42.64 ± 27.94 cm2 (heart area), and 1.37 ± 0.96 cm2 (T4 body area). Intraclass coefficients were the highest for the heart area, followed by the T4 body area and VHS. The VHAR showed a moderate correlation with VHS in observers 1 (r=0.671) and 2 (r=0.633). The VCVR showed a more positive correlation with VHAR (r=0.573) than with VHS (r=0.426). These results indicated that VHAR could be used as a complement to VHS for heart size measurement, and the high degree of observer agreement for the measurements indicated the measurement reproducibility of VHAR.


Asunto(s)
Corazón , Vértebras Torácicas , Perros , Animales , Estudios Retrospectivos , Reproducibilidad de los Resultados , Estudios de Factibilidad , Corazón/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen
6.
Dermatol Ther (Heidelb) ; 14(1): 233-249, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38100073

RESUMEN

BACKGROUND: The excellent efficacy is mitigated by the limited safety profile of microfocused ultrasound procedures. OBJECTIVE: We sought to assess the safety and tightening efficacy of a novel microfocused ultrasound. METHODS: The randomized middle and lower face and submental region of the participants were treated with the novel device using the following transducers: M4.5, D4.5, M3.0, and D3.0. Improvement in paired comparison of pretreatment and posttreatment photographs, three-dimensional (3D) volumetric assessments, skin thickness measured by B-ultrasonography, and skin photoaging parameters were evaluated. Adverse events and patient satisfaction were also recorded. RESULTS: A total of 20 participants (20 female) were enrolled. Fourteen of 20 participants (70%) were judged to show clinically significant facial tightening during 3-month follow-up (P < 0.05). The mean volumetric change in the lower face, as quantitatively assessed after 3 months was -0.29 mL compared with +0.42 mL on the control side (P < 0.05). The VAS pain score was 3.00 ± 1.19 without any oral or intramuscular anesthesia. CONCLUSIONS: A small sample size, lack of clinical scales, and impersonalized treatment parameters. The novel microfocused ultrasound appears to be a safe and effective modality for lower-face tightening. CLINICAL TRIAL REGISTRATION NUMBER: ChiCTR 2200064666.

7.
Acta Otolaryngol ; 143(8): 631-635, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37537926

RESUMEN

BACKGROUND: Orthostatic dizziness/vertigo (ODV) is characterized by lightheadedness owing to postural changes. AIMS/OBJECTIVES: To measure the endolymphatic space (ELS)/total fluid space (TFS) volume ratio and the distribution rate of endolymphatic fluid (ELF) of patients with ODV and compare them with those of control subjects (CS). MATERIALS AND METHODS: This study included 22 patients (44 ears) with ODV and 52 controls (104 ears, CS). The ELS/TFS volume ratio (%) and distribution rate (%) of the inner ear components were measured using 3-dimensional magnetic resonance imaging. RESULTS: In the ODV group, the mean ELS/TFS volume ratios of the cochlea, vestibule, and semi-circular canals (SCCs) were 12.1%, 18.6%, and 18.1%, respectively; the mean ELS distribution rates for the cochlea, vestibule, and SCCs were 27.3%, 26.2%, and 46.6%, respectively. The ELS distribution rate of the vestibule was significantly lower (p < .01) and the ELS distribution rate of the SCCs was significantly higher in the ODV than in the CS group (p < .01). CONCLUSIONS AND SIGNIFICANCE: The ELS distribution rate in the vestibule + SCCs among patients with ODV did not differ from that in the CS; ELF in the vestibule moved to the SCCs, and a large amount of ELF was distributed only in the SCCs.


Asunto(s)
Hidropesía Endolinfática , Enfermedad de Meniere , Vestíbulo del Laberinto , Humanos , Mareo , Hidropesía Endolinfática/patología , Enfermedad de Meniere/complicaciones , Enfermedad de Meniere/diagnóstico por imagen , Enfermedad de Meniere/patología , Vértigo/diagnóstico por imagen , Vestíbulo del Laberinto/patología , Imagen por Resonancia Magnética/métodos
8.
J Clin Med ; 12(12)2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37373862

RESUMEN

Pelvic ring injuries are uncommon but serious injuries. Percutaneous sacro-iliac screw fixation (SSF) is the standard treatment for posterior stabilization of pelvic fractures. Compression forces of the SSF might cause deformity of the sacrum and the pelvic ring. The aim of this radio-volumetric study is to evaluate the morphometry of the sacrum and pelvic ring in SSF for posterior pelvic fractures. (1) Methods: We conducted a radio-volumetric study measuring the bony sacral volume before and after SSF for a pelvic fracture based on a three-dimensional reconstruction of the pre- and postoperative computed tomography scan of 19 patients with a C-type pelvic fracture. In addition to the bony sacral volume, we assessed the pelvic deformity and the load bearing axis. We compared the results of patients without anterior stabilization (Group A) to patients who had additional ORIF of the anterior pelvic ring. (2) Results: Median age of the patients was 41.2 years (±17.8). All patients received percutaneous SSF with partially threaded 7.3 mm screws. The sacral volume decreased from 202.9 to 194.3 cm3 in group A (non-operative treatment anterior, n = 10) and an increase of sacral volume from 229.8 to 250.4 cm3 in group B (anterior ORIF; n = 9). Evaluation of the pelvic deformity also reflected this trend by a decrease of the ipsilateral load-bearing angle in group A (37.0° to 36.4°) and an increase of this angle in group B (36.3 to 39.9°). (3) Conclusions: Bony sacral volume and pelvic deformity after sacro-iliac screw fixation in pelvic fractures depend on treatment of the anterior pelvic ring. Reduction and fixation of the anterior fracture shows an increase of the bony sacral volume and the load bearing angle leading to a closer to normal reconstruction of the pelvic anatomy.

9.
J Neurooncol ; 162(2): 363-371, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36988746

RESUMEN

PURPOSE: The Response Assessment in Neuro-Oncology Brain Metastases (RANO-BM) working group proposed a guide for treatment responses for BMs by utilizing the longest diameter; however, despite recognizing that many patients with BMs have sub-centimeter lesions, the group referred to these lesions as unmeasurable due to issues with repeatability and interpretation. In light of RANO-BM recommendations, we aimed to correlate linear and volumetric measurements in sub-centimeter BMs on contrast-enhanced MRI using intelligent automation software. METHODS: In this retrospective study, patients with BMs scanned with MRI between January 1, 2018, and December 31, 2021, were screened. Inclusion criteria were: (1) at least one sub-centimeter BM with an integer millimeter-longest diameter was noted in the MRI report; (2) patients were a minimum of 18 years of age; (3) patients with available pre-treatment three-dimensional T1-weighted spoiled gradient-echo MRI scan. The screening was terminated when there were 20 lesions in each group. Lesion volumes were measured with the help of intelligent automation software Jazz (AI Medical, Zollikon, Switzerland) by two readers. The Kruskal-Wallis test was used to compare volumetric differences. RESULTS: Our study included 180 patients. The agreement for volumetric measurements was excellent between the two readers. The volumes of the following groups were not significantly different: 1-2 mm, 1-3 mm, 1-4 mm, 2-3 mm, 2-4 mm, 3-4 mm, 3-5 mm, 4-5 mm, 5-6 mm, 5-7 mm, 6-7 mm, 6-8 mm, 6-9 mm, 7-8 mm, 7-9 mm, 8-9 mm. CONCLUSION: Our findings indicate that the largest diameter of a lesion may not accurately represent its volume. Additional research is required to determine which method is superior for measuring radiologic response to therapy and which parameter correlates best with clinical improvement or deterioration.


Asunto(s)
Neoplasias Encefálicas , Imagen por Resonancia Magnética , Humanos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Neoplasias Encefálicas/patología , Programas Informáticos , Automatización
10.
BMC Oral Health ; 23(1): 102, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36793033

RESUMEN

OBJECTIVES: To investigate the potential influence of different grafting materials on maxillary sinus membrane dimensions and ostium patency following lateral sinus floor elevation (SFE) as assessed using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: A total of 40 sinuses in 40 patients were included. Twenty sinuses were referred for SFE with deproteinized bovine bone mineral (DBBM), and the remaining 20 sinuses were grafted with calcium phosphate (CP). CBCT was performed prior to and 3 to 4 days after surgery. The dimensions of the Schneiderian membrane volume and ostium patency were evaluated, and potential relationships between volumetric changes and any associated factors were analyzed. RESULTS: The median increase in membrane-whole cavity volume ratios was 43.97% in the DBBM group and 67.58% in the CP group, demonstrating no statistically significant difference (p = 0.17). The rates of increased obstruction after SFE were 11.1% for the DBBM group versus 44.4% for the CP group (p = 0.03). The graft volume was found to be positively correlated with the postoperative membrane-whole cavity volume ratio (r = 0.79; p < 0.01) and the membrane-whole cavity volume ratio increase (r = 0.71; p < 0.01). CONCLUSIONS: The two grafting materials seem to have a similar effect on transient volumetric changes in the sinus mucosa. However, the choice of grafting material should still be made with caution since sinuses grafted using DBBM exhibited less swelling and less ostium obstruction.


Asunto(s)
Elevación del Piso del Seno Maxilar , Senos Transversos , Humanos , Animales , Bovinos , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/cirugía , Elevación del Piso del Seno Maxilar/métodos , Tomografía Computarizada de Haz Cónico , Maxilar/cirugía , Mucosa Nasal/diagnóstico por imagen
11.
Insights Imaging ; 13(1): 180, 2022 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-36417131

RESUMEN

Intracerebral hemorrhage (ICH) accounts for 10-20% of all strokes worldwide and is associated with serious outcomes, including a 30-day mortality rate of up to 40%. Neuroimaging is pivotal in diagnosing ICH as early detection and determination of underlying cause, and risk for expansion/rebleeding is essential in providing the correct treatment. Non-contrast computed tomography (NCCT) is the most used modality for detection of ICH, identification of prognostic markers and measurements of hematoma volume, all of which are of major importance to predict outcome. The strongest predictors of 30-day mortality and functional outcome for ICH patients are baseline hematoma volume and hematoma expansion. Even so, exact hematoma measurement is rare in clinical routine practice, primarily due to a lack of tools available for fast, effective, and reliable volumetric tools. In this educational review, we discuss neuroimaging findings for ICH from NCCT images, and their prognostic value, as well as the use of semi-automatic and fully automated hematoma volumetric methods and assessment of hematoma expansion in prognostic studies.

12.
Ophthalmol Sci ; 2(1): 100096, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36246173

RESUMEN

Purpose: To develop a method to determine the volume of peripapillary hyperreflective ovoid masslike structures (PHOMS) and to examine the correlation between PHOMS and anatomic optic nerve head characteristics in a large cohort of patients with optic disc drusen (ODD). Design: Retrospective, observational study of patients with ODD. Participants: Patients with ODD seen in a 3-year period. Methods: We determined the prevalence of PHOMS. We then developed a method to calculate the volume of PHOMS and measured this in all patients where radial scans on OCT were available. We analyzed the correlation between PHOMS volume and patient age, size of Bruch's membrane opening (BMO), ODD visibility, and anatomic location of ODD in the optic nerve. Main Outcome Measures: Prevalence and characteristics of PHOMS in patients with ODD. Results: In 247 (77%) eyes with ODD, PHOMS were found. Among these, 80% were in the first decade of life, 87% were in the second decade, 89% were in the third decade, 85% were in the fourth decade, 74% were in the fifth decade, 73% were in the sixth decade, 58% were in the seventh decade, 40% were in the eighth decade, and 0% were in the ninth decade. The ophthalmoscopic visibility of ODD increased with age. The volume of PHOMS decreased with age, but with no correlation to the size of BMO. The median volume of PHOMS was 0.27 mm3 (interquartile range [IQR], 0.13-0.49 mm3). Predominantly, PHOMS were observed in the nasal peripapillary area (87.5% nasal, 78.5% superior, 67% inferior, and 63.5% temporal). Conclusions: In patients with ODD, PHOMS are seen frequently, with the highest prevalence in younger individuals. The volume of PHOMS decreases with age, and PHOMS are seen more frequently in patients with superficial ODD.

13.
Front Oncol ; 12: 984626, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36033453

RESUMEN

Purpose: In clinical work, accurately measuring the volume and the size of breast cancer is significant to develop a treatment plan. However, it is time-consuming, and inter- and intra-observer variations among radiologists exist. The purpose of this study was to assess the performance of a Res-UNet convolutional neural network based on automatic segmentation for size and volumetric measurement of mass enhancement breast cancer on magnetic resonance imaging (MRI). Materials and methods: A total of 1,000 female breast cancer patients who underwent preoperative 1.5-T dynamic contrast-enhanced MRI prior to treatment were selected from January 2015 to October 2021 and randomly divided into a training cohort (n = 800) and a testing cohort (n = 200). Compared with the masks named ground truth delineated manually by radiologists, the model performance on segmentation was evaluated with dice similarity coefficient (DSC) and intraclass correlation coefficient (ICC). The performance of tumor (T) stage classification was evaluated with accuracy, sensitivity, and specificity. Results: In the test cohort, the DSC of automatic segmentation reached 0.89. Excellent concordance (ICC > 0.95) of the maximal and minimal diameter and good concordance (ICC > 0.80) of volumetric measurement were shown between the model and the radiologists. The trained model took approximately 10-15 s to provide automatic segmentation and classified the T stage with an overall accuracy of 0.93, sensitivity of 0.94, 0.94, and 0.75, and specificity of 0.95, 0.92, and 0.99, respectively, in T1, T2, and T3. Conclusions: Our model demonstrated good performance and reliability for automatic segmentation for size and volumetric measurement of breast cancer, which can be time-saving and effective in clinical decision-making.

14.
J Hazard Mater ; 432: 128755, 2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35358765

RESUMEN

A novel method for the volumetric detection of microplastics in various environmental (soil, water) and food (fish, meat) matrices was developed. The method is based on the Nile Red staining of microplastics while eliminating probable interference by other organic polymers such as lignin, chitin, cellulosic materials, and other organic substances using a mixture of three water-based dyes (Calcofluor White, Evans Blue, and 4,6-diamidino-2-phenylindole [DAPI]). The excitation/emission 'sweet spot' was determined for water based blue dyes to detect them in a single channel for effective elimination of probable contaminations. Detection of microplastic particles using the Nile Red method was validated by comparing with traditional detection of microplastics via Fourier transform infrared spectroscopy (FTIR). Volumetric measurements of the microplastics present in environmental samples were made possible using Z-stack confocal microscopy images backed by threshold-based 3D segmentation. Regularly shaped microplastic materials were used to validate the volumetric measurement method. The proposed volumetric determination method will be very useful for screening microplastics in diverse media and improving the prevailing method using FTIR.


Asunto(s)
Microplásticos , Contaminantes Químicos del Agua , Animales , Colorantes , Monitoreo del Ambiente , Plásticos , Coloración y Etiquetado , Agua , Contaminantes Químicos del Agua/análisis
15.
Acta Otolaryngol ; 142(2): 113-117, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35148250

RESUMEN

BACKGROUND: Benign paroxysmal positional vertigo (BPPV) is the most common peripheral vestibular disease. It is characterised by sudden onset short lived vertigo triggered by sudden changes in head position relative to gravity. AIMS/OBJECTIVES: We aimed to perform a quantitative volumetric analysis of the inner ear endolymphatic space in patients with BPPV. MATERIAL AND METHODS: This study included 67 patients with BPPV and 50 control subjects (CS). The endolymphatic space/total fluid space volume ratio (%) and the distribution rate of the inner ear components in the endolymphatic space (%) were measured using three-dimensional magnetic resonance imaging. RESULTS: Differences in the endolymphatic space/total fluid space volume ratio of the inner ear, cochlea, vestibule, and semi-circular canals (SCCs) between the CS and BPPV groups were not significant. The endolymphatic space distribution rate of the vestibule in the BPPV group was significantly lower than that in the CS group, and the endolymphatic space distribution rate of SCCs in the BPPV group was significantly higher than that in the CS group. CONCLUSIONS AND SIGNIFICANCE: Extended endolymphatic space in patients with BPPV did not exist. The otoconia released from the damaged utricles were considered to move with the endolymphatic flow toward SCCs.


Asunto(s)
Enfermedades Vestibulares , Vestíbulo del Laberinto , Vértigo Posicional Paroxístico Benigno/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Sáculo y Utrículo , Canales Semicirculares
16.
J Magn Reson Imaging ; 55(5): 1559-1568, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34582062

RESUMEN

BACKGROUND: Reliable measurements of cervical cord atrophy progression may be useful for monitoring neurodegeneration in multiple sclerosis (MS). PURPOSE: To compare a new, registration-based (Reg) method with two existing methods (active surface [AS] and propagation segmentation [PropSeg]) to measure cord atrophy changes over time in MS. STUDY TYPE: Retrospective. SUBJECTS: Cohort I: Eight healthy controls (HC) and 28 MS patients enrolled at a single institution, and cohort II: 25 HC and 63 MS patients enrolled at three European sites. FIELD STRENGTH/SEQUENCE: 3D T1-weighted gradient echo sequence, acquired at 1.5 T (cohort I) and 3.0 T (cohort II). ASSESSMENT: Percentage cord area changes (PCACs) between baseline and follow-up (cohort I: 2.34 years [interquartile range = 2.00-2.55 years], cohort II: 1.05 years [interquartile range = 1.01-1.18 years]) were evaluated for all subjects using Reg, AS, and PropSeg. Reg included an accurate registration of baseline and follow-up straightened cord images, followed by AS-based optimized cord segmentation. A subset of studies was analyzed twice by two observers. STATISTICAL TESTS: Linear regression models were used to estimate annualized PCAC, and effect sizes expressed as the ratio between the estimated differences and HC error term (P < 0.05). Reproducibility was assessed by linear mixed-effect models. Annualized PCACs were used for sample size calculations (significance: α = 0.05, power: 1 - ß = 0.80). RESULTS: Annualized PCACs and related standard errors (SEs) were lower with Reg than with other methods: PCAC in MS patients at 1.5 T was -1.12% (SE = 0.22) with Reg, -1.32% (SE = 0.30) with AS, and -1.40% (SE = 0.33) with PropSeg, while at 3.0 T PCAC was -0.83% (SE = 0.25) with Reg, -0.92% (SE = 0.32) with AS, and -1.18 (SE = 0.53) with PropSeg. This was reflected in larger effect sizes and lower sample sizes. Intra- and inter-observer agreement range was 0.72-0.91 with AS, and it was >0.96 with Reg. DATA CONCLUSION: The results support the use of the registration method to measure cervical cord atrophy progression in future MS clinical studies. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Esclerosis Múltiple , Atrofia/patología , Humanos , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Médula Espinal/diagnóstico por imagen , Médula Espinal/patología
17.
Acta Radiol ; 63(8): 1023-1031, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34259021

RESUMEN

BACKGROUND: Breast density is an independent predictor of breast cancer risk. Quantitative volumetric breast density (QVBD) is expected to provide more information on the prediction of breast cancer risk. PURPOSE: To evaluate the reliability of QVBD measurements based on cone-beam breast computed tomography (CBBCT) images. MATERIAL AND METHODS: A total of 216 breasts were used to evaluate the stability of QVBD measurements based on CBBCT images and the correlations between this volumetric measurement and visual and area-based measurement methods. The intra- and inter-observer consistency of QVBD measurements were compared. Visual breast density (VBD) was evaluated with Breast Imaging Reporting and Data System (BI-RADS) standard on CBBCT images. The correlation between QVBD and VBD was evaluated by Spearman correlation coefficient. Receiver operating characteristic (ROC) curve was used to assess the sensitivity and specificity of the volumetric method in distinguishing dense and non-dense breasts. The correlation between QVBD and quantitative area-based breast density (QABD) was determined with Pearson correlation coefficient. Then, the breast volume measured with CBBCT images was compared with the breast specimen obtained during nipple-sparing mastectomy (NSM) by Pearson correlation coefficient and linear regression. RESULTS: Excellent intra- and inter-observer consistency was found from QVBD measurements. The volumetric method distinguished dense and non-dense breasts at a cutoff value of 9.5%, with 94.5% sensitivity and 77.1% specificity. Positive correlations were found between QVBD and QABD (r=0.890; P<0.001) and between the volume measured with CBBCT images and Archimedes method (r=0.969; P<0.001). CONCLUSION: CBBCT images can evaluate breast density reliably on a continuous scale.


Asunto(s)
Densidad de la Mama , Neoplasias de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Femenino , Humanos , Imagenología Tridimensional , Mamografía/métodos , Mastectomía , Reproducibilidad de los Resultados
18.
Front Med (Lausanne) ; 8: 764236, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34901081

RESUMEN

Purpose: To evaluate the precision of individual and combined macula and optic disc volumetric analysis, and the agreement between these two scan modes with spectral domain optical coherence tomography (OCT). Methods: Macular and optic disc volumetric measurements were performed with individual and combined scan protocols in one eye of 75 healthy subjects. Three repeated measurements were performed with each protocol. From the macular area, retinal thickness in nine different sectors and ganglion cell complex thickness in eight different sectors were analyzed from both scan modes. From the optic disc area, the peripapillary retinal nerve fiber layer (pRNFL) thickness in 12 clock sectors and the optic disc parameters were evaluated. For all the parameters, repeatability limit and agreement analysis were performed. Results: For the retinal thickness measurements in macula, the combined scan had two to three times larger repeatability limit than the individual scan for all the sectors except the central sector, where the repeatability limit was five times larger. The limits of agreement intervals were lower than 20 µm for all sectors, except the central. The ganglion cell complex measurements also had larger repeatability limits for the combined scans, and the limits of agreement intervals were <10 µm for all sectors. For the pRNFL thickness, the repeatability values were distributed like a vertically elongated ellipse for both scans, but still the repeatability was better for individual scan compared to the combined scan. The shortest and widest interval are obtained for sectors 9 (9 µm) and 12 (40 µm), respectively. The repeatability limit was <0.15 units for all disc parameters with both scan modes. Conclusion: The individual macula and optic disc scans had better repeatability than the combined scan mode, and the two scan modes cannot be used interchangeability due to the wide limits of agreement.

19.
Pol J Radiol ; 86: e594-e600, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34876940

RESUMEN

PURPOSE: Target lesion selection is known to be a major factor for inter-reader discordance in RECIST 1.1. The purpose of this study was to assess whether volumetric measurements of target lesions result in different response categorization, as opposed to standard unidimensional measurements, and to evaluate the impact on inter-reader agreement for response categorization when different readers select different sets of target lesions. MATERIAL AND METHODS: Fifty patients with measurable disease from solid tumours, in which 3 readers had blindly and independently selected different sets of target lesions and subsequently reached clinically significant discordant response categorizations (progressive disease [PD] vs. non-progressive disease [non-PD]) based on RECIST 1.1 analyses were included in this study. Additional volumetric measurements of all target lesions were performed by the same readers in a second read. Intra-reader agreement between standard unidimensional measurements (uRECIST) and volumetric measurements (vRECIST) was assessed using Cohen's k statistics. Fleiss k statistics was used to analyse the inter-reader agreement for uRECIST and vRECIST results. RESULTS: The 3 readers assigned the same response classifications based on uRECIST and vRECIST in 33/50 (66%), 42/50 patients (84%), and 44/50 patients (88%), respectively. Inter-reader agreement improved from 0% when using uRECIST to 36% when using vRECIST. CONCLUSIONS: Volumetric measurement of target lesions may improve inter-reader variability for response assessment as opposed to standard unidimensional measurements. However, in about two-thirds of patients, readers disagreed regardless of the measurement method, indicating that a limited set of target lesions may not be sufficiently representative of the whole-body tumour burden.

20.
Acta Otolaryngol ; 141(12): 1033-1037, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34807797

RESUMEN

BACKGROUND: Endolymphatic hydrops (ELH), which is a pathological feature of Meniere's disease (MD), is characterized by an extended endolymphatic space (ELS). AIMS/OBJECTIVES: We aimed to perform a quantitative volumetric analysis of inner-ear ELH in patients with unilateral MD (uMD). MATERIAL AND METHODS: This study included 97 patients with definite uMD and 49 control subjects (CS). The ELS/total fluid space (TFS) volume ratio (%) and the distribution rate of the inner-ear components in the ELS (%) were measured using 3D magnetic resonance imaging and compared between patients with uMD and CS. RESULTS: Compared to CS, patients with uMD had significantly higher mean ELS/TFS volume ratios for inner-ear components. The mean distribution rate of the inner-ear components in the ELS was not significantly different between the two groups. CONCLUSIONS AND SIGNIFICANCE: In patients with uMD, ELH was noted to be spread throughout the entire inner ear and the endolymph was evenly distributed in the total ELS. These findings should be useful as a standard reference for further research.


Asunto(s)
Oído Interno/diagnóstico por imagen , Hidropesía Endolinfática/diagnóstico por imagen , Imagen por Resonancia Magnética , Enfermedad de Meniere/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Oído Interno/anatomía & histología , Oído Interno/patología , Hidropesía Endolinfática/complicaciones , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Enfermedad de Meniere/complicaciones , Enfermedad de Meniere/patología , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA