Arch Cardiovasc Dis ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39232887

RESUMEN

BACKGROUND: Although guidelines recommend screening patients for atrial fibrillation (AF) after stroke, the optimal timing and combination of screening tools remain unclear. AIMS: We evaluated the suitability of a sequential combination of screening techniques for AF detected after stroke (AFDAS). We also compared patient characteristics according to the timing of AFDAS. METHODS: Patients without previous AF admitted for acute ischaemic stroke were prospectively enrolled. After a stepwise screening approach for AFDAS based on electrocardiogram, telemetry monitoring and in-hospital long-term Holter, patients with cryptogenic stroke underwent implantation of an implantable cardiac monitor (ICM). Early AFDAS was defined as AF diagnosed during hospitalization and late AFDAS as AF diagnosed on an ICM. RESULTS: Of the 240 patients included, 104 (43.3%) had a documented cause of stroke not related to AF. Among the 136 remaining patients, AFDAS was detected in 82 (60.3%) during the acute screening phase or during the 3-year follow-up by ICM. Early AFDAS was diagnosed by ECG, telemetry and in-hospital long-term Holter monitoring in 17 (20.7%), 25 (30.5%) and 18 (22.0%) patients, respectively. Among 76 patients who had an ICM implanted for cryptogenic stroke, AF was detected in 22 patients (28.9%). Except for age and stroke location, patients with early AFDAS did not differ from those with late AFDAS, particularly with regard to the prevalence of atrial cardiomyopathy markers. CONCLUSION: A stepwise approach to AFDAS screening allows early detection of AF in a considerable number of patients during their hospitalization. ICMs remain complementary to non-invasive screening tools for the detection of remote episodes of AF.

3.
Pacing Clin Electrophysiol ; 47(8): 983-987, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38963722

RESUMEN

INTRODUCTION: Patients with Brugada syndrome (BrS) face an increased risk of ventricular arrhythmias and sudden cardiac death. Implantable cardiac monitors (ICMs) have emerged as effective tools for detecting arrhythmias in BrS. Technological advancements, including temperature sensors and improved subcutaneous electrocardiogram (subECG) signal quality, hold promise for further enhancing their utility in this population. METHODS AND RESULTS: We present a case of a 40-year-old man exhibiting a BrS type 2 pattern on 12-lead ECG, who underwent ICM insertion (BIOMONITOR IIIm, BIOTRONIK) due to drug-induced BrS type 1 pattern and a history of syncope, with a negative response to programmed ventricular stimulation. The device contains an integrated temperature sensor and can transmit daily vital data, such as mean heart rate and physical activity. Several months later, remote alerts indicated a temperature increase, along with transmitted subECGs suggesting a fever-induced BrS type 1 pattern. The patient was promptly advised to commence antipyretic therapy. Over the following days, remotely monitored parameters showed decreases in mean temperature, physical activity, and mean heart rate, without further recurrence of abnormal subECGs. CONCLUSION: ICMs offer valuable insights beyond arrhythmia detection in BrS. Early detection of fever using embedded temperature sensors may improve patient management, while continuous subECG morphological analysis has the potential to enhance risk stratification in BrS patients.


Asunto(s)
Síndrome de Brugada , Humanos , Síndrome de Brugada/fisiopatología , Masculino , Adulto , Electrocardiografía Ambulatoria/instrumentación , Temperatura Corporal , Tecnología de Sensores Remotos/instrumentación , Electrocardiografía , Diseño de Equipo
4.
Heart Rhythm ; 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38969049

RESUMEN

BACKGROUND: After a cryptogenic stroke, patients often will require prolonged cardiac monitoring; however, the subset of patients who would benefit from long-term rhythm monitoring is not clearly defined. OBJECTIVE: The purpose of this study was to create a risk score by identifying significant predictors of atrial fibrillation (AF) using age, sex, comorbidities, baseline 12-lead electrocardiogram, short-term rhythm monitoring, and echocardiographic data and to compare it to previously published risk scores. METHODS: Patients admitted to Montefiore Medical Center between May 2017 and June 2022 with a primary diagnosis of cryptogenic stroke or transient ischemic attack who underwent long-term rhythm monitoring with an implantable cardiac monitor were retrospectively analyzed. RESULTS: Variables positively associated with a diagnosis of clinically significant AF include age (P <.001), race (P = .022), diabetes status (P = .026), chronic obstructive pulmonary disease status (P = .012), presence of atrial runs (P = .003), number of atrial runs per 24 hours (P <.001), total number of atrial run beats per 24 hours (P <.001), number of beats in the longest atrial run (P <.001), left atrial enlargement (P = .007), and at least mild mitral regurgitation (P = .009). We created a risk stratification score for our population, termed the ACL score. The ACL score demonstrated superiority to the CHA2DS2-VASc score and comparability to the C2HEST score for predicting device-detected AF. CONCLUSION: The ACL score enables clinicians to better predict which patients are more likely to be diagnosed with device-detected AF after a cryptogenic stroke.

6.
Pflugers Arch ; 476(7): 1145-1154, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38703193

RESUMEN

Arrhythmia detection is essential when assessing the safety of novel drugs and therapies in preclinical studies. Many short-term arrhythmia monitoring methods exist, including non-invasive ECG and Holter. However, there are no reliable, long-term, non-invasive, or minimally invasive methods for cardiac arrhythmia follow-up in large animals that allows free movement with littermates. A long follow-up time is needed when estimating the impact of long-lasting drugs or therapies, such as gene therapy. We evaluated the feasibility and performance of insertable cardiac monitors (ICMs) in pigs for minimally invasive, long-term monitoring of cardiac arrhythmias that allows free movement and species-specific behavior. Multiple implantation sites were tested to assess signal quality. ICMs recognized reliably many different arrhythmias but failed to detect single extrasystoles. They also over-diagnosed T-waves, resulting in oversensing. Muscle activity and natural startles of the animals caused noise, leading to a heterogeneous signal requiring post-recording evaluation. In spite of these shortcomings, the ICMs showed to be very useful for minimally invasive long-term monitoring of cardiac rhythm in pigs.


Asunto(s)
Arritmias Cardíacas , Animales , Porcinos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Electrocardiografía/métodos , Electrocardiografía/instrumentación , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/veterinaria
7.
Front Cardiovasc Med ; 11: 1300074, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38807948

RESUMEN

Objectives: Cardiac arrhythmias predict poor outcome after myocardial infarction (MI). We studied if arrhythmia monitoring with an insertable cardiac monitor (ICM) can improve treatment and outcome. Design: BIO|GUARD-MI was a randomized, international open-label study with blinded outcome assessment. Setting: Tertiary care facilities monitored the arrhythmias, while the follow-up remained with primary care physicians. Participants: Patients after ST-elevation (STEMI) or non-ST-elevation MI with an ejection fraction >35% and a CHA2DS2-VASc score ≥4 (men) or ≥5 (women). Interventions: Patients were randomly assigned to receive or not receive an ICM in addition to standard post-MI treatment. Device-detected arrhythmias triggered immediate guideline recommended therapy changes via remote monitoring. Main outcome measures: MACE, defined as a composite of cardiovascular death or acute unscheduled hospitalization for cardiovascular causes. Results: 790 patients (mean age 71 years, 72% male, 51% non-STEMI) of planned 1,400 pts were enrolled and followed for a median of 31.6 months. At 2 years, 39.4% of the device group and 6.7% of the control group had their therapy adapted for an arrhythmia [hazard ratio (HR) = 5.9, P < 0.0001]. Most frequent arrhythmias were atrial fibrillation, pauses and bradycardia. The use of an ICM did not improve outcome in the entire cohort (HR = 0.84, 95%-CI: 0.65-1.10; P = 0.21). In secondary analysis, a statistically significant interaction of the type of infarction suggests a benefit in the pre-specified non-STEMI subgroup. Risk factor analysis indicates that this may be connected to the higher incidence of MACE in patients with non-STEMI. Conclusions: The burden of asymptomatic but actionable arrhythmias is large in post-infarction patients. However, arrhythmia monitoring with an ICM did not improve outcome in the entire cohort. Post-hoc analysis suggests that it may be beneficial in non-STEMI patients or other high-risk subgroups. Clinical Trial Registration: [https://www.clinicaltrials.gov/ct2/show/NCT02341534], NCT02341534.

8.
Front Cardiovasc Med ; 11: 1343424, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38322767

RESUMEN

Introduction: Implantable cardiac monitors (ICMs) provide long-term arrhythmia monitoring, but high rates of false detections increase the review burden. The new "SmartECG" algorithm filters false detections. Using large real-world data sets, we aimed to quantify the reduction in workload and any loss in sensitivity from this new algorithm. Methods: Patients with a BioMonitor IIIm and any device indication were included from three clinical projects. All subcutaneous ECGs (sECGs) transmitted via remote monitoring were classified by the algorithm as "true" or "false." We quantified the relative reduction in workload assuming "false" sECGs were ignored. The remote monitoring workload from five hospitals with established remote monitoring routines was evaluated. Loss in sensitivity was estimated by testing a sample of 2000 sECGs against a clinical board of three physicians. Results: Of our population of 368 patients, 42% had an indication for syncope or pre-syncope and 31% for cryptogenic stroke. Within 418.5 patient-years of follow-up, 143,096 remote monitoring transmissions contained 61,517 sECGs. SmartECG filtered 42.8% of all sECGs as "false," reducing the number per patient-year from 147 to 84. In five hospitals, nine trained reviewers inspected on average 105 sECGs per working hour. This results in an annual working time per patient of 83 min without SmartECG, and 48 min with SmartECG. The loss of sensitivity is estimated as 2.6%. In the majority of cases where true arrhythmias were rejected, SmartECG classified the same type of arrhythmia as "true" before or within 3 days of the falsely rejected sECG. Conclusion: SmartECG increases efficiency in long-term arrhythmia monitoring using ICMs. The reduction of workload by SmartECG is meaningful and the risk of missing a relevant arrhythmia due to incorrect filtering by the algorithm is limited.

10.
J Stroke Cerebrovasc Dis ; 33(1): 107451, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37995501

RESUMEN

OBJECTIVES: Up to 20 % of ischemic strokes are associated with overt atrial fibrillation (AF). Furthermore, silent AF was detected by an implantable cardiac monitor (ICM) in 1 in 3 cryptogenic strokes in the CRYSTAL AF study. An ESC position paper has suggested a HAVOC score ≥ 4 or a Brown ESUS-AF score ≥ 2 as criteria for ICM implantation after cryptogenic stroke, but neither of these criteria has been developed or validated in ICM populations. We assessed the performance of HAVOC and Brown ESUS-AF scores in a cohort of ICM patients implanted after embolic stroke of undetermined source (ESUS). METHODS: All patients implanted with an ICM for ESUS between February 2016 and February 2022 at two French University Hospitals were retrospectively included. Demographic data, cardiovascular risk factors, and clinical and biological data were collected after a review of electronic medical records. HAVOC and Brown ESUS-AF scores were calculated for all patients. FINDINGS: Among the 384 patients included, 106 (27 %) developed AF during a mean follow-up of 33 months. The scores performances for predicting AF during follow-up were: HAVOC= AUC: 68.5 %, C-Index: 0.662, and Brown ESUS-AF=AUC: 72.9 %, C-index 0.712. Compared with the CHA2DS2-VASc score, only the Brown ESUS-AF score showed significant improvement in NRI/IDI. Furthermore, classifying patients according to the suggested HAVOC and Brown ESUS-AF thresholds, only 24 % and 31 % of the cohort, respectively, would have received an ICM, and 58 (55 %) and 47 (44 %) of the AF patients, respectively, would not have been implanted with an ICM. CONCLUSION: HAVOC and Brown ESUS-AF scores showed close and moderate performance in predicting AF on ICM after cryptogenic stroke, with a significant lack of sensitivity. Specific risk scores should be developed and validated in large ICM cohorts.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular Embólico , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/terapia , Accidente Cerebrovascular Embólico/complicaciones , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular Isquémico/complicaciones
11.
Ann Noninvasive Electrocardiol ; 29(1): e13102, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38088202

RESUMEN

INTRODUCTION: Implantable cardiac monitors (ICMs) primarily use R-R intervals in subcutaneous electrocardiograms (ECGs) to detect arrhythmias. Therefore, reliable detection of R-wave amplitude by an ICM is vital. Since ICMs detect subcutaneous ECGs, the impact of the implantation depth should be assessed. METHODS AND RESULTS: This study investigated the influence of ICM depth on R-wave (ICM-R) amplitude on an ECG generated by an ICM (JOT Dx; Abbott). Overall, 58 patients who underwent ICM implantation at Kamagaya General Hospital from May 2022 to April 2023 were retrospectively reviewed. The depth-position was measured using ultrasound imaging after implantation. The depth of the ICM did not show any correlation with ICM-R amplitude (r = -.0141, p = .294). However, the distance between the ICM and the heart surface showed a significant correlation with ICM-R amplitude (r = -.581, p < .001). Body weight (r = -.0283, p = .033) and body mass index (r = -.0342, p = .009) were associated with ICM-R amplitude. S wave in the V1 -lead was also associated with ICM-R amplitude (r = .481, p < .001). After multivariate analysis, the distance between the ICM and heart surface and the S wave in V1 were independent determinants for the ICM-R amplitude. CONCLUSION: The ICM-R amplitude may be higher with the ICM implanted deeper.


Asunto(s)
Electrocardiografía Ambulatoria , Electrocardiografía , Humanos , Electrocardiografía/métodos , Electrocardiografía Ambulatoria/métodos , Estudios Retrospectivos , Arritmias Cardíacas , Prótesis e Implantes
12.
Pediatr Cardiol ; 45(1): 114-120, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38036754

RESUMEN

Cardiac implantable electronic device (CIED) remote transmissions are an integral part of longitudinal follow-up in pediatric and adult congenital heart disease (ACHD) patients. To evaluate baseline CIED remote monitoring (RM) data among pediatric and ACHD centers prior to implementation of a Pediatric and Congenital Electrophysiology  Society (PACES)-sponsored quality improvement (QI) project. This is a cross-sectional study of baseline CIED RM. Centers self-reported baseline data: individual center RM compliance was defined as high if there was > 80% achievement and low if < 50%. A total of 22 pediatric centers in the USA and Australia submitted baseline data. Non-physicians were responsible for management of the RM program in most centers: registered nurse (36%), advanced practice provider (27%), combination (23%), and third party (9%). Fifteen centers (68%) reported that > 80% of their CIED patients are enrolled in RM and only two centers reported < 50% participation. 36% reported high compliance of device transmission within 14 days of implant and 77% of centers reported high compliance of CIED patients enrolled in RM. The number of centers achieving high compliance differed by device type: 36% for pacemakers, 50% for ICDs, and 55% for Implantable Cardiac Monitors (ICM). All centers reported at least 50% adherence to recommended follow-up for PM and ICD, with 23% low compliance rate for ICMs. Based on this cross-sectional survey of pediatric and ACHD centers, compliance with CIED RM is sub-optimal. The PACES-sponsored QI initiative will provide resources and support to participating centers and repeat data will be evaluated after PDSA cycles.


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Marcapaso Artificial , Niño , Humanos , Adulto , Cardiopatías Congénitas/terapia , Estudios Transversales , Mejoramiento de la Calidad , Tecnología de Sensores Remotos
13.
J Cardiovasc Electrophysiol ; 34(12): 2434-2442, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37814483

RESUMEN

INTRODUCTION: Atrial tachyarrhythmia recurrence during the blanking period (early ATA) after pulmonary vein isolation (PVI) is associated with an increased risk of later recurrence, but its relationship with pulmonary vein reconduction (PVR) is poorly understood. The objective of the present study was to evaluate the relationship between early ATA and PVR. Second, to provide data on the optimal blanking period by (a) evaluating how the predictive values of ATA for PVR are affected by blanking period duration, and (b) assessing the temporal development in atrial fibrillation (AF) burden. METHODS: In this RACE-AF substudy, 91 patients with paroxysmal AF undergoing PVI randomized to radiofrequency or cryoballoon ablation were included. All patients received an implantable cardiac monitor and underwent a protocol-mandated repeat procedure after 4-6 months for assessment of PVR. ATA ≥ 30 s. ≤ 90 days after PVI constituted early ATA. RESULTS: PVR was found in 37/54 (69%) patients with early ATA and in 11/37 (30%) patients without (p < .001). The positive predictive value of ATA for PVR was independent of blanking period duration (range 0-90 days). In both patients with and without PVR, AF burden was higher in the first month after PVI, but AF burden from the second month was similar to AF burden after the conventional blanking period. CONCLUSION: Early ATA indicates PVR, and the positive predictive value is independent of the blanking period duration. Altogether, the results of this study support substantially shortening the blanking period after PVI for paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Venas Pulmonares/cirugía , Resultado del Tratamiento , Atrios Cardíacos , Taquicardia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Recurrencia
14.
Artículo en Inglés | MEDLINE | ID: mdl-37851866

RESUMEN

AIMS: Implantation of an implantable cardiac monitor (ICM) is a simple procedure, but adds significant and increasing workload to the arrhythmia service. In 2020, we established a nurse-led ICM implantation service. We aimed to analyze patient satisfaction, adverse events during implant and ICM re-interventions with nurse-led ICM implantation (N-Implant) compared to physician-led ICM implantation (P-Implant). METHOD AND RESULTS: From January 2020 to December 2021 we included all consecutive patients implanted with an ICM in a prospective registry. We collected data on patient characteristics, implant procedure and follow-up. Patients were interviewed by phone four weeks after ICM implantation.Of 321 patients implanted with an ICM (median age 67 years; 33% women), 189 (59%) were N-Implants. More N-Implants were performed in the outpatient clinic compared to P-Implants (95% vs. 8%; p<0.001). Two N-Implant patients experienced vaso-vagal reaction during implantation (1%), whereas no adverse events occurred during P-Implant (p=0.51). 297 patients (93%) completed the questionnaire. Duration of pain was shorter and wound closure after 2 weeks better following N-Implant (p=0.019 and p=0.018). A minor bruise or swelling at the implant site was reported more frequently after N-Implant (p=0.003 and p=0.041). Patient satisfaction was excellent with both N-Implant and P-Implant (99% and 97%; p=0.16). After a median follow-up of 242 days (range 7-725 days), five ICMs (2%) were explanted prematurely, without differences among groups. Reasons for premature explants were local discomfort (n=2), infection, MRI and ICM malfunction. CONCLUSION: Nurse-led ICM implantation has excellent patient satisfaction without compromising safety. N-Implant both expands nursing competencies and reduces physician workload.

15.
Card Electrophysiol Clin ; 15(4): 505-513, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37865523

RESUMEN

Pediatric and congenital heart disease patients may require cardiac implantable electronic device implantation, inclusive of pacemaker, ICD, and implantable cardiac monitor, for a variety of etiologies. While leads, generators, and monitors have decreased in size over the years, they remain less ideal for the smallest patients. The potential for a miniature pacemaker, fetal micropacemaker, improving leadless technology, and rechargeable devices creates hope that the development of pediatric-focused devices will increase. Further, alternative approaches that avoid the need for a transvenous or surgical approach may add more options to the toolbox for the pediatric and congenital electrophysiologist.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Niño , Arritmias Cardíacas , Corazón , Electrocardiografía
17.
Rev. esp. cardiol. (Ed. impr.) ; 76(8): 609-617, Agos. 2023. tab, ilus, graf
Artículo en Español | IBECS | ID: ibc-223494

RESUMEN

Introducción y objetivos: Los pacientes con un episodio sincopal inexplicable único (ESU) y bloqueo completo de rama del haz de His (BcR) con frecuencia se tratan de manera más conservadora que aquellos con episodios recurrentes (ESR). El objetivo fue analizar si existen diferencias entre pacientes con ESU o ESR y BcR en cuanto al riesgo arrítmico, el rendimiento diagnóstico de las pruebas y los resultados clínicos. Métodos: Estudio de cohorte de pacientes consecutivos con seguimiento medio de 3 años. Fueron estudiados mediante un protocolo escalonado basado en un estudio electrofisiológico y seguimiento con un monitor cardiaco implantable (MCI). Resultados: De los 503 pacientes incluidos en el estudio, 238 (47,3%) referían un ESU. El riesgo de síncope arrítmico fue similar en ambos grupos (58,8% ESU frente a 57,0% ESR; p=0,68), también tras ajustar por variables de confusión (HR=1,06; IC95%, 0,81-1,38; p=0,674). No se encontraron diferencias significativas en cuanto a los resultados del estudio electrofisiológico y la rentabilidad diagnóstica del monitor cardiaco implantable. Un total de 141 (59,2%) pacientes con ESU y 154 (58,1%) con ESR requirieron el implante de un dispositivo cardiaco (p=0,797). Tras el tratamiento adecuado, 35 (7%) pacientes presentaron recurrencia del síncope. La tasa de recurrencia y la mortalidad también fueron similares. Conclusiones: Los pacientes con BcR y síncope tienen un alto riesgo de tener una etiología arrítmica, aunque solo hayan presentado un episodio aislado. Los pacientes con ESU y ESR tienen un riesgo arrítmico similar y presentan un pronóstico similar, por lo que no existe una justificación clínica para no tratarlos de la misma manera.(AU)


Introduction and objectives: Patients with a single syncopal episode (SSE) and complete bundle branch block (cBBB) are frequently managed more conservatively than patients with recurrent episodes (RSE). The objective of this study was to analyze if there are differences between patients with single or recurrent unexplained syncope and cBBB in arrhythmic risk, the diagnostic yield of tests, and clinical outcomes. Methods: Cohort study of consecutive patients with unexplained syncope and cBBB with a median follow-up time of 3 years. The patients were evaluated via a stepwise workup protocol based on electrophysiological study (EPS) and long-term follow-up with an implantable cardiac monitor. Results: Of the 503 patients included in the study, 238 (47.3%) had had only 1 syncopal episode. The risk of an arrhythmic syncope was similar in both groups (58.8% in SSE vs 57.0% in RSE; P=.68), also after adjustment for possible confounding variables (HR, 1.06; 95%CI, 0.81-1.38; P=.674). No significant differences between the groups were found in the EPS results and implantable cardiac monitor diagnostic yield. A total of 141 (59.2%) patients with SSE and 154 (58.1%) patients with RSE required cardiac device implantation (P=.797). After appropriate treatment, 35 (7%) patients had recurrence of syncope. The recurrence rate and mortality were also similar in both groups. Conclusions: Patients with cBBB and unexplained syncope are at high risk of an arrhythmic etiology, even after the first syncopal episode. Patients with SSE and RSE have a similar arrhythmic risk and similar outcomes, and therefore there is no clinical justification for not managing them in the same manner.(AU)


Asunto(s)
Humanos , Bloqueo de Rama , Síncope , Marcapaso Artificial , Técnicas Electrofisiológicas Cardíacas , Cardiología , Enfermedades Cardiovasculares , Estudios de Cohortes
18.
JACC Clin Electrophysiol ; 9(10): 2071-2081, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37542487

RESUMEN

BACKGROUND: Persistent shock-resistant atrial fibrillation (AF) is a challenging entity, with modest results from catheter ablation according to conventional survival analysis. OBJECTIVES: The aim of this study was to determine the effect of catheter ablation on atrial tachyarrhythmia (ATA) burden in persistent AF patients undergoing first-time ablation with the use of an implantable cardiac monitor (ICM). METHODS: Patients with drug-resistant ongoing persistent AF and at least 1 previous failed cardioversion were implanted with an ICM 2 months before the procedure. All patients underwent pulmonary vein isolation with or without additional substrate ablation depending on the presence of self-terminating AF on ICM and left atrium size. Median AF burden before and after ablation, off antiarrhythmic medication, was determined from ICM recordings after review by 2 independent investigators. RESULTS: Sixty patients were recruited (mean age 66 ± 9 years, 70% male). Mean left atrial diameter was 48 ± 6 mm and median CHA2DS2VASc score was 2. Ten patients (17%) unexpectedly demonstrated self-terminating AF before ablation. The median burden of ATA before ablation was 100% (95% CI: 19.6%-100%), decreasing to 0% (95% CI: 0%-95.8%) after ablation during the post-blanking follow-up period (median reduction 100%; 95% CI: 4%-100%; P < 0.001). Twenty-seven patients (45%) experienced recurrent ATA during 12-month follow-up. In these patients, median burden before ablation was 100% (95% CI: 26.9%-100%), decreasing to 11.4% (95% CI: 0.35%-99.7%) after ablation (P < 0.001). Quality of life improved significantly from baseline, driven by lack of recurrence. CONCLUSIONS: Patient-tailored catheter ablation results in a significant reduction in ATA burden (off antiarrhythmic medication) in shock-resistant persistent AF patients using ICMs implanted 2-months pre-procedure. These data suggest that conventional arrhythmia-free survival analysis does not capture the true impact of catheter ablation in this challenging cohort.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Calidad de Vida , Resultado del Tratamiento , Antiarrítmicos/uso terapéutico , Ablación por Catéter/métodos
19.
Int J Cardiol ; 389: 131199, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37481001

RESUMEN

BACKGROUND: Remote Monitoring (RM) is recognized for its ability to enhance the clinical management of patients with implantable cardiac monitor (ICM). This study aims to provide a comprehensive description of the arrhythmic episodes transmitted by a daily and automatic RM system from a cohort of ICM patients. METHODS: The study retrospectively analyzed daily transmissions from consecutive patients who had been implanted with a long-sensing vector ICM (BIOMONITOR III/IIIm) at four sites. All transmitted arrhythmic recordings were evaluated to determine whether they were true positive episodes or false positives (FP). RESULTS: A total of 14,136 episodes were transmitted from 119 patients (74.8% male, median age 62 years old) during a median follow-up of 371 days. The rate of arrhythmic episodes was 14.2 per patient-year (interquartile range: 1.8-126), with 97 patients (81.5%) experiencing at least one ICM activation. Fifty-five percent of episodes were identified as FP, and 67 patients (56.3%) had at least one inappropriate activation. The FP rate was 1.4 per patient-year (0-40). The best per-episode predictive positive values were observed for bradycardia and atrial fibrillation (0.595 and 0.553, respectively). Notably, the implementation of an algorithm designed to minimize false detections significantly reduced the prevalence of atrial fibrillation FP episodes (17.6% vs. 43.5%, p = 0.008). CONCLUSION: Daily and automatic RM appears to be a reliable tool for the comprehensive remote management of ICM patients. However, the number of arrhythmic episodes requiring review is high, and further improvements are needed to reduce FP and facilitate accurate interpretation of transmissions.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Humanos , Masculino , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Electrocardiografía Ambulatoria , Electrocardiografía , Algoritmos
20.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37345804

RESUMEN

Atrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences. The presence of AHRE increases the risk of stroke compared with patients without AHRE. Oral anticoagulation would have the potential to reduce the risk of stroke in patients with AHRE but is also associated with a rate of major bleeding of ∼2%/year. The stroke rate in patients with AHRE appears to be lower than the stroke rate in patients with atrial fibrillation. Wearables like smart-watches will increase the absolute number of patients in whom atrial arrhythmias are detected. It remains unclear whether anticoagulation is effective and, equally important, safe in patients with AHRE. Two randomized clinical trials, NOAH-AFNET6 and ARTESiA, are expected to report soon. They will provide much-needed information on the efficacy and safety of oral anticoagulation in patients with AHRE.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Factores de Riesgo , Anticoagulantes/uso terapéutico , Atrios Cardíacos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control