Clinics (Sao Paulo) ; 79: 100467, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39216122

RESUMEN

OBJECTIVE: Aortic Dissection (AD) is one of the most fatal acute diseases in cardiovascular diseases, with rapid onset and progression and a high fatality rate. This study aims to investigate the clinical values of non-enhancement peripheral pulse-gating rapid magnetic resonance imaging in deterministic diagnosis of AD. METHODS: Aorta magnetic resonance imaging was performed in 21 healthy volunteers at a 1.5t MR scanner sequences including cardiac-gated and peripheral pulse-gated True-FISP and HASTE were carried out separately. Acquisition Time (TA), Signal to Noise Ratio (SNR), Contrast Noise Ratio (CNR), and entirety of vessel wall blood flow artifacts were measured and compared. A total of 56 AD cases were displayed by non-enhancement peripheral pulse-gating fast MR imaging, and the results were compared with pathological findings or CTA of the aorta. The dissection rupture, tear film, true and false lumen, thrombosis, hydropericardium, and the main branches of AD were evaluated respectively. RESULTS: There were no significant differences in SNR, CNR, entirety of the vessel wall, and blood flow artifact between cardiac-gated and peripheral pulse-gated fast MR imaging. Non-enhancement pulse-gated fast scanning takes less TA time. By the pulse-gated non-enhancement fast MR imaging, the dissection rupture, tear film, true and false cavity, thrombosis, hydropericardium, and the main branches of aortic dissection were shown clearly. Multi-planar and multi-angle scans helped to show the extent of entrapment rupture, whereas partial complex tears or bi-directional tears were slightly less well visualized. CONCLUSION: Non-enhancement peripheral pulse-gated rapid magnetic resonance imaging can be used for deterministic diagnosis of AD.


Asunto(s)
Disección Aórtica , Imagen por Resonancia Magnética , Humanos , Disección Aórtica/diagnóstico por imagen , Masculino , Femenino , Adulto , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Relación Señal-Ruido , Aneurisma de la Aorta/diagnóstico por imagen , Anciano , Reproducibilidad de los Resultados , Adulto Joven , Técnicas de Imagen Sincronizada Cardíacas/métodos , Valores de Referencia
2.
Clinics ; Clinics;79: 100467, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1574776

RESUMEN

Abstract Objective: Aortic Dissection (AD) is one of the most fatal acute diseases in cardiovascular diseases, with rapid onset and progression and a high fatality rate. This study aims to investigate the clinical values of non-enhancement peripheral pulse-gating rapid magnetic resonance imaging in deterministic diagnosis of AD. Methods: Aorta magnetic resonance imaging was performed in 21 healthy volunteers at a 1.5t MR scanner sequences including cardiac-gated and peripheral pulse-gated True-FISP and HASTE were carried out separately. Acquisition Time (TA), Signal to Noise Ratio (SNR), Contrast Noise Ratio (CNR), and entirety of vessel wall blood flow artifacts were measured and compared. A total of 56 AD cases were displayed by non-enhancement peripheral pulse-gating fast MR imaging, and the results were compared with pathological findings or CTA of the aorta. The dissection rupture, tear film, true and false lumen, thrombosis, hydropericardium, and the main branches of AD were evaluated respectively. Results: There were no significant differences in SNR, CNR, entirety of the vessel wall, and blood flow artifact between cardiac-gated and peripheral pulse-gated fast MR imaging. Non-enhancement pulse-gated fast scanning takes less TA time. By the pulse-gated non-enhancement fast MR imaging, the dissection rupture, tear film, true and false cavity, thrombosis, hydropericardium, and the main branches of aortic dissection were shown clearly. Multi-planar and multi-angle scans helped to show the extent of entrapment rupture, whereas partial complex tears or bi-directional tears were slightly less well visualized. Conclusion: Non-enhancement peripheral pulse-gated rapid magnetic resonance imaging can be used for deterministic diagnosis of AD.