RESUMEN
PURPOSE: This article introduces the Pentacam® Cornea OCT (optical coherence tomography). This advanced corneal imaging system combines rotating ultra-high-resolution spectral domain OCT with sub- 2-micron axial resolution and Scheimpflug photography. The purpose of this study is to present the first experience with the instrument and its potential for corneal diagnostics, including optical biopsy. METHODS: In this prospective study, the Pentacam® Cornea OCT was used to image the corneas of seven patients. The novel wide-angle pericentric scan system enables optimal OCT imaging performance for the corneal layer structure over the entire width of the cornea, including the limbal regions. A detailed analysis of the resulting images assessed the synergism between the OCT and Scheimpflug photography. RESULTS: The Pentacam® Cornea OCT demonstrated significantly improved image resolution and ability to individualize corneal layers with high quality. There is a synergism between the OCT high-definition signal to individualize details on the cornea and Scheimpflug photography to detect and quantify corneal scattering. The noncontact exam was proven safe, user-friendly, and effective for enabling optical biopsy. CONCLUSIONS: Pentacam® Cornea OCT is an advancement in corneal imaging technology. The ultra-high-resolution spectral domain OCT and Scheimpflug photography provide unprecedented detail and resolution, enabling optical biopsy and improving the understanding of corneal pathology. Further studies are necessary to compare and analyze the tomographic reconstructions of the cornea with the different wavelengths, which may provide helpful information for diagnosing and managing corneal diseases.
RESUMEN
Objetivo: Determinar parámetros aberrométricos de la córnea para la detección del queratocono subclínico. Métodos: Se realizó un estudio observacional, analítico de corte transversal que incluyó 36 pacientes con queratocono subclínico (grupo de estudio) y 36 estudiantes con córneas aparentemente sanas (grupo control), que asistieron a la consulta de córnea del Instituto Cubano de Oftalmología Ramón Pando Ferrer, entre mayo de 2018 y junio de 2022. Se analizaron topografía y aberrometría corneal con el tomógrafo corneal Pentacam AXL. Resultados: El grupo queratocono subclínico mostró valores similares para la queratometría, asfericidad corneal, paquimetría y el valor total de desviación en comparación con el grupo normal. Hubo diferencias estadísticamente significativas en los parámetros aberrométricos, como el coma a 90º (Z3 -1), y la raíz cuadrada media de las aberraciones de alto orden, de cara anterior, posterior y total corneal, en queratocono subclínico en comparación con el grupo normal. El coma posterior a 90º presentó un área bajo la curva (0,894) mayor dentro de las aberrometrías, con un punto de corte de -0,013 µm, con sensibilidad del 86,1 por ciento y especificidad del 88,9 por ciento. Conclusiones: El coma posterior a 90º (parámetro aberrométrico) presenta una alta sensibilidad y especificidad para el diagnóstico de queratocono subclínico, mediante el análisis tomográfico Pentacam AXL(AU)
Objective: To determine corneal aberrometric parameters for the detection of subclinical keratoconus. Methods: An observational, analytical, cross-sectional study was performed including 36 patients with subclinical keratoconus (study group) and 36 students with apparently healthy corneas (control group), who attended the cornea consultation at the Cuban Institute of Ophthalmology Ramón Pando Ferrer, between May 2018 and June 2022. Corneal topography and aberrometry were analyzed with the Pentacam AXL corneal tomographer. Results: The subclinical keratoconus group showed similar values for keratometry, corneal asphericity, pachymetry and total deviation value compared to the normal group. There were statistically significant differences in aberrometric parameters, such as coma at 90° (Z3-1), and root mean square of high-order anterior, posterior and total corneal aberrations in subclinical keratoconus compared to the normal group. The 90° posterior coma presented a higher area under the curve (0.894) within the aberrometries, with a cutoff point of -0.013 µm, with sensitivity of 86.1 percent and specificity of 88.9 percent. Conclusions: Coma posterior to 90º (aberrometric parameter) presents high sensitivity and specificity for the diagnosis of subclinical keratoconus, using Pentacam AXL tomographic analysis(AU)
Asunto(s)
Humanos , Femenino , Córnea/anomalías , Aberrometría/métodos , Queratocono/etiología , Estudios Observacionales como AsuntoRESUMEN
Objetivo: Evaluar la densitometría corneal en pacientes con queratocono. Métodos: Se realizó un estudio observacional descriptivo de corte transversal que incluyó 90 pacientes con queratocono (grupo de estudio) y 30 estudiantes con córneas aparentemente sanas (grupo control), que asistieron a la consulta de córnea del Instituto Cubano de Oftalmología Ramón Pando Ferrer, entre mayo del 2018 y junio del 2019. Se seleccionó el ojo derecho de cada caso. Se analizaron densitometría corneal con el tomógrafo corneal Pentacam AXL. Resultados: La densitometría fue mayor en el queratocono respecto a la córnea aparentemente sana, de 0 a 2 mm, en la capa anterior, central, y posterior, respectivamente (p < 0,001). La densitometría aumentó en los 0 a 2 mm en la capa anterior en el grupo moderado y en el grupo avanzado (p < 0,001), y entre los 2-6 mm en la capa central, de 10,86 ± 0,54 en el control, en el queratocono avanzado a 12,35 ± 1,16 y en el moderado a 12,16 ± 1,45 (p < 0,001). La densitometría aumentó en el avanzado de 27,64 ± 3,81, de 22,77 ± 2,14 en el leve, y de 24,04 ± 2,83 en el moderado y en los 0-2 mm, en la capa anterior. Conclusiones: La densitometría es mayor en la córnea queratocónica respecto a la córnea aparentemente sana, además que se incrementa al aumentar la gravedad del queratocono en el área central(AU)
Objective: To evaluate corneal densitometry in patients with keratoconus. Methods: A cross-sectional descriptive observational cross-sectional study was performed including 90 patients with keratoconus (study group) and 30 students with apparently healthy corneas (control group), who attended the cornea consultation at the Cuban Institute of Ophthalmology Ramón Pando Ferrer, between May 2018 and June 2019. The right eye of each case was selected. Corneal densitometry was analyzed with the Pentacam AXL corneal tomographer. Results: Densitometry was higher in keratoconus relative to apparently healthy cornea, from 0 to 2 mm, in the anterior, central, and posterior layer, respectively (p < 0.001). Densitometry increased in the 0 to 2 mm in the anterior layer in the moderate group and in the advanced group (p < 0.001), and between 2-6 mm in the central layer, from 10.86 ± 0.54 in the control, in the advanced keratoconus to 12.35 ± 1.16 and in the moderate to 12.16 ± 1.45 (p < 0.001). Densitometry increased in advanced from 27.64 ± 3.81, from 22.77 ± 2.14 in mild, and from 24.04 ± 2.83 in the moderate and 0-2 mm, in the anterior layer. Conclusions: Densitometry is higher in the keratoconic cornea with respect to the apparently healthy cornea, moreover it increases with increasing severity of keratoconus in the central area(AU)
Asunto(s)
Humanos , Densitometría/métodos , Tomografía de Coherencia Óptica/métodos , Queratocono , Epidemiología Descriptiva , Estudios Observacionales como AsuntoRESUMEN
Purpose: Corneal densitometry analysis provides an objective measurement of corneal transparency in patients undergoing photorefractive keratectomy (PRK). To date, no study that focuses on determining the reliability and smallest real difference (SRD), specifically in PRK candidates, has been published. Methods: The study was conducted at Clínica de Oftalmología Sandiego, Medellín, Colombia. This was a prospective and analytical study. Refractive surgery candidates underwent Pentacam measurements twice with five minutes of difference. Repeatability of measurements was evaluated for every area using Wilcoxon signed-rank test, Spearman's rank-order correlation, and the intraclass correlation coefficient, followed by a within-subjects factor (Sw) finishing with a determination of the SRD for all areas. Bland-Altman plots were created and analyzed. Results: A total of 110 eyes were included. The mean total densitometry was 18.67 ± 1.56 grayscale units (GSU) and 18.65 ± 1.49 GSU for the first and second measurements, respectively. Wilcoxon was non-significant (P > 0.05) while the intraclass correlation coefficient demonstrated an excellent agreement. SRD ranged from 0.21 GSU (posterior × 6-10 mm) to 1.79 GSU (total × 10-12 mm). Anterior depths and 10-12 mm annulus had consistently more variability and greater (worse) SRD. The 10-12 mm annulus showed great dispersion on the Bland-Altman plots. Conclusion: Corneal densitometry has an excellent repeatability in refractive surgery candidates for areas below 10 mm. Any densitometry change ≥1.0 GSU in areas under 10 mm should be considered as well above measurement noise and corresponding to a real change in measured parameters. The 10-12 mm area does not seem to be reliable enough in refractive surgery candidates to warrant surveillance after corneal-based surgery.
Asunto(s)
Córnea , Queratectomía Fotorrefractiva , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados , Densitometría , Córnea/cirugía , Topografía de la CórneaRESUMEN
Purpose: Accurate refraction is arguably the most important parameter for a successful laser vision correction surgery and is based on a combination of manifest and cycloplegic refraction. Wavefront-based objective refraction may be useful in the evaluation of patients. So far, the reliability of objective refraction as measured using the Pentacam® AXL Wave has not been published in the literature. Methods: This was a prospective study including a total of 168 eyes belonging to 84 young non-presbyopic patients evaluated for refractive surgery. Pentacam® AXL Wave full sequence was taken for all patients. Then, a clinician who was unaware of the objective refraction results performed a full physical examination, including manifest refraction starting from an autorefractometer value. All refraction values were transferred to astigmatic power vectors as per the Thibos method. Reliability of the different vectors and a unifying blur value were compared using Spearman correlation, Bland-Altman plot, and intraclass correlation coefficient. Results: The mean age was 28.8 ± 5.4 years, with a female preponderance (60.7%). The correlation between both eyes was high. The difference in M vector between subjective and objective refraction was 0.16 D, while the difference was 0.04 and 0.01 D for the J0 and J45 vectors, respectively. Paired samples Student t was non-significant for all comparisons. Spearman rho correlations were high (0.666-0.924, all P < 0.001). Intraclass correlation coefficients were also high (0.890-0.966). Bland-Altman plots did not demonstrate any systematic errors. Conclusion: Wavefront-based refractive refraction obtained using the Pentacam® AXL Wave is highly agreeable and correlated with measurements obtained by manifest subjective refraction.
Asunto(s)
Procedimientos Quirúrgicos Refractivos , Pruebas de Visión , Adulto , Femenino , Humanos , Estudios Prospectivos , Refracción Ocular , Reproducibilidad de los Resultados , Pruebas de Visión/métodos , Adulto JovenRESUMEN
Objetivo: Comparar las mediciones biométricas realizadas con el IOL Master 700 y el Pentacam AXL en pacientes miopes con cirugía fotoablativa previa. Métodos: Se realizó un estudio transversal en 103 ojos de 103 pacientes miopes con cirugía fotoablativa previa, atendidos en el período de enero 2019 a enero 2020, en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer". Las variables estudiadas fueron: edad, sexo, equivalente esférico y características biométricas posoperatorias (longitud axial, profundidad de la cámara anterior y queratometrías), así como su relación, aportadas automáticamente por el IOL master 700 y el pentacam AXL para evitar los factores dependientes del operador, tres meses después de la cirugía. El análisis estadístico se realizó con la prueba t para datos pareados, utilizando una significación del 95 por ciento. Resultados: La edad promedio fue de 25,72 ± 4,26 años. Se analizaron 53 ojos derechos y 50 izquierdos, todos tratados con láser de superficie. El equivalente esférico medio fue de -0,06 ± 0,34 dioptrías y el tiempo entre la cirugía y los exámenes fue de 6,32 ± 3,56 meses. No hubo diferencia estadísticamente significativa (p > 0,05) entre la longitud axial y la profundidad de la cámara anterior; mientras que sí la hubo (p < 0,01) con las queratometrías obtenidas con el IOL Master 700, en comparación con los del pentacam AXL. Conclusión: En pacientes miopes con cirugía fotoablativa previa, el IOL Master 700 y el pentacam AXL proveen mediciones biométricas similares, como la longitud axial y la profundidad de la cámara anterior, no así con la queratometría, la cual es diferente(AU)
Objective: Compare the biometric measurements taken with IOL Master 700 and Pentacam AXL in myopic patients with previous photoablative surgery. Methods: A cross-sectional study was conducted of 103 eyes of 103 myopic patients undergoing photoablative surgery at Ramón Pando Ferrer Cuban Institute of Ophthalmology from January 2019 to January 2020. The variables analyzed were age, sex, spherical equivalent and preoperative biometric characteristics (axial length, anterior chamber depth and keratometries) and the relationship to one another, automatically supplied by IOL Master 700 and Pentacam AXL to avoid operator-dependent factors. The analysis was performed three months after surgery. Statistical analysis was based on the paired Student's t-test with a significance level of 95 percent. Results: Mean age was 25.72 ± 4.26 years. Fifty-three right eyes and 50 left eyes were studied, all of them treated with surface laser. Mean spherical equivalent was -0.06 ± 0.34 diopters; the time elapsed between surgery and the tests was 6.32 ± 3.56 months. No statistically significant differences (p > 0.05) were found between axial length and anterior chamber depth, but statistically significant differences (p < 0.01) were observed between the keratometries obtained with IOL Master 700 and Pentacam AXL. Conclusion: IOL Master 700 and Pentacam AXL provide similar biometric measurements for axial length and anterior chamber depth in myopic patients with previous photoablative surgery, but keratometric measurements are different(AU)
Asunto(s)
Humanos , Adulto , Interpretación Estadística de Datos , Paquimetría Corneal/métodos , Rayos Láser , Miopía/etiología , Estudios TransversalesRESUMEN
Objetivo: Comparar las mediciones biométricas realizadas con el IOL Master 500 y el Pentacam AXL. Métodos: Se realizó un estudio transversal en 99 ojos de 99 pacientes miopes con criterio de cirugía fotoablativa, atendidos en el período de enero del año 2019 a enero de 2020, en el Servicio de Cirugía Refractiva del Instituto Cubano de Oftalmología "Ramón Pando Ferrer". Las variables estudiadas fueron edad, sexo, equivalente esférico y características biométricas preoperatorias (longitud axial, profundidad de la cámara anterior y queratometrías), así como su relación, aportadas automáticamente por el IOL Master 500 y el Pentacam AXL para evitar los factores dependientes del operador. El análisis estadístico se realizó con la Prueba t para datos pareados, utilizando una significación del 95 por ciento. Una diferencia con un valor de p < 0,05 fue considerado estadísticamente significativo. Resultados: El 60,61 por ciento de los pacientes eran de sexo femenino y el 39,39 por ciento del masculino, con una edad promedio de 25,67 ± 4,30 años. Se analizaron 51 ojos derechos y 48 izquierdos. El equivalente esférico medio fue de -3,30 ± 1,53 dioptrías. No hubo diferencia estadísticamente significativa entre los valores biométricos (longitud axial, profundidad de la cámara anterior y queratometrías) obtenidos con el IOL Master 500, en comparación con los del Pentacam-AXL (p > 0,05). Conclusión: Las mediciones biométricas (longitud axial, profundidad de la cámara anterior y queratometrías) obtenidas con el IOL Master 500 y el Pentacam-AXL son similares(AU)
Objective: Compare biometric measurements taken with IOL Master 500 and Pentacam AXL. Methods: A cross-sectional study was conducted of 99 eyes of 99 myopic patients with indication of photoablative surgery attending the Refractive Surgery Service at Ramón Pando Ferrer Cuban Institute of Ophthalmology from January 2019 to January 2020. The variables analyzed were age, sex, spherical equivalent and preoperative biometric characteristics (axial length, anterior chamber depth and keratometries) and the relationship to one another, automatically supplied by IOL Master 500 and Pentacam AXL to avoid operator-dependent factors. Statistical analysis was based on the paired T-test with a significance level of 95%. A difference with a p-value < 0.05 was considered to be statistically significant. Results: Of the patients studied, 60.61 percent were female and 39.39 percent were male; mean age was 25.67± 4.30 years. A total 51 right eyes and 48 left eyes were analyzed. Mean spherical equivalent was -3.30 ± 1.53 diopters. No statistically significant difference was found between the biometric values (axial length, anterior chamber depth and keratometries) obtained with IOL Master 500 versus Pentacam AXL (p > 0.05). Conclusion: Similar biometric measurements (axial length, anterior chamber depth and keratometries) are obtained with IOL Master 500 and Pentacam AXL(AU)
Asunto(s)
Humanos , Masculino , Femenino , Adulto , Biometría/métodos , Procedimientos Quirúrgicos Refractivos/métodos , Cámara Anterior/diagnóstico por imagen , Estudios TransversalesRESUMEN
Resumo Objetivo: Observar o grau de concordância das variáveis analisadas entre os dispositivos IOL Master 500 e Pentacam AXL e descrever as medias Métodos: Foram analisados 35 prontuários, totalizando 61 olhos. Todos os pacientes se submeteram à avaliação biométrica nos dois dispositivos, no período de agosto de 2018 a agosto de 2019. Os dados coletados foram: idade, sexo, profundidade da câmara anterior, comprimento axial, K1, K2, poder dióptrico da LIO e alvo refracional. Resultados: As médias das variáveis analisadas entre os dispositivos de biométricos óptica em questão tiveram diferença estatisticamente significante (p<0,05). A regressão linear não apontou influência de nenhuma das variáveis da câmara anterior na diferença de valores do poder dióptrico da LIO e do alvo refracional entre os dispositivos. Conclusão: Não houve concordância estatística entre os dispositivos para as variáveis analisadas. Portanto, deve se evitar intercambiar o uso do Pentacam AXL com o IOL Master 500.
Abstract Objective: Observe the agreement between IOL Master 500 and Pentacam AXL and describe the averages. Methods: We analyzed 35 medical records, totaling 61 eyes. All patients underwent biometric evaluation on both devices from August 2018 to August 2019. The data collected were: age, gender, anterior chamber depth, axial length, K1, K2, biometrics and IOL target. Results: The averages of the variables analyzed between the optical biometric devices in question had a statistically significant difference (p <0.05). Linear regression showed no influence of any anterior chamber variables on the difference in biometrics and target values between the devices. Conclusion: There was no statistical agreement between the devices for the analyzed variables. Therefore, the interchange of Pentacam AXL with IOL Master 500 should be avoided.
Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Anciano , Refracción Ocular , Biometría , Longitud Axial del Ojo , Lentes Intraoculares Multifocales , InterferometríaRESUMEN
Objetivo: comparar los resultados visuales de los pacientes con cirugía refractiva corneal, operados de catarata e implante de lente intraocular, calculado por el método de Maloney y por Pentacam. Métodos: se realizó un estudio descriptivo, prospectivo y longitudinal en 41 ojos de 31 pacientes con catarata y antecedentes de cirugía refractiva corneal, divididos aleatoriamente en dos grupos (1 y 2) con 23 y 18 ojos respectivamente, para calcular el poder corneal por el método de Maloney y por Pentacam, respectivamente, necesario para el cálculo de la lente intraocular a implantar. Resultados: la mayoría de los pacientes tenía antecedentes de queratotomía radial (90,24 pr ciento). El poder dióptrico medio de la lente mediante el método de Maloney fue de 18,8 ± 4,20, mientras que con la lectura queratométrica, medida a 4,0 mm del Pentacam, fue de 18 ± 4,20, con una diferencia media de 0,80 dioptrías ( p= 0,000) asociada a la prueba de los rangos con signo de Wilcoxon. El componente esférico posoperatorio promedio fue de -0,49 ± 0,65 dioptrías en el grupo 1 y de -0,57 ± 0,685 en el grupo 2, con una diferencia entre la esfera observada y la esperada de 0,16 y 0,15 dioptrías respectivamente (p= 0,906), asociada a la prueba U de Mann-Whitney. quedaron emétropes un 43,48 por ciento del grupo 1 y un 50 por ciento del grupo 2. Conclusiones: ambos métodos brindan resultados visuales favorables, pero el cálculo de la lente intraocular a partir de las lecturas queratométricas aportadas por el Pentacam ofrece mejores resultados visuales para los pacientes con antecedentes de cirugía refractiva corneal(AU)
Objective: to compare the visual results of patients operated from cataract and with intraocular lens implantation through corneal refractive surgery and estimated by Maloney's method and Pentacam camera. Methods: prospective, longitudinal and descriptive study conducted in 41 eyes from 31 patients with cataract and history of refractive corneal surgery. They were randomly assigned to two groups (1 and 2) with 23 and 18 eyes, respectively in order to estimate the corneal power of the intraocular lens to be implanted through Maloney's method and Pentacam camera. Results: most of patients had history of radial keratotomy (90.24 percent). The average dioptric power of the lens according to Maloney's method was 18.8 ± 4.20 whereas the kerametric reading, measured at 4.0 mm from Pentacam was 18 ± 4.20, with a mean difference of 0.80 dioptries ((p= 0,000) associated to Wilcoxon's sign range test. The average postoperative spheral component was -0.49 ± 0.65 D in group 1 and -0.57 ± 0.685 in group 2, with a difference between the observed and the expected sphere of 0.16 and 0.15 dioptries, respectively (p= 0.906), associated to Mann-Whitney's U test. In group 1, 43.48 percent and in group 2, 50 percent remained emetropes. Conclusions: Both methods provide favorable visual results, but the calculation of the intraocular lens power through the keratometric readings by Pentacam offers better visual results for patients with a history of refractive corneal surgery(AU)
Asunto(s)
Humanos , Topografía de la Córnea/métodos , Queratotomía Radial/métodos , Implantación de Lentes Intraoculares/efectos adversos , Epidemiología Descriptiva , Estudios Longitudinales , Estudios ProspectivosRESUMEN
Objetivo: comparar los resultados visuales de los pacientes con cirugía refractiva corneal, operados de catarata e implante de lente intraocular, calculado por el método de Maloney y por Pentacam. Métodos: se realizó un estudio descriptivo, prospectivo y longitudinal en 41 ojos de 31 pacientes con catarata y antecedentes de cirugía refractiva corneal, divididos aleatoriamente en dos grupos (1 y 2) con 23 y 18 ojos respectivamente, para calcular el poder corneal por el método de Maloney y por Pentacam, respectivamente, necesario para el cálculo de la lente intraocular a implantar. Resultados: la mayoría de los pacientes tenía antecedentes de queratotomía radial (90,24 pr ciento). El poder dióptrico medio de la lente mediante el método de Maloney fue de 18,8 ± 4,20, mientras que con la lectura queratométrica, medida a 4,0 mm del Pentacam, fue de 18 ± 4,20, con una diferencia media de 0,80 dioptrías ( p= 0,000) asociada a la prueba de los rangos con signo de Wilcoxon. El componente esférico posoperatorio promedio fue de -0,49 ± 0,65 dioptrías en el grupo 1 y de -0,57 ± 0,685 en el grupo 2, con una diferencia entre la esfera observada y la esperada de 0,16 y 0,15 dioptrías respectivamente (p= 0,906), asociada a la prueba U de Mann-Whitney. quedaron emétropes un 43,48 por ciento del grupo 1 y un 50 por ciento del grupo 2. Conclusiones: ambos métodos brindan resultados visuales favorables, pero el cálculo de la lente intraocular a partir de las lecturas queratométricas aportadas por el Pentacam ofrece mejores resultados visuales para los pacientes con antecedentes de cirugía refractiva corneal(AU)
Objective: to compare the visual results of patients operated from cataract and with intraocular lens implantation through corneal refractive surgery and estimated by Maloney's method and Pentacam camera. Methods: prospective, longitudinal and descriptive study conducted in 41 eyes from 31 patients with cataract and history of refractive corneal surgery. They were randomly assigned to two groups (1 and 2) with 23 and 18 eyes, respectively in order to estimate the corneal power of the intraocular lens to be implanted through Maloney's method and Pentacam camera. Results: most of patients had history of radial keratotomy (90.24 percent). The average dioptric power of the lens according to Maloney's method was 18.8 ± 4.20 whereas the kerametric reading, measured at 4.0 mm from Pentacam was 18 ± 4.20, with a mean difference of 0.80 dioptries ((p= 0,000) associated to Wilcoxon's sign range test. The average postoperative spheral component was -0.49 ± 0.65 D in group 1 and -0.57 ± 0.685 in group 2, with a difference between the observed and the expected sphere of 0.16 and 0.15 dioptries, respectively (p= 0.906), associated to Mann-Whitney's U test. In group 1, 43.48 percent and in group 2, 50 percent remained emetropes. Conclusions: Both methods provide favorable visual results, but the calculation of the intraocular lens power through the keratometric readings by Pentacam offers better visual results for patients with a history of refractive corneal surgery(AU)
Asunto(s)
Humanos , Topografía de la Córnea/métodos , Queratotomía Radial/métodos , Implantación de Lentes Intraoculares/efectos adversos , Epidemiología Descriptiva , Estudios Longitudinales , Estudios ProspectivosRESUMEN
Objetivo: comparar las queratometrías obtenidas por el Pentacam y el método de Maloney en pacientes con catarata, operados previamente de cirugía refractiva corneal. Métodos: se realizó un estudio descriptivo, longitudinal, prospectivo y comparativo entre los valores queratométricos obtenidos mediante el método de Maloney y el Pentacam en pacientes con catarata y cirugía refractiva corneal previa. Se estudiaron 41 ojos de 31 pacientes distribuidos en dos grupos, con 23 y 18 ojos para Maloney y Pentacam respectivamente. La información de la base de datos fue procesada con el software SPSS versión 11.0 para Window. Se trabajó con un nivel de confianza del 95 por ciento y de error inferior al 0,05 por ciento. Resultados: en ambos grupos prevaleció el astigmatismo miópico (simple o compuesto), lo cual se encontró en 14 ojos (60,9 por ciento) del grupo 1 y 16 ojos (89 por ciento) del grupo 2. La mayoría de los ojos estudiados (37) tenían queratotomía radiada, y solo 4,3 del Grupo 1 y 1 del Grupo 2 tenían LASEK miópico. La queratometría promedio obtenida por el método de Maloney fue de 37,55 D, mientras que el valor promedio brindado por el Pentacam (EKR a 4,0 mm) fue de 39,18 D, con una diferencia promedio de 1,64 D, que fue significativa (p= 0,019). Conclusiones: los valores queratométricos aportados por el método de Maloney y las EKR a 4,0 mm del modo Holladay Report del Pentacam presentan diferencias significativas en pacientes con queratotomía radiada previa(AU)
Objective: to compare the keratometries with Pentacam and with Maloney method in patients with cataract, who had previously undergone refractive corneal surgery.Methods: comparative, prospective, descriptive and longitudinal study of keratometric values estimated with Pentacam camera and with Maloney's method in patients with cataract and previous corneal refractive surgery. Forty one eyes were distributed into two groups; twenty three were studied by Maloney method and 18 by Pentacam. Database information was processed by was processed by version 11.0 SPSS software for Windows. The confidence interval was 95 percent and the error margin below 0.05 percent. Results: myopic astigmatism (simple or compound) prevailed and it was found in 14 eyes (60.9 percent) of Group 1 and in 16 eyes (89 percent) of group 2. Most of the studied eyes (37) had radiated keratotomy and just 4.3 in group 1 and one in group 2 had myopic LASEK. The average keratometry with Maloney's method was 37.55 D whereas the average value provided by the Pentacam (EKR at 4,0 mm) was 39.18 D, with a significant average difference of 1.64 D (p= 0.019).Conclusions: the keratometric values estimated by Maloney's method and the EKR at 4,0 mm from the Holladay Report of Pentacam show significant differences in patients with previous radiated keratotomy(AU)
Asunto(s)
Humanos , Cirugía Laser de Córnea/métodos , Extracción de Catarata/métodos , Queratotomía Radial/estadística & datos numéricos , Procedimientos Quirúrgicos Refractivos/efectos adversos , Epidemiología Descriptiva , Estudios Prospectivos , Estudios LongitudinalesRESUMEN
Objetivo: comparar las queratometrías obtenidas por el Pentacam y el método de Maloney en pacientes con catarata, operados previamente de cirugía refractiva corneal. Métodos: se realizó un estudio descriptivo, longitudinal, prospectivo y comparativo entre los valores queratométricos obtenidos mediante el método de Maloney y el Pentacam en pacientes con catarata y cirugía refractiva corneal previa. Se estudiaron 41 ojos de 31 pacientes distribuidos en dos grupos, con 23 y 18 ojos para Maloney y Pentacam respectivamente. La información de la base de datos fue procesada con el software SPSS versión 11.0 para Window. Se trabajó con un nivel de confianza del 95 por ciento y de error inferior al 0,05 por ciento. Resultados: en ambos grupos prevaleció el astigmatismo miópico (simple o compuesto), lo cual se encontró en 14 ojos (60,9 por ciento) del grupo 1 y 16 ojos (89 por ciento) del grupo 2. La mayoría de los ojos estudiados (37) tenían queratotomía radiada, y solo 4,3 del Grupo 1 y 1 del Grupo 2 tenían LASEK miópico. La queratometría promedio obtenida por el método de Maloney fue de 37,55 D, mientras que el valor promedio brindado por el Pentacam (EKR a 4,0 mm) fue de 39,18 D, con una diferencia promedio de 1,64 D, que fue significativa (p= 0,019). Conclusiones: los valores queratométricos aportados por el método de Maloney y las EKR a 4,0 mm del modo Holladay Report del Pentacam presentan diferencias significativas en pacientes con queratotomía radiada previa(AU)
Objective: to compare the keratometries with Pentacam and with Maloney method in patients with cataract, who had previously undergone refractive corneal surgery. Methods: comparative, prospective, descriptive and longitudinal study of keratometric values estimated with Pentacam camera and with Maloney's method in patients with cataract and previous corneal refractive surgery. Forty one eyes were distributed into two groups; twenty three were studied by Maloney method and 18 by Pentacam. Database information was processed by was processed by version 11.0 SPSS software for Windows. The confidence interval was 95 percent and the error margin below 0.05 percent. Results: myopic astigmatism (simple or compound) prevailed and it was found in 14 eyes (60.9 percent) of Group 1 and in 16 eyes (89 percent) of group 2. Most of the studied eyes (37) had radiated keratotomy and just 4.3 in group 1 and one in group 2 had myopic LASEK. The average keratometry with Maloney's method was 37.55 D whereas the average value provided by the Pentacam (EKR at 4,0 mm) was 39.18 D, with a significant average difference of 1.64 D (p= 0.019). Conclusions: the keratometric values estimated by Maloney's method and the EKR at 4,0 mm from the Holladay Report of Pentacam show significant differences in patients with previous radiated keratotomy(AU)
Asunto(s)
Humanos , Femenino , Anciano , Lámina Limitante Anterior/lesiones , Queratitis/diagnóstico , Queratectomía Fotorrefractiva/métodos , Procedimientos Quirúrgicos Refractivos/estadística & datos numéricosRESUMEN
Objetivo: correlacionar los valores queratométricos obtenidos por el programa Holladay Report del Pentacam en ojos operados de queratotomía radial con diagnóstico de catarata, y los obtenidos a través del método de Maloney.Métodos: se realizó un estudio observacional prospectivo y descriptivo a 18 ojos miopes de 14 pacientes portadores de opacidades cristalinianas previamente sometidos a queratotomía radial que acudieron al Servicio de Catarata del Instituto Cubano de Oftalmología Ramón Pando Ferrer en el período comprendido de febrero a noviembre del año 2013. Se utilizó el Pentacam para obtener de forma directa el poder refractivo corneal utilizando programas diseñados con este fin, y posteriormente compararlo con el obtenido por el método de Maloney.Resultados: se obtuvo una correlación positiva al comparar las lecturas queratométricas equivalentes a 1 mm (r= 0,962); 2 mm (r= 0,845); 3 mm (r= 0,985); 4 mm (r= 0,988); 4,5 mm (r= 0,988) y central (r= 0,976) obtenidas en el programa Holladay Report del Pentacam, y los valores queratométricos aportados por el método de Maloney, lo cual fue estadísticamente significativo (p= 0,001). Conclusiones: el programa Holladay Report del Pentacam aporta poderes corneales que no difieren estadísticamente de los obtenidos por el método de Maloney en pacientes con cirugía refractiva corneal previa y catarata con criterio quirúrgico(AU)
Objective: to correlate the keratometric values from the Pentacam´s Holladay Report software in operated eyes which underwent radial keratotomy with cataract diagnosis and those of Maloney´s method. Method: prospective, descriptive and observational study conducted in 18 myopic eyes from 14 patients who had crystalline opacities and had undergone radial keratotomy. They had gone to the cataract service of Ramon Pando Ferrer Cuban Institute of Ophthalmology from February to November 2013. Pentacam was used to directly estimate the corneal refractive power by using tailor-made software for this purpose, and then compare it with the values obtained by Maloney´s method. Results: there was positive correlation when comparing the keratometric readings of 1 mm (r= 0.962); 2 mm (r= 0.845); 3 mm (r= 0.985); 4 mm (r=0.988); 4.5 mm (r= 0.988) and central (r= 0.976) in the Pentacam´s Holladay Report software and the keratometric values of the Maloney's method, which was statistically significant (p= 0,001). Conclusions: pentacam´s Holladay Report software reached corneal power values that do not differ statistically from those of Maloney´s method in patients who had previously undergone corneal refractive surgery and cataract with surgical criteria(AU)
Asunto(s)
Humanos , Tomografía de Coherencia Óptica/métodos , Catarata/diagnóstico , Queratotomía Radial/métodos , Cápsula Posterior del Cristalino/cirugía , Opacidad de la Córnea/cirugía , Epidemiología Descriptiva , Estudios Prospectivos , Estudio ObservacionalRESUMEN
Objetivo: determinar si el sistema Scheimpflug por Pentacam tiene utilidad en la cuantificación objetiva de la opacidad de la cápsula posterior en los pacientes pseudofáquicos con aceite de silicona.Métodos: se realizó un estudio descriptivo, prospectivo y observacional en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" en el período comprendido entre abril del año 2012 y abril de 2014. Se evaluó, mediante sistema Scheimpflug del Pentacam para la cuantificación de la opacidad de cápsula posterior, a un grupo de 31 pacientes seudofáquicos sometidos a una vitrectomía previa con aceite de silicona y se compararon los resultados con los obtenidos en 26 pacientes operados solo de cirugía del cristalino con lente intraocular, para lo cual se utilizaron las variables edad, sexo, opacidad en grados por lámpara de hendidura y la intensidad media de píxeles en un área circular de 3 mm centrales seleccionada en los tomogramas, analizadas por el software Image J 1.42 q. Resultados: en los pacientes pseudofáquicos con aceite de silicona el sistema Scheimpflug no fue capaz de discernir entre los diferentes grados de opacidad de la cápsula posterior(p= 0,210) y no existió concordancia entre ambas mediciones (p= 0,120). Las mediciones realizadas en los pacientes pseudofáquicos con aceite de silicona con la lámpara de hendidura por dos observadores fueron similares (p= 0,042), al igual que existió buena correlación en las realizadas con el sistema Scheimpflug (r= 0,981). Cuando se compararon las mediciones realizadas con el sistema Scheimpflug en los dos grupos de pacientes se observó que las medias de intensidad en los grados 1 y 2 eran superiores a las halladas en los pacientes no vitrectomizados previamente, no así en los grados 3; solo en este último caso la diferencia fue significativa (p= 0,001). Conclusiones: el sistema Scheimpflug no es útil para cuantificar la opacidad de la cápsula posterior en los pacientes vitrectomizado ...(AU)
Objective: to determine whether the Pentacam Scheimpflug imaging system is useful for objective quantification of the posterior capsule opacity in pseudophakic patients with silicon oil-filled eyes.Methods: observational, prospective and descriptive study conducted in Ramon Pando Ferrer Cuban Institute of Ophthalmology in the period of April 2012 through April 2014. With the Pentacam Scheimpflug imaging system for the quantification of the posterior capsule opacity, 31 pseudophakic patients, who had undergone previous vitrectomy with silicon oil, were evaluated and their results were then compared with those of patients operated on through crystalline lens surgery and intraocular lens implantation (26 patients). To this end, the analyzed variables were age, sex, opacification degrees measured with slit lamp and average intensity in pixels in a 3mm round area selected from tomographs and analyzed by Image J 1.42 q software.Results: in pseudophakic patients with silicon oil-filled eyes, the Scheimpflug system could not differentiate the different levels of the posterior capsule opacity (p= 0.210) and there was no agreement between both measurements (p= 0.120). The measurements taken by two observers in pseudophakic patients using silicon oil and slit lamp were similar (p= 0.042) and good correlation in those taken with the Scheimpflug system (r= 0.981). When comparing the Scheimpflug system measurements taken in the two groups of patients, it was observed that the intensity means in grades 1 and 2 were higher than those found in non-vitrectomized patients, but in grade 3, the difference was significant (p= 0.001). Conclusions: Scheimpflug system is not useful to measure the posterior capsule opacity in previously vitrectomized patients who still have silicon oil-filled eyes(AU)
Asunto(s)
Humanos , Anciano , Tomografía/métodos , Cápsula Posterior del Cristalino/cirugía , Opacidad de la Córnea/complicaciones , Aceites de Silicona/uso terapéutico , Seudofaquia/complicaciones , Vitrectomía/métodos , Epidemiología Descriptiva , Estudios Prospectivos , Estudio ObservacionalRESUMEN
Objetivo: correlacionar los valores queratométricos obtenidos por el programa Holladay Report del Pentacam en ojos operados de queratotomía radial con diagnóstico de catarata, y los obtenidos a través del método de Maloney. Métodos: se realizó un estudio observacional prospectivo y descriptivo a 18 ojos miopes de 14 pacientes portadores de opacidades cristalinianas previamente sometidos a queratotomía radial que acudieron al Servicio de Catarata del Instituto Cubano de Oftalmología Ramón Pando Ferrer en el período comprendido de febrero a noviembre del año 2013. Se utilizó el Pentacam para obtener de forma directa el poder refractivo corneal utilizando programas diseñados con este fin, y posteriormente compararlo con el obtenido por el método de Maloney. Resultados: se obtuvo una correlación positiva al comparar las lecturas queratométricas equivalentes a 1 mm (r= 0,962); 2 mm (r= 0,845); 3 mm (r= 0,985); 4 mm (r= 0,988); 4,5 mm (r= 0,988) y central (r= 0,976) obtenidas en el programa Holladay Report del Pentacam, y los valores queratométricos aportados por el método de Maloney, lo cual fue estadísticamente significativo (p= 0,001). Conclusiones: el programa Holladay Report del Pentacam aporta poderes corneales que no difieren estadísticamente de los obtenidos por el método de Maloney en pacientes con cirugía refractiva corneal previa y catarata con criterio quirúrgico(AU)
Objective: to correlate the keratometric values from the Pentacam´s Holladay Report software in operated eyes which underwent radial keratotomy with cataract diagnosis and those of Maloney´s method. Method: prospective, descriptive and observational study conducted in 18 myopic eyes from 14 patients who had crystalline opacities and had undergone radial keratotomy. They had gone to the cataract service of Ramon Pando Ferrer Cuban Institute of Ophthalmology from February to November 2013. Pentacam was used to directly estimate the corneal refractive power by using tailor-made software for this purpose, and then compare it with the values obtained by Maloney´s method. Results: there was positive correlation when comparing the keratometric readings of 1 mm (r= 0.962); 2 mm (r= 0.845); 3 mm (r= 0.985); 4 mm (r=0.988); 4.5 mm (r= 0.988) and central (r= 0.976) in the Pentacam´s Holladay Report software and the keratometric values of the Maloney's method, which was statistically significant (p= 0,001). Conclusions: pentacam´s Holladay Report software reached corneal power values that do not differ statistically from those of Maloney´s method in patients who had previously undergone corneal refractive surgery and cataract with surgical criteria(AU)
Asunto(s)
Humanos , Catarata/diagnóstico , Queratotomía Radial/métodos , Cápsula Posterior del Cristalino/cirugía , Tomografía de Coherencia Óptica/métodos , Opacidad de la Córnea/cirugía , Epidemiología Descriptiva , Estudio Observacional , Estudios ProspectivosRESUMEN
Objetivo: determinar si el sistema Scheimpflug por Pentacam tiene utilidad en la cuantificación objetiva de la opacidad de la cápsula posterior en los pacientes pseudofáquicos con aceite de silicona. Métodos: se realizó un estudio descriptivo, prospectivo y observacional en el Instituto Cubano de Oftalmología Ramón Pando Ferrer en el período comprendido entre abril del año 2012 y abril de 2014. Se evaluó, mediante sistema Scheimpflug del Pentacam para la cuantificación de la opacidad de cápsula posterior, a un grupo de 31 pacientes seudofáquicos sometidos a una vitrectomía previa con aceite de silicona y se compararon los resultados con los obtenidos en 26 pacientes operados solo de cirugía del cristalino con lente intraocular, para lo cual se utilizaron las variables edad, sexo, opacidad en grados por lámpara de hendidura y la intensidad media de píxeles en un área circular de 3 mm centrales seleccionada en los tomogramas, analizadas por el software Image J 1.42 q. Resultados: en los pacientes pseudofáquicos con aceite de silicona el sistema Scheimpflug no fue capaz de discernir entre los diferentes grados de opacidad de la cápsula posterior(p= 0,210) y no existió concordancia entre ambas mediciones (p= 0,120). Las mediciones realizadas en los pacientes pseudofáquicos con aceite de silicona con la lámpara de hendidura por dos observadores fueron similares (p= 0,042), al igual que existió buena correlación en las realizadas con el sistema Scheimpflug (r= 0,981). Cuando se compararon las mediciones realizadas con el sistema Scheimpflug en los dos grupos de pacientes se observó que las medias de intensidad en los grados 1 y 2 eran superiores a las halladas en los pacientes no vitrectomizados previamente, no así en los grados 3; solo en este último caso la diferencia fue significativa (p= 0,001). Conclusiones: el sistema Scheimpflug no es útil para cuantificar la opacidad de la cápsula posterior en los pacientes vitrectomizados previamente que aún tienen aceite de silicona(AU)
Objective: to determine whether the Pentacam Scheimpflug imaging system is useful for objective quantification of the posterior capsule opacity in pseudophakic patients with silicon oil-filled eyes. Methods: observational, prospective and descriptive study conducted in Ramon Pando Ferrer Cuban Institute of Ophthalmology in the period of April 2012 through April 2014. With the Pentacam Scheimpflug imaging system for the quantification of the posterior capsule opacity, 31 pseudophakic patients, who had undergone previous vitrectomy with silicon oil, were evaluated and their results were then compared with those of patients operated on through crystalline lens surgery and intraocular lens implantation (26 patients). To this end, the analyzed variables were age, sex, opacification degrees measured with slit lamp and average intensity in pixels in a 3mm round area selected from tomographs and analyzed by Image J 1.42 q software. Results: in pseudophakic patients with silicon oil-filled eyes, the Scheimpflug system could not differentiate the different levels of the posterior capsule opacity (p= 0.210) and there was no agreement between both measurements (p= 0.120). The measurements taken by two observers in pseudophakic patients using silicon oil and slit lamp were similar (p= 0.042) and good correlation in those taken with the Scheimpflug system (r= 0.981). When comparing the Scheimpflug system measurements taken in the two groups of patients, it was observed that the intensity means in grades 1 and 2 were higher than those found in non-vitrectomized patients, but in grade 3, the difference was significant (p= 0.001). Conclusions: Scheimpflug system is not useful to measure the posterior capsule opacity in previously vitrectomized patients who still have silicon oil-filled eyes(AU)
Asunto(s)
Humanos , Anciano , Opacidad de la Córnea/complicaciones , Cápsula Posterior del Cristalino/cirugía , Seudofaquia/complicaciones , Aceites de Silicona/uso terapéutico , Tomografía/métodos , Epidemiología Descriptiva , Estudio Observacional , Estudios Prospectivos , Vitrectomía/métodosRESUMEN
El desprendimiento de la membrana de Descemet es una complicación infrecuente de la cirugía intraocular que puede resultar devastadora si no se diagnostica y se trata a tiempo. Habitualmente está asociado a la cirugía de la catarata, aunque tiene múltiples etiologías. Existen tratamientos muy variados, desde la simple observación hasta la queratoplastia penetrante. Se presenta una paciente femenina de 66 años de edad, con antecedentes de salud, quien fue operada de catarata del ojo derecho por la técnica de facoemulsificación con implante de lente intraocular de cámara posterior sin complicaciones aparentes durante la cirugía. En el posoperatorio presentó a las 24 horas edema corneal tres cruces con tensión ocular normal, el cual se mantuvo durante la primera semana a pesar del tratamiento intensivo con cloruro de sodio hipertónico y antinflamatorios esteroideos. No se recogieron alteraciones del endotelio corneal previas a la cirugía. En las imágenes de Scheimpflug del pentacam se observó desprendimiento de la membrana de Descemet en distintos puntos. Se realizó neumopexia y a las 24 horas la córnea se encontraba transparente(AU)
Descemet´s membrane detachment is an uncommon complication of the intraocular surgery that can be devastating if it is not diagnosed and treated on time. It is usually associated to cataract surgery, although has multiple etiologies. Treatments vary from the simple observation to the penetrating keratoplasty. This is the case of a 66 year-old woman, with a history of health problems, who was operated on of cataract in her right eye through the phacoemulsification technique with posterior chamber intraocular lens implantation without apparent complications during surgery. After 24 hours, she presented with corneal edema, three crosses and normal ocular pressure. She remained with the same condition during the first week despite treatment with hypertonic sodium chloride and steroid anti-inflammatory drugs. There were no alterations in the corneal endothelium before surgery. Scheimpflug images in Pentacam showed Descemet´s membrane detachment in several sites. It was decided to apply pneumopexia which rendered transparent cornea after other 24 hours(AU)
Asunto(s)
Humanos , Femenino , Anciano , Topografía de la Córnea , Lámina Limitante Posterior , Extracción de Catarata/efectos adversos , Facoemulsificación/métodos , Lentes Intraoculares/efectos adversos , Edema Corneal/terapiaRESUMEN
El desprendimiento de la membrana de Descemet es una complicación infrecuente de la cirugía intraocular que puede resultar devastadora si no se diagnostica y se trata a tiempo. Habitualmente está asociado a la cirugía de la catarata, aunque tiene múltiples etiologías. Existen tratamientos muy variados, desde la simple observación hasta la queratoplastia penetrante. Se presenta una paciente femenina de 66 años de edad, con antecedentes de salud, quien fue operada de catarata del ojo derecho por la técnica de facoemulsificación con implante de lente intraocular de cámara posterior sin complicaciones aparentes durante la cirugía. En el posoperatorio presentó a las 24 horas edema corneal tres cruces con tensión ocular normal, el cual se mantuvo durante la primera semana a pesar del tratamiento intensivo con cloruro de sodio hipertónico y antinflamatorios esteroideos. No se recogieron alteraciones del endotelio corneal previas a la cirugía. En las imágenes de Scheimpflug del pentacam se observó desprendimiento de la membrana de Descemet en distintos puntos. Se realizó neumopexia y a las 24 horas la córnea se encontraba transparente(AU)
Descemet´s membrane detachment is an uncommon complication of the intraocular surgery that can be devastating if it is not diagnosed and treated on time. It is usually associated to cataract surgery, although has multiple etiologies. Treatments vary from the simple observation to the penetrating keratoplasty. This is the case of a 66 year-old woman, with a history of health problems, who was operated on of cataract in her right eye through the phacoemulsification technique with posterior chamber intraocular lens implantation without apparent complications during surgery. After 24 hours, she presented with corneal edema, three crosses and normal ocular pressure. She remained with the same condition during the first week despite treatment with hypertonic sodium chloride and steroid anti-inflammatory drugs. There were no alterations in the corneal endothelium before surgery. Scheimpflug images in Pentacam showed Descemet´s membrane detachment in several sites. It was decided to apply pneumopexia which rendered transparent cornea after other 24 hours(AU)
Asunto(s)
Humanos , Femenino , Anciano , Extracción de Catarata/efectos adversos , Edema Corneal/terapia , Topografía de la Córnea/estadística & datos numéricos , Lámina Limitante Posterior/diagnóstico por imagen , Lentes Intraoculares/efectos adversos , Facoemulsificación/métodosRESUMEN
La opacidad de la cápsula posterior (OCP) es actualmente uno de los aspectos más importantes en la cirugía de catarata de los tiempos modernos. Sigue siendo la complicación posoperatoria tardía más frecuente tras la cirugía de catarata asociada con disminución de la agudeza visual, deterioro de la sensibilidad al contraste y problemas de deslumbramiento que conllevan importantes repercusiones sociales, médicas y económicas. El software PANDOC provee al oftalmólogo de una herramienta por medio de la cual este es capaz de cuantificar numéricamente y detectar diferencias de opacidad (a veces imperceptibles para el ojo humano), logrando así una evaluación objetiva del grado de opacidad y de esta forma minimizar el sesgo de observación entre un médico y otro. Por ello surge la necesidad de identificar automáticamente la OCP en estas imágenes, para lo cual se diseña un sistema basado en casos. La presente investigación se enmarca en la aplicación de un sistema basado en casos integrado al software PANDOC, para identificar y cuantificar objetivamente OCP mediante el uso de las imágenes resultantes de la cámara Scheimpflug del Pentacam(AU)
The posterior capsule opacity (PCO) is nowadays one of the most important aspects in cataract surgery of modern times. It´s still the most frequent post operatory complication associated with visual acuity diminution, deterioration of contrast sensitivity and blinding problems that lead to social, medical and economic repercussions. PANDOC software is a tool for numerical quantification and detection of opacity differences (sometimes imperceptible for human eyes), reaching an objective evaluation of opacity degree and minimizing the observation bias between one doctor and another. For that reason is necessary to identify automatically PCO in these images, for which is designed a case-based system. The present research is oriented to the application of a case-based system for the PANDOC software, to identify and quantify objectively PCO using the resulting images of the Pentacam´sScheimpflug camera(AU)
Asunto(s)
Humanos , Extracción de Catarata/métodos , Opacidad de la CórneaRESUMEN
La opacidad de la cápsula posterior (OCP) es actualmente uno de los aspectos más importantes en la cirugía de catarata de los tiempos modernos. Sigue siendo la complicación posoperatoria tardía más frecuente tras la cirugía de catarata asociada con disminución de la agudeza visual, deterioro de la sensibilidad al contraste y problemas de deslumbramiento que conllevan importantes repercusiones sociales, médicas y económicas. El software PANDOC provee al oftalmólogo de una herramienta por medio de la cual este es capaz de cuantificar numéricamente y detectar diferencias de opacidad (a veces imperceptibles para el ojo humano), logrando así una evaluación objetiva del grado de opacidad y de esta forma minimizar el sesgo de observación entre un médico y otro. Por ello surge la necesidad de identificar automáticamente la OCP en estas imágenes, para lo cual se diseña un sistema basado en casos. La presente investigación se enmarca en la aplicación de un sistema basado en casos integrado al software PANDOC, para identificar y cuantificar objetivamente OCP mediante el uso de las imágenes resultantes de la cámara Scheimpflug del Pentacam(AU)
The posterior capsule opacity (PCO) is nowadays one of the most important aspects in cataract surgery of modern times. It´s still the most frequent post operatory complication associated with visual acuity diminution, deterioration of contrast sensitivity and blinding problems that lead to social, medical and economic repercussions. PANDOC software is a tool for numerical quantification and detection of opacity differences (sometimes imperceptible for human eyes), reaching an objective evaluation of opacity degree and minimizing the observation bias between one doctor and another. For that reason is necessary to identify automatically PCO in these images, for which is designed a case-based system. The present research is oriented to the application of a case-based system for the PANDOC software, to identify and quantify objectively PCO using the resulting images of the Pentacam´sScheimpflug camera(AU)