Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 170
Filtrar
1.
Anal Chim Acta ; 1328: 343183, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39266199

RESUMEN

BACKGROUND: Laser-induced breakdown spectroscopy (LIBS) is a versatile analytical technique for element determination in solids, liquids, and gases. However, LIBS suffers from low detection sensitivity and high relative standard deviation (RSD), restricting its large-scale applications. the process of a physical sampling can, in some cases, compromise the mechanical strength of the component under examination. It should be considered that too large laser energy is bound to cause damage to samples which cannot be tolerated in the process of safe production in the nuclear industry. It is necessary to find a method to obtain high elemental signal intensity in low energy laser. RESULTS: Here, we present a novel approach by integrating microwave plasma torch (MPT) with LIBS, referred to as MPT-LIBS, which effectively addresses the limitations associated with traditional LIBS. The MPT-LIBS technique is evaluated using Cu samples with a low laser pulse energy of 0.55 mJ. A remarkable enhancement factor of over 70 for Cu I 521.82 nm line is demonstrated, while that of Cu I 324.75 nm and 327.40 nm lines exceeding two orders of magnitude. Furthermore, the RSDs of all Cu spectral lines are reduced, especially for Cu I 521.82 nm, which is decreased from 11.48 % to 1.36 %. This indicates a significant improvement in signal stability. Characterization of the tested samples using con-focal microscopy reveals that the ablation area of MPT-LIBS is only 1.36 times of that of LIBS. The limit of detection of Cu I 324.75 nm line is reduced from 52.8 ppk to 319 ppm. SIGNIFICANCE AND NOVELTY: This study not only offers valuable guidance for improving signal stability and the limit of detection in LIBS, but also demonstrates minimal sample damage due to its low ablation amount. Consequently, the proposed methodology has the potential to significantly advance LIBS technology, expanding its applicability in industrial applications.

2.
J Anal At Spectrom ; 39(7): 1720-1725, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39220150

RESUMEN

Elemental bioimaging of low abundant elements via laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS) is hampered by a lack of sensitivity. Novel solutions for specific applications have been developed, however there is a need for more universal approaches. Here we investigated the addition of N2 to the ICP carrier gas to increase sensitivity, defined as signal-to-background, for the majority of biologically relevant elements. A gelatine standard that contained 38 elements across the mass range was ablated with increasing amounts of N2 added to the carrier gas post-ablation. The results show that while all elements examined had an increase in signal intensity, some elements did not have a resultant increase in signal-to-background. Sc, V, Mn, Fe, and Se all exhibited a reduction in signal-to-background ratios across all N2 flow rates examined, with the remaining elements experiencing signal-to-background increases from 1.2-7.8x, depending on the N2 flow rate and element. A compromised optimum N2 flow rate was determined for the analysis all elements and used to image endogenous elements in a mouse brain, and antibody-conjugated elements in a quadriceps muscle section. These images confirmed that the addition of N2 to the carrier gas increased the signal-to-background of the analysis, improving image resolution for endogenous elements and low abundant analytes used for immuno-mass spectrometry imaging of biomarkers. These findings offer a promising avenue for advancing the capabilities of LA-ICP-MS in bio-imaging applications.

3.
Anal Chim Acta ; 1324: 343099, 2024 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-39218580

RESUMEN

BACKGROUND: In-cell NMR is a valuable technique for investigating protein structure and function in cellular environments. However, challenges arise due to highly crowded cellular environment, where nonspecific interactions between the target protein and other cellular components can lead to signals broadening or disappearance in NMR spectra. RESULTS: We implemented chemical reduction methylation to selectively modify lysine residues on protein surfaces aiming to weaken charge interactions and recover obscured NMR signals. This method was tested on six proteins varying in molecular size and lysine content. While methylation did not disrupt the protein's native conformation, it successful restored some previously obscured in-cell NMR signals, particularly for proteins with high isoelectric points that decreased post-methylation. SIGNIFICANCE: This study affirms lysine methylation as a feasible approach to enhance the sensitivity of in-cell NMR spectra for protein studies. By mitigating signal loss due to nonspecific interactions, this method expands the utility of in-cell NMR for investigating proteins in their natural cellular environment, potentially leading to more accurate structural and functional insights.


Asunto(s)
Lisina , Resonancia Magnética Nuclear Biomolecular , Lisina/química , Lisina/análisis , Metilación , Proteínas/química , Proteínas/análisis , Humanos
4.
Appl Spectrosc ; : 37028241258101, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38859755

RESUMEN

The enhancement of Raman signals using photonic crystal structures has been the subject of numerous experimental and theoretical studies, leading to a variety of issues and inconsistencies. This paper presents a comprehensive experimental investigation into the impact of alignment between the laser excitation wavelength and the specific position of the photonic band gap on signal enhancement in Raman spectroscopy. By employing one-dimensional (1D) porous silicon photonic crystals, a systematic analysis across a large number of spectra was conducted. The study focused on examining the signal enhancement of both the Raman ∼520 cm-1 silicon band, representing the constituent material of photonic crystal, and the most prominent Raman bands of crystal violet, used as a probe molecule. The probe molecules were both infiltrated into and adsorbed on top of the photonic crystal structure. The obtained experimental results for the contribution of 1D photonic crystals to Raman signal enhancement are much smaller compared to most predictions. The Raman signal of silicon and the signal from the probe molecule are enhanced ≤2.5 times when the laser excitation aligns with the edge of the photonic band gap, strictly defined as the position at the very bottom of the reflectance peak. The results have been discussed within the context of theoretical explanations.

5.
Front Pharmacol ; 15: 1392729, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38895620

RESUMEN

Background: Oligomeric amyloid beta (oAß) is a toxic factor that acts in the early stage of Alzheimer's disease (AD) and may initiate the pathologic cascade. Therefore, detecting oAß has a crucial role in the early diagnosis, monitoring, and treatment of AD. Purpose: The purpose of this study was to evaluate MRI signal changes in different mouse models and the time-dependent signal changes using our novel gadolinium (Gd)-dodecane tetraacetic acid (DOTA)- ob5 aptamer contrast agent. Methods: We developed an MRI contrast agent by conjugating Gd-DOTA-DNA aptamer called ob5 to evaluate its ability to detect oAß deposits in the brain using MRI. A total of 10 control mice, 9 3xTg AD mice, and 11 APP/PS/Tau AD mice were included in this study, with the age of each model being 16 or 36 weeks. A T1-weighted image was acquired at the time points before (0 min) and after injection of the contrast agent at 5, 10, 15, 20, and 25 min. The analyses were performed to compare MRI signal differences among the three groups and the time-dependent signal differences in different mouse models. Results: Both 3xTg AD and APP/PS/Tau AD mouse models had higher signal enhancement than control mice at all scan-time points after injection of our contrast media, especially in bilateral hippocampal areas. In particular, all Tg AD mouse models aged 16 weeks showed a higher contrast enhancement than those aged 36 weeks. For 3xTg AD and APP/PS/Tau AD groups, the signal enhancement was significantly different among the five time points (0 min, 5 min, 10 min, 15 min, 20 min, and 25 min) in multiple ROI areas, typically in the bilateral hippocampus, left thalamus, and left amygdala. Conclusion: The findings of this study suggest that the expression of the contrast agent in different AD models demonstrates its translational flexibility across different species. The signal enhancement peaked around 15-20 min after injection of the contrast agent. Therefore, our novel contrast agent targeting oAß has the potential ability to diagnose early AD and monitor the progression of AD.

6.
Biosensors (Basel) ; 14(6)2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38920609

RESUMEN

Lateral flow immunoassays (LFIAs) are recognized for their practicality in homecare and point-of-care testing, owing to their simplicity, cost-efficiency, and rapid visual readouts. Despite these advantages, LFIAs typically fall short in sensitivity, particularly in detecting viruses such as SARS-CoV-2, thus limiting their broader application. In response to this challenge, we have innovated an approach to substantially enhance LFIA sensitivity. This involves the integration of a water-soluble dextran-methacrylate polymer wall with a 15% grafting degree positioned between the test and control lines on the LFIA strip. This novel modification significantly improved the sensitivity of the assay, achieving detection limits as low as 50 pg mL-1 and enhancing the sensitivity by 5-20-fold relative to existing LFIA kits available on the market. Furthermore, our developed LFIA kit (WSPW-LFIA) demonstrated exceptional specificity for SARS-CoV-2. Coupled with a straightforward fabrication process and robust stability, the WSPW-LFIA represents a promising advancement for real-time in vitro diagnosis across a spectrum of diseases.


Asunto(s)
COVID-19 , Polímeros , SARS-CoV-2 , SARS-CoV-2/inmunología , Humanos , COVID-19/diagnóstico , Inmunoensayo/métodos , Polímeros/química , Técnicas Biosensibles , Antígenos Virales/análisis , Agua , Sensibilidad y Especificidad , Límite de Detección , Prueba Serológica para COVID-19/métodos , Dextranos
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 320: 124679, 2024 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-38906058

RESUMEN

The vertical flow (VF) method improves generation and collection efficiency in Raman spectroscopy. It enhances all Raman signals, including undesired signals of organic solvents having a considerably large Raman cross section. We constructed a Raman spectrometer using the VF method to overcome this drawback and introduced a spatial line rejection mask to eliminate unnecessary bands. In addition, the design of the VF unit was improved to resist organic solvents. A VF unit with a 60-µm pinhole enhanced the signal 168 times. The spatial mask effectively eliminated the large Raman bands of the solvent and enabled a longer exposure time. The increase in the dynamic range improved the signal-to-noise ratio by 10 % in methanol and acetonitrile measurements. Raman spectrometer with the VF method and spatial mask enables us to record the Raman spectrum of solute molecules without the disturbance of solvent bands.

8.
Micromachines (Basel) ; 15(6)2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38930678

RESUMEN

Laboratory automation effectively increases the throughput in sample analysis, reduces human errors in sample processing, as well as simplifies and accelerates the overall logistics. Automating diagnostic testing workflows in peripheral laboratories and also in near-patient settings -like hospitals, clinics and epidemic control checkpoints- is advantageous for the simultaneous processing of multiple samples to provide rapid results to patients, minimize the possibility of contamination or error during sample handling or transport, and increase efficiency. However, most automation platforms are expensive and are not easily adaptable to new protocols. Here, we address the need for a versatile, easy-to-use, rapid and reliable diagnostic testing workflow by combining open-source modular automation (Opentrons) and automation-compatible molecular biology protocols, easily adaptable to a workflow for infectious diseases diagnosis by detection on paper-based diagnostics. We demonstrated the feasibility of automation of the method with a low-cost Neisseria meningitidis diagnostic test that utilizes magnetic beads for pathogen DNA isolation, isothermal amplification, and detection on a paper-based microarray. In summary, we integrated open-source modular automation with adaptable molecular biology protocols, which was also faster and cheaper to perform in an automated than in a manual way. This enables a versatile diagnostic workflow for infectious diseases and we demonstrated this through a low-cost N. meningitidis test on paper-based microarrays.

9.
Front Bioeng Biotechnol ; 12: 1389143, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38832129

RESUMEN

Cells constitute the fundamental units of living organisms. Investigating individual differences at the single-cell level facilitates an understanding of cell differentiation, development, gene expression, and cellular characteristics, unveiling the underlying laws governing life activities in depth. In recent years, the integration of single-cell manipulation and recognition technologies into detection and sorting systems has emerged as a powerful tool for advancing single-cell research. Raman cell sorting technology has garnered attention owing to its non-labeling, non-destructive detection features and the capability to analyze samples containing water. In addition, this technology can provide live cells for subsequent genomics analysis and gene sequencing. This paper emphasizes the importance of single-cell research, describes the single-cell research methods that currently exist, including single-cell manipulation and single-cell identification techniques, and highlights the advantages of Raman spectroscopy in the field of single-cell analysis by comparing it with the fluorescence-activated cell sorting (FACS) technique. It describes various existing Raman cell sorting techniques and introduces their respective advantages and disadvantages. The above techniques were compared and analyzed, considering a variety of factors. The current bottlenecks include weak single-cell spontaneous Raman signals and the requirement for a prolonged total cell exposure time, significantly constraining Raman cell sorting technology's detection speed, efficiency, and throughput. This paper provides an overview of current methods for enhancing weak spontaneous Raman signals and their associated advantages and disadvantages. Finally, the paper outlines the detailed information related to the Raman cell sorting technology mentioned in this paper and discusses the development trends and direction of Raman cell sorting.

10.
Eur Radiol ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750169

RESUMEN

OBJECTIVES: To evaluate signal enhancement ratio (SER) for tissue characterization and prognosis stratification in pancreatic adenocarcinoma (PDAC), with quantitative histopathological analysis (QHA) as the reference standard. METHODS: This retrospective study included 277 PDAC patients who underwent multi-phase contrast-enhanced (CE) MRI and whole-slide imaging (WSI) from three centers (2015-2021). SER is defined as (SIlt - SIpre)/(SIea - SIpre), where SIpre, SIea, and SIlt represent the signal intensity of the tumor in pre-contrast, early-, and late post-contrast images, respectively. Deep-learning algorithms were implemented to quantify the stroma, epithelium, and lumen of PDAC on WSIs. Correlation, regression, and Bland-Altman analyses were utilized to investigate the associations between SER and QHA. The prognostic significance of SER on overall survival (OS) was evaluated using Cox regression analysis and Kaplan-Meier curves. RESULTS: The internal dataset comprised 159 patients, which was further divided into training, validation, and internal test datasets (n = 60, 41, and 58, respectively). Sixty-five and 53 patients were included in two external test datasets. Excluding lumen, SER demonstrated significant correlations with stroma (r = 0.29-0.74, all p < 0.001) and epithelium (r = -0.23 to -0.71, all p < 0.001) across a wide post-injection time window (range, 25-300 s). Bland-Altman analysis revealed a small bias between SER and QHA for quantifying stroma/epithelium in individual training, validation (all within ± 2%), and three test datasets (all within ± 4%). Moreover, SER-predicted low stromal proportion was independently associated with worse OS (HR = 1.84 (1.17-2.91), p = 0.009) in training and validation datasets, which remained significant across three combined test datasets (HR = 1.73 (1.25-2.41), p = 0.001). CONCLUSION: SER of multi-phase CE-MRI allows for tissue characterization and prognosis stratification in PDAC. CLINICAL RELEVANCE STATEMENT: The signal enhancement ratio of multi-phase CE-MRI can serve as a novel imaging biomarker for characterizing tissue composition and holds the potential for improving patient stratification and therapy in PDAC. KEY POINTS: Imaging biomarkers are needed to better characterize tumor tissue in pancreatic adenocarcinoma. Signal enhancement ratio (SER)-predicted stromal/epithelial proportion showed good agreement with histopathology measurements across three distinct centers. Signal enhancement ratio (SER)-predicted stromal proportion was demonstrated to be an independent prognostic factor for OS in PDAC.

11.
Heliyon ; 10(9): e30447, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38720720

RESUMEN

We report an efficient sample preparation method (freezing) for onsite fat and meat analysis via a specially designed thermoelectric cooling and temperature-controlling system. This investigation also focused on the effect of phase change on the sensitivity and reproducibility of LIBS emission signals and plasma parameters. The plasma emissions of animal fats (lard) were recorded when the sample was frozen (-2 °C), fluid (15 °C), and in a liquid state (37 °C) with a thermoelectric cooling system. At each temperature, the plasma emissions were acquired at laser pulse energy from 50 to 300 mJ and detector gate delay (DGD) from 0.5 to 5 µs. With increasing sample temperature, the DGD, where the optical emission intensity reached a maximum, decreased. At a laser pulse energy of 200 mJ and a sample temperature of -2 °C, the emission signals increased fourfold, the signal-to-noise ratio (SNR) improved tenfold, and the self-absorption in the emission lines decreased significantly. The repeatability of the emission signals and plasma parameters of frozen and liquid fat samples was determined using the relative standard deviation (RSD) of Se I (473.08 nm) and K I (766.48 nm) emission lines. The RSDs of the emission signals improved from 40 to 18 % and 37 to 16 %, whereas the shot-to-shot RSDs of the electron temperature and electron number density get improved from 11 to 6 % and 12 to 6.8 %, respectively.

12.
ISA Trans ; 149: 124-136, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38614900

RESUMEN

High-frequency signals like vibration and acoustic emission are crucial for condition monitoring, but their high sampling rates challenge data acquisition, especially for online monitoring. Our research developed a novel method for condition identification in undersampled signals using a modified convolutional neural network integrated with a signal enhancement approach. A frequency-domain filtering is applied to suppress similar sidebands and obtain more discriminative features of different conditions, followed by an interpolation-based upsampling in the time domain to restore the signal length and strengthen the low-frequency harmonic information. Enhanced signals are converted into two-dimensional grayscale images for neural network analysis. Tested on bearing datasets and real-world data from regenerative thermal oxidizer lift valve leakage, our method effectively extracts features from low-frequency signals, achieving over 95% fault identification accuracy.

13.
Artículo en Inglés | MEDLINE | ID: mdl-38640792

RESUMEN

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl3, MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. The choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 µl sample that was 20 µl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07-0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200-50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.


Asunto(s)
Lípidos , Cloroformo/química , Cromatografía de Fase Inversa/métodos , Límite de Detección , Modelos Lineales , Lipidómica/métodos , Lípidos/química , Cromatografía Líquida con Espectrometría de Masas/métodos , Metanol/química , Éteres Metílicos/química , Éteres Metílicos/análisis , Reproducibilidad de los Resultados
14.
ACS Appl Mater Interfaces ; 16(15): 19780-19791, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38584348

RESUMEN

Operando electrochemical attenuated total reflection surface-enhanced infrared absorption spectroscopy (EC ATR-SEIRAS) is a valuable method for a fundamental understanding of electrochemical interfaces under real operating conditions. The applicability of this method depends on the ability to tune the optical and catalytic properties of an electrode film, and it thus requires unique optimization for any given material. Motivated by the growing interest in Sn-based electrocatalysts for selective reduction of CO2 to formate species, we investigate several Sn thin-film synthesis routes for the resulting SEIRA signal response. We compare the SEIRA performance of thermally evaporated metallic Sn to a series of Sn-based films on top of a SEIRA-active Au substrate (metallic Sn, oxide-derived metallic Sn, and metal oxide SnOx). Using alkanethiol self-assembled monolayers as a probe, we find that electrodepositing metallic catalyst films on top of SEIRA-active Au substrates yield higher signal relative to thermal evaporation as well as higher signal than the independent SEIRA-active Au underlayer. These observations come despite the fact that thermally evaporated Sn has a significantly higher surface roughness (and thus higher adsorbate population), suggesting specific SEIRA-magnifying effects for the stacked films. Finally, we applied these films to observe the electrochemical conversion of CO2. Differences are observed in spectral features based on the composition of the electrode being either metallic or oxide-derived metallic Sn, implying differences in their respective reaction pathways.

15.
Ultrasonics ; 138: 107260, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38354525

RESUMEN

As an essential auxiliary tool for acoustic emission (AE) detection, waveguide rods are widely used in testing situations where sensors cannot contact the specimens directly, such as high temperature, cryogenic, corrosion, radiation, etc. However, the AE signal attenuation in waveguide rod makes the risk of missing weak acoustic emission events in damage detection, which limits the application of waveguide rods. Therefore, in this work, a novel waveguide rod was presented based on acoustic black hole (ABH) theory to enhance the AE signal before reaching the sensor through the energy convergence effect of the ABH. Firstly, the geometric configuration of the waveguide rod with ABH was designed. The AE signal enhancement effect of the ABH waveguide rod was verified by comparing the amplitude of the AE signal for the traditional waveguide rod and the ABH waveguide rod by the finite element method. Secondly, the influence on the geometric parameters of the ABH waveguide rod for the AE signal enhancement effect was analyzed. The selection method of geometric parameters and the enhancement method of the AE signal with specific frequency bands were proposed to obtain expected AE signal enhancement results. Finally, the pencil-lead breaking experiments were implemented to verify the effectiveness of finite element method and the AE signal enhancement effect of ABH waveguide rod. The results show that the waveguide rod with ABH given in this paper has a significant AE signal enhancement effect and a good application prospect in structural acoustic emission health monitoring.

16.
Forensic Toxicol ; 42(1): 31-44, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37755669

RESUMEN

PURPOSE: According to recent reports, cannabigerol (CBG) concentration level in blood and body fluids may have forensic utility as a highly specific albeit insensitive biomarker of recent cannabis smoking. While the analytical sensitivity of cannabidiol (CBD), Δ9-tetrahydrocannabinol (Δ9-THC), cannabichromene (CBC) or cannabinol (CBN) estimation by gas chromatography-mass spectrometry (GC-MS) is similar and sufficiently high, it is exceptionally low in the case of CBG (ca. 25 times lower than for the other mentioned cannabinoids). The purpose of this study is to explain the reasons for the extremely low analytical sensitivity of GC-MS in estimating CBG and to present possible ways of its improvement. METHODS: Nuclear magnetic resonance (NMR) data and GC-MS responses to CBG and its various derivatization and transformation products were studied. RESULTS: The validation data of individual derivatives of CBG and its transformation products were established. CBG silylation/acylation or hydration allows to decrease LOD about 3 times, whereas the formation of pyranic CBG derivative leads to 10-times decrease of LOD. The paper enriches the literature of the subject by providing MS and NMR spectra, not published so far, for derivatives of CBG and its transformation products. The most likely cause of low GC-MS response to CBG is also presented. CONCLUSIONS: The presented results shows that although the signal increase of CBG can be obtained through its derivatization by silylation and/or acylation, the greatest increase is observed in the case of its cyclization to the pyranic CBG form during the sample preparation process. The CBG cyclization procedure is very simple and workable in estimating this cannabinoid in blood/plasma samples.


Asunto(s)
Cannabidiol , Cannabinoides , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Cromatografía de Gases y Espectrometría de Masas , Cannabidiol/análisis , Cannabinol/análisis
17.
Chinese Journal of Analytical Chemistry ; (12): 208-219,中插4-中插7, 2024.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1017645

RESUMEN

Amantadine(AMD)residue can accumulate in organisms through the food chain and cause serious harm to human body.AMD can specifically bind to AMD specific aptamer and cause its conformation to change from a random single strand to a stem-loop structure.To avoid the influence of excess nucleotides on binding of aptamer to AMD,the truncation of the AMD original aptamer J was optimized by retaining an appropriate stem-loop structure,and a new type of truncation aptamers was developed in this work.By comparing the truncated aptamer with the original aptamer,it was found that the truncated aptamer J-7 had better affinity and specificity with AMD.The detection limit of AMD was 0.11 ng/mL by using J-7 as specific recognition element and molybdenum disulfide nanosheet(MoS2Ns)as signal amplification element.The developed method base on truncated aptamer J-7 was used for detection of AMD in milk,yogurt and SD rat serum samples for the first time with recoveries of 86.6%-108.2%.This study provided a reference for truncating other long sequence aptamers and provided a more sensitive detection method for monitoring AMD residues in food.

18.
Molecules ; 28(18)2023 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-37764335

RESUMEN

Rapid, highly sensitive, and accurate detection of tumor biomarkers in serum is of great significance in cancer screening, early diagnosis, and postoperative monitoring. In this study, an electrochemiluminescence (ECL) immunosensing platform was constructed by enhancing the ECL signal through in situ growth of platinum nanoparticles (PtNPs) in a nanochannel array, which can achieve highly sensitive detection of the tumor marker carcinoembryonic antigen (CEA). An inexpensive and readily available indium tin oxide (ITO) glass electrode was used as the supporting electrode, and a layer of amino-functionalized vertically ordered mesoporous silica film (NH2-VMSF) was grown on its surface using an electrochemically assisted self-assembly method (EASA). The amino groups within the nanochannels served as anchoring sites for the one-step electrodeposition of PtNPs, taking advantage of the confinement effect of the ultrasmall nanochannels. After the amino groups on the outer surface of NH2-VMSF were derivatized with aldehyde groups, specific recognition antibodies were covalently immobilized followed by blocking nonspecific binding sites to create an immunorecognition interface. The PtNPs, acting as nanocatalysts, catalyzed the generation of reactive oxygen species (ROS) with hydrogen peroxide (H2O2), significantly enhancing the ECL signal of the luminol. The ECL signal exhibited high stability during continuous electrochemical scanning. When the CEA specifically bound to the immunorecognition interface, the resulting immune complexes restricted the diffusion of the ECL emitters and co-reactants towards the electrode, leading to a reduction in the ECL signal. Based on this immune recognition-induced signal-gating effect, the immunosensor enabled ECL detection of CEA with a linear range of 0.1 pg mL-1 to 1000 ng mL-1 with a low limit of detection (LOD, 0.03 pg mL-1). The constructed immunosensor demonstrated excellent selectivity and can achieve CEA detection in serum.

19.
Sensors (Basel) ; 23(18)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37765731

RESUMEN

Oral capillaroscopy is a critical and non-invasive technique used to evaluate microcirculation. Its ability to observe small vessels in vivo has generated significant interest in the field. Capillaroscopy serves as an essential tool for diagnosing and prognosing various pathologies, with anatomic-pathological lesions playing a crucial role in their progression. Despite its importance, the utilization of videocapillaroscopy in the oral cavity encounters limitations due to the acquisition setup, encompassing spatial and temporal resolutions of the video camera, objective magnification, and physical probe dimensions. Moreover, the operator's influence during the acquisition process, particularly how the probe is maneuvered, further affects its effectiveness. This study aims to address these challenges and improve data reliability by developing a computerized support system for microcirculation analysis. The designed system performs stabilization, enhancement and automatic segmentation of capillaries in oral mucosal video sequences. The stabilization phase was performed by means of a method based on the coupling of seed points in a classification process. The enhancement process implemented was based on the temporal analysis of the capillaroscopic frames. Finally, an automatic segmentation phase of the capillaries was implemented with the additional objective of quantitatively assessing the signal improvement achieved through the developed techniques. Specifically, transfer learning of the renowned U-net deep network was implemented for this purpose. The proposed method underwent testing on a database with ground truth obtained from expert manual segmentation. The obtained results demonstrate an achieved Jaccard index of 90.1% and an accuracy of 96.2%, highlighting the effectiveness of the developed techniques in oral capillaroscopy. In conclusion, these promising outcomes encourage the utilization of this method to assist in the diagnosis and monitoring of conditions that impact microcirculation, such as rheumatologic or cardiovascular disorders.


Asunto(s)
Capilares , Enfermedades Cardiovasculares , Humanos , Capilares/diagnóstico por imagen , Angioscopía Microscópica/métodos , Reproducibilidad de los Resultados , Enfermedades Cardiovasculares/patología , Venas , Procesamiento de Imagen Asistido por Computador/métodos
20.
Small ; 19(49): e2303509, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37635118

RESUMEN

Persistent luminescence nanoparticles (PLNPs) are innovative materials able to emit light for a long time after the end of their excitation. Thanks to this property, their detection can be separated in time from the excitation, making it possible to obtain images with a high signal-to-noise ratio. This optical property can be of particular interest for the development of in vitro biosensors. Here, we report the unexpected effect of hydrogen peroxide (H2 O2 ) on the signal intensity of ZnGa2 O4 :Cr3+ (ZGO) nanoparticles. In the presence of H2 O2 , the signal intensity of ZGO can be amplified. This signal amplification can be used to detect and quantify H2 O2 in various media, using non-functionalized ZGO nanoparticles. This small molecule can be produced by several oxidases when they react with their substrate. Indeed, the quantification of glucose, lactic acid, and uric acid is possible. The limit of detection could be lowered by modifying the nanoparticles synthesis route. These optimized nanoparticles can also be used as new biosensor to detect larger molecules such as antigen, using the appropriate antibody. This unique property, i.e., persistent luminescence signal enhancement induced by H2 O2 , represents a new way to detect biomolecules which could lead to a very large number of bioassay applications.


Asunto(s)
Técnicas Biosensibles , Nanopartículas , Luminiscencia , Nanopartículas/química , Técnicas Biosensibles/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA