1.
Contact Dermatitis ; 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39183491

RESUMEN

BACKGROUND: Allergic contact dermatitis (ACD) from protective gloves is often caused by rubber additives, such as accelerators. However, while accelerator-free rubber gloves are available, they still cause ACD in some individuals. OBJECTIVES: A new allergen, 2-cyаnоethyl dimethyldithiocarbamate, (CEDMC), has recently been identified in accelerator-free gloves, and we here provide a first in vitro characterisation of CEDMC in a dendritic cell (DC)-like cell model along with three reference sensitizer rubber chemicals, consisting of tetraethylthiuram disulfide (TETD) and two xanthogenates. METHODS: Cellular responses after the exposure to the rubber chemicals were assessed using a transcriptomic approach, multiplex cytokine secretion profiling, and flow cytometry to determine DC model activation marker expression and apoptosis induction. RESULTS: CEDMC and all other sensitizers were classified as strong skin sensitizers with the transcriptomic approach. They all significantly increased IL-8 secretion and exposure to all except one increased CD86 DC activation marker expression. When tested, CEDMC induced apoptosis, however, delayed compared to TETD. CONCLUSIONS: The in vitro data corroborate CEDMC, TETD, and investigated xanthogenates as skin sensitizers. Transcriptomic analyses further reveal unique cellular responses induced by CEDMC, which together with future study can contribute to better understanding of cellular mechanisms underlying the sensitising capacity of rubber chemicals.

2.
Contact Dermatitis ; 90(2): 116-125, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37735996

RESUMEN

BACKGROUND: Rubber accelerators are used in the production of rubber gloves and may cause contact allergy. OBJECTIVES: To estimate long-term trend and prevalence of contact allergy to rubber accelerators for a 30-year period in Denmark, high-risk occupations, and exposures. METHODS: Data from all patients with contact dermatitis consecutively patch tested at the department of Skin and Allergy Gentofte hospital with the rubber accelerators from the European baseline series (EBS) from 1990 to 2019, were analysed. Further, patients under suspicion of rubber accelerator contact allergy were additionally patch-tested with rubber accelerators from the specialised rubber series from 2005 to 2019 and these were additional extracted. RESULTS: The overall prevalence of contact allergy to one or more of the rubber accelerators from the EBS series was 2.7% with a significant decline in the first 12-years, followed by a stable frequency in the past 18-years. Associations with occupational contact dermatitis, hand dermatitis, and leg/foot dermatitis were found. Wet-work occupations were most often affected and gloves the most frequent exposure. CONCLUSIONS: Contact allergy to one or more of the rubber accelerators from the EBS is frequent and has been unchanged for several decades, which calls for prevention.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Profesional , Eccema , Hipersensibilidad al Látex , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Goma/efectos adversos , Pruebas del Parche/efectos adversos , Dermatitis Profesional/etiología , Dermatitis Profesional/complicaciones , Hipersensibilidad al Látex/epidemiología , Eccema/epidemiología , Eccema/complicaciones , Dinamarca/epidemiología
3.
Int Orthop ; 47(4): 1115-1123, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36565354

RESUMEN

PURPOSE: This study determines the timeline for surgeons adopting rubber gloves and the double glove technique in the operating room for orthopaedic surgery. MATERIAL AND METHODS: Using the vague historical terms of discovery, acceptance, commonplace, and consistency, we analyzed the influence of the different actors in each period. RESULTS: Cotton or silk was used for early gloves; they were permeable, sometimes coated with paraffin. Uses of rubber date to the 1600 s when the Mesoamericans used rubber to make shoes. After the discovery of rubber in 1735 by the French scientist Charles de la Condamine in Peru, the rubber glove was imagined in 1834 and done for the first time by R. F. Cooke. The acceptance of rubber gloves arrived when the Goodyear-Rubber Society began to manufacture rubber gloves. Halsted, at Johns Hopkins Hospital, negotiated in 1889 with the Goodyear Rubber Company to produce thin rubber gloves to protect his nurse's hands from the dermatologic effects of the carbolic acid used to sterilize instruments. Commonplace to protect patients from bacteria of hand surgeons necessitated several decades. Dr. Joseph Bloodgood (Halsted's senior resident) remarked that gloving the surgeon with rubber gloves reduced the infection rate. Still, surgeons were reluctant to wear gloves that impaired the sense of touch. Laboratory experiments performed by G. Perthes on cotton and rubber gloves were necessary to generalize rubber gloves for practice in orthopaedic surgery. Consistency of the double-glove technique arrived during World War II when M. Urist proposed the double protection against bites from bone or bullet fragments while exploring war wounds. Only in 1965, when The Ansell Rubber Company utilized gamma irradiation as a low-cost method of sterilizing the gloves they produced, did disposable gloves become sterile. CONCLUSION: This article helps to understand the detailed discussions before surgical gloves' modern operating equipment.


Asunto(s)
Procedimientos Ortopédicos , Goma , Humanos , Amor , Guantes Quirúrgicos/historia , Quirófanos
4.
IFAC Pap OnLine ; 55(1): 872-877, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-38620994

RESUMEN

The glove manufacturing industry has seen tremendous growth recently, spurred on by the COVID-19 pandemic. A long-standing shortage of supply of disposable medical gloves has highlighted an urgent need to increase production capacity. This requires glove manufacturers to be quick in adopting best practices, in line with Industry 4.0, in order to optimize various aspects of the industry. Unfortunately, information available in the existing literature is, however, limited due to the confidential nature of the majority of research in this area. This article discusses some opportunities and challenges related to this important chemical industry, from the perspective of control engineering. These insights can point to some interesting directions of future work.

5.
Arerugi ; 69(8): 669-677, 2020.
Artículo en Japonés | MEDLINE | ID: mdl-32963190

RESUMEN

BACKGROUND: The causative chemicals responsible for nitrile rubber glove-induced allergic contact dermatitis have not been fully elucidated. SUBJECT: This case involved a 36-year-old female, who developed an erythematous rash on her hands after one and a half months of wearing nitrile rubber gloves at her workplace. METHODS: Patch tests were performed using the gloves as is, and the Japanese standard allergen 2008 and their components. The gloves were chemically analyzed and several detected substances were subjected to further patch testing. RESULTS: The patient exhibited positive patch test reactions to nitrile rubber gloves as is, as well as to the dithiocarbamate mix and thiuram mix in the Japanese standard allergen 2008. Further patch testing revealed positive reactions to zinc diethyldithiocarbamate (ZDEC) and tetraethylthiuram disulfide (TETD) and weak positive reactions to zinc dimethyldithiocarbamate (ZDMC) and tetramethylthiuram monosulfide (TMTM). Chemical analysis revealed that ethyl isothiocyanate (EITC) and butyl isothiocyanate (BITC), which might have been produced from dithiocarbamate-type accelerators (DTCs) or thiuram-type accelerators (thiurams) during the vulcanization process, were present in the nitrile rubber gloves the patient used at her workplace, as was ZDBC. No other DTCs or thiurams were detected. Patch testing of the detected materials produced positive reactions to EITC and BITC, but not to ZDBC. CONCLUSION: We diagnosed the patient with allergic contact dermatitis due to the EITC and BITC present in nitrile rubber gloves, and considered that alkyl isothiocyanate might also have played a causative role. We propose that nitrile rubber gloves should be produced without using vulcanization accelerators.


Asunto(s)
Dermatitis Alérgica por Contacto , Guantes Protectores/efectos adversos , Nitrilos/efectos adversos , Adulto , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Femenino , Humanos , Isotiocianatos/efectos adversos , Pruebas del Parche
6.
Contact Dermatitis ; 81(3): 167-173, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30891769

RESUMEN

BACKGROUND: The frequency of allergic contact dermatitis has significantly increased in healthcare workers since the transition from latex to synthetic rubber gloves, with 1,3-diphenylguanidine being identified as the most frequently implicated allergen. OBJECTIVES: To highlight the role of 1,3-diphenylguanidine as the culprit allergen in contact allergies to synthetic rubber gloves, to propose recommendations for patch testing, and to discuss alternatives for sensitized subjects. MATERIALS AND METHODS: Patch test data from healthcare workers who developed hand dermatitis after wearing rubber gloves and who reacted positively to glove samples and rubber additives were collected from September 2010 to December 2017 in a Belgian hospital. RESULTS: A total of 44 caregivers were included in this study. Patch tests showed that: (a) 84% of the study population reacted positively to carba mix; (b) 86% reacted positively to 1,3-diphenylguanidine; and (c) 13 (30%) reacted positively to thiuram mix. Half of the subjects reacted positively to gloves containing 1,3-diphenylguanidine, whereas none reacted to accelerator-free gloves. CONCLUSION: The most commonly identified allergen was 1,3-diphenylguanidine, far ahead of thiurams, which were previously described as the most sensitizing accelerators. The use of 1,3-diphenylguanidine-free gloves is recommended. No subject reacted to gloves without accelerators, thus confirming their efficiency among accelerator-sensitized patients. We recommend that 1,3-diphenylguanidine be added to the European baseline series.


Asunto(s)
Dermatitis Alérgica por Contacto/etiología , Dermatitis Profesional/etiología , Elastómeros/efectos adversos , Guantes Quirúrgicos/efectos adversos , Guanidinas/efectos adversos , Dermatosis de la Mano/inducido químicamente , Adulto , Ditiocarba/efectos adversos , Femenino , Sector de Atención de Salud , Humanos , Masculino , Persona de Mediana Edad , Pruebas del Parche , Tiram/efectos adversos , Adulto Joven
7.
Contact Dermatitis ; 75(4): 213-22, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27436328

RESUMEN

BACKGROUND: Healthcare workers (HCWs) are at risk of developing occupational skin disease (OSD). OBJECTIVES: To ascertain the causes of OSD in Australian HCWs in a tertiary referral clinic. METHODS: A retrospective review was performed of patients assessed at the Occupational Dermatology Clinic in Melbourne from 1993 to 2014. RESULTS: Of 685 HCWs assessed in the clinic over a period of 22 years, 555 (81.0%) were diagnosed with OSD. The most common diagnosis was irritant contact dermatitis (ICD) (79.1%), followed by allergic contact dermatitis (ACD) (49.7%). Natural rubber latex allergy was also relatively frequent (13.0%). The major substances causing ACD were rubber glove chemicals (thiuram mix and tetraethylthiuram disulfide), preservatives (formaldehyde, formaldehyde releasers, and isothiazolinones), excipients in hand cleansers, which are hard-to-avoid weak allergens, and antiseptics. ACD caused by commercial hand cleansers occurred more frequently than ACD caused by alcohol-based hand rubs (ABHRs). Occupational ICD was mostly caused by water/wet work and hand cleansers, and environmental irritants such as heat and sweating. CONCLUSIONS: Understanding the causes of OSD in HCWs is important in order to develop strategies for prevention. We suggest that skin care advice should be incorporated into hand hygiene education. The use of ABHRs should be encouraged, weak allergens in skin cleansers should be substituted, and accelerator-free gloves should be recommended for HCWs with OSD.


Asunto(s)
Dermatitis Alérgica por Contacto/etiología , Dermatitis Irritante/etiología , Dermatitis Profesional/etiología , Dermatosis de la Mano/etiología , Sector de Atención de Salud , Personal de Salud , Hipersensibilidad al Látex/etiología , Adolescente , Adulto , Anciano , Alérgenos/efectos adversos , Antiinfecciosos Locales/efectos adversos , Australia , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Irritante/diagnóstico , Dermatitis Profesional/diagnóstico , Desinfectantes/efectos adversos , Disulfiram/efectos adversos , Femenino , Formaldehído/efectos adversos , Fungicidas Industriales/efectos adversos , Guantes Protectores/efectos adversos , Dermatosis de la Mano/diagnóstico , Humanos , Irritantes/efectos adversos , Hipersensibilidad al Látex/diagnóstico , Masculino , Persona de Mediana Edad , Pruebas del Parche , Estudios Retrospectivos , Tiram/efectos adversos , Adulto Joven
8.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-495805

RESUMEN

Objective To investigate the comparison of rubber gloves collection bag, linear closing type plastic collection bags and plastic specimen collection bag is used for application effect of laparoscopic ovarian cyst resection. Methods From 2013 June to 2014 December underwent laparoscopic ovarian cyst resection in 90 cases, according to the first date of surgery were divided into 3 groups, from the standard sample collection bag for rubber gloves (A group) 30 cases, linear closing type plastic collection bag (B group) 30 cases, collecting bag plastic specimens (C group) 30 cases. Respectively calculate autologous peritoneal bag mouth opening into time, time to complete transection of tissue into the specimen collection bag time, specimen collection bag left abdominal contents to the in vitro observation time, specimen collection bags in use in the course of rupture occurrence rate of specimen content leakage. Results The 3 groups of patients with autologous abdominal time were (7.18 ± 0.61),(6.72 ± 0.57), (5.98 ± 0.30) s, the difference was not statistically significant (t=41.80, P>0.01). The 3 groups of specimens collected pouch specimens respectively (40.84± 6.27), (49.86 ± 6.10), (32.98 ± 3.93) s, group C open pocket to maintain state of distraction to amputated tissue fully into the specimen collection bag in the shortest time, with a group and B group, the difference was statistically significant (F=69.87, P<0.01). The 3 groups of specimens collected from the abdominal cavity were (498.39±55.60), (315.70±47.32), (448.65±54.90) s, the difference was statistically significant (F=96.18, P < 0.01). The 3 groups of specimens collected specimen bag collection bag rupture were 26.7% (8/ 30),10.0% (3/ 30),3.33% (1/ 30), group A of the most common (χ2=0.926, P < 0.05), The 3 groups of specimens collected the bag contents leakage were 23.30%(7/30), 6.67%(2/30)、3.33%(1/30), group A of frequency was the highest, and in group B and C, the difference had statistical significance (χ2=0.635, P<0.05). Conclusions Plastic type specimen collection bag for soft bag with built-in wire, the bag opening is a certain tension, easy operation by operation control, convenient and reliable safety, shorten operation time, reduce the occurrence of complications, reduce surgical risks and costs, and improve the office efficiency and quality of the operation.

9.
J Phys Ther Sci ; 27(7): 2347-8, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26311980

RESUMEN

[Purpose] The present study examined the effects of wearing rubber gloves on the activities of the forearm and shoulder muscles during two dishwashing stages. [Subjects] This study included 10 young females. [Methods] The participants performed two dishwashing stages (washing and rinsing) with and without rubber gloves. The activities of the wrist flexor and upper trapezius muscles were measured using wireless electromyography. [Results] During the washing stage, the activities of the wrist flexor and upper trapezius muscles were significantly greater without gloves than with gloves when performing the same tasks. However, during the rinsing stage, the activities of these muscles did not differ significantly according to the use of gloves. [Conclusion] Dishwashers should wear gloves during the washing stage to prevent wrist and shoulder pain.

10.
Int J Biol Macromol ; 81: 151-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26234574

RESUMEN

Raspberry-like poly(methyl methacrylate) (PMMA) latex particles stabilized with silica nanoparticles (SiNPs) were prepared via the Pickering emulsion polymerization for use as substrate of N,N,N-trimethyl chitosan (TMC) adsorption. With the aims to simultaneously reduce the surface friction and improve the antibacterial activity of rubber gloves, the synthesized PMMA-SiNPs(TMC) particles were electrostatically deposited onto a sulphur prevulcanized natural rubber (SPNR) latex film. From SEM and AFM analyses, the results showed the highest surface coverage of PMMA-SiNPs(TMC) particles on the surface of SPNR film of 41% and the surface roughness of 69nm. The coated SPNR film exhibited effective antibacterial activity especially against S. aureus. Therefore, this investigation would be useful for fabrication of special gloves with antibacterial properties.


Asunto(s)
Antibacterianos/administración & dosificación , Antibacterianos/química , Quitosano/química , Guantes Quirúrgicos , Microesferas , Nanopartículas/química , Adsorción , Materiales Biocompatibles Revestidos , Emulsiones , Pruebas de Sensibilidad Microbiana , Nanopartículas/ultraestructura , Tamaño de la Partícula , Polimerizacion , Goma/química , Dióxido de Silicio/química , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA