Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 592
Filtrar
1.
Diagnostics (Basel) ; 14(17)2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39272775

RESUMEN

Direct oral anticoagulants (DOACs) are increasingly used for the treatment of thrombosis. While inhibitors of factor IIa and factor Xa have shown effectiveness, the risk of bleeding remains a significant concern. Recently, direct factor XIa inhibitors-including asundexian and milvexian-have emerged as potential anticoagulation therapies, based on clinical observations that patients with factor XIa deficiencies seldom present with spontaneous bleeding tendencies. The interferences associated with DOACs in routine and specialised coagulation assays are well-described; however, the interferences associated with emerging FXIa inhibitors are largely uncharacterised. Here, we briefly report the impact of asundexian and milvexian in routine coagulation assays using in vitro plasma-based systems. Asundexian and milvexian induce concentration-dependent prolongations in APTT-based assays with curvilinear regressions, which may be suitable for the measurement of pharmacodynamic effects at peak levels ex vivo. We also report differential sensitivities of APTT-based assays-particularly at higher FXIa inhibitor concentrations-highlighting the clinical need for an extensive evaluation of interferences associated with FXIa inhibitors in coagulation assays.

2.
Clin Lab Med ; 44(3): 527-539, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39089756

RESUMEN

The term 'routine coagulation' typically applies to hemostasis tests routinely performed in hematology laboratories, often available 24/7, and potentially ordered urgently. These tests would comprise of the prothrombin time (PT), the PT converted to an international normalized ratio, the activated partial thromboplastin time (often called partial thromboplastin time in North American laboratories) and potentially the thrombin time, the D-dimer assay, and fibrinogen assays. Although other tests could feasibly be offered (testing feasible), there are good reasons for not including all of these other tests in all routine coagulation laboratories.


Asunto(s)
Tiempo de Protrombina , Humanos , Pruebas de Coagulación Sanguínea , Coagulación Sanguínea , Tiempo de Tromboplastina Parcial , Trastornos de la Coagulación Sanguínea/diagnóstico , Trastornos de la Coagulación Sanguínea/sangre , Productos de Degradación de Fibrina-Fibrinógeno/análisis
3.
Lab Med ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39213365

RESUMEN

BACKGROUND: Activated partial thromboplastin time (APTT) is susceptible to reagent composition. This study aimed to investigate a large number of specimens and determine the cause of discrepancies. METHOD: This study included 18,994 subjects who underwent coagulation tests at our hospital from May 2020 to December 2020. Measuring reagents included HemosIL SynthASil APTT (APTT-SS, Instrumentation Laboratory) and Coagpia APTT-N (APTT-N, Sekisui Medical). RESULTS: A total of 451 patients demonstrated APTT-N of >39 seconds and an APTT-N/SS ratio of >1.3. A C-reactive protein (CRP) level of ≥1.4 mg/L demonstrated a significant positive correlation, with a higher APTT-N/SS indicating higher CRP levels. All 28 subjects receiving no anticoagulants and who had remaining specimens underwent a cross-mixing test (CMT). Of them, 17 were suspected for lupus anticoagulant (LA) by both the waveform shape and the index of circulating anticoagulant (ICA) value, 6 by the ICA value, and 5 were difficult to determine. CONCLUSION: This study revealed that the APTT-N prolongation correlated with CRP degree and the transient involvement of LA in CMT results due to CRP. This study indicated various reactivities depending on the assay reagents used. Further testing is warranted if LA is suspected, considering the patient's background.

4.
Biomedicines ; 12(8)2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39200326

RESUMEN

Background: Subacute thyroiditis (SAT) is characterized by profound inflammation and fluctuations in thyroid hormones which may affect the hemostasis balance. This study investigates sex-specific associations between thyroid status, inflammation and hemostasis biomarkers in SAT. Methods: We included 52 patients (40 women and 12 men) treated with non-steroidal anti-inflammatory drugs (NSAID) or methylprednisolone (MPS). Free thyroxine (fT4), thyroid stimulating hormone, C-reactive protein, complete blood count and routine hemostasis parameters were assessed. Results: Both men and women were in hyperthyroid state and had comparable levels of inflammatory biomarkers. A shortened activated partial thromboplastin time (aPTT) was observed in 16.7% of the men and 10% of the women (p = 0.562), and a shortened prothrombin time (PT) was observed in 33% of the men and 12.5% of the women (p = 0.094). In men, aPTT positively correlated with fT4 (r = 0.627; p < 0.05), while PT positively correlated with leukocyte-based inflammatory indices in women (p < 0.05). NSAID-treated patients had lower aPTTs and platelet counts than those treated with MPS (p < 0.05). Principal component analysis extracted "proinflammatory", "prothrombotic" and "antithrombotic" factors, but the "proinflammatory" factor was the independent predictor of elevated fT4 in women (OR = 2.705; p = 0.036). Conclusions: Our data demonstrated sex-specific associations of thyroid status and inflammatory biomarkers with hemostasis parameters in SAT. Routine hemostasis screening tests may help in monitoring the changes in the hemostasis system over the course of SAT.

5.
Clin Chim Acta ; 562: 119887, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39059480

RESUMEN

BACKGROUND: Clot waveform analysis (CWA) reportedly enhances the interpretation of clotting time measurement. This study aimed to compare CWA between prothrombin time (PT) and activated partial thromboplastin time (APTT) assays for better understanding how to apply CWA for assessing effects of direct oral anticoagulants (DOACs). METHODS: Samples were prepared by spiking plasma with rivaroxaban, apixaban, edoxaban, or dabigatran. To compensate the influence of fibrinogen, CWA parameters were adjusted by unifying maximum changes in transmittance in clotting reaction curves detected by the optical system. RESULTS: Non-adjusted PT-CWA parameters unexpectedly rose at low drug concentrations but declined at high drug concentrations while adjusted PT-CWA parameters exhibited dose-dependent decrease. Both non-adjusted and adjusted APTT-CWA parameters showed dose-dependent decrease. Adjusted CWA parameters were applicable to Hill plot analysis. All DOACs exhibited Hill coefficients indicating positively cooperative effects regarding most adjusted PT-CWA parameters. Regarding adjusted APTT-CWA parameters, rivaroxaban, apixaban, and edoxaban exhibited Hill coefficients indicating no or negatively cooperative effects. The observed differences between PT-CWA and APTT-CWA suggested the implication of thrombin positive feedback in DOAC effects. CONCLUSION: The results revealed distinct features of DOAC effects in extrinsic and intrinsic pathways. To ascertain the clinical implication, further studies using clinical samples are needed.


Asunto(s)
Anticoagulantes , Tiempo de Protrombina , Humanos , Tiempo de Tromboplastina Parcial , Anticoagulantes/farmacología , Administración Oral , Coagulación Sanguínea/efectos de los fármacos
6.
Indian J Hematol Blood Transfus ; 40(3): 432-436, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39011243

RESUMEN

Monitoring of anticoagulant activity of unfractionated heparin (UFH) is primarily done with activated partial thromboplastin time (aPTT), which is affected by many factors. Anti-Xa assays are considered to overcome these factors and may provide a better method for monitoring patients on UFH with a narrow therapeutic range. This study aimed to compare the effectiveness of aPTT and anti-Xa assays in UFH monitoring. A prospective non-randomized study was carried out in two stages: first, the anti-Xa assay was standardized using kit instructions; each sample was then analyzed by both tests. The outcomes of the two assays were compared and assessed for agreement of maintaining therapeutic anticoagulant levels. These levels for anti-Xa assay were between 0.3 and 0.7 IU/ml, while it was 1.5-2.5 times the control for aPTT assay. Below this range was regarded as subtherapeutic, and above this as supratherapeutic. A total of 90 samples were tested and analyzed using both assays. Most of them (> 70%) were noted to be in subtherapeutic levels with both tests. The overall concordance was 73.3%, and the estimated kappa value was 0.483 (0.396-0.57). The correlation between aPTT and anti-Xa assay was 0.74 (p < 0.001). With anti-Xa levels in the therapeutic range, aPTT levels were in subtherapeutic in 60% and supratherapeutic in 13.3% cases. Although both the testing strategies had a good agreement and correlation, discordance was observed in interpretative values with anti-Xa levels in therapeutic range and aPTT levels in non-therapeutic range. Its clinical implications need to be evaluated further in future studies.

7.
Artículo en Inglés | MEDLINE | ID: mdl-39013708

RESUMEN

OBJECTIVES: There is extensive evidence to support the use of FIBTEM to identify hypofibrinogenemia during cardiac surgery, but less to support the use of EXTEM and INTEM clotting times (CTs) to identify other plasmatic coagulation factor deficiencies. The aim of the current study was to assess the diagnostic accuracy of EXTEM, INTEM, and HEPTEM CTs, using laboratory international normalized ratio (INR) and activated partial thromboplastin time (aPTT) as reference standards. DESIGN: This was a retrospective diagnostic accuracy study. SETTING: The work took place at a tertiary referral hospital. PARTICIPANTS: A total of 176 cardiac surgical patients were enrolled. INTERVENTIONS: INR, aPTT, ROTEM EXTEM, INTEM, and HEPTEM were measured post-heparin reversal after cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: Sensitivity, specificity, and positive (PPVs) and negative predictive values (NPVs) for EXTEM CT >80 seconds and HEPTEM CT >280 seconds to detect INR ≥2.0, and INTEM CT >205 seconds to detect aPTT ≥38.5 seconds were calculated for all patients and the subset with normal FIBTEM A5 (>6 mm). The prevalence of INR ≥2.0 was 13%. EXTEM CT >80 seconds had a sensitivity of 1.00, specificity of 0.25, PPV of 0.17, and NPV of 1.00. HEPTEM CT >280 seconds had a sensitivity of 0.91, specificity of 0.38, PPV of 0.18, and NPV of 0.97. INTEM CT >205 seconds had a sensitivity of 0.97, specificity of 0.11, PPV of 0.57, and NPV of 0.75 for aPTT ≥38.5 seconds. These values were similar for the subset of patients with normal FIBTEM A5. CONCLUSIONS: EXTEM CT >80 seconds and HEPTEM CT >280 seconds have high sensitivities and NPVs for INR >2.0, which would effectively "rule out" INR >2.0 as a cause for excessive bleeding. However, the low specificities and PPVs indicate they would be less effective in ruling it in. INTEM CT >205 seconds had low PPV and NPV in identifying aPTT >38.5 seconds.

8.
Ann Hematol ; 103(8): 3219-3227, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38935318

RESUMEN

INTRODUCTION: There are significant differences in the activated partial thromboplastin time (APTT) critical values reported in different studies, most of which does not make recommendations for any specific clear detection systems. The International Council for Standardization in Hematology (ICSH) recommends that APTT critical values be established based on the reagent type, coagulation factor sensitivity and heparin response. The objective of this study was to establish APTT critical values by using different reagents and based on single coagulation factor deficiencies. METHODS: The APTT values were determined in commercial endogenous coagulation factor-deficient plasma at concentrations of 1 IU/dL, 2 IU/dL, 5 IU/dL, 10 IU/dL, 20 IU/dL, and 30 IU/dL by using four assay systems. The retrospective collection of data from patients who lacked factor VIII (FVIII), FIX, or FXI alone was performed. Receiver operating characteristic (ROC) curves were constructed to assess the diagnostic accuracy of APTT for identifying patients with an endogenous coagulation factor activity < 5 IU/dL. RESULTS: The APTT values in the plasma samples with the same concentrations of endogenous coagulation factors were significantly different among the four assay systems (P < 0.001). The suggested critical values of APTT were 40.0 s for Sysmex CS5100 (Actin FSL), 58.0 s for Sysmex CS5100 (Actin), 51.8 s for STA-R Evolution (STA-PTTA), and 64.8 s for ACL TOP 700 (HemosIL SynthasIL). On the basis of the ROC curve, the optimal threshold values for APTT (STA-PTTA) were 55.8 s in patients with a simple deficiency of FVIII (sensitivity = 100%, specificity = 85.7%, area under the ROC curve (AUC) = 0.982), 54.3 s in patients with a simple deficiency of FIX (sensitivity = 100%, specificity = 92.9%, AUC = 0.986), and 71.7 s in patients with a simple deficiency of FXI (sensitivity = 100%, specificity = 94.1%, AUC = 0.992), which were closer (difference of 0.6-2.5 s) to the cutoff points for commercial plasma at equal factor levels. CONCLUSIONS: APTT critical values need to be established for different reagents based on the presence of a single coagulation factor deficiency.


Asunto(s)
Factores de Coagulación Sanguínea , Humanos , Tiempo de Tromboplastina Parcial , Estudios Retrospectivos , Factores de Coagulación Sanguínea/análisis , Femenino , Masculino , Trastornos de las Proteínas de Coagulación/sangre , Trastornos de las Proteínas de Coagulación/diagnóstico , Curva ROC , Pruebas de Coagulación Sanguínea/métodos , Pruebas de Coagulación Sanguínea/normas , Indicadores y Reactivos
9.
Artículo en Inglés | MEDLINE | ID: mdl-38874122

RESUMEN

OBJECTIVE: To describe and compare prothrombin time (PT), activated partial thromboplastin time (aPTT), thromboelastography (TEG), HCT, and platelet count measurements in a hemorrhage/over-resuscitation model. DESIGN: Randomized crossover study. SETTING: University teaching hospital. ANIMALS: Six cats. INTERVENTIONS: Anesthetized cats underwent 3 treatments at 2-month intervals. The treatments were as follows: NHR-no controlled hemorrhage and sham resuscitation; LRS-controlled hemorrhage and lactated Ringer's solution (LRS) for resuscitation; and Voluven-controlled hemorrhage and 6% tetrastarch 130/0.4 for resuscitation. The LRS and Voluven were administered at 60 and 20 mL/kg/h, respectively, for 120 minutes. Blood samples were drawn for PT, aPTT, TEG, HCT, and platelet count measurements at a healthy check (T - 7d), after controlled hemorrhage (T0), at 60 and 120 minutes of resuscitation (T60 and T120), and at 24 hours after completion of resuscitation (T24h). Data were analyzed using a general linear mixed model approach (significance was P < 0.05). MEASUREMENTS AND MAIN RESULTS: Total median blood loss (controlled hemorrhage and blood sampling from T0 to T120) at T120 was 11.4, 31.0, and 30.8 mL/kg for NHR, LRS, and Voluven, respectively. PT and aPTT during LRS and Voluven were prolonged at T60 and T120 compared to NHR (P < 0.001). On TEG, the reaction time, kinetic time, and alpha-angle were within reference intervals for cats at all time points in all treatments, while maximum amplitude was less than the reference interval (40 mm) at T0, T60, and T120 during Voluven and at T60 and T120 during LRS compared to NHR (both P < 0.001). The HCT and platelet count were significantly lower at T60 and T120 during LRS and Voluven compared to NHR (P < 0.001). CONCLUSIONS: Hypocoagulopathy was observed during hemorrhage and liberal fluid resuscitation. Prolongation of PT and aPPT and decreased clot strength may have been caused by hemodilution and platelet loss.


Asunto(s)
Estudios Cruzados , Tiempo de Protrombina , Resucitación , Lactato de Ringer , Tromboelastografía , Animales , Gatos , Tromboelastografía/veterinaria , Tromboelastografía/métodos , Lactato de Ringer/administración & dosificación , Lactato de Ringer/farmacología , Recuento de Plaquetas/veterinaria , Tiempo de Protrombina/veterinaria , Hematócrito/veterinaria , Tiempo de Tromboplastina Parcial/veterinaria , Resucitación/veterinaria , Resucitación/métodos , Hemorragia/veterinaria , Hemorragia/sangre , Enfermedades de los Gatos/sangre , Derivados de Hidroxietil Almidón/farmacología , Derivados de Hidroxietil Almidón/administración & dosificación , Masculino , Femenino , Gelatina/administración & dosificación , Gelatina/farmacología , Succinatos
10.
Haemophilia ; 30(4): 1003-1009, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38924261

RESUMEN

INTRODUCTION: Diagnosing hemophilia B (HB) carrier status is important to manage bleeding in carriers and to prevent bleeding in potential offspring. Without a family history of hemophilia, diagnosing HB carrier status is challenging. Genetic testing is the gold-standard, however it is reserved for individuals with a high suspicion of carrier status. AIMS: To describe the distribution of activated partial thromboplastin time (aPTT) and factor IX coagulant (FIX:C) levels in HB carriers and assess the ratio of FIX:C to other Vitamin K dependent factors (FII:C, FVII:C, FX:C) as an indicator of HB carrier status. METHODS: In this retrospective, single-centre cohort study, subjects were included if they were obligate or genetically proven HB carriers. Distributions of aPTT and FIX:C were described and the relationship between FIX:C levels in carriers and severity of familial HB was analysed. Ratios of FIX:C to FII:C, FVII:C, FX:C were calculated. RESULTS: Seventy-two female HB carriers (median age: 34 years; IQR 24-43) were included. Median aPTT and FIX:C levels were 33.0 s [IQR 30.0-37.0] and 57 IU/dL [IQR 43-74]. Fifteen carriers (21%) had mild HB (FIX:C levels of 10-40 IU/dL). FIX:C levels trended higher in carriers of mild HB versus carriers of moderate/severe HB. In six carriers, the median ratio of FIX:C to other Vitamin K dependent factors was 0.44, with 92% of ratios being ≤ 0.75. CONCLUSION: aPTT and FIX:C levels were unreliable in diagnosing HB carrier status. A low ratio of FIX:C to other Vitamin K dependent factors may be a useful marker of HB carrier status.


Asunto(s)
Factor IX , Hemofilia B , Vitamina K , Humanos , Hemofilia B/sangre , Hemofilia B/diagnóstico , Hemofilia B/genética , Factor IX/metabolismo , Factor IX/genética , Factor IX/análisis , Femenino , Adulto , Tiempo de Tromboplastina Parcial/métodos , Estudios Retrospectivos , Adulto Joven , Heterocigoto , Estudios de Cohortes , Masculino
11.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 32(3): 805-810, 2024 Jun.
Artículo en Chino | MEDLINE | ID: mdl-38926971

RESUMEN

OBJECTIVE: To evaluate the clinical and prognostic value of prothrombin time (PT) and activated partial thromboplastin time (APTT) in newly diagnosed patients with multiple myeloma (MM). METHODS: The clinical data of 116 newly diagnosed MM patients in the Second Hospital and Third Hospital of Shanxi Medical University from October 2014 to March 2022 were analyzed retrospectively, and the patients were divided into two groups: normal PT and APTT group and prolonged PT or APTT group. The differences in sex, age, classification, staging, bleeding events, laboratory indicators [including hemoglobin (Hb), platelet count (PLT), serum calcium, serum albumin (ALB), lactate dehydrogenase (LDH), serum creatinine and ß2-microglobulin], and cytogenetic characteristics between the two groups of patients were compared. The effect of prolonged PT or APTT on survival of patients with MM was analyzed. RESULTS: Compared with patients in normal PT and APTT group, patients in prolonged PT or APTT group were more likely to experience bleeding events (χ2=5.087, P =0.024), with lower ALB levels (χ2=4.962, P =0.026) and PLT levels (χ2=4.309, P =0.038), and higher serum calcium levels (χ2=5.056, P =0.025). The positive rates of del17p, del13q and 1q21+ in prolonged PT or APTT group were higher than those in normal PT and APTT group, but the difference was not statistically significant (P >0.05). K-M survival analysis showed that the prolonged PT or APTT group had a shorter median progression-free survival (PFS) (P =0.032) and overall survival (OS) (P =0.032). Multivariate Cox analysis showed that prolonged PT or APTT (HR=2.116, 95%CI :1.025-4.372, P =0.043) and age ≥65 years (HR=2.403, 95%CI : 1.195-4.836, P =0.014) were independent risk factor for OS in newly diagnosed MM patients. However, prolonged PT or APTT had no significant effect on PFS of newly diagnosed MM patients (HR=1.162, 95%CI : 0.666-2.026, P =0.597). CONCLUSION: Newly diagnosed MM patients with prolonged PT or APTT have worse clinical indicators, shorter PFS and OS. Prolonged PT or APTT is an independent risk factor for OS in MM patients.


Asunto(s)
Mieloma Múltiple , Tiempo de Protrombina , Humanos , Mieloma Múltiple/sangre , Mieloma Múltiple/diagnóstico , Tiempo de Tromboplastina Parcial , Pronóstico , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad
12.
Materials (Basel) ; 17(12)2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38930247

RESUMEN

The paper presents the study concerning the preparation and physio-chemical and biological properties of wool-copper (WO-Cu) materials obtained by the sputter deposition of copper onto the wool fibers. The WO-Cu material was subjected to physio-chemical and biological investigations. The physio-chemical investigations included the elemental analysis of materials (C, N, O, S, and Cu), their microscopic analysis, and surface properties analysis (specific surface area and total pore volume). The biological investigations consisted of the antimicrobial activity tests of the WO-Cu materials against colonies of Gram-positive (Staphylococcus aureus) bacteria, Gram-negative (Escherichia coli) bacteria, and fungal mold species (Chaetomium globosum). Biochemical-hematological tests included the evaluation of the activated partial thromboplastin time and pro-thrombin time. The tested wool-copper demonstrated the ability to interact with the DNA in a time-dependent manner. These interactions led to the DNA's breaking and degradation. The antimicrobial and antifungal activities of the WO-Cu materials suggest a potential application as an antibacterial/antifungal material. Wool-copper materials may be also used as customized materials where the blood coagulation process could be well controlled through the appropriate copper content.

13.
J Infect Dev Ctries ; 18(5): 666-671, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38865388

RESUMEN

INTRODUCTION: Coronavirus 2019 symptoms include coagulopathy and thromboembolic risk. Using one parameter to diagnose coagulopathy has little predictive value. OBJECTIVE: This study will examine if D-dimer and APTT testing can predict COVID-19 severity and aid triage and manage patients. METHODS: 214 COVID-19 patients were enrolled and classified into two categories based on their respiratory manifestations; mild (126 cases) and severe (88 cases). Patient data regarding age, gender, D-Dimer level, and APTT level were collected. When both D-Dimer and APTT levels were abnormal, in this study, the patient was considered to have a coagulation disorder. Indicators of coagulation in the COVID-19 patients were collected and compared between the two groups. Chi-square (χ2) tests were used to determine the significant differences between coagulation disorders in the two groups. RESULTS: Our findings showed that patients with coagulopathies were more likely to belong to the severe group. Within the two groups of patients, the rate of coagulation disorders was as follows: mild = 8.8 % within coagulation disorders, 4.8% within the two Groups; severe = 91.2 % within coagulation disorders, 77.8 % within the two Groups. There was a statistically significant relationship between coagulation disorder and severe COVID-19 patients compared to mild patients (p < 0.05). CONCLUSIONS: Coagulation disorders are more likely to occur in severe COVID-19 patients. D-Dimer and APTT tests are significant indicators for predicting COVID-19 severity. Our research found an abnormal pattern of coagulation disorders and COVID-19 severity that should be considered in the COVID-19 treatment protocol.


Asunto(s)
Trastornos de la Coagulación Sanguínea , COVID-19 , Productos de Degradación de Fibrina-Fibrinógeno , Valor Predictivo de las Pruebas , Humanos , COVID-19/sangre , COVID-19/diagnóstico , COVID-19/complicaciones , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Masculino , Femenino , Persona de Mediana Edad , Tiempo de Tromboplastina Parcial , Trastornos de la Coagulación Sanguínea/diagnóstico , Trastornos de la Coagulación Sanguínea/sangre , Adulto , Anciano , Índice de Severidad de la Enfermedad , SARS-CoV-2/aislamiento & purificación
14.
ESC Heart Fail ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38725133

RESUMEN

AIMS: It is unclear whether activated partial thromboplastin time (aPTT) or anti-Xa is more accurate for monitoring heparin anticoagulation in mechanical circulatory support (MCS) patients. This study investigates the relationship between aPTT and anti-Xa in MCS patients and identifies predictors of discordance. METHODS AND RESULTS: aPTT and anti-Xa were simultaneously measured in a prospective cohort of MCS patients receiving unfractionated heparin at a tertiary academic medical centre. Therapeutic aPTT and anti-Xa levels were 60-100 s and 0.3-0.7 IU/mL, respectively, and concordance was defined as both levels being subtherapeutic, therapeutic, or supratherapeutic. To identify predictors of discordance, both a machine learning random forest model and a multivariate regression model were applied to patient demographics, device type, and 14 laboratory variables; 23 001 pairs of simultaneously measured aPTT/anti-Xa were collected from 699 MCS patients. aPTT and anti-Xa were concordant in 35.5% of paired observations and discordant in 64.5% (aPTT > antiXa 61.5%; aPTT < antiXa 3.0%). Discordance with a high aPTT relative to anti-Xa (aPTT > antiXa) was associated with high INR, eGFR, and total bilirubin, as well as low platelets, haemoglobin, pre-albumin, white blood cell count, and haptoglobin. Total artificial heart and durable ventricular assist devices were more likely to be associated with aPTT > anti-Xa than temporary MCS devices. CONCLUSIONS: aPTT and anti-Xa were frequently discordant in MCS patients receiving heparin anticoagulation. Clinical conditions common in MCS patients such as concurrent warfarin use, malnutrition, haemolysis, and thrombocytopenia, as well as durable type of MCS devices were associated with a high aPTT relative to anti-Xa.

15.
Perfusion ; : 2676591241253474, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38739366

RESUMEN

INTRODUCTION: Bleeding and thrombotic complications are common in extracorporeal membrane oxygenation (ECMO) patients and are associated with increased mortality and morbidity. The optimal anticoagulation monitoring protocol in these patients is unknown. This study aims to compare the incidence of thrombotic and hemorrhagic complications before and after a protocol change. In addition, the association between hemostatic complications, coagulation tests and risk factors is evaluated. METHODS: This is a retrospective single center cohort study of adult ECMO patients. We collected demographics, ECMO parameters and coagulation test results. Outcomes of the aPTT guided and multimodal protocol, including aPTT, anti-Xa assay and rotational thromboelastometry were compared and the association between coagulation tests, risk factors and hemostatic complications was determined using a logistic regression analysis for repeated measurements. RESULTS: In total, 250 patients were included, 138 in the aPTT protocol and 112 in the multimodal protocol. The incidence of thrombosis (aPTT: 14%; multimodal: 12%) and bleeding (aPTT: 36%; multimodal: 40%), did not significantly differ between protocols. In the aPTT guided protocol, the aPTT was associated with thrombosis (Odds Ratio [OR] 1.015; 95% confidence interval [CI] 1.004-1.027). In both protocols, surgical interventions were risk factors for bleeding and thrombotic complications (aPTT: OR 93.2, CI 39.9-217.6; multimodal OR 17.5, CI 6.5-46.9). DISCUSSION: The incidence of hemostatic complications was similar between both protocols and surgical interventions were a risk factor for hemostatic complications. Results from this study help to elucidate the role of coagulation tests and risk factors in predicting hemostatic complications in patients undergoing ECMO support.

16.
Diagnosis (Berl) ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38696342

RESUMEN

OBJECTIVES: It has been recognized that shortened activated partial thromboplastin time (aPTT) may be caused by various preanalytical conditions. As coagulation Factor VIII is included in the in vitro intrinsic coagulation cascade measured by aPTT, we hypothesized that the shortened aPTT could be a result of elevated FVIII activity. We aimed to inspect the connection of elevated FVIII with shortened aPTT, and the possible effect inflammation has on routine laboratory parameters. METHODS: 40 patients from various hospital departments with aPTT measurement below the lower limit of the reference interval (<23.0 s) were included in the study. To compare the obtained results with aPTT measurements in the non-inflammatory state, samples from 25 volunteers (laboratory personnel) were collected. White blood cell count, C-reactive protein, aPTT, and FVIII values were measured in the control group. RESULTS: Only two samples among 40 patients with shortened aPTT (5 %) were clotted. Out of the remaining 38, 26 had FVIII activity above 150 % (upper limit of a reference interval), median value of 194 % (IQR: 143-243 %). Seven samples in the control group had shortened aPTT results (36 %). However, all coagulation samples were clot and hemolysis-free. Multiple regression identified only FVIII activity as an independent variable in predicting aPTT values (p=0.001). CONCLUSIONS: Our results support the thesis that shortened aPTT is rarely a consequence of preanalytical problems. Elevated FVIII activity causes shortened aPTT, not only in the inflammatory state but also in individuals with concentration of inflammatory markers within reference intervals.

17.
18.
BMC Pregnancy Childbirth ; 24(1): 354, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741046

RESUMEN

BACKGROUND: Preeclampsia (PE), an obstetric disorder, remains one of the leading causes of maternal and infant mortality worldwide. In individuals with PE, the coagulation-fibrinolytic system is believed to be among the most significantly impacted systems due to maternal inflammatory responses and immune dysfunction. Therefore, this systematic review and meta-analysis aimed to assess the association of prothrombin time (PT), thrombin time (TT) and activated partial thromboplastin time (APTT) levels with preeclampsia. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA guidelines. Articles relevant to the study, published from July 26, 2013, to July 26, 2023, were systematically searched across various databases including PubMed, Scopus, Embase, and Hinari. The methodological quality of the articles was evaluated using the Joanna Briggs Institute critical appraisal checklist. Utilizing Stata version 14.0, a random-effects model was employed to estimate the pooled standardized mean difference (SMD) along with the respective 95% CIs. The I2 statistics and Cochrane Q test were utilized to assess heterogeneity, while subgroup analyses were performed to explore its sources. Furthermore, Egger's regression test and funnel plot were employed to assess publication bias among the included studies. RESULTS: A total of 30 articles, involving 5,964 individuals (2,883 with PE and 3,081 as normotensive pregnant mothers), were included in this study. The overall pooled SMD for PT, APTT, and TT between PE and normotensive pregnant mothers were 0.97 (95% CI: 0.65-1.29, p < 0.001), 1.05 (95% CI: 0.74-1.36, p < 0.001), and 0.30 (95% CI: -0.08-0.69, p = 0.11), respectively. The pooled SMD indicates a significant increase in PT and APTT levels among PE patients compared to normotensive pregnant mothers, while the increase in TT levels among PE patients was not statistically significant. CONCLUSIONS: The meta-analysis underscores the association between PE and prolonged PT and APTT. This suggests that evaluating coagulation parameters like PT, APTT, and TT in pregnant women could offer easily accessible and cost-effective clinical indicators for assessing PE. However, multicenter longitudinal studies are needed to evaluate their effectiveness across various gestational weeks of pregnancy.


Asunto(s)
Preeclampsia , Tiempo de Protrombina , Humanos , Embarazo , Femenino , Preeclampsia/sangre , Tiempo de Tromboplastina Parcial , Tiempo de Trombina , Coagulación Sanguínea
19.
JA Clin Rep ; 10(1): 30, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38713343

RESUMEN

BACKGROUND: Isolated prolongation of activated partial thromboplastin time (APTT) has various causes including inheritable bleeding disorders, and has medical significance as it can lead to the cancelation of surgery. However, even an emergency surgery can be conducted in a patient presenting with severe APTT prolongation, provided careful evaluation and appropriate measures are taken. Hence, the identification of the underlying etiology of the prolonged APTT is crucial. To date, little evidence exists regarding the prevalence of isolated APTT prolongation in Japanese patients undergoing surgery. Herein, we aimed to clarify the prevalence of isolated prolongation of APTT in the preoperative setting and to identify the reasons underlying isolated, severely prolonged APTT. METHODS: Preoperative coagulation data of all elective and emergent patients who presented to the anesthetic department between January 1, 2020, and June 30, 2023, were retrospectively collected. Isolated prolongation of APTT was defined as an APTT ≥ 37 s with an international normalized ratio of prothrombin time < 1.2. The underlying etiology of the patient with isolated, severely prolonged APTT (≥ 46 s) was investigated, and canceled surgical procedures in relation to the isolated APTT prolongation were searched. RESULTS: Overall, 10,684 measurements from 9413 patients were included, of which 725 (6.8%) were identified as having isolated APTT prolongation. The reasons for the severely prolonged APTT (n = 60) were miscellaneous, with the most frequently detected etiology being antiphospholipid antibody positivity. Preoperative isolated APTT prolongation contributed to the cancellation of surgery in elective five cases. CONCLUSIONS: We clarified the prevalence of preoperative isolated prolongation of APTT. The presence of antiphospholipid antibody was the most frequently detected etiology of the patient with isolated, severely prolonged APTT. The present study provides an important dataset regarding the isolated prolongation of APTT in East Asian patients undergoing surgery.

20.
Int J Mol Sci ; 25(7)2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38612796

RESUMEN

The development of novel anticoagulants requires a comprehensive investigational approach that is capable of characterizing different aspects of antithrombotic activity. The necessary experiments include both in vitro assays and studies on animal models. The required in vivo approaches include the assessment of pharmacokinetic and pharmacodynamic profiles and studies of hemorrhagic and antithrombotic effects. Comparison of anticoagulants with different mechanisms of action and administration types requires unification of the experiment scheme and its adaptation to existing laboratory conditions. The rodent thrombosis models in combination with the assessment of hemostasis parameters and hematological analysis are the classic methods for conducting preclinical studies. We report an approach for the comparative study of the activity of different anticoagulants in vivo, including the investigation of pharmacodynamics and the assessment of hemorrhagic effects (tail-cut bleeding model) and pathological thrombus formation (inferior vena cava stenosis model of venous thrombosis). The reproducibility and uniformity of our set of experiments were illustrated on unfractionated heparin and dabigatran etexilate (the most common pharmaceuticals in antithrombic therapy) as comparator drugs and an experimental drug variegin from the tick Amblyomma variegatum. Variegin is notorious since it is a potential analogue of bivalirudin (Angiomax, Novartis AG, Basel, Switzerland), which is now being actively introduced into antithrombotic therapy.


Asunto(s)
Anticoagulantes , Heparina , Animales , Preparaciones Farmacéuticas , Anticoagulantes/farmacología , Anticoagulantes/uso terapéutico , Heparina/farmacología , Heparina/uso terapéutico , Fibrinolíticos/farmacología , Fibrinolíticos/uso terapéutico , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA