Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 367
Filtrar
Más filtros











Intervalo de año de publicación
1.
Luminescence ; 39(9): e4889, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39223967

RESUMEN

Based on novel phosphorus-doped carbon dots (PCDs), a simple, quick, and accurate fluorescence probe for sarecycline (SAR) determination has been created. The PCDs were prepared in just five minutes using green, straightforward one-step microwave pyrolysis. To create the PCD probe, sodium phosphate monobasic was utilized as a phosphorus dopant and citric acid as a carbon supply. The proposed synthesis method was energy efficient and yielded CDs with a narrow particle size distribution. Based on inner-filter effect mechanism, the generated PCDs were used as nano-probe for SAR determination. The fluorescence quenching intensity showed a strong linear relationship with SAR concentration in the 3-90-µM range with a detection limit of 0.88 µM. Because there is no surface alteration of the CDs or creation of a covalent bond between SAR and PCDs, the developed approach is quick, easy, inexpensive, and requires less time. The new probe's enhanced sensitivity, broad linear range, and acceptable selectivity made it suitable for SAR measurement in pharmaceutical formulations and spiked human plasma. Most importantly, the Green Analytical Procedure Index (GAPI) and Analytical GREEnness (AGREE) assessments showed that the suggested method was environmentally friendly.


Asunto(s)
Carbono , Fósforo , Puntos Cuánticos , Carbono/química , Humanos , Fósforo/química , Puntos Cuánticos/química , Colorantes Fluorescentes/química , Tetraciclinas/análisis , Tetraciclinas/sangre , Espectrometría de Fluorescencia , Tamaño de la Partícula , Formas de Dosificación , Límite de Detección
2.
Anal Chim Acta ; 1325: 343090, 2024 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-39244300

RESUMEN

BACKGROUND: Curcumin has been used in traditional medicine because of its pharmacological activity, including antioxidant, antibacterial, anticancer, and anticarcinogenic properties. Therefore, sensitive and selective monitoring of curcumin is highly demand for practical application. RESULTS: In this study, we describe the construction of a fluorescence method for curcumin assay based on nitrogen-doped MoS2 quantum dots (N-MoS2 QDs). The N-MoS2 QDs are constructed by a solvothermal method using sodium molybdate and Cys as precursors. With the addition of curcumin, the bright blue fluorescence of N-MoS2 QDs is quenched by the inner filter effect (IFE). The QDs emitted bright blue fluorescence and could be quenched by the addition of curcumin via IFE. The dynamic range is the range of 0.1-10 µM for curcumin detection, with a detection limit of 59 nM. N-MoS2 QDs were applied for curcumin assay in real samples with good recovery. In addition, the N-MoS2 QDs exhibited relative low cytotoxicity and could be applied for fluorescence-based imaging in biological samples. SIGNIFICANCE: Our study indicates that the sensor possesses good selectivity to monitor curcumin in water samples, human urine samples, ginger powder samples, mustard samples, and curry samples with satisfactory recoveries. The N-MoS2 QDs possess less cytotoxicity with excellent biocompatibility and were applied for in vitro cell imaging.


Asunto(s)
Curcumina , Disulfuros , Colorantes Fluorescentes , Molibdeno , Nitrógeno , Puntos Cuánticos , Curcumina/química , Curcumina/farmacología , Puntos Cuánticos/química , Molibdeno/química , Humanos , Disulfuros/química , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Nitrógeno/química , Imagen Óptica , Límite de Detección , Espectrometría de Fluorescencia , Supervivencia Celular/efectos de los fármacos
3.
ACS Appl Bio Mater ; 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39267591

RESUMEN

The abnormally high level of bilirubin (BR) in biofluids (human serum and urine) indicates a high probability of jaundice and liver dysfunction. However, quantification of BR as the Jaundice biomarker is difficult due to the interference of various biomolecules in serum and urine. To address this issue, we developed a fluorescence-based detection strategy, for which yellow emissive carbon dots (YCDs) were produced from a one-step solvothermal process using phloroglucinol and thionin acetate as chemical precursors. The as-fabricated YCDs exhibited a strong fluorescence peak at the wavelength of 542 nm upon excitation at 390 nm. We used YCDs for detecting BR through the fluorescence turn-off mechanism, unveiling the excellent sensitivity in the linear range of 0.5-12.5 µM with a limit of detection (LOD) of 9.62 nM, which was far below the clinically relevant range. The analytical nanoprobe also offered excellent detection specificity for quantifying BR in real samples. Moreover, the biocompatible fluorescent nanoprobe was successfully employed to target mitochondria in live cancer cells. A colocalization study confirmed that YCDs possessed the ability to target mitochondria and overlapped completely with MitoTracker Red. The developed nanoprobe of YCDs turned out to be straightforward in their synthesis, noninvasive, and can be utilized for biomedical sensors to diagnose the onset of jaundice as well as for mitochondria targeting.

4.
Luminescence ; 39(8): e4846, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39090987

RESUMEN

Antibiotic residues persist in the environment and represent serious health hazards; thus, it is important to develop sensitive and effective detection techniques. This paper presents a bio-inspired way to make water-soluble fluorescent polymer carbon dots (PCDs@PVA) by heating biomass precursors and polyvinyl alcohol (PVA) together. For example, the synthesized PCDs@PVA are very stable with enhanced emission intensity. This property was observed in a wide range of environmental conditions, including those with changing temperatures, pH levels, UV light, and ionic strength. PCDs@PVA detected the antibiotic chlortetracycline (CTCs) with great selectivity against structurally related compounds and a low detection limit of 20 nM, demonstrating outstanding sensitivity and specificity. We confirmed the sensor's practical application through real sample analysis, yielding recovery rates of 98%-99% in samples of milk, honey, and river water. The synthesized PCDs@PVA fluorescence sensor was successfully used for CTCs detection in real samples.


Asunto(s)
Carbono , Clortetraciclina , Colorantes Fluorescentes , Alcohol Polivinílico , Puntos Cuánticos , Clortetraciclina/análisis , Alcohol Polivinílico/química , Carbono/química , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Puntos Cuánticos/química , Animales , Leche/química , Antibacterianos/análisis , Antibacterianos/química , Antibacterianos/síntesis química , Límite de Detección , Miel/análisis , Polímeros/química , Polímeros/síntesis química , Contaminantes Químicos del Agua/análisis , Ríos/química , Espectrometría de Fluorescencia , Concentración de Iones de Hidrógeno
5.
Heliyon ; 10(14): e34611, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39114008

RESUMEN

Zolbetuximab (ZOL) is a groundbreaking monoclonal antibody targeting CLDN 18.2, a cancer cell surface protein. It is a first-in-class therapy for gastric and gastroesophageal junction adenocarcinoma. However, there is currently any immunoassay available for bioanalysis of ZOL, hindering its pharmacokinetic studies, therapeutic monitoring, and safety profile refinement. To address this gap, this study presents the development and validation of a novel highly sensitive inner filter effect-based fluorescence immunoassay (IFE-FIA) with quantum dots (QDs) as a probe. This assay enables the quantitative determination of ZOL in plasma samples. The assay involved non-competitive capturing of ZOL from the samples using a specific antigen (CLDN 18.2 protein) immobilized on assay plate microwells. A horseradish peroxidase (HRP)-labelled anti-human IgG was used to measure the immune complex. The assay's detection system relies on the formation of a light-absorbing colored product through an HRP-catalyzed oxidative reaction with the substrate 3,3',5,5'-tetramethylbenzidine. This light absorption efficiently quenched the fluorescence of QDs via the IFE. The measured fluorescence signals corresponded to the concentrations of ZOL in the samples. The conditions of the IFE-FIA and its detection system were refined, and the optimum procedures were established. Following the guidelines of immunoassay validation for bioanalysis, the assay was validated, and all the validation criteria were acceptable. The assay demonstrates high sensitivity, accurately quantifying ZOL at concentrations as low as 10 ng/mL in plasma samples, with acceptable precision. Importantly, it avoids interferences from endogenous substances and plasma matrix. The recoveries in spiked human plasma ranged from 96.8 % to 104.5 %, with relative standard deviations of 4.1 %-6.5 %. The proposed IFE-FIA represents a valuable tool for quantifying ZOL in clinical settings, enabling assessment of its pharmacokinetics, therapeutic drug monitoring, and safety profile refinement.

6.
Materials (Basel) ; 17(16)2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39203099

RESUMEN

In this work, we demonstrated a novel, sensitive and effective fluorescent naringin (NRG) and naringenin (NRGe) detection method using polymethionine nanoparticles (PMNPs) as a fluorescent nanoprobe. The PMNPs were first synthesized by autopolymerization of methionine at 90 °C when trace copper ions existed. The as-prepared PMNPs were thoroughly characterized by transmission electron microscopy (TEM), Fourier-transform infrared spectroscopy (FT-IR), gel permeation chromatograph (GPC), nuclear magnetic resonance spectroscopy (NMR), transient and steady-state fluorescence and UV-Vis absorption spectroscopy. The quenching mechanism was attributed to the inner filter effect (IFE). Moreover, the developed assay was used successfully to detect NRG and NRGe in real samples of citrus fruits, illustrating that this detection method has great potential application in the field of citrus fruits analysis.

7.
Chemosphere ; 362: 142863, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39019172

RESUMEN

Tetracycline (TC) is extensively utilized in livestock breeding, aquaculture, and medical industry. TC residues seriously harm food security, the environment, and human health. There is an urgent need to exploit a highly efficient and sensitive testing method to monitor TC residue levels in aquatic environments. In this study, graphitic carbon nitride quantum dots (g-CNQDs) were successfully synthesized by a one-step microwave-assisted method using citric acid and urea as precursors. The as-prepared g-CNQDs with size of 1.25-3.75 nm exhibited bright yellow fluorescence at 523 nm when excited at 397 nm. Interestingly, this characteristic fluorescence emission of g-CNQDs could be selectively and efficiently quenched by TC. Based on this phenomenon, for TC detection was successfully explored and applied in real water samples. Wide linear scope of 7-100 µM, low detection limit (LOD) of 0.48 µM, satisfactory recovery of 97.77%-103.4%, and good relative standard deviation (RSD) of 1.05-5.87% were obtained. Mechanism investigations revealed that the static quenching and the inner filter effect (IFE) were responsible for this fluorescence quenching between g-CNQDs and TC. This work not only provided a facile approach for g-CNQDs synthesis but also constructed a g-CNQDs-based fluorescent sensor platform for the highly sensitive and selective detection of TC in aquatic environments.


Asunto(s)
Grafito , Límite de Detección , Microondas , Compuestos de Nitrógeno , Puntos Cuánticos , Tetraciclina , Contaminantes Químicos del Agua , Puntos Cuánticos/química , Grafito/química , Contaminantes Químicos del Agua/análisis , Tetraciclina/análisis , Tetraciclina/química , Compuestos de Nitrógeno/química , Fluorescencia , Espectrometría de Fluorescencia , Nitrilos/química , Nitrilos/análisis , Colorantes Fluorescentes/química
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 322: 124805, 2024 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-39003827

RESUMEN

A novel fluorimetric ratiometric probe of green and eco-friendily nitrogen-enriched, oxygen-doped carbon nanodots (Cnanodots) was prepared for the quantitative analysis of mercury(II) (HgII) and nitrofurantoin (Nit) in the environmental sewage. The Cnanodots exhibits dual-emission peaks respectively at 345 and 445 nm under 285 nm excitation, with excitation-independent properties. Unexpectedly, this Cnanodots displays two obvious ratiometric responses to HgII and Nit through decreasing the signal at 345 nm and remaining invariable at 445 nm. Experimental results confirm that the highly sensitive analysis of HgII and Nit are achieved respectively based on matching energy-level electron transfer and inner filter effect mechanisms. The fluorescence (FL) ratiometric intensity of [FL345nm/FL445nm] expresses a good linear relationship with the concentration of HgII in the scope of 0.01-20 µM, while the logarithm of [Log(FL0345nm-FL345nm)] on the quenching degree of the probe by Nit also shows a good linear correlation within the range of 0.01-100 µM. The detection limits were calculated to be 4.14 nM for HgII, and 7.84 nM for Nit. Moreover, recovery experiments of Cnanodots for HgII and Nit sensing in real sewage samples obtained satisfactory results, comfirming the feasibility of practical application.

9.
Food Chem ; 458: 140304, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38970961

RESUMEN

Protecting human health and ensuring food security require the swift and accurate detection of sulfonamides (SAs) residues in foods. Herein, we proposed an Eu-postfunctionalized bimetallic porphyrin metal-organic framework (PCN-221(Zr/Ce)@Eu-DPA-H4btec) synthesized solvothermally for fluorescence sensing. The PCN-221(Zr/Ce)@Eu-DPA-H4btec fluorescent sensor demonstrated excellent stability and high selectivity to SAs, and the detection limits of sulfamethazine (SM2), sulfamerazine (SMR), and sulfamethoxydiazine (SMD) were as low as 56 nmol/L, 45 nmol/L, and 56 nmol/L, respectively. The PCN-221(Zr/Ce)@Eu-DPA-H4btec fluorescent sensor was successfully applied for the detection of SM2, SMR, and SMD in real pork and milk samples, with satisfactory recoveries (81.2-118.3%) and high precisions (RSDs <8.2, n = 3). Combining the optical properties of the nanohybrids, PCN-221(Zr/Ce)@Eu-DPA-H4btec integrated fluorescent hydrogels were innovatively prepared for visual sensing of SM2, SMR, and SMD. This study provides an uncomplicated and sensitive method for SAs detection in food matrices.


Asunto(s)
Europio , Contaminación de Alimentos , Hidrogeles , Estructuras Metalorgánicas , Leche , Porfirinas , Espectrometría de Fluorescencia , Sulfonamidas , Estructuras Metalorgánicas/química , Contaminación de Alimentos/análisis , Europio/química , Leche/química , Animales , Sulfonamidas/química , Sulfonamidas/análisis , Porfirinas/química , Hidrogeles/química , Porcinos , Fluorescencia , Límite de Detección , Colorantes Fluorescentes/química
10.
Mikrochim Acta ; 191(8): 461, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38990273

RESUMEN

Three phenomena, namely coordination-induced emission (CIE), aggregation-induced emission (AIE), and inner filter effect (IFE), were incorporated into the design of a ratiometric and color tonality-based biosensor. Blue fluorescent Al-based metal-organic frameworks (FMIL-96) were prepared from non-emissive ligand and aluminum ions via CIE. Interestingly, the addition of tetracycline (TC) led to ratiometric detection and color tonality, as the blue emission at 380 nm was quenched (when excited at 350 nm) due to IFE, while the green-yellowish emission at 525 nm was enhanced due to AIE. Based on that, an ultra-sensitive visual-based color tonality mode with smartphone assistance was developed for detection of TC. The sensor exhibited a linear relationship within a broad range of 2.0 to 85.0 µM TC with a detection limit of 68.0 nM. TC in milk samples was quantified with high accuracy and precision. This integration of smartphone and visual fluorescence in solution is accurate, reliable, cost-effective, and time-saving, providing an alternative strategy for the semi-quantitative determination of TC on-site.

11.
Spectrochim Acta A Mol Biomol Spectrosc ; 321: 124729, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38955073

RESUMEN

There is an urgent requirement for the development of sensitive and quick sensors to monitor chromium (VI) due to its substantial carcinogenic and mutagenic properties. A coexisting system of coumarin 334 and diphenylcarbazide (C334/DPC) was used in this study as a fluorescent chemosensor to detect Cr(VI) ions. Upon the addition of Cr(VI), a purple chelate complex (Cr(III)-diphenylcarbazone) was produced, which resulted from the quantitative reaction between Cr(VI) ions and diphenylcarbazide (DPC), whereas no interaction between Cr(VI) and coumarin 334 took place. More interestingly, the absorption spectra of purple (Cr(III)-diphenylcarbazone) complex (λmax = 540 nm) were overlapped with emission and excitation spectra of coumarin 334 (λex/em = 453/492), resulting in the efficient quenching of coumarin 334 (C334) via the inner filter effect. Furthermore, the semi-quantitative estimation of Cr(VI) ion concentration may be achieved by visually watching the progressive color transformation of the probe from yellow to red after the addition different concentration of Cr(VI). The calibration plot for determination of Cr(VI) by this method is ranging from 0.048 to 268 µM. DFT calculations were conducted to enrich our understanding about the mechanism of action. This approach demonstrates an excellent selectivity and sensitivity for Cr(VI) including a detection limit of 48 nM. The new sensor was successfully applied to water samples (tap, mineral, and waste waters). The accuracy was confirmed by the atomic absorption spectroscopy.

12.
Eur J Pharm Biopharm ; 201: 114377, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38955284

RESUMEN

Drug product development of therapeutic antibody formulations is still dictated by the risk of protein particle formation during processing or storage, which can lead to loss of potency and potential immunogenic reactions. Since structural perturbations are the main driver for irreversible protein aggregation, the conformational integrity of antibodies should be closely monitored. The present study evaluated the applicability of a plate reader-based high throughput method for Intrinsic Tryptophan Fluorescence Emission (ITFE) spectroscopy to detect protein aggregation due to protein unfolding in high-concentrated therapeutic antibody samples. The impact of fluorophore concentration on the ITFE signal in microplate readers was investigated by analysis of dilution series of two therapeutic antibodies and pure tryptophan. At low antibody concentrations (< 5 mg/mL, equivalent to 0.8 mM tryptophan), the low inner filter effect suggests a quasi-linear relationship between antibody concentration and ITFE intensity. In contrast, the constant ITFE intensity at high protein concentrations (> 40 mg/mL, equivalent to 6.1 mM tryptophan) indicate that ITFE spectroscopy measurements of IgG1 antibodies are feasible in therapeutically relevant concentrations (up to 223 mg/mL). Furthermore, the capability of the method to detect low levels of unfolding (around 1 %) was confirmed by limit of detection (LOD) determination with temperature-stressed antibody samples as degradation standards. Change of fluorescence intensity at the maximum (ΔIaM) was identified as sensitive descriptor for protein degradation, providing the lowest LOD values. The results demonstrate that ITFE spectroscopy performed in a microplate reader is a valuable tool for high-throughput monitoring of protein degradation in therapeutic antibody formulations.


Asunto(s)
Inmunoglobulina G , Espectrometría de Fluorescencia , Triptófano , Triptófano/química , Espectrometría de Fluorescencia/métodos , Inmunoglobulina G/química , Agregado de Proteínas , Desplegamiento Proteico , Anticuerpos Monoclonales/química , Ensayos Analíticos de Alto Rendimiento/métodos , Soluciones
13.
Methods Appl Fluoresc ; 12(4)2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-38955337

RESUMEN

Continuous in-line detection and process monitoring are essential for industrial, analytical, and biomedical applications. Lightweight, highly flexible, and low-cost fiber optics enable the construction of compact and robust hand-held devices forin situchemical and biological species analysis in both industrial and biomedicalin vitro/in vivodetection. Despite the broad range of fiber-optic based applications, we lack a good understanding of the parameters that govern the efficiency of light collection or the sensitivity of detection. Consequently, comparing samples of different optical density and/or geometry becomes challenging and can lead to misinterpretation of results; especially when we lack the approaches necessary to correct the detected signal (spectra) for artifacts such as inner-filter effect or scattering. Hence, in this work, we discuss factors affecting the signal detected by the fiber optic in the bare and lens-coupled flat-tipped configurations that lead to signal/spectral distortions. We also present a simple generic model describing the excitation profile and emission collection efficiency that we verify with experimental data. Understanding the principles governing the signal collected by the fiber will provide rationales for correcting the measured emission spectra and recovering the true emission profile of optically dense samples.

14.
Talanta ; 278: 126432, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38917547

RESUMEN

Given the threat to human health posed by the abuse of tetracycline (TC), the development of a portable, on-site methods for highly sensitive and rapid TC detection is crucial. In this work, we initially synthesized europium-doped silicon nanoparticles (SiEuNPs) through a facile one-pot microwave-assisted method. Due to its blue-red dual fluorescence emission (465 nm/621 nm), which was respectively attributed to the silicon nanoparticles and Eu3+, SiEuNPs were designed as a ratiometric fluorescent sensor for TC detection. For the dual-signal reverse response mechanism: TC quenched the blue emission from silicon nanoparticles through inner filter effect (IFE), and enhanced the red emission through "antenna effect" (AE) between TC and Eu3+, the nanoprobe was able to detect TC within a range of 0.2-10 µM with a limit of detection (LOD) of 10.7 nM. Notably, the equilibrium detection time was only 1 min, achieving rapid TC detection. Furthermore, TC was also measured in real samples (tap water, milk and honey) with recoveries ranging from 95.7 % to 117.0 %. More importantly, a portable smartphone-assisted on-site detection platform was developed, enabling real-time qualitative identification and semi-quantitative analysis of TC based on fluorescence color changes. This work not only provided a novel doped silicon nanoparticles strategy, but also constructed a ratiometric sensing platform with dual-signal reverse response for intuitive and real-time TC detection.


Asunto(s)
Europio , Colorantes Fluorescentes , Nanopartículas , Silicio , Teléfono Inteligente , Tetraciclina , Europio/química , Silicio/química , Nanopartículas/química , Tetraciclina/análisis , Colorantes Fluorescentes/química , Leche/química , Animales , Espectrometría de Fluorescencia/métodos , Miel/análisis , Límite de Detección , Imagen Óptica , Contaminantes Químicos del Agua/análisis
15.
Spectrochim Acta A Mol Biomol Spectrosc ; 321: 124708, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38936210

RESUMEN

Copper nanoclusters (FA@CuNCs) emitting blue fluorescence were successfully developed via a one-pot technique. In this method, the copper chloride, folic acid and hydrazine hydrate were applied as a precursor, protective agent and reducing agent, respectively. The absorption, fluorescence excitation and emission spectra of FA@CuNCs were carried out by using ultraviolet-visible and fluorescence spectrometry, respectively. The morphology, particle size, functional groups, oxidation states of elements of FA@CuNCs were discussed via using transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and X-ray photoelectron spectroscopy (XPS). The stability of FA@CuNCs was studied under various conditions, such as storage time at 25 ℃, ultraviolet radiation time, sodium chloride solutione and pH. The FA@CuNCs displayed blue fluorescence under the excitation wavelength of 361 nm, and the fluorescence quantum yield was 7.45 %. As a result of the inner filter effect, the alizarin red could significantly weaken the blue fluorescence of FA@CuNCs. Thus, the as-prepared FA@CuNCs could be utilized as fluorescence nanosensors for the trace determination of alizarin red. This platform suggested an excellent linear range for alizarin red varying from 0.5 to 200 µM with a fitting coefficient of 0.9955. The detection limit was calculated to be 0.064 µM in the light of the 3b/k (b and k refer to the standard deviation and slope of fitted curve, respectively). Furthermore, the as-developed FA@CuNCs could be used to detect the alizarin red in real samples and for the sensing of temperature.

16.
Talanta ; 277: 126335, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38823323

RESUMEN

Developing a simple, economical, sensitive, and selective method for label-free direct detection analytes is attractive, especially the strategies that could achieve signal amplification without complicated operations. Herein, a dual-fluorescence colorimetric nanoswitch sensing platform for label-free direct melamine (MEL) detection was established. We first explored the relationship between MEL-induced aggregation of gold nanoparticles (AuNPs) and size and determined the optimal size to be 37 nm. Using surfactant Triton X-100 to modify AuNPs and clarify possible interaction mechanisms to improve detection performance. The dynamic changes of surface plasmon resonance absorption peaks in the dispersed and aggregated states of AuNPs were skillfully utilized to match the emission of multicolor gold nanoclusters to trigger the multi-inner filter effect. Accompanied by the addition of MEL-induced AuNPs to change from dispersed to aggregated state, the fluorescence of green-emitting and red-emitting gradually turned on and turned off, respectively. The fluorescence turn-on mode detection limit was 10 times higher than the colorimetric method and as low as 5.5 ng/mL; the detection took only 10 min. The sensor detected MEL in spiked milk samples with a good recovery in the range of 81.2-111.0 % with a coefficient of variation less than 11.4 % and achieved a good correlation with commercial kits. The proposed sensor integrates numerous merits of label-free, multi-signal readout, self-calibration, simple operations, and economical, which provides a promising tool for convenient on-site detection of MEL.


Asunto(s)
Colorimetría , Oro , Nanopartículas del Metal , Leche , Triazinas , Triazinas/análisis , Triazinas/química , Oro/química , Nanopartículas del Metal/química , Colorimetría/métodos , Leche/química , Animales , Límite de Detección , Fluorescencia , Contaminación de Alimentos/análisis , Espectrometría de Fluorescencia/métodos
17.
Chem Biodivers ; 21(8): e202400891, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38825847

RESUMEN

The utilization of natural materials for the synthesis of highly fluorescent carbon quantum dots (CQDs) presents a sustainable approach to overcome the challenges associated with traditional chemical precursors. Here, we report the synthesis of novel S,N-self-doped CQDs (S,N@CQDs) derived from asparagus officinalis herb. These S,N@CQDs exhibit 16.7 % fluorescence quantum yield, demonstrating their potential in medical diagnostics. We demonstrate the efficacy of S,N@CQDs as luminescent probes for the detection of anti-pathogenic medications metronidazole (MTZ) and nitazoxanide (NTZ) over concentration ranges of 0.0-180.0 µM (with a limit of detection (LOD) of 0.064 µM) and 0.25-40.0 µM (LOD of 0.05 µM), respectively. The probes were successfully applied to determine MTZ and NTZ in medicinal samples, real samples, and spiked human plasma, with excellent recovery rates ranging from 99.82 % to 103.03 %. Additionally, S,N@CQDs demonstrate exceptional efficacy as diagnostic luminescent probes for hemoglobin (Hb) detection over a concentration range of 0-900 nM, with a minimal detectability of 9.24 nM, comparable to commercially available medical laboratory diagnostic tests. The eco-friendly synthesis and precise detection limits of S,N@CQDs meet necessary analytical requirements and hold promise for advancing diagnostic capabilities in clinical settings. This research signifies a significant step towards sustainable and efficient fluorescence-based medical diagnostics.


Asunto(s)
Asparagus , Carbono , Puntos Cuánticos , Puntos Cuánticos/química , Carbono/química , Humanos , Asparagus/química , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Metronidazol/análisis , Metronidazol/sangre , Metronidazol/química , Hemoglobinas/análisis , Límite de Detección
18.
Food Chem X ; 22: 101488, 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-38840721

RESUMEN

Developing a rapid detection method of Cr(VI) and ascorbic acid (AA) is vital in the food and environmental fields. Herein, an anthrylimidazole-based fluorescent ionic liquid (AI-FIL) with the advantageous fluorescent properties was successfully prepared and used to construct a promising "on-off-on" fluoroprobe for rapid/sensitive Cr(VI) and AA detection. Cr(VI) could effectively quench the fluorescence of AI-FIL owing to the inner-filter effect and photoinduced electron-transfer process. However, the decreased fluorescence could be rapidly recovered by AA owing to the redox reaction between AA and Cr(VI). For Cr(VI) detection, a satisfactorily linear response (0.03-300 µM) was achieved with the corresponding detection limit of 9 nM. For AA detection, a good linearity from 1 to 1000 µM was obtained with the resultant detection limit of 0.3 µM. Moreover, the AI-FIL based fluoroprobe was successfully utilized for Cr(VI) and AA detection in food and water samples with satisfactory accuracy and precision.

19.
J Fluoresc ; 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38874826

RESUMEN

Detection of nitroaromatic explosives is essential in the area of environmental safety. Fluorescent carbon nitride nanoparticles is a promising material for this purpose. Herein, we have prepared fluorescent carbon nitride nanoparticles (CNNPs) by one step thermal treatment of formamide. These fluorescent CNNPs is sensitive towards picric acid (PA) than other analytes both in aqueous medium and on test paper which is witnessed by fluorescence quenching based on inner filter effect (IFE). The PA detection with the fluorescent CNNPs is observed in the concentration ranges, 0 µM to 60 µM with linear range of 10 nM to 25 µM. The minimum detection limit in aqueous medium and solid phase are determined to be 26.20 nM and 10 µM respectively. Finally, the fluorescent CNNPs is applied for detection of PA in real water samples. The recoveries are in the ranges from 99.54 to 116.35% with relative standard deviation less than 3.85%. This proposed fluorescent method can act as suitable analytical technique to monitored PA concentration in water samples.

20.
Environ Technol ; : 1-12, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38887014

RESUMEN

2,4,6-Trinitrophenol (TNP) has high explosive risks and biological toxicity, and there has been considerable concern over the determination of TNP. In the present work, fluorescent carbon dots (CDs) stemmed from a green carbon source of pinecone by the facile hydrothermal approach. A novel environment- friendly fluorescent probe was developed to efficiently detect TNP by using the obtained CDs with remarkable fluorescence stability. The fluorescent CDs exhibited obvious excitation dependence with the highest peaks for excitation and emission occurring at 321 and 411 nm, respectively. The fluorescence intensity is significantly reduced by TNP owing to the inner filter effect with the CDs. The probe exhibited good linearity with TNP concentrations in the range of 0.025-20 µg mL-1, and the limit of detection was as low as 8.5 ng mL-1. Additionally, the probe proved successful in sensing TNP quantitatively in actual environmental samples with satisfied recoveries of 95.6-99.6%. The developed fluorescent probe offered an environment-friendly, efficient, rapid, and reliable platform for detecting trace TNP in the environmental field.HighlightsNovel carbon dots were synthesised from green precursors of pineal powder.The highly effective quenching process was put down to the inner filter effect.The as-constructed fluorescent probe was successfully utilised for sensing 2,4,6-trinitrophenol in environmental samples.The proposed method was simple, rapid, efficient, economical, and eco-friendly.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA