Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Acta Endocrinol (Buchar) ; 17(3): 393-398, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35342463

RESUMEN

A 62 years old woman was diagnosed with multinodular toxic goiter and primary hyperparathyroidism/left parathyroid adenoma by hormonal assessment, ultrasound and nuclear thyroid/parathyroid scans. Cervical ultrasound illustrated a multinodular aspect of the thyroid with solid nodules and cystic-component nodules; the larger one represented a multinodular complex with necrosis areas in the left thyroid lobe, ACR TI-RADS score 4 (moderately suspicious). Functional nuclear imaging was performed for accurate differential diagnosis between thyroid vs. parathyroid localization, between cold vs. hot nodules, and eventually, for guiding the choice of a subsequent Fine-Needle Aspiration Biopsy (FNAB). Scans described an early intense 99mTc-sestaMIBI uptake with no 99mTc-pertechnetate uptake in the left thyroid lobe larger nodule. Due to the suspicion of malignancy for this nodule, we performed an additional scan (1 hour before the classical 2 hours parathyroid delayed scan). The intense uptake persists in both delayed scans suggesting no malignant phenotype and which was confirmed after surgery by benign histology. In conclusion, using a 99mTc-sestaMIBI personalized protocol, related to the radiotracer cellular uptake mechanisms: 1 hour scan (supplementary image, corresponding to the maximum uptake pattern of 99mTc-sestaMIBI for cancer cells) and 2 hours scan (for parathyroid washout evaluation) may avoid unnecessary extensive thyroid surgery.

2.
Otolaryngol Head Neck Surg ; 160(3): 457-464, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30829140

RESUMEN

OBJECTIVES: As the country ages, thyroidectomies can be expected to be performed more frequently among the elderly. In this study, we stratified patients by age to explore demographics and complications of patients undergoing thyroidectomy. STUDY DESIGN: Retrospective study with a national database. SETTING: Nationwide Inpatient Sample. SUBJECTS AND METHODS: A total of 414,079 thyroidectomy cases from 2005 to 2013 were identified. Complications, outcomes, demographics, length of stay, and hospital charges were evaluated among patients and stratified by age into 4 cohorts: younger (<65 years), advanced age (65-74 years), elderly (75-84 years), and superelderly (≥85 years). RESULTS: Of 414,079 thyroidectomy cases identified, patients aged <65 years accounted for 75.6% of cases, while those aged 65-74, 75-84, and ≥85 years accounted for 16.3%, 7.2%, and 0.9%, respectively ( P < .001). There was a significant difference in length of stay, total hospital charges, and mortality throughout the different age groups ( P < .001), all trending upward with advancing age. In the aging population, incidence of recurrent laryngeal nerve injury, transfusion of erythrocytes, and acute cardiac complications increased with increasing age ( P < .001), while hypoparathyroidism decreased with age ≥65 but ≤85 years ( P < .001). Patients aged ≥75 years had increased odds of mortality as compared with their younger counterparts ( P < .001). CONCLUSION: This study utilized a national database to describe and elucidate trends in older populations undergoing thyroidectomy. Thyroid-related complications, including blood transfusion and recurrent laryngeal nerve injury, increased with increasing patient age. This information will help to guide pre- and postoperative care for aging patients undergoing thyroidectomy.


Asunto(s)
Complicaciones Posoperatorias/epidemiología , Enfermedades de la Tiroides/cirugía , Tiroidectomía/estadística & datos numéricos , Distribución por Edad , Factores de Edad , Anciano , Anciano de 80 o más Años , Bases de Datos Factuales , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Enfermedades de la Tiroides/epidemiología , Enfermedades de la Tiroides/patología , Tiroidectomía/efectos adversos , Estados Unidos/epidemiología
3.
J Ultrasound Med ; 37(11): 2631-2636, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30099745

RESUMEN

OBJECTIVES: Ultrasonography (US) has been considered to have a more limited role in the diagnosis of pyriform sinus fistulas than computed tomography. The aim of this study was to evaluate the US characteristics of pyriform sinus fistulas involving the thyroid gland in an attempt to improve our ability to diagnose this condition using US. METHODS: Between 2005 and 2016, 14 patients with pyriform sinus fistulas presenting as suppurative thyroiditis or as thyroid nodules were enrolled in the study. Their US images were reviewed to identify US characteristics indicating the presence of an underlying pyriform sinus fistula and compared with the computed tomographic images. RESULTS: A hypoechoic tubular lesion across the thyroid gland was identified in 9 patients (64.3%). Hyperechoic foci or echogenic lines were found within the lesion in 10 patients (71.4%). A hypoechoic rim was found at the boundary of the lesion in 7 patients (50.0%). A lesion emerging from the posterolateral aspect of the thyroid cartilage was found in 4 patients (28.6%). Thirteen (92.9%) of the 14 patients had 1 of these 4 findings. CONCLUSIONS: Ultrasonography would be a useful diagnostic modality for indicating the presence of an underlying pyriform sinus fistula in patients with suppurative thyroiditis or a thyroid nodule and can be used as a first-line diagnostic tool to screen for pyriform sinus fistulas.


Asunto(s)
Seno Piriforme/anomalías , Seno Piriforme/diagnóstico por imagen , Fístula del Sistema Respiratorio/diagnóstico por imagen , Enfermedades de la Tiroides/diagnóstico por imagen , Glándula Tiroides/diagnóstico por imagen , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Fístula , Humanos , Lactante , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Ultrasonografía , Adulto Joven
4.
J Ultrasound Med ; 37(11): 2527-2535, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29603330

RESUMEN

OBJECTIVES: This study investigated the potential of a clinical decision support approach for the classification of metastatic and tumor-free cervical lymph nodes (LNs) in papillary thyroid carcinoma on the basis of radiologic and textural analysis through ultrasound (US) imaging. METHODS: In this research, 170 metastatic and 170 tumor-free LNs were examined by the proposed clinical decision support method. To discover the difference between the groups, US imaging was used for the extraction of radiologic and textural features. The radiologic features in the B-mode scans included the echogenicity, margin, shape, and presence of microcalcification. To extract the textural features, a wavelet transform was applied. A support vector machine classifier was used to classify the LNs. RESULTS: In the training set data, a combination of radiologic and textural features represented the best performance with sensitivity, specificity, accuracy, and area under the curve (AUC) values of 97.14%, 98.57%, 97.86%, and 0.994, respectively, whereas the classification based on radiologic and textural features alone yielded lower performance, with AUCs of 0.964 and 0.922. On testing the data set, the proposed model could classify the tumor-free and metastatic LNs with an AUC of 0.952, which corresponded to sensitivity, specificity, and accuracy of 93.33%, 96.66%, and 95.00%. CONCLUSIONS: The clinical decision support method based on textural and radiologic features has the potential to characterize LNs via 2-dimensional US. Therefore, it can be used as a supplementary technique in daily clinical practice to improve radiologists' understanding of conventional US imaging for characterizing LNs.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Ganglios Linfáticos/diagnóstico por imagen , Metástasis Linfática/diagnóstico por imagen , Cáncer Papilar Tiroideo/patología , Neoplasias de la Tiroides/patología , Humanos , Cuello , Radiología , Estudios Retrospectivos , Sensibilidad y Especificidad , Ultrasonografía
5.
J Ultrasound Med ; 37(10): 2325-2331, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29498418

RESUMEN

OBJECTIVES: To assess the yield of neck ultrasound (US) when serum thyroglobulin (Tg) is undetectable (<0.1 ng/mL) compared to elevated serum Tg in patients with differentiated papillary thyroid carcinoma (PTC) treated with thyroidectomy and radioactive iodine 131 (RAI) ablation. METHODS: A retrospective chart review was conducted from 2010 through 2015 at an academic institution evaluating US results in patients with serum Tg levels obtained within 6 months of a neck US examination after thyroidectomy and RAI. The reference standard for recurrence was pathologic results from US-guided fine-needle aspiration (FNA) or follow-up for at least 1 year. RESULTS: Among 76 patients with undetectable serum Tg levels, there were 19 examinations in 18 patients in which US raised the possibility of recurrence. None of these 18 patients had recurrence by FNA (n = 8) or clinical follow-up of at least 1 year (n = 10). Among 65 patients with elevated serum Tg levels, there were 24 examinations in 22 patients in which US raised the possibility of recurrence. Twelve patients underwent FNA, with 9 patients (34.6%) showing PTC; 7 patients had follow-up neck US examinations showing stability of findings; and 3 patients were lost to follow up. The yield of neck US was significantly lower when serum Tg was undetectable compared to when levels were elevated (P = .001). CONCLUSIONS: Neck US did not identify recurrent PTC when the serum Tg level was undetectable in patients who underwent total thyroidectomy and RAI therapy. Eliminating neck US when serum TG levels are undetectable could decrease unnecessary imaging examinations without negatively affecting the ability to detect recurrent disease.


Asunto(s)
Recurrencia Local de Neoplasia/diagnóstico por imagen , Tiroglobulina/sangre , Cáncer Papilar Tiroideo/diagnóstico por imagen , Neoplasias de la Tiroides/diagnóstico por imagen , Ultrasonografía/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Radioisótopos de Yodo/uso terapéutico , Masculino , Persona de Mediana Edad , Cuello , Recurrencia Local de Neoplasia/sangre , Recurrencia Local de Neoplasia/terapia , Radioterapia Adyuvante , Estudios Retrospectivos , Cáncer Papilar Tiroideo/sangre , Cáncer Papilar Tiroideo/terapia , Glándula Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/sangre , Neoplasias de la Tiroides/terapia , Tiroidectomía , Adulto Joven
6.
J Ultrasound Med ; 37(10): 2311-2324, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29575028

RESUMEN

Ultrasound (US) plays a critical role in the evaluation, treatment, screening, and surveillance of thyroid malignancy in pediatric patients. This review aims to summarize recent advances in this topic. Improvements in imaging technology have amplified the advantage of US and US-guided fine-needle aspiration biopsy for thyroid nodule evaluation, cancer diagnosis, and surgical planning. Ultrasound has a definitive screening role for early cancer detection in high-risk patients, including those with a history of radiation exposure from childhood treatments, environmental radiation disasters, or hereditary/familial cancer syndromes. Finally, US is a key component of lifelong surveillance for recurrence among pediatric thyroid cancer survivors.


Asunto(s)
Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Ultrasonografía/métodos , Biopsia con Aguja Fina , Niño , Humanos , Biopsia Guiada por Imagen , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía Intervencional
7.
J Ultrasound Med ; 37(11): 2565-2574, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29575135

RESUMEN

OBJECTIVES: To compare the diagnostic efficacy, complication rate, and core needle biopsy (CNB) specimen yield in 18- versus 20-gauge ultrasound (US)-guided CNB for diagnosis of thyroid nodules. METHODS: We included 81 consecutive thyroid nodules with US-guided biopsy by a 20-gauge core needle and 86 consecutive thyroid nodules with US-guided biopsy by an 18-gauge core needle during 2 years. The rate of inconclusive results, including nondiagnostic or atypia/follicular lesion of undetermined significance, was compared. The diagnostic performance for malignancy was assessed in nodules with a final diagnosis. The complication rate and CNB specimen yield were also compared. RESULTS: Eighteen-gauge CNB showed a lower rate of nondiagnostic results (1.2% versus 8.6%; P = .024) than 20-gauge CNB; however, the rates of atypia/follicular lesion of undetermined significance and inconclusive results were not significantly different between the groups (P > .05). In addition, 18-gauge CNB showed higher sensitivity (75.0% versus 66.7%), a higher negative predictive value (83.9% versus 75.9%), and higher accuracy (78.3% versus 74.4%) for detecting malignancy than 20-gauge CNB, although the results did not achieve statistical significance. No major complications occurred in either of the CNB groups. The 18-gauge needle group had significantly fewer CNBs and larger specimen diameters (P < .001). CONCLUSIONS: Core needle biopsy with an 18-gauge needle could be more effective for the diagnosis of thyroid nodules than CNB with a 20-gauge needle.


Asunto(s)
Nódulo Tiroideo/patología , Ultrasonografía Intervencional/métodos , Biopsia con Aguja Gruesa , Femenino , Humanos , Biopsia Guiada por Imagen/métodos , Masculino , Persona de Mediana Edad , Agujas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Nódulo Tiroideo/diagnóstico por imagen
8.
J Ultrasound Med ; 37(7): 1777-1788, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29315789

RESUMEN

OBJECTIVES: To prospectively evaluate the diagnostic performance of 3-dimensional (3D) shear wave elastography (SWE) for assessing thyroid nodules. METHODS: A total of 176 surgically or cytologically confirmed thyroid nodules (63 malignant and 113 benign) in 176 patients who had undergone conventional ultrasound (US), 2-dimensional (2D) SWE, and 3D SWE examinations were included in this study. Quantitative elasticity values (mean elasticity, maximum elasticity, and standard deviation of elasticity of a large region of interest and mean elasticity of a 2-mm region of interest) were measured on 2D and 3D SWE. Diagnostic performances of conventional US, 2D SWE, and 3D SWE were assessed. The role of 2D and 3D SWE in reducing unnecessary fine-needle aspiration (FNA) for nodules with low suspicion was also evaluated. RESULTS: The diagnostic performances in terms of the area under the receiver operating characteristic curve were 0.612 for conventional US, 0.836 for 2D SWE (P < .001 in comparison with conventional US), and 0.839 for 3D SWE (P < .001 in comparison with conventional US). The mean elasticity achieved the highest diagnostic performance in 2D SWE, whereas the standard deviation of elasticity achieved the highest performance in 3D SWE, although no significant difference was found between them (P > .05). Three-dimensional SWE increased the specificity in comparison with 2D SWE (88.5% versus 82.3%; P = .039). For the 37 nodules with low suspicion on conventional US imaging, 2D SWE was able to avoid unnecessary FNA in 77.1% (27 of 35) of benign nodules, and 3D SWE further increased the number to 88.6% (31 of 35). CONCLUSIONS: Three-dimensional SWE is a useful tool for predicting thyroid nodule malignancy and reducing unnecessary FNA procedures in thyroid nodules with low suspicion of malignancy.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Imagenología Tridimensional/métodos , Nódulo Tiroideo/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Glándula Tiroides/diagnóstico por imagen , Adulto Joven
9.
J Ultrasound Med ; 37(7): 1713-1716, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29288581

RESUMEN

OBJECTIVES: To compare the adequacy of 23-, 25-, and 27-gauge needles in the fine-needle aspiration biopsy of thyroid nodules to develop guidelines for the collection of better specimens for cytologic diagnosis. METHODS: This randomized prospective study included 156 consecutively enrolled patients with 156 nodules. Each nodule was aspirated with a needle of each size. The obtained specimens were analyzed independently by 2 cytopathologists, and adequacy rates were calculated. RESULTS: In our investigation, there were no statistically significant differences among the adequacy rates achieved with 23-, 25-, and 27-gauge needles (88.5%, 90.4%, and 89.7%, respectively; P > .05). The adequacy rates achieved with all 3 needle sizes in hyperechoic nodules were higher than those in hypoechoic samples (P < .05). Finally, no differences in adequacy for the different needle sizes were observed according to nodule size (P > .05). CONCLUSIONS: We conclude that fine-needle aspiration biopsy with a 27-gauge needle can aspirate an adequate specimen for cytopathologic diagnosis of thyroid nodules. The likelihood that inadequate materials will be obtained from hypoechoic nodules is higher than that for hyperechoic nodules.


Asunto(s)
Nódulo Tiroideo/patología , Ultrasonografía Intervencional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Fina/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Agujas , Estudios Prospectivos , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Nódulo Tiroideo/diagnóstico por imagen , Adulto Joven
10.
J Ultrasound Med ; 37(6): 1423-1429, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29219197

RESUMEN

OBJECTIVES: We compared the efficacy, safety, and cost-effectiveness of ultrasound-guided percutaneous polidocanol injection and percutaneous ethanol injection for the treatment of benign cystic and predominantly cystic thyroid nodules. METHODS: A total of 135 cystic thyroid nodules treated by percutaneous ethanol injection and 136 cystic thyroid nodules treated by percutaneous polidocanol injection were enrolled retrospectively in this study from May 2010 to March 2016. The nodules were followed after 1, 3, 6, and 12 months. Nodule volumes, symptoms scores, and cosmetic scores were assessed before treatment and at follow-up. The therapeutic success rate, safety, and cost-effectiveness between the groups were also compared. RESULTS: No significant differences in the reduction of the nodule volume, volume reduction rate, and therapeutic success were observed between the groups with cystic and predominantly cystic thyroid nodules during follow-up (P > .05). Neither the cosmetic scores (P = .59; P = .42) nor the symptom scores (P = .32; P = .73) in the cystic and predominantly cystic nodules were significantly different between the groups at the last follow-up. The complication rates for ethanol were higher than those for polidocanol (P < .05). However, the cost of polidocanol injection was higher than that of ethanol injection for cystic thyroid nodules (mean ± SD, US$97.18 ± US$22.17 versus US$43.36 ± US$5.51; P < .01). CONCLUSIONS: Ultrasound-guided percutaneous polidocanol injection can be an alternative for sclerotherapy of cystic or predominantly cystic thyroid nodules. However, its cost was higher than that of percutaneous ethanol injection.


Asunto(s)
Etanol/uso terapéutico , Polietilenglicoles/uso terapéutico , Soluciones Esclerosantes/uso terapéutico , Escleroterapia/métodos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/terapia , Ultrasonografía Intervencional/métodos , Adolescente , Adulto , Anciano , Análisis Costo-Beneficio , Etanol/administración & dosificación , Etanol/economía , Femenino , Estudios de Seguimiento , Humanos , Inyecciones Intralesiones , Masculino , Persona de Mediana Edad , Polidocanol , Polietilenglicoles/administración & dosificación , Polietilenglicoles/economía , Estudios Retrospectivos , Soluciones Esclerosantes/administración & dosificación , Soluciones Esclerosantes/economía , Escleroterapia/economía , Glándula Tiroides/diagnóstico por imagen , Resultado del Tratamiento , Adulto Joven
11.
J Ultrasound Med ; 37(5): 1143-1149, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29064111

RESUMEN

OBJECTIVES: To evaluate the parenchymal elasticity of the thyroid gland with acoustic radiation force impulse imaging in pediatric patients with Hashimoto thyroiditis and to compare it with healthy volunteers. METHODS: Twenty-six patients with Hashimoto thyroiditis and 26 healthy volunteers between 6 and 17 years were included. The shear wave velocity (SWV) values of both thyroid lobes in both groups were evaluated. RESULTS: The age and sex characteristics of the controls and patients with Hashimoto thyroiditis were similar. The SWV of the thyroid gland in patients with Hashimoto thyroiditis (mean ± SD, 1.67 ± 0.63 m/s) was significantly higher than that in the control group (1.30 ± 0.13 m/s; P < .001). There was no significant difference between the thyroid lobes in both groups. A receiver operating characteristic curve analyses showed an optimal cutoff value of 1.41 m/s, with 73.1% sensitivity, 80.8% specificity, a 79.2 % positive predictive value, and a 75.0% negative predictive value (area under the curve, 0.806; P < .001). In patients with Hashimoto thyroiditis, there was a positive correlation between the SWV values versus anti-thyroperoxidase (Pearson r = 0.46; P = .038). There were no correlations between age, body mass index, thyroid function test results, and anti-thyroglobulin values and versus SWV values. Also, no significant differences were seen between the groups for gland size, gland vascularity, and l-thyroxine treatment. CONCLUSIONS: Acoustic radiation force impulse elastography showed a significant difference in the stiffness of the thyroid gland between children with Hashimoto thyroiditis and the healthy group. Using acoustic radiation force impulse elastography immediately after a standard ultrasound evaluation may predict chronic autoimmune thyroiditis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Enfermedad de Hashimoto/diagnóstico por imagen , Enfermedad de Hashimoto/fisiopatología , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/fisiopatología , Adolescente , Niño , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados
12.
J Ultrasound Med ; 37(3): 725-736, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28960465

RESUMEN

OBJECTIVES: To evaluate the diagnostic performance of Virtual Touch tissue imaging quantification (VTIQ; Siemens Medical Solutions, Mountain View, CA) in combination with the Thyroid Imaging Reporting and Data System (TI-RADS) for assessing thyroid nodules referred for biopsy. METHODS: A total of 197 surgically or cytologically proven thyroid nodules in 187 patients were included. Nodules evaluated by conventional ultrasound (US) and VTIQ examinations were classified into US TI-RADS categories. The shear wave velocity (SWV) on VTIQ was assessed, and the cutoff value was obtained from a receiver operating characteristic curve analysis. Diagnostic performances of conventional US, VTIQ, and their combination were compared. RESULTS: There were 134 benign and 63 malignant nodules. The sensitivity and specificity for the US TI-RADS were 98.4% and 20.1%, respectively. The areas under the receiver operating characteristic curves for the mean, maximum, minimum, and ratio of the SWV were 0.818, 0.805, 0.799, and 0.728. With a cutoff value of 2.90 m/s, the sensitivity and specificity of the mean SWV were 71.4% and 82.8%. By applying this value or less as a standard for downgrading TI-RADS category 4a to category 3 lesions, the specificity significantly rose from 20.1% to 47.0% (P < .001) without a loss of sensitivity. CONCLUSIONS: The additional application of VTIQ can improve the specificity of the TI-RADS for evaluating thyroid nodules without a loss of sensitivity.


Asunto(s)
Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía/métodos , Adolescente , Adulto , Anciano , Biopsia , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistemas de Información Radiológica , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Interfaz Usuario-Computador , Adulto Joven
13.
J Ultrasound Med ; 37(1): 173-178, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28736947

RESUMEN

OBJECTIVES: The purpose of this study was to assess the intraobserver and interobserver variability in ultrasound (US) measurements of thyroid nodules. METHODS: We performed a prospective study of the US examinations of 73 patients with 122 thyroid nodules greater than 5 mm in size. Ultrasound measurements in 4 dimensions (anteroposterior, transverse, longitudinal, and maximum diameters) and measurement of the estimated volume (using the ellipsoid formula) of each thyroid nodule were performed twice by 2 independent radiologists (A and B, with 10 years and 6 months of experience, respectively). The intraobserver and interobserver variability in measurements of thyroid nodules was assessed by a Bland-Altman analysis of agreement. The absolute values for intraobserver and interobserver variability were compared by a paired t test. RESULTS: The 95% intraobserver and interobserver limits of agreement for the anteroposterior, transverse, longitudinal, and maximum diameters and estimated volume of thyroid nodules were ±18.2%, ± 14.3%, and ±21.0%; ± 17.2%%, ± 17.3%, and 18.2%; ± 14.6%, ± 15.5%, and ±22.3%; ± 13.8%, ± 15.5%, and ±19.6%; and ±30.2%, ± 27.7%, and ±44.1%, respectively. The absolute values for intraobserver variability were lower than those for interobserver variability for all measurements. CONCLUSIONS: There was considerable intraobserver and interobserver variability in US measurement of thyroid nodules, which must be taken into account during follow-up US examinations of patients with thyroid nodules.


Asunto(s)
Variaciones Dependientes del Observador , Nódulo Tiroideo/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Glándula Tiroides/diagnóstico por imagen
14.
J Ultrasound Med ; 37(3): 783-791, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28850707

RESUMEN

Ectopic intrathyroidal thymic tissue is a benign lesion of nonthyroid origin occasionally found in the pediatric thyroid gland. Accurate diagnosis of such lesions is critical to avoid unnecessary biopsy or surgery. Twelve children referred to our center for the concern of thyroid nodules were found to have intrathyroidal thymic tissue. Most of the lesions had a classic sonographic appearance of a hypoechoic mass with sharp margins and multiple focal internal nonshadowing echogenicities identical to thymic tissue. Sonography and, in select cases, fine-needle aspiration can be used to diagnose benign thymic tissue within the thyroid and avoid unnecessary surgery.


Asunto(s)
Glándula Tiroides/anomalías , Glándula Tiroides/diagnóstico por imagen , Nódulo Tiroideo , Ultrasonografía/métodos , Adolescente , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Lactante , Masculino , Estudios Retrospectivos
15.
J Ultrasound Med ; 37(3): 601-609, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28906009

RESUMEN

OBJECTIVES: We aimed to investigate the diagnostic performance of shear wave elastography (SWE) combined with conventional ultrasonography (US) for differentiating between benign and malignant thyroid nodules of different sizes. METHODS: A total of 445 thyroid nodules from 445 patients were divided into 3 groups based on diameter (group 1, ≤ 10 mm; group 2, 10-20 mm; and group 3, > 20 mm). The mean elasticity index of the whole lesion was automatically calculated, and the threshold for differentiation between benign and malignant nodules was constructed by a receiver operating characteristic curve analysis. Diagnostic performances of conventional US and SWE were compared by using pathologic results as reference standards. RESULTS: The mean elasticity was significantly higher in malignant versus benign nodules for all size groups. The differences in mean elasticity in the size groups were not statistically significant for malignant or benign nodules. The specificity of US combined with SWE for group 1 was significantly higher than that for groups 2 and 3 (77.8% versus 62.9% and 53.3%; P < .05), and compared with group 1, the sensitivity was significantly higher for groups 2 and 3 (92.4% and 94.3% versus 80.7%; P < .05). When SWE was added, the specificity increased and the sensitivity and diagnostic accuracy decreased for group 1, and the sensitivity increased and the specificity decreased for groups 2 and 3; however, the differences were not significant. CONCLUSIONS: Combined with SWE, US yielded higher specificity for nodules of 10 mm and smaller and higher sensitivity for nodules larger than 10 mm.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Carga Tumoral , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Adulto Joven
16.
J Ultrasound Med ; 37(6): 1367-1377, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29120064

RESUMEN

OBJECTIVES: Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. METHODS: A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. RESULTS: The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. CONCLUSIONS: Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results.


Asunto(s)
Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía Intervencional/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Fina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Glándula Tiroides/cirugía , Nódulo Tiroideo/cirugía , Adulto Joven
17.
J Ultrasound Med ; 37(4): 1007-1014, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29044641

RESUMEN

OBJECTIVES: To evaluate qualitative and semiquantitative elastography for the diagnosis of intermediate suspicious thyroid nodules based on the 2015 American Thyroid Association (ATA) guidelines. METHODS: Through a retrospective search of our institutional database, 746 solid thyroid nodules found on grayscale ultrasonography, strain elastography, and ultrasound-guided fine-needle aspiration between June and November 2009 were collected. Among them, 80 nodules from 80 patients with an intermediate suspicion of malignancy based on the 2015 ATA guidelines that were 10 mm or larger were recruited as the final study nodules. Elastographic findings were categorized according to the criteria of Rago et al (J Clin Endocrinol Metab 2007; 92:2917-2922) and Asteria et al (Thyroid 2008; 18:523-531), and strain ratio values were calculated and recorded. The independent 2-sample t test and χ2 test (or Fisher exact test) were used to evaluate differences in clinical parameters between benign and malignant thyroid nodules. All variables were compared by univariate and multivariate logistic regression analyses, and odds ratios with 95% confidence intervals were calculated. RESULTS: Of the 80 nodules, 6 (7.5%) were malignant, and 74 (92.5%) were benign. No significant differences were observed in age, sex, nodule size, elasticity score, and strain ratio between benign and malignant nodules. No variables significantly predicted thyroid malignancy on the univariate analysis. On the multivariate logistic regression analysis, there were no independent variables associated with thyroid malignancy, including the elasticity score and strain ratio (all P > .05). CONCLUSIONS: Elastographic analysis using the elasticity score and strain ratio has limited ability to characterize the benignity or malignancy of thyroid nodules with an intermediate suspicion of malignancy based on the 2015 ATA guidelines.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Guías de Práctica Clínica como Asunto , Neoplasias de la Tiroides/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Adulto , Anciano , Bases de Datos Factuales , Diagnóstico Diferencial , Estudios de Evaluación como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sociedades Médicas , Glándula Tiroides/diagnóstico por imagen , Adulto Joven
18.
J Ultrasound Med ; 37(3): 667-674, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28880405

RESUMEN

OBJECTIVES: It is difficult to establish a diagnosis of the follicular variant of papillary thyroid carcinoma (PTC) using fine-needle aspiration cytology (FNAC). Preoperative features on ultrasound (US) imaging are different between follicular PTC and classic PTC. This study developed a risk score system to differentiate follicular PTC from classic PTC and to correlate the risk score of follicular PTC with its FNAC categories and pathologic features. METHODS: The US features, FNAC results, and pathologic reports of 156 follicular PTC nodules and 152 classic PTC nodules from 296 patients with PTC along with their clinical characteristics were reviewed retrospectively. A risk score system based on US features was developed by multivariate logistic regression to differentiate classic PTC from follicular PTC nodules. The risk scores were then correlated with the FNAC category and pathologic features of the nodules. RESULTS: The US risk score (5 × echogenicity + 3 × calcifications + 3 × marginal regularity) had an area under the receiver operating characteristic curve of 0.85 and a cutoff value of 8.0, with specificity of 87% and sensitivity of 69% for predicting a classic PTC nodule. The follicular PTC nodules with low Bethesda categorization (I-III) had a median US risk score of 6 (range, 0-11), which was higher than that of nodules with high categorization (IV-VI; median, 3; range, 0-11). CONCLUSIONS: The US risk score may be useful in differentiating classic PTC from follicular PTC and complementary to FNAC in identifying follicular PTC.


Asunto(s)
Adenocarcinoma Folicular/diagnóstico por imagen , Carcinoma Papilar/diagnóstico por imagen , Neoplasias de la Tiroides/diagnóstico por imagen , Ultrasonografía/métodos , Adenocarcinoma Folicular/patología , Biopsia con Aguja Fina , Carcinoma Papilar/patología , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Cáncer Papilar Tiroideo , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Neoplasias de la Tiroides/patología
19.
J Ultrasound Med ; 37(2): 425-437, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28880412

RESUMEN

OBJECTIVES: We aimed to determine the most efficient quantitative parameters to establish a contrast-enhanced ultrasound (US) assessment system for distinguishing between benign and malignant thyroid nodules. METHODS: A total of 167 patients with thyroid solitary nodules had the diagnosis confirmed by surgery or fine-needle aspiration. Quantitative contrast-enhanced US indicators (time to peak, time from peak to one-half, ascend slope, descend slope, peak intensity, and area under the curve [AUC]) were gathered in nodule and perinodule areas. Univariate and multivariate logistic regression analyses were performed. Receiver operating characteristic curves were generated. Sensitivities, specificities, and positive and negative predictive values were calculated to identify the best cutoff value. RESULTS: The univariate logistic regression model showed that the peak intensity, ascend slope, descend slope, and AUC were significant indicators for discriminating benign from malignant nodules under contrast-enhanced US (P < .0001). For thyroid nodules, low peak intensity, ascend slope, and AUC and high descend slope values were significant indicators of malignancy. However, in perinodule areas, high peak intensity, ascend slope, and AUC and low descend slope values were significantly associated with malignancies. The cutoff values for the nodule peak intensity, ascend slope, descend slope, and AUC were 20.75, 0.91, -0.2, and 1818.23, respectively. The cutoff values for the ratios of the nodule versus perinodule peak intensity, ascend slope, descend slope, and AUC were 0.90, 0.95, 0.96, and 0.96. The nodule-to-perinodule peak intensity ratio showed the best diagnostic efficiency, with 80.41% sensitivity and 80.00% specificity. CONCLUSIONS: Quantitative contrast-enhanced US indicators help discriminate benign from malignant thyroid nodules. The nodule-to-perinodule peak intensity ratio showed the best diagnostic efficiency.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Neoplasias de la Tiroides/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Diagnóstico Diferencial , Estudios de Evaluación como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Glándula Tiroides/diagnóstico por imagen
20.
Int J Surg ; 11 Suppl 1: S40-1, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24380549

RESUMEN

BACKGROUND: This is a preliminary analysis of intraoperative neuromonitoring (IONM)-related websites available to the general public with respect to thyroid surgery. METHODS: Four key terms and/or phrases (neuromonitoring AND thyroid AND neck surgery, intraoperative neuromonitoring, intraoperative electrophysiological monitoring, IONM) were entered separately into the search engines Google.com, Yahoo.com and Bing.com. The first 50 results obtained for each search procedure were evaluated. Websites were evaluated for content quality using the validated DISCERN rating instrument. Readability was graded by the Flesch Reading Ease Score and the Flesch-Kincaid Grade Level. RESULTS: The results were related to scientific publications in most cases (64%). A large percentage (59%) of the servers are located in the USA. The main language used is English (91%); only 19% of the websites are multilingual or in other languages. 58% of the sites were rated as excellent to good and 42% as fair to poor. The median Flesch Reading Ease Score was 49.6; the median Flesch-Kincaid Grade Level was 13.85. CONCLUSIONS: World Wide Web information about IONM in thyroid surgery is too specific and difficult and poorly accessible to the general public.


Asunto(s)
Información de Salud al Consumidor , Internet , Monitorización Neurofisiológica Intraoperatoria/métodos , Glándula Tiroides/cirugía , Humanos , Motor de Búsqueda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA