Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 312
Filtrar
1.
J Environ Manage ; 370: 122548, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39299115

RESUMEN

High-salt textile dyeing wastewater is difficult to treat. Magnetic fields can enhance the biodegradation capacity and extreme environmental adaptabilities of microorganisms. Thus, magnetically enhanced bioreactors are expected to improve the treatment efficiency and stability of high-salt textile dyeing wastewater. Accordingly, a novel Built-in Static Magnetic Field - Biological Aerated Filter (BSMF-BAF) was constructed and investigated for treating actual high-salt textile dyeing wastewater in this study. Two other BAFs packed with traditional and magnetic ceramsite carriers, respectively, were simultaneously operated for comparison. The removal of color, chemical oxygen demand (COD), suspended solid (SS) and acute toxicity were monitored. The activities of key enzymes and microbial community structure were analyzed to reveal possible mechanisms for improving the treatment efficiency of traditional BAF using the BSMF. The results showed that the BSMF-BAF possessed the highest removal efficiencies of color, COD, SS and acute toxicity among the three BAFs. The BSMF induced significant increases in the activities of azoreductase and lignin peroxidase, which were responsible for the degradation of azo compounds in the wastewater and the detoxification of toxic intermediates, respectively. Additionally, the BSMF induced the relative enrichment of potentially effective bacteria and fungi, and it maintained a relatively high abundance of fungi in the microbial community, resulting in a high treatment efficiency.

2.
Food Res Int ; 195: 114884, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39277269

RESUMEN

In order to explore the application prospects of static magnetic field (SMF) combined with supercooling in meat preservation, this study proposed a novel method of supercooling assisted by a stationary magnetic field (SMF + supercooling) for the preservation of chilled pork, evaluating its cooling rate and quality changes (e.g., water holding capacity, color, pH, and TVB-N), as well as the evolution trend of the microbiota. The results showed that SMF + supercooling significantly (P < 0.05) improved the cooling rate of pork. Compared to chilling and supercooling, SMF + supercooling significantly delayed the increase of TVB-N and TVC on the 12th day of storage (P < 0.05). SMF + supercooling treatment achieves the maintenance of pork water-holding capacity by inhibiting water migration, reducing drip loss, cooking loss, and centrifugal loss of pork. The 16S rDNA bacteria flora analysis demonstrated that SMF + supercooling treatment reduced the relative abundance of spoilage bacteria such as Acinetobacter, Streptococcus, and Pseudomonas, delaying the deterioration of pork quality caused by microbial growth. The SMF + supercooling treatment can be considered a novel refrigeration preservation method that delays the deterioration of pork quality and extends its shelf life.


Asunto(s)
Frío , Almacenamiento de Alimentos , Campos Magnéticos , Animales , Porcinos , Almacenamiento de Alimentos/métodos , Conservación de Alimentos/métodos , Microbiología de Alimentos , Microbiota , Carne de Cerdo/microbiología , Carne de Cerdo/análisis , Bacterias/crecimiento & desarrollo , Bacterias/clasificación , Calidad de los Alimentos , Refrigeración , Concentración de Iones de Hidrógeno , Agua
3.
Eur Radiol ; 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39136707

RESUMEN

OBJECTIVES: The use of magnetic resonance imaging (MRI) is safe from a long-term perspective since there are no known cumulative risks for patients or personnel. However, the technique comes with several acute risks associated with the powerful electromagnetic fields that are necessary to produce medical images. These risks include, among other things, a projectile hazard, loud noise, and the risk of heating. Safe use of MRI requires knowledge about the different hazards related to MRI and organizational structured work including the implementation of routines describing a safe workflow from the referral of a patient to the signed report. In this article, the risks associated with MRI are described along with suggestions for how each risk can be minimized or eliminated. CONCLUSION: The aim of this article is to provide support for the development of, and compliance with, MRI safety routines, and to work with the technique in a safe way. The scope of this treatise does not cover specific details of implant safety, however, the physical principles described can be applied to the risk assessment of implants. KEY POINTS: Establish whether any MR contraindications apply to the patient. Evaluate means to deal with identified risks for both patients and personnel. It is imperative to always perform and document a risk-benefit assessment.

4.
Med Phys ; 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39167028

RESUMEN

Measurement of static magnetic field (B0) homogeneity is an essential component of routine MRI system evaluation. This report summarizes the work of AAPM Task Group (TG) 325 on vendor-specific methods of B0 homogeneity measurement and evaluation. TG 325 was charged with producing a set of detailed, step-by-step instructions to implement B0 homogeneity measurement methods discussed in the American College of Radiology (ACR) MRI Quality Control Manual using specific makes and models of MRI scanners. The TG produced such instructions for as many approaches as was relevant and practical on six currently available vendor platforms including details of software/tools, settings, phantoms, and other experimental details needed for a reproducible protocol. Because edits to these instructions may need to be made as vendors enter and exit the market and change available tools, interfaces, and access levels over time, the step-by-step instructions are published as a living document on the AAPM website. This summary document provides an introduction to B0 homogeneity testing in MRI and several of the common methods for its measurement and evaluation. A living document on the AAPM website provides vendor-specific step-by-step instructions for performing these tests to facilitate accurate and reproducible B0 homogeneity evaluation on a routine basis.

5.
Bioengineering (Basel) ; 11(8)2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39199708

RESUMEN

In contrast to electromagnetic fields, static magnetic fields (SMFs) have not been extensively studied in terms of their potential health consequences. Although upward- and downward-oriented magnetic poles may cause various biological effects, only the pole with the upward orientation has been mainly investigated. Considering that the interaction of antigen-presenting cells (APCs) and T lymphocytes is crucial to trigger an immune response, we assessed the effect of long-term exposure of human T lymphocytes and dendritic cells (DCs) to moderate strength SMFs of different orientations focusing on the cytokine profile of activated T cells. Cultures of allogenic T lymphocytes and DCs (immature and matured by TLR3 and TLR7 agonists) were continuously exposed to four SMFs. The intensity of the applied field was 1 militesla (mT) or 56 mT of the upward- and downward-oriented pole of the SMF. Cell culture supernatants were assayed for IFN-γ, IL-4, IL-17, TNF-α, TNF-ß, IL-1 ß, IL-6, IL-8, and IL-10 by ELISA or flow cytometry. The upward-oriented 56 mT SMF significantly increased the release of IFN-γ and TNF-ß (both p < 0.05) in the cell culture supernatants of T cells and immature DCs. In contrast, the same cultures exposed to the upward-oriented 1 mT SMF showed significantly elevated levels of IL-17 (p < 0.05). The levels of IL-4, TNF-α, IL-1 ß, IL-6, IL-8, and IL-10 were not affected by the upward-oriented SMF. The downward-oriented 56 mT SMF increased TNF-α release when T cells were stimulated with mature DCs. The production of other cytokines was unchanged by the downward-oriented SMF. These findings demonstrate for the first time different in vitro biological effects of upward- and downward-oriented static magnetic fields on the cytokine production of T cells activated by DCs, helping to better understand SMF effects on the immune system and suggesting that the selective SMF effect on the immune response could have potential therapeutic effects in different immune-mediated disorders.

6.
J Environ Manage ; 366: 121805, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39018859

RESUMEN

Sulfurized nanoscale zero-valent iron supported on biochar (BC-SNZVI) has been successfully synthesized for 2,4,6-trichlorophenol (2,4,6-TCP) removal, while was only effectively under acidic conditions. To obtain highly efficient removal of 2,4,6-TCP within a broader pH range, weak static magnetic fields (WMF) was applied in BC-SNZVI/2,4,6-TCP aqueous systems. Results showed 30 mT WMF supported the most extensive 2,4,6-TCP removal, and 87.4% of 2,4,6-TCP (initial concentration of 30 mg/L) was removed by 0.5 g/L BC-SNZVI at neutral pH (pH = 6.8) within 180 min, which was increased by 54.4% compared to that without WMF. The observed rate constant (Kobs) under 30 mT WMF was 2.1-fold greater than that without WMF. Although three typical anions (NO3- (0.5-10.0 mM), H2PO4- (0.05-0.5 mM), and HCO3- (0.5-5.0 mM)) still inhibited 2,4,6-TCP removal, WMF could efficiently alleviate the inhibitory effects. Moreover, 73.1% of 2,4,6-TCP was successfully removed by BC-SNZVI under WMF in natural water. WMF remarkably boosted the dechlorination of 2,4,6-TCP, increasing the 2,4,6-TCP dechlorination efficiency from 45.2% (in the absence of WMF) to 83.8% (in the presence of WMF) by the end of 300 min. And the complete dechlorination product phenol appeared within 10 min. Force analysis confirmed the magnetic field gradient force (FB) moved paramagnetic Fe2+ at the SNZVI surface along the direction perpendicular to the external applied field, promoting the mass-transfer controlled SNZVI corrosion. Corrosion resistance analysis revealed WMF promoted the electron-transfer controlled SNZVI corrosion by decreasing its self-corrosion potential (Ecorr). With the introduction of sulfur, the magnitude of FB doubled and the Ecorr decreased comparing with NZVI. Our findings provide a facile and viable strategy for treating chlorinated phenols at neutral pH.


Asunto(s)
Carbón Orgánico , Clorofenoles , Hierro , Carbón Orgánico/química , Hierro/química , Clorofenoles/química , Concentración de Iones de Hidrógeno , Contaminantes Químicos del Agua/química , Campos Magnéticos
7.
Cell Biochem Biophys ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39023678

RESUMEN

Magnetic Resonance Imaging (MRI) is an important diagnostic technique that uses powerful magnetic fields to generate detailed images of the human body. The aim of this study is to investigate to how static magnetic fields (SMF) affect the levels of trace elements and biochemical parameters in MRI staff' blood serum. This study examines the impacts of these exposures of 18 participants (9 males and 9 females) aged between 25 and 60.on the levels of trace elements in the blood serum and the biochemical parameters of the MRI staff at Azadi Teaching Hospital in Duhok and Zakho General Hospital-Bidari in Zakho City. Eighteen participants, consisting of nine males and nine females aged between 25 and 60, were selected from these hospitals. The researchers obtained blood samples and conducted analysis to determine the presence of trace elements (sodium, potassium, calcium, chloride) as well as numerous biochemical markers. The results showed that potassium and calcium levels increased with age, and older females had considerable deviations. Chloride levels exhibited a significant increase with age in both males and females. Glucose, creatinine, uric acid, and urea levels showed an increase with age, suggesting the possible damage to kidney function caused by continuous exposure to MRI. Increased levels of liver enzymes (GPT, GOT, ALP) and thyroid-stimulating hormone (TSH) were noticed, particularly in older females, indicating potential liver and thyroid dysfunction. These results highlight the importance of applying strict safety protocols and conducting regular health assessments for MRI personnel to minimize the possible hazards.

8.
J Nanobiotechnology ; 22(1): 457, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39085827

RESUMEN

Intervertebral disc degeneration (IVDD) is characterized by the senescence and declining vitality of nucleus pulposus cells (NPCs), often driven by mitochondrial dysfunction. This study elucidates that mesenchymal stem cells (MSCs) play a crucial role in attenuating NPC senescence by secreting mitochondria-containing microvesicles (mitoMVs). Moreover, it demonstrates that static magnetic fields (SMF) enhance the secretion of mitoMVs by MSCs. By distinguishing mitoMV generation from exosomes, this study shifts focus to understanding the molecular mechanisms of SMF intervention, emphasizing cargo transport and plasma membrane budding processes, with RNA sequencing indicating the potential involvement of the microtubule-based transport protein Kif5b. The study further confirms the interaction between Rab22a and Kif5b, revealing Rab22a's role in sorting mitoMVs into microvesicles (MVs) and potentially mediating subsequent plasma membrane budding. Subsequent construction of a gelatin methacrylate (GelMA) hydrogel delivery system further addresses the challenges of in vivo application and verifies the substantial potential of mitoMVs in delaying IVDD. This research not only sheds light on the molecular intricacies of SMF-enhanced mitoMV secretion but also provides innovative perspectives for future IVDD therapeutic strategies.


Asunto(s)
Micropartículas Derivadas de Células , Degeneración del Disco Intervertebral , Campos Magnéticos , Células Madre Mesenquimatosas , Mitocondrias , Núcleo Pulposo , Células Madre Mesenquimatosas/metabolismo , Degeneración del Disco Intervertebral/terapia , Degeneración del Disco Intervertebral/metabolismo , Mitocondrias/metabolismo , Animales , Micropartículas Derivadas de Células/metabolismo , Núcleo Pulposo/metabolismo , Humanos , Ratas , Cinesinas/metabolismo , Células Cultivadas , Ratas Sprague-Dawley , Proteínas de Unión al GTP rab/metabolismo , Masculino
9.
Neuroscience ; 554: 128-136, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39019392

RESUMEN

Aftereffects of non-invasive brain stimulation techniques may be brain state-dependent. Either continuous theta-burst stimulation (cTBS) as transcranial static magnetic field stimulation (tSMS) reduce cortical excitability. Our objective was to explore the aftereffects of tSMS on a M1 previously stimulated with cTBS. The interaction effect of two inhibitory protocols on cortical excitability was tested on healthy volunteers (n = 20), in two different sessions. A first application cTBS was followed by real-tSMS in one session, or sham-tSMS in the other session. When intracortical inhibition was tested with paired-pulse transcranial magnetic stimulation, LICI (ie., long intracortical inhibition) increased, although the unconditioned motor-evoked potential (MEP) remained stable. These effects were observed in the whole sample of participants regardless of the type of static magnetic field stimulation (real or sham) applied after cTBS. Subsequently, we defined a group of good-responders to cTBS (n = 9) on whom the unconditioned MEP amplitude reduced after cTBS and found that application of real-tSMS (subsequent to cTBS) increased the unconditioned MEP. This MEP increase was not found when sham-tSMS followed cTBS. The interaction of tSMS with cTBS seems not to take place at inhibitory cortical interneurons tested by LICI, since LICI was not differently affected after real and sham tSMS. Our results indicate the existence of a process of homeostatic plasticity when tSMS is applied after cTBS. This work suggests that tSMS aftereffects arise at the synaptic level and supports further investigation into tSMS as a useful tool to restore pathological conditions with altered cortical excitability.


Asunto(s)
Potenciales Evocados Motores , Corteza Motora , Plasticidad Neuronal , Estimulación Magnética Transcraneal , Humanos , Estimulación Magnética Transcraneal/métodos , Masculino , Femenino , Adulto , Potenciales Evocados Motores/fisiología , Plasticidad Neuronal/fisiología , Adulto Joven , Corteza Motora/fisiología , Homeostasis/fisiología , Inhibición Neural/fisiología , Ritmo Teta/fisiología
10.
Eur Radiol ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38844619

RESUMEN

OBJECTIVES: Despite some existing studies on the safety of high static magnetic fields (SMFs), the effects of ultra-high SMFs above 20.0 T for embryonic development in early pregnancy are absent. The objective of this study is to evaluate the influence of 16.8-22.0 T SMF on the development of zebrafish embryos, which will provide important information for the future application of ultra-high field magnetic resonance imaging (MRI). METHODS: Two-hour exposure to homogenous (0 T/m) 22.0 T SMF, or 16.8 T SMFs with 123.25 T/m spatial gradient of opposite magnetic force directions was examined in the embryonic development of 200 zebrafish. Their body length, heart rate, spontaneous tail-wagging movement, hatching and survival rate, photomotor response, and visual motor response (VMR) were analyzed. RESULTS: Our results show that these ultra-high SMFs did not significantly affect the general development of zebrafish embryos, such as the body length or spontaneous tail-wagging movement. However, the hatching rate was reduced by the gradient SMFs (p < 0.05), but not the homogenous 22.0 T SMF. Moreover, although the zebrafish larva activities were differentially affected by these ultra-high SMFs (p < 0.05), the expression of several visual and neurodevelopmental genes (p < 0.05) was generally downregulated in the eyeball. CONCLUSIONS: Our findings suggest that exposure to ultra-high SMFs, especially the gradient SMFs, may have adverse effects on embryonic development, which should cause some attention to the future application of ultra-high field MRIs. CLINICAL RELEVANCE STATEMENT: As technology advances, it is conceivable that very strong magnetic fields may be adapted for use in medical imaging. Possible dangers associated with these higher Tesla fields need to be considered and evaluated prior to human use. KEY POINTS: Ultra-High static magnetic field may affect early embryonic development. High strength gradient static magnetic field exposure impacted zebrafish embryonic development. The application of very strong magnetic fields for MR technologies needs to be carefully evaluated.

11.
Front Plant Sci ; 15: 1390031, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38863539

RESUMEN

Static magnetic field (SMF) plays important roles in various biological processes of many organisms including plants, though the molecular mechanism remains largely unclear. Here in this study, we evaluated different magnetic setups to test their effects on growth and development on Arabidopsis (Arabidopsis thaliana), and discovered that plant growth was significantly enhanced by inhomogeneous SMF generated by a regular triangular prism magnet perpendicular to the direction of gravity. Comparative transcriptomic analysis revealed that auxin synthesis and signal transduction genes were upregulated by SMF exposure. SMF also facilitated plants to maintain the iron homeostasis. The expression of iron metabolism-related genes was downregulated by SMF, however, the iron content in plant tissues remains relatively unchanged. Furthermore, SMF exposure also helped the plants to reduce ROS level and synergistically maintain the oxidant balance by enhanced activity of antioxidant enzymes and accumulation of nicotinamide. Taken together, our data suggested that SMF is involved in regulating the growth and development of Arabidopsis thaliana through maintaining iron homeostasis and balancing oxidative stress, which could be beneficial for plant survival and growth. The work presented here would extend our understanding of the mechanism and the regulatory network of how magnetic field affects the plant growth, which would provide insights into the development of novel plant synthetic biology technologies to engineer stress-resistant and high-yielding crops.

12.
Adv Med Sci ; 69(2): 281-288, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38844059

RESUMEN

PURPOSE: Static magnetic fields (SMFs) induce various biological reactions and have been applied in the biological therapy of diseases, especially in combination with mesenchymal stem cells (MSCs) and tissue engineering. However, the underlying influence of SMFs on MSCs gene expression remains largely unclear. In this study, we aim to investigate the effects of SMFs on gene expression of human MSCs. MATERIALS AND METHODS: We exposed human MSCs to two different intensities (0.35 â€‹T and 1.0 â€‹T) of SMFs and observed the effects of SMFs on cell morphology. Subsequently, RNA-sequencing was performed to explore the gene expression changes. RESULTS: Compared with control group cells, no significant differences in cell morphology were observed under a phase contrast inverted microscope, but the transcriptome of SMF-exposed MSCs were significantly changed in both 0.35 â€‹T and 1.0 â€‹T groups and the differential expressed genes are involved in multiple pathways, such as ubiquitin mediated proteolysis, TNF signaling pathway, NF-kappa B signaling pathway, TGF-beta signaling pathway, metabolic pathways, and apoptosis, which regulate the biological functions of MSCs. CONCLUSIONS: SMFs stimulation could affect the gene expression of human MSCs and the biological effects vary by the different intensities of SMFs. These data offer the molecular foundation for future application of SMFs in stem cell technology as well as tissue engineering medicine.

13.
Biomed Phys Eng Express ; 10(4)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38701767

RESUMEN

Thermoluminescent dosimeters (TLDs) serve as compact and user-friendly tools for various applications, including personal radiation dosimetry and radiation therapy. This study explores the potential of utilizing TLD-100 personal dosimetry, conventionally applied in PET/CT (positron emission tomography/computed tomography) settings, in the PET/MRI (magnetic resonance imaging) environment. The integration of MRI into conventional radiotherapy and PET systems necessitates ionizing radiation dosimetry in the presence of static magnetic fields. In this study, TLD-100 dosimeters were exposed on the surface of a water-filled cylindrical phantom containing PET-radioisotope and positioned on the patient table of a 3 T PET/MRI, where the magnetic field strength is around 0.2 T, aiming to replicate real-world scenarios experienced by personnel in PET/MRI environments. Results indicate that the modified MR-safe TLD-100 personal dosimeters exhibit no significant impact from the static magnetic field of the 3 T PET/MRI, supporting their suitability for personal dosimetry in PET/MRI settings. This study addresses a notable gap in existing literature on the effect of MRI static magnetic field on TLDs.


Asunto(s)
Imagen por Resonancia Magnética , Exposición Profesional , Fantasmas de Imagen , Dosimetría Termoluminiscente , Dosimetría Termoluminiscente/métodos , Humanos , Imagen por Resonancia Magnética/métodos , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Dosis de Radiación , Tomografía de Emisión de Positrones/métodos , Monitoreo de Radiación/métodos , Campos Magnéticos , Dosímetros de Radiación
14.
BMC Oral Health ; 24(1): 424, 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38582881

RESUMEN

INTRODUCTION: Neodymium-iron-boron magnets have been suggested as a contemporary method for accelerating the process of orthodontic tooth movement (OTM). A limited number of clinical trials evaluated their effectiveness in accelerating OTM which is desirable for both orthodontists and patients. The present study aimed to investigate the effectiveness of a low-intensity static magnetic field (SMF) in accelerating upper canine retraction movement. MATERIALS AND METHODS: Seventeen patients (mean age 20.76 ± 2.9 years) with their orthodontic treatment decision to extract the upper and lower first premolars due to bimaxillary protrusion malocclusion were included in this split-mouth study. Canine retraction was performed using Nickel-titanium (Ni-Ti) closed-coil springs (150 g of force on each side). The experimental side received SMF via an auxiliary wire that carried 4-neodymium iron-born magnets with an air gap of 2 mm between the magnets to produce a magnetic field density of 414 mT in the region corresponding to the lateral ligament of the upper canine. To determine the rate of upper canine retraction and upper molar drift, alginate impressions were taken once a month to create plaster casts, which were analyzed digitally via a three-dimensional method. RESULTS: The rate of upper canine retraction was significantly greater (P < 0.05) on the SMF side than that on the control side during the first and second months, with an overall duration (19.16%) that was greater than that on the control side. The peak acceleration occurred during the second month (38.09%). No significant differences in upper molar drift were detected between the experimental and control sides (P > 0.05). CONCLUSION: A low-intensity static magnetic field was effective at accelerating upper canine retraction. The difference between the two sides was statistically significant but may not be clinically significant. The SMF did not affect upper molar drift during the upper canine retraction phase. TRIAL REGISTRATION: The trial was retrospectively registered at the ISRCTN registry ( ISRCTN59092624 ) (31/05/2022).


Asunto(s)
Maloclusión , Neodimio , Humanos , Adolescente , Adulto Joven , Adulto , Alambres para Ortodoncia , Boca , Técnicas de Movimiento Dental/métodos , Hierro , Diente Canino
15.
Foods ; 13(8)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38672878

RESUMEN

Fresh pork tenderloin was stored at -3 °C under different static magnetic fields (SMF) of 0, 4, and 10 mT (control, MF-4, and MF-10) to investigate their physicochemical properties changes during storage of 8 days. The initial equilibrium temperature of the samples stored with 4 mT MF was found to be -2.3 °C, which was slightly lower (0.3 °C) than that the control value. The super-chilling phenomenon on the pork was then observed, as the samples stored under the magnetic field did not freeze throughout storage period, but the control experienced a sudden change in temperature after 138 h and then froze. The preservation effect of MF-4 on meat quality was the best in all treatment groups. MF-4 achieved a higher water-retention rate, with drip and cook losses of 6.5% and 29.0% lower than the control, respectively. Meanwhile, the MF-4 effectively delayed the color change in the meat during the storage and the texture hardening after cooking, and effectively controlled the growth of the total volatile saline nitrogen content on the samples. In addition, MF-4 delayed the reduction in myofibrillar protein solubility, sulfhydryl content, and emulsification capacity, indicating that this field inhibited the denaturation of myofibrillar protein. This study can be considered as an application reference of magnetic fields during meat storage at a super-chilled temperature.

16.
Pharmaceuticals (Basel) ; 17(4)2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38675392

RESUMEN

BACKGROUND: Melanoma malignant is characterized by a high mortality rate, accounting for as much as 65% of deaths caused by skin cancer. A potential strategy in cancer treatment may be the use of natural compounds, which include hinokitiol (ß-Thujaplicin), a phenolic component of essential oils extracted from cypress trees. Many studies confirm that a high-induction SMF (static magnetic field) has anticancer effects and can be used as a non-invasive anticancer therapy in combination with or without drugs. AIM: The aim of this experiment was to evaluate the effect of a static magnetic field on melanoma cell cultures (C32 and COLO 829) treated with hinokitiol. METHODS AND RESULTS: Melanoma cells were exposed to a static magnetic field of moderate induction and hinokitiol. The research included determining the activity of the antioxidant enzymes (SOD, GPx, and CAT) and MDA concentration as well as the gene expression profile. CONCLUSION: Hinokitiol disturbs the redox homeostasis of C32 and COLO 829 melanoma malignant cells. Moreover, a static magnetic field has a protective effect on melanoma malignant cells and abolishes the anticancer effect of hinokitiol.

17.
Methods Mol Biol ; 2788: 375-395, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656526

RESUMEN

Geomagnetic field (GMF) protects living organisms on the Earth from the radiation coming from space along with other environmental factors during evolution, and it has affected the growth and development of plants. Many researchers have always been interested in investigating these effects in different aspects. In this chapter, we focus on the methods of using different types of magnetic fields (MFs) to investigate the dimensions of their biological effects on plants. The aim is to increase seed germination, growth characters, and yield of plants using the following methods: (1) Using MFs lower than GMF to study effects of GMF on the growth and yield of plants. (2) Using reversed magnetic fields (RMFs) lower than GMF to study its effects on the growth and development of plants during evolution. (3) Using static magnetic fields (SMFs) higher than GMF and reversed SMFs to study effects of the south (S) and north (N) magnetic pole on plants. (4) Using electromagnetic fields (EMFs) to increase and accelerate seed germination, growth, and yield of plants, and establish the status of plants against other environmental stresses. (5) Using magnetized water (MW) to improve plant seed germination, growth, and yield. (6) Using high gradient magnetic field (HGMF) to study magneto-tropism in plants. In this chapter, we recommend application of various types of MFs to study their biological effects on plants to improve crop production.


Asunto(s)
Germinación , Campos Magnéticos , Desarrollo de la Planta , Semillas , Germinación/efectos de la radiación , Semillas/crecimiento & desarrollo , Semillas/efectos de la radiación , Desarrollo de la Planta/efectos de la radiación , Plantas/efectos de la radiación , Plantas/metabolismo
18.
Sci Rep ; 14(1): 9851, 2024 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684732

RESUMEN

Static magnetic field (SMF) promoting bone tissue remodeling is a potential non-invasive therapy technique to accelerate orthodontic tooth movement (OTM). The periodontal ligament stem cells (PDLSCs), which are mechanosensitive cells, are essential for force-induced bone remodeling and OTM. However, whether and how the PDLSCs influence the process of inflammatory bone remodeling under mechanical force stimuli in the presence of SMFs remains unclear. In this study, we found that local SMF stimulation significantly enhanced the OTM distance and induced osteoclastogenesis on the compression side of a rat model of OTM. Further experiments with macrophages cultured with supernatants from force-loaded PDLSCs exposed to an SMF showed enhanced osteoclast formation. RNA-seq analysis showed that interleukin-6 (IL-6) was elevated in force-loaded PDLSCs exposed to SMFs. IL-6 expression was also elevated on the pressure side of a rat OTM model with an SMF. The OTM distance induced by an SMF was significantly decreased after injection of the IL-6 inhibitor tocilizumab. These results imply that SMF promotes osteoclastogenesis by inducing force-loaded PDLSCs to secrete the inflammatory cytokine IL-6, which accelerates OTM. This will help to reveal the mechanism of SMF accelerates tooth movement and should be evaluated for application in periodontitis patients.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Interleucina-6 , Campos Magnéticos , Osteogénesis , Ligamento Periodontal , Células Madre , Técnicas de Movimiento Dental , Ligamento Periodontal/metabolismo , Ligamento Periodontal/citología , Animales , Interleucina-6/metabolismo , Células Madre/metabolismo , Células Madre/citología , Ratas , Humanos , Osteoclastos/metabolismo , Masculino , Ratas Sprague-Dawley , Células Cultivadas , Remodelación Ósea
19.
Biopreserv Biobank ; 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38527284

RESUMEN

The ability to cryopreserve oocytes without ultrastructural injury has been a concern in the development and use of methods to preserve female reproduction. The stability of the cell membrane must be preserved to reduce the damage caused by ice crystals during vitrification. One approach that has been explored is the use of static magnetic fields (SMFs), which are believed to influence cell membrane stability. In this study, the in vitro effects of SMF that range between 20-80 mT on the vitrification of mice germinal vesicle (GV) oocytes were studied. The viability and mitochondrial (Mt) membrane potential of both vitrified and nonvitrified oocytes were assessed using Trypan blue and JC1 staining. The high in vitro maturation (IVM) rate and high Mt membrane potential in metaphase II (MII) oocytes were taken into account to determine the optimal magnetic field intensity, that is, 20 mT. None of the SMF conditions resulted in intact spindles in MII oocytes. The study also explored the expression of store-operated calcium entry (Stim1, Orai1, and Ip3r) and meiosis resumption (Ccnb, Cdk) genes in GV and MII oocytes of both vitrified and control groups. The results show that the expressions of Orai1 and Ccnb genes in Vit-MII-SMF oocytes were considerably increased. However, no significant difference in Stim1 expression was observed between the groups. The Vit-MII-SMF group exhibited a significantly higher Ccnb expression compared to other groups. In vitro fertilization (IVF) was performed to evaluate the 2 pronuclear (2PN) rates. The findings demonstrated that using 20 mT SMF improved 2PN rates compared to the nonvitrified groups. This study provides a deeper understanding of the effects of moderate SMF and vitrification on the expression of calcium channel genes in GV and MII oocytes. The results suggest that applying a 20 mT SMF can help prevent cryoinjury and enhance the characteristics of vitrified-warmed oocytes.

20.
Sci Rep ; 14(1): 5792, 2024 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-38461218

RESUMEN

Cisplatin is a chemotherapy drug widely used in cancer treatment. Alongside its clinical benefits, however, it may inflict intolerable toxicity and other adverse effects on healthy tissues. Due to the limitation of administering a high dose of cisplatin as well as cancer drug resistance, it is necessary to utilize new methods optimizing treatment modalities through both higher therapeutic efficacy and reduced administered doses of radiation and drugs. In this study, sensitive (A2780) and resistant (A2780CP) ovarian carcinoma cells underwent treatment with cisplatin + static magnetic field (SMF). First, the levels of genotoxicity after treatment were evaluated by Comet assay. Then, cell cycle analysis and apoptosis assay were conducted by a flow cytometer. Lastly, the expression levels of genes involved in apoptosis and cellular drug uptake were investigated by PCR. After treating different groups of cells for 24, 48, and 96 h, the co-treatment of SMF and cisplatin as a combination managed to increase the amount of DNA damage in both sensitive and resistant cell lines. A considerable increase in mortality of cells was also observed mostly in the form of apoptosis, which was caused by inhibition of the cell cycle. The combination also increased the expression levels of apoptotic genes, namely P53 and P21; however, it did not have much effect on the expression levels of BCL2. Besides, the levels of CTR1 gene expression increased significantly in the groups receiving the aforementioned combination. Our study suggests that the combination of cisplatin + SMF might have clinical potential which needs further investigations through future studies.


Asunto(s)
Antineoplásicos , Neoplasias Ováricas , Humanos , Femenino , Cisplatino/farmacología , Cisplatino/uso terapéutico , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Neoplasias Ováricas/patología , Línea Celular Tumoral , Resistencia a Antineoplásicos/genética , Apoptosis , Daño del ADN , Campos Magnéticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA