Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39066744

RESUMEN

BACKGROUND: New postprocessing software facilitates 3-dimensional (3D) echocardiographic determination of mitral annular (MA) and neo-left ventricular outflow tract (neo-LVOT) dimensions in patients undergoing transcatheter mitral valve replacement (TMVR). OBJECTIVES: This study aims to test the accuracy of 3D echocardiographic analysis as compared to baseline computed tomography (CT). METHODS: A total of 105 consecutive patients who underwent TMVR at 2 tertiary care centers between October 2017 and May 2023 were retrospectively included. A virtual valve was projected in both baseline CT and 3D transesophageal echocardiography (TEE) using dedicated software. MA dimensions were measured in baseline images and neo-LVOT dimensions were measured in baseline and postprocedural images. All measurements were compared to baseline CT as a reference. The predicted neo-LVOT area was correlated with postprocedural peak LVOT gradients. RESULTS: There was no significant bias in baseline neo-LVOT prediction between both imaging modalities. TEE significantly underestimated MA area, perimeter, and medial-lateral dimension compared to CT. Both modalities significantly underestimated the actual neo-LVOT area (mean bias pre/post TEE: 25.6 mm2, limit of agreement: -92.2 mm2 to 143.3 mm2; P < 0.001; mean bias pre/post CT: 28.3 mm2, limit of agreement: -65.8 mm2 to 122.4 mm2; P = 0.046), driven by neo-LVOT underestimation in the group treated with dedicated mitral valve bioprosthesis. Both CT- and TEE-predicted-neo-LVOT areas exhibited an inverse correlation with postprocedural LVOT gradients (r2 = 0.481; P < 0.001 for TEE and r2 = 0.401; P < 0.001 for CT). CONCLUSIONS: TEE-derived analysis provides comparable results with CT-derived metrics in predicting the neo-LVOT area and peak gradient after TMVR.

2.
Catheter Cardiovasc Interv ; 102(7): 1341-1347, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37855165

RESUMEN

BACKGROUND: Alcohol septal ablation (ASA) has been shown to increase the neo-left ventricular outflow tract (LVOT) area before transcatheter mitral valve replacement (TMVR) but there is little literature on its success and use with dedicated devices. AIMS: To describe our experience with preemptive ASA to increase the predicted neo-LVOT area and its utility with both dedicated TMVR devices and balloon-expandable valves. METHODS: All patients who underwent ASA for TMVR candidacy in our center between May 2018 and October 2022 and had computed tomography (CT) scans done before and after ASA were included. Each CT was assessed for the minimum predicted neo-LVOT area at end-systole, using a virtual valve of the desired TMVR device for each patient. The primary outcome was an increase in the predicted neo-LVOT area after ASA that was deemed sufficient for safe implantation of the desired TMVR device. The secondary outcome was the absence of acute LVOT obstruction after TMVR. RESULTS: A total of 12 patients underwent ASA and all but 1 (n = 11, 91.6%) achieved the primary outcome of having sufficient predicted neo-LVOT area to proceed with TMVR. The mean increase in neo-LVOT area after ASA was 126 ± 64 mm2 (median 119.5, interquartile range: 65.0-163.5 mm2 ). Two patients (16.7%) required a permanent pacemaker after ASA. Nine patients went on and underwent TMVR with their respective devices and none had LVOT obstruction after the procedure. Among the remaining three patients, one had insufficient neo-LVOT clearance after ASA, one had unrelated mortality before TMVR, and one had advanced heart failure before TMVR. CONCLUSION: In appropriately selected patients and at centers experienced with ASA, preemptive ASA can achieve sufficient neo-LVOT clearance for TMVR with a variety of devices in approximately 90% of patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Factores de Riesgo , Cateterismo Cardíaco , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA