Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 290
Filtrar
1.
Bull Emerg Trauma ; 12(2): 58-66, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39224468

RESUMEN

Objective: Laryngeal mask airway (LMA) insertion has been found to reduce cardiovascular responses when compared to laryngoscopy and intubation. This research aimed to examine the impact of various techniques employed for LMA insertion on cardiovascular response. Methods: This randomized, double-blind clinical trial included 90 elective surgery candidates divided into three groups of 30. All patients underwent similar anesthesia. The LMA was inserted using the classical technique, 180° rotation technique, and face-to-face triple maneuver technique (FFTMT). The cardiovascular responses, the success rate of LMA placement, and other outcomes were documented and compared among the three methods. Results: The study revealed that the blood pressure of patients 10 minutes after LMA insertion using the rotational technique was higher than the standard technique (p=0.019). The pulse rate in the third (p=0.044, p=0.024) and fifth minutes (p=0.028, p=0.048) following the insertion of LMA demonstrated higher values when utilizing the FFTMT than the standard and rotational technique groups, respectively. Moreover, the incidence of sore throat following surgery in the FTFTM group was slightly greater than that observed with the standard and rotation techniques (p=0.389 and p=0.688, respectively). Conclusion: The findings of the present investigation indicated that implementing the classic technique for LMA placement resulted in a more consistent blood pressure (BP) and pulse rate (PR) response than the 180° rotation and FFTMT. Furthermore, the classical method exhibited a marginally lower success rate in terms of LMA insertion than the alternative methods.

2.
J Clin Med ; 13(17)2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39274512

RESUMEN

Background/Objectives: Neuromuscular blocking agents (NMBAs) are not usually necessary during the induction of general anesthesia in patients using supraglottic airway (SGA) devices. In this study, we assessed the incidences of rocuronium use in adult patients undergoing general anesthesia using SGA devices. Methods: From September 2022 to August 2023, the medical records of adult patients (≥19 years) who underwent orthopedic surgery using SGA devices were retrospectively investigated. The incidences of rocuronium use during anesthetic induction were analyzed according to the anesthetic induction drug. The association of rocuronium use during anesthesia was analyzed in terms of demographic (age, sex, height, and weight), surgical (surgical time), and anesthetic factors (premedication, anesthetic agent, anesthetic time). Results: In total, 321 patients were enrolled. The incidence rate of rocuronium use during anesthetic induction was 28.3%. In the subgroup analysis, patients receiving total intravenous anesthesia (TIVA) with propofol (PPF) and remifentanil showed a markedly lower incidence (14.4%) than the other anesthetic groups. Premedication or short anesthetic duration was associated with lower incidences of rocuronium use. Demographic and other anesthetic factors did not seem to affect the incidences of rocuronium use during anesthesia. Conclusions: The incidence of rocuronium use during anesthetic induction with SGA devices was significantly lower with the PPF-TIVA compared to that using remimazolam-TIVA or inhalational anesthesia. Premedication with midazolam and shorter operation times were associated with a significantly lower incidence of rocuronium use.

3.
Anaesthesiol Intensive Ther ; 56(2): 108-120, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39166502

RESUMEN

INTRODUCTION: The Air-Q Self Pressurized Airway Device with Blocker (SP Blocker) was compared to the Proseal Laryngeal Mask Airway (PLMA) during positive pressure ventilation regarding the primary outcome (oropharyngeal leak pressure [OLP]), secondary outcomes (peak inspiratory pressure [PIP], inspired tidal volume [ITV], expired tidal volume [ETV], leak volume [LV] and leak fraction [LF]), insertion time, ventilation score, fiber-optic glottis view score, and postoperative laryngopharyngeal parameters (LPM). MATERIAL AND METHODS: Adult healthy female patients scheduled for elective gynecological laparotomies under general anesthesia using controlled mechanical ventilation were recruited to a prospective randomized comparative clinical trial. Exclusion criteria were body mass index (BMI) ≥ 35 kg m -2 , El-Ganzouri score ≥ 5, upper airway problems, hiatus hernia or pregnancy. Patients were classified into an SP Blocker group ( n = 75) and a PLMA group ( n = 75). Primary and secondary outcomes were assessed initially and at fixed time points after successful insertion of devices. RESULTS: Initially after successful device insertion: the SP Blocker group showed statistically significant higher mean OLP (cmH 2 O) (29.46 ± 2.11 vs. 28.06 ± 1.83 respectively; 95% CI: -2.037 to -0.76, P < 0.0001), lower mean PIP (cmH 2 O) (15.49 ± 0.61 vs. 17.78 ± 1.04 respectively; 95% CI: 2.02 to 2.56, P < 0.0001), higher mean ITV (mL) (411 ± 30 vs. 403 ± 15 respectively; 95% CI: -15.65 to -0.347, P = 0.041), higher mean ETV (mL) (389 ± 12 vs. 354 ± 11 respectively; 95% CI: -38.72 to -31.29, P < 0.0001), lower mean LV (mL) (22 ± 18 vs. 49 ± 10 respectively; 95% CI: 22.3 to 31.7, P < 0.0001) and lower mean LF (%) (5 ± 2.04 vs. 12 ± 6.8 respectively; 95% CI: 5.38 to 8.62, P < 0.0001) than the PLMA group. Mean insertion time (seconds) was shorter in the SP Blocker group than the PLMA group (16.39 ± 2.81 vs. 18.63 ± 3.44 respectively; 95% CI: 1.23 to 3.25, P < 0.0001). The SP Blocker group offered a better fiber-optic glottis view score than the PLMA group without differences concerning ventilation score and LPM. CONCLUSIONS: SP Blocker provided as safe anesthesia during controlled mechanical ventilation as PLMA.


Asunto(s)
Anestesia General , Procedimientos Quirúrgicos Ginecológicos , Máscaras Laríngeas , Humanos , Femenino , Adulto , Procedimientos Quirúrgicos Ginecológicos/métodos , Estudios Prospectivos , Anestesia General/métodos , Persona de Mediana Edad , Procedimientos Quirúrgicos Electivos , Respiración con Presión Positiva/métodos , Parálisis/etiología
4.
Anaesthesia ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39110995

RESUMEN

BACKGROUND: The i-gel® Plus is a modified version of the i-gel® supraglottic airway device. It contains a wider drainage port; a longer tip; ramps inside the breathing channel; and an additional port for oxygen delivery. There has been no prospective evaluation of this device in clinical practice. METHODS: This international, multicentre, prospective cohort study aimed to evaluate the performance of the i-gel Plus in adult patients undergoing elective procedures under general anaesthesia. The primary outcome was overall insertion success rate, defined as the ability to provide effective airway management through the device from insertion until the end of the surgical procedure. Secondary outcomes included device performance and incidence of postoperative adverse events. Data from the first 1000 patients are reported. RESULTS: In total, 1012 patients were enrolled; 12 forms were excluded from the final analysis due to incomplete data leaving 1000 included patients (545 female). Overall insertion success rate was 98.6%, with a first-attempt success rate of insertion of 88.2%. A significant difference between females and males was seen for the overall success rate (97.4% vs. 99.6% respectively) but not for first-attempt successful insertion. Mean (SD) oropharyngeal seal pressure was 32 (7) cmH2O. The only independent factor that increased the risk of first-attempt failure was low operator experience. Complications included desaturation < 85% in 0.6%; traces of blood on the device in 7.4%; laryngospasm in 0.5%; and gastric contents inside the bowl in 0.2% of patients. CONCLUSIONS: The i-gel Plus appears to be an effective supraglottic airway device that is associated with a high insertion success rate and a reasonably low incidence of complications.

5.
Sci Rep ; 14(1): 19579, 2024 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-39179661

RESUMEN

To date, endotracheal tube (ETT) remains the mainstream for preterm infants receiving general anesthesia. We aim to compare the perioperative respiratory adverse events between using supraglottic airway device (SAD) and ETT in former preterm infants receiving general anesthesia. Former preterm infants below 52 weeks of postmenstrual age scheduled for herniorrhaphy were randomized to receive SAD or ETT for general anesthesia. Infants with severe congenital cardiopulmonary disease, prolonged oxygen or mechanical ventilation dependence, and recent respiratory tract infection were excluded. Muscle relaxant agents and opioids were avoided in this study. 40 infants were assigned into SAD or ETT groups. Infants in the SAD group had a much lower rate of intraoperative desaturation than those in the ETT group (21.1% vs. 73.7%, p = 0.003). Incidences of other intraoperative and postoperative 24-h respiratory adverse events were similar between groups, including laryngospasm/bronchospasm, cough and stridor during anesthesia, and postoperative apnea, bradycardia, and supplemental oxygen use. All participants were extubated successfully in the operation room. SAD is recommended in former preterm infants receiving general anesthesia for herniorrhaphy in their early infancy as it much decreases the incidence of intraoperative desaturation compared to ETT.


Asunto(s)
Anestesia General , Recien Nacido Prematuro , Intubación Intratraqueal , Humanos , Anestesia General/efectos adversos , Anestesia General/métodos , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/instrumentación , Intubación Intratraqueal/métodos , Femenino , Masculino , Recién Nacido , Lactante , Máscaras Laríngeas/efectos adversos
6.
Indian J Anaesth ; 68(7): 637-643, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39081918

RESUMEN

Background and Aims: Postoperative sore throat (POST) can be as high as 42% in supraglottic devices. LMA® Protector™ is a novel second-generation laryngeal mask airway (LMA) with Cuff Pilot™ technology that allows continuous cuff pressure monitoring. Elevated cuff pressure is a risk factor for POST in supraglottic devices, so we conducted this study to determine whether continuous cuff pressure monitoring can alleviate POST. Methods: This randomised double-blinded clinical trial compared the incidence of sore throat between LMA® Protector™ and LMA® ProSeal™ and was conducted in 118 patients scheduled for elective short surgical procedures. They were randomised to either LMA® Protector™ (Group PT) or LMA® ProSeal™ (Group P). The airway was secured with either of the two devices. The primary outcome was the incidence of sore throat at 1, 6, and 24 hours postoperatively and compared using the Chi-square test along with other parameters like first attempt success rate and blood staining of the device. The time taken for insertion and oropharyngeal seal pressure were compared using an independent t-test. Results: The incidence of POST was low with Group PT (12%) compared to Group P (28.8%) (P = 0.005). The mean oropharyngeal seal pressure was significantly higher in Group PT than in Group P [33.72 (3.07) versus 27.72 (3.88) cm of H2O], P < 0.005. The first attempt success rate was 81.2% and 100% in LMA® Protector™ versus LMA® ProSeal™. Conclusion: LMA® Protector™ had a reduced incidence of POST compared to LMA ProSeal. However, a longer insertion time and difficult placement may be a concern.

7.
BMC Anesthesiol ; 24(1): 229, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38987667

RESUMEN

BACKGROUND: This study evaluated the effect of head rotation on the first-attempt success rate of i-gel insertion, aiming to alleviate the effect of gravity on the tongue and reduce resistance between the device and the tongue. METHODS: Adult surgical patients were randomized to standard and head rotation technique groups. In the head rotation technique group, patients' heads were maximally rotated to the left before i-gel insertion. The primary endpoint was the first-attempt success rate. Secondary endpoints included the success rate within two attempts (using the allocated technique), time required for successful i-gel placement within two attempts, and success rate at the third attempt (using the opposite technique). RESULTS: Among 158 patients, the head rotation technique group showed a significantly higher first-attempt success rate (60/80, 75.0%) compared to the standard technique group (45/78, 57.7%; P = 0.021). The success rate within two attempts was similar between the groups (95.0% vs. 91.0%, P = 0.326). The time required for successful i-gel placement was significantly shorter in the head rotation technique (mean [SD], 13.4 [3.7] s vs. 16.3 [7.8] s; P = 0.030). When the head rotation technique failed, the standard technique also failed in all cases (n = 4), whereas the head rotation technique succeeded in five out of the seven patients where the standard technique failed. CONCLUSIONS: The head rotation technique significantly improved the first-attempt success rate and reduced the time required for successful i-gel insertion. It was effective when the standard technique failed. The head rotation technique may be an effective primary or alternative method for i-gel insertion. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov (NCT05201339).


Asunto(s)
Cabeza , Humanos , Masculino , Femenino , Rotación , Persona de Mediana Edad , Adulto , Intubación Intratraqueal/métodos , Intubación Intratraqueal/instrumentación , Anciano , Posicionamiento del Paciente/métodos , Lengua
8.
Neonatology ; : 1-11, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38834044

RESUMEN

INTRODUCTION: Laryngeal mask airway (LMA) use in neonatal resuscitation is limited despite existing evidence and recommendations. This survey investigated the knowledge and experience of healthcare providers on the use of the LMA and explored barriers and solutions for implementation. METHODS: This online, cross-sectional survey on LMA in neonatal resuscitation involved healthcare professionals of the Union of European Neonatal and Perinatal Societies (UENPS). RESULTS: A total of 858 healthcare professionals from 42 countries participated in the survey. Only 6% took part in an LMA-specific course. Some delivery rooms were not equipped with LMA (26.1%). LMA was mainly considered after the failure of a face mask (FM) or endotracheal tube (ET), while the first choice was limited to neonates with upper airway malformations. LMA and FM were considered easier to position but less effective than ET, while LMA was considered less invasive than ET but more invasive than FM. Participants felt less competent and experienced with LMA than FM and ET. The lack of confidence in LMA was perceived as the main barrier to its implementation in neonatal resuscitation. More training, supervision, and device availability in delivery wards were suggested as possible actions to overcome those barriers. CONCLUSION: Our survey confirms previous findings on limited knowledge, experience, and confidence with LMA, which is usually considered an option after the failure of FM/ET. Our findings highlight the need for increasing the availability of LMA in delivery wards. Moreover, increasing LMA training and having an LMA expert supervisor during clinical practice may improve the implementation of LMA use in neonatal clinical practice.

9.
Cureus ; 16(4): e58629, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38770453

RESUMEN

Background and aim A novel supraglottic airway device of the second generation is the Ambu® Aura-i™. It is designed to accommodate standard cuffed tracheal tubes and is phthalate-free and compatible with MRI. The primary objectives of the research were to examine the properties and efficiency of Ambu® Aura-i™ as a means of enabling fiberoptic-guided intubation, the view of the glottis during fiber optic examination, the duration of intubation in fiber optic bronchoscopy, the ease of intubation, the success rate of intubation, and the duration for device removal from the tracheal tube. Methodology A hospital-based descriptive observational study was conducted with 80 patients. An adequately sized Ambu® Aura-i™ was placed after general anesthesia was induced. Following a fiberoptic examination of the view of the glottis through the Ambu® Aura-i™, the trachea was intubated under fiberoptic guidance. The Ambu® Aura-i™ insertion time, glottic view grading, ease of intubation, and time required for fiberoptic-guided intubation were recorded. Also, the time taken to remove the Ambu® Aura-i™ was documented. Results Similar levels of ease were experienced by both groups after inserting the Ambu® Aura-i™, being easy in both group 1 (37/40) and in group 2 (38/40). In group 1, the average time taken to insert the Ambu® Aura-i™ was 13.53±1.91 seconds, while in group 2, it was 13.98±2.4 seconds. The average time required for fiberoptic-guided intubation was found to be 14.95±1.85 seconds in group 1 and 14.15±1.37 seconds in group 2, indicating a statistically negligible variation. Conclusion The low cost of Ambu® Aura-i™, size suitability and availability for almost all age groups, compatibility with MRI machines, and availability in phthalate-free versions contribute to it being a more appealing and useful ventilatory device, as well as an intubation tool for both normal and emergency airway management.

10.
Turk J Emerg Med ; 24(2): 97-102, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38766418

RESUMEN

OBJECTIVES: Supraglottic airway (SGA) devices are good alternatives for failed intubations or difficult airways. The aim of our study was to compare the success of intubation with SGA devices such as LMA Fastrach® (LMA Fastrach), Ambu Aura-i® (Aura-i), and Cookgas Air-Q® (Air-Q) in an airway manikin by novice practitioners. METHODS: This study was conducted in a randomized crossover design using a manikin model. Following training on the equipment used, 36 6th-year medical students were randomized into six groups. Participants performed three stages of intubation as follows: the first stage (1S) as SGA insertion, the second stage (2S) as intubation through the SGA, and the third stage (3S) as the removal of the SGA over the intubation tube. The primary outcomes were intubation success and duration. RESULTS: The successful intubation rate (Stage 1S + 2S + 3S) was 100% for LMA Fastrach and Air-Q and 83.3% for Aura-i (P = 0.002). The median time to intubation was 54.4 s, 55.8 s, and 58.7 s for LMA Fastrach, Aura-i, and Air-Q, respectively (P = 0.794). CONCLUSION: Our study shows that novice practitioners can proficiently utilize LMA Fastrach, Air-Q, and Aura-i as SGAs in airway management. LMA Fastrach and Air-Q are more successful for endotracheal intubation than Aura-i. While the successful intubation time with SGA is similar for all three devices, the successful SGA insertion time is shorter with LMA Fastrach and Aura-i compared to Air-Q. Practitioners preferred LMA Fastrach and Air-Q more than Aura-i.

11.
J Am Coll Emerg Physicians Open ; 5(2): e13150, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38576603

RESUMEN

Objective: Unlike randomized controlled trials, practical real-world studies can offer important information about implementation of prehospital interventions, particularly in community settings where there may be reluctance to adopt new practices. We present the results of a natural experiment that was driven by mandated COVID-19 pandemic-driven shift from endotracheal intubation (ETI) to the i-gel® supraglottic airway (SGA) as a primary advanced airway management device in the prehospital setting to reduce emergency medical services (EMS) personnel exposure to potentially infectious secretions. The objective was to compare first-pass success and timing to successful airway placement between ETI and the i-gel® SGA under extenuating circumstances. Methods: This pre/post study compared airway placement metrics in prehospital patients requiring advance airway management for non-trauma-related conditions. Data from EMS records were extracted over 2 years, 12 months pre-pandemic, and 12 months post-pandemic. During the pre-COVID-19 year, the EMS protocols utilized ETI as the primary advanced airway device (ETI group). Post-pandemic paramedics were mandated to utilize i-gel® SGA as the primary advanced airway device to reduce exposure to secretions (SGA group). Results: There were 199 adult patients, 83 (42%) in the ETI group and 116 (58%) in the SGA group. First-pass success was significantly higher with SGA 96% (92%-99%) than ETI 68% (57%-78%) with paramedics citing the inability to visualize the airway in 52% of ETI cases. Time to first-pass success was significantly shorter in the SGA group (5.9 min [5.1-6.7 min]) than in the ETI group (8.3 min [6.9-9.6 min]), as was time to overall successful placement at 6.0 min (5.1-6.8 min) versus 9.6 min (8.2-11.1 min), respectively. Multiple placement attempts were required in 26% of ETI cases and 1% of the SGA cases. There were no statistically significant differences in the number and types of complications between the cohorts. Return of spontaneous circulation (on/before emergency department [ED] arrival), mortality at 28 days, intensive care unit length of stay, or ventilator-free days between the groups were not statistically different between the groups. Conclusion: In this natural experiment, the SGA performed significantly better than ETI in first-pass airway device placement success and was significantly faster in achieving first-pass success, and overall airway placement, thus potentially reducing exposure to respiratory pathogens. Practical real-world studies can offer important information about implementation of prehospital interventions, particularly in community settings and in systems with a low frequency of tracheal intubations.

12.
Can J Anaesth ; 71(9): 1251-1260, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38671251

RESUMEN

PURPOSE: Remimazolam is a recently developed ultra-short-acting benzodiazepine used for anesthesia induction and maintenance. Nevertheless, the effective bolus dose of remimazolam for i-gel® (Intersurgical Ltd., Wokingham, Berkshire, UK) insertion without the use of neuromuscular blocking agents (NMBAs) has not been well established. METHODS: This study included 25 adult patients scheduled for surgery under general anesthesia who were eligible for i-gel use. Anesthesia was induced with predetermined bolus doses of remimazolam, starting at 0.3 mg·kg-1 for the first patient, without the use of NMBAs. All patients concurrently received remifentanil using target-controlled infusion (TCI) at a fixed effect-site concentration (Ce) of 3.0 ng·mL-1. Insertion of the i-gel was attempted 90 sec after remimazolam administration, and insertion conditions were assessed. Subsequent doses of remimazolam were decreased or increased by 0.05 mg·kg-1, depending on the success or failure of i-gel insertion. RESULTS: The mean (standard deviation) 50% effective dose (ED50) of a remimazolam bolus for successful i-gel insertion as determined by the modified Dixon's up-and-down method was 0.100 (0.027) mg·kg-1. The ED50 and ED95 estimated by isotonic regression were 0.111 (83% confidence interval [CI], 0.096 to 0.131) mg·kg-1 and 0.182 (95% CI, 0.144 to 0.195) mg·kg-1, respectively. None of the patients required treatment for hypotension or bradycardia during anesthesia induction. CONCLUSION: Based on the ED95 of remimazolam bolus dose determined in our study, we recommend using 0.182 mg·kg-1 of remimazolam in combination with remifentanil TCI at a Ce of 3.0 ng·mL-1 for successful i-gel insertion without NMBAs in adult patients. This regimen seems effective with a low risk of hemodynamic instability during anesthesia induction. STUDY REGISTRATION: ClinicalTrials.gov ( NCT05298228 ); first submitted 6 March 2022.


RéSUMé: OBJECTIF: Le remimazolam est une benzodiazépine à action ultra-courte récemment mise au point et utilisée pour l'induction et le maintien de l'anesthésie. Toutefois, la dose efficace en bolus de remimazolam pour l'insertion de l'i-gel® (Intersurgical Ltd., Wokingham, Berkshire, Royaume-Uni) sans utiliser de bloqueurs neuromusculaires (BNM) n'a pas été bien établie. MéTHODE: Cette étude a inclus 25 adultes devant bénéficier d'une intervention chirurgicale sous anesthésie générale qui étaient éligibles à l'utilisation d'un i-gel. L'anesthésie a été induite avec des doses prédéterminées en bolus de remimazolam, à partir de 0,3 mg·kg−1 pour la première personne, sans utiliser de BNM. Toutes les personnes anesthésiées ont reçu en parallèle du rémifentanil en perfusion à objectif de concentration à une concentration au site effecteur (Ce) de 3,0 ng·mL−1. L'insertion de l'i-gel a été tentée 90 secondes après l'administration de remimazolam, et les conditions d'insertion ont été évaluées. Les doses subséquentes de remimazolam ont été diminuées ou augmentées de 0,05 mg·kg−1, en fonction du succès ou de l'échec de l'insertion de l'i-gel. RéSULTATS: La dose efficace moyenne (écart type) de 50 % (DE50) d'un bolus de remimazolam pour une insertion réussie de l'i-gel, telle que déterminée par la méthode « up-and-down ¼ de Dixon modifiée, était de 0,100 (0,027) mg·kg−1. Les DE50 et DE95 estimées par régression isotonique étaient de 0,111 (intervalle de confiance [IC] à 83 %, 0,096 à 0,131) mg·kg−1 et 0,182 (IC 95 %, 0,144 à 0,195) mg·kg−1, respectivement. Aucun·e patient·e n'a eu besoin de traitement pour une hypotension ou une bradycardie pendant l'induction de l'anesthésie. CONCLUSION: D'après la DE95 de la dose de remimazolam en bolus déterminée dans notre étude, nous recommandons d'utiliser 0,182 mg·kg−1 de remimazolam en association avec une perfusion à objectif de concentration de rémifentanil à une Ce de 3,0 ng·mL−1 pour réussir l'insertion de l'i-gel sans BNM chez la patientèle adulte. Ce schéma semble efficace avec un faible risque d'instabilité hémodynamique lors de l'induction de l'anesthésie. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT05298228); première soumission le 6 mars 2022.


Asunto(s)
Benzodiazepinas , Relación Dosis-Respuesta a Droga , Remifentanilo , Humanos , Masculino , Femenino , Persona de Mediana Edad , Benzodiazepinas/administración & dosificación , Adulto , Anciano , Remifentanilo/administración & dosificación , Anestesia General/métodos , Hipnóticos y Sedantes/administración & dosificación , Intubación Intratraqueal/métodos
13.
J Emerg Med ; 66(4): e470-e476, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38461134

RESUMEN

BACKGROUND: Tracheal intubation is the gold standard for airway management in emergency medicine, but more difficult to apply for inexperienced individuals than laryngeal mask airway (LMA). OBJECTIVE: The aim of our study was to investigate if inexperienced individuals are able to secure the airway with the help of LMA after a short introduction. A second aim was to evaluate Thiel-fixed specimens against unfixed ones. METHODS: In a body donor model, LMA application was evaluated between medical students without previous airway experience and anesthesiologists by comparing the sealing of the larynx using a water column applied to the esophagus. RESULTS: LMAs were successfully applied in 46 out of 55 (83.6%) attempts by medical students and in 30 out of 39 (76.9%) attempts by anesthesiologists. Among medical students, 14.1% of all LMA applications were primarily leaky, compared with 18.8% in anesthesiologists. Esophageal sealing was better in Thiel-fixed specimens (leakage 10.9%) compared with unfixed specimens (leakage 22.9%). Our data showed no significant difference between anesthesiologists and medical students in terms of sealing of LMA. Therefore, we conclude that medical students without previous airway experience can quickly learn to apply LMA sufficiently and thus, achieve aspiration protection similar to anesthesiologists. CONCLUSION: Medical students without previous airway experience can successfully insert LMAs after a short introduction. Thiel-fixed specimens are suitable for studies as well as for training in LMA application.


Asunto(s)
Máscaras Laríngeas , Humanos , Anestesiólogos , Intubación Intratraqueal , Manejo de la Vía Aérea , Esófago
14.
Can J Anaesth ; 71(7): 996-1003, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38507025

RESUMEN

PURPOSE: Anesthesiologists can use supraglottic airway devices as a rescue technique for failed intubation even in patients with an increased risk of gastric regurgitation. In this randomized study, we aimed to evaluate the effects of cricoid pressure and paratracheal pressure on placement of the i-gel® (Intersurgical Ltd., Wokingham, Berkshire, UK). METHODS: After induction of anesthesia in 76 adult patients, we inserted the i-gel under paratracheal or cricoid pressure, and assessed the success rate of i-gel insertion, resistance during insertion, time required for insertion, accuracy of the insertion location, tidal volumes, and peak inspiratory pressure with or without each maneuver after i-gel insertion. RESULTS: The overall success rate of insertion was significantly higher under paratracheal pressure than under cricoid pressure (36/38 [95%] vs 27/38 [71%], respectively; difference, 24%; 95% confidence interval [CI], 8 to 40; P = 0.006]. Resistance during insertion was significantly lower under paratracheal pressure than under cricoid pressure (P < 0.001). The time required for insertion was significantly shorter under paratracheal pressure than under cricoid pressure (median [interquartile range], 18 [15-23] sec vs 28 [22-38] sec, respectively; difference in medians, -10; 95% CI, -18 to -4; P < 0.001). Fibreoptic examination of the anatomical alignment of the i-gel in the larynx revealed no significant difference in the accuracy of the insertion location between the two maneuvers (P = 0.31). The differences in tidal volume and peak inspiratory pressure with or without the maneuvers were significantly lower with paratracheal pressure than with cricoid pressure (P = 0.003, respectively). CONCLUSIONS: Insertion of the i-gel supraglottic airway was significantly more successful, easier, and faster while applying paratracheal pressure than cricoid pressure. STUDY REGISTRATION: ClinicalTrials.gov (NCT05377346); first submitted 11 May 2022.


RéSUMé: OBJECTIF: Les anesthésiologistes peuvent utiliser des dispositifs supraglottiques comme technique de sauvetage en cas d'échec de l'intubation, même chez les personnes présentant un risque accru de régurgitation gastrique. Dans cette étude randomisée, nous avons cherché à évaluer les effets de la pression cricoïdienne et de la pression paratrachéale sur le positionnement du dispositif i-gel® (Intersurgical Ltd., Wokingham, Berkshire, Royaume-Uni). MéTHODE: Après l'induction de l'anesthésie chez 76 adultes, nous avons inséré l'i-gel en utilisant une pression paratrachéale ou cricoïdienne, et avons évalué le taux de réussite de l'insertion de l'i-gel, la résistance pendant l'insertion, le temps nécessaire à l'insertion, la précision de l'emplacement d'insertion, les volumes courants ainsi que la pression inspiratoire maximale avec ou sans chacune des manœuvres après l'insertion de l'i-gel. RéSULTATS: Le taux global de réussite de l'insertion était significativement plus élevé avec une pression paratrachéale qu'avec une pression cricoïdienne (36/38 [95 %] vs 27/38 [71 %], respectivement; différence, 24 %; intervalle de confiance [IC] à 95 %, 7,6 à 39,8; P = 0,006]. La résistance lors de l'insertion était significativement plus faible en utilisant une pression paratrachéale par rapport à une pression cricoïdienne (P < 0,001). Le temps nécessaire à l'insertion était significativement plus court après avoir exercé une pression paratrachéale plutôt que cricoïdienne (médiane [écart interquartile], 18,4 [15,3­23,1] secondes vs 28,4 [22,3 à 37,8] secondes, respectivement; différence dans les médianes, −10,0; IC 95 %, −18,4 à −3,6; P < 0,001). L'examen par fibre optique de l'alignement anatomique de l'i-gel dans le larynx n'a révélé aucune différence significative dans la précision de l'emplacement d'insertion entre les deux manœuvres (P = 0,31). Les différences de volume courant et de pression inspiratoire maximale avec ou sans les manœuvres étaient significativement plus faibles avec la pression paratrachéale qu'avec la pression cricoïdienne (P = 0,003, respectivement). CONCLUSION: L'insertion du dispositif supraglottique i-gel a été significativement plus réussie, plus facile et plus rapide lors de l'application d'une pression paratrachéale que d'une pression cricoïdienne. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT05377346); soumis pour la première fois le 11 mai 2022.


Asunto(s)
Cartílago Cricoides , Intubación Intratraqueal , Máscaras Laríngeas , Presión , Humanos , Masculino , Femenino , Persona de Mediana Edad , Intubación Intratraqueal/métodos , Intubación Intratraqueal/instrumentación , Adulto , Anciano , Volumen de Ventilación Pulmonar
16.
Cureus ; 16(2): e54703, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38524051

RESUMEN

Tracheal and subglottic stenoses are inflammatory conditions that can arise from a variety of potential etiologies, most commonly as a result of iatrogenic airway injury due to endotracheal intubation. Significant stenosis requires management by endoscopy or surgical resection. We describe a case of recurrent subglottic cuff stenosis with an episode of sudden desaturation in a 25-year-old female. The management involved balloon dilatation, laser ablation, and topical mitomycin C application through a flexible fiberoptic bronchoscope. Ensuring safe gas exchange during bronchoscopy was a priority, and this was achieved by maintaining ventilation with a supraglottic airway device, which was inserted in an awake patient after adequate tropicalization of the oral cavity. The intervention successfully helped in the management of stenosis and also addressed the complication of sudden complete airway collapse due to sedation.

17.
J Pers Med ; 14(3)2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38541053

RESUMEN

(1) Background: Supraglottic airway devices (SAD) have been used in children and adolescents undergoing adenotonsillectomies under general anesthesia. This systematic review and meta-analysis investigate the safety and efficacy of using SADs when compared to an endotracheal tube (ETT). (2) Methods: After registering with PROSPERO, databases like PubMed, Scopus, OviD, CINAHL, and Cochrane Library were searched using relevant keywords from the year 2000. We used RoB-2 for risk-of-bias assessment, GRADE for assessing the quality of evidence, RevMan 5.2 for qualitative meta-analysis, and trial sequential analysis (TSA) to corroborate the significant findings of meta-analysis. (3) Results: Out of 200 studies, 5 randomized-controlled trials fulfilled inclusion criteria. The quality of evidence was moderate for laryngospasm, low for airway device failure, and very low for recovery time. The incidence of laryngospasm was comparable between SADs and ETT (RR: 0.80, 95% CI-0.36, 1.80, p = 0.59). The incidence of airway device failure was significantly higher with SADs than ETT (RR: 11.29, 95% CI: 2.73, 46.66, p = 0.0008). The postoperative recovery time was significantly less with SADs than with ETT use (MD: -4.33, 95% CI: -5.28, -3.39, p < 0.0001), which was confirmed by the TSA. (4) Conclusions: The results of this review suggests that use of SADs can provide a lesser postoperative recovery time and comparable incidence of laryngospasm, with a higher incidence of failure of SAD when compared to ETT. Use of SAD for pediatric and adolescent adenotonsillectomies should be individualized based on patient characteristics, and on the expertise of the anesthesiologist and the surgeons involved.

18.
Cureus ; 16(1): e53254, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38435921

RESUMEN

Tracheostomy is commonly performed in patients to secure the airway. There are known early and late complications related to tracheostomy. Few case reports have described the rupture of the stem of the tracheostomy tube and its migration into the tracheobronchial tree. Here we describe a pediatric case with a broken stem of the tracheostomy tube in the trachea, acting as a foreign body and causing mild respiratory distress. The patient was successfully managed with neck exploration under general anesthesia using a supraglottic airway device in low-resource settings. In addition, we have described the potential problems that may be faced while managing the airway of such patients and how to deal with these complications.

19.
J Clin Med ; 13(3)2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38337364

RESUMEN

(1) Background: The physiological and pharmacological variations between men and women are known to influence drug efficacy. The objective of this study was to determine the 50% and 95% effective doses (ED50 and ED95) of remimazolam required for i-gel supraglottic airway (ISA) insertion under remifentanil infusion without neuromuscular blocking agents (NMBAs) in both males and females. (2) Methods: Patients aged 19-65 years, scheduled for general anesthesia using ISA, were enrolled in this study. Patients were divided into two groups based on their sex. The anesthesia process began with a remifentanil infusion targeting an effect-site concentration of 3.0 ng/mL, accompanied by a remimazolam injection. The initial remimazolam dose was 0.25 mg/kg, and it was adjusted with a step size of 0.05 mg/kg based on the outcome of ISA insertion in the preceding patient. (3) Results: The ED50 of remimazolam (mean ± standard error) was 0.28 ± 0.02 mg/kg in the male group and 0.18 ± 0.02 mg/kg in the female group (p < 0.001). Additionally, ED95, which was calculated using the isotonic regression method, was significantly comparable between the male and female groups (male: 0.35 mg/kg, 95% confidence interval [CI] = 0.34-0.35; female: 0.29 mg/kg, 95% CI = 0.25-0.30). (4) Conclusions: This study showed that both the ED50 and the ED95 of remimazolam for successful ISA insertion was higher for men than that for women. Therefore, while using remimazolam alongside remifentanil infusion without NMBAs for ISA insertion, one should consider the patient's sex for appropriate dosing.

20.
Am J Cancer Res ; 14(1): 16-32, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38323274

RESUMEN

The escalating airway management demands of cancer patients have prompted us to continually curate airway devices, with supraglottic airway devices (SADs) playing a significant role in this regard. SADs serve as instrumental tools for maintaining an open upper airway. Since the inception of the earliest SADs in the early 1980s, an array of advanced and enhanced second-generation devices have been employed in clinical settings. These upgraded SADs integrate specific features designed to enhance positive-pressure ventilation and mitigate the risk of aspiration. Nowadays, they are extensively used in general anesthesia procedures and play a critical role in difficult airway management, pre-hospital care, and emergency medicine. In certain situations, SADs may be deemed a superior alternative to endotracheal tube (ETT) and can be employed in a broader spectrum of surgical and non-surgical cases. This review provides an overview of the current evidence, a summary of classifications, relevant application scenarios, and areas for improvement in the development or clinical application of future SADs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA