1.
Sensors (Basel) ; 24(16)2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39205073

RESUMEN

Time of flight is promising technology in machine vision and sensing, with an emerging need for low power consumption, a high image resolution, and reliable operation in high ambient light conditions. Therefore, we propose a novel direct time-of-flight pixel using the single-photon avalanche diode (SPAD) sensor, with an in-pixel averaging method to suppress ambient light and detect the laser pulse arrival time. The system utilizes two orthogonal sinusoidal signals applied to the pixel as inputs, which are synchronized with a pulsed laser source. The detected signal phase indicates the arrival time. To evaluate the proposed system's potential, we developed analytical and statistical models for assessing the phase error and precision of the arrival time under varying ambient light levels. The pixel simulation showed that the phase precision is less than 1% of the detection range when the ambient-to-signal ratio is 120. A proof-of-concept pixel array prototype was fabricated and characterized to validate the system's performance. The pixel consumed, on average, 40 µW of power in operation with ambient light. The results demonstrate that the system can operate effectively under varying ambient light conditions and its potential for customization based on specific application requirements. This paper concludes by discussing the system's performance relative to the existing direct time-of-flight technologies, identifying their strengths and limitations.

2.
EJNMMI Phys ; 11(1): 73, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39174856

RESUMEN

OBJECTIVE: Positron Emission Tomography (PET) is a well-known imaging technology for the diagnosis, treatment, and monitoring of several diseases. Most PET scanners use a Ring-Shaped Detector Configuration (RSDC), which helps obtain homogeneous image quality but are restricted to an invariable Field-of-View (FOV), scarce spatial resolution, and low sensitivity. Alternatively, few PET systems use Open Detector Configurations (ODC) to permit an accessible FOV adaptable to different target sizes, thus optimizing sensitivity. Yet, to compensate the lack of angular coverage in ODC-PET, developing a detector with high-timing performance is mandatory to enable Time-of-Flight (TOF) techniques during reconstruction. The main goal of this work is to provide a proof of concept PET scanner appropriate for constructing the new generation of ODC-PET suitable for biopsy guidance and clinical intervention during acquisition. The designed detector has to be compact and robust, and its requirements in terms of performance are spatial and time resolutions < 2 mm and < 200 ps, respectively. METHODS: The present work includes a simulation study of an ODC-PET based on 2-panels with variable distance. The image quality (IQ) and Derenzo phantoms have been simulated and evaluated. The phantom simulations have also been performed using a ring-shaped PET for comparison purposes of the ODC approach with conventional systems. Then, an experimental evaluation of a prototype detector that has been designed following the simulation results is presented. This study focused on tuning the ASIC parameters and evaluating the scintillator surface treatment (ESR and TiO2), and configuration that yields the best Coincidence Time Resolution (CTR). Moreover, the scalability of the prototype to a module of 64 × 64mm2 and its preliminary evaluation regarding pixel identification are provided. RESULTS: The simulation results reported sensitivity (%) values at the center of the FOV of 1.96, 1.63, and 1.18 for panel distances of 200, 250, and 300 mm, respectively. The IQ reconstructed image reported good uniformity (87%) and optimal CRC values, and the Derenzo phantom reconstruction suggests a system resolution of 1.6-2 mm. The experimental results demonstrate that using TiO2 coating yielded better detector performance than ESR. Acquired data was filtered by applying an energy window of ± 30% at the photopeak level. After filtering, best CTR of 230 ± 2 ps was achieved for an 8 × 8 LYSO pixel block with 2 × 2 × 12mm3 each. The detector performance remained constant after scaling-up the prototype to a module of 64 × 64mm2, and the flood map demonstrates the module's capabilities to distinguish the small pixels; thus, a spatial resolution < 2 mm (pixel size) is achieved. CONCLUSIONS: The simulated results of this biplanar scanner show high performance in terms of image quality and sensitivity. These results are comparable to state-of-the-art PET technology and, demonstrate that including TOF information minimizes the image artifacts due to the lack of angular projections. The experimental results concluded that using TiO2 coating provide the best performance. The results suggest that this scanner may be suitable for organ study, breast, prostate, or cardiac applications, with good uniformity and CRC.

3.
Quant Imaging Med Surg ; 14(4): 2788-2799, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38617180

RESUMEN

Background: Color Doppler ultrasonography (CDUS) is feasible to detect arteriovenous fistula (AVF) dysfunction in hemodialysis patients but is not sufficient to map the structure of fistula required for interventions. This study is designed to evaluate the diagnostic accuracy of three-dimensional time-of-flight magnetic resonance angiography (TOF-MRA) at 3.0T versus CDUS for AVF dysfunction, by using digital subtraction angiography (DSA) as reference. Methods: This prospective study enrolled 68 consecutive patients with dysfunctional AVF who underwent both CDUS and TOF-MRA at Shanghai Sixth People's Hospital affiliated to Shanghai Jiao Tong University School of Medicine. The analysis of the dysfunctional AVFs was divided into three regions: the feeding artery, fistula and draining veins. In the whole- and per-regional-based analyses, two observers who were blinded to the clinical and DSA results independently analyzed all CDUS and TOF-MRA datasets. The image quality and stenosis severity of the lesions on TOF-MRA were evaluated. A receiver operating characteristic curve was applied to analyze the detection of AVF dysfunction with TOF-MRA. Results: A total of 204 vessel regions were evaluated. The whole-region-based image quality of TOF-MRA was poorer in patients with a total occlusion (1.8±0.8) than in those with stenosis (2.7±0.6, P<0.001). In the whole-region analyses, TOF-MRA had higher sensitivity [99.1% (94.6-100.0%) vs. 82.9% (74.6-89.0%), P<0.001] and similar specificity [93.1% (85.0-97.1%) vs. 94.3% (86.5-97.9%), P=0.755] than CDUS. The per-region-based analyses showed that TOF-MRA yielded higher sensitivity [fistula region, 98.1% (88.4-99.9%) vs. 80.8% (67.0-89.9%); P=0.004; draining vein region, 100.0% (92.5-100.0%) vs. 85.0% (72.9-2.5%); P=0.003] and similar specificity [fistula region, 88.2% (62.3-97.8%) vs. 88.2% (62.3-97.9%); P>0.99; draining vein region, 100.0% (59.8-100.0%) vs. 87.5% (46.7-99.3%); P>0.99] than CDUS. Sensitivity and specificity of TOF-MRA were comparable to those of CDUS in feeding artery region. Conclusions: TOF-MRA is a feasible and accurate method to display AVF dysfunction in hemodialysis patients, and this method might fulfill the endovascular treatment planning requirements.

4.
Phys Med Biol ; 69(2)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38181423

RESUMEN

Objective. We propose a single-ended readout, multi-resolution detector design that can achieve high spatial, depth-of-interaction (DOI), and time-of-flight (TOF) resolutions, as well as high sensitivity for human brain-dedicated positron emission tomography (PET) scanners.Approach. The detector comprised two layers of LYSO crystal arrays and a lightguide in between. The top (gamma ray entrance) layer consisted of a 16 × 16 array of 1.53 × 1.53 × 6 mm3LYSO crystals for providing high spatial resolution. The bottom layer consisted of an 8 × 8 array of 3.0 × 3.0 × 15 mm3LYSO crystals that were one-to-one coupled to an 8 × 8 multipixel photon counter (MPPC) array for providing high TOF resolution. The 2 mm thick lightguide introduces inter-crystal light sharing that causes variations of the light distribution patterns for high DOI resolution. The detector was read out by a PETsys TOFPET2 application-specific integrated circuit.Main result. The top and bottom layers were distinguished by a convolutional neural network with 97% accuracy. All crystals in the top and bottom layers were resolved. The inter-crystal scatter (ICS) events in the bottom layer were identified, and the measured average DOI resolution of the bottom layer was 4.1 mm. The coincidence time resolution (CTR) for the top-top, top-bottom, and bottom-bottom coincidences was 476 ps, 405 ps, and 298 ps, respectively. When ICS events were excluded from the bottom layer, the CTR of the bottom-bottom coincidence was 277 ps.Significance. The top layer of the proposed two-layer detector achieved a high spatial resolution and the bottom layer achieved a high TOF resolution. Together with its high DOI resolution and detection efficiency, the proposed detector is well suited for next-generation high-performance brain-dedicated PET scanners.


Asunto(s)
Encéfalo , Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen , Fotones , Rayos gamma
5.
Phys Med Biol ; 69(2)2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38091614

RESUMEN

Objective. The high production cost of commonly used lutetium-based fast scintillators and the development of silicon photomultipliers technology have made bismuth germanate (BGO) a promising candidate for time-of-flight positron emission tomography (TOF PET) detectors owing to its generation of prompt Cherenkov photons. However, using BGO as a hybrid scintillator is disadvantageous owing to its low photon statistics and distribution that does not conform well to a single Gaussian. To mitigate this, a proposal was made to increase the likelihood of detecting the first Cherenkov photons by positioning two photosensors in opposition at the entrance and exit faces of the scintillator and subsequently selectively picking an earlier timestamp. Nonetheless, the timing variation arising from the photon transit time remains affected by the entire length of the crystal, thereby presenting a possibility for further enhancement.Approach. In this study, we aimed to improve the timing performance of the dual-ended BGO Cherenkov TOF PET detector by capitalizing on the synergistic advantages of applying depth-of-interaction (DOI) information and crystal surface finishes or reflector properties. A dual-ended BGO detector was implemented using a 3 × 3 × 15 mm3BGO crystal. Coincidence events were acquired against a 3 × 3 × 3 mm3LYSO:Ce:Mg reference detector. The timing performance of the dual-ended BGO detectors was analyzed using conventionally proposed timestamp methods before and after DOI correction.Results. Through a DOI-based correction of photon transit time spread, we demonstrated a further improvement in the timing resolution of the BGO-based Cherenkov TOF PET detector utilizing a dual-ended detector configuration and adaptive arrival time pickoff. We achieved further improvements in timing resolution by correcting the offset spread induced by the fluctuation of timing signal rise time in the dual-ended detector.Significance. Although polishing the crystal surface was still favorable in terms of full-width-half-maximum value, incorporating DOI information from the unpolished crystal to compensate for photon travel time facilitated additional enhancement in the overall timing performance, thereby surpassing that achieved with the polished crystal.


Asunto(s)
Fotones , Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Lutecio , Conteo por Cintilación
6.
Nano Lett ; 23(12): 5535-5540, 2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37328157

RESUMEN

A large and growing number of applications benefit from innovative and powerful 3D image sensors. Graphene photodetectors can achieve 3D sensing functionalities by intrinsic optoelectronic frequency mixing due to the nonlinear output characteristics of the sensor. In first proof of principle distance measurement demonstrations, we achieve modulation frequencies of 3.1 MHz, signal-to-noise ratios of ∼40 dB, distance detection up to at least 1 m, and a mean accuracy of 25.6 mm. The scalable More than Moore detector approach enables geometrical fill factors close to 100% and can easily complement powerful functionalities by simple back-end integration on top of CMOS electronics.

7.
Sensors (Basel) ; 23(8)2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-37112329

RESUMEN

This paper presents a time-of-flight image sensor based on 8-Tap P-N junction demodulator (PND) pixels, which is designed for hybrid-type short-pulse (SP)-based ToF measurements under strong ambient light. The 8-tap demodulator implemented with multiple p-n junctions used for modulating the electric potential to transfer photoelectrons to eight charge-sensing nodes and charge drains has an advantage of high-speed demodulation in large photosensitive areas. The ToF image sensor implemented using 0.11 µm CIS technology, consisting of an 120 (H) × 60 (V) image array of the 8-tap PND pixels, successfully works with eight consecutive time-gating windows with the gating width of 10 ns and demonstrates for the first time that long-range (>10 m) ToF measurements under high ambient light are realized using single-frame signals only, which is essential for motion-artifact-free ToF measurements. This paper also presents an improved depth-adaptive time-gating-number assignment (DATA) technique for extending the depth range while having ambient-light canceling capability and a nonlinearity error correction technique. By applying these techniques to the implemented image sensor chip, hybrid-type single-frame ToF measurements with depth precision of maximally 16.4 cm (1.4% of the maximum range) and the maximum non-linearity error of 0.6% for the full-scale depth range of 1.0-11.5 m and operations under direct-sunlight-level ambient light (80 klux) have been realized. The depth linearity achieved in this work is 2.5 times better than that of the state-of-the-art 4-tap hybrid-type ToF image sensor.

8.
Sensors (Basel) ; 23(8)2023 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-37112360

RESUMEN

The ranging accuracy of pulsed time-of-flight (TOF) lidar is affected by walk error and jitter error. To solve the issue, the balanced detection method (BDM) based on fiber delay optic lines (FDOL) is proposed. The experiments are carried out to prove the performance improvement of BDM over the conventional single photodiode method (SPM). The experimental results show that BDM can suppress common mode noise and simultaneously shift the signal to high frequency, which reduces the jitter error by approximately 52.4% and maintains the walk error at less than 300 ps with a non-distorted waveform. The BDM can be further applied to silicon photomultipliers.

9.
Sensors (Basel) ; 23(6)2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36992035

RESUMEN

We demonstrate a methodology for non-contact classification of five different plastic types using an inexpensive direct time-of-flight (ToF) sensor, the AMS TMF8801, designed for consumer electronics. The direct ToF sensor measures the time for a brief pulse of light to return from the material with the intensity change and spatial and temporal spread of the returned light conveying information on the optical properties of the material. We use measured ToF histogram data of all five plastics, captured at a range of sensor to material distances, to train a classifier that achieves 96% accuracy on a test dataset. To extend the generality and provide insight into the classification process, we fit the ToF histogram data to a physics-based model that differentiates between surface scattering and subsurface scattering. Three optical parameters of the ratio of direct to subsurface intensity, the object distance, and the time constant of the subsurface exponential decay are used as features for a classifier that achieves 88% accuracy. Additional measurements at a fixed distance of 22.5 cm showed perfect classification and revealed that Poisson noise is not the most significant source of variation when measurements are taken over a range of object distances. In total, this work proposes optical parameters for material classification that are robust over object distance and measurable by miniature direct time-of-flight sensors designed for installation in smartphones.

10.
Sensors (Basel) ; 23(5)2023 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-36904936

RESUMEN

The purpose of this work is to prove the suitability of integrated single-photon avalanche diode (SPAD)-based indirect time-of-flight (iTOF) for sub-100 µm precision depth sensing using a correlation approach with GHz modulation frequencies. For this purpose, a prototype containing a single pixel consisting of an integrated SPAD, quenching circuit, and two independent correlator circuits was fabricated in a 0.35 µm CMOS process and characterized. It achieved a precision of 70 µm and a nonlinearity of less than 200 µm at a received signal power of less than 100 pW. Sub-mm precision was achieved with a signal power of less than 200 fW. These results and the simplicity of our correlation approach underline the great potential of SPAD-based iTOF for future depth sensing applications.

11.
Hemoglobin ; 46(2): 81-86, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35957560

RESUMEN

We report the identification of a novel hemoglobin (Hb) variant [α57(E6)Gly→Cys; HBA1: c.172G>T], to be referred to as Hb Kirikiriroa. The variant was detected in five subjects from two families, with familial relationship established between the families following diagnosis. A persistently elevated Hb A1c over a 1-year period prompted hemoglobinopathy screening in an adolescent male of New Zealand (NZ) European descent (case 1). Capillary electrophoresis (CE) revealed the variant was negatively charged and susceptible to oxidation, with multiple abnormal peaks detected (0.4-5.1% total Hb). Hb A1c analysis by cation exchange high performance liquid chromatography (HPLC) was the first indication of the variant in a pregnant female of NZ European descent (case 2). Cases 1 and 2 had normal complete blood counts. Isopropanol stability testing provided evidence the variant was unstable. We herein describe the characterization of Hb Kirikiriroa and clinical significance of the variant for interference with Hb A1c analysis by CE and cation exchange HPLC.


Asunto(s)
Hemoglobinas Anormales , Globinas alfa , 2-Propanol , Adolescente , Cromatografía Líquida de Alta Presión/métodos , Femenino , Hemoglobina Glucada/análisis , Hemoglobina Glucada/genética , Hemoglobinas Anormales/análisis , Hemoglobinas Anormales/genética , Humanos , Masculino , Mutación , Embarazo , Globinas alfa/análisis , Globinas alfa/genética
12.
Biomed Eng Lett ; 12(3): 263-283, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35892029

RESUMEN

In recent years, silicon photomultiplier (SiPM) is replacing the photomultiplier tube (PMT) in positron emission tomography (PET) systems due to its superior properties, such as fast single-photon timing response, small gap between adjacent photosensitive pixels in the array, and insensitivity to magnetic fields. One of the technical challenges when developing SiPM-based PET systems or other position-sensitive radiation detectors is the large number of output channels coming from the SiPM array. Therefore, various signal multiplexing methods have been proposed to reduce the number of output channels and the load on the subsequent data acquisition (DAQ) system. However, the large PN-junction capacitance and quenching resistance of the SiPM yield undesirable resistance-capacitance delay when multiple SiPMs are combined, which subsequently causes the accumulation of dark counts and signal fluctuation of SiPMs. Therefore, without proper SiPM signal handling and processing, the SiPMs may yield worse timing characteristics than the PMTs. This article reviews the evolution of signal readout and multiplexing methods for the SiPM. In this review, we focus primarily on analog electronics for SiPM signal multiplexing, which allows for the reduction of DAQ channels required for the SiPM-based position-sensitive detectors used in PET and other radiation detector systems. Although the applications of most technologies described in the article are not limited to PET systems, the review highlights efforts to improve the physical performance (e.g. spatial, energy, and timing resolutions) of PET detectors and systems.

13.
Clin Biochem ; 107: 62-66, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35580651

RESUMEN

OBJECTIVES: To describe a novel ß-globin variant that interferes with HbA1c analysis by cation exchange HPLC. DESIGN AND METHODS: Diabetes screening by HbA1c measurement was assessed using cation exchange HPLC and an immunoassay point-of-care analyzer. Routine hemoglobinopathy screening was performed including CBC, HbF and HbA2 measurement by cation exchange HPLC and capillary electrophoresis (CE). Further variant characterization was undertaken by ESI TOF mass spectrometry and DNA sequencing. RESULTS: Discordant HbA1c results were obtained for our subject, with elevated HbA1c of 52 mmol/mol measured by cation exchange HPLC and a normal level of 34 mmol/mol by immunoassay. Abnormal HbA1c peak shape prompted hemoglobinopathy screening to investigate potential variant interference. Cation exchange HPLC (using ß-thalassemia program) and CE results were apparently normal, with HbF and HbA2 detected within reference intervals. ESI TOF mass spectrometry revealed the presence of a variant ß-globin chain. A novel missense variant was confirmed at codon 121 of the ß-globin gene [ß121 (GH4) Glu>Asp; HBB: c.366A>C], which we have named Hb Westport. CONCLUSIONS: Hb Westport is a novel ß-globin variant that interferes with HbA1c measurement by Bio-Rad D-100 cation exchange HPLC, giving a falsely elevated result. This was clinically significant for our subject because the erroneously elevated HbA1c value was above the diabetes diagnostic threshold. Alternative methods for diabetes assessment should be considered in subjects with Hb Westport.


Asunto(s)
Diabetes Mellitus , Hemoglobinopatías , Hemoglobinas Anormales , Talasemia beta , Cromatografía Líquida de Alta Presión/métodos , Hemoglobina Glucada/análisis , Hemoglobinopatías/genética , Hemoglobinas Anormales/genética , Humanos , Globinas beta/análisis , Globinas beta/genética , Talasemia beta/diagnóstico , Talasemia beta/genética
14.
Micromachines (Basel) ; 13(5)2022 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-35630262

RESUMEN

In the last decade, the vision systems have improved their capabilities to capture 3D images in bad weather scenarios. Currently, there exist several techniques for image acquisition in foggy or rainy scenarios that use infrared (IR) sensors. Due to the reduced light scattering at the IR spectra it is possible to discriminate the objects in a scene compared with the images obtained in the visible spectrum. Therefore, in this work, we proposed 3D image generation in foggy conditions using the single-pixel imaging (SPI) active illumination approach in combination with the Time-of-Flight technique (ToF) at 1550 nm wavelength. For the generation of 3D images, we make use of space-filling projection with compressed sensing (CS-SRCNN) and depth information based on ToF. To evaluate the performance, the vision system included a designed test chamber to simulate different fog and background illumination environments and calculate the parameters related to image quality.

15.
Sensors (Basel) ; 22(6)2022 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-35336314

RESUMEN

A short-range, compact, real-time pulsed laser rangefinder is constructed based on pulsed time-of-flight (ToF) method. In order to reduce timing discrimination error and achieve high ranging accuracy, gray-value distance correction and temperature correction are proposed, and are realized with a field programmable gate array (FPGA) in a real-time application. The ranging performances-such as the maximum ranging distance, the range standard deviation, and the ranging accuracy-are theoretically calculated and experimentally studied. By means of these proposed correction methods, the verification experimental results show that the achievable effective ranging distance can be up to 8.08 m with a ranging accuracy of less than ±11 mm. The improved performance shows that the designed laser rangefinder can satisfy on-line ranging applications with high precision, fast ranging speed, small size, and low implementation cost, and thus has potential in the areas of robotics, manufacturing, and autonomous navigation.

16.
Sensors (Basel) ; 22(6)2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35336474

RESUMEN

This study aimed to develop a magnetic resonance imaging (MRI)-compatible flow delivery system and individualized models of circle of Willis (CoW), which include 50% and 100% blockage in internal carotid artery (ICA50 and ICA100), and 100% blockage in vertebral artery (VA100). Images were obtained using 3D time-of-flight and phase-contrast magnetic resonance angiography (MRA) sequences, and changes in velocity and flow direction at CoW models were analyzed. For the ICA50 and VA100 models, the flow was similar to that of the normal model. For the ICA 50 model, it was found that 50% blockage did not affect cerebral blood flow. For the VA100 model, decreased flow in the posterior cerebral artery and a change to the flow direction in the posterior communicating artery were found. For the ICA100 model, particularly, decreased flow in the ipsilateral middle and anterior cerebral arteries and a change to the flow direction in the ipsilateral anterior cerebral artery of the CoW were found. These results demonstrated that the flow system with various CoW disease models tailored to individual characteristics could be used to predict stroke onset more quickly. For the ICA50 and VA100 models, the possibility of cerebral infarction was significantly lower. On the other hand, for the ICA100 model, there was a high possibility of decreased flow, which could lead to cerebral infarction.


Asunto(s)
Estenosis Carotídea , Arteria Carótida Interna/diagnóstico por imagen , Circulación Cerebrovascular , Círculo Arterial Cerebral/diagnóstico por imagen , Círculo Arterial Cerebral/patología , Humanos , Imagen por Resonancia Magnética
17.
Eur J Mass Spectrom (Chichester) ; 27(5): 191-204, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34738841

RESUMEN

Butyl-terminated poly(2-vinylpyridine) (P2VP), C4H9(C7H7N)nH, is evaluated for use as an external and internal mass calibrant in positive-ion matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). P2VP oligomers covering the m/z 450-4500 range are employed to calibrate a time-of-flight (TOF) mass spectrometer in linear and reflector mode, an ion mobility-quadrupole-time-of-flight (IM-Q-TOF) mass spectrometer, and a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. The proton affinity of P2VPs introduced by the numerous pyridyl groups leads to the almost exclusive formation of [M + H]+ ions with common acidic matrices like α-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) as well as with the non-acidic and aprotic matrices 1,8-dihydroxy-10H-anthracen-9-on (dithranol) and 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malonitrile (DCTB). This prevalence of [M + H]+ ions evenly spaced at Δ(m/z) = 105.0578 renders butyl-terminated P2VP oligomers as convenient mass calibrants. The mass accuracies achieved across various m/z ranges with different mass analyzers and modes of operation are evaluated by using established standard compounds. Results as obtained by internal or external calibration are presented. Further, the compilation of mass reference lists tailored to suit the respective analyzer modes is discussed and those reference files are provided.

18.
IEEE Trans Radiat Plasma Med Sci ; 5(5): 694-702, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34746539

RESUMEN

Development of a PET system capable of in-situ imaging requires a design that can accommodate the proton treatment beam nozzle. Among the several PET instrumentation approaches developed thus far, the dual-panel PET scanner is often used as it is simpler to develop and integrate within the proton therapy gantry. Partial-angle coverage of these systems can however lead to limited-angle artefacts in the reconstructed PET image. We have previously demonstrated via simulations that time-of-flight (TOF) reconstruction reduces the artifacts accompanying limited-angle data, and permits proton range measurement with 1-2 mm accuracy and precision. In this work we show measured results from a small proof-of-concept dual-panel PET system that uses TOF information to reconstruct PET data acquired after proton irradiation. The PET scanner comprises of two detector modules, each comprised of an array of 4×4×30 mm3 lanthanum bromide scintillator. Measurements are performed with an oxygen-rich gel-water, an adipose tissue equivalent material, and in vitro tissue phantoms. For each phantom measurement, 2 Gy dose was deposited using 54 - 100 MeV proton beams. For each phantom, a Monte Carlo simulation generating the expected distribution of PET isotope from the corresponding proton irradiation was also performed. Proton range was calculated by drawing multiple depth-profiles over a central region encompassing the proton dose deposition. For each profile, proton range was calculated using two techniques (a) 50% pick-off from the distal edge of the profile, and (b) comparing the measured and Monte Carlo profile to minimize the absolute sum of differences over the entire profile. A 10 min PET acquisition acquired with minimal delay post proton-irradiation is compared with a 10 min PET scan acquired after a 20 min delay. Measurements show that PET acquisition with minimal delay is necessary to collect 15O signal, and maximize 11C signal collection with a short PET acquisition. In comparison with the 50% pick-off technique, the shift technique is more robust and offers better precision in measuring the proton range for the different phantoms. Range measurements from PET images acquired with minimal delay, and the shift technique demonstrate the ability to achieve <1.5 mm accuracy and precision in estimating proton range.

19.
Sensors (Basel) ; 21(19)2021 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-34640677

RESUMEN

To solve the problem of heavy workload and high cost when acquiring the position of Ultra-Wideband (UWB) mobile base stations in sports fields, a fast self-positioning algorithm for UWB mobile base stations algorithm based on Time of Flight (TOF) is proposed. First, according to the layout of the base stations in the sports field, the local coordinate system is determined, and an equation based on the ranging information between the base stations is established; the Least Square method is used to calculate the coordinates of each base station, and the Newton Iteration method is used to converge the positioning results. Then the origin and propagation law of positioning error, as well as the method of reducing the positioning error are analyzed. The simulation data and experimental results show that the average positioning accuracy of the mobile base station is within 0.05 m, which meets the expected accuracy of the base station position measurement. Compared with traditional manual measurement methods, base station self-positioning can effectively save deployment time and reduce workload.

20.
Sensors (Basel) ; 21(16)2021 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-34451008

RESUMEN

The purpose of this study was to investigate the feasibility of a time-of-flight (TOF) brain positron emission tomography (PET) providing high-quality images. It consisted of 30 detector blocks arranged in a ring with a diameter of 257 mm and an axial field of view of 52.2 mm. Each detector block was composed of two detector modules and two application-specific integrated circuit (ASIC) chips. The detector module was composed of an 8 × 8 array of 3 × 3 mm2 multi-pixel photon counters and an 8 × 8 array of 3.11 × 3.11 × 15 mm3 lutetium yttrium oxyorthosilicate scintillators. The 64-channel individual readout ASIC was used to acquire the position, energy, and time information of a detected gamma ray. A coincidence timing resolution of 187 ps full width at half maximum (FWHM) was achieved using a pair of channels of two detector modules. The energy resolution and spatial resolution were 6.6 ± 0.6% FWHM (without energy nonlinearity correction) and 2.5 mm FWHM, respectively. The results of this study demonstrate that the developed TOF brain PET could provide excellent performance, allowing for a reduction in radiation dose or scanning time for brain imaging due to improved sensitivity and signal-to-noise ratio.


Asunto(s)
Fotones , Tomografía de Emisión de Positrones , Encéfalo/diagnóstico por imagen , Electrónica , Estudios de Factibilidad