Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38854708

RESUMEN

Endoscopic ultrasound (EUS)-guided pancreatic duct drainage includes two procedures: EUS-guided drainage/anastomosis (EUS-D/A) and trans-papillary drainage with EUS-assisted pancreatic rendezvous. EUS-guided pancreatogastrostomy is the most common EUS-D/A procedure and is recommended as a salvage procedure in cases in which endoscopic retrograde cholangiopancreatography fails or is difficult. However, initial EUS-D/A is performed in patients with surgically altered anatomy at our institution. It is one of the most difficult interventional EUS procedures and has a high incidence of adverse events. The technical difficulties differ according to etiology, and the incidence of adverse events varies between initial EUS-D/A and subsequent trans-endosonographically/EUS-guided created route procedures. Hence, it is important to meticulously prepare a procedure based on the patient's condition and the available devices. The technical difficulties in EUS-D/A include: (1) determination of the puncture point, (2) selection of a puncture needle and guidewire, (3) guidewire manipulation, and (4) dilation of the puncture route and stenting. Proper technical procedures are important to increase the success rate and reduce the incidence and severity of adverse events. The complexity of EUS-D/A is also contingent on the severity of pancreatic fibrosis and stricture. In post-pancreatectomy cases, determination of the puncture site is important for success because of the remnant pancreas. Trans-endosonographically/EUS-guided created route procedures following initial EUS-D/A are also important for achieving the treatment goal. This article focuses on effective strategies for initial EUS-D/A, based on the etiology and condition of the pancreas. We mainly discuss EUS-D/A, including its indications, techniques, and success-enhancing strategies.

2.
Gastrointest Endosc ; 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39278283

RESUMEN

BACKGROUND AND AIMS: Endoscopic ultrasound-guided biliary drainage (EUS-BD) has shown promising procedural outcomes in high-volume centers. While inferior procedural outcomes were reported in inexperienced centers during the early days of EUS-BD, the current outcomes are unknown. This study aimed to clarify the feasibility and safety of EUS-BD in centers that recently introduced EUS-BD. METHODS: This multicenter retrospective study was conducted at 22 centers that introduced EUS-BD between 2017 and 2022. A maximum of 20 initial EUS-BD cases at each center were evaluated. The clinical outcomes and experience of 84 endoscopists who performed these procedures were examined. The primary outcomes were the rate of technical success and adverse events (AEs). The secondary outcomes were risk factors associated with technical failure and procedure-related AEs. RESULTS: A total of 255 patients were enrolled. The technical success rate was 91.4% (233/255). Among technical failure cases (n=22), guidewire manipulation failure was the most common cause (n=12), followed by tract dilation failure (n=5). The AE rate was 10.2% (26/255). Multivariate analysis identified a puncture target diameter of <5 mm (odds ratio, 3.719; 95% confidence interval, 1.415-9.776; p=0.008) and moderate ascites extending to the liver surface (odds ratio, 3.25; 95% confidence interval, 1.195-8.653; p=0.021) as independent risk factors for technical failure and procedure-related AEs, respectively. Endoscopists' procedural experience was not a risk factor for technical failure or procedure-related AEs. CONCLUSIONS: The feasibility and safety of EUS-BD were maintained during the induction phase at inexperienced centers. These will be helpful in better understanding the current status of EUS-BD.

3.
Dig Endosc ; 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39162053

RESUMEN

In recent years, the usefulness of endoscopic ultrasound (EUS) has been recognized in children. A dedicated pediatric EUS scope has not been developed; in our experience, however, an adult EUS scope can be used. The American Society for Gastrointestinal Endoscopy Technical Committee status assessment report on pediatric endoscopy equipment provides some guidance on the feasibility of EUS according to body size. Careful monitoring is required, keeping in mind potential adverse events such as cervical esophageal perforation and unstable breathing due to tracheal compression. Most devices designed for interventional pancreatobiliary endoscopy are also available for children. Sedation or intubated general anesthesia (GA) is mandatory when performing interventional EUS (I-EUS). I-EUS for children is generally performed using GA in the operating room, but sedation in the endoscopy room is also possible under appropriate monitoring by pediatricians. I-EUS in the operating room is sometimes difficult for endoscopists to perform because of the unsuitable fluoroscopic imaging and the lack of familiar equipment and staff. Compared to GA, sedation in the endoscopy room facilitates easier and quicker repetition of procedures when necessary. Adult pancreatobiliary endoscopists perform most I-EUS procedures in the pediatric population because most pediatric endoscopists have few opportunities to perform EUS-related procedures and thus have difficulty maintaining their skills. To popularize I-EUS techniques for children, it will be necessary to establish a training program for developing pediatric endoscopists.

4.
Endosc Int Open ; 12(7): E861-E867, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38989255

RESUMEN

Background and study aims The proximity of a pancreas head tumor to the duodenum often limits delivery of an ablative dose of radiation therapy. This study evaluated the feasibility and safety of using an injectable polyethylene glycol (PEG) hydrogel between the head of the pancreas and duodenum. Patients and methods In a multi-site feasibility cohort study of patients with localized pancreatic cancer, PEG hydrogel was injected under endoscopic ultrasound guidance to temporarily position the duodenum away from the pancreas. Procedure characteristics were recorded, including hydrogel volume and space created. Patients were monitored for adverse events (AEs) and radiotherapy toxicity. Results In all six intent-to-treat patients (four with borderline resectable, two with locally advanced disease), the ability to place and visualize PEG hydrogel and create space between the duodenum and the head of the pancreas was successful. There were no procedure-related AEs resulting in radiotherapy delay. There were no device-related AEs and no reports of pancreatitis. Conclusions PEG hydrogel was successfully placed, created space between the duodenum and the head of the pancreas, and was not associated with major toxicity. Enhancing radiotherapy for pancreatic cancer by using PEG hydrogel to create peri-duodenal space could have beneficial implications for treatment and warrants more exploration.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39075945

RESUMEN

BACKGROUND: Self-expandable metal stent (SEMS) migration after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is a severe complication. The migration risk could be related to the surface friction of SEMS, assumed to be affected by the wire structure and mechanical properties, including radial force (RF); however, their relevance remains unclear. This experimental study aimed to assess the mechanical properties of SEMS involved in the onset of stent migration by measuring the sliding-resistance force (SF) as the SEMS moves through the stomach wall. METHODS: The SF of seven types of 8-mm diameter SEMS (four braided and three laser-cut types) and porcine stomach wall was measured with a universal testing machine. The SF of each SEMS was measured three times, and the average maximum SF (SFmax) was used for analysis. The correlation between SFmax and RF of each SEMS was evaluated. RESULTS: SFmax and RF showed a very strong positive correlation (r = 0.92). Compared to the regression line predictions in the scatter plots of SFmax and RF, the SFmax of laser-cut and braided type SEMSs had positive and negative residuals, respectively. CONCLUSIONS: Selecting a laser-cut type SEMS with a higher RF may more effectively prevent the onset of stent migration against the stomach wall in EUS-HGS.

6.
Best Pract Res Clin Gastroenterol ; 69: 101888, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38749575

RESUMEN

In the last decades, Endoscopic ultrasound (EUS) has rapidly grown and evolved from being mainly a diagnostic procedure, to being an interventional and therapeutic tool in several pathological clinical scenarios. With the progressive growth in technical expertise and dedicated devices, interventional endoscopic ultrasound procedures (IEUSP) have shown high rates of technical and clinical success, together with a relatively safe profile. However, the description and the standardization of different and specific types of adverse events (AEs) are still scarce in literature, and, consequently, even less the management of AEs. The aim of this study is to critical review and to describe AEs related to each of the main IEUSP, and to provide an overview on the possible management strategies of endoscopic complications. Future studies and guidelines are surely required to reach a better standardization of different AEs and their best management.


Asunto(s)
Endosonografía , Ultrasonografía Intervencional , Humanos , Endosonografía/efectos adversos , Endosonografía/instrumentación , Endosonografía/normas , Endosonografía/métodos , Ultrasonografía Intervencional/efectos adversos
7.
J Clin Med ; 13(10)2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38792381

RESUMEN

Background/Objective: Interventional endoscopic ultrasound (I-EUS) is technically difficult and has risks of severe adverse events due to the scarcity of dedicated endoscopes and tools. A new EUS scope was developed for I-EUS and was modified to increase the puncture range, reduce the blind area, and overcome guidewire difficulties. We evaluated the usefulness and safety of a new EUS scope compared to a conventional EUS scope. Methods: All I-EUS procedures were performed at Juntendo University Hospital from April 2020 to April 2022. The primary outcomes included the procedure time and fluoroscopy time. The secondary outcomes included the technical success rate and the rates of procedure-related adverse events. Clinical data were retrospectively reviewed and statistically analyzed between the new and conventional EUS scopes. Results: In total, 143 procedures in 120 patients were analyzed. The procedure time was significantly shorter with the new EUS scope, but the fluoroscopy time was not different. Among the patients only undergoing EUS-guided biliary drainage (EUS-BD), 79 procedures in 74 patients were analyzed. Both the procedure time and fluoroscopy time were significantly shorter with the new EUS scope. Multivariate analysis revealed that a new EUS scope and use of covered metal stents could reduce the fluoroscopy time. The technical success rate and the adverse event rate were not significantly different between the total I-EUS and the EUS-BD only groups. However, the conventional scope showed stent deviation during stent placement, which did not happen with the new scope. Conclusions: The new EUS scope reduced procedure time for total I-EUS and fluoroscopy time for EUS-BD compared to a conventional EUS scope because of the improvement suitable for I-EUS.

8.
Gastrointest Endosc Clin N Am ; 34(3): 553-575, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38796299

RESUMEN

Pancreatic fluid collections (PFCs) are commonly encountered complications of acute and chronic pancreatitis. With the advancement of endoscopic ultrasound (EUS) techniques and devices, EUS-directed transmural drainage of symptomatic or infected PFCs has become the standard of care. Traditionally, plastic stents have been used for drainage, although lumen-apposing metal stents (LAMSs) are now favored by most endoscopists due to ease of use and reduced procedure time. While safety has been repeatedly demonstrated, follow-up care for these patients is critical as delayed adverse events of indwelling drains are known to occur.


Asunto(s)
Drenaje , Endosonografía , Pancreatitis , Stents , Humanos , Drenaje/métodos , Drenaje/instrumentación , Endosonografía/métodos , Stents/efectos adversos , Pancreatitis/etiología , Seudoquiste Pancreático/cirugía , Seudoquiste Pancreático/diagnóstico por imagen
10.
Endosc Int Open ; 12(5): E666-E675, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38707594

RESUMEN

Background and study aims To develop a pancreatobiliary endoscopic guidewire with good clinical performance, an understanding of its structure is necessary. This study aimed to investigate the structural factors influencing the clinical performance of pancreatobiliary endoscopic guidewires. Methods Eight types of 0.025-inch guidewires were evaluated. The following structural properties were measured: tip length, tip deflection height, tip weight (TW), ratio of tip core weight to TW, shaft coating type (flat or uneven), outer diameter, and core wire diameter (CWD). Four performance tests were conducted to evaluate shaft stiffness as bending force (BF), shaft lubricity as friction force (FF), torque response as torque response rate (TRR), and seeking ability as total insertion success (TIS) in a technical test using a 3D bile duct model. The correlation coefficients of each variable were analyzed. Results The BF and CWDs were strongly correlated, as well as the FF and CWDs and BF. Among the guidewires with similar CWDs, the guidewires with uneven coating had significantly lower FF than those with flat coating. The TRR was strongly correlated with the CWDs; furthermore, guidewires with lower FF had better TRR. TIS was strongly correlated with the TRR, TWs, and ratio of the tip core weight to TW. Conclusions CWD affects shaft stiffness; CWD and coating type affect shaft lubricity and torque response. Because TRR and TW are correlated with seeking ability, an appropriate combination of core wire thickness, TW, and coating design is required to develop a guidewire with good seeking ability.

11.
Medicina (Kaunas) ; 60(4)2024 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-38674279

RESUMEN

In recent years, therapeutic endoscopy has become a fundamental tool in the management of gallbladder diseases in light of its minimal invasiveness, high clinical efficacy, and good safety profile. Both endoscopic transpapillary gallbladder drainage (TGBD) and endoscopic ultrasound (EUS)-guided gallbladder drainage (EUS-GBD) provide effective internal drainage in patients with acute cholecystitis unfit for cholecystectomy, avoiding the drawbacks of external percutaneous gallbladder drainage (PGBD). The availability of dedicated lumen-apposing metal stents (LAMS) for EUS-guided transluminal interventions contributed to the expansion of endoscopic therapies for acute cholecystitis, making endoscopic gallbladder drainage easier, faster, and hence more widely available. Moreover, EUS-GBD with LAMS opened the possibility of several cholecystoscopy-guided interventions, such as gallstone lithotripsy and clearance. Finally, EUS-GBD has also been proposed as a rescue drainage modality in malignant biliary obstruction after failure of standard techniques, with encouraging results. In this review, we will describe the TBGD and EUS-GBD techniques, and we will discuss the available data on clinical efficacy in different settings in comparison with PGBD. Finally, we will comment on the future perspectives of EUS-GBD, discussing the areas of uncertainty in which new data are more strongly awaited.


Asunto(s)
Drenaje , Endosonografía , Humanos , Drenaje/métodos , Endosonografía/métodos , Colecistitis Aguda/cirugía , Vesícula Biliar/cirugía , Vesícula Biliar/diagnóstico por imagen , Stents , Endoscopía/métodos , Enfermedades de la Vesícula Biliar/cirugía
12.
Surg Endosc ; 38(4): 2288-2296, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38488871

RESUMEN

BACKGROUND: Thin delivery system stents can be inserted directly without the need for a tract dilation step and are expected to reduce bile leakage during endoscopic ultrasound-guided biliary drainage (EUS-BD). The present study retrospectively compared the safety and efficacy of EUS-BD using a thin metal stent (< 7.5 Fr) with those of EUS-BD using a conventional stent (≥ 7.5 Fr). METHODS: The present study enrolled 112 patients who underwent EUS-BD using metal stents for unresectable malignant biliary obstruction between April 2016 and July 2022. The primary endpoint was the rate of adverse events (AEs). The secondary endpoints were clinical success rate, procedure time, procedure success rate in the absence of the tract dilation step, recurrent biliary obstruction rate, time to biliary obstruction, and overall survival. Risk factors associated with early AEs were also evaluated. RESULTS: The rate of early AEs was significantly lower (12% vs. 35%, P = 0.013) and the procedure success without the tract dilation step was significantly higher (82% vs. 33%, P < 0.001) in the thin than in the conventional delivery system stent group. None of the other secondary endpoints differed significantly between the two groups. Multivariate analysis showed that employing the tract dilation step during EUS-BD was a significant independent risk factor for early AEs (skipping vs. employing; HR, 9.66; 95% CI, 1.13-83.0, P = 0.028). CONCLUSION: Employing the tract dilation step during EUS-BD was a significant risk factor for early AEs. Metal stents with a delivery diameter < 7.5 Fr can be inserted directly without the tract dilation step, resulting in lower early AE rates.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Colestasis , Humanos , Estudios Retrospectivos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Dilatación/efectos adversos , Colestasis/etiología , Colestasis/cirugía , Endosonografía/métodos , Stents/efectos adversos , Drenaje/efectos adversos , Drenaje/métodos , Ultrasonografía Intervencional/efectos adversos
13.
Intern Med ; 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38403760

RESUMEN

Objective Adverse events such as bile leakage and bleeding are among the issues that need to be resolved in EUS-guided choledochoduodenostomy (EUS-CDS). To overcome this problem, we developed a new EUS-CDS technique using a 19-G Franseen needle without tract dilation. This study aimed to evaluate the safety and efficacy of the new EUS-CDS technique. Methods This single-center retrospective study included 20 consecutive patients who underwent EUS-CDS for primary drainage using a 19-G Franseen needle between March 2020 and May 2023. The primary endpoint was the technical success rate of EUS-CDS without tract dilation. Results The technical success rate of EUS-CDS was 20/20 (100%). None of the patients required any additional tract dilation, such as by using a balloon or electric cautery. The median procedure time was 7.8 (range, 3.2-19.4) min. No early adverse events were observed. Conclusion The 19-G Franseen needle appeared to have a sufficient dilatory effect during puncturing. This EUS-CDS technique appears to be safe and effective and has the advantages of no adverse events and it is also a simplified procedure, which suggests its potential for widespread use in primary drainage.

14.
Intern Med ; 63(18): 2525-2531, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38346739

RESUMEN

Abscesses associated with gallbladder perforation are often confined to the peri-gallbladder region. We herein report a rare case of gallbladder perforation in which the abscess cavity extended into the left upper quadrant. A 79-year-old woman developed gallbladder perforation secondary to acalculous cholecystitis. Computed tomography revealed fluid collection extending from the peri-gallbladder to the dorsal left hepatic lobe in contact with the stomach. We successfully treated percutaneous transhepatic gallbladder drainage and simultaneous endoscopic ultrasound-guided transgastric internal and external abscess drainage. This minimally invasive approach is considered safe and feasible for managing such a rare case.


Asunto(s)
Absceso , Drenaje , Endosonografía , Enfermedades de la Vesícula Biliar , Humanos , Femenino , Anciano , Drenaje/métodos , Absceso/diagnóstico por imagen , Absceso/cirugía , Absceso/etiología , Endosonografía/métodos , Enfermedades de la Vesícula Biliar/diagnóstico por imagen , Enfermedades de la Vesícula Biliar/cirugía , Enfermedades de la Vesícula Biliar/complicaciones , Vesícula Biliar/diagnóstico por imagen , Vesícula Biliar/cirugía
15.
Dig Endosc ; 36(3): 351-358, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37253185

RESUMEN

OBJECTIVES: Endoscopic retrograde cholangiopancreatography (ERCP) represents the gold standard for jaundice palliation in patients with distal malignant biliary obstruction (DMBO). Biliary drainage using electrocautery lumen apposing metal stent (EC-LAMS) is currently a well-established procedure when ERCP fails. In a palliative setting the endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) could represent an easy and valid option. We performed a prospective study with a new EC-LAMS with the primary aim to assess the clinical success rate of EUS-GBD as a first-line approach to the palliation of DMBO. METHODS: In all, 37 consecutive patients undergoing EUS-GBD with a new EC-LAMS were prospectively enrolled. Clinical success was defined as bilirubin level decrease >15% within 24 h and >50% within 14 days after EC-LAMS placement. RESULTS: The mean age was 73.5 ± 10.8 years; there were 17 male patients (45.9%). EC-LAMS placement was technically feasible in all patients (100%) and the clinical success rate was 100%. Four patients (10.8%) experienced adverse events, one bleeding, one food impaction, and two cystic duct obstructions because of disease progression. No stent-related deaths were observed. The mean hospitalization was 7.7 ± 3.4 days. Median overall survival was 4 months (95% confidence interval 1-8). CONCLUSION: Endoscopic ultrasound-guided gallbladder drainage with the new EC-LAMS is a valid option in palliative endoscopic biliary drainage as a first-step approach in low survival patients with malignant jaundice unfit for surgery. A smaller diameter EC-LAMS should be preferred, particularly if the drainage is performed through the stomach, to avoid potential food impaction, which could result in stent dysfunction.


Asunto(s)
Colestasis , Ictericia , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Vesícula Biliar , Estudios Prospectivos , Colestasis/diagnóstico por imagen , Colestasis/etiología , Colestasis/cirugía , Endosonografía/métodos , Ictericia/complicaciones , Drenaje/métodos , Stents/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Ultrasonografía Intervencional/métodos
16.
J Hepatobiliary Pancreat Sci ; 31(2): e5-e7, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37814402

RESUMEN

Endoscopic ultrasound-guided rendezvous with a 22-gauge needle and a 0.018-inch guidewire, assisted by a 3-Fr microcatheter, effectively addresses challenges in biliary cannulation, improving guidewire manipulation and reducing risks of injury and leakage. Natsume and colleagues describe the successful extraction of common bile duct stones to demonstrate the efficacy of this technique.


Asunto(s)
Cateterismo , Colangiopancreatografia Retrógrada Endoscópica , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Cateterismo/métodos , Endosonografía/métodos , Agujas , Drenaje/métodos , Ultrasonografía Intervencional
17.
JGH Open ; 7(5): 358-364, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37265928

RESUMEN

Background and Aim: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is widely used in the management of biliary obstructions; however, literature on guidewire manipulation is lacking. This study aimed to assess the utility and optimal conditions of the loop technique for guidewire manipulation during EUS-HGS. Methods: Consecutive patients who underwent EUS-HGS between April 2015 and January 2022 were included in this study. Patient characteristics and procedural details were retrospectively analyzed. Guidewire manipulations were classified as conventional technique or loop technique, based on the shape of the guidewire tip. Results: A total of 52 patients (Median age: 73 years, 38 male and 14 female) underwent EUS-HGS. The median guidewire insertion time was 49 s and the median overall procedure time was 20.5 min. The initial guidewire direction was toward the peripheral side in 23 patients (44%). Technical success rate of the EUS-HGS was 100%. Twenty patients (38%) underwent the procedure using the loop technique and 32 (62%) with the conventional technique. In the logistic regression analysis, an angle between the bile duct and needle of >70° was independently associated with use of the loop technique (OR 9.84; 95% CI: 2.24-43.13; P <0.01). Conclusion: This study revealed the utility of the loop technique in EUS-HGS. This technique is recommended if the bile duct is punctured at an angle >70°.

18.
J Clin Med ; 12(9)2023 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-37176764

RESUMEN

Since its emergence as a diagnostic modality in the 1980s, endoscopic ultrasound (EUS) has provided the clinician profound access to gastrointestinal organs to aid in the direct visualization, sampling, and subsequent identification of pancreatic pathology. In recent years, advancements in EUS as an interventional technique have promoted the use of local ablative therapies as a minimally invasive alternative to the surgical management of pancreatic neuroendocrine tumors (pNETs) and pancreatic cystic neoplasms (PCNs), especially for those deemed to be poor operative candidates. EUS-guided local therapies have demonstrated promising efficacy in addressing a spectrum of pancreatic neoplasms, while also balancing local adverse effects on healthy parenchyma. This article serves as a review of the current literature detailing the mechanisms, outcomes, complications, and limitations of EUS-guided local ablative therapies such as chemical ablation and radiofrequency ablation (RFA) for the treatment of pNETs and PCNs, as well as a discussion of future applications of EUS-guided techniques to address a broader scope of pancreatic pathology.

19.
Endosc Ultrasound ; 12(2): 266-272, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37148139

RESUMEN

Background and Objectives: EUS-guided hepaticogastrostomy (EUS-HGS) is an effective salvage procedure when conventional endoscopic transpapillary biliary drainage is difficult or fails. However, the risk of stent migration into the abdominal cavity has not been resolved completely. In this study, we evaluated a newly developed partially covered self-expandable metallic stent (PC-SEMS) that has a spring-like anchoring function on the gastric side. Methods: This retrospective pilot study took place at four referral centers in Japan between October 2019 and November 2020. We enrolled 37 cases consecutively who underwent EUS-HGS for unresectable malignant biliary obstruction. Results: The rates of technical and clinical success were 97.3% and 89.2%, respectively. Technical failures included one case in which the stent was dislocated during the removal of the delivery system, requiring additional EUS-HGS on another branch. Early adverse events (AEs) were observed in four patients (10.8%): two with mild peritonitis (5.4%) and one each (2.7%) with fever and bleeding. No late AEs were observed during the mean follow-up period of 5.1 months. All recurrent biliary obstructions (RBOs) were stent occlusions (29.7%). The median cumulative time to RBO was 7.1 months (95% confidence interval, 4.3 to not available). Although stent migration in which the stopper was in contact with the gastric wall on follow-up computed tomography was observed in six patients (16.2%), no migration was observed. Conclusions: The newly developed PC-SEMS is feasible and safe for the EUS-HGS procedure. The spring-like anchoring function on the gastric side is an effective anchor preventing migration.

20.
Dig Liver Dis ; 55(5): 644-648, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36890050

RESUMEN

BACKGROUND AND AIM: Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for the treatment of gastric outlet obstruction (GOO) has been actually performed only with one type of electrocautery lumen-apposing metal stents (EC-LAMS). We aimed to evaluate the safety, technical and clinical effectiveness of EUS-GE using a newly available EC-LAMS in patients with malignant and benign GOO. MATERIALS AND METHODS: Consecutive patients who underwent EUS-GE for GOO using the new EC-LAMS at five endoscopic referral centers were retrospectively evaluated. Clinical efficacy was determined utilizing the Gastric Outlet Obstruction Scoring System (GOOSS). RESULTS: Twenty-five patients (64% male, mean age 68.7 ± 9.3 years) met the inclusion criteria; 21 (84%) had malignant etiology. Technically, EUS-GE was successful in all patients, with a mean procedural time of 35 ± 5 min. Clinical success was 68% at 7 days and 100% at 30 days. The mean time to resume oral diet was 11.4 ± 5.8 h, with an improvement of at least one point of GOOSS score observed in all patients. The median hospital stay was 4 days. No procedure-related adverse events occurred. After a mean follow-up of 7.6 months (95% CI 4.6-9.2), no stent dysfunctions were observed. CONCLUSION: This study suggests EUS-GE can be performed safely and successfully using the new EC-LAMS. Future large multicenter prospective studies are needed to confirm our preliminary data.


Asunto(s)
Obstrucción de la Salida Gástrica , Ultrasonografía Intervencional , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Electrocoagulación/efectos adversos , Endosonografía , Obstrucción de la Salida Gástrica/etiología , Obstrucción de la Salida Gástrica/cirugía , Gastroenterostomía/efectos adversos , Estudios Retrospectivos , Stents/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA