Environ Sci Pollut Res Int ; 31(40): 52804-52814, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39160406

RESUMEN

Volatile organic compounds (VOCs) are continuously emitted into the atmosphere from natural and anthropogenic sources and rapidly spread from the atmosphere to different environments. A large group of VOCs has been included in the class of air pollutants; therefore, their determination and monitoring using reliable and sensitive analytical methods represents a key aspect of health risk assessment. In this work, an untargeted approach is proposed for the evaluation of the exposure to volatile organic compounds of workers in an engine manufacturing plant by GC-MS measurements, coupled with solid-phase microextraction (SPME). The analytical procedure was optimized in terms of SPME fiber, adsorption time, desorption time, and temperature gradient of the chromatographic run. For the microextraction of VOCs, the SPME fibers were exposed to the air in two different zones of the manufacturing factory, i.e., in the mixing painting chamber and the engine painting area. Moreover, the sampling was carried out with the painting system active and running (system on) and with the painting system switched off (system off). Overall, 212 compounds were identified, but only 17 were always present in both zones (mixing painting chamber and engine painting area), regardless of system conditions (on or off). Finally, a semi-quantitative evaluation was performed considering the peak area value of the potentially most toxic compounds by multivariate data analyses.


Asunto(s)
Contaminación del Aire Interior , Monitoreo del Ambiente , Cromatografía de Gases y Espectrometría de Masas , Microextracción en Fase Sólida , Compuestos Orgánicos Volátiles , Compuestos Orgánicos Volátiles/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Contaminantes Atmosféricos/análisis , Humanos , Lugar de Trabajo , Condiciones de Trabajo
2.
Sci Total Environ ; 948: 174610, 2024 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-38997033

RESUMEN

Among the numerous organochlorines (OCs) applied in the French West Indies (FWI), chlordecone (hydrated form C10Cl10O2H2; CLD) still causes major environmental pollution nowadays. A recent report revealed the unexpected presence in FWI environment of transformation products (TPs) of CLD not routinely monitored due to a lack of commercial standards. Here, we present a method for surface waters and groundwaters to analyze CLD, its main TPs (hydroCLDs, chlordecol (CLDOH), 10-monohydroCLDOH and polychloroindenes) and other OCs. We developed an SPME-GC-SIM/MS method with a PDMS-DVB fiber. Since CLDOH-d commonly used as internal standard (IS) proved unsuitable, we synthesized several IS candidates, and finally identified 10-monohydro-5-methyl-chlordecol as a satisfactory IS for CLDOH and 10-monohydroCLDOH avoiding the use of 13C-labelled analogue. LODs for CLD and its TPs varied from 0.3 to 10 ng/L, equal to or below LODs of the two laboratories, BRGM (the French geological survey) and LDA26 (one of the French Departmental Analytical Laboratories), requested in FWI pollution monitoring that used liquid-liquid extractions and advanced facilities (LLE-GC-MS/MS and LLE-LC-MS/MS methods, respectively). Then, we extended the multi-residue method to 30 OCs (CLD and its TPs, mirex, ß-HCH, lindane, dieldrin, aldrin, HCB, hexachlorobutadiene, TCE, PCE) and applied it to 30 surface and ground waters from FWI. While CLD, 8- and 10-monohydroCLD, CLDOH, 10-monohydroCLDOH, dieldrin, and ß-HCH were detected and quantified, pentachloroindene, another CLD TP, was sporadically found in trace levels. A comparison with BRGM and LDA26 confirmed the interest of the SPME method. Results suggested an underestimation of CLDOH and an overestimation of high CLD concentrations with one of the currently used routine protocol. In light of these findings, previous temporal monitoring of environmental waters in FWI were re-examined and revealed some atypical values, which may indeed be due to analytical bias. These discrepancies call for intensified efforts to reliably quantify CLD and its TPs.

3.
Food Chem ; 459: 140276, 2024 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38981380

RESUMEN

The sensitive detection of polychlorinated biphenyls (PCBs) is crucial for protecting the environment and human health. Herein, we constructed a Materials Institute Lavoisier 88B (MIL-88B)-on-University of Oslo 66 (UiO-66) composite (MIL-on-UiO) with a unique nanoflower morphology, in which highly stable UiO-66 is the precursor, with MIL-88B grown on its surface. MIL-on-UiO was used as a fiber coating for headspace solid-phase microextraction to enrich PCBs. Experimental results demonstrated that MIL-on-UiO provided better enrichment performance for PCBs than single components due to multiple interactions, including π-π stacking, halogen bonding, pore-filling, and steric hindrance effects. The method established using the MIL-on-UiO-based SPME fiber coating provided a good linear relationship in the range of 0.001-50 ng·mL-1, with limits of detection ranging from 0.0002 to 0.002 ng·mL-1 and enrichment factors between 3530 and 7420. In addition, the method was used to detect trace PCBs in water and orange juice achieving satisfactory recoveries (81%-111%).


Asunto(s)
Contaminación de Alimentos , Bifenilos Policlorados , Microextracción en Fase Sólida , Bifenilos Policlorados/análisis , Bifenilos Policlorados/química , Microextracción en Fase Sólida/métodos , Contaminación de Alimentos/análisis , Límite de Detección , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/química , Estructuras Metalorgánicas/química , Bebidas/análisis
4.
Int J Cosmet Sci ; 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39054565

RESUMEN

OBJECTIVE: The aim of this study is to develop and optimize a method for evaluating the persistence of residual fragrance after body washing, addressing a significant requirement in the development of personal care products. The main objective is to establish a reliable, sensitive and reproducible analytical technique to assess fragrance longevity on skin post-use of body wash products. METHODS: Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) is used to analyse residual fragrances. We investigate the extraction efficiencies of various SPME fibres and compare different methods for sampling skin-emitted fragrances, including tape stripping and sealed glass funnels. A controlled body-washing procedure is implemented to standardize the cleansing process. RESULTS: Our findings indicate that the relative standard deviation for measuring five distinct fragrances is within the range of 3%-14%, highlighting the precision of the method. A notable variance exists in the extraction efficiency of fragrances using different types of SPME fibres, with some exhibiting over a threefold difference. Furthermore, the glass funnel method for fragrance collection demonstrates an 11.7 times greater sensitivity to galaxolide than that of the tape-stripping method. Residual fragrances with base notes as the main components can be detected on the skin up to 24 h after body washing. CONCLUSION: The optimized method for residual fragrance evaluation developed in this study offers a robust tool for analysing fragrance components persisting on the skin for up to 24 h post-wash. This advancement facilitates a deeper understanding of fragrance longevity in personal care products, enabling comparative analyses between different products.


OBJECTIF: l'objectif de cette étude est de développer et d'optimiser une méthode d'évaluation de la persistance du parfum résiduel après la toilette du corps, répondant à une exigence significative dans le développement de produits de soins personnels. L'objectif principal est d'établir une technique analytique fiable, sensible et reproductible pour évaluer la longévité des parfums sur la peau après utilisation de produits de toilette pour le corps. METHODES: la microextraction en phase solide de l'espace de tête (HS­SPME) couplée à la chromatographie en phase gazeuse­spectrométrie de masse (GC­MS) est utilisée pour analyser les parfums résiduels. Nous étudions l'efficacité de l'extraction de diverses fibres SPME et nous comparons différentes méthodes d'échantillonnage des senteurs émises par la peau, y compris le stripping sur ruban adhésif et les entonnoirs en verre scellés. Une procédure contrôlée de lavage du corps est mise en place pour standardiser le processus de nettoyage. RÉSULTATS: nos résultats indiquent que l'écart­type relatif pour mesurer cinq parfums distincts se situe dans la plage de 3% à 14%, ce qui souligne la précision de la méthode. Une variance notable existe dans l'efficacité d'extraction des parfums utilisant différents types de fibres de SPME, certaines présentant plus d'un triplement de différence. En outre, la méthode de l'entonnoir en verre pour la collecte des parfums démontre une sensibilité au galaxolide 11,7 fois supérieure à celle de la méthode de stripping sur ruban adhésif. Les parfums résiduels avec des notes de fond comme principaux composants peuvent être détectés sur la peau jusqu'à 24 h après le lavage du corps. CONCLUSION: la méthode optimisée pour l'évaluation du parfum résiduel développée dans cette étude offre un outil fiable pour analyser les composants du parfum persistant sur la peau jusqu'à 24 heures après le lavage. Cette avancée offre une meilleure compréhension de la longévité des parfums dans les produits de soins personnels, permettant des analyses comparatives entre les différents produits.

5.
Anal Chim Acta ; 1318: 342954, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39067930

RESUMEN

BACKGROUND: Liver transplantation is the definitive treatment for end-stage liver failure, but the scarcity of donor organs remains a significant challenge. Leveraging organs from extended criteria donors (ECD) offers a potential avenue to address worldwide shortages, though these organs are more susceptible to post-reperfusion injury. This study explores the use of normothermic ex vivo liver perfusion (NEVLP) as a method for organ preservation - an approach that sustains liver metabolism and facilitates pre-transplant assessments of organ viability via bile analysis. The focal point of this study revolves on the development of analytical methods for determining the bile acid profile throughout the peritransplantation period as a potential indicator of liver function and viability. RESULTS: The study optimized and validated a high-throughput analytical method to quantify selected bile acids in bile samples using a thin-film microextraction-liquid chromatography-mass spectrometry (TFME-LC-MS) platform. Furthermore, it introduced a solid-phase microextraction-microfluidic open interface-mass spectrometry (SPME-MOI-MS) method for rapid direct analysis of bile acid isobar groups. In the animal study, discernible variations in the concentrations of specific bile acids were observed between donors after circulatory death (DCD) and heart-beating donors (HBD), particularly following normothermic perfusion and reperfusion. Noteworthy fluctuations in individual bile acid concentrations were observed throughout the entire organ transplantation process, with taurocholic acid (TCA), glycocholic acid (GCA), and glycochenodeoxycholic acid (GCDCA) emerging as promising indicators of organ quality. The efficacy of the SPME-MOI-MS platform in corroborating these trends highlights its potential for real-time bile acid analysis during liver transplantation procedures. SIGNIFICANCE: Our findings underscore the efficacy of NEVLP in tandem with advanced bile acid analysis methods as a reliable strategy for pre-transplant assessments of organ viability, potentially increasing the use of ECD organs and reducing organ shortages. The ability to monitor bile acid profiles in real-time provides crucial insights into liver function and ischemic injury, making significant strides in improving transplant outcomes and patient survival rates.


Asunto(s)
Ácidos y Sales Biliares , Trasplante de Hígado , Hígado , Perfusión , Microextracción en Fase Sólida , Ácidos y Sales Biliares/análisis , Ácidos y Sales Biliares/metabolismo , Perfusión/métodos , Animales , Microextracción en Fase Sólida/métodos , Hígado/química , Hígado/metabolismo , Masculino , Preservación de Órganos/métodos , Espectrometría de Masas , Humanos
6.
J Pharm Anal ; 14(2): 196-210, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38464782

RESUMEN

Adjuvant chemotherapy improves the survival outlook for patients undergoing operations for lung metastases caused by colorectal cancer (CRC). However, a multidisciplinary approach that evaluates several factors related to patient and tumor characteristics is necessary for managing chemotherapy treatment in metastatic CRC patients with lung disease, as such factors dictate the timing and drug regimen, which may affect treatment response and prognosis. In this study, we explore the potential of spatial metabolomics for evaluating metabolic phenotypes and therapy outcomes during the local delivery of the anticancer drug, oxaliplatin, to the lung. 12 male Yorkshire pigs underwent a 3 h left lung in vivo lung perfusion (IVLP) with various doses of oxaliplatin (7.5, 10, 20, 40, and 80 mg/L), which were administered to the perfusion circuit reservoir as a bolus. Biocompatible solid-phase microextraction (SPME) microprobes were combined with global metabolite profiling to obtain spatiotemporal information about the activity of the drug, determine toxic doses that exceed therapeutic efficacy, and conduct a mechanistic exploration of associated lung injury. Mild and subclinical lung injury was observed at 40 mg/L of oxaliplatin, and significant compromise of the hemodynamic lung function was found at 80 mg/L. This result was associated with massive alterations in metabolic patterns of lung tissue and perfusate, resulting in a total of 139 discriminant compounds. Uncontrolled inflammatory response, abnormalities in energy metabolism, and mitochondrial dysfunction next to accelerated kynurenine and aldosterone production were recognized as distinct features of dysregulated metabolipidome. Spatial pharmacometabolomics may be a promising tool for identifying pathological responses to chemotherapy.

7.
J Agric Food Chem ; 71(49): 19682-19693, 2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-37988651

RESUMEN

Tea (Camellia sinensis) flowers emit a large amount of volatiles that attract pollinators. However, few studies have characterized temporal and spatial variation in tea floral volatiles. To investigate the distribution of volatiles within tea flowers and their variation among opening stages, volatile components from different parts of tea flowers and different opening stages were collected by headspace solid-phase microextraction and analyzed by gas chromatography-mass spectrometry. A total of 51 volatile compounds of eight chemical classes were identified in the tea flowers. Volatile compounds were most abundant in tea flowers of the Shuchazao cultivar. Acetophenone, 1-phenylethanol, 2-phenylethanol, and benzyl alcohol were the most abundant volatiles. Terpenes were common in the sepals, and benzoids were common in the stamens. The fatty acid derivatives were mainly distributed in the pistils and receptacles and were less abundant in the petals, sepals, and stamens. During the opening phase of tea flowers, the volatile content increased 12-fold, which mainly stemmed from the increase in benzoids. These results enhance our understanding of the formation of volatiles in tea flowers.


Asunto(s)
Camellia sinensis , Compuestos Orgánicos Volátiles , Camellia sinensis/química , Flores/química , Terpenos/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Microextracción en Fase Sólida , Té/química , Compuestos Orgánicos Volátiles/química
8.
Chemosphere ; 345: 140460, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37852384

RESUMEN

This work developed a method based on solid phase microextraction followed by gas chromatography/mass spectrometry (SPME-GC/MS) for the measurement of fluorotelomer alcohols (FTOHs) in gas samples. The method quantification limit (MQL) is 6-7 ng/L for 6:2 fluorotelomer alcohols (6:2 FTOH) and 8:2 fluorotelomer alcohols (8:2 FTOH). In contrast to common methods such as thermal desorption combined with GC-MS, it needs neither pre-concentration equipment nor large sample volume. The extraction-evaporation-GC/MS is commonly used in literature for FTOHs measurement in solids samples. We developed a method to measure FTOHs in solid samples by adding solvent extraction prior to headspace SPME-GC/MS. The extraction-headspace SPME-GC/MS method has a quantification limit of 40-43 ng per gram for 6:2 FTOH and 8:2 FTOH in solid samples. This is comparable to the MQLs for the extraction-evaporation-GC/MS method. Removing the solvent evaporation step decreased the risk of contamination and loss of analytes. The developed methods were successfully used in three examples of solid waste study: 1) measuring 6:2 FTOH and 8:2 FTOH above the MQL in gas emissions from a closed landfill, 2) finding 6:2 FTOH above MQL in 9 of 31 solid consumer products, and 3) finding that the release of 6:2 FTOH in simulated landfills containing popcorn bags was linear at a rate of 3.15 ng/g popcorn bags-day and that partial 6:2 FTOH was from the hydrolysis of precursors.


Asunto(s)
Microextracción en Fase Sólida , Residuos Sólidos , Cromatografía de Gases y Espectrometría de Masas/métodos , Residuos Sólidos/análisis , Solventes/análisis , Alcoholes/química
9.
Se Pu ; 41(10): 911-920, 2023 Oct.
Artículo en Chino | MEDLINE | ID: mdl-37875413

RESUMEN

Neurotransmitters (NTs) are essential for intercellular communication and primarily include monoamine, amino acid, and cholinergic NTs. These molecules play important roles in the body's stress response, motor coordination, neuronal communication, and homeostatic functions. Previous studies have shown that abnormal changes in NT levels are associated with various neurological disorders. Therefore, the development of accurate analytical methods for NT detection will enhance the current understanding on complex neuropathophysiology by providing functional knowledge and techniques for early diagnosis, thereby facilitating the development of new therapeutic options for the related diseases. The solid phase microextraction (SPME) technique combines sample preparation, separation, and enrichment in a single step and is minimally invasive, low cost, solvent free, and high throughput. SPME has been successfully applied to the in vivo analysis of target analytes in animal, human, and plant tissues. The coating material plays a significant role in the development of in vivo SPME methods and must meet various analytical requirements, including a suitable geometry for the SPME device, high extraction capacity, excellent selectivity, and wide extraction coverage for the target analytes. Covalent organic frameworks (COFs) are porous crystalline polymers constructed from organic framework units through strong covalent bonds; these materials are characterized with a low density, large specific surface area, permanent porosity, excellent chemical/thermal stability, and easy functionalization.In this study, a sulfonic acid-functionalized COF material (COF-SO3H) with good crystallinity, excellent chemical/thermal stability, strong hydrophobicity, a uniform mesoporous structure, and narrow pore size distribution was prepared using 2,4,6-triformylphloroglucinol and 1,4-diamino-2-nitrobenzene as monomers. Then, the COF-SO3H was coated onto the surface of stainless-steel fibers and used for in vivo enrichment of NTs. The structural properties of COF-SO3H were characterized using various techniques, such as scanning electron microscopy (SEM), Fourier transform-infrared spectroscopy (FT-IR), and X-ray diffraction (XRD), all of which showed that COF-SO3H had a good crystalline structure and uniform mesopore distribution with a specific surface area of 46.17 m2/g. Compared with the SPME fibers of HLB, C18, MCX, amino, and PXC columns, the prepared COF-SO3H fibers showed better extraction efficiency for the target NTs. Next, the factors affecting SPME efficiency were optimized. The optimal desorption solvent was formic acid-methanol-water (0.5∶49.5∶50, v/v/v), and the optimal extraction and desorption times were 15 min. A method for the in vivo analysis of NTs in the brains of mice was established by combining the COF-SO3H fibers with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) under optimal conditions. The NTs were separated on an Acquity UPLC BEH-C18 analytical column (100 mm×2.1 mm, 1.7 µm) with 0.1% formic acid aqueous solution (A) and acetonitrile (B) as the mobile phases. The flow rate was set to 0.2 mL/min, and the gradient elution procedure was as follows: 0-4 min, 5%B-6%B; 4-7 min, 6%B-5%B; 7-11 min, 5%B. Under optimal conditions, the method showed good linearity (r2>0.99). The limits of quantification (S/N≥5) were in the range of 0.003-0.005 µg/mL and 3-5 µg/mL for monoamine and amino acid NTs, respectively, with RSDs of less than 20%. The method showed good precision (0.80%-9.70%) and accuracy (2.08%-17.72%), with absolute matrix effects in the range of 82.22%-117.92%. These values reflect the good purification and enrichment abilities of the proposed fibers for the target analytes. Finally, the established SPME method was combined with UPLC-MS/MS and successfully applied to quantify target NTs in the brains of mice. The proposed strategy provides a practical method for the in vivo detection and quantitative analysis of NTs and expands the applications of functionalized COF materials for the analysis of various targets.


Asunto(s)
Estructuras Metalorgánicas , Humanos , Animales , Ratones , Cromatografía Liquida , Microextracción en Fase Sólida , Espectroscopía Infrarroja por Transformada de Fourier , Espectrometría de Masas en Tándem , Aminas , Aminoácidos , Encéfalo , Neurotransmisores , Extracción en Fase Sólida , Cromatografía Líquida de Alta Presión
10.
Se Pu ; 41(9): 789-798, 2023 Sep.
Artículo en Chino | MEDLINE | ID: mdl-37712543

RESUMEN

Most polycyclic aromatic hydrocarbons (PAHs), which are persistent organic pollutants, have strong carcinogenicity, teratogenicity, and mutagenicity, and pose serious threats to the ecological environment and human health. Owing to the complexity of the matrix and low PAH content of environmental samples, separating and enriching PAHs in environmental samples is necessary prior to their detection. Solid-phase microextraction (SPME) technology is commonly used to detect PAHs owing to its advantages of simple operation, online connection with other instruments, low solvent usage, and integrability of sampling separation, enrichment, and desorption. The extraction coating is the core of this technology, and the type and thickness of the coating are important factors affecting the sensitivity and accuracy of the analysis. Common commercial extraction coatings include polydimethylsiloxane and quartz fiber; however, these materials have a number of disadvantages, such as poor thermal stability and high cost. Several methods, including electrochemical, sol-gel, molecular imprinting, and other coating methods, have been developed to prepare SPME coatings. Electrochemical methods have attracted considerable attention because of their simplicity, short duration, and high coating stability. In the development of an electrochemical method, the selection of the conductive polymer is of particular importance. Polypyrroles (Ppy) are easily synthesized and have numerous advantages, such as good conductivity and stable chemical properties. Thus, their use as a substrate material for SPME coatings is beneficial for improving the overall stability of the coating. Copolymerization with other polymers can enhance the adsorption performance of such coatings via synergistic effects. When doped with inorganic materials with high thermal stability, the composite coating can exhibit high temperature resistance. In this study, a porous boron nitride-doped Ppy-2,3,3-trimethylindole (Ppy/P2,3,3-TMe@In/BN) composite was prepared as a new SPME copolymer coating to detect three PAHs: naphthalene (NAP), acenaphthene (ANY), and fluorene (FLU). Scanning electron microscopy, thermal stability analysis, Fourier transform infrared spectroscopy, and other techniques were used to characterize the Ppy/P2,3,3-TMe@In/BN composite coating. The results showed that the coating featured a large number of porous and wrinkled dendritic structures, which increased the specific surface area of the composite coating and enabled the extensive enrichment of the three PAHs. When the sample inlet temperature of the chromatograph is 320 ℃, the chromatographic baseline of the coating is basically stable. Compared with commercial coatings, the prepared coating had better thermal stability. The coating formed stable intermolecular forces with the three PAHs owing to its numerous carbon-carbon double bonds (C=C), hydrogen bonds, and other structures, thereby achieving excellent enrichment of the target analytes. Compared with Ppy, Ppy/PIn, Ppy/P2,3,3-TMe@In, Ppy/BN, and polydimethylsiloxane (PDMS) coatings, the prepared Ppy/P2,3,3-TMe@In/BN composite coating exhibited better extraction effects for the three PAHs. The Ppy/P2,3,3-TMe@In/BN composite coating was polymerized on the surface of a stainless-steel wire by cyclic voltammetry and combined with gas chromatography-hydrogen flame ionization detection (GC-FID) to optimize the conditions influencing the extraction and separation of the three PAHs, thereby establishing a highly sensitive analytical method for detecting NAP, ANY, and FLU. This method had low limits of detection (LODs) of 10.6-14.5 ng/L (S/N=3) and high stability. The SPME-GC-FID method was used to detect the three PAHs in two environmental water samples, and a small amount of ANY (1.39 µg/L) was detected in one water sample. Satisfactory recoveries (82.5%-113.9%) were obtained when both water samples were spiked with the three PAHs at three levels. The experimental results indicate that the established analytical method can detect the three PAHs in environmental water samples.

11.
Anal Bioanal Chem ; 415(25): 6227-6235, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37587314

RESUMEN

This study developed a method for quantifying eight short-chain fatty acids (SCFAs) in mouse fecal samples using solid-phase microextraction (SPME) coupled with triple quadrupole gas chromatography tandem mass spectrometry. Furthermore, significant factors affecting SCFA analysis, including SPME fiber selection, pH, salting-out agent, and sample collection time, were investigated. Contrary to previous studies, we found that the CAR/PDMS fiber had the highest extraction efficiency for all SCFAs. The optimal extraction efficiency was observed at pH 2.0, particularly for low-molecular-weight SCFAs. NaH2PO4 showed a more effective extraction efficiency than NaCl, owing to its pH stability and less interference with the solvent matrix. Additionally, our results showed that the SCFA concentration increased over collection time. The composition ratio of the eight SCFAs was maintained for up to 24 h; thus, we concluded that samples should be collected within four hours to obtain reliable results. Our findings may improve laboratory methods for SCFA extraction and mouse fecal sample analysis.

12.
J Chromatogr A ; 1707: 464303, 2023 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-37607428

RESUMEN

The herein presented work aims to the development of an easy method for the quantitative determination of parabens and bisphenols in human salivabased on the use of methyl chloroformate as a derivatizing agent, followed by solid-phase microextraction (SPME) and gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) analysis with selected reaction monitoring (SRM). Using multivariate analysis, two derivatization strategies were compared and optimized, demonstrating that the use of methyl chloroformate led to better sensitivity than the classical derivatization by acetic anhydride. Good performance in the sorption process of the derivatized target analytes was obtained using the most recent commercialized overcoated fiber (PDMS/DVB/PDMS). The validation procedure of the final protocol led to satisfactory results in terms of linearity, limit of quantitation, accuracy, and precision. All parabens were quantified from 10 ng/L using the developed method, except for methylparaben, which was quantified from 100 ng/L along with all bisphenols. Intra- and inter-day accuracy and intra- and inter-day precision can be considered satisfactory for all analytes (values between 73% and 118%), except for the inter-day accuracy of BPF. Quite good results also in terms of matrix effect were obtained for the target compounds (range 71% to 118%, RSD% less than 13.6%), except for BPA at the middle concentration and MeP at the lowest concentration. The greenness of the method was evaluated and the results indicated that our approach is more eco-friendly than previously published methods. Based on its characteristics, the presented method can be considered a suitable approach to determine parabens and bisphenols in routine analysis for biomonitoring purposes.


Asunto(s)
Parabenos , Microextracción en Fase Sólida , Humanos , Cromatografía de Gases y Espectrometría de Masas , Saliva , Espectrometría de Masas en Tándem
13.
Foods ; 12(13)2023 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-37444222

RESUMEN

The red flour beetle, Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae), is a major storage pest that could lead to a wide range of damage. Its secretions have a significant impact on the quality of stored grain and food, leading to serious food safety problems such as grain spoilage and food carcinogenesis. This study investigates new detection techniques for grain storage pests to improve grain insect detection in China. The primary volatile organic chemicals (VOCs) in these secretions are identified using headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS). The specific VOCs that are unique to T. castaneum are selected as criteria for determining the presence of T. castaneum in the granary. To obtain more specific VOCs, experiments were designed for the analysis of T. castaneum samples under different extraction times, two types of SPME fibers and two GC-MS devices of different manufacturers. The experimental results showed that 12 VOCs were detected at relatively high levels, seven of which were common and which were not detected in other grains and grain insects. The seven compounds are 1-pentadecene, 2-methyl-p-benzoquinone, 2-ethyl-p-benzoquinone, 1-hexadecene, cis-9-tetradecen-1-ol, m-cresol and paeonol. These seven compounds can be used as volatile markers to identify the presence of T. castaneum, which could serve as a research foundation for the creation of new techniques for T. castaneum monitoring.

14.
Pestic Biochem Physiol ; 192: 105421, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37105641

RESUMEN

In this study, we extracted and identified the active components of the Asian citrus psyllid, Diaphorina citri sex pheromones to provide a basis for further development of sex attractants. Under laboratory conditions, mating activity in D. citri started 3 d after emergence, which peaked at 6-7 d, and mating activity had no obvious peak during the observed period 7:00-21:00 h. Additionally, D. citri males were attracted to the emanations from conspecific females, especially to the n-hexane extracts of the pheromone. A total of 17 compounds were identified from the n-hexane extracts of female and male D. citri by gas chromatography-mass spectrometer (GC-MS). Among them, 13 compounds were identified from the female D. citri n-hexane extracts, of which 7 (dichloromethane, acetic acid, toluene, butyl acetate, ethyl carbamoylacetate, α-pinene, and 1-nonanal) were not found in the male D. citri n-hexane extracts. In addition, a total of 33 compounds were identified from the solid phase microextraction (SPME) volatiles of the male and female D. citri adults. Among these, 17 compounds were identified from the female D. citri volatiles, of which 6 (cycloheptatriene, 5-methyl-2-phenylindole, 1-dodecanol, cis-11-hexadecena, dodecyl aldehyde, and nerylacetone) were not identified in the volatiles of the D. citri males. It was found that males were significantly attracted to 0.1-10 µL/mL acetic acid and 1-nonanal with the selection rates ranging from 62.04%-70.56% and 62.22%-67.22%, respectively. Therefore, the results of this study suggest that acetic acid and 1-nonanal might be the active compounds of the female D. citri sex pheromones.


Asunto(s)
Citrus , Hemípteros , Atractivos Sexuales , Femenino , Masculino , Animales , Atractivos Sexuales/farmacología , Conducta Animal , Ácido Acético , Feromonas
15.
Se Pu ; 41(4): 302-311, 2023 Apr.
Artículo en Chino | MEDLINE | ID: mdl-37005917

RESUMEN

Sample extraction is a crucial step in forensic analysis, especially when dealing with trace and ultra-trace levels of target analytes present in various complex matrices (e. g., soil, biological samples, and fire debris). Conventional sample preparation techniques include Soxhlet extraction and liquid-liquid extraction. However, these techniques are tedious, time-consuming, labor-intensive and require large amounts of solvents, which poses a threat to the environment and health of researchers. Moreover, sample loss and secondary pollution can easily occur during the preparation procedure. Conversely, the solid phase microextraction (SPME) technique either requires a small amount of solvent or no solvent at all. Its small and portable size, simple and fast operation, easy-to-realize automation, and other characteristics thus make it a widely used sample pretreatment technique. More attention was given to the preparation of SPME coatings by using various functional materials, as commercialized SPME devices used in early studies were expensive, fragile, and lacked selectivity. Examples of those functional materials include metal-organic frameworks, covalent organic frameworks, carbon-based materials, molecularly imprinted polymers, ionic liquids, and conducting polymers, all widely used in environmental monitoring, food analysis, and drug detection. However, these SPME coating materials have relatively few applications in forensics. Given the high potential of SPME technology for the in situ and efficient extraction of samples from crime scenes, this study briefly introduces functional coating materials and summarizes the applications of SPME coating materials for the analysis of explosives, ignitable liquids, illicit drugs, poisons, paints, and human odors. Compared to commercial coatings, functional material-based SPME coatings exhibit higher selectivity, sensitivity, and stability. These advantages are mainly achieved through the following approaches: First, the selectivity can be improved by increasing the π-π, hydrogen bonds, and hydrophilic/hydrophobic interactions between the materials and analytes. Second, the sensitivity can be improved by using porous materials or by increasing their porosity. Third, thermal, chemical, and mechanical stability can be improved by using robust materials or fixing the chemical bonding between the coating and substrate. In addition, composite materials with multiple advantages are gradually replacing the single materials. In terms of the substrate, the silica support was gradually replaced by the metal support. This study also outlines the existing shortcomings in forensic science analysis of functional material-based SPME techniques. First, the application of functional material-based SPME techniques in forensic science remains limited. On one hand, the analytes are narrow in scope. As far as explosive analysis is concerned, functional material-based SPME coatings are mainly applied to nitrobenzene explosives, while other categories, such as nitroamine and peroxides, are rarely or never involved. Research and development of coatings is insufficient and the application of COFs in forensic science has not yet been reported. Second, functional material-based SPME coatings have not been commercialized as they don't yet have inter-laboratory validation tests or established official standard analytical methods. Therefore, some suggestions are proposed for the future development of forensic science analyses of functional material-based SPME coatings. First, research and development of functional material-based SPME coatings, especially fiber coatings with broad-spectrum applicability and high sensitivity, or outstanding selectivity for some compounds, is still an important direction for SPME future research. Second, a theoretical calculation of the binding energy between the analyte and coating was introduced to guide the design of functional coatings and improve the screening efficiency of new coatings. Third, we expand its application in forensic science by expanding the number of analytes. Fourth, we focused on the promotion of functional material-based SPME coatings in conventional laboratories and established performance evaluation protocols for the commercialization of functional material-based SPME coatings. This study is expected to serve as a reference for peers engaged in related research.

16.
Anal Bioanal Chem ; 415(18): 4501-4510, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37041278

RESUMEN

In the present work, the potential benefit of using multi-cumulative trapping headspace extraction was explored by comparing the results using solid-phase microextraction (SPME) coated with divinylbenzene/carboxen/polydimethylsiloxane and a probe-like tool coated with polydimethylsiloxane. The efficiency of a single 30-min extraction, already explored in previous work, was compared with that of multiple shorter extractions. We evaluated three different conditions, i.e., three repeated extractions for 10 min each from different sample vials (for both the probe-like tool and SPME) or from the same vial (for SPME) containing brewed coffee. The entire study was performed using comprehensive two-dimensional gas chromatography coupled with mass spectrometry. The two-dimensional plots were aligned and integrated using a tile-sum approach before any statistical analysis. A detailed comparison of all the tested conditions was performed on a set of 25 targeted compounds. Although a single 30-min extraction using the probe-like tool provided a significantly higher compound intensity than SPME single extraction, the use of multiple shorter extractions with SPME showed similar results. However, multiple extractions with the probe-like tool showed a greater increase in the number of extracted compounds. Furthermore, an untargeted cross-sample comparison was performed to evaluate the ability of the two tested tools and the different extraction procedures in differentiating between espresso-brewed coffee samples obtained from capsules made of different packaging materials (i.e., compostable capsules, aluminum capsules, aluminum multilayer pack). The highest explained variance was obtained using the probe-like tool and multiple extractions (91.6% compared to 83.9% of the single extraction); nevertheless, SPME multiple extractions showed similar results with 88.3% of variance explained.


Asunto(s)
Café , Odorantes , Café/química , Cromatografía de Gases y Espectrometría de Masas/métodos , Odorantes/análisis , Aluminio/análisis , Cápsulas , Microextracción en Fase Sólida/métodos , Dimetilpolisiloxanos
17.
Environ Int ; 173: 107857, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36881956

RESUMEN

Perfluoroalkyl substances (PFAS) are persistent and pose a risk to human health. High throughput screening (HTS) cell-based bioassays may inform risk assessment of PFAS provided that quantitative in vitro to in vivo extrapolation (QIVIVE) can be developed. The QIVIVE ratio is the ratio of nominal (Cnom) or freely dissolved concentration (Cfree) in human blood to Cnom or Cfree in the bioassays. Considering that the concentrations of PFAS in human plasma and in vitro bioassays may vary by orders of magnitude, we tested the hypothesis that anionic PFAS bind to proteins concentration-dependently and therefore the binding differs substantially between human plasma and bioassays, which has an impact on QIVIVE. Solid phase microextraction (SPME) with C18-coated fibers served to quantify the Cfree of four anionic PFAS (perfluorobutanoate (PFBA), perfluorooctanoate (PFOA), perfluorohexane sulfonate (PFHxS) and perfluorooctane sulfonate (PFOS)) in the presence of proteins and lipid, medium components, cells and human plasma over five orders of magnitude in concentrations. The C18-SPME method was used to quantify the non-linear binding to proteins, human plasma and medium, and the partition constants to cells. These binding parameters were used to predict Cfree of PFAS in cell bioassays and human plasma by a concentration-dependent mass balance model (MBM). The approach was illustrated with a reporter gene assay indicating activation of the peroxisome proliferator-activated receptor gamma (PPARγ-GeneBLAzer). Blood plasma levels were collected from literature for occupational exposure and the general population. The QIVIVEnom ratios were higher than the QIVIVEfree ratios due to the strong affinity to proteins and large differences in protein contents between human blood and bioassays. For human health risk assessment, the QIVIVEfree ratios of many in vitro assays need to be combined to cover all health relevant endpoints. If Cfree cannot be measured, they can be estimated with the MBM and concentration-dependent distribution ratios.


Asunto(s)
Ácidos Alcanesulfónicos , Contaminantes Ambientales , Fluorocarburos , Humanos , Disponibilidad Biológica , Unión Proteica , Fluorocarburos/toxicidad , Ácidos Alcanesulfónicos/toxicidad , Alcanosulfonatos , Bioensayo
18.
Sensors (Basel) ; 23(4)2023 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-36850915

RESUMEN

A mechanically robust in-tube stainless steel microneedle solid phase microextraction (SPME) platform for dual electrochemical and chromatographic detection has been demonstrated. The SPME microneedle was fabricated by layer-by-layer (LbL) in-tube coating, consisting of carbon nanotube (CNT)/cellulose nanocrystal (CNC) film layered with an electrically conductive polyaniline (PANI) hydrogel layer (PANI@CNT/CNC SPME microneedle (MN)). The PANI@CNT/CNC SPME MN showed effective analysis of caffeine by GC-MS with an LOD of 26 mg/L and excellent precision across the dynamic range. Additionally, the PANI@CNT/CNC SPME MN demonstrated a 67% increase in sensitivity compared to a commercial SPME fiber, while being highly robust for repeated use without loss in performance. For electrochemical detection, the PANI@CNT/CNC SPME MN showed excellent performance for the detection of 3-caffeoylquinic acid (3-CQA). The dynamic range and limits of detection (LOD) for 3-CQA analysis were 75-448 mg/L and 11 mg/L, respectively. The PANI@CNT/CNC SPME MN was demonstrated to accurately determine the caffeine content and 3-CQA in tea samples and dark roast coffee, respectively. The PANI@CNT/CNC SPME MN was used for semiquantitative antioxidant determination and composition analysis in kiwi fruit using electrochemistry and SPME-coupled GC-MS, respectively.

19.
Cancers (Basel) ; 15(4)2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36831694

RESUMEN

Canines can identify prostate cancer with high accuracy by smelling volatile organic compounds (VOCs) in urine. Previous studies have identified VOC biomarkers for prostate cancer utilizing solid phase microextraction (SPME) gas chromatography-mass spectrometry (GC-MS) but have not assessed the ability of VOCs to distinguish aggressive cancers. Additionally, previous investigations have utilized murine models to identify biomarkers but have not determined if the results are translatable to humans. To address these challenges, urine was collected from mice with prostate cancer and men undergoing prostate cancer biopsy and VOCs were analyzed by SPME GC-MS. Prior to analysis, SPME fibers/arrows were compared, and the fibers had enhanced sensitivity toward VOCs with a low molecular weight. The analysis of mouse urine demonstrated that VOCs could distinguish tumor-bearing mice with 100% accuracy. Linear discriminant analysis of six VOCs in human urine distinguished prostate cancer with sensitivity = 75% and specificity = 69%. Another panel of seven VOCs could classify aggressive cancer with sensitivity = 78% and specificity = 85%. These results show that VOCs have moderate accuracy in detecting prostate cancer and a superior ability to stratify aggressive tumors. Furthermore, the overlap in the structure of VOCs identified in humans and mice shows the merit of murine models for identifying biomarker candidates.

20.
Anal Bioanal Chem ; 415(18): 4423-4434, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36840808

RESUMEN

Analysis of biofluids, such as plasma, can be used to investigate occupational pesticide exposure in the agricultural industry. Considering the chemical complexity and variability of plasma samples, any protocol for pesticide analysis should achieve efficient sample cleanup to minimize matrix effects and enhance method sensitivity through analyte pre-concentration. In this work, a high-throughput method was developed for analysis of 79 pesticides, commonly used in agricultural practices, in human plasma, using biocompatible solid-phase microextraction (SPME) coupled to liquid chromatography-tandem mass spectrometry. An SPME method was developed using a biocompatible hydrophilic-lipophilic balance/polyacrylonitrile (HLB/PAN) extraction phase and demonstrated negligible matrix effects. The performance of the developed SPME method was compared to a QuEChERS -Quick, Easy, Cheap, Effective, Rugged, and Safe- method, the most common sample preparation and cleanup approach for pesticide analysis in complex matrices. Comparable accuracy and precision were achieved for both methods, with accuracy values within 70-120% and relative standard deviation < 15%. Overall, the developed SPME and QuEChERS methods extracted 79 out of 82 monitored pesticides in human plasma. The SPME protocol demonstrated higher sensitivity than the QuEChERS method and a drastic reduction of matrix effects.


Asunto(s)