RESUMEN
ABSTRACT Introduction Differential counting of erythroblasts in blood samples by hematology analyzers still has limitations. Technological advances in blood count equipment have proposed the fully automated counting of these cells, however, not without its validation. Objective Validate the automated count of erythroblasts in peripheral blood in the Mindray BC6000 hematology analyzer and verify the existence of correlation of the maturation stages of erythroblasts with the equipment's graphics. Material and Methods Prospective study with peripheral blood samples from the Clinical Pathology Laboratory Dr Paulo C. Azevedo, regardless of age and gender, to validate the erythroblast count in the Mindray BC6000 hematology analyzer compared to the manual method (gold standard), in the period of June 2019 to December 2020. Results Seventeen peripheral blood samples were analyzed from newborns (09/17 - 52.3%) and from patients older than 2 years (08/17 - 47.7%) who had more than 18% of erythroblasts after morphological analysis of the sample. Statistical analysis of erythroblast counts by the two methodologies showed that the Mindray BC6000 hematological counter has good reproducibility, precision and linearity. There was no correlation between the maturation stages of erythroblasts and the equipment graphics. Conclusion The proposed validation showed that the Mindray BC6000 hematological counter has good analytical performance for counting erythroblasts in peripheral blood. However, there is no correlation between the maturation stages of erythroblasts with the graphics generated by the equipment.
RESUMO Introdução A contagem diferencial de eritroblastos em amostras de sangue por analisadores de hematologia ainda apresenta limitações. Os avanços tecnológicos nos equipamentos de hemograma têm proposto a contagem totalmente automatizada dessas células, porém, não sem sua validação. Objetivo Validar a contagem automatizada de eritroblastos no sangue periférico no analisador hematológico Mindray BC6000 e verificar a existência de correlação dos estágios de maturação dos eritroblastos com os gráficos do equipamento. Material e Métodos Estudo prospectivo com amostras de sangue periférico do Laboratório de Patologia Clínica Dr. Paulo C. Azevedo, independente de idade e sexo, para validação da contagem de eritroblastos no analisador hematológico Mindray BC6000 em comparação ao método manual (padrão ouro), no período de junho de 2019 a dezembro de 2020. Resultados Foram analisadas 17 amostras de sangue periférico de recém-nascidos (17/09 - 52,3%) e de pacientes maiores de 2 anos (17/08 - 47,7%) que apresentavam mais de 18% de eritroblastos após análise morfológica da amostra. A análise estatística das contagens de eritroblastos pelas duas metodologias mostrou que o contador hematológico Mindray BC6000 tem boa reprodutibilidade, precisão e linearidade. Não houve correlação entre os estágios de maturação dos eritroblastos e os gráficos do equipamento. Conclusão A validação proposta mostrou que o contador hematológico Mindray BC6000 apresenta bom desempenho analítico para contagem de eritroblastos em sangue periférico. Porém, não há correlação entre os estágios de maturação dos eritroblastos com os gráficos gerados pelo equipamento.
Asunto(s)
Candida parapsilosis/aislamiento & purificación , Candidiasis/sangre , Fungemia/sangre , Candidiasis/diagnóstico , Candidiasis/microbiología , Preescolar , Diagnóstico Precoz , Fungemia/diagnóstico , Fungemia/microbiología , Pruebas Hematológicas/instrumentación , Humanos , Recuento de Leucocitos , Masculino , Reproducibilidad de los ResultadosRESUMEN
ABSTRACT Introduction: Pseudothrombocytopenia is an important source of pre-analytical problems in clinical laboratory; therefore it must be correctly evaluated. Low spurious platelet counts can lead to misdiagnosis. Objective: This study aims to study the resolution of pseudothrombocytopenia in the laboratory routine of clinical laboratory by standardizing the use of vortexer. Methods: This is a cross-sectional, analytical, quantitative study based on experimental approach, involving 45 pseudothrombocytopenia samples divided into three groups and submitted to vortexing for 1, 2 and 3 minutes. Results: During the study, 28,435 blood counts were performed, and 56 (0.196%) of these samples confirmed platelet aggregates. The 2 and 3 minute times normalized the platelet count (greater than 150,000/µl) in two thirds of the samples tested. Platelets, hemolysis index, platelet distribution width (PDW) and mean platelet volume (MPV) presented statistically significant mean difference (MD) (p < 0.05) after vortexing at all times. Conclusion: The 2 and 3-minute times were the most effective in the resolution of pseudothrombocytopenia, however, the 2 minutes time should be preferred because it produced fewer effects on the erythrocyte membrane.
RESUMO Introdução: A pseudotrombocitopenia constitui importante fonte de problemas pré-analíticos no laboratório clínico, por isso deve ser corretamente avaliada. Baixas contagens de plaquetas espúrias podem levar a suspeitas diagnósticas equivocadas. Objetivo: Este estudo se propôs a estudar a resolução da pseudotrombocitopenia na rotina de laboratório de análises clínicas pela padronização do uso de vortex. Métodos: Trata-se de um estudo transversal analítico e quantitativo, apresentando-se dentro de uma abordagem de cunho experimental, o qual envolveu 45 amostras pseudotrombocitopênicas divididas em três grupos e submetidas a agitação com vortex nos tempos de 1, 2 e 3 minutos. Resultados: Durante a realização do estudo, foram realizados 28.435 hemogramas, sendo 56 (0,196%) amostras confirmadas com a presença de agregados plaquetários. Os tempos de 2 e 3 minutos normalizaram a contagem de plaquetas (maior que 150.000/µl), em dois terços das amostras testadas. Plaquetas, índice de hemólise, amplitude de distribuição das plaquetas (PDW) e volume plaquetário médio (VPM) apresentaram diferença de média estatisticamente significativa (p < 0,05) após o tratamento com vortex em todos os tempos testados. Conclusão: Os tempos de 2 e 3 minutos foram os mais eficazes na resolução da pseudotrombociopenia, contudo, o tempo de 2 minutos deve ser utilizado por ter produzido menores efeitos sobre a membrana eritrocitária.
RESUMEN
ABSTRACT Introduction: Body fluid (BF) analysis is critical to the diagnosis and monitoring of several pathological conditions. The limitations of manual cell counts have led to greater interest in the development of automated BF analysis. Objective: To evaluate the analytical performance of the Sysmex XE-5000 hematology analyzer in the analysis of pleural and ascitic fluids in the laboratory routine of a large university hospital. Methods: A total of 56 samples (35 ascitic and 21 pleural fluids) were analyzed by manual optical microscopy (OM) and XE-5000. Analytical performance includes linearity, carryover, functional sensitivity and comparison of patient samples. Results: Performance studies showed linearity up to 25,825 WBC-BF/µl (r2 = 0.999), WBC-BF showed carryover of 0.18%, and the lower limit of quantitation was set at 22 WBC-BF/µl. Good correlations between the methods were observed just for total cell (TC-BF) and white blood cell (WBC-BF) counts in pleural and ascitic fluids. The high-fluorescence cell count (HF-BF) showed poor correlation but high positive predictive value (PPV) for both fluids (94.74% for pleural and 96.97% for ascitic fluid). Conclusion: XE-5000 provides accurate and precise count for TC-BF, WBC-BF and polymorphonuclear cells (PMN-BF) in pleural and ascitic fluids in medical decision levels, but the morphological differentiation should continue to be held by OM. Histogram and scattergram displayed on XE-5000 must always be analyzed to assess if there is any interference or flag. The HF-BF parameter is a potential tool for screening.
RESUMO Introdução: A análise de líquidos corporais é fundamental para o diagnóstico e o acompanhamento de várias condições patológicas. Devido às limitações da contagem manual de células, tem ocorrido maior interesse no desenvolvimento da análise automatizada de líquidos corporais. Objetivo: Verificar o desempenho analítico do analisador hematológico Sysmex XE-5000 na análise de fluidos pleurais e ascíticos na rotina laboratorial de um hospital universitário de grande porte. Métodos: Um total de 56 amostras (35 de líquidos ascíticos e 21 de líquidos pleurais) foi analisado por microscopia ótica manual (MOM) e pelo XE-5000. O estudo de verificação incluiu linearidade, carryover, limite de quantificação e comparação de amostras de pacientes. Resultados: O estudo de verificação mostrou linearidade de até 25.825 WBC-BF/ml (r2 = 0,999); WBC-BF, carryover de 0,18%; e o menor limite de quantificação foi fixado em 22 WBC-BF/ml. Boas correlações entre o método manual e o automatizado foram observadas apenas para as contagens de total de células nucleadas (TC-BF) e glóbulos brancos (WBC-BF) em líquidos pleurais e ascíticos. A contagem de células de alta fluorescência (HF-BF) mostrou correlação fraca, porém valor preditivo positivo (VPP) elevado para ambos os líquidos corporais (94,74% pleural; 96,97% ascítico). Conclusão: O XE-5000 fornece contagem confiável para TC-BF, WBC-BF e células polimorfonucleares (PMN-BF) em fluidos pleurais e ascíticos em níveis de decisão médica, contudo a diferenciação morfológica deve continuar a ser realizada por MOM. O histograma e o diagrama de dispersão exibidos no XE-5000 devem ser sempre avaliados quanto à existência de qualquer interferência ou alerta suspeito. A contagem de HF-BF constitui uma potencial ferramenta para triagem.
RESUMEN
OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.
OBJETIVO: o objetivo deste estudo foi avaliar se a abertura e o fechamento repetitivo do clipe de braquetes autoligáveis podem causar deformação plástica do clipe.MÉTODOS: três tipos de braquetes autoligáveis ativos/interativos estéticos (n = 20) foram testados: In-Ovation C, Quicklear e WOW. Um dispositivo realizou, de forma controlada e padronizada, 500 ciclos de abertura e de fechamento do clipe, com instrumentos e técnicas adequadas, tal como recomendado pelo fabricante de cada tipo de braquete. Dois ensaios de tração, um antes e um depois dos ciclos repetitivos, foram realizados para se avaliar a rigidez dos clipes. Para o ensaio de tração, um fio de 0,40 x 0,40mm de aço inoxidável foi inserido no slot do braquete e adaptado em uma máquina universal de ensaios (EMIC DL2000), sendo as medições registradas. Na porção retilínea da curva de carregamento dos clipes, a inclinação é definida por uma equação de primeiro grau, determinando o coeficiente de elasticidade (rigidez) do clipe.RESULTADOS: os resultados quanto à deformação plástica não mostraram nenhuma diferença significativa entre os tipos de braquetes, antes e depois dos 500 ciclos de abertura e de fechamento (p = 0,811). Foram encontradas diferenças significativas na rigidez entre os três tipos de braquetes (p = 0,005): o braquete WOW demonstrou valores médios mais elevados, e o braquete Quicklear demonstrou valores mais baixos, independentemente do ciclo de abertura e fechamento.CONCLUSÃO: movimentos repetitivos controlados de abertura e de fechamento do clipe não alteraram a rigidez ou causaram deformação plástica.
Asunto(s)
Cerámica/química , Soportes Ortodóncicos , Diseño de Aparato Ortodóncico , Aleaciones Dentales/química , Materiales Dentales/química , Alambres para Ortodoncia , Acero Inoxidable/química , Estrés Mecánico , Resistencia a la Tracción , Ensayo de Materiales , Docilidad , Análisis del Estrés Dental/instrumentación , Fenómenos Mecánicos , Módulo de ElasticidadRESUMEN
En este artículo se presenta un informe rápido de evaluación de tecnología sanitaria sobre la incorporación de un sistema de cultivo microbiano automatizado para la realización de pruebas de identificación y sensibilidad antibiótica de gérmenes en el laboratorio de microbiología de un hospital público de alta complejidad de la provincia del Neuquén.(AU)
Asunto(s)
Humanos , Enfermedades Transmisibles/microbiología , Automatización de Laboratorios/métodos , Hospitales Públicos , Evaluación en Salud/economía , Farmacorresistencia Microbiana , Análisis Costo-Beneficio/economíaRESUMEN
INTRODUCTION AND OBJECTIVE: To evaluate the performance of red cell distribution width reported statistically as coefficient of variation (RDW-CV), standard deviation (RDW-SD), and mathematical deduction of 1 standard deviation (SD) around mean corpuscular volume (MATH-1SD) in identifying anisocytosis in automated blood counts when compared with the manual quantification of erythrocyte anisocytosis in peripheral blood smears. MATERIAL AND METHODS: 806 routine samples obtained from the hematology laboratory of Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR) were analyzed. Performance evaluations were carried out by dividing samples into microcytic, normocytic and macrocytic mean corpuscular volume (MCV). For each MCV range, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and efficiency were calculated. In addition, the Youden index (Y) was obtained and a comparative analysis with receiver operating characteristic (ROC) curves was done to evaluate the performance of RDW-SD, RDW-CV, and MATH-1SD on different MCV ranges. RESULTS AND DISCUSSION: RDW-CV had the best sensitivity (86.8%) and efficiency (86.8%) in detecting anisocytosis in microcytic MCV ranges. RDW-SD and MATH-1SD were more sensitive and efficient in normocytic (82.9% and 83.3%; 92.1% and 92.3%, respectively) and macrocytic (90.2% and 90.2%; 95.1% and 95.1%, respectively) MCV ranges. A ROC curve analysis indicated that RDW-CV was more efficient in detecting anisocytosis in microcytic MCV ranges (p < 0.05 vs. RDW-SD and MATH-1SD). In normocytic and macrocytic MCV ranges, RDW-SD and MATH-1SD showed similar efficiency in detecting anisocytosis (p < 0.05 vs. RDW-CV). CONCLUSION: RDW-SD, RDW-CV, and MATH-1SD deliver different performances in detecting blood smear anisocytosis according to MCV values. They are parameters that complement each other and should be used together to identify erythrocyte size heterogeneity.
INTRODUÇÃO E OBJETIVO: Avaliar o desempenho do red cell distribution width expresso em coeficiente de variação (RDW-CV) e desvio padrão (RDW-SD) e da dedução matemática de 1 desvio padrão (DP) ao redor do volume corpuscular médio (MATH-1SD) ao identificar anisocitose nos hemogramas automatizados, quando comparados com o método manual de quantificação da anisocitose eritrocitária em lâmina. MATERIAL E MÉTODOS: Foram analisadas 806 amostras obtidas da rotina laboratorial da Seção de Hematologia do Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR). As avaliações de desempenho foram realizadas dividindo-se as amostras em volume corpuscular médio (VCM) microcítico, VCM normocítico e VCM macrocítico. Para cada faixa de VCM, sensibilidade, especificidade, valor preditivo positivo (VPP), valor preditivo negativo (VPN) e eficiência foram determinados. Além disso, o índice de Youden foi calculado e uma análise comparativa de curvas de características de operação do receptor (curvas ROC [receiver operating characteristic]) foi realizada para verificar o desempenho de RDW-CV, RDW-SD e MATH-1SD em diferentes faixas de VCM. RESULTADOS E DISCUSSÃO: O RDW-CV obteve a melhor sensibilidade (86,8%) e eficiência (86,8%) ao detectar anisocitose em faixas de VCM microcítico. O RDW-SD e o MATH 1SD foram mais sensíveis e eficientes em VCM normocítico (82,9% e 83,3%; 92,1% e 92,3%, respectivamente) e macrocítico (90,2% e 90,2%; 95,1% e 95,1%, respectivamente). A comparação de curvas ROC demonstrou que o RDW-CV foi mais eficiente ao detectar anisocitose em VCM microcítico (p < 0,05 vs. RDW-SD e MATH-1SD). Em VCM normocítico e macrocítico, o RDW-SD e o MATH-1SD mostraram eficiência semelhante ao detectar anisocitose (p < 0,05 vs. RDW-CV). CONCLUSÃO: RDW-CV, RDW-SD e MATH-1SD possuem desempenhos diferentes ao detectar anisocitose em lâmina conforme a faixa de VCM. São parâmetros que se complementam e que devem ser utilizados em conjunto na identificação de heterogeneidade dos tamanhos eritrocitários.