1.
Eur Arch Otorhinolaryngol ; 280(10): 4371-4379, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37010602

RESUMEN

PURPOSE: Minimally invasive cochlear implant surgery using a micro-stereotactic surgical targeting system with on-site moulding of the template aims for a reliable, less experience-dependent access to the inner ear under maximal reduction of trauma to anatomic structures. We present an accuracy evaluation of our system in ex-vivo testing. METHODS: Eleven drilling experiments were performed on four cadaveric temporal bone specimens. The process involved preoperative imaging after affixing the reference frame to the skull, planning of a safe trajectory preserving relevant anatomical structures, customization of the surgical template, execution of the guided drilling and postoperative imaging for determination of the drilling accuracy. Deviation between the drilled and desired trajectories was measured at different depths. RESULTS: All drilling experiments were successfully performed. Other than purposely sacrificing the chorda tympani in one experiment, no other relevant anatomy, such as facial nerve, chorda tympani, ossicles or external auditory canal were harmed. Deviation between the desired and achieved path was found to be 0.25 ± 0.16 mm at skulls' surface and 0.51 ± 0.35 mm at the target level. The closest distance of the drilled trajectories' outer circumference to the facial nerve was 0.44 mm. CONCLUSIONS: We demonstrated the usability for drilling to the middle ear on human cadaveric specimen in a pre-clinical setting. Accuracy proved to be suitable for many applications such as procedures within the field of image-guided neurosurgery. Promising approaches to reach sufficient submillimetre accuracy for CI surgery have been outlined.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cirugía Asistida por Computador , Humanos , Cirugía Asistida por Computador/métodos , Implantación Coclear/métodos , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/cirugía , Cadáver
2.
Acta Neurochir (Wien) ; 165(2): 549-554, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36585476

RESUMEN

BACKGROUND: Laser interstitial thermal therapy (LITT) is a stereotactic neurosurgical procedure used to treat neoplastic and epileptogenic lesions in the brain. A variety of advanced technological instruments such as frameless navigation systems, robotics, and intraoperative MRI are often described in this context, although the surgical procedure can also be performed using a standard stereotactic setup and a diagnostic MRI suite. METHODS: We report on our experience and a surgical technique using a Leksell stereotactic frame and a diagnostic MRI suite to perform LITT. CONCLUSION: LITT can be safely performed using the Leksell frame and a diagnostic MRI suite, making the technique available even to neuro-oncology centers without advanced technological setup.


Asunto(s)
Neoplasias Encefálicas , Terapia por Láser , Humanos , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Terapia por Láser/métodos , Procedimientos Neuroquirúrgicos/métodos , Imagen por Resonancia Magnética/métodos , Rayos Láser
3.
Pak J Med Sci ; 38(7): 1796-1801, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36246717

RESUMEN

Objectives: To compare the clinical efficacy of robot of stereotactic assistant (ROSA) and frame-assisted stereotactic drilling and drainage for intracerebral hematoma in hypertensive intracerebral hemorrhage (HICH). Methods: A total of 142 patients with HICH treated in Baoding First Central Hospital from January 2018 to January 2020 were selected and divided into two groups using a random number table. The ROSA group was treated with a robot of stereotactic assistant, while the frame group underwent frame-assisted stereotactic drilling and drainage for intracerebral hematoma. Surgical duration, postoperative extubation time and complications were compared between the two groups. Venous blood (5 mL) was collected before and three days after surgery. The levels of inflammatory factors [tumor necrosis factor-α (TNF-α), high-sensitivity C-reactive protein (hs-CRP) and interleukin-6 (IL-6)], as well as neurological function indexes [neuron-specific enolase (NSE), nerve growth factor (NGF) and brain-derived neurotrophic factor (BDNF)] were detected by enzyme-linked immunosorbent assay. Results: The surgical duration, postoperative extubation time, and incidences of infection and postoperative rehemorrhage in the ROSA group were lower than those in the frame group (P < 0.05). In the ROSA group, postoperative TNF-α, hs-CRP, IL-6 and NSE levels were significantly lower while NGF and BDNF levels were higher than those in the frame group (all P < 0.05). Conclusion: Compared with frame-assisted stereotactic drilling and drainage for intracerebral hematoma, ROSA in HICH treatment shortens the surgical duration and postoperative extubation time, reduces the risks of infection and rehemorrhage and decreases inflammatory level, which is helpful for the recovery of neurological function.

4.
Cureus ; 14(8): e28387, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36176855

RESUMEN

Frame-based stereotactic localization is an important step for targeting during a surgical procedure. The motion may cause artifacts in this step reducing the accuracy of surgical targeting. While modeling of motion in real-life scenarios may be difficult, herein we analyzed the case where motion was suspected to impact the localization step. In this case, a scan with and without motion was performed with a 3N localizer, allowing for a thorough analysis. Pseudo-bending of straight rods was seen when analyzing the data. This pseudo-bending appears to occur because head-frame motion during imaging acquisition decreases the accuracy of the subsequent reconstruction, which depends on Digital Imaging and Communications in Medicine (DICOM) metadata to specify the slice-to-slice location that assumes embedded object stability. Comparison of single-slice and multi-slice stereotactic localization allowed for comparative errors for each slice in a volume. This comparative error demonstrated low error when the patient was under general anesthesia and presumed not to have moved, whereas a higher error was present during the scan with motion. Pseudo-bending can be corrected by using only localizer fiducial-based information to reorient the pixels in the volume, thus creating a reoriented localizer scan. Finally, targeting demonstrated a low error of 0.1 mm (+/- 0.1 mm) using this reoriented localizer scan, signifying that this method could be used to improve or recover from motion problems. Finally, it is concluded that stability and elimination of motion for all images utilized for stereotactic surgery are critical to ensure the best possible accuracy for the procedure.

5.
Front Neurorobot ; 16: 762317, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35515711

RESUMEN

Background: The development of robotic systems has provided an alternative to frame-based stereotactic procedures. The aim of this experimental phantom study was to compare the mechanical accuracy of the Robotic Surgery Assistant (ROSA) and the Leksell stereotactic frame by reducing clinical and procedural factors to a minimum. Methods: To precisely compare mechanical accuracy, a stereotactic system was chosen as reference for both methods. A thin layer CT scan with an acrylic phantom fixed to the frame and a localizer enabling the software to recognize the coordinate system was performed. For each of the five phantom targets, two different trajectories were planned, resulting in 10 trajectories. A series of five repetitions was performed, each time based on a new CT scan. Hence, 50 trajectories were analyzed for each method. X-rays of the final cannula position were fused with the planning data. The coordinates of the target point and the endpoint of the robot- or frame-guided probe were visually determined using the robotic software. The target point error (TPE) was calculated applying the Euclidian distance. The depth deviation along the trajectory and the lateral deviation were separately calculated. Results: Robotics was significantly more accurate, with an arithmetic TPE mean of 0.53 mm (95% CI 0.41-0.55 mm) compared to 0.72 mm (95% CI 0.63-0.8 mm) in stereotaxy (p < 0.05). In robotics, the mean depth deviation along the trajectory was -0.22 mm (95% CI -0.25 to -0.14 mm). The mean lateral deviation was 0.43 mm (95% CI 0.32-0.49 mm). In frame-based stereotaxy, the mean depth deviation amounted to -0.20 mm (95% CI -0.26 to -0.14 mm), the mean lateral deviation to 0.65 mm (95% CI 0.55-0.74 mm). Conclusion: Both the robotic and frame-based approach proved accurate. The robotic procedure showed significantly higher accuracy. For both methods, procedural factors occurring during surgery might have a more relevant impact on overall accuracy.

6.
J Appl Clin Med Phys ; 23(7): e13637, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35635549

RESUMEN

PURPOSE: To assess differences between frame-based and cone beam computed tomography (CBCT)-defined stereotactic space and to identify predictors of the observed findings. METHODS AND MATERIALS: Differences between frame-based and CBCT-defined stereotactic space after image co-registration were reviewed for 529 patients. Treatment planning system reported the information about the shifts in X, Y, and Z coordinates of the center of the stereotactic space (i.e., coordinate X = 100 mm, Y = 100 mm, and Z = 100 mm) defined by the frame, and the maximum shot displacement (MSD) in mm. We collected the potential predictors of the differences. In total, 19 factors were investigated. We used multiple linear regression to evaluate associations with the increased differences. RESULTS: Rotational and translational shifts greater than 1° and 1 mm, respectively, were observed in 2.6% of patients. At the same time, a decrease in tumor coverage of more than 5% was detected in 8.3% of cases. It was revealed that the higher fiducial errors (both mean and maximum), the greater weight of the patient, and the lower Karnofsky Performance Scale were predictors of increased rotational, translational shifts, and the MSD.


Asunto(s)
Neoplasias , Radiocirugia , Tomografía Computarizada de Haz Cónico Espiral , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Imagenología Tridimensional/métodos , Neoplasias/diagnóstico por imagen , Neoplasias/radioterapia , Neoplasias/cirugía , Radiocirugia/métodos
7.
Cureus ; 14(3): e23279, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35449621

RESUMEN

Frame-based stereotactic localization generally assumes that all required fiducials are present in a single-slice image which can then be used to form targeting coordinates. Previously, we have published the use of novel localizers and mathematics that can improve stereotactic localization. As stereotactic procedures include numerous imaging slices, we sought to investigate, develop, and test techniques that utilize multiple slices for stereotactic localization and provide a solution for a parallel bipanel N-localizer.  Several multi-slice equations were tested. Specifically, multi-slice stereotactic matrices (ms-SM) and multi-slice normal to parallel planes (ms-nPP) were of particular interest. Bipanel (2N) and tripanel (3N) localizer images were explored to test approaches for stereotactic localization. In addition, combination approaches using single-slice stereotactic matrices (ss-SM) and multi-slice methods were tested. Modification of ss-SM to form ms-SM was feasible. Likewise, a method to determine ms-nPP was developed. For the special case of the parallel bipanel N-localizer, single-slice and multi-slice methods fail, but a novel non-linear solution is a robust solution for ms-nPP. Several methods for single-slice and multi-slice stereotactic localization are described and can be adapted for nearly any stereotactic system. It is feasible to determine ms-SM and ms-nPP. In particular, these methods provide an overdetermined means to calculate the vertical z, which is determined for a tripanel system using single-slice methods. In addition, the multi-slice methods can be used for extrapolation outside of the localizer space. Importantly, a novel non-linear solution can be used for parallel bipanel N-localizer systems, where other methods fail. Finally, multi-slice stereotactic localization assumes strict patient and imaging system stability, which should be carefully assessed for each case.

8.
Cureus ; 13(9): e17905, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34660100

RESUMEN

Image guidance for frame-based stereotaxis is facilitated by incorporating three to four Sturm-Pastyr (SP) localizers into a stereotactic frame. Typically, each SP localizer enables the calculation of one set of [Formula: see text] coordinates in the three-dimensional coordinate system of the stereotactic frame, given three sets of [Formula: see text] coordinates created by the SP localizer in the two-dimensional coordinate system of a computed tomography (CT) image. Bouza and Brown propose formulas to calculate three sets of [Formula: see text] coordinates for each SP localizer. Monte Carlo (MC) simulation compares the accuracy of the new formulation to the accuracy of the original SP formulation that calculates only one set of [Formula: see text] coordinates for each SP localizer. Monte Carlo simulation reveals that the calculation of three sets of [Formula: see text] coordinates instead of only one set improves the accuracy of image guidance.

9.
Cureus ; 13(6): e15620, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34277238

RESUMEN

INTRODUCTION: The N-localizer is generally utilized in a 3-panel or, more rarely, a 4-panel system for computing stereotactic positions. However, a stereotactic frame that incorporates a 2-panel (bipanel) N-localizer system with panels affixed to only the left and right sides of the frame offers several advantages: improved ergonomics to attach the panels, reduced claustrophobia for the patient, mitigation of posterior panel contact with imaging systems, and reduced complexity. A bipanel system that comprises two standard N-localizer panels yields only two three-dimensional (3D) coordinates, which are insufficient to solve for the stereotactic matrix without further information. While additional information to determine the stereotactic positions could include scalar distances from Digital Imaging and Communications in Medicine (DICOM) metadata or 3D regression across the imaging volume, both have risks related to noise and error propagation. Therefore, we sought to develop new stereotactic localizers that comprise only lateral fiducials (bipanel) that leave the front and back regions of the patient accessible but that contain enough information to solve for the stereotactic matrix using each image independently.  Methods: To solve the stereotactic matrix, we assumed the need to compute three or more 3D points from a single image. Several localizer options were studied using Monte Carlo simulations to understand the effect of errors on the computed target location. The simulations included millions of possible combinations for computing the stereotactic matrix in the presence of random errors of 1mm magnitude. The matrix then transformed coordinates for a target that was placed 50mm anterior, 50mm posterior, 50mm lateral, or 50mm anterior and 50mm lateral to the centre of the image. Simulated cross-sectional axial images of the novel localizer systems were created and converted into DICOM images representing computed tomography (CT) images.  Results: Three novel models include the M-localizer, F-localizer, and Z-localizer. For each of these localizer systems, optimized results were obtained using an overdetermined system of equations made possible by more than three diagonal bars. In each case, the diagonal bar position was computed using standard N-localizer mathematics. Additionally, the M-localizer allowed adding a computation using the Sturm-Pastyr method. Monte Carlo simulation demonstrated that the Z-localizer provided optimal results. CONCLUSION: The three proposed novel models meet our design objectives. Of the three, the Z-localizer produced the least propagation of error. The M-localizer was simpler and had slightly more error than the Z-localizer. The F-localizer produced more error than either the Z-localizer or M-localizer. Further study is needed to determine optimizations using these novel models.

10.
Cureus ; 13(7): e16535, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34327109

RESUMEN

Image-guidance for frame-based stereotaxis is facilitated by incorporating three to four N-localizers or Sturm-Pastyr localizers into a stereotactic frame. An extant frame that incorporates only two N-localizers violates the fundamental principle of the N-localizer, which requires three non-colinear points to define a plane in three-dimensional space. Hence, this two N-localizer configuration is susceptible to error. The present article proposes the V-localizer that comprises multiple diagonal bars to provide four or more non-colinear points to minimize error.

11.
Acta Neurochir (Wien) ; 163(12): 3447-3453, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33983468

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI)-guided laser interstitial thermal therapy (MRIgLITT) was demonstrated to be a viable neurosurgical tool. Apart from its variety of indications, different operative and technical nuances exist. In the present report, for the first time, the use and ability of a traditional Riechert-Mundinger (RM) stereotactic system combined with a novel drill guide kit for MRIgLITT are described. METHODS: A stereotactic frame-based setting was developed by combining an RM system with a drill guide kit and centering bone anchor screwing aid for application together with an MRIgLITT neuro-accessory kit and cooled laser applicator system. The apparatus was used for stereotactic biopsy and consecutive MRIgLITT with an intraoperative high-field MRI scanner in a brain tumor case. RESULTS: The feasibility of an RM stereotactic apparatus and a drill guide kit for MRIgLITT was successfully assessed. Both stereotactic biopsy and subsequent MRIgLITT in a neurooncological patient could easily and safely be performed. No technical problems or complications were observed. CONCLUSION: The combination of a traditional RM stereotactic system, a new drill guide tool, and intraoperative high-field MRI provides neurosurgeons with the opportunity to reliably confirm the diagnosis by frame-based biopsy and allows for stable and accurate real-time MRIgLITT.


Asunto(s)
Neoplasias Encefálicas , Terapia por Láser , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Humanos , Imagenología Tridimensional , Rayos Láser , Imagen por Resonancia Magnética , Técnicas Estereotáxicas
12.
Cureus ; 13(2): e13393, 2021 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-33758694

RESUMEN

INTRODUCTION:  Frame-based stereotaxis has been widely utilized for precise neurosurgical procedures throughout the world for nearly 40 years. The N-localizer is an integral component of most of the extant systems. Analysis of targeting errors related to the N-localizer has not been carried out in sufficient detail. We highlight these potential errors and develop methods to reduce them.  Methods: N-localizer systems comprising three and four N-localizers of various geometries were analyzed using Monte Carlo (MC) simulations. The simulations included native and altered geometric dimensions (Width [W] x Height [H]). Errors were computed using the MC simulations that included the x- and y-axes of vertically oriented rods, that altered the W/H ratio, and that added a fourth N-localizer to a three N-localizer system.  Results: The inclusion of an overdetermined system of equations and the geometries of the N-localizer systems had significant effects on target errors. Root Mean Square Errors (RMS-e) computed via millions of MC iterations for each study demonstrated that errors were reduced by (1) inclusion of the x- and y-coordinates of the vertically oriented rods, (2) a greater triangular area enclosed by the diagonal fiducials of the N-localizer system (stereotactic triangle), (3) a larger W/H ratio, and (4) an N-localizer system that comprised four N-localizers. CONCLUSION: Monte Carlo simulations of Root Mean Square error (RMS-e) is a useful technique to understand targeting while using N-localizer systems in stereotactic neurosurgery. The application of vertical rod positions enhances computational accuracy and can be performed on any N-localizer system. Keeping the target point within the stereotactic triangle enclosed by the diagonal rods can also reduce errors. Additional optimizations of N-localizer geometry may also reduce potential targeting errors. Further analysis is needed to confirm these findings which may have clinical importance.

13.
J Med Imaging (Bellingham) ; 8(1): 015003, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33634206

RESUMEN

Purpose: We explain our concept for customization of a guidance instrument, present a prototype, and describe a set of experiments to evaluate its positioning and drilling accuracy. Methods: Our concept is characterized by the use of bone cement, which enables fixation of a specific configuration for each individual surgical template. This well-established medical product was selected to ensure future intraoperative fabrication of the template under sterile conditions. For customization, a manually operated alignment device is proposed that temporary defines the planned trajectory until the bone cement is hardened. Experiments ( n = 10 ) with half-skull phantoms were performed. Analysis of accuracy comprises targeting validations and experiments including drilling in bone substitutes. Results: The resulting mean positioning error was found to be 0.41 ± 0.30 mm at the level of the target point whereas drilling was possible with a mean accuracy of 0.35 ± 0.30 mm . Conclusion: We proposed a cost-effective, easy-to-use approach for accurate instrument guidance that enables template fabrication under sterile conditions. The utilization of bone cement was proven to fulfill the demands of an easy, quick, and prospectively intraoperatively doable customization. We could demonstrate sufficient accuracy for many surgical applications, e.g., in neurosurgery. The system in this early development stage already outperforms conventional stereotactic frames and image-guided surgery systems in terms of targeting accuracy.

15.
Cureus ; 12(6): e8578, 2020 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-32670714

RESUMEN

All stereotactic neurosurgical procedures utilize coordinate systems to allow navigation through the brain to a target. During the surgical planning, indirect and direct targeting determines the planned target point and trajectory. This targeting allows a surgeon to precisely reach points along the trajectory while minimizing risks to critical structures. Oftentimes, once a target point and a trajectory are determined, a frame-based coordinate system is used for the actual procedure. Considerations include the use of various coordinate spaces such as the anatomical ([Formula: see text]), the frame ([Formula: see text]), the head-stage ([Formula: see text]), and an atlas. Therefore, the relationships between these coordinate systems are integral to the planning and implementation of the neurosurgical procedure. Although coordinate transformations are handled in planning via stereotactic software, critical understanding of the mathematics is required as it has implications during surgery. Further, intraoperative applications of these coordinate conversions, such as for surgical navigation from the head-stage, are not readily available in real-time. Herein, we discuss how to navigate these coordinate systems and provide implementations of the techniques with samples.

16.
J Appl Clin Med Phys ; 20(5): 27-36, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30950167

RESUMEN

BACKGROUND: The stereotactic frame represents the mainstay of accuracy for targeting in stereotactic procedures. Any distortion of the frame may induce a significant source of error for the stereotactic coordinates. OBJECTIVE: To analyze the sources of distortion of the Leksell frame G induced by fixation to the patient's head and to evaluate the clinical impact of frame distortion on the accuracy of targeting in stereotactic procedures. METHODS: We analyzed the torques exerted on the fixation screws after frame placement in a series of patients treated stereotactically by an experienced team. We studied the risk for frame bending in an experimental model of stereotactic frame fixation, with increasing torque of fixation screws in a homogeneous and heterogeneous distribution of torques between the four screws. We assessed the impact of expanding dimensions of bending of the Leksell frame both on surgeries utilizing the stereotactic frame, and on radiosurgical procedures with the Gamma Knife. RESULTS: Frames were fixed clinically at a range of torques of 0.147-0.522 Nm (mean = 0.348 Nm). The torques did not vary significantly with time. Heterogeneity between the two opposite pairs of screws is often limited, but can reach 96.3%. Distortion of the frame may occur even at minimal levels of torque. Heterogeneity between the two opposite pairs of screws will significantly raise the amount of frame distortion. We found a direct correlation between measures of the frame distortion and extend of the deviation from the stereotactic target in clinical models of stereotactic procedures. CONCLUSION: Stereotactic frames were subjected to distortion due to the torque used for frame fixation. The risk of distortion increased with the torque used and the heterogeneity between the torques of the fixation screws. Distortion of the frame was a significant source of inaccuracy of targeting for stereotactic procedures in clinical practice.


Asunto(s)
Calibración , Neoplasias/cirugía , Neurocirugia/instrumentación , Fantasmas de Imagen , Radiocirugia/instrumentación , Técnicas Estereotáxicas/instrumentación , Diseño de Equipo , Humanos , Neurocirugia/normas , Radiocirugia/normas
17.
Res Vet Sci ; 124: 79-84, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30856434

RESUMEN

The treatment of intracranial lesions requires a precise diagnosis with subsequent identification of an adequate therapeutic approach. Stereotactic tumor biopsy may be considered the safest neurosurgical procedure in terms of anticipated results and potential surgical complications. The aim of the present paper was to demonstrate a new method of stereotactic biopsy, based on a patient-specific 3D printed platform in dogs. The system was tested on two canine cadavers, a small (Shih Tzu) and a large (Labrador) breed. Imaginary biopsy targets were defined in a superficial (caudate nucleus) and a deep (piriform lobe) position. Based on 3 Tesla MRI, individualized stereotactic platforms were designed using a semi-automatic approach, and manufactured additively using ABS M30. A pre- and intra-operative CT was performed to compare the planned vs. the realized needle position for precision analyses of the procedure. The target points varied with a precision between 0.09 mm and 0.48 mm. Manufacturing time required 480 to 700 min per platform. The presented patient-specific stereotactic system seems a suitable instrument for application in small animal neurosurgery. In particular, the implementation of relevant stereotactic data may help performing the procedure in rapid sequence and with higher precision than currently-used systems. Required adjustments and adaptions to the respective anatomical conditions are omitted and make the procedure reliable and safe.


Asunto(s)
Biopsia/veterinaria , Encéfalo/patología , Impresión Tridimensional , Técnicas Estereotáxicas/veterinaria , Animales , Biopsia/instrumentación , Biopsia/métodos , Cadáver , Perros , Técnicas Estereotáxicas/instrumentación
18.
J Radiosurg SBRT ; 5(4): 315-322, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30538892

RESUMEN

BACKGROUND: Cone beam CT (CBCT) imaging has been integrated into the most recent version of the Leksell Gamma Knife for the primary purpose to facilitate fractionated therapy. CASE DESCRIPTION: This case study presents three patients where the CBCT system of the Gamma Knife Icon discovered potentially clinically significant frame shifts. In each case, patients were imaged with volumetric MR prior to stereotactic frame placement. Immediately following frame placement, diagnostic stereotactic CT imaging was acquired with a stereotactic indicator box attached to the frame. Following treatment planning and immediately before radiosurgery, a CBCT was acquired using the on-board imaging functionality of the Gamma Knife Icon, which provides a registration of the patient's anatomy to stereotactic space independent of that provided by the stereotactic frame/fiducials. Co-registration of the CT and CBCT provides an estimate of the difference between these two estimates of stereotactic coordinates. The vector magnitudes of the differences measured at the center of stereotactic space were 0.93mm, 2.64mm and 2.18 mm for Case 1, Case 2 and Case 3 respectively. CONCLUSIONS: Use of the CBCT functionality of the Gamma Knife Icon to verify the consistency of frame placement can prevent clinically significant targeting errors due to frame slippage or frame adapter mounting errors, and allows any required adjustments to be made without interrupting the overall treatment workflow.

19.
J Neurosci Methods ; 295: 139-143, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-29253576

RESUMEN

BACKGROUND: It is challenging for researchers performing stereotactic procedures to transition from small animals to non-human primate (NHP) experiments. The NHP stereotactic atlas is based on ear-bar zero (EBZ), which is an anatomical reference frame that is not visible during surgery. Most current NHP stereotactic systems require high-cost MRI or CT imaging and complex computer processing to determine the stereotactic coordinates, limiting the procedure to those with significant expertise. NEW METHOD: We have designed a simplified adaptor consisting of a circular arc for coronal tilt, a carrier for electrodes or cannulas, and an anchor to attach the adaptor to a conventional stereotactic frame. Our adaptor allows easy identification of the EBZ with the help of an anchor notch, and provides digital distance sensors without the need for imaging data or computer processing. Our system enables the use of trajectories that avoid injury to important structures and vessels. RESULTS: We tested the accuracy of our system using simulated targeting with phantoms, and demonstrated sub-millimeter accuracy. Infusion of methylene blue also showed satisfactory staining in target structures deep in the brain. COMPARISON WITH EXISTING METHODS: This system does not require high-cost imaging and extra training to determine EBZ. Once EBZ is set automatically by the system itself, targeting is similar to that in small animal stereotactic procedure. CONCLUSION: Our simple adaptor will aid researchers who plan to conduct experiments involving stereotactic surgery in NHPs.


Asunto(s)
Primates , Técnicas Estereotáxicas/instrumentación , Animales , Encéfalo/patología , Encéfalo/cirugía , Modelos Animales de Enfermedad , Diseño de Equipo , Macaca fascicularis , Fantasmas de Imagen , Accidente Cerebrovascular/patología , Investigación Biomédica Traslacional/instrumentación
20.
Br J Neurosurg ; 32(2): 210-213, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29069919

RESUMEN

OBJECTIVE: Biospies of brain lesions with unknown entity are an everyday procedure among many neurosurgical departments. Biopsies can be performed frame-guided or frameless. However, cerebellar lesions are a special entity with a more complex approach. All biopsies in this study were performed stereotactically frame guided. Therefore, only biopsies of cerebellar lesions were included in this study. We compared whether the frame was attached straight versus oblique and we focused on diagnostic yield and complication rate. METHODS: We evaluated 20 patients who underwent the procedure between 2009 and 2017. Median age was 56.5 years. 12 (60%) Patients showed a left sided lesion, 6 (30%) showed a lesion in the right cerebellum and 2 (10%) patients showed a midline lesion. RESULTS: The stereotactic frame was mounted oblique in 12 (60%) patients and straight in 8 (40%) patients. Postoperative CT scan showed small, clinically silent blood collection in two (10%) of the patients, one (5%) patient showed haemorrhage, which caused a hydrocephalus. He received an external ventricular drain. In both patients with small haemorrhage the frame was positioned straight, while in the patient who showed a larger haemorrhage the frame was mounted oblique. In all patients a final histopathological diagnosis was established. CONCLUSION: Cerebellar lesions of unknown entity can be accessed transcerebellar either with the stereotactic frame mounted straight or oblique. Also for cerebellar lesions the procedure shows a high diagnostic yield with a low rate of severe complications, which need further treatment.


Asunto(s)
Biopsia/métodos , Enfermedades Cerebelosas/patología , Cerebelo/patología , Posicionamiento del Paciente/métodos , Técnicas Estereotáxicas , Adolescente , Adulto , Anciano , Biopsia/efectos adversos , Enfermedades Cerebelosas/diagnóstico por imagen , Neoplasias Cerebelosas/diagnóstico por imagen , Neoplasias Cerebelosas/patología , Neoplasias Cerebelosas/terapia , Cerebelo/diagnóstico por imagen , Femenino , Humanos , Hemorragias Intracraneales/diagnóstico por imagen , Hemorragias Intracraneales/cirugía , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Estudios Retrospectivos , Técnicas Estereotáxicas/efectos adversos , Tomografía Computarizada por Rayos X