Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Idioma
Intervalo de año de publicación
1.
Ter Arkh ; 96(7): 675-682, 2024 Jul 30.
Artículo en Ruso | MEDLINE | ID: mdl-39106510

RESUMEN

AIM: To evaluate the efficacy and safety of the advanced technique for positioning the endocardial electrodes of a cardiac contractility modulation (CCM) device. MATERIALS AND METHODS: The CCM system was implanted in 100 patients, of which 60 CCM electrodes were positioned in the most optimal zones of myocardial perfusion, in particular, in the zone of the minor focal-scar/fibrotic lesion (the Summed Rest Score of 0 to 1-2, the intensity of the radiopharmaceutical at least 30%), and in 40 patients according to the standard procedure. Before the implantation of the CCM system, 60 patients underwent tomography (S-SPECT) of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest to determine the most optimal electrode positioning zones and 100 patients underwent transthoracic echocardiography at baseline and after 12 months to assess the effectiveness of surgical treatment. RESULTS: Improved ventricular electrode positioning technique is associated with the best reverse remodeling of the left ventricular myocardium, especially in patients with ischemic chronic heart failure, with less radiation exposure to the surgeon and the patient, and without electrode-related complications. CONCLUSION: At the preoperative stage, it is recommended to perform a synchronized single-photon emission computed tomography of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest before implantation of the CCM device to assess the presence of scar zones/myocardial fibrosis in the anterior and inferior septal regions of the interventricular septum of the left ventricle, followed by implantation of ventricular electrodes in the zone of the minor scar/fibrous lesion, which will allow to achieve optimal stimulation parameters, increase the effectiveness of CCM therapy, reduce the radiation exposure on medical personnel and the patient during surgery.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Masculino , Femenino , Persona de Mediana Edad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Fibrilación Atrial/cirugía , Anciano , Resultado del Tratamiento , Electrodos Implantados , Volumen Sistólico/fisiología , Tomografía Computarizada de Emisión de Fotón Único/métodos , Ecocardiografía/métodos , Contracción Miocárdica/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA