Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Environ Technol ; : 1-16, 2022 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-36318863

RESUMEN

There is increasing interest in membrane-aerated biofilm reactors (MABRs), due to their energy efficiency and ability to intensify wastewater treatment. While MABR membranes play a key role, supporting biofilms and transferring O2, little research has addressed how membrane types impact MABR performance. This research compared two types of membranes used in commercial MABRs: a silicone hollow-fibre membrane and a 'micromembrane cord,' consisting of an inert cord surrounded by fine proprietary polymeric membranes. We used single-membrane MABRs to determine the oxygen mass transfer coefficient, Km, and explore biofilm development. The silicone membrane had a measured Km of 2.6 m/d, and the micromembrane cord had an apparent Km of 1 m/d. Pure MABR bundles (only biofilm) were operated with synthetic wastewater, and hybrid MABRs (suspended biomass and biofilm) with real wastewater, to explore behaviour for a wide range of conditions. The maximum ammonium oxidation fluxes with synthetic wastewater were 7.8 gN/m2d for the silicone membrane and 4.3 gN/m2d for the micromembrane cord. However, at bulk NH4+ concentrations below 5 mgN/L, the ammonium oxidation fluxes were similar. A previously published MABR model effectively captured the behaviour of each membrane. Nitrification fluxes with real wastewater were lower than synthetic wastewater, likely because of the presence of chemical oxygen demand (COD). Although the ammonium oxidation fluxes were higher for the silicone membranes for a given air supply pressure, the fluxes for the micromembrane cord could be increased using higher intramembrane air pressures. Overall, this research helped understand the impact of membrane types on nitrification fluxes.

2.
Membranes (Basel) ; 10(12)2020 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-33322011

RESUMEN

The characterization of membranes is suitable to investigate changes in the membrane properties caused by Layer-by-Layer (LbL) modification. Besides permeability, rejection, and molecular-weight cut-off (MWCO), which give information about the modification of the separation behaviour of the membrane, the zeta potential is capable of describing the surface charge of the membrane and its variation impacted by the properties of the polyelectrolyte multilayers (PEM). In this study, a new method for zeta potential measurement of hollow fibre membranes with several capillaries was developed and further investigations on the LbL modification of such membranes were performed. The results showed that an LbL coating with 8 DL PDADMAC/PSS led to a significant increase in the membrane charge of more than 20 mV. The coating with a different number of polyelectrolyte (PE) layers showed a zig-zag behaviour, comparable to data from flat sheet studies. However, in contrast to most flat sheet membranes, the charge curve assumes a totally negative trajectory at neutral pH. Further experiments on the MWCO of the LbL-modified membrane showed a reduction in the pore diameter from approx. 20 nm to less than 2 nm, reaching the range of nanofiltration membranes. With information on both the zeta potential and the MWCO, it was found that the rejection mechanism in LbL-modified multibore membranes is a complex interplay between the sieving effect due to reduction in the pore diameter and the repulsion effect of the charged membrane.

3.
Angew Chem Int Ed Engl ; 59(42): 18701-18708, 2020 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-32648353

RESUMEN

Dynamic and on-site analysis of serum from human blood is crucial, however, state-of-the-art blood-assay methods can only collect single or discrete data of physiological analytes; thus, the online reports of the dynamic fluctuation of key analytes remains a great challenge. Here, we propose a novel separation-sensing membrane by constructing a heterogeneous-nanostructured architecture, wherein a surface nanoporous layer continuously extracts serum, while the biosensing nanochannels underneath dynamically recognise biotargets, thereby achieving a continuous testing of vital clinical indices as blood is drawn. By precisely controlling the pore structure and nanoshape of biosensing crystals, this membrane achieved accurate and online glucose and lactate monitoring in patients with a variety of medical conditions within 1 min, which is one order of magnitude faster than state-of-the-art techniques. Moreover, various kinds of bio-recognisers can be introduced into this membrane to accurately detect glutamate, transaminase, and cancer biomarkers.


Asunto(s)
Técnicas Biosensibles/métodos , Glucemia/análisis , Ácido Láctico/sangre , Biomarcadores/sangre , Técnicas Electroquímicas , Humanos , Límite de Detección , Membranas Artificiales , Nanoestructuras/química , Polímeros/química , Pirroles/química
4.
Bioresour Technol ; 301: 122672, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31945681

RESUMEN

The objective of this study was to evaluate the performance of an outdoor membrane-coupled high-rate algal pond equipped with industrial-scale membranes for treating urban wastewater. Decoupling biomass retention time (BRT) and hydraulic retention time (HRT) by membrane filtration resulted in improved process efficiencies, with higher biomass productivities and nutrient removal rates when operating at low HRTs. At 6 days of BRT, biomass productivity increased from 30 to 66 and to 95 g·m-3·d-1 when operating at HRTs of 6, 4 and 2.5 days, respectively. The corresponding nitrogen removal rates were 4, 8 and 11 g N·m-3·d-1 and the phosphorous removal rates were 0.5, 1.3 and 1.6 g P·m-3·d-1. The system was operated keeping moderate specific air demands (0.25 m3·m-2·h-1), resulting in reasonable operating and maintenance costs (€0.04 per m3) and energy requirements (0.29 kWh per m3). The produced water was free of pathogens and could be directly used for reusing purposes.


Asunto(s)
Aguas Residuales , Purificación del Agua , Biomasa , Nitrógeno , Estanques , Eliminación de Residuos Líquidos
5.
J Memb Sci ; 565: 425-438, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30393423

RESUMEN

Herein we describe the manufacture and characterisation of biocompatible, porous polystyrene membranes, suitable for cell culture. Though widely used in traditional cell culture, polystyrene has not been used as a hollow fibre membrane due to its hydrophobicity and non-porous structure. Here, we use microcrystalline sodium chloride (4.7 ±â€¯1.3 µm) to control the porosity of polystyrene membranes and oxygen plasma surface treatment to reduce hydrophobicity. Increased porogen concentration correlates to increased surface pore density, macrovoid formation, gas permeability and mean pore size, but a decrease in mechanical strength. For tissue engineering applications, membranes spun from casting solutions containing 40% (w/w) sodium chloride represent a compromise between strength and permeability, having surface pore density of 208.2 ±â€¯29.7 pores/mm2, mean surface pore size of 2.3 ±â€¯0.7 µm, and Young's modulus of 115.0 ±â€¯8.2 MPa. We demonstrate the biocompatibility of the material with an exciting cell line-media combination: transdifferentiation of the AR42J-B13 pancreatic cell line to hepatocyte-like cells. Treatment of AR42J-B13 with dexamethasone/oncostatin-M over 14 days induces transdifferentiation towards a hepatic phenotype. There was a distinct loss of the pancreatic phenotype, shown through loss of expression of the pancreatic marker amylase, and gain of the hepatic phenotype, shown through induction of expression of the hepatic markers transferrin, carbamoylphosphate synthetase and glutamine synthetase. The combination of this membrane fabrication method and demonstration of biocompatibility of the transdifferentiated hepatocytes provides a novel, superior, alternative design for in vitro liver models and bioartificial liver devices.

6.
J Tissue Eng Regen Med ; 12(12): 2319-2330, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30362254

RESUMEN

Several key prerequisites need to be fulfilled for the development of a biohybrid lung, which can offer an actual alternative to lung transplantation. A major aspect is an optimized haemocompatibility of the device's artificial surfaces via endothelial cell seeding. In this study, four different types of polymeric gas exchange hollow fibre membranes (HFMs) were analysed utilizing four different seeding protocols in order to identify the ideal combination for sufficient long-term endothelialization. Human cord blood-derived endothelial cells (HCBECs) were used for the endothelialization of polypropylene HFMs with two different pore sizes and poly-4-methyl-1-pentene HFMs, both with and without heparin/albumin coating. The qualitative and quantitative impact of four different rotational seeding protocols regarding long-term HFM endothelialization and the impact of inflammatory stimulation on the seeded HCBECs were examined by fluorescence microscopy, cell counting, and analysis of relative expression levels of activation, shear stress, and thrombogenic state markers. Optimized endothelial cell seeding and long-term cultivation were only achieved using heparin/albumin-coated poly-4-methyl-1-pentene HFMs, applying 24 hr of rotational speed at 1 rpm followed by 120 hr of static culture. Neither cell-to-HFM contact nor the rotational cultivation procedure showed an impact on the physiological anti-thrombogenic and anti-inflammatory HCBEC activation status. Additionally, the cells maintained their physiological responsiveness towards inflammatory stimulation. Rotational seeding strategies and a seamless heparin/albumin coating of the HFMs are crucial requirements for a sufficient and long-lasting endothelialization and thus a key element in the future development and in vivo application of the biohybrid lung.


Asunto(s)
Órganos Artificiales , Materiales Biocompatibles Revestidos/farmacología , Endotelio Vascular/crecimiento & desarrollo , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Pulmón , Membranas Artificiales , Técnicas de Cultivo de Célula , Materiales Biocompatibles Revestidos/química , Endotelio Vascular/citología , Células Endoteliales de la Vena Umbilical Humana/citología , Humanos
7.
Bioresour Technol ; 158: 365-73, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24650614

RESUMEN

The results of a global sensitivity analysis of a filtration model for submerged anaerobic MBRs (AnMBRs) are assessed in this paper. This study aimed to (1) identify the less- (or non-) influential factors of the model in order to facilitate model calibration and (2) validate the modelling approach (i.e. to determine the need for each of the proposed factors to be included in the model). The sensitivity analysis was conducted using a revised version of the Morris screening method. The dynamic simulations were conducted using long-term data obtained from an AnMBR plant fitted with industrial-scale hollow-fibre membranes. Of the 14 factors in the model, six were identified as influential, i.e. those calibrated using off-line protocols. A dynamic calibration (based on optimisation algorithms) of these influential factors was conducted. The resulting estimated model factors accurately predicted membrane performance.


Asunto(s)
Reactores Biológicos , Filtración/métodos , Membranas Artificiales , Modelos Teóricos , Anaerobiosis , Calibración
SELECCIÓN DE REFERENCIAS