RESUMEN
AIM: Our goal was to compare conformal 3D (C3D) radiotherapy (RT), modulated intensity RT (IMRT), and volumetric modulated arc therapy (VMAT) planning techniques in treating pituitary adenomas. BACKGROUND: RT is important for managing pituitary adenomas. Treatment planning advances allow for higher radiation dosing with less risk of affecting organs at risk (OAR). MATERIALS AND METHODS: We conducted a 5-year retrospective review of patients with pituitary adenoma treated with external beam radiation therapy (C3D with flattening filter, flattening filter-free [FFF], IMRT, and VMAT). We compared dose-volume histogram data. For OARs, we recorded D2%, maximum, and mean doses. For planning target volume (PTV), we registered V95%, V107%, D95%, D98%, D50%, D2%, minimum dose, conformity index (CI), and homogeneity index (HI). RESULTS: Fifty-eight patients with pituitary adenoma were included. Target-volume coverage was acceptable for all techniques. The HI values were 0.06, IMRT; 0.07, VMAT; 0.08, C3D; and 0.09, C3D FFF (pâ¯<â¯0.0001). VMAT and IMRT provided the best target volume conformity (CI, 0.64 and 0.74, respectively; pâ¯<â¯0.0001). VMAT yielded the lowest doses to the optic pathway, lens, and cochlea. The position of the neck in extreme flexion showed that it helps in planning mainly with VMAT by allowing only one arc to be used and achieving the desired conformity, decreasing the treatment time, while allowing greater protection to the organs of risk using C3D, C3DFFF. CONCLUSIONS: Our results confirmed that EBRT in pituitary adenomas using IMRT, VMAT, C3D, C3FFF provide adequate coverage to the target. VMAT with a single arc or incomplete arc had a better compliance with desired dosimetric goals, such as target coverage and normal structures dose constraints, as well as shorter treatment time. Neck extreme flexion may have benefits in treatment planning for better preservation of organs at risk. C3D with extreme neck flexion is an appropriate treatment option when other treatment techniques are not available.
RESUMEN
AIM: Describe characteristics and outcomes of three patients treated with pelvic radiation therapy after kidney transplant. BACKGROUND: The incidence of pelvic cancers in kidney transplant (KT) recipients is rising. Currently it is the leading cause of death. Moreover, treatment is challenging because anatomical variants, comorbidities, and associated treatments, which raises the concern of using radiotherapy (RT). RT has been discouraged due to the increased risk of urethral/ureteral stricture and KT dysfunction. MATERIALS AND METHODS: We reviewed the electronic health records and digital planning system of patients treated with pelvic RT between December 2013 and December 2018 to identify patients with previous KT. CASES DESCRIPTION: We describe three successful cases of KT patients in which modern techniques allowed full standard RT for pelvic malignances (2 prostate and 1 vaginal cancer) with or without elective pelvic nodal RT, without allograft toxicity at short and long follow-up (up to 60 months). CONCLUSION: When needed, RT modern techniques remain a valid option with excellent oncologic results and acceptable toxicity. Physicians should give special considerations to accomplish all OAR dose constraints in the patient's specific setting. Recent publications recommend KT mean dose <4â¯Gy, but graft proximity to CTV makes this unfeasible. We present 2 cases where dose constraint was not achieved, and to a short follow-up of 20 months renal toxicity has not been documented. We recommend the lowest possible mean dose to the KT, but never compromising the CTV coverage, since morbimortality from recurrent or progressive cancer disease outweighs the risk of graft injury.
RESUMEN
AIM: Evaluating the recurrence patterns of high-grade astrocytomas in patients who were treated with radiotherapy (RT) plus temozolomide (TMZ). BACKGROUND: The current literature suggests that reducing the margins added to the CTV does not significantly change the risk of recurrence and overall survival; thus, we decided to analyze our data and to examine the possibility of changing the adopted margins. MATERIALS AND METHODS: From February 2008 till September 2013, 55 patients were treated for high-grade astrocytomas, 20 patients who had been confirmed to have recurrence were selected for the present study. Post-operative MRI was superimposed on the planning CT images in order to correlate the anatomical structures with the treatment targets. Recurrences were defined according to the Response Assessment Criteria for Glioblastoma. The mean margins of the PTVinitial and PTVboost were 1.2 cm and 1.4 cm, respectively. The analysis of the percentage of the recurrence volume (Volrec) within the 100% isodose surface was based on the following criteria: (I) Central: >95% of the Volrec; (II) In-field: 81-95% of the Volrec; (III) Marginal: 20-80% of the Volrec; and (IV) Outside: <20% of the Volrec. RESULTS: Of the 20 patients, 13 presented with central recurrences, 3 with in-field recurrences, 2 with marginal recurrences and 2 with outside recurrences. Therefore, the lower Volrec within 100% of the prescribed dose was considered in the classification. CONCLUSIONS: Of the selected patients, 80% had ≥81-95% of the Volrec within 100% of the prescribed dose and predominantly had central or in-field recurrences. These results are comparable with those from the literature.