1.
Sensors (Basel) ; 23(12)2023 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-37420830

RESUMEN

We used an ultrasensitive, broadband optomechanical ultrasound sensor to study the acoustic signals produced by pressurized nitrogen escaping from a variety of small syringes. Harmonically related jet tones extending into the MHz region were observed for a certain range of flow (i.e., Reynolds number), which is in qualitative agreement with historical studies on gas jets emitted from pipes and orifices of much larger dimensions. For higher turbulent flow rates, we observed broadband ultrasonic emission in the ~0-5 MHz range, which was likely limited on the upper end due to attenuation in air. These observations are made possible by the broadband, ultrasensitive response (for air-coupled ultrasound) of our optomechanical devices. Aside from being of theoretical interest, our results could have practical implications for the non-contact monitoring and detection of early-stage leaks in pressured fluid systems.


Asunto(s)
Jeringas , Ultrasonido , Ultrasonografía
2.
Quant Imaging Med Surg ; 12(2): 1608-1631, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35111652

RESUMEN

Optical ultrasound sensors have been increasingly employed in biomedical diagnosis and photoacoustic imaging (PAI) due to high sensitivity and resolution. PAI could visualize the distribution of ultrasound excited by laser pulses in biological tissues. The information of tissues is detected by ultrasound sensors in order to reconstruct structural images. However, traditional ultrasound transducers are made of piezoelectric films that lose sensitivity quadratically with the size reduction. In addition, the influence of electromagnetic interference limits further applications of traditional ultrasound transducers. Therefore, optical ultrasound sensors are developed to overcome these shortcomings. In this review, optical ultrasound sensors are classified into resonant and non-resonant ones in view of physical principles. The principles and basic parameters of sensors are introduced in detail. Moreover, the state of the art of optical ultrasound sensors and applications in PAI are also presented. Furthermore, the merits and drawbacks of sensors based on resonance and non-resonance are discussed in perspectives. We believe this review could provide researchers with a better understanding of the current status of optical ultrasound sensors and biomedical applications.

3.
J Biomed Opt ; 26(6)2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34196136

RESUMEN

SIGNIFICANCE: Acoustically detecting the rich optical absorption contrast in biological tissues, photoacoustic tomography (PAT) seamlessly bridges the functional and molecular sensitivity of optical excitation with the deep penetration and high scalability of ultrasound detection. As a result of continuous technological innovations and commercial development, PAT has been playing an increasingly important role in life sciences and patient care, including functional brain imaging, smart drug delivery, early cancer diagnosis, and interventional therapy guidance. AIM: Built on our 2016 tutorial article that focused on the principles and implementations of PAT, this perspective aims to provide an update on the exciting technical advances in PAT. APPROACH: This perspective focuses on the recent PAT innovations in volumetric deep-tissue imaging, high-speed wide-field microscopic imaging, high-sensitivity optical ultrasound detection, and machine-learning enhanced image reconstruction and data processing. Representative applications are introduced to demonstrate these enabling technical breakthroughs in biomedical research. CONCLUSIONS: We conclude the perspective by discussing the future development of PAT technologies.


Asunto(s)
Técnicas Fotoacústicas , Tomografía , Sistemas de Liberación de Medicamentos , Humanos , Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X
4.
Micromachines (Basel) ; 11(7)2020 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-32708869

RESUMEN

Ultrasound detection is one of the major components of photoacoustic imaging systems. Advancement in ultrasound transducer technology has a significant impact on the translation of photoacoustic imaging to the clinic. Here, we present an overview on various ultrasound transducer technologies including conventional piezoelectric and micromachined transducers, as well as optical ultrasound detection technology. We explain the core components of each technology, their working principle, and describe their manufacturing process. We then quantitatively compare their performance when they are used in the receive mode of a photoacoustic imaging system.

5.
J Biomed Opt ; 23(10): 1-12, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30369105

RESUMEN

In recent times, there has been extensive research on fiber-optic imaging devices in order to enable imaging/sensing at a size scale inaccessible to other modalities. The design for fabrication of a highly sensitive fiber-optic ultrasound detector is proposed. The transducer employs a polymer Fabry-Pérot resonator for ultrasound detection. To enhance acoustic sensitivity, a method is proposed for fabricating a self-aligned polymer waveguide within the cavity to improve the resonator quality factor (Q-factor). Simulation studies were conducted to evaluate feasibility and quantify the improvement in Q-factor for different transducer configurations. Results show that with dielectric mirrors and a waveguide, Q-factor can approach the order of 10,000. Additional simulation studies are presented to analyze the effect of cavity shape on the device performance, drawing out the importance of a flat mirror for waveguided devices. Subsequently, results from optical testing of the first iteration of fabricated devices are presented, highlighting the main drawback of this method-the nonideal shape of the waveguiding pillar. Finally, initial results from the second iteration of devices that overcome this drawback are presented, demonstrating the feasibility of creating straight self-aligned polymer waveguides on gold-coated fibers, followed by a discussion on the implications of this work and future steps.


Asunto(s)
Diseño de Equipo/métodos , Interferometría/instrumentación , Ultrasonografía Intervencional/instrumentación , Tecnología de Fibra Óptica/instrumentación
6.
Photoacoustics ; 5: 1-9, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28239552

RESUMEN

We report on a novel imaging system for large depth of field photoacoustic scanning macroscopy. Instead of commonly used piezoelectric transducers, fiber-optic based ultrasound detection is applied. The optical fibers are shaped into rings and mainly receive ultrasonic signals stemming from the ring symmetry axes. Four concentric fiber-optic rings with varying diameters are used in order to increase the image quality. Imaging artifacts, originating from the off-axis sensitivity of the rings, are reduced by coherence weighting. We discuss the working principle of the system and present experimental results on tissue mimicking phantoms. The lateral resolution is estimated to be below 200 µm at a depth of 1.5 cm and below 230 µm at a depth of 4.5 cm. The minimum detectable pressure is in the order of 3 Pa. The introduced method has the potential to provide larger imaging depths than acoustic resolution photoacoustic microscopy and an imaging resolution similar to that of photoacoustic computed tomography.

7.
Photoacoustics ; 3(4): 143-150, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31467845

RESUMEN

Three-dimensional photoacoustic microscopy (PAM) has gained considerable attention within the biomedical imaging community during the past decade. Detecting laser-induced photoacoustic waves by optical sensing techniques facilitates the idea of all-optical PAM (AOPAM), which is of particular interest as it provides unique advantages for achieving high spatial resolution using miniaturized embodiments of the imaging system. The review presents the technology aspects of optical-sensing techniques for ultrasound detection, such as those based on optical resonators, as well as system developments of all-optical photoacoustic systems including PAM, photoacoustic endoscopy, and multi-modality microscopy. The progress of different AOPAM systems and their representative applications are summarized.