Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Intervalo de año de publicación
1.
Int J Clin Oncol ; 29(6): 735-743, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38649649

RESUMEN

BACKGROUND: Photoimmunotherapy is a treatment modality that induces targeted cell death by binding a molecular-targeted drug activated by infrared light to the tumor cells and subsequently illuminating the lesion with infrared light. For deep lesions, a needle catheter is used to puncture the tumor, and an illumination fiber (cylindrical diffuser) is inserted into the catheter lumen for internal illumination. However, it can be challenging to place the cylindrical diffusers in an appropriate position as the deep lesions cannot be often confirmed accurately during surgery. MATERIALS AND METHODS: We have developed "SlicerPIT", a planning simulation software for photoimmunotherapy. SlicerPIT allows users to place the cylindrical diffuser with its illumination range on preoperative images in 2D and 3D and export the planning data to external image-guided surgical navigation systems. We performed seven cycles of photoimmunotherapy with SlicerPIT in three patients with recurrent head and neck cancer. RESULTS: Preoperative planning for photoimmunotherapy was conducted using SlicerPIT, which could be imported into the navigation system. During the operation, we punctured the needle catheters along with the treatment plan on the navigation screen. Subsequently, intraoperative CT imaging was performed and overlaid with the preoperative treatment plan to confirm the alignment of the cylindrical diffusers as planned, followed by infrared light illumination. Postoperative imaging showed necrosis and shrinkage of the entire tumor in all cycles. CONCLUSION: SlicerPIT allows for detailed preoperative treatment planning and accurate puncture. It may be a valuable tool to improve the accuracy of photoimmunotherapy for deep lesions and improve patient outcomes.


Asunto(s)
Inmunoterapia , Programas Informáticos , Humanos , Inmunoterapia/métodos , Neoplasias de Cabeza y Cuello/terapia , Neoplasias de Cabeza y Cuello/radioterapia , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X , Fototerapia/métodos , Rayos Infrarrojos/uso terapéutico
2.
Phys Imaging Radiat Oncol ; 28: 100510, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38054031

RESUMEN

In this study, we evaluated a novel 16-bit computed tomography (CT) system optimized for radiotherapy planning. Over six months, using various protocols, we conducted 616 scans, with an average of four CT series per session imported into our treatment planning software (TPS). The direct density (DD) reconstruction enabled a single CT number calibration curve for multiple tube voltages. Metal artifacts could be effectively reduced. The 16-bit character permitted dose calculation in high-density regions, while TPS integration challenges remained. In conclusion, our findings emphasize the system's potential benefits and considerations in radiotherapy workflows.

3.
Med Phys ; 50(11): 6684-6692, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37816130

RESUMEN

BACKGROUND: Administration of external radiation therapy via proton therapy systems carries a risk of occasional collisions between the patient's body and gantry, which is increased by the snout placed near the patient for better dose distribution. Although treatment planning software (TPS) can simulate controlled collisions, the computed tomography (CT) data used for treatment planning are insufficient given that collisions can occur outside the CT imaging region. Thus, imaging the three-dimensional (3D) surface outside the CT range and combining the data with those obtained by CT are essential for avoiding collisions. PURPOSE: To construct a prototype for 3D surface imaging and an end-to-end framework for preventing collisions between the patient's body and the gantry. METHODS: We obtained 3D surface data using a light sectioning method (LSM). By installing only cameras in front of the CT, we achieved LSM using the CT couch motion and preinstalled patient-positioning lasers. The camera image contained both sagittal and coronal lines, which are unnecessary for LSM and were removed by deep learning. We combined LSM 3D surface data and original CT data to create synthetic Digital Imaging and Communications in Medicine (DICOM) data. Subsequently, we compared the TPS snout auto-optimization using the original CT data with the synthetic DICOM data. RESULTS: The mean positional error for LSM of the arms and head was 0.7 ± 0.8  and 0.8 ± 0.8 mm for axial and sagittal imaging, respectively. The TPS snout auto-optimization indicated that the original CT data would cause collisions; however, the synthetic DICOM data prevented these collisions. CONCLUSIONS: The prototype system's acquisition accuracy for 3D surface data was approximately 1 mm, which was sufficient for the collision simulation. The use of a TPS with collision avoidance can help optimize the snout position using synthetic DICOM data. Our proposed method requires no external software for collision simulation and can be integrated into the clinical workflow to improve treatment planning efficiency.


Asunto(s)
Terapia de Protones , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Programas Informáticos , Simulación por Computador , Tomografía Computarizada por Rayos X
4.
Int J Hyperthermia ; 40(1): 2218627, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37455017

RESUMEN

INTRODUCTION: Hyperthermic IntraPEritoneal Chemotherapy (HIPEC) aims to treat microscopic disease left after CytoReductive Surgery (CRS). Thermal enhancement depends on the temperatures achieved. Since the location of microscopic disease is unknown, a homogeneous treatment is required to completely eradicate the disease while limiting side effects. To ensure homogeneous delivery, treatment planning software has been developed. This study compares simulation results with clinical data and evaluates the impact of nine treatment strategies on thermal and drug distributions. METHODS: For comparison with clinical data, three treatment strategies were simulated with different flow rates (1600-1800mL/min) and inflow temperatures (41.6-43.6 °C). Six additional treatment strategies were simulated, varying the number of inflow catheters, flow direction, and using step-up and step-down heating strategies. Thermal homogeneity and the risk of thermal injury were evaluated. RESULTS: Simulated temperature distributions, core body temperatures, and systemic chemotherapeutic concentrations compared well with literature values. Treatment strategy was found to have a strong influence on the distributions. Additional inflow catheters could improve thermal distributions, provided flow rates are kept sufficiently high (>500 mL/min) for each catheter. High flow rates (1800 mL/min) combined with high inflow temperatures (43.6 °C) could lead to thermal damage, with CEM4310 values of up to 27 min. Step-up and step-down heating strategies allow for high temperatures with reduced risk of thermal damage. CONCLUSION: The planning software provides valuable insight into the effects of different treatment strategies on peritoneal distributions. These strategies are designed to provide homogeneous treatment delivery while limiting thermal injury to normal tissue, thereby optimizing the effectiveness of HIPEC.


Asunto(s)
Hipertermia Inducida , Neoplasias Peritoneales , Humanos , Quimioterapia Intraperitoneal Hipertérmica , Terapia Combinada , Hipertermia Inducida/métodos , Neoplasias Peritoneales/tratamiento farmacológico , Neoplasias Peritoneales/cirugía , Quimioterapia del Cáncer por Perfusión Regional/métodos , Procedimientos Quirúrgicos de Citorreducción/métodos
5.
Front Oncol ; 13: 1102242, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36865797

RESUMEN

Introduction: CytoReductive Surgery (CRS) followed by Hyperthermic IntraPeritoneal Chemotherapy (HIPEC) is an often used strategy in treating patients diagnosed with peritoneal metastasis (PM) originating from various origins such as gastric, colorectal and ovarian. During HIPEC treatments, a heated chemotherapeutic solution is circulated through the abdomen using several inflow and outflow catheters. Due to the complex geometry and large peritoneal volume, thermal heterogeneities can occur resulting in an unequal treatment of the peritoneal surface. This can increase the risk of recurrent disease after treatment. The OpenFoam-based treatment planning software that we developed can help understand and map these heterogeneities. Methods: In this study, we validated the thermal module of the treatment planning software with an anatomically correct 3D-printed phantom of a female peritoneum. This phantom is used in an experimental HIPEC setup in which we varied catheter positions, flow rate and inflow temperatures. In total, we considered 7 different cases. We measured the thermal distribution in 9 different regions with a total of 63 measurement points. The duration of the experiment was 30 minutes, with measurement intervals of 5 seconds. Results: Experimental data were compared to simulated thermal distributions to determine the accuracy of the software. The thermal distribution per region compared well with the simulated temperature ranges. For all cases, the absolute error was well below 0.5°C near steady-state situations and around 0.5°C, for the entire duration of the experiment. Discussion: Considering clinical data, an accuracy below 0.5°C is adequate to provide estimates of variations in local treatment temperatures and to help optimize HIPEC treatments.

6.
Int J Hyperthermia ; 38(1): 38-54, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33487083

RESUMEN

BACKGROUND: Hyperthermic intraperitoneal chemotherapy (HIPEC) is administered to treat residual microscopic disease after cytoreductive surgery (CRS). During HIPEC, fluid (41-43 °C) is administered and drained through a limited number of catheters, risking thermal and drug heterogeneities within the abdominal cavity that might reduce effectiveness. Treatment planning software provides a unique tool for optimizing treatment delivery. This study aimed to investigate the influence of treatment-specific parameters on the thermal and drug homogeneity in the peritoneal cavity in a computed tomography based rat model. METHOD: We developed computational fluid dynamics (CFD) software simulating the dynamic flow, temperature and drug distribution during oxaliplatin based HIPEC. The influence of location and number of catheters, flow alternations and flow rates on peritoneal temperature and drug distribution were determined. The software was validated using data from experimental rat HIPEC studies. RESULTS: The predicted core temperature and systemic oxaliplatin concentration were comparable to the values found in literature. Adequate placement of catheters, additional inflow catheters and higher flow rates reduced intraperitoneal temperature spatial variation by -1.4 °C, -2.3 °C and -1.2 °C, respectively. Flow alternations resulted in higher temperatures (up to +1.5 °C) over the peritoneal surface. Higher flow rates also reduced the spatial variation of chemotherapy concentration over the peritoneal surface resulting in a more homogeneous effective treatment dose. CONCLUSION: The presented treatment planning software provides unique insights in the dynamics during HIPEC, which enables optimization of treatment-specific parameters and provides an excellent basis for HIPEC treatment planning in human applications.


Asunto(s)
Hipertermia Inducida , Quimioterapia Intraperitoneal Hipertérmica , Animales , Terapia Combinada , Procedimientos Quirúrgicos de Citorreducción , Oxaliplatino , Peritoneo , Ratas , Programas Informáticos
7.
Drug Deliv ; 28(1): 145-161, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33427507

RESUMEN

Hyperthermic intraperitoneal chemotherapy (HIPEC) is administered to treat residual microscopic disease after debulking cytoreductive surgery. During HIPEC, a limited number of catheters are used to administer and drain fluid containing chemotherapy (41-43 °C), yielding heterogeneities in the peritoneum. Large heterogeneities may lead to undertreated areas, increasing the risk of recurrences. Aiming at intra-abdominal homogeneity is therefore essential to fully exploit the potential of HIPEC. More insight is needed into the extent of the heterogeneities during treatments and assess their effects on the efficacy of HIPEC. To that end we developed a computational model containing embedded tumor nodules in an environment mimicking peritoneal conditions. Tumor- and treatment-specific parameters affecting drug delivery like tumor size, tumor shape, velocity, temperature and dose were assessed using three-dimensional computational fluid dynamics (CFD) to demonstrate their effect on the drug distribution and accumulation in nodules. Clonogenic assays performed on RKO colorectal cell lines yielded the temperature-dependent IC50 values of cisplatin (19.5-6.8 micromolar for 37-43 °C), used to compare drug distributions in our computational models. Our models underlined that large nodules are more difficult to treat and that temperature and velocity are the most important factors to control the drug delivery. Moderate flow velocities, between 0.01 and 1 m/s, are optimal for the delivery of cisplatin. Furthermore, higher temperatures and higher doses increased the effective penetration depth with 69% and 54%, respectively. We plan to extend the software developed for this study toward patient-specific treatment planning software, capable of mapping and assist in reducing heterogeneous flow patterns.


Asunto(s)
Antineoplásicos/administración & dosificación , Cisplatino/administración & dosificación , Neoplasias Colorrectales/tratamiento farmacológico , Hidrodinámica , Quimioterapia Intraperitoneal Hipertérmica/métodos , Neoplasias Peritoneales/tratamiento farmacológico , Temperatura , Línea Celular Tumoral , Neoplasias Colorrectales/patología , Simulación por Computador , Humanos , Concentración 50 Inhibidora , Neoplasias Peritoneales/secundario , Carga Tumoral
8.
Cancer Manag Res ; 7: 345-56, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26648755

RESUMEN

RapidArc™ is a radiation technique that delivers highly conformal dose distributions through the complete rotation (360°) and speed variation of the linear accelerator gantry. This technique, called volumetric modulated arc therapy (VMAT), compared with conventional radiotherapy techniques, can achieve high-target volume coverage and sparing damage to normal tissues. RapidArc delivers precise dose distribution and conformity similar to or greater than intensity-modulated radiation therapy in a short time, generally a few minutes, to which image-guided radiation therapy is added. RapidArc has become a currently used technology in many centers, which use RapidArc technology to treat a large number of patients. Large and small hospitals use it to treat the most challenging cases, but more and more frequently for the most common cancers. The clinical use of RapidArc and VMAT technology is constantly growing. At present, a limited number of clinical data are published, mostly concerning planning and feasibility studies. Clinical outcome data are increasing for a few tumor sites, even if only a little. The purpose of this work is to discuss the current status of VMAT techniques in clinical use through a review of the published data of planning systems and clinical outcomes in several tumor sites. The study consisted of a systematic review based on analysis of manuscripts retrieved from the PubMed, BioMed Central, and Scopus databases by searching for the keywords "RapidArc", "Volumetric modulated arc radiotherapy", and "Intensity-modulated radiotherapy".

9.
Rep Pract Oncol Radiother ; 18(6): 383-6, 2013 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-24416583

RESUMEN

AIM/BACKGROUND: To evaluate how the use of volumetric-modulated arc therapy (VMAT) with RapidArc(®) can improve treatment delivery efficiency based on the analysis of the beam-on times and monitor units (MU) needed to deliver therapy for multiple clinical applications in a large patient population. MATERIALS AND METHODS: A total of 898 treatment courses were delivered in 745 patients treated from October 2008 to March 2013 using RapidArc® treatment plans generated in Eclipse™ TPS. All patients were treated with curative or palliative intent using different techniques including conventional fractionation (83%) and radiosurgery or SBRT (17%), depending on the clinical indications. Treatment delivery was evaluated based on measured beam-on time and recorded MU values delivered on a Varian Trilogy™ linear accelerator. RESULTS: For conventional fractionation treatments using RapidArc®, the delivery times ranged from 38 s to 4 min and 40 s (average 2 min and 6 s). For radiosurgical treatments the delivery times ranged from 1 min and 42 s to 9 min and 22 s (average 4 min and 4 s). The average number of MU per Gy was 301 for the entire group, with 285 for the conventional group and 317 for the radiosurgical group. CONCLUSIONS: In this study with a large heterogeneous population, treatments using RapidArc® were delivered with substantially less beam-on time and fewer MUs than conventional fractionation. This was highly advantageous, increasing flexibility of the scheduling allowing treatment of radiosurgery patients during the regular daily work schedule. Additionally, reduction of leakage radiation dose was achieved.

10.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-26300

RESUMEN

In brachytherapy of uterine cervical cancer using the high dose rate remote afterloading system, it is of prime importance to determine the position of the radiation sources and to estimate the irradiation time. However, calculation with manual method is so time consuming and laborious, that authors designed a software as an aid to intracavitary radiotherapy planning using the personal computer to obtain the precision of treatment without being too complicated for routine use. Optimal source arrangement in combination with dose rate at each specific points and irradiation time can be easily determined using this software in several minutes.


Asunto(s)
Braquiterapia , Microcomputadores , Radioterapia , Neoplasias del Cuello Uterino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA