Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Womens Health (Lond) ; 19: 17455057231218195, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38126304

RESUMEN

BACKGROUND: Maternal health service utilization decreases maternal morbidity and mortality. However, the existing evidence is inadequate to design effective intervention strategies in Ethiopia. OBJECTIVES: This study aimed to examine the utilization of maternal health service and identify its determinants among women of reproductive age in southern Ethiopia. DESIGN: A community-based cross-sectional study was conducted from October 21 to November 11, 2022 on a sample of 1140 women selected randomly from the Northern Zone of the Sidama region. METHODS: Data were collected using the Open Data Kit mobile application and exported to Stata version 15 for analysis. We used a multilevel mixed-effects modified Poisson regression with robust standard error to identify determinants of maternal health service utilization. RESULTS: Utilization of antenatal care, health facility delivery, and postnatal care was 52.0% (95% confidence interval: 49.0%, 55.0%), 48.5% (95% confidence interval: 45.6%, 51.4%), and 26.0% (95% confidence interval: 23.0%, 29.0%), respectively. Antenatal care use was associated with receiving model family training (adjusted prevalence ratio: 1.19; 95% confidence interval: 1.06, 1.35), knowledge of antenatal care (adjusted prevalence ratio: 1.54; 95% confidence interval: 1.31, 1.81), perceived quality of antenatal care (adjusted prevalence ratio: 1.02; 95% confidence interval: 1.01, 1.03), and having birth preparedness plan (adjusted prevalence ratio: 1.13; 95% confidence interval: 1.02, 1.25). The identified determinants of health facility delivery use were middle wealth rank (adjusted prevalence ratio: 1.35; 95% confidence interval: 1.03, 1.77), perceived quality of health facility delivery (adjusted prevalence ratio: 1.02; 95% confidence interval: 1.01, 1.03), antenatal care (adjusted prevalence ratio: 1.76; 95% confidence interval: 1.36, 2.26), and high community-level women literacy (adjusted prevalence ratio: 1.55; 95% confidence interval: 1.10, 2.19). Postnatal care use was associated with facing health problems during postpartum period (adjusted prevalence ratio: 1.79; 95% confidence interval: 1.18, 2.72), urban residence (adjusted prevalence ratio: 3.52; 95% confidence interval: 2.15, 5.78), knowledge of postnatal care (adjusted prevalence ratio: 1.11; 95% confidence interval: 1.04, 1.19), and low community-level poverty (adjusted prevalence ratio: 0.43; 95% confidence interval: 0.25, 0.73). CONCLUSION: Maternal health service use was low in the study area and was influenced by individual- and community-level determinants. Any intervention strategies must consider multi-sectorial collaboration to address determinants at different levels. The programs should focus on the provision of model family training, the needs of women who have a poor perception, and knowledge of maternal health service at the individual level.


Asunto(s)
Servicios de Salud Materna , Femenino , Embarazo , Humanos , Análisis Multinivel , Etiopía/epidemiología , Estudios Transversales , Parto Obstétrico , Atención Prenatal , Aceptación de la Atención de Salud
2.
Sci Total Environ ; 850: 157873, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-35940260

RESUMEN

Parabens, triclosan (TCS), bisphenols, benzophenones, and phthalates are typical endocrine disruptors (EDs) with short half-lives in the human body. The concentration levels of those EDs in a spot urine sample are frequently used in exposure assessment studies, and the reproducibility of urinary levels of these nonpersistent EDs should be considered. In the present study, we consecutively collected 45-day first morning void (FMV) urine samples, as well as daily questionnaires, in six recruited participants and measured the urinary concentrations of six parabens, TCS, nine bisphenols, five benzophenones, and ten phthalate metabolites by using high-performance liquid chromatography-tandem mass spectrometry. MeP, EtP, PrP, TCS, BPA, BPS, BPF, and most phthalate metabolites were frequently detected (over 62 % of samples). The intraclass correlation coefficients (ICCs) for ED concentrations in FMV urine samples ranged from fair to excellent for MeP (0.683), EtP (0.702), BPA (0.505), BPS (0.908), BPF (0.887), BP-3 (0.712), mMP (0.661), mEP (0.523), mBP (0.500), miBP (0.724), mBzP (0.961) and all metabolites of DEHP (0.867-0.957), whereas they were low for PrP (0.321) and TCS (0.306). After creatinine adjustment, the values of ICCs for most target EDs were increased with mild to significant improvement. The stability of ED concentrations was affected by daily diet (MeP, TCS, BPA, mMP, miBP, mBP and mBzP), food containers (PrP and mECPP), use of personal care products (HMWP metabolites), pharmaceuticals (EtP) and recorded activities (BPS, mEHP, mBzP, mEHHP and mEOHP), as confirmed by a general linear mixed model. Furthermore, extending the FMV sampling period improved the probability of acceptable reproducibility (ICCs > 0.40) of MeP, EtP, BP-3 and mEP concentrations. For BPS, BPF and HMWP metabolite concentrations showed high probabilities (>80 %) of acceptable reproducibility in the last three days, and the increasing sample size slowly improved the ability to discriminate the subjects. The results were exactly the opposite for BPA concentrations.


Asunto(s)
Cosméticos , Dietilhexil Ftalato , Disruptores Endocrinos , Contaminantes Ambientales , Ácidos Ftálicos , Triclosán , Compuestos de Bencidrilo , Benzofenonas/análisis , Cosméticos/análisis , Creatinina , Exposición a Riesgos Ambientales , Contaminantes Ambientales/análisis , Humanos , Estilo de Vida , Parabenos/análisis , Preparaciones Farmacéuticas , Fenoles , Ácidos Ftálicos/orina , Reproducibilidad de los Resultados , Triclosán/análisis
3.
Arch Rehabil Res Clin Transl ; 4(2): 100186, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35756979

RESUMEN

Objective: To examine the effect of digital physical therapy (PT) delivered by mobile application (app) on reducing pain and improving function for people with a variety of musculoskeletal conditions. Design: An observational, longitudinal, retrospective study using survey data collected pre- and postdigital PT to estimate multilevel models with random intercepts for patient episodes. Setting: Privately insured employees participating in app-based PT as an employer health care benefit. Participants: The study sample included 814 participants (N=814) 18 years or older who completed their digital PT program with reported final clinical outcomes between February 2019 (program launch) through December 2020. Mean age of the sample at baseline was 40.9±11.89 years, 47.5% were female, 21% sought care for lower back pain, 16% for shoulders, 15% for knees, and 13% for neck. Interventions: Digital PT consisted of a synchronous video evaluation with a physical therapist followed by a course of PT delivered through a mobile app. Main Outcome Measures: Pain was measured by the visual analog scale from 0 "no pain" to 10 "worst pain imaginable" and physical function by the Patient-Specific Functional Scale on a scale from 0 "completely unable to perform" to 10 "able to perform normally." Results: After controlling for significant demographics, comorbid conditions, adverse symptoms, chronicity, and severity, the results from multilevel random intercept models showed decreased pain (-2.69 points; 95% CI, -2.86 to -2.53; P<.001) and increased physical function (+2.67 points; 95% CI, 2.45-2.89; P<.001) after treatment. Conclusions: Digital PT was associated with clinically meaningful improvements in pain and function among a diverse set of participants. These early data are an encouraging indicator of the clinical benefit of digital PT.

4.
Womens Health (Lond) ; 18: 17455057221099505, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35603662

RESUMEN

BACKGROUND: The maternal mortality rate in poor nations remains unacceptably high. The purpose of this study was to identify factors associated with institutional delivery usage. METHODS: The data came from the Ethiopian mini demographic and health survey, which was conducted in 2019. This study comprised 3978 women of reproductive age who had given birth within the previous 5 years. To uncover significantly linked parameters associated with institutional delivery, we used a multilevel logistic regression model. Statistical significance was declared at p < 0.05, and we assessed the strength of association using adjusted odds ratios with 95% confidence intervals. RESULTS: More than half of the women (53.67%) among 3978 women with last birth had their babies delivered in a health facility. In the multilevel logistic regression analysis, women in age group 45-49 (AOR = 2.43, 95% CI: 1.280, 4.591), primary educational level (AOR = 2.21, 95% CI: 1.864, 2.625, secondary and above education level (AOR = 6.37, 95% CI: 4.600, 8.837), being Muslim (AOR = 2.57, 95% CI: 1.245, 2.166), women who visited ANC service four up to seven times (AOR = 2.75, 95% CI: 2.175, 3.473), women visited ANC service eight times and above (AOR = 3.295% CI: 1.685, 6.050), women who reside in middle wealth index (AOR = 1.57, 95% CI: 1.273, 1.950), and rich wealth index (AOR = 3.43, 95% CI: 2.782, 4.225) were more likely to give birth at health institution compared to their counterparts. Furthermore, women being in rural area (AOR = 0.34, 95% CI:- 0.283, 0.474) and protestant women (AOR = 0.1.57, 95% CI: 0.479, 0.852) were less likely to deliver at health institution. CONCLUSIONS: Ethiopia still has a low level of institutionalized delivery. Institutional delivery in Ethiopia should be improved through context-specific and personalized programs, such as educating women and enhancing access to ANC services.


Asunto(s)
Parto Obstétrico , Instituciones de Salud , Preescolar , Escolaridad , Etiopía/epidemiología , Femenino , Humanos , Análisis Multinivel , Oportunidad Relativa , Embarazo , Atención Prenatal
5.
EClinicalMedicine ; 46: 101348, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35340629

RESUMEN

Background: Accurate prediction of treatment response to neoadjuvant chemotherapy (NACT) in individual patients with locally advanced gastric cancer (LAGC) is essential for personalized medicine. We aimed to develop and validate a deep learning radiomics nomogram (DLRN) based on pretreatment contrast-enhanced computed tomography (CT) images and clinical features to predict the response to NACT in patients with LAGC. Methods: 719 patients with LAGC were retrospectively recruited from four Chinese hospitals between Dec 1st, 2014 and Nov 30th, 2020. The training cohort and internal validation cohort (IVC), comprising 243 and 103 patients, respectively, were randomly selected from center I; the external validation cohort1 (EVC1) comprised 207 patients from center II; and EVC2 comprised 166 patients from another two hospitals. Two imaging signatures, reflecting the phenotypes of the deep learning and handcrafted radiomics features, were constructed from the pretreatment portal venous-phase CT images. A four-step procedure, including reproducibility evaluation, the univariable analysis, the LASSO method, and the multivariable logistic regression analysis, was applied for feature selection and signature building. The integrated DLRN was then developed for the added value of the imaging signatures to independent clinicopathological factors for predicting the response to NACT. The prediction performance was assessed with respect to discrimination, calibration, and clinical usefulness. Kaplan-Meier survival curves based on the DLRN were used to estimate the disease-free survival (DFS) in the follow-up cohort (n = 300). Findings: The DLRN showed satisfactory discrimination of good response to NACT and yielded the areas under the receiver operating curve (AUCs) of 0.829 (95% CI, 0.739-0.920), 0.804 (95% CI, 0.732-0.877), and 0.827 (95% CI, 0.755-0.900) in the internal and two external validation cohorts, respectively, with good calibration in all cohorts (p > 0.05). Furthermore, the DLRN performed significantly better than the clinical model (p < 0.001). Decision curve analysis confirmed that the DLRN was clinically useful. Besides, DLRN was significantly associated with the DFS of patients with LAGC (p < 0.05). Interpretation: A deep learning-based radiomics nomogram exhibited a promising performance for predicting therapeutic response and clinical outcomes in patients with LAGC, which could provide valuable information for individualized treatment.

6.
BMC Musculoskelet Disord ; 22(1): 899, 2021 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-34696744

RESUMEN

BACKGROUND: Standing whole spinal radiographs are used to evaluate spinal alignment in adult spinal deformity (ASD), yet some studies have reported that pelvic incidence, pelvic tilt, and thoracic kyphosis (TK) intra- and inter-observer reliability is low. This study aimed to evaluate the accuracy of spinopelvic parameters through comparing standing whole spinal radiographs and upright CT images. METHODS: We enrolled 26 patients with ASD. All standing whole spinal posterior/anterior and lateral radiographs and upright whole spinal CT had been obtained in a natural standing position. Two examiners independently measured 13 radiographic parameters. Interclass correlation coefficients (ICCs) were used to analyze measurement intra- and inter-observer reliability. Paired t- and Pearson's correlation tests were used to analyze validity of the standing whole spinal radiographs. RESULTS: ICCs of upright CT were excellent in both intra- and inter-observer reliability. However, intra-observer ICCs for TK2-12, TK1-5, TK2-5, and TK5-12 on standing lateral radiographs were relatively low, as were inter-observer ICCs for TK2-12, TK1-5, TK2-5, and TK5-12. Concerning TK values, the difference between the radiographs and CT in TK1-12 and TK2-12 were 4.4 ± 3.1 and 6.6 ± 4.6, respectively, and TK values from T2 showed greater measurement error (p < 0.05). CONCLUSIONS: Upright CT showed excellent intra- and inter-observer reliability in the measurement of spinopelvic parameters. Measurement of TK with T2 on standing whole spinal radiographs resulted in a greater measurement error of up to 6.6°. Surgeons need to consider this when planning surgery and measuring postoperative TK changes in patients with ASD.


Asunto(s)
Columna Vertebral , Posición de Pie , Adulto , Humanos , Radiografía , Reproducibilidad de los Resultados , Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X
7.
J Clin Lab Anal ; 35(10): e23976, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34427961

RESUMEN

BACKGROUND: A comparison study is crucial before launching a new medical device; therefore, we compared the Mission Ultra Hb Testing System with the Sysmex XN-3000 automated hematology analyzer in Thai adult males and non-pregnant adult females. METHODS: Parallel studies were conducted using discarded venous K2-ethylenediaminetetraacetic acid samples from participants requiring hematological investigations. According to the World Health Organization criteria, the participants were categorized as overall, anemia, and non-anemia for analysis. RESULTS: Three hundred participants were included in this study. In all participants, near-perfect correlation and agreement were observed between the two methods for Hb measurement (r = 0.963, p < 0.001) with an interclass correlation coefficient (ICC) of 0.981 (95% confidence interval [CI]: 0.976-0.985) and Hct measurement (r = 0.941, p < 0.001) with an ICC of 0.965 (95% CI: 0.956-0.972). The sensitivity and specificity of the device in detecting anemia were 86.2% (95% CI: 79.7-91.2) and 98.6% (95% CI: 95.2-99.8), respectively. The area under the curve was 0.976 (95% CI: 0.963-0.989). The device showed average biases of 0.76 g/dl (95% limits of agreement [LOA]: -1.03 to 2.54) for Hb measurement and -2.73% (95% LOA: -9.28 to 3.82) for Hct measurement in all participants. CONCLUSION: Agreement between the Mission Ultra Hb Testing System and Sysmex XN-3000 was observed. The device was excellent for detecting anemia. However, the essential evidence showing biases of the Hb and Hct measurements obtained from the device was revealed. Laboratory interpretation should be carefully performed, particularly at the near cut-off values.


Asunto(s)
Anemia/diagnóstico , Pruebas Hematológicas/métodos , Hemoglobinas/análisis , Pruebas en el Punto de Atención , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tailandia , Adulto Joven
8.
Sensors (Basel) ; 21(9)2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34062943

RESUMEN

This study aimed to investigate the accuracy and reliability of hip and ankle worn Actigraph GT3X+ (AG) accelerometers to measure steps as a function of gait speed. Additionally, the effect of the low frequency extension filter (LFEF) on the step accuracy was determined. Thirty healthy individuals walked straight and walked with continuous turns in different gait speeds. Number of steps were recorded with a hip and ankle worn AG, and with a Stepwatch (SW) activity monitor positioned around the right ankle, which was used as a reference for step count. The percentage agreement, interclass correlation coefficients and Bland-Altmann plots were determined between the AG and the reference SW across gait speeds for the two walking conditions. The ankle worn AG with the default filter was the most sensitive for step detection at >0.6 m/s, whilst accurate step detection for gait speeds < 0.6 m/s were only observed when applying the LFEF. The hip worn AG with the default filter showed poor accuracy (12-78%) at gait speeds < 1.0 m/s whereas the accuracy increased to >87% for gait speeds < 1.0 m/s when applying the LFEF. Ankle worn AG was the most sensitive to measure steps at a vast range of gait speeds. Our results suggest that sensor placement and filter settings need to be taken into account to provide accurate estimates of step counts.


Asunto(s)
Velocidad al Caminar , Caminata , Acelerometría , Tobillo , Marcha , Humanos , Reproducibilidad de los Resultados
9.
Sports Med Health Sci ; 3(3): 157-164, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35784521

RESUMEN

We recently observed a high prevalence of low pelvic bone mineral density (BMD) in female professional ballet performers. Because this population is susceptible to musculoskeletal overuse injuries, we aimed to determine which regions of the pelvis may be at greatest risk compared to general population females (GENPOP) as well as professional female soccer players (SOCCER, a comparison to other elite athletes regularly subjected to high degrees of loading). Three groups of age-matched females [(GENPOP; n = 38, 27±1yrs), (BALLET; single company, n = 36, 26±3yrs), (SOCCER; single NWSL® club, n = 34, 25±1yrs)] consented to have their BMD and body composition assessed (DEXA, GE®). In addition to soft tissue and total and regional BMD analyses, a segmental analysis of the pelvis was performed to determine site-specific BMD for the iliac fossa, iliac fossa/iliac crest/ilium combined, pubic bone, ischium, and sacrum. A mixed-model ANOVA followed by a Tukey's post-hoc test was used to compare the groups (Type-I error; α = 0.05). The BALLET group had lower pelvic BMD for all measures (Avg.%Diff. = 15%-27%, p<0.001) compared to the SOCCER group and for the ischium (Avg.%Diff.= 8%; p=0.007) and sacrum (Avg.%Diff. â€‹= â€‹7%; p = 0.028) compared to the GENPOP group. The BALLET group had lower lean mass for all measures compared to the other groups (Avg.%Diff. = 12%-18%; p < 0.01). Professional ballet performers exhibit reduced pelvic region soft tissue and site-specific BMD not previously detected using standard DEXA analyses. These findings highlight which pelvic regions may benefit from preventative strength training and/or nutritional interventions.

10.
Artículo en Inglés | MEDLINE | ID: mdl-32913656

RESUMEN

BACKGROUND: Developmental disorders (DDs) in children are a priority condition and guidelines have been developed for their management within low-resource community settings. However, a key obstacle is lack of open access, reliable and valid tools that lay health workers can use to evaluate the impact of such programmes on child outcomes. We adapted and validated the World Health Organization's Disability Assessment Schedule for children (WHODAS-Child), a lay health worker-administered functioning-related tool, for children with DDs in Pakistan. METHODS: Lay health workers administered a version of the WHODAS-Child to parents of children with DDs (N = 400) and without DDs (N = 400), aged 2-12 years, after it was adapted using qualitative study. Factor analysis, validity, reliability and sensitivity to change analyses were conducted to evaluate the psychometric properties of the adapted outcome measure. RESULTS: Among 800 children, 58% of children were male [mean (s.d.) age 6.68 (s.d. = 2.89)]. Confirmatory Factor Analysis showed a robust factor structure [χ2/df 2.86, RMSEA 0.068 (90% CI 0.064-0.073); Tucker-Lewis Index (TLI) 0.92; Comparative Fit Index (CFI) 0.93; Incremental Fit Index (IFI) 0.93]. The tool demonstrated high internal consistency (α 0.82-0.94), test-retest [Intra-class Correlation Coefficient (ICC) 0.71-0.98] and inter-data collector (ICC 0.97-0.99) reliabilities; good criterion (r -0.71), convergent (r -0.35 to 0.71) and discriminative [M (s.d.) 52.00 (s.d. = 21.97) v. 2.14 (s.d. = 4.00); 95% CI -52.05 to -47.67] validities; and adequate sensitivity to change over time (ES 0.19-0.23). CONCLUSIONS: The lay health worker administrated version of adapted WHODAS-Child is a reliable, valid and sensitive-to-change measure of functional disability in children aged 2-12 years with DDs in rural community settings of Pakistan.

11.
Neurosurg Focus ; 49(2): E8, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32738801

RESUMEN

OBJECTIVE: One vexing problem after lateral lumbar interbody fusion (LLIF) surgery is cage subsidence. Low bone mineral density (BMD) may contribute to subsidence, and BMD is correlated with Hounsfield units (HUs) on CT. The authors investigated if lower HU values correlated with subsidence after LLIF. METHODS: A retrospective study of patients undergoing single-level LLIF with pedicle screw fixation for degenerative conditions at the University of California, San Francisco, by 6 spine surgeons was performed. Data on demographics, cage parameters, preoperative HUs on CT, and postoperative subsidence were collected. Thirty-six-inch standing radiographs were used to measure segmental lordosis, disc space height, and subsidence; data were collected immediately postoperatively and at 1 year. Subsidence was graded using a published grade of disc height loss: grade 0, 0%-24%; grade I, 25%-49%; grade II, 50%-74%; and grade III, 75%-100%. HU values were measured on preoperative CT from L1 to L5, and each lumbar vertebral body HU was measured 4 separate times. RESULTS: After identifying 138 patients who underwent LLIF, 68 met the study inclusion criteria. All patients had single-level LLIF with pedicle screw fixation. The mean follow-up duration was 25.3 ± 10.4 months. There were 40 patients who had grade 0 subsidence, 15 grade I, 9 grade II, and 4 grade III. There were no significant differences in age, sex, BMI, or smoking. There were no significant differences in cage sizes, cage lordosis, and preoperative disc height. The mean segmental HU (the average HU value of the two vertebrae above and below the LLIF) was 169.5 ± 45 for grade 0, 130.3 ± 56.2 for grade I, 100.7 ± 30.2 for grade II, and 119.9 ± 52.9 for grade III (p < 0.001). After using a receiver operating characteristic curve to establish separation criteria between mild and severe subsidence, the most appropriate threshold of HU value was 135.02 between mild and severe subsidence (sensitivity 60%, specificity 92.3%). After univariate and multivariate analysis, preoperative segmental HU value was an independent risk factor for severe cage subsidence (p = 0.017, OR 15.694, 95% CI 1.621-151.961). CONCLUSIONS: Lower HU values on preoperative CT are associated with cage subsidence after LLIF. Measurement of preoperative HU values on CT may be useful when planning LLIF surgery.


Asunto(s)
Tornillos Pediculares , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Enfermedades de la Columna Vertebral/cirugía , Fusión Vertebral/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Densidad Ósea/fisiología , Femenino , Humanos , Vértebras Lumbares , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
Rev. cuba. oftalmol ; 32(4): e767, oct.-dic. 2019. tab
Artículo en Español | LILACS, CUMED | ID: biblio-1099095

RESUMEN

RESUMEN Objetivo: Estimar los valores morfológicos y morfométricos del endotelio corneal según la cantidad de células y evaluar la concordancia interobservadores para los diferentes parámetros, considerados según los diferentes conteos celulares en adultos sin alteraciones corneales. Métodos: Se realizó una investigación observacional, descriptiva y transversal de serie de casos en el Servicio de Cirugía Refractiva del Instituto Cubano de Oftalmología "Ramón Pando Ferrer" en dos años de estudio. Después de aplicar los criterios de exclusión, la muestra quedó conformada por 200 ojos de 100 pacientes adultos sin alteraciones corneales. Se realizó microscopia endotelial de no contacto SP-3000P, para identificar los valores morfológicos (hexagonalidad y coeficiente de variabilidad) y morfométricos (densidad celular), así como el promedio del tamaño celular corneal según cantidad de células evaluadas. Resultados: Según la cantidad de células endoteliales evaluadas, no existieron diferencias significativas de las variables morfológicas y morfométricas (p> 0,05) en ambos ojos. La concordancia entre los diferentes conteos celulares según los valores de los coeficientes de correlación intraclase fueron todos altos. La concordancia interobservadores (excepto para la hexagonalidad) y los coeficientes de correlación intraclase fueron altos. Conclusiones: Los valores morfológicos y morfométricos del endotelio corneal según cantidad de células evaluadas, son similares en todos los conteos celulares. Se demuestra una buena concordancia entre los diferentes conteos celulares estudiados para los diferentes parámetros estimados(AU)


ABSTRACT Objective: To estimate the morphological and morphometric values of the corneal endothelium according to the number of cells and evaluate the interobserver concordance for the different parameters, estimated according to the different cell counts in adults without corneal alterations. Methods: An observational, descriptive and cross-sectional case series research was carried out in the Refractive Surgery Service of Ramón Pando Ferrer Cuban Institute of Ophthalmology during two years of study. After applying the exclusion criteria, the sample was made up of 200 eyes of 100 adult patients without corneal alterations. Non-contact endothelial microscopy SP-3000P was performed to identify morphological values (hexagonality and coefficient of variability) and morphometric values (cell density), as well as the average corneal cell size according to the number of cells evaluated. Results: According to the amount of endothelial cells evaluated, there were no significant differences between morphological and morphometric variables (p>0.05) in both eyes. The agreement between the different cell counts according to the values of the interclass correlation coefficients (ICC) were all high. The interobserver concordance and ICCs were also high, except for hexagonality. Conclusions: The morphological and morphometric values of the corneal endothelium, according to the number of cells evaluated, are similar in all cell counts. Good concordance between the different cell counts studied for the different estimated parameters is demonstrated(AU)


Asunto(s)
Humanos , Endotelio Corneal/fisiología , Epidemiología Descriptiva , Estudios Transversales , Microscopía Confocal/métodos , Estudios Observacionales como Asunto
13.
Int J Ophthalmol ; 12(8): 1311-1316, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31456922

RESUMEN

AIM: To explore whether the same corneal curvature parameters and anterior chamber depth measured by Pentacam and VX120 have a good consistency and can replace each other. METHODS: This study enrolled 140 eyes of 70 patients ranging in age from 19 to 53y. All eyes underwent a comprehensive ophthalmologic examination including an anterior segment analysis with the VX120 system (Visionix-Luneau Technologies, Chartres, France) and Pentacam (Oculus Optikgerate GmbH) respectively. The comparison on corneal curvature parameters was done between Pentacam and VX120 using clustered signed rank test; the interclass correlation coefficients (ICC) with 95% confidence intervals (CI) was calculated for each parameter between Pentacam and VX120; the Bland-Altman plot of each parameter was supplemented. RESULTS: The anterior corneal curvature measured by VX120 was Ks: 44.00±1.78 D, KsAt: 89.45±22.18, Kf: 42.84±1.58 D, KfAt: 93.91±79.34; which measured by Pentacam was Ks: 43.80±1.82 D, KsAt: 91.17±21.40, Kf: 42.61±1.64 D, KfAt: 91.16±78.69. There was statistical difference between Pentacam and VX120 for anterior corneal curvature parameter (P<0.001). The posterior corneal curvature measured by VX120 was Ks: -6.42±1.23 D, KsAt: 91.00±23.45, Kf: -5.85±1.24 D, KfAt: 95.93±79.11; which measured by Pentacam was Ks: -6.44±0.32 D, KsAt: 92.24±11.75, Kf: -6.01±1.05 D, KfAt: 74.43±80.64. There was statistical difference between Pentacam and VX120 for posterior corneal curvature parameters (P<0.001). Anterior chamber depth (ACD) measured by Pentacam and VX120 was statistically different. Pentacam and VX120 achieved high consistency only on corneal anterior surface, including Ks and Kf. The ICCs were 0.96 (95%CI: 0.95, 0.97) and 0.95 (95%CI: 0.94, 0.97) respectively. For other corneal surface curvature parameters, all ICCs of between Pentacam and VX120 were below 0.87. Bland-Altman plots indicated of low consistency of corneal surface curvature parameters measured by Pentacam and VX120. CONCLUSION: The corneal curvature parameters and anterior chamber depth measured by Pentacam and VX120 were statistically different. Data measured by Pentacam and VX120 is not suggested to replace each other, mixing data measured by Pentacam and VX120 together is not suggested either.

14.
J Neurosurg Spine ; : 1-6, 2019 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-31174186

RESUMEN

OBJECTIVE: Local bone dust has been used previously as a substitute cage filling material for iliac bone grafts during anterior cervical discectomy and fusion (ACDF). However, the impacts of local bone dust on fusion rate and clinical results remain unclear. Extragraft bone bridging (ExGBB) is a reliable CT finding indicating segmental fusion. This study was conducted to compare fusion rates for the use of local bone dust or an iliac auto bone graft during ACDF surgery and to evaluate the effect of implanting bone graft outside the cage. METHODS: Ninety-three patients who underwent ACDF at a single institution were included. An iliac bone graft was used as the polyetheretherketone (PEEK) cage filling graft material in 43 patients (iliac crest [IC] group). In the IC group, bone graft material was inserted only inside the cage. Local bone dust was used in 50 patients (local bone [LB] group). Bone graft material was inserted both inside and outside the cage in the LB group. Segmental fusion was assessed by 1) interspinous motion (ISM), 2) intragraft bone bridging (InGBB), and 3) ExGBB. Fusion rates, visual analog scale (VAS) scores for neck and arm pain, and Neck Disability Index (NDI) scores were compared between the 2 groups. RESULTS: The neck and arm pain VAS scores and NDI score improved significantly in both groups. Fusion rates assessed by ISM and InGBB did not differ significantly between the groups. However, the fusion rate in the LB group was significantly higher than that in the IC group when assessed by ExGBB (p = 0.02). CONCLUSIONS: Using local bone dust as cage filling material resulted in fusion rates similar to those for an iliac bone graft, while avoiding potential complications and pain caused by iliac bone harvesting. A higher rate of extragraft bone bridge formation was achieved by implanting local bone dust outside the cage.

15.
Parasitology ; 146(5): 563-568, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30419971

RESUMEN

Little is known about the genetic and morphological characters of Taenia ovis. The purpose of the present study was to characterize sheep isolates of T. ovis using rostellar hook morphometry as well as mitochondrial genes sequence analysis. Ninety sheep specimens of Cysticercus ovis were collected from 18 slaughterhouses in Iran. The mean ± s.d. for total length of large and small hooks were 174.1 ± 6.4 and 116.7 ± 5.4 µm, respectively. CO1 and 12S rRNA sequence analysis showed 11 and nine haplotypes, respectively. The level of pairwise nucleotide variations between individual haplotypes of CO1 and 12S rRNA genes were 0.3-1.1 and 0.2-1.0%, respectively. Level of nucleotide variation in CO1 and 12S rRNA between T. ovis haplotypes from present study and eight other Taenia species was found to be 11.3-17.8 and 5.3-16.3%, respectively. Phylogenetic analysis clustered all T. ovis isolates into a single clade comprised of the all CO1 and 12S rRNA haplotypes. CO1 nucleotide difference between T. ovis ovis and T. asiatica was 13.6% that is lesser than the corresponding difference between T. ovis ovis and T. ovis krabbei, warranting the designation of two separate species as T. ovis and T. krabbei. Interclass correlation coefficients showed that there was no significant association between rostellar hook length variation and the variability of the mitochondrial genes.


Asunto(s)
Variación Genética , Enfermedades de las Ovejas/parasitología , Taenia/anatomía & histología , Taenia/genética , Teniasis/veterinaria , Animales , Complejo IV de Transporte de Electrones/análisis , Proteínas del Helminto/análisis , Irán , Larva/anatomía & histología , Proteínas Mitocondriales/análisis , ARN de Helminto/análisis , ARN Ribosómico/análisis , Ovinos , Taenia/crecimiento & desarrollo , Teniasis/parasitología
16.
Acad Radiol ; 26(8): e216-e223, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30201435

RESUMEN

RATIONALE AND OBJECTIVES: To explore the imaging features of whole uterus volume CT perfusion (vCTP) and the influence factors of blood supply in cervical squamous carcinoma (CSC). MATERIALS AND METHODS: vCTP was performed on a 640-slice computed tomography system in 43 patients with CSC diagnosed by biopsy, and 24 cases of them underwent magnetic resonance imaging. The size of the tumor was measured on vCTP and magnetic resonance (MR) images. Perfusion parameters, including arterial blood flow (AF), blood volume, and permeability surface (PS), were measured by two radiologists, using interclass correlation coefficient to evaluate the interobserver reliability. The difference of tumor size and perfusion data was analyzed by paired t test and rank sum test. The correlation of perfusion parameters with some factors was analyzed by Pearson or Spearman correlation analysis. RESULTS: Tumor sizes were not significantly different between vCTP and MR images. The interclass correlation coefficient of each parameter was 0.818-0.945. The AF value of CSC was significantly higher than normal uterine body, and the blood volume and PS values of CSC were not statistically different compared with those of normal uterine body. There was no significant difference in AF value of CSC among different FIGO stages and pathological grades. The AF and PS values of CSC were negatively correlated with the age of the patients. CONCLUSION: The vCTP could accurately shows the size of the CSC with use of MR as the reference standard, and its perfusion parameters have good measurement stability; the CSC was hypervascular, but this trend was less pronounced in older women.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Multidetector/métodos , Imagen de Perfusión/métodos , Neoplasias del Cuello Uterino/diagnóstico , Adulto , Anciano , Carcinoma de Células Escamosas/irrigación sanguínea , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Neoplasias del Cuello Uterino/irrigación sanguínea
17.
Taiwan J Obstet Gynecol ; 57(1): 32-39, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29458900

RESUMEN

OBJECTIVE: To evaluate inter-observer variability and reproducibility of ultrasound measurements for fetal biometric parameters. MATERIALS AND METHODS: A prospective cohort study was implemented in two tertiary care hospitals in Amman, Jordan; Prince Hamza Hospital and Albashir Hospital. 192 women with a singleton pregnancy at a gestational age of 18-36 weeks were the participants in the study. Transabdominal scans for fetal biometric parameter measurement were performed on study participants from the period of November 2014 to March 2015. Women who agreed to participate in the study were administered two ultrasound scans for head circumference, abdominal circumference and femur length. The correlation coefficient was calculated. Bland-Altman plots were used to analyze the degree of measurement agreement between observers. Limits of agreement ± 2 SD for the differences in fetal biometry measurements in proportions of the mean of the measurements were derived. Main outcome measures examine the reproducibility of fetal biometric measurements by different observers. RESULTS: High inter-observer inter-class correlation coefficient (ICC) was found for femur length (0.990) and abdominal circumference (0.996) where Bland-Altman plots showed high degrees of agreement. The highest degrees of agreement were noted in the measurement of abdominal circumference followed by head circumference. The lowest degree of agreement was found for femur length measurement. We used a paired-sample t-test and found that the mean difference between duplicate measurements was not significant (P > 0.05). CONCLUSION: Biometric fetal parameter measurements may be reproducible by different operators in the clinical setting with similar results. Fetal head circumference, abdominal circumference and femur length were highly reproducible. Large organized studies are needed to ensure accurate fetal measurements due to the important clinical implications of inaccurate measurements.


Asunto(s)
Biometría/métodos , Variaciones Dependientes del Observador , Ultrasonografía Prenatal/métodos , Adolescente , Adulto , Estudios de Cohortes , Femenino , Feto/diagnóstico por imagen , Humanos , Jordania , Embarazo , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
18.
Neuroimage Clin ; 16: 557-563, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28971007

RESUMEN

The cardinal movement abnormalities of Parkinson's disease (PD), including tremor, muscle rigidity, and reduced speed and frequency of movements, are caused by degeneration of dopaminergic neurons in the substantia nigra that project to the putamen, compromising information flow through frontal-subcortical circuits. Typically, the nigrostriatal pathway is more severely affected on the side of the brain opposite (contralateral) to the side of the body that manifests initial symptoms. Several studies have suggested that PD is also associated with changes in white matter microstructural integrity. The goal of the present study was to further develop methods for measuring striatonigral connectivity differences between PD patients and age-matched controls using diffusion weighted magnetic resonance imaging (MRI). In this cross-sectional study, 40 PD patients and 44 controls underwent diffusion weighted imaging (DWI) using a 40-direction MRI sequence as well as an optimized 60-direction sequence with overlapping slices. Regions of interest (ROIs) encompassing the putamen and substantia nigra were hand drawn in the space of the 40-direction data using high-contrast structural images and then coregistered to the 60-direction data. Probabilistic tractography was performed in the native space of each dataset by seeding the putamen ROI with an ipsilateral substantia nigra classification target. The effect of disease group (PD versus control) on mean putamen-SN connection probability and streamline density were then analyzed using generalized linear models controlling for age, gender, education, as well as seed and target region characteristics. Mean putamen-SN streamline density was lower in PD on both sides of the brain and in both 40- and 60-direction data. The optimized sequence provided a greater separation between PD and control means; however, individual values overlapped between groups. The 60-direction data also yielded mean connection probability values either trending (ipsilateral) or significantly (contralateral) lower in the PD group. There were minor between-group differences in average diffusion measures within the substantia nigra ROIs that did not affect the results of the GLM analyses when included as covariates. Based on these results, we conclude that mean striatonigral structural connectivity differs between PD and control groups and that use of an optimized 60-direction DWI sequence with overlapping slices increases the sensitivity of the technique to putative disease-related differences. However, overlap in individual values between disease groups limits its use as a classifier.


Asunto(s)
Imagen de Difusión Tensora/métodos , Vías Nerviosas/patología , Enfermedad de Parkinson/patología , Putamen/patología , Sustancia Negra/patología , Anciano , Estudios Transversales , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad
19.
J Neurosurg Pediatr ; 19(4): 479-489, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28156213

RESUMEN

OBJECTIVE Single-suture craniosynostosis (SSC), the premature fusion of a cranial suture, is characterized by dysmorphology of the craniofacial skeleton. Evidence to suggest that children with SSC are at an elevated risk of mild to moderate developmental delays and neurocognitive deficits is mounting, but the associations among premature suture fusion, neuroanatomy, and neurocognition are unexplained. The goals of this study were to determine 1) whether differences in the brain are present in young children with the 2 most common forms of SSC (sagittal and metopic) several years following surgical correction, and 2) whether the pattern of differences varies by affected suture (sagittal or metopic). Examination of differences in the brains of children with SSC several years after surgery may illuminate the growth trajectory of the brain after the potential constraint of the dysmorphic cranium has been relieved. METHODS The authors compared quantitative measures of the brain acquired from MR images obtained from children with sagittal or metopic craniosynostosis (n = 36) at 7 years of age to those obtained from a group of unaffected controls (n = 27) at the same age. The authors measured the volumes of the whole brain, cerebral cortex, cerebral white matter, cerebral cortex by lobe, and ventricles. Additionally, they measured the midsagittal area of the corpus callosum and its segments and of the cerebellar vermis and its component lobules. Measurements obtained from children with SSC and controls were compared using linear regression models. RESULTS No volume measures of the cerebrum or of the whole brain differed significantly between patients with SSC and controls (p > 0.05). However, ventricle volume was significantly increased in patients with SSC (p = 0.001), particularly in those with sagittal craniosynostosis (p < 0.001). In contrast, the area of the corpus callosum was significantly reduced in patients with metopic synostosis (p = 0.04), particularly in the posterior segments (p = 0.004). Similarly, the area of lobules VI-VII of the cerebellar vermis was reduced in patients with SSC (p = 0.03), with those with metopic craniosynostosis showing the greatest reduction (p = 0.01). CONCLUSIONS The lack of differences in overall brain size or regional differences in the size of the lobes of the cerebrum in children with metopic and sagittal synostosis suggests that the elevated risk of neurodevelopmental deficits is not likely to be associated with differences in the cerebral cortex. Instead, this study showed localized differences between sagittal and metopic craniosynostosis cases as compared with controls in the ventricles and in the midsagittal structures of the corpus callosum and the cerebellum. It remains to be tested whether these structural differences are associated with the increased risk for developmental delay and neurocognitive deficits in children with SSC.


Asunto(s)
Encéfalo/diagnóstico por imagen , Suturas Craneales/anomalías , Craneosinostosis/complicaciones , Craneosinostosis/diagnóstico por imagen , Discapacidades del Desarrollo/etiología , Suturas , Encéfalo/patología , Niño , Suturas Craneales/cirugía , Craneosinostosis/cirugía , Discapacidades del Desarrollo/cirugía , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Pruebas Neuropsicológicas
20.
J Neurosurg ; 127(1): 32-35, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27767400

RESUMEN

OBJECTIVE Blunt traumatic cerebrovascular injury (TCVI) represents structural injury to a vessel due to high-energy trauma. The Biffl Scale is a widely accepted grading scheme for these injuries that was developed using digital subtraction angiography. In recent years, screening CT angiography (CTA) has been used to identify patients with TCVI. The reliability of this scale, with injuries assessed using CTA, has not yet been determined. METHODS Seven independent raters, including 2 neurosurgeons, 2 neuroradiologists, 2 neurosurgical residents, and 1 neurosurgical vascular fellow, independently reviewed each presenting CTA of the neck performed in 40 patients with confirmed TCVI and assigned a Biffl grade. Ten images were repeated to assess intrarater reliability, for a total of 50 CTAs. Fleiss' multirater kappa (κ) and interclass correlation were calculated as a measure of interrater reliability. Weighted Cohen's κ was used to assess intrarater reliability. RESULTS Fleiss' multirater κ was 0.65 (95% CI 0.61-0.69), indicating substantial agreement as to the Biffl grade assignment among the 7 raters. Interclass correlation was 0.82, demonstrating excellent agreement among the raters. Intrarater reliability was perfect (weighted Cohen's κ = 1) in 2 raters, and near perfect (weighted Cohen's κ > 0.8) in the remaining 5 raters. CONCLUSIONS Grading of TCVI with CTA using the Biffl Scale is reliable.


Asunto(s)
Traumatismos Cerebrovasculares/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Puntaje de Gravedad del Traumatismo , Heridas no Penetrantes/diagnóstico por imagen , Traumatismos Cerebrovasculares/complicaciones , Humanos , Variaciones Dependientes del Observador , Estudios Prospectivos , Reproducibilidad de los Resultados , Heridas no Penetrantes/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA