Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
J AOAC Int ; 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39067039

RESUMEN

BACKGROUND: The National Institute of Standards and Technology (NIST) has produced over 40 botanical dietary supplement Standard Reference Materials® (SRMs) and reference materials (RMs) with values assigned for chemical markers and/or active compounds. Although environmental accumulation or inadvertent introduction of toxic elements (arsenic, cadmium, lead, and mercury) is a potential source of exposure in botanical dietary supplement products, the majority of the dietary supplement SRMs/RMs do not have values assigned for the four major toxic elements. OBJECTIVE: To determine As, Cd, Pb, and Hg content in the current inventory of NIST botanical dietary supplement SRMs/RMs. METHODS: Fifteen SRMs/RMs suites of plant part, extract, and finished products [i.e., solid oral dosage form (SODF)] were analyzed for As, Cd, Pb, and Hg using nitric acid microwave-assisted digestion followed by quantification using inductively coupled plasma-mass spectrometry. RESULTS: Results for control samples were in good agreement with certified values indicating that the analyses of 38 individual botanical SRMs/RMs were in control. Characterization of linked plant/extract SRMs/RMs derived from the same source materials demonstrated that while extraction processes can often yield extracts with lower toxic element content for Hg or As, it is also possible for mass fraction levels to remain unchanged or even increase following extraction. CONCLUSION: The results fill significant knowledge gaps in toxic element content ranges for SRMs/RMs where no NIST assigned values existed, in particular for Hg content and for extract and SODF matrices. With comprehensive toxic element content now available, researchers can better select appropriate dietary supplement SRMs/RMs for use as controls in the analysis of dietary supplement ingredients and products. HIGHLIGHTS: Results for As, Cd, Pb, and Hg are reported for 38 dietary supplement SRMs/RMs including 6 suites of plant, extract, and SODF and 9 pairs of plant and extract from the same batch of plant material.

2.
Environ Geochem Health ; 46(3): 85, 2024 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-38367078

RESUMEN

The instantaneous growth of the world population is intensifying the pressure on the agricultural sector. On the other hand, the critical climate changes and increasing load of pollutants in the soil are imposing formidable challenges on agroecosystems, affecting productivity and quality of the crops. Microplastics are among the most prevalent pollutants that have already invaded all terrestrial and aquatic zones. The increasing microplastic concentration in soil critically impacts crop plants growth and yield. The current review elaborates on the behaviors of microplastics in soil and their impact on soil quality and plant growth. The study shows that microplastics alter the soil's biophysical properties, including water-holding capacity, bulk density, aeration, texture, and microbial composition. In addition, microplastics interact with multiple pollutants, such as polyaromatic hydrocarbons and heavy metals, making them more bioavailable to crop plants. The study also provides a detailed insight into the current techniques available for the isolation and identification of soil microplastics, providing solutions to some of the critical challenges faced and highlighting the research gaps. In our study, we have taken a holistic, comprehensive approach by analysing and comparing various interconnected aspects to provide a deeper understanding of all research perspectives on microplastics in agroecosystems.


Asunto(s)
Contaminantes Ambientales , Contaminantes del Suelo , Microplásticos/toxicidad , Suelo , Plásticos , Contaminantes del Suelo/análisis , Contaminantes Ambientales/análisis , Productos Agrícolas , Ecosistema
3.
Talanta ; 265: 124807, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37327661

RESUMEN

Nitrated polycyclic aromatic hydrocarbons (nitro-PAHs) are suspected to be highly carcinogenic and mutagenic compounds that are present in the environment. Gas chromatography combined with mass spectrometry (GC-MS) is the most frequently used technique for trace analysis. The electron ionization techniques that are currently used in MS, however, typically do not result in the formation of a molecular ion, thus making the determination of these compounds more difficult. In this study, we report on the use of a compact highly-repetitive (low-pulse-energy) ultraviolet (UV) femtosecond laser as the ionization source in combination with a miniature time-of-flight mass analyzer and a time-correlated ion counting system. The UV laser pulses emitted at 343, 257, and 206 nm were produced by harmonic generations of a femtosecond Yb laser emitting at 1030 nm and were utilized for single-color multiphoton ionization. A combination of the 343-nm and 257-nm pulses was further employed to achieve two-color two-photon ionization. This technique was found to be more useful for sensitive detection and also resulted in the formation of a molecular ion. A pump-and-probe technique using these pulses was examined in a proof-of-concept study to measure the femtosecond lifetimes of the nitro-PAHs separated by GC, providing additional information for use in the characterization of the analyte. The developed technique was applied in the analysis of an authentic sample, an organic solvent extract from diesel exhaust particulates. The nitro-PAHs contained in a standard reference material (SRM1975) were determined on a two-dimensional GC-MS display, suggesting that this technique would be useful for the practical trace analysis of nitro-PAHs in environmental samples.

4.
J Steroid Biochem Mol Biol ; 231: 106318, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37169270

RESUMEN

Ninety archived human serum samples from the Vitamin D External Quality Assessment Scheme (DEQAS) were analyzed using a reference measurement procedure (RMP) based on isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS) for the determination of 24,25-dihydroxyvitamin D3 [24,25(OH)2D3]. These 24,25(OH)2D3 results, in conjunction with concentration values assigned using RMPs for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3], provide a valuable resource for assessing the accuracy of measurements for 24,25(OH)2D3 and for investigating the relationship between 24,25(OH)2D3 and 25(OH)D3. Results for 24,25(OH)2D3 using the RMP were compared to DEQAS consensus values demonstrating that the consensus values were not sufficient to assess the accuracy of measurements among different laboratories and methods. A multivariable regression analysis approach using historical DEQAS consensus values for various total 25(OH)D assays was used to assess the contribution of 24,25(OH)2D3 concentration on the assay response. The response of several ligand binding assays for total 25(OH)D was shown to be impacted by the presence of 24,25(OH)2D3.


Asunto(s)
Espectrometría de Masas en Tándem , Vitamina D , Humanos , Cromatografía Liquida , Espectrometría de Masas en Tándem/métodos , Vitaminas , Calcifediol , 24,25-Dihidroxivitamina D 3
5.
Anal Bioanal Chem ; 415(16): 3265-3274, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37231301

RESUMEN

The emergence of mass spectrometry (MS)-based methods to quantify proteins for clinical applications has led to the need for accurate and consistent measurements. To meet the clinical needs of MS-based protein results, it is important that the results are traceable to higher-order standards and methods and have defined uncertainty values. Therefore, we outline a comprehensive approach for the estimation of measurement uncertainty of a MS-based procedure for the quantification of a protein biomarker. Using a bottom-up approach, which is the model outlined in the "Guide to the Expression of Uncertainty of Measurement" (GUM), we evaluated the uncertainty components of a MS-based measurement procedure for a protein biomarker in a complex matrix. The cause-and-effect diagram of the procedure is used to identify each uncertainty component, and statistical equations are derived to determine the overall combined uncertainty. Evaluation of the uncertainty components not only enables the calculation of the measurement uncertainty but can also be used to determine if the procedure needs improvement. To demonstrate the use of the bottom-up approach, the overall combined uncertainty is estimated for the National Institute of Standards and Technology (NIST) candidate reference measurement procedure for albumin in human urine. The results of the uncertainty approach are applied to the determination of uncertainty for the certified value for albumin in candidate NIST Standard Reference Material® (SRM) 3666. This study provides a framework for measurement uncertainty estimation of a MS-based protein procedure by identifying the uncertainty components of the procedure to derive the overall combined uncertainty.


Asunto(s)
Albúminas , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Cromatografía Liquida/métodos , Incertidumbre , Estándares de Referencia
7.
Heliyon ; 9(1): e12844, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36691535

RESUMEN

Three microwave-assisted digestion procedures, followed by analysis of digestates employing inductively coupled mass spectrometry (ICP-MS) were evaluated for use in the determination of elements at trace and ultra-trace levels in PM2.5 samples. Digestion procedure 1 used 2.5 mL HNO3 (65%) at 200 °C. Procedure 2, consisted of a two-stage digestion step at 200 °C with 2.5 mL HNO3 (65%) and 3 µL HF (48%) followed by 24 µL H3BO3 (5%). A 10-fold increase in the amounts of HF and H3BO3 was used for procedure 3. The addition of HF/H3BO3 was carried out to aid the dissolution of silicate matrices and refractory compounds. The digestions were carried out using PTFE ultra-trace inserts which increased the sample throughput threefold. The addition of small quantities of HF resulted in the effective solubilisation of Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Sr, Cd, Sb and Pb. The optimal method using HNO3/HF/H3BO3 digestion as in procedure 3 showed recovery efficiency greater than 70% for all elements. The validated method was applied to quantify the elemental content of indoor and outdoor PM2.5 (with samples <0.5 mg) at an urban background site in Malta.

8.
J Mass Spectrom Adv Clin Lab ; 27: 24-32, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36593910

RESUMEN

Background: Steroids play a key role in numerous physiological processes. Steroid determination is a useful tool to explore various endocrine diseases. Because of its specificity, mass spectrometry is considered to be a reference method for the determination of steroids in serum compared to radioimmunoassay. This technology could progress towards more automation for the optimal organization of clinical laboratories and ultimately for the benefit of patients. Methods: A fully automated ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed and fully validated to determine five steroids in serum. Sample preparation was based on protein precipitation with filtration followed by online solid phase extraction. Chromatographic separation was performed using a biphenyl stationary phase. Results: The method was successfully validated according to European Medicine Agency guidelines. Coefficients of variation did not exceed, respectively, 8.4% and 8.1% for intra- and inter-assay precision. Method comparison with radioimmunoassay showed a proportional bias for all compounds, except for testosterone in men. Comparison with another LC-MS/MS method demonstrated acceptable concordance for all steroids, although a small bias was observed for androstenedione. Conclusion: The novelty of this method is that it has been fully automated. Automation provides benefits in traceability and allows significant savings in cost and time.

9.
Environ Int ; 166: 107345, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35717713

RESUMEN

Whole mixture-based testing using in vitro new approach methodologies (NAMs) has been suggested to facilitate the hazard and risk assessment of complex environmental mixtures. Previous studies have shown that phosphorylation of DNA damage signaling proteins checkpoint kinase 1 (pChk1) and histone 2AX (γH2AX) are sensitive markers that can be used for estimating carcinogenicity potencies in vitro. Here, and with the aim to better validate the applicability, in vitro-based Mixture Potency Factors (MPFs) of Standard Reference Materials (SRMs) from environmental polycyclic aromatic hydrocarbon (PAH)-containing mixtures were determined and compared to published mutagenicity and tumorigenicity data. Also, genotoxicity was assessed by a flow cytometry-based micronucleus (MN) assay which showed that only benzo[a]pyrene (B[a]P) and coal tar SRM (SRM1597a) caused dose-dependent increases of MN formation, while extracts of diesel particulate matter (SRM1650b), diesel particulate extract (SRM1975), and urban dust (SRM1649b) did not. However, a dose-dependent activation of DNA damage signaling was observed for all PAHs and SRMs. The results demonstrated that all SRMs were more potent than B[a]P, at B[a]P-equivalent concentrations, to induce pChk1 and γH2AX, and that western blot was more sensitive than the In-Cell Western assay in detecting their activation in response to these complex mixtures. Relative MPFs, based on dose-response modelling of pChk1 and γH2AX, ranged 113 - 5270 for the SRMs, indicating several orders of magnitude higher genotoxic potential than B[a]P. Moreover, these MPFs were in good agreement with potency values based on published data from Salmonella mutagenicity and in vivo carcinogenicity studies. In conclusion, these comparisons further validate the feasibility of applying in vitro NAMs, such as whole-mixture based MPFs, in cancer risk assessment of complex mixtures.

10.
Anal Bioanal Chem ; 414(24): 7015-7022, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35697811

RESUMEN

Certified reference materials (CRMs) are routinely used by analytical chemists to validate new analytical methods and to demonstrate the quality of their quantitative measurements. Even though CRMs for trace element and trace organic analysis have been available and widely used for over 50 years, the majority of papers published in analytical chemistry journals do not mention the use of CRMs. What if analytical/bioanalytical chemistry journals required the use of CRMs to publish a paper? This feature article attempts to address this question by providing examples of recent papers that have made exceptional use of CRMs to validate new analytical methods and to describe novel, alternative uses of CRMs that provide new characterization of the CRM. The potential benefits of using a CRM even when it does not have certified values for the analytes of interest are presented.


Asunto(s)
Publicaciones Periódicas como Asunto , Oligoelementos , Química Analítica , Estándares de Referencia
11.
Biomed Chromatogr ; 36(7): e5378, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35368089

RESUMEN

Vitamin K is an essential micronutrient required for blood coagulation, regulation of vascular calcification and bone mineralization. Plasma and serum measurements of vitamin K1 (phylloquinone, K1 ) made using high-performance liquid chromatography with fluorescence detection, or tandem mass spectrometry are used clinically and in population studies to assess vitamin K status. Standard reference materials provide a validation tool for laboratories, helping assure clinical diagnosis and the comparability of data from different populations. We manufactured two K1 standard reference materials, in 2009 (KEQAS SRM-001) and in 2019 (KEQAS SRM-002). The target concentrations of K1 were assigned to each SRM using the All Laboratory Trimmed Mean of results reported by selected laboratories enrolled in the Vitamin K External Quality Assurance Scheme (KEQAS). The assigned concentrations of K1 for KEQAS SRM-001 and SRM-002 were 0.25 and 0.36 µg/L respectively. In 2019 KEQAS SRM-001 was re-analysed simultaneously with KEQAS SRM-002 to provide traceability between the two standards, therefore aiding comparability of analysis performed using these materials. Both standards were stored as aliquots at -80°C in the dark; annual re-analysis of the materials indicated that K1 is stable for at least 12 years in these conditions.


Asunto(s)
Espectrometría de Masas en Tándem , Vitamina K 1 , Cromatografía Líquida de Alta Presión/métodos , Humanos , Estándares de Referencia , Espectrometría de Masas en Tándem/métodos , Vitamina K , Vitamina K 1/química
12.
Toxicol Rep ; 9: 136-146, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35145877

RESUMEN

BACKGROUND: Amphibian species are being threatened worldwide and chemical pollution is one of the leading causes of this decline. The use of agrochemicals such as organochlorine pesticides (OCPs) among the several health and ecological challenges it causes, the sharp amphibian population decline is most pressing.Toad specimens Amietophrynus regularis were sampled from three (3) selected areas; each comprising of natural habitat and dumpsites within Lagos metropolis. METHODS: The congeners of organochlorine pesticides were tested in the liver, intestine, and parasite (Cosmocerca sp.) of the toads and soil samples from the respective locations using gas chromatography-mass spectrometer (GC-MS). Histopathological analyses were conducted on the intestines and liver of the toads using hematoxylin and eosin (H&E) stain and then examined under the binocular dissecting microscope. RESULTS: The concentration of aldrin in the intestine of A. regularis sampled at the dumpsites was higher than the concentrations in the intestines of A. regularis in the natural habitat. The concentrations of dieldrin in the uninfected A. regularis at both dumpsite and natural habitat were higher than the concentrations in the infected A. regularis at both environments. This indicated that the parasite Cosmocerca sp. may have played a depurative role in sequestering the concentration of dieldrin in the toads irrespective of the location. The parasites exhibited marked sequestration capacity characterized by the notably high total bioaccumulation rate both in the liver and the intestine at the dumpsite. The stunted villi being the common histological alteration in the infected and uninfected toads at the dumpsite but missing in the uninfected counterparts at the natural habitat may be attributed to the differences in the background concentration of the OCP congeners. CONCLUSIONS: The parasite- Cosmocerca sp. has been shown to be a potential tool in the biomonitoring of these OCP congeners which persists in the environment. Continuous research on these congeners is a searchlight to checkmate the environment to see how compliant industries and the consumers are in terms of regulation of these chemicals.

13.
Anal Bioanal Chem ; 414(1): 31-52, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34291299

RESUMEN

During the past 40 years, the National Institute of Standards and Technology (NIST) has developed over 180 natural matrix Standard Reference Materials® (SRMs) for the determination of trace organic constituents in environmental, clinical, food, and dietary supplement matrices. A list of the Top Ten SRMs intended for organic analysis was identified based on selection criteria including analytical challenge to assign certified values, challenges in material preparation, novel matrices, longevity, widespread use, and unique design concept or intended use. The environmental matrix SRMs include air particulate matter, marine sediment, mussel tissue, and human serum with the focus on contaminants such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs). Human serum and plasma SRMs for clinical diagnostic markers including vitamin D metabolites represent clinical analysis, whereas infant formula, multivitamin/multielement tablets, and Ginkgo biloba constitute the food and dietary supplement matrices on the list. Each of the SRMs on the Top Ten list is discussed relative to the selection criteria and significance of the material, and several overall lessons learned are summarized.


Asunto(s)
Polvo/análisis , Sedimentos Geológicos/química , Ginkgo biloba/química , Estándares de Referencia , Suero/química , Humanos , Océanos y Mares , Estados Unidos , United States Government Agencies
14.
Front Med (Lausanne) ; 8: 696367, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34746169

RESUMEN

Iron isotopes are fractionated by multiple biological processes, which offers a novel opportunity to study iron homeostasis. The determination of Fe isotope composition in biological samples necessitates certified biological reference materials with known Fe isotopic signature in order to properly assess external reproducibility and data quality between laboratories. We report the most comprehensive study on the Fe isotopic composition for widely available international biological reference materials. They consist of different terrestrial and marine animal organs (bovine, porcine, tuna, and mussel) as well as apple leaves and human hair (ERC-CE464, NIST1515, ERM-DB001, ERM-BB186, ERM-BB184, ERM-CE196, BCR668, ERM-BB185, ERM-BB124). Previously measured Fe isotopic compositions were available for only two of these reference materials (ERC-CE464 tuna fish and ERM-BB186 pig kidney) and these literature data are in excellent agreement with our data. The Fe isotopic ratios are reported as the permil deviation of the 56Fe/54Fe ratio from the IRMM-014 standard. All reference materials present δ56Fe ranging from -2.27 to -0.35%0. Combined with existing data, our results suggest that animal models could provide useful analogues of the human body regarding the metabolic pathways affecting Fe isotopes, with many potential applications to medicine.

15.
Pract Lab Med ; 25: e00228, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34095414

RESUMEN

OBJECTIVES: In 2009, the Japan Society of Clinical Chemistry (JSCC) recommended a reference method for the measurement of serum high-density lipoprotein cholesterol (HDL-C) and low-density lipoprotein cholesterol (LDL-C) levels. This automated method uses cholesterol esterase-cholesterol dehydrogenase to measure cholesterol levels in fractions obtained after ultracentrifugation and dextran sulfate/magnesium chloride precipitation. In the present study, using fresh samples, we compared the LDL-C and HDL-C levels measured using this method with those measured using the traditional Centers for Disease Control and Prevention (CDC)-beta-quantification (BQ) method. DESIGN: and methods: Using both the JSCC and CDC-BQ methods, LDL-C/HDL-C levels were measured in 47 non-diseased and 126 diseased subjects, whose triglyceride levels were lower than 11.29 â€‹mmol/L (1000 â€‹mg/dL). RESULTS: For LDL-C, the equation of the line representing the correlation between the two methods was y â€‹= â€‹0.991x + 0.009 â€‹mmol/L; r â€‹= â€‹0.999; and Sy/x â€‹= â€‹0.025 â€‹mmol/L, where x is the mean LDL-C level measured using the CDC-BQ method. Similarly, for HDL-C, the equation of the line representing the correlation between the two methods was y â€‹= â€‹0.988x + 0.041 â€‹mmol/L, r â€‹= â€‹0.999, and Sy/x â€‹= â€‹0.019 â€‹mmol/L, where x is the mean HDL-C level measured using the CDC-BQ method. CONCLUSIONS: The JSCC method agreed with the CDC-BQ method in cases of both non-diseased and diseased subjects, including those with dyslipidemia.

16.
Metabolites ; 11(4)2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33808182

RESUMEN

Calibration-Curve-Locking Databases (CCLDs) have been constructed for automatic compound search and semi-quantitative screening by gas chromatography/mass spectrometry (GC/MS) in several fields. CCLD felicitates the semi-quantification of target compounds without calibration curve preparation because it contains the retention time (RT), calibration curves, and electron ionization (EI) mass spectra, which are obtained under stable apparatus conditions. Despite its usefulness, there is no CCLD for metabolomics. Herein, we developed a novel CCLD and semi-quantification framework for GC/MS-based metabolomics. All analytes were subjected to GC/MS after derivatization under stable apparatus conditions using (1) target tuning, (2) RT locking technique, and (3) automatic derivatization and injection by a robotic platform. The RTs and EI mass spectra were obtained from an existing authorized database. A quantifier ion and one or two qualifier ions were selected for each target metabolite. The calibration curves were obtained as plots of the peak area ratio of the target compounds to an internal standard versus the target compound concentration. These data were registered in a database as a novel CCLD. We examined the applicability of CCLD for analyzing human plasma, resulting in time-saving and labor-saving semi-qualitative screening without the need for standard substances.

17.
Clin Chem Lab Med ; 59(4): 671-679, 2021 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-33098630

RESUMEN

OBJECTIVES: Matrix differences among serum samples from non-pregnant and pregnant patients could bias measurements. Standard Reference Material 1949, Frozen Human Prenatal Serum, was developed to provide a quality assurance material for the measurement of hormones and nutritional elements throughout pregnancy. METHODS: Serum from non-pregnant women and women in each trimester were bottled into four levels based on pregnancy status and trimester. Liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were developed and applied to the measurement of thyroid hormones, vitamin D metabolites, and vitamin D-binding protein (VDBP). Copper, selenium, and zinc measurements were conducted by inductively coupled plasma dynamic reaction cell MS. Thyroid stimulating hormone (TSH), thyroglobulin (Tg), and thyroglobulin antibody concentrations were analyzed using immunoassays and LC-MS/MS (Tg only). RESULTS: Certified values for thyroxine and triiodothyronine, reference values for vitamin D metabolites, VDBP, selenium, copper, and zinc, and information values for reverse triiodothyronine, TSH, Tg, and Tg antibodies were assigned. Significant differences in serum concentrations were evident for all analytes across the four levels (p≤0.003). TSH measurements were significantly different (p<0.0001) among research-only immunoassays. Tg concentrations were elevated in research-only immunoassays vs. Federal Drug Administration-approved automated immunoassay and LC-MS/MS. Presence of Tg antibodies increased differences between automated immunoassay and LC-MS/MS. CONCLUSIONS: The analyte concentrations' changes consistent with the literature and the demonstration of matrix interferences in immunoassay Tg measurements indicate the functionality of this material by providing a relevant matrix-matched reference material for the different stages of pregnancy.


Asunto(s)
Selenio , Oligoelementos , Biomarcadores/sangre , Cromatografía Liquida , Cobre , Femenino , Humanos , Embarazo , Espectrometría de Masas en Tándem , Tiroglobulina/sangre , Glándula Tiroides , Tirotropina , Oligoelementos/sangre , Vitamina D/sangre , Vitaminas , Zinc
18.
Mol Cell Probes ; 55: 101690, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33345976

RESUMEN

Several rapid methods based on nucleic acids can detect foodborne pathogens, such as Salmonella spp. However, a common reference that enables metrological traceability among measurement results is not available. Reference materials (RM) are thus key to guarantee methodological comparability. This study developed a candidate genomic DNA reference material for Salmonella enteritidis quantification to establish performance conditions and reference values for normalized RM production. The growth of Salmonella enteritidis ATCC® 13076 in Rappaport Vassiliadis selective medium was characterized, and we optimized a method of DNA extraction using cetrimonium bromide (CTAB) and LiCl. In a first stage six concentrations of DNA were prepared with and without yeast RNA (40 ng/µL) to evaluate its effect as a stabilizer in terms of homogeneity and short-term stability. Based on the findings, in a second stage two DNA concentrations were prepared and a reference value with its uncertainty was assigned based on the results of characterization, homogeneity, and stability studies using digital polymerase chain reaction and the gene targets, invA, ttr, and hilA. The material was stable for 9 months at 4 °C, with a expanded uncertainty contribution range of 11%-14%. The novel candidate RM is the first to be developed nationwide and will improve the quality of measurements in the area of food safety.


Asunto(s)
Genoma Bacteriano , Reacción en Cadena de la Polimerasa/métodos , Salmonella enteritidis/genética , Salmonella enteritidis/aislamiento & purificación , ADN Bacteriano/genética , ADN Bacteriano/aislamiento & purificación , Congelación , Cinética , Estándares de Referencia , Análisis de Regresión , Salmonella enteritidis/crecimiento & desarrollo , Incertidumbre
19.
J Res Natl Inst Stand Technol ; 126: 126044, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-39081639

RESUMEN

Standard Reference Material (SRM) 2806: Medium Test Dust in Hydraulic Fluid represents a series of reference materials certified by the National Institute of Standards and Technology (NIST) used to calibrate liquid-borne optical (or automatic) particle counters applied in a wide range of industrial, aerospace, and military applications. The series, including SRM 2806b, and SRM 2806d, was manufactured for NIST by IFTS, Institut de la Filtration et des Techniques Séparatives International Filter Testing Services, in France. An important factor for the acceptance of the material for certification was the degree of bottle-to-bottle homogeneity, which was evaluated by both IFTS and NIST. A statistical graphics methodology was developed that provided immediate visual as well as quantitative statistical metrics with which to characterize the SRM. This NIST-developed approach was used in four studies to assess the homogeneity of the material during both its production stage and its finished bottled-product stage. IFTS performed measurements using an optical particle counter for on-line quality assurance and sampled 40 bottles of the finished 400 bottle series to determine homogeneity from the particle size distribution. NIST also determined the particle size distribution of the finished material and performed microscopy to look for possible contaminant material in the suspension. An accelerated aging experiment was conducted on both materials (2806b and 2806d) to verify their stability.

20.
Powder Diffr ; 35(1)2020.
Artículo en Inglés | MEDLINE | ID: mdl-33311851

RESUMEN

The National Institute of Standards and Technology (NIST) certifies a suite of Standard Reference Materials (SRMs) to evaluate specific aspects of instrument performance of both X-ray and neutron powder diffractometers. This report describes SRM 660c, the fourth generation of this powder diffraction SRM, which is used primarily for calibrating powder diffractometers with respect to line position and line shape for the determination of the instrument profile function (IPF). It is certified with respect to lattice parameter and consists of approximately 6 g of lanthanum hexaboride (LaB6) powder. So that this SRM would be applicable for the neutron diffraction community, the powder was prepared from an isotopically enriched 11B precursor material. The microstructure of the LaB6 powder was engineered specifically to yield a crystallite size above that where size broadening is typically observed and to minimize the crystallographic defects that lead to strain broadening. A NIST-built diffractometer, incorporating many advanced design features, was used to certify the lattice parameter of the LaB6 powder. Both Type A, statistical, and Type B, systematic, uncertainties have been assigned to yield a certified value for the lattice parameter at 22.5 °C of a = 0.415 682 6 ± 0.000 008 nm (95% confidence).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA