Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(2)2022 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-35062551

RESUMEN

Sensor measurements of civil structures provide basic information on their performance. However, it is impossible to install sensors at every location owing to the limited number of sensors available. Therefore, in this study, we propose an optimal sensor placement (OSP) algorithm while reducing the system order by using the constraint condition between the master and slave modes from the target modes. The existing OSP methods are modified in this study, and an OSP approach using a constrained dynamic equation is presented. The validity and comparison of the proposed methods are illustrated by utilizing a numerical example that predicts the OSPs of the truss structure. It is observed that the proposed methods lead to different sensor layouts depending on the algorithm criteria. Thus, it can be concluded that the OSP algorithm meets the measurement requirements for various methods, such as structural damage detection, system identification, and vibration control.

2.
AJR Am J Roentgenol ; 204(2): W184-91, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25615779

RESUMEN

OBJECTIVE. The purpose of this study was to evaluate the radiation dose and image quality of target mode prospectively ECG-gated volumetric CT angiography (CTA) performed with a 320-MDCT scanner compared with the radiation dose and image quality of ungated helical CTA performed with a 64-MDCT scanner. MATERIALS AND METHODS. An experience with CTA for cardiovascular indications in neonates and infants 0-6 months old was retrospectively assessed. Radiation doses and quantitative and qualitative image quality scores of 28 CTA examinations performed with a 320-MDCT scanner and volumetric target mode prospective ECG gating plus iterative reconstruction (target mode) were compared with the doses and scores of 28 CTA examinations performed with a 64-MDCT scanner and ungated helical scanning plus filtered back projection reconstruction (ungated mode). All target mode studies were performed during free breathing. Seven ungated CTA examinations (25%) were performed with general endotracheal anesthesia. The findings of 17 preoperative CTA examinations performed in target mode were also compared with surgical reports for evaluation of diagnostic accuracy. RESULTS. All studies performed with target mode technique were diagnostic for the main clinical indication. Effective doses were significantly lower in the target mode group (0.51 ± 0.19 mSv) compared with the ungated mode group (4.8 ± 1.4 mSv) (p < 0.0001). Quantitative analysis revealed no statistically significant difference between the two groups with respect to signal-to-noise ratio (of pulmonary artery and aorta) and contrast-to-noise ratio. Subjective image quality was significantly better with target mode than with ungated mode (p < 0.0001). CONCLUSION. Target mode prospectively ECG-gated volumetric scanning with iterative reconstruction performed with a 320-MDCT scanner has several benefits in cardiovascular imaging of neonates and infants, including low radiation dose, improved image quality, high diagnostic accuracy, and ability to perform free-breathing studies.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Angiografía Coronaria/métodos , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Tomografía Computarizada Espiral , Técnicas de Imagen Sincronizada Cardíacas/métodos , Electrocardiografía , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA