Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Front Neurosci ; 17: 1293017, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38116068

RESUMEN

Introduction: Beneficial effects have been observed for mechanical vibration stimulation (MVS), which are mainly attributed to tonic vibration reflex (TVR). TVR is reported to elicit synchronized motor unit activation during locally applied vibration. Similar effects are also observed in a novel vibration system referred to as functional force stimulation (FFS). However, the manifestation of TVR in FFS is doubted due to the use of global electromyography (EMG) features in previous analysis. Our study aims to investigate the effects of FFS on motor unit discharge patterns of the human biceps brachii by analyzing the motor unit spike trains decoded from the high-density surface EMG. Methods: Eighteen healthy subjects volunteered in FFS training with different amplitudes and frequencies. One hundred and twenty-eight channel surface EMG was recorded from the biceps brachii and then decoded after motion-artifact removal. The discharge timings were extracted and the coherence between different motor unit spike trains was calculated to quantify synchronized activation. Results and discussion: Significant synchronization within the vibration cycle and/or its integer multiples is observed for all FFS trials, which increases with increased FFS amplitude. Our results reveal the basic physiological mechanism involved in FFS, providing a theoretical foundation for analyzing and introducing FFS into clinical rehabilitation programs.

2.
Biosensors (Basel) ; 11(10)2021 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-34677312

RESUMEN

Surface electromyography (EMG) recorded by a linear or 2-dimensional electrode array can be used to estimate the location of muscle innervation zones (IZ). There are various neurophysiological factors that may influence surface EMG and thus potentially compromise muscle IZ estimation. The objective of this study was to evaluate how surface-EMG-based IZ estimation might be affected by different factors, including varying degrees of motor unit (MU) synchronization in the case of single or double IZs. The study was performed by implementing a model simulating surface EMG activity. Three different MU synchronization conditions were simulated, namely no synchronization, medium level synchronization, and complete synchronization analog to M wave. Surface EMG signals recorded by a 2-dimensional electrode array were simulated from a muscle with single and double IZs, respectively. For each situation, the IZ was estimated from surface EMG and compared with the one used in the model for performance evaluation. For the muscle with only one IZ, the estimated IZ location from surface EMG was consistent with the one used in the model for all the three MU synchronization conditions. For the muscle with double IZs, at least one IZ was appropriately estimated from interference surface EMG when there was no MU synchronization. However, the estimated IZ was different from either of the two IZ locations used in the model for the other two MU synchronization conditions. For muscles with a single IZ, MU synchronization has little effect on IZ estimation from electrode array surface EMG. However, caution is required for multiple IZ muscles since MU synchronization might lead to false IZ estimation.


Asunto(s)
Músculo Esquelético/inervación , Simulación por Computador , Electrodos , Electromiografía , Humanos , Procesamiento de Señales Asistido por Computador
3.
Med Biol Eng Comput ; 57(9): 2045-2054, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31350669

RESUMEN

Interference surface electromyogram (EMG) reflects many bioelectric properties of active motor units (MU), which are however difficult to estimate due to the asynchronous summation of their discharges. This paper introduces a deconvolution technique to estimate the cumulative firings of MUs. Tests in simulations show that the power spectral density of the estimated MU firings has a low-frequency peak corresponding to the mean firing rate of MUs in the detection volume of the recording system, weighted by the amplitudes of MU action potentials. The peak increases in amplitude and its centroid shifts to a higher frequency when MU synchronization is simulated (mainly due to the shift of discharges of large MUs). The peak is found even at high force levels, when such a contribution does not emerge from the EMG. This result is also confirmed in preliminary applications to experimental data. Moreover, the simulated cumulative firings of MUs are estimated with a correlation above 90% (considering frequency contributions up to 150 Hz), for all force levels. The method requires a single EMG channel, thus being feasible even in applied studies using simple recording systems. It may open many potential applications, e.g., in the study of the modulation of MU firing rate induced by either fatigue or pathology and in coherency analysis. Graphical Abstract Examples of application of the deconvolution (Deconv) algorithm and comparison with the cumulative firings and the cumulated weighted firings (CWF, i.e., each firing pattern is weighted by the root mean squared amplitude of the corresponding MU action potential). Portions of data are shown on the left, the power spectral densities (PSD) on the right (Welch method applied to 3 s of data, sub-epochs of 0.5 s, mean value removed from each of them, 50% of overlap). A) Simulated signal (50% of maximal voluntary contraction, MVC) with random MU firings. B) Simulated signal (50% MVC) with a level of synchronization equal to 10%. C) Experimental data from vastus medialis at 40% MVC (data decomposed by the algorithm of Holobar and Zazula, IEEE Trans. Sig. Proc. 2007; PSD of the cumulated firings almost identical to that of CWF, as few MUs were identified).


Asunto(s)
Algoritmos , Electromiografía/métodos , Neuronas Motoras/fisiología , Fibras Musculares Esqueléticas/fisiología , Procesamiento de Señales Asistido por Computador , Potenciales de Acción/fisiología , Humanos , Contracción Muscular/fisiología
4.
J Appl Physiol (1985) ; 127(1): 205-214, 2019 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-31120812

RESUMEN

Correlation between motor unit discharge times, often referred to as motor unit synchronization, is determined by common synaptic input to motor neurons. Although it has been largely speculated that synchronization should influence the rate of force development, the association between the degree of motor unit synchronization and rapid force generation has not been determined. In this study, we examined this association with both simulations and experimental motor unit recordings. The analysis of experimental motor unit discharges from the tibialis anterior muscle of 20 healthy individuals during rapid isometric contractions revealed that the average motor unit discharge rate was associated with the rate of force development. Moreover, the extent of motor unit synchronization was entirely determined by the average motor unit discharge rate (R > 0.7, P < 0.0001). The simulation model demonstrated that the relative proportion of common synaptic input received by motor neurons, which determines motor unit synchronization, does not influence the rate of force development (R = 0.03, P > 0.05). Nonetheless, the estimates of correlation between motor unit spike trains were significantly correlated with the rate of force generation (R > 0.8, P < 0.0001). These results indicate that the average motor unit discharge rate, but not the degree of motor unit synchronization, contributes to most of the variance of human contractile speed among individuals. In addition, estimates of correlation between motor unit discharge times depend strongly on the number of identified motor units and therefore are not indicative of the strength of common input. NEW & NOTEWORTHY It is commonly assumed that motor unit synchronization has an impact on the rate of force development of a muscle. Here we present computer simulations and experimental data of human tibialis anterior motor units during rapid contractions that show that motor unit synchronization is not a determinant of the rate of force production. This conclusion clarifies the neural determinants of rapid force generation.


Asunto(s)
Neuronas Motoras/fisiología , Músculo Esquelético/fisiología , Sinapsis/fisiología , Potenciales de Acción/fisiología , Adulto , Simulación por Computador , Electromiografía/métodos , Humanos , Contracción Isométrica/fisiología , Masculino , Adulto Joven
5.
Hum Mov Sci ; 66: 273-284, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31078946

RESUMEN

The purpose of this study was to determine the degree of co-contraction as per electromyographic gamma-band intermuscular coherence of the quadricep (Q) and hamstring (H) muscles during single-leg squatting (SLS), and to assess the influence of sex and self-reported knee complaints on the association between knee injury history and medial and lateral Q-H intermuscular coherence. Participants included 34 individuals who suffered a youth sport-related intra-articular knee injury 3-12 years previously, and 37 individuals with no knee injury history. Surface electromyographic signals were recorded from medial and lateral thigh muscles bilaterally to determine the gamma-band (30-60 Hz) intermuscular coherence between medial and lateral Q-H muscle pairs during SLS. Multivariable linear regression (α = 0.05) was performed to investigate the relationship between knee injury history (main exposure) and medial and lateral Q-H coherence (outcome) while accounting for the influence of sex and self-reported knee pain and symptoms (covariates). The median age of participants was 25 (range 18-30) and 67% were female. Q-H gamma-band coherence was present for 60-90% of legs. Medial and lateral Q-H coherence was higher in females compared to males. There was no evidence for an association between medial Q-H coherence, knee injury history, knee pain, or symptoms. There was evidence for an association between knee injury history and lateral Q-H coherence, which was modified by sex such that previously injured males demonstrated reduced Q-H coherence compared to uninjured males. These finding suggest that females demonstrate a more pronounced Q-H co-contraction strategy during a SLS than males regardless of knee injury history. Further, that male who suffered a youth sport-related knee injury 3-12 years previously demonstrate less Q-H co-contraction during a SLS than uninjured males. The mechanisms behind differences in neuromuscular control between males and females as well as previously injured and uninjured males require further investigation.

6.
Front Physiol ; 9: 566, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29867587

RESUMEN

Introduction: The vasti muscles have to work in concert to control knee joint motion during movements like walking, running, or squatting. Coherence analysis between surface electromyography (EMG) signals is a common technique to study muscle synchronization during such movements and gain insight into strategies of the central nervous system to optimize neuromuscular performance. However, different assessment methods related to EMG data acquisition, e.g., different electrode configurations or amplifier technologies, have produced inconsistent observations. Therefore, the aim of this study was to elucidate the effect of different EMG acquisition techniques (monopolar vs. bipolar electrode configuration, potential vs. current amplifier) on the magnitude, reliability, and sensitivity of intermuscular coherence between two vasti muscles during stable and unstable squatting exercises. Methods: Surface EMG signals from vastus lateralis (VL) and medialis (VM) were obtained from eighteen adults while performing series of stable und unstable bipedal squats. The EMG signals were acquired using three different recording techniques: (1) Bipolar with a potential amplifier, (2) monopolar with a potential amplifier, and (3) monopolar electrodes with a current amplifier. VL-VM coherence between the respective raw EMG signals was determined during two trials of stable squatting and one trial of unstable squatting to compare the coherence magnitude, reliability, and sensitivity between EMG recording techniques. Results: VL-VM coherence was about twice as high for monopolar recordings compared to bipolar recordings for all squatting exercises while coherence was similar between monopolar potential and current recordings. Reliability measures were comparable between recording systems while the sensitivity to an increase in intermuscular coherence during unstable vs. stable squatting was lowest for the monopolar potential system. Discussion and Conclusion: The choice of electrode configuration can have a significant effect on the magnitude of EMG-EMG coherence, which may explain previous inconsistencies in the literature. A simple simulation of cross-talk could not explain the large differences in intermuscular coherence. It is speculated that inevitable errors in the alignment of the bipolar electrodes with the muscle fiber direction leads to a reduction of information content in the differential EMG signals and subsequently to a lower resolution for the detection of intermuscular coherence.

7.
J Electromyogr Kinesiol ; 24(6): 848-54, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25241214

RESUMEN

It was recently proposed that one could use signal current instead of voltage to collect surface electromyography (EMG). With EMG-current, the electrodes remain at the ground potential, thereby eliminating lateral currents. The purpose of this study was to determine whether EMG-currents can be recorded in Tap and Salt water, as well as in air, without electrically shielding the electrodes. It was hypothesized that signals would display consistent information between experimental conditions regarding muscle responses to changes in contraction effort. EMG-currents were recorded from the flexor digitorum muscles as participant's squeezed a pre-inflated blood pressure cuff bladder in each experimental condition at standardized efforts. EMG-current measurements performed underwater showed no loss of signal amplitude when compared to measurements made in air, although some differences in amplitude and spectral components were observed between conditions. However, signal amplitudes and frequencies displayed consistent behavior across contraction effort levels, irrespective of the experimental condition. This new method demonstrates that information regarding muscle activity is comparable between wet and dry conditions when using EMG-current. Considering the difficulties imposed by the need to waterproof traditional bipolar EMG electrodes when underwater, this new methodology is tremendously promising for assessments of muscular function in aquatic environments.


Asunto(s)
Aire , Amplificadores Electrónicos , Electromiografía/instrumentación , Inmersión , Músculo Esquelético/fisiología , Agua , Adulto , Amplificadores Electrónicos/normas , Electrodos/normas , Electromiografía/métodos , Electromiografía/normas , Femenino , Humanos , Contracción Isométrica/fisiología , Masculino , Adulto Joven
8.
Comput Methods Programs Biomed ; 113(1): 314-22, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24183387

RESUMEN

This study aims to reproduce the effect of motor-unit synchronization on surface EMG recordings during vibratory stimulation to highlight vibration evoked muscle activity. The authors intended to evaluate, through numerical simulations, the changes in surface EMG spectrum in muscles undergoing whole body vibration stimulation. In some specific bands, in fact, vibration induced motion artifacts are also typically present. In addition, authors meant to compare the simulated EMGs with respect to real recordings in order to discriminate the effect of synchronization of motor units discharges with vibration frequencies from motion artifacts. Computations were performed using a model derived from previous studies and modified to consider the effect of vibratory stimulus, the motor unit synchronization and the endplates-electrodes relative position on the EMG signal. Results revealed that, in particular conditions, synchronization of MUs' discharge generates visible peaks at stimulation frequency and its harmonics. However, only a part of the total power of surface EMGs might be enclosed within artifacts related bands (± 1 Hz centered at the stimulation frequency and its superior harmonics) even in case of strong synchronization of motor units discharges with the vibratory stimulus.


Asunto(s)
Electromiografía , Músculos/fisiología , Potenciales de Acción , Electrodos , Humanos , Músculos/inervación , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA