Rev. Asoc. Odontol. Argent ; 111(3): 3-3, dic. 2023. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1550643

RESUMEN

Resumen Objetivo Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para conectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos A partir de un modelo maestro que representa un maxilar desdentado con cuatro implantes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilladas al modelo maestro. Su desajuste inicial se analizó utilizando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un procedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructura metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significación fue establecido en p<0,05. Resultados El Grupo I tuvo un desajuste inicial de 97,30±13,81μm y el Grupo II de 98,53±11,24μm. Luego de la soldadura, el Grupo I registró 98,53±17,17μm, 1,23μm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61μm, 4,60μm por encima del original. Se analizaron mediante prueba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se observaron diferencias no significativas, p=0,41 y p=0,38 respectivamente. Conclusiones Bajo las condiciones de este estudio, se observó que los dos métodos de soldadura analizados fueron confiables para unir supraestructurasos metálicas sin que se afecte su ajuste final.


Abstract Aim Compare two conventional welding procedures using a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master model. Its initial mismatch was analyzed using a stereoscopic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statistically. The level of significance was established at p<0.05. Results Group I had an initial mismatch of 97.30 ±13.81μm, and Group II of 98.53±11.24μm. After welding, Group I registered 98.53±17.17μm, 1.23μm higher than the initial one. In Group II, 103.13±17.61μm was observed, 4.60μm above the original. They were analyzed using Student's t test; in both cases the result was p>0.05. When comparing groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions Under the conditions of this study, it was observed that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit.

2.
Rev. Asoc. Odontol. Argent ; 111(3): 2-2, dic. 2023. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1550642

RESUMEN

Resumen Objetivo Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para conectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos A partir de un modelo maestro que representa un maxilar desdentado con cuatro implantes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilladas al modelo maestro. Su desajuste inicial se analizó utilizando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un procedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructura metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significación fue establecido en p<0,05. Resultados El Grupo I tuvo un desajuste inicial de 97,30±13,81μm y el Grupo II de 98,53±11,24μm. Luego de la soldadura, el Grupo I registró 98,53±17,17μm, 1,23μm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61μm, 4,60μm por encima del original. Se analizaron mediante prueba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se observaron diferencias no significativas, p=0,41 y p=0,38 respectivamente. Conclusiones Bajo las condiciones de este estudio, se observó que los dos métodos de soldadura analizados fueron confiables para unir supraestructurasos metálicas sin que se afecte su ajuste final.


Abstract Aim Compare two conventional welding procedures using a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master model. Its initial mismatch was analyzed using a stereoscopic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statistically. The level of significance was established at p<0.05. Results Group I had an initial mismatch of 97.30 ±13.81μm, and Group II of 98.53±11.24μm. After welding, Group I registered 98.53±17.17μm, 1.23μm higher than the initial one. In Group II, 103.13±17.61μm was observed, 4.60μm above the original. They were analyzed using Student's t test; in both cases the result was p>0.05. When comparing groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions Under the conditions of this study, it was observed that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit.

3.
Rev. Asoc. Odontol. Argent ; 111(3): 1111212, sept.-dic. 2023. ilus, tab
Artículo en Español | LILACS | ID: biblio-1554482

RESUMEN

Objetivo: Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para co- nectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos: A partir de un modelo maes- tro que representa un maxilar desdentado con cuatro implan- tes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilla- das al modelo maestro. Su desajuste inicial se analizó utili- zando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un pro- cedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructu- ra metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significa- ción fue establecido en p<0,05. Resultados: El Grupo I tuvo un desajuste inicial de 97,30±13,81µm y el Grupo II de 98,53±11,24µm. Luego de la soldadura, el Grupo I registró 98,53±17,17µm, 1,23µm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61µm, 4,60µm por encima del original. Se analizaron mediante prue- ba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se ob- servaron diferencias no significativas, p=0,41 y p=0,38 res- pectivamente (AU)


Aim: Compare two conventional welding procedures us- ing a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods: From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master mod- el. Its initial mismatch was analyzed using a stereoscop- ic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statisti- cally. The level of significance was established at p<0.05. Results: Group I had an initial mismatch of 97.30 ±13.81µm, and Group II of 98.53±11.24µm. After welding, Group I registered 98.53±17.17µm, 1.23µm higher than the initial one. In Group II, 103.13±17.61µm was observed, 4.60µm above the original. They were analyzed using Stu- dent's t test; in both cases the result was p>0.05. When com- paring groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions: Under the conditions of this study, it was ob- served that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit (AU)


Asunto(s)
Soldadura Dental , Retención de Prótesis Dentales/métodos , Ajuste de Prótesis/métodos , Prótesis Dental de Soporte Implantado/métodos , Interpretación Estadística de Datos , Aleaciones de Cromo/síntesis química , Prótesis de Recubrimiento
4.
J Prosthodont ; 2023 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-37470305

RESUMEN

PURPOSE: To evaluate the vertical misfit, stress distribution around dental implants, and cantilever fracture strength of 3-unit implant-supported cantilever fixed partial dentures (FPDs) using frameworks made from different materials and manufacturing techniques. MATERIALS AND METHODS: Forty FPDs were fabricated and divided into 5 groups (n = 8) based on the framework material used: LAS Co-Cr (Conventional casting-laser welding); TIG Co-Cr (Conventional casting -TIG welding); OP Co-Cr (Conventional casting-one-piece); CAD Co-Cr (CAD-CAM); and CAD Zr (CAD-CAM ZrO2 ). The vertical misfit was evaluated before porcelain application (T1) and before (T2), and after thermomechanical cycling (T3) by stereomicroscopy. Cantilever fracture strength was tested with a 50 kN (5000 kgf) load cell at a crosshead speed of 0.5 mm/min. Qualitative and quantitative photoelastic analysis was performed to evaluate stress distribution at seven specific points in five FPDs (n = 1/group) subjected to occlusal loading. RESULTS: Only the molar showed interaction among the three factors (G × S × T; F(20.932) = 1.630; p = 0.044). Thermomechanical cycling (T2 vs. T3) had a significant effect on intra-group vertical misfit in molar, especially in LAS Co-Cr (Δ = 5.87; p = 0.018) and OP Co-Cr (Δ = 5.39; p = 0.007), with no significant effect in premolar (p > 0.05). Ceramic application combined with thermomechanical cycling (T1 vs. T3) caused a significant intra-group increase in vertical misfit in all groups, both in the molar and premolar (p < 0.05). OP Co-Cr was associated with greater vertical misfit and stress concentration. Frameworks manufactured by the CAD-CAM system exhibited lower vertical misfit and better stress distribution. FPDs with metal frameworks (>410.83 ± 72.26 N) showed significantly higher fracture strength (p < 0.05) than zirconia (277.47 ± 39.10 N), and the first signs of ceramic veneering fracture were observed around 900 N. CONCLUSIONS: FPDs with frameworks manufactured using a CAD-CAM system appear to be associated with lower vertical misfit and better stress distribution, although the section of the frameworks followed by welding may be a viable alternative. In addition, metal frameworks exhibit high fracture strength.

5.
Med Biol Eng Comput ; 54(10): 1515-21, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26660895

RESUMEN

Framework misfit is a common problem observed in overdentures, which might result in prosthetic and biological complications. The aim of this study was to evaluate the influence of vertical misfit and clip material on the stress distribution in an overdenture-retaining bar system under masticatory loading. A 3-D finite element model of a resorbed jaw was created, including two implants and a bar-clip retained overdenture. A pressure of 100 MPa was applied to the right mandibular first molar. Different vertical misfit levels (50, 100, and 200 µm) and clip materials (plastic or gold) were evaluated. Data were evaluated using von Mises stress and microstrain. Vertical misfit amplification caused an increase in the microstrain values in the peri-implant bone tissue next to the ill-fitted component and increased the stresses in the prosthetic screws. The clip material influenced the stress and microstrain distribution in the prosthetic components and bone tissue. The levels of vertical misfit seem to be closely linked with the stress values in the prosthetic screws, mainly to that of the ill-fitted component. The gold clip presented an increase in the stress compared to the plastic clip.


Asunto(s)
Análisis del Estrés Dental , Prótesis de Recubrimiento , Masticación , Implantes Dentales , Análisis de Elementos Finitos , Humanos
6.
Braz. dent. j ; Braz. dent. j;25(6): 565-570, Nov-Dec/2014. graf
Artículo en Inglés | LILACS | ID: lil-732255

RESUMEN

The passive fit of implant-supported dentures is fundamental to the rehabilitation success due the absence of the periodontal ligament in osseointegrated implants. Many techniques to obtain passive fit have been reported in the literature, some inaccessible for the clinicians and dental laboratories. This case report presents a technique to fabricate fixed complete dentures aiming at obtain passive fit with reduced time and cost, but without demerit for the aesthetics, function and longevity. A 40-year-old woman was referred for treatment presenting some teeth in the maxilla and an edentulous mandible, reporting eating problems related to instability and little retention of the mandibular complete denture. Treatment based on the reverse planning was performed to guide the rehabilitation with a complete mandibular fixed complete denture and maxillary occlusal plane adjustment. The framework of the fixed complete denture was manufactured luting a cast metal bar above the prepared titanium cylinder abutments using resin cement. The aim of this technique was to obtain a fixed complete denture with passive fit presenting positive esthetic and functional outcomes after 2 years of follow-up.


A adaptação passiva de próteses implantossuportadas é fundamental para o sucesso da reabilitação devido à inexistência de ligamento periodontal em implantes osseointegrados. Inúmeras técnicas de confecção da infraestrutura destas próteses tem sido relatadas na literatura, algumas inacessíveis para os clínicos e laboratórios de prótese. Este relato de caso apresenta uma técnica para confecção de próteses totais fixas visando obtenção de adaptação passiva com tempo e custo reduzido, porém sem demérito à estética, função e longevidade. Uma paciente de 40 anos se apresentou para tratamento apresentando alguns dentes na maxila e mandíbula edêntula, relatando dificuldades na mastigação relacionados a instabilidade e falta de retenção da prótese total inferior. Foi realizado um planejamento reverso para orientar a reabilitação com prótese total mandibular fixa e adequação do plano oclusal da maxila. A infraestrutura da prótese total fixa foi confeccionada pela cimentação de uma barra metálica em cilindros de titânio preparados com cimento resinoso. O objetivo desta técnica foi obter uma prótese total fixa com adaptação passiva apresentando resultados positivos em termos de estética e função após 2 anos de acompanhamento.


Asunto(s)
Animales , Femenino , Masculino , Ratones , Adenocarcinoma/tratamiento farmacológico , Antineoplásicos/uso terapéutico , Neoplasias del Colon/tratamiento farmacológico , Floxuridina/uso terapéutico , Fluorouracilo/uso terapéutico , Adenocarcinoma/patología , Adenocarcinoma/radioterapia , Médula Ósea/patología , Terapia Combinada , Neoplasias del Colon/patología , Neoplasias del Colon/radioterapia , Floxuridina/administración & dosificación , Floxuridina/toxicidad , Fluorouracilo/administración & dosificación , Fluorouracilo/toxicidad , Ratones Endogámicos BALB C , Ratones Endogámicos DBA , Bazo/patología , Timo/patología , Aumento de Peso
7.
Dent. press implantol ; 7(4): 60-74, Oct.-Dec. 2013. ilus
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-727368

RESUMEN

Na cavidade bucal existem estruturas rígidas (dentes) e resilientes (tecidos moles) que deverão ser reproduzidas e, infelizmente, apresentam comportamentos distintos durante o contato com os materiais de moldagem: as estruturas rígidas não sofrem deformações e poderão gerar cópias precisas; as estruturas resilientes sofrerão deformações que precisarão ser convenientemente tratadas para que a prótese não gere traumatismos para os tecidos moles. É fundamental que a transferência espacial dos implantes para o modelo de trabalho gere posicionamentos precisos para os análogos e, com isso, o técnico de laboratório tenha condições de confeccionar peças protéticas que possuam adaptação apropriada em boca. Utilizamos transferentes parafusados em técnica de transferência direta. As moldagens são realizadas em duas etapas: (I) moldagem anatômica com moldeira de estoque e utilização de materiais de moldagem de diferentes consistências, em camadas; (II) moldagem funcional realizada com moldeira individual e poliéteres ou silicones de adição com distintas fluidezes, em camadas. Após a polimerização dos materiais de moldagem, os excessos extravasados devem ser removidos e os transferentes devem ser fixados à moldeira individual de resina com acrílico de baixa contração, pela técnica do pincel. Uma vez polimerizada a resina acrílica, os transferentes devem ser desparafusados e a moldagem removida da cavidade bucal. A transferência anatômico-funcional de múltiplos implantes é fundamental para que possamos obter modelos fiéis, e sobre esses construir próteses que possuam adequada adaptação sobre os implantes e apropriado contacto com os tecidos moles, não gerando traumatismos


In the oral cavity there are ridig structures (teeth) and resilient (soft tissue) to be reproduced and that unfortunately present different behaviors during the contact of impression materials: Rigid structures do not suffer deformation and can generate accurate copies; resilient structures suffer deformations that need to be conveniently performed so that the prosthesis does not create injuries to the soft tissues. It is essential that the spatial transfer of the implants for work model manages precise positioning for analogs and therefore the lab technician is able to fabricate prosthetic piecesd that have an appropriate adaptation to mouth. We use screwed transferents on direct transfer technique. The casts are performed in two steps: (I) anatomical impression with stock tray and use of impression materials of different consistencies, in layers; (II) functional impression with individual tray and polyether or addition-cured silicones of different flows, in layers.After curing the impression materials, spilled excess should be removed and the transferents should be fixed to individual acrylic tray with low shrinkage resin, using the technique of the brush. Once polymerized acrylic resin, transferents must be unscrewed and the impression removed from the oral cavity.The anatomical and functional transfer of multiple implants is essential so that we can get models faithful and build on these prostheses that have adequate fit on the implants and proper contact with soft tissues, generating no injuries.


Asunto(s)
Implantes Dentales , Materiales de Impresión Dental , Técnica de Impresión Dental , Adaptación Marginal Dental , Brasil , Arcada Edéntula , Arcada Parcialmente Edéntula
8.
J Prosthodont Res ; 57(3): 213-8, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23773375

RESUMEN

PURPOSE: To evaluate the influence of different metallic flask systems for acrylic resin denture processing on tooth displacement and framework misfit of mandibular fixed implant-supported complete dentures. METHODS: Standard mandibular implant-supported complete dentures in five implants were waxed and randomly assigned to three groups: G1 - conventional flask, G2 - double flask, and G3 - occlusion flask. Framework misfit in all the implants and the linear distances between teeth (I-I - incisor-to-incisor; P-P - premolar-to-premolar; M-M - molar-to-molar; RI-RM - right-incisor-to-right-molar; and LI-LM - left-incisor-to-left-molar) were measured before and after denture processing using an optical microscope. Dentures were processed by hot water curing cycle (9h/74°C). Collected data were analyzed by paired Student's t-test and one-way ANOVA (α=0.05). RESULTS: All the measured distances presented changes in tooth displacement after denture processing. However, the M-M distance for G1 (p=0.003) and the P-P (p=0.042) and LI-LM (p=0.044) distances for G3 showed statistically significant differences. Differences between the flask systems were not statistically significant. Statistically significant differences in the framework misfit due to denture processing were found for all the implants and groups, with the exception of right median implant for G2 and right distal implant for G3. A comparison of the flask systems found statistically significant differences in which G1 presented an increase in the misfit values and G2 and G3 a decrease. CONCLUSIONS: Different flask systems did not cause significant changes in tooth displacement. Frameworks misfit values were influenced by the different flask systems. The conventional flask presented an increase in the framework misfit, while the experimental flasks showed a decrease.


Asunto(s)
Materiales Dentales , Diseño de Prótesis Dental/efectos adversos , Prótesis Dental de Soporte Implantado , Diseño de Dentadura/efectos adversos , Mandíbula , Metales , Ajuste de Prótesis/efectos adversos , Ajuste de Prótesis/métodos , Movilidad Dentaria/etiología , Diente Artificial , Resinas Acrílicas , Bases para Dentadura , Dentadura Completa Inferior , Falla de Prótesis/efectos adversos , Movilidad Dentaria/prevención & control
9.
ImplantNews ; 10(1): 21-27, 2013. ilus, tab, graf
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-731423

RESUMEN

A adaptação passiva da infraestrutura da prótese sobreimplantes é um dos parâmetros mecânicos que podem interferir na longevidade das próteses. Várias complicações no tratamento com implantes osseointegrados podem ser causadas por deficiência na adaptação das infraestruturas protéticas, podendo ser agravadas pela ausência de ligamento periodontal. O objetivo deste trabalho foi comparar a desadaptação de infraestruturas metálicas em monobloco parafusadas sobreimplante, confeccionadas pelo sistema de fundição por cera perdida e fresadas por sistema CAD/CAM. Sobre um modelo mestre de alumínio foram instalados quatro análogos de minipilares. Sobre estes foram confeccionadas duas barras metálicas: uma fundida em Co-Cr e outra fresada. O desajuste vertical na interface barra/análogos foi mensurado utilizando-se um microscópio comparador. Foi calculada a média de desadaptação em cada um dos pilares (45, 43, 33 e 35) e a média final de desadaptação de cada uma das barras. Na barra metálica fresada observou-se redução nos valores da desadaptação vertical em todos os pilares. A barra metálica fundida mostrou uma desadaptação vertical média (108,6 µm) aproximadamente dez vezes maior do que a barra metálica fresada (9,6 µm).


Passive fit of an implant framework is one of the mechanical parameters that can affect treatment longevity. Several complications in dental implant treatment may be due to misfit of metallic frameworks and can be aggravated by the absence of periodontal ligament. The objective of this study is to compare the misfit of a metallic, one-piece cast and CNC-milled implant frameworks. Four implant analogues were placed in a aluminum master model to receive conical abutments. A Co-Cr alloy was used in both groups. Vertical misfits at implant-framework interface were measured with an optical microscope. Mean misft levels were registered at implant positions 45, 43, 33, and 35, as well as for the overall sample. Individual misfit levels were reduced in CNC-milled frameworks. Cast frameworks showed a mean vertical misfit level (108.6 micrometers) almost 10 times higher than in the milled frameworks (9.6 micrometers).


Asunto(s)
Humanos , Implantación Dental , Prótesis Dental de Soporte Implantado , Prótesis e Implantes
10.
Bauru; s.n; 2011. 154 p. ilus, tab, graf.
Tesis en Portugués | BBO - Odontología | ID: biblio-865821

RESUMEN

A adaptação passiva e estabilidade têm se tornado os dois pré-requisitos de maior importância na escolha dos materiais e técnicas de confecção em prótese implantossuportada. A proposta deste trabalho foi avaliar, com auxílio dos strain gauges ou extensômetros lineares elétricos, a deformação média ocorrida nos intermediários e na região peri-implantar mediante a instalação da infraestrutura parafusada durante sete etapas de confecção da prótese parcial fixa. Para a investigação, foi utilizado um modelo experimental homogêneo à base de poliuretano com dois implantes hexágono externo paralelos entre si. Sobre os implantes foram acoplados pilares Multi-unit de 5 mm de altura que receberam na sua superfície três strain gauges dispostos de maneira eqüidistante entre si. Também foram colados na superfície superior do bloco experimental quatro strain gauges para cada implante, posicionados nas faces mesial, distal, vestibular e lingual visando medir as tensões nestas áreas. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. As leituras foram realizadas em sete momentos, obtendo os valores médios de deformação no poliuretano e no intermediário respectivamente: 1) cilindros de cobalto-cromo pré-fabricados usinados como grupo controle (36,4µε e 87,5µε), 2) infraestrutura sobrefundida em monobloco com liga de níquel-cobalto-cromo (340,3µε e 131,4µε), 3) em seguida seccionada com espaço livre para solda (43,2µε e 66,6µε), 4) seccionada com espaço para solda preenchida com resina acrílica quimicamente ativada (Duralay) (74µε e 86,8µε), 5) seccionada e soldada (280µε e 146,2µε), 6) soldada com aplicação de cerâmica (288,7µε e 151,1µε) e 7) finalizada com aplicação do glaze, acabamento e polimento (359,9µε e 197,8µε). Estes resultados mostraram um aumento crescente da deformação média tanto nos intermediários como no poliuretano...


Passive fit and stability have become the most important prerequisites during the choice of materials and techniques to implant-supported prostheses. Therefore, the aim of this study was to verify the mean deformation in abutments and simulated bone tissue around dental implants, with the use of strain gages, during framework screw retention, analyzing seven fabrication stages of the fixed partial denture. For this research, an experimental model based on homogeneous polyurethane with two external hexagon implants parallel to each other, provided with 5 mm height multi-unit abutments. For each, abutment surface received three equidistant strain gauges and the experimental block received upper surface four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The tests were performed screwing the specimens on the abutment using an electronic torque with 10 Ncm maximum force. The readings were made in seven moments, with abutment and polyurethane mean deformation, respectively: 1) control group: cobalt-chromium prefabricated machined cylinder (36,4µε e 87,5µε), 2) framework fabricated by 1-piece method in nickel-cobalt-chromium alloy (340,3µε e 131,4µε), 3) framework sectioned with space for welding (43,2µε e 66,6µε), 4) weld space filled with chemically activated acrylic resin (Duralay) (74µε e 86,8µε), 5) framework sectioned and soldered (280µε e 146,2µε), 6) framework welded and ceramic application (288,7µε e 151,1µε) and 7) framework concluded applying glaze, finishing and polishing (359,9µε e 197,8µε). The results showed the mean strain increase in abutment and polyurethane over fabrication stages, except that framework fabricated by 1-piece method reached high values close to finished prostheses. Thus, the welding procedure decreased strain levels in simulated bone tissue around dental implants, while ceramic and glaze application, finishing and polishing procedures, increased strain.


Asunto(s)
Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija , Poliuretanos/química , Resinas Acrílicas/química , Análisis de Varianza , Fenómenos Biomecánicos , Ensayo de Materiales , Ajuste de Prótesis , Torque
11.
Bauru; s.n; 2010. 159 p. ilus, tab, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: lil-599159

RESUMEN

O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não indicaram...


The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Poliuretanos/química , Análisis de Varianza , Aleaciones de Cromo/química , Ajuste de Prótesis
12.
Bauru; s.n; 2010. 159 p. ilus, tab, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-865625

RESUMEN

O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não ndicaram...


The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Poliuretanos/química , Análisis de Varianza , Aleaciones de Cromo/química , Ajuste de Prótesis
13.
Rev. odonto ciênc ; 23(4): 320-324, out.-dez. 2008. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-500143

RESUMEN

Purpose: The aim of this study was to evaluate the vertical marginal misfit of the metal framework of an implant-supported prosthesis. Methods: Ten frameworks were made of cobalt-chromium alloy (Co-Cr), simulating a three-element fixed prosthesis on two implants. Five frameworks were constructed using prefabricated cylinders, and the other five were constructed using calcinable cylinders. All frameworks were cast by the induction technique and laser-welded. Marginal misfit was measured by means of scanning electron microscopy with the frameworks subjected to the single-screw test. Twenty-five measurements of marginal fit were recorded per abutment and averaged for statistical analysis (ANOVA, alpha=0.05). Results: There was no statistically significant difference in marginal fit between the groups tested. The only difference found was when comparing the abutments with and without screw. Conclusion: It was concluded that there is no difference in marginal fit between frameworks cast in Co-Cr with calcinable and prefabricated cylinders using induction casting, laser-welding, and single-screw test.


Objetivo: O objetivo deste trabalho foi avaliar o desajuste marginal vertical de infra-estruturas metálicas de prótese fixa sobre implantes. Metodologia: Foram confeccionadas 10 infra-estruturas em liga de cobalto-cromo (Co-Cr), simulando uma prótese fixa de três elementos sobre dois implantes, com o auxílio de uma matriz metálica. Cinco infra-estruturas foram confeccionadas com cilindros pré-usinados. Outras cinco foram confeccionadas com cilindros calcináveis. Todas as infra-estruturas foram fundidas pela técnica de indução e soldadas a laser. As leituras do desajuste marginal foram realizadas através de microscopia eletrônica de varredura, utilizando a técnica do parafuso único, totalizando 25 medições em cada cilindro. As médias de desajuste marginal de cada cilindro foram utilizadas para a análise estatística (ANOVA, alfa=0,05). Resultados: Não houve diferença estatística no grau de desajuste marginal entre os grupos testados. Apenas houve diferença quando comparados os cilindros com e sem parafuso. Conclusão: Foi concluído que não há diferença de adaptação marginal entre as infra-estruturas fundidas em Co-Cr com cilindros calcináveis e pré-usinados, utilizando fundição por indução, soldagem a laser e teste do parafuso único.


Asunto(s)
Adaptación Marginal Dental , Implantes Dentales , Prótesis Dental de Soporte Implantado/efectos adversos
14.
Rev. dental press periodontia implantol ; 1(4): 78-87, out.-dez. 2007. ilus, tab
Artículo en Portugués | BBO - Odontología | ID: biblio-857688

RESUMEN

O sucesso da osseointegração está intimamente relacionado ao ajuste passivo entre os componentes utilizados e à precisão de adaptação da prótese instalada sobre os implantes. Quando os sistemas de implantes possuem um bom grau de padronização de usinagem existe a possibilidade de intercambiar seus componentes, de acordo com a necessidade, sem prejuízo para a conexão protética. O objetivo desta investigação foi avaliar o grau de liberdade entre os hexágonos dos implantes e abutments das empresas 3i, Implamed e Nobel Biocare, analisando: 1) as diferenças entre as medidas lineares das faces opostas dos implantes e abutments; 2) as diferenças entre as medidas lineares dos ângulos opostos dos implantes e abutments nos sistemas avaliados. A metodologia envolveu imagens obtidas através da microscopia eletrônica de varredura analisadas por um programa computadorizado específico. Através da análise de variância com nível de significância de 5% e teste de Tuckey para comparações múltiplas pôde-se observar que: 1) para as diferenças entre as medidas lineares das faces opostas dos hexágonos dos implantes e dos abutments houve diferença estatisticamente significante entre os grupos Nobel e Implamed, tendo o grupo Nobel os melhores resultados; 2) para as diferenças entre as medidas lineares dos ângulos opostos dos hexágonos dos implantes e dos abutments, o grupo Implamed diferiu dos demais, com os piores resultados.


The success of osseointegration is closely related to passive fit among the components employed and accurate fit of the implant-supported prosthesis. Implant systems with good machining standardization allow exchange of components according to the needs, without damage to the prosthetic connection. This study aimed to evaluate the degree of freedom among hexagons of implants and abutments fabricated by 3i, Implamed and Nobel Biocare, by analysis of: 1)differences among linear measurements of opposite aspects of implants and abutments 2) differences among linear measurements of opposite angles of implants and abutments in these systems. The metodology comprised analysis of scanning electron microscopy images by a specific computer software. Analysis of variance and the Tukey test for multiple comparisons at a significance level of 5% revealed the following: 1) there were statistically significant differences in linear measurements of opposite aspects of hexagons of implants and abutments between Nobel and implamed, with better results for the Nobel system; 2) concerning the differences among linear measurements of opposite angles of hexagons of implants and abutments, the Implamed system was different from the others, presenting the worst results.


Asunto(s)
Prótesis Dental de Soporte Implantado , Ensayo de Materiales , Análisis de Varianza , Microscopía Electrónica de Rastreo , Oseointegración , Prótesis e Implantes , Ajuste de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA