J Prosthodont ; 31(2): 136-146, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33870577

RESUMEN

PURPOSE: This laboratory study analyzed the influence of retention mode (screw- vs cement retained) and fatigue application on the failure load of monolithic lithium-disilicate (LDS) implant-supported single crowns (ISSC). MATERIAL AND METHODS: A total of 72 samples of monolithic LDS (*Ivoclar Vivadent) ISSC were divided into three groups (n = 24) according to their type of retention mode: Group Ti-CAD: Titanium base (SICvantage CAD/CAM Abutment red (SIC invent AG), screw-retained milled monolithic LDS (IPS e.max CAD*); Group Ti-P: Titanium base (SICvantage CAD/CAM Abutment red), screw-retained pressed monolithic LDS (IPS e.max Press*) and Group Ti-Cust: Titanium base with cemented press LDS (IPS e.max Press*) crown on a LDS (IPS e.max Press*) custom abutment. A mandibular first molar implant-supported single crown model was investigated (Titanium implant: SICvantage-max, SIC invent AG, diameter: 4.2 mm, length: 11.5 mm). Half of each group (n = 12) w​ere exposed to fatigue with cyclic mechanical loading (F = 198 N, 1.2 million cycles) and simultaneous thermocycling (5-55°C). Single load to failure testing was performed, before (Subgroups Ti-CAD, Ti-P, and Ti-Cust) and after (Subgroups Ti-CAD-F, Ti-P-F, and Ti-Cust-F) fatigue. Weibull distribution was used to determine the characteristic strength and Weibull modulus differences between groups. Probability of survival at 900N load was calculated. RESULTS: No samples failed during fatigue. Characteristic strength values were as follow: Ti-CAD: 3259.5N, Ti-CAD-F: 2926N, Ti-P: 2763N, Ti-P-F: 2841N, Ti-Cust: 2789N, Ti-Cust-F: 2194N. Whereas no difference was observed between pressed or milled monolithic crowns cemented to Ti-base, regardless of loading condition, fatigue decreased the characteristic strength of crowns cemented to custom abutments. Probability of survival at 900 N was not significantly different between groups. CONCLUSIONS: Screw-retained pressed or milled monolithic LDS ISSC, cemented directly to Ti-base abutments or LDS crowns cemented to custom ceramic abutments resist physiological chewing forces after simulated 5-year aging in the artificial mouth and presented equally high probability of survival. However, a significant decrease in load to failure was observed in LDS crowns cemented to custom ceramic abutments after fatigue. Prospective clinical trials are needed to confirm the results of this laboratory investigation.


Asunto(s)
Implantes Dentales , Ensayo de Materiales , Titanio , Cerámica , Diseño Asistido por Computadora , Coronas , Pilares Dentales , Porcelana Dental , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Humanos , Estudios Prospectivos
2.
Materials (Basel) ; 14(24)2021 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-34947134

RESUMEN

To evaluate the failure-load and survival-rate of screw-retained monolithic and bi-layered crowns bonded to titanium-bases before and after mouth-motion fatigue, 72 titanium-implants (SICvantage-max, SIC-invent-AG) were restored with three groups (n = 24) of screw-retained CAD/CAM implant-supported-single-crowns (ISSC) bonded to titanium-bases: porcelain-fused-to-metal (PFM-control), porcelain-fused-to-zirconia (PFZ-test) and monolithic LDS (LDS-test). Half of the specimens (n = 12/group) were subjected to fatigue in a chewing-simulator (1.2 million cycles, 198 N, 1.67 Hz, thermocycling 5-55 °C). All samples were exposed to single-load-to-failure without (PFM0, PFZ0, LDS0) or with fatigue (PFM1, PFZ1, LDS1). Comparisons were statistically analyzed with t-tests and regression-models and corrected for multiple-testing using the Student-Neuman-Keuls method. All PFM and LDS crowns survived fatigue exposure, whereas 16.7% of PFZ showed chipping failures. The mean failure-loads (±SD) were: PFM0: 2633 ± 389 N, PFM1: 2349 ± 578 N, PFZ0: 2152 ± 572 N, PFZ1: 1686 ± 691 N, LDS0: 2981 ± 798 N, LDS1: 2722 ± 497 N. Fatigue did not influence load to failure of any group. PFZ ISSC showed significantly lower failure-loads than monolithic-LDS regardless of artificial aging (p < 0.05). PFM ISSC showed significantly higher failure loads after fatigue than PFZ (p = 0.032). All ISSC failed in a range above physiological chewing forces. Premature chipping fractures might occur in PFZ ISSC. Monolithic-LDS ISSC showed high reliability as an all-ceramic material for screw-retained posterior hybrid-abutment-crowns.

3.
Materials (Basel) ; 13(14)2020 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-32708937

RESUMEN

Two-piece abutments consisting of customized zirconia abutment copings and prefabricated titanium bases are popular due to their biological and esthetic advantages. Glass-ceramic solder (GS) is an alternative biocompatible connective agent. This in vitro study evaluated the retentive force of GS in comparison to classical resin composite cements (RC) after artificial aging and autoclaving. Ninety specimens consisting of prefabricated titanium bases and zirconia abutment copings were fabricated. The two parts of each specimen were fixed either by RC (n = 30) or GS with a luting space of either 30 µm (n = 30) or 100 µm (n = 30). Ten specimens of each group underwent autoclaving before artificial aging (water storage, thermocycling). Twenty specimens (including the 10 autoclaved specimens) of each group were exposed to a mechanical load. The retentive force between the zirconia and titanium in all specimens was determined. A fractographic analysis was performed to analyze the fracture surfaces of the GS specimens. The RC- and GS-connected two-piece abutments showed no relevant differences, independent of the luting space. RC appears to be more vulnerable to the thermal and mechanical loads than GS. Thus, GS may be an appropriate alternative to RC for two-piece abutments, especially for patients with enhanced biocompatibility requirements.

4.
Clin Oral Implants Res ; 30(1): 90-98, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30521070

RESUMEN

OBJECTIVE: The purpose of this laboratory study was to evaluate the fatigue resistance, fracture resistance and mode of failure of posterior hybrid-abutment-crown vs. hybrid-abutment with separate crown, both bonded to short titanium bases. MATERIALS AND METHODS: Thirty-two titanium implants were embedded perpendicularly in auto-polymerizing resin. Implant-supported restorations simulating a maxillary first premolar were designed and milled using a CAD/CAM system and divided into 2 groups according to material (n = 16): zirconia (Z) and lithium disilicate (L). Each group was subdivided into two subgroups according to design (n = 8): hybrid-abutment-crown (ZS, LS) and hybrid-abutment with separate crown (ZC, LC). Each group was subjected to 1.2 million cycles of thermo-mechanical fatigue loading in a dual-axis chewing simulator at 120 N load. Surviving specimens were subjected to quasi-static loading in a universal testing machine. Mode of failure was determined under a low magnification optical microscope. RESULTS: During chewing simulation, 18.8% of zirconia and 43.8% of lithium disilicate restorations failed. The fracture resistance median values ranged from 3,730 N for group ZC, 3,400 N for group ZS, 1,295 N for group LS to 849 N for group LC. Group ZC had a statistically significant higher fracture resistance than groups LC and LS; however, it did not differ significantly from group ZS (p ≤ 0.05). Failures were seen in both titanium bases and ceramic superstructure. CONCLUSIONS: Zirconia and lithium disilicate hybrid implant-supported restorations with short (3 mm) titanium bases failed in a considerable number already during chewing simulation. Therefore, despite their high fracture strength the use in the posterior region should be considered critically.


Asunto(s)
Coronas , Pilares Dentales , Diseño de Implante Dental-Pilar , Implantes Dentales , Porcelana Dental , Humanos , Ensayo de Materiales , Titanio , Circonio
5.
Int J Comput Dent ; 21(2): 163-171, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29967907

RESUMEN

The development of titanium bonding bases allows for the use of implant-supported monolithic reconstructions in a digital workflow. Different base configurations are available according to each clinical indication. In this case report, the selection of titanium bonding bases for crowns was considered for a multiple-unit fixed dental prosthesis (FDP).


Asunto(s)
Recubrimiento Dental Adhesivo , Prótesis Dental de Soporte Implantado , Titanio , Circonio , Anciano , Diseño Asistido por Computadora , Femenino , Humanos , Arcada Parcialmente Edéntula