Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
HSS J ; 20(2): 261-267, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-39282003

RESUMEN

Background: While the comprehensive care for joint replacement (CJR) bundled payment program for total joint replacement (TJR) emphasizes value, concerns persist regarding unintended consequences, primarily hospital selection of healthier, younger patients. Purpose: We sought to assess changes in patient characteristics and outcomes after CJR implementation in New York State. Methods: This retrospective cohort study included primary total hip and total knee arthroplasties from the New York Statewide Planning and Research Cooperative System (SPARCS) database. Procedures performed before (July 2014 to March 2016; n = 58,610) and after (April 2016 to December 2017; n = 78,728) CJR implementation were compared. Primary outcomes were patient characteristics: Deyo-Comorbidity Index and age. Secondary outcomes were increased hospitalization cost, discharge to institutional post-acute care, and prolonged length of stay. A difference-in-differences analysis estimated changes after CJR implementation, comparing CJR to non-CJR hospitals. Results: We found that CJR implementation (in 49 of 144 New York State hospitals) coincided with slightly older and more comorbid TJR recipients. The CJR program coincided with significantly reduced hospitalization cost and discharge to institutional post-acute care but not length of stay. Some CJR effects appear to have affected non-Medicare patients, as well. Conclusion: This retrospective analysis suggests that in New York State, the CJR bundled payment program did not result in hospitals selecting younger and healthier TJR recipients and coincided with decreased costs and fewer discharges to institutional postacute care.

2.
Nutrients ; 15(23)2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-38068726

RESUMEN

Diet quantity and quality in older adults is critical for the proper functioning of the musculoskeletal system. In view of hip surgery, old patients should consume 1.2-1.5 g of proteins and 27-30 kcal per kilo of body weight daily, and adhere to healthy eating habits. In this analytical study, we studied diet quantity and quality in relation to the clinical chemistry and functional status of 57 older adults undergoing elective hip replacement. Nine in ten patients did not meet suggested protein and energy intakes and only one in ten patients exhibited high adherence to the Mediterranean diet. Legume consumption adjusted for sex, age, body mass index, and health status successfully forecasted haemoglobin levels (p < 0.05), and patients regularly consuming olive oil reported minor hip disability compared to those using it less frequently (p < 0.05). Patients who reported daily ingestion of <1 serving of meat versus those consuming >1.5 servings had greater cumulative comorbidity (p < 0.05), with meat consumption independently predicting walking ability, mobility, and balance in the fully adjusted model (p < 0.01). In conclusion, our patients seem to eat poorly. There is room for improvement in pre-operative pathways to make older adults eat better, but there is a need to plan an interventional study to fully understand the cause-effect of a dietary pattern or specific food in enhancing recovery after surgery.


Asunto(s)
Dieta Mediterránea , Osteoartritis de la Cadera , Humanos , Anciano , Osteoartritis de la Cadera/cirugía , Dieta , Ingestión de Energía , Peso Corporal , Verduras , Conducta Alimentaria
3.
J Pers Med ; 13(9)2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37763149

RESUMEN

Severe symptoms such as hypoxemia, hypotension, and unexpected loss of consciousness may develop during surgical interventions that use polymethyl methacrylate (PMMA), or as it is commonly known, bone cement. Physicians recognize this amalgam of clinical manifestations more and more as a distinct entity that bears the name of bone cement implantation syndrome (BCIS). Trauma cases, especially hip fractures, are seen to have a higher incidence of developing this complication compared to orthopedic elective ones. This research aims to present a detailed description of six severe BCIS cases in order to raise awareness and to emphasize its importance. Five of them had fatal outcomes, which demonstrate the necessity of future research on this topic, as little is known about it presently. In the Discussion section, a narrative overview from the scientific literature is performed on potential risk factors, prevention measures, and management strategies. The experience gathered through this case series may aid medical staff in the development of diagnostic and therapeutic protocols, thus improving safety when cemented surgical techniques are used on a high-risk group of patients.

4.
J Arthroplasty ; 38(10): 1959-1966, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37315632

RESUMEN

BACKGROUND: The rates of blood transfusion following primary and revision total hip arthroplasty (THA) remain as high as 9% and 18%, respectively, contributing to patient morbidity and healthcare costs. Existing predictive tools are limited to specific populations, thereby diminishing their clinical applicability. This study aimed to externally validate our previous institutionally developed machine learning (ML) algorithms to predict the risk of postoperative blood transfusion following primary and revision THA using national inpatient data. METHODS: Five ML algorithms were trained and validated using data from 101,266 primary THA and 8,594 revision THA patients from a large national database to predict postoperative transfusion risk after primary and revision THA. Models were assessed and compared based on discrimination, calibration, and decision curve analysis. RESULTS: The most important predictors of transfusion following primary and revision THA were preoperative hematocrit (<39.4%) and operation time (>157 minutes), respectively. All ML models demonstrated excellent discrimination (area under the curve (AUC) >0.8) in primary and revision THA patients, with artificial neural network (AUC = 0.84, slope = 1.11, intercept = -0.04, Brier score = 0.04), and elastic-net-penalized logistic regression (AUC = 0.85, slope = 1.08, intercept = -0.01, and Brier score = 0.12) performing best, respectively. On decision curve analysis, all 5 models demonstrated a higher net benefit than the conventional strategy of intervening for all or no patients in both patient cohorts. CONCLUSIONS: This study successfully validated our previous institutionally developed ML algorithms for the prediction of blood transfusion following primary and revision THA. Our findings highlight the potential generalizability of predictive ML tools developed using nationally representative data in THA patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Aprendizaje Automático , Redes Neurales de la Computación , Algoritmos , Transfusión Sanguínea , Estudios Retrospectivos
5.
SICOT J ; 9: 17, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37278510

RESUMEN

BACKGROUND: Excellent midterm results for total hip arthroplasties (THA) with cementless, tapered porous Taperloc® femoral stems have been reported. Reports regarding such cemented stems, however, are lacking. OBJECTIVES: To evaluate the long-term outcomes of both cemented and cementless THAs with the Taperloc femoral component. METHODS: The medical records of 71 patients (76 hips), operated on between January 1991 and December 2003, who had a minimum follow-up of 10 years were available for analysis. Functional analysis was performed with the Harris hip score (HHS) questionnaire and the numerical analogue scale (NAS). Radiographic analysis was performed for subsidence, radiolucent lines and osteolysis. RESULTS: The cohort was comprised of 47 female and 24 male patients, with a mean age of 59.7 ± 12.4 years. The mean follow-up was 17.8 ± 4.4 years. 52.6% of THAs analyzed were cementless and 47.4% were cemented. Post-operative radiographs were available for 57 surgeries. Subsidence, hypertrophic ossification, radiolucent lines and osteolysis were noted in 4 (7%), 2 (2.6%), 14 (18.4%) and 11 (14.5%) hips respectively. The average HHS score at a mean follow-up of 20.1 ± 3.9 years was 62.1 (±27.7) and the NAS score was 4.6 (±3.6). During the study period, five revision surgeries were performed due to stem-related problems, one of which was for aseptic loosening. CONCLUSIONS: Our long-term experience with the Taperloc stem, both cemented and cementless, demonstrates good outcomes, with low rates of failure. This makes this prosthesis an attractive option for THAs. LEVEL OF EVIDENCE: IV.

6.
Bone Jt Open ; 3(8): 628-640, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35965477

RESUMEN

AIMS: In the UK, the NHS generates an estimated 25 megatonnes of carbon dioxide equivalents (4% to 5% of the nation's total carbon emissions) and produces over 500,000 tonnes of waste annually. There is limited evidence demonstrating the principles of sustainability and its benefits within orthopaedic surgery. The primary aim of this study was to analyze the environmental impact of orthopaedic surgery and the environmentally sustainable initiatives undertaken to address this. The secondary aim of this study was to describe the barriers to making sustainable changes within orthopaedic surgery. METHODS: A literature search was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines through EMBASE, Medline, and PubMed libraries using two domains of terms: "orthopaedic surgery" and "environmental sustainability". RESULTS: A total of 13 studies were included in the final analysis. All papers studied the environmental impact of orthopaedic surgery in one of three areas: waste management, resource consumption, and carbon emissions. Waste segregation was a prevalent issue and described by nine studies, with up to 74.4% of hazardous waste being generated. Of this, six studies reported recycling waste and up to 43.9% of waste per procedure was recyclable. Large joint arthroplasties generated the highest amount of recyclable waste per procedure. Three studies investigated carbon emissions from intraoperative consumables, sterilization methods, and through the use of telemedicine. One study investigated water wastage and demonstrated that simple changes to practice can reduce water consumption by up to 63%. The two most common barriers to implementing environmentally sustainable changes identified across the studies was a lack of appropriate infrastructure and lack of education and training. CONCLUSION: Environmental sustainability in orthopaedic surgery is a growing area with a wide potential for meaningful change. Further research to cumulatively study the carbon footprint of orthopaedic surgery and the wider impact of environmentally sustainable changes is necessary.Cite this article: Bone Jt Open 2022;3(8):628-640.

7.
Bone Joint J ; 104-B(7): 833-843, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35775177

RESUMEN

AIMS: This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). METHODS: Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years' follow-up. RESULTS: Patients in Group C were associated with increased mean liner wear rates compared to patients in Group A (0.133 mm/yr (SD 0.21) vs 0.031 mm/yr (SD 0.07), respectively; p < 0.001) and Group B (0.133 mm/yr (SD 0.21) vs 0.022 mm/yr (SD 0.05), respectively; p < 0.001) at ten years' follow-up. Patients in Group C were also associated with increased risk of osteolysis and aseptic loosening requiring revision surgery, compared with patients in Group A (7/133 vs 0/133, respectively; p = 0.007) and Group B (7/133 vs 0/135, respectively; p = 0.007). There was a non-statistically significant trend towards increased mean liner wear rates in Group A compared with Group B (0.031 mm/yr (SD 0.07) vs 0.022 mm/yr (SD 0.05), respectively; p = 0.128). All three groups were statistically comparable preoperatively and at ten years' follow-up when measuring normalized Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.410), 36-Item Short Form Health Survey (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p = 0.451). CONCLUSION: The use of UHMWPE was associated with progressively increased annual liner wear rates after THA compared to XLPE. At ten years' follow-up, the group receiving UHMWPE demonstrated an increased incidence of osteolysis and aseptic loosening requiring revision surgery compared to XLPE. Femoral heads composed of OxZr were associated with trend towards reduced wear rates compared to CoCr, but this did not reach statistical significance and did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two femoral head components. Cite this article: Bone Joint J 2022;104-B(7):833-843.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteólisis , Artroplastia de Reemplazo de Cadera/efectos adversos , Aleaciones de Cromo , Cobalto , Cabeza Femoral/cirugía , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Osteólisis/cirugía , Polietileno , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Circonio
8.
Bone Joint J ; 104-B(5): 598-603, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35491581

RESUMEN

AIMS: The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes. METHODS: We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m2 (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2). RESULTS: Three liners (1.2%) were malseated, including two MDMs (1.4%) and one G7 (0.9%). No clinical consequence was identified from malseating. The five-year survival free of dislocation was 97.1%, including two DM and one intraprosthetic dislocation. The five-year survival free of revision was 95.4%, with seven revisions. The mean Harris Hip Scores increased from 46 (24 to 69) preoperatively to 81 (40 to 100) at two years postoperatively (p < 0.001). CONCLUSION: The incidence of DM liner malseating after primary THA was low, with no known clinical consequences at mid-term follow-up. Malseating is not exclusive of design, and these findings emphasize the importance of careful evaluation of the liner after impaction to avoid this complication. Cite this article: Bone Joint J 2022;104-B(5):598-603.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos
9.
Bone Joint J ; 104-B(5): 589-597, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35491583

RESUMEN

AIMS: Total hip arthroplasty (THA) is one of the most successful surgical procedures. The objectives of this study were to define whether there is a correlation between socioeconomic status (SES) and surgical complications after elective primary unilateral THA, and investigate whether access to elective THA differs within SES groups. METHODS: We conducted a retrospective, population-based cohort study involving 202 hospitals in Ontario, Canada, over a 17-year period. Patients were divided into income quintiles based on postal codes as a proxy for personal economic status. Multivariable logistic regression models were then used to primarily assess the relationship between SES and surgical complications within one year of index THA. RESULTS: Of 111,359 patients who underwent elective primary THA, those in the lower SES groups had statistically significantly more comorbidities and statistically significantly more postoperative complications. While there was no increase in readmission rates within 90 days, there was a statistically significant difference in the primary and secondary outcomes including all revisions due (with a subset of deep wound infection and dislocation). Results showed that those in the higher SES groups had proportionally more cases performed than those in lower groups. Compared to the highest SES quintile, the lower groups had 61% of the number of hip arthroplasties performed. CONCLUSION: Patients in lower socioeconomic groups have more comorbidities, fewer absolute number of cases performed, have their procedures performed in lower-volume centres, and ultimately have higher rates of complications. This lack of access and higher rates of complications is a "double hit" to those in lower SES groups, and indicates that we should be concentrating efforts to improve access to surgeons and hospitals where arthroplasty is routinely performed in high numbers. Even in a universal healthcare system where there are no penalties for complications such as readmission, there seems to be an inequality in the access to THA. Cite this article: Bone Joint J 2022;104-B(5):589-597.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Cohortes , Humanos , Ontario/epidemiología , Estudios Retrospectivos , Factores Socioeconómicos , Atención de Salud Universal
10.
Bone Jt Open ; 3(3): 229-235, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35285702

RESUMEN

AIMS: With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases. METHODS: A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant - Modular Endo-prosthetic Tumour System (METS). RESULTS: At mean follow-up of 5.9 years, there were no periprosthetic fractures. Clearance of infection was achieved in 63.6% of cases. One hip was re-revised to pseudo arthroplasty for deep infection. Instability was noted in eight of the hips (32%), of which seven needed further surgery. Out of these eight hips with instability, five had preoperative infection. Deep infection was noted in five of the hips (20%), of which four were primarily revised for infection. One patient had aseptic loosening of the femoral component and awaits revision surgery. The Kaplan-Meier survivorship free of revision of any component for any reason was 72% (95% confidence interval (CI) 51.3% to 92.7%), and for revisions of only femoral component for any reason was 96% (95% CI 86.3% to 105.7%) at five years. CONCLUSION: Dislocation and infection remain the major cause for failure, particularly in patients with pre-existing infection. The use of dual mobility cups, silver-coated implants, and less aggressive postoperative rehabilitation regimens would possibly aid in the reduction of complications. PFA performed in patients with periprosthetic fracture seem to fair better. This study supports the judicious use of PFA in non-oncological revision hip arthroplasties, and that they be performed by experienced revision arthroplasty surgeons. Cite this article: Bone Jt Open 2022;3(3):229-235.

11.
Bone Joint J ; 104-B(3): 359-367, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35227088

RESUMEN

AIMS: A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS: Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS: There were 158,677 individuals (42.4%) with an implant containing CoCr. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association between patients with CoCr implants and higher rates of any of the outcomes. CONCLUSION: CoCr-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer, or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of CoCr-containing implants is not associated with significant adverse systemic effects. Cite this article: Bone Joint J 2022;104-B(3):359-367.


Asunto(s)
Aleaciones de Cromo/efectos adversos , Cardiopatías/etiología , Cardiopatías/mortalidad , Prótesis de Cadera/efectos adversos , Neoplasias/etiología , Neoplasias/mortalidad , Enfermedades Neurodegenerativas/etiología , Enfermedades Neurodegenerativas/mortalidad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Anciano , Anciano de 80 o más Años , Causas de Muerte , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Reino Unido
12.
Bone Joint J ; 104-B(3): 368-375, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35227093

RESUMEN

AIMS: The aim of this study was to determine the outcome of all primary total hip arthroplasties (THAs) and their subsequent revision procedures in patients aged under 50 years performed at our institution. METHODS: All 1,049 primary THAs which were undertaken in 860 patients aged under 50 years between 1988 and 2018 in our tertiary care institution were included. We used cemented implants in both primary and revision surgery. Impaction bone grafting was used in patients with acetabular or femoral bone defects. Kaplan-Meier analyses were used to determine the survival of primary and revision THA with the endpoint of revision for any reason, and of revision for aseptic loosening. RESULTS: The mean age of the patients at the time of the initial THA was 38.6 years (SD 9.3). The mean follow-up of the THA was 8.7 years (2.0 to 31.5). The rate of survival for all primary THAs, acetabular components only, and femoral components only at 20 years' follow-up with the endpoint of revision for any reason, was 66.7% (95% confidence interval (CI) 60.5 to 72.2), 69.1% (95% CI 63.0 to 74.4), and 83.2% (95% CI 78.1 to 87.3), respectively. A total of 138 revisions were performed. The mean age at the time of revision was 48.2 years (23 to 72). Survival of all subsequent revision procedures, revised acetabular, and revised femoral components at 15 years' follow-up with the endpoint of revision for any reason was 70.3% (95% CI 56.1 to 80.7), 69.7% (95% CI 54.3 to 80.7), and 76.2% (95% CI 57.8 to 87.4), respectively. A Girdlestone excision arthroplasty was required in six of 860 patients (0.7%). CONCLUSION: The long-term outcome of cemented primary and subsequent revision THA is promising in these young patients. We showed that our philosophy of using impaction bone grafting in patients with acetabular and femoral defects is a very suitable option when treating young patients. Surgeons should realize that knowledge of the outcome of subsequent revision surgery, which is inevitable in young patients, must be communicated to this group of patients prior to their initial THA. Cite this article: Bone Joint J 2022;104-B(3):368-375.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Complicaciones Posoperatorias/cirugía , Reoperación/estadística & datos numéricos , Adulto , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
13.
Bone Joint J ; 104-B(3): 341-351, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35227094

RESUMEN

AIMS: Total hip arthroplasties (THAs) are performed by surgeons at various stages in training with varying levels of supervision, but we do not know if this is safe practice with comparable outcomes to consultant-performed THA. Our aim was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THA. METHODS: We performed an observational study using National Joint Registry (NJR) data. We included adult patients who underwent primary THA for osteoarthritis, recorded in the NJR between 2003 and 2016. Exposures were operating surgeon grade (consultant or trainee) and whether or not trainees were directly supervised by a scrubbed consultant. Outcomes were all-cause revision and the indication for revision up to ten years. We used methods of survival analysis, adjusted for patient, operation, and healthcare setting factors. RESULTS: We included 603,474 THAs, of which 58,137 (9.6%) procedures were performed by a trainee. There was no association between surgeon grade and all-cause revision up to ten years (crude hazard ratio (HR) 1.00 (95% confidence interval (CI) 0.94 to 1.07); p = 0.966), a finding which persisted with adjusted analysis. Fully adjusted analysis demonstrated an association between trainees operating without scrubbed consultant supervision and an increased risk of all-cause revision (HR 1.10 (95% CI 1.00 to 1.21); p = 0.045). There was an association between trainee-performed THA and revision for instability (HR 1.14 (95% CI 1.01 to 1.30); p = 0.039). However, this was not observed in adjusted models, or when trainees were supervised by a scrubbed consultant. CONCLUSION: Within the current training system in England and Wales, appropriately supervised trainees achieve comparable THA survival to consultants. Trainees who are supervised by a scrubbed consultant achieve superior outcomes compared to trainees who are not supervised by a scrubbed consultant, particularly in terms of revision for instability. Cite this article: Bone Joint J 2022;104-B(3):341-351.


Asunto(s)
Artroplastia de Reemplazo de Cadera/normas , Competencia Clínica , Reoperación/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo
14.
Bone Joint J ; : 1-9, 2022 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-35018786

RESUMEN

AIMS: A recent report from France suggested an association between the use of cobalt-chrome femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. Cobalt-chrome is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint replacements and other orthopaedic procedures in which cobalt-chrome is used annually. We examined whether cobalt-chrome-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS: Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years follow-up. We excluded any patients with bilateral THAs, knee replacements, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing cobalt-chrome or not containing cobalt-chrome. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS: There were 158,677 individuals (42.4%) with an implant containing cobalt-chrome. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association that patients with cobalt-chrome implants had higher rates of any of the outcomes. CONCLUSION: Cobalt-chrome-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of cobalt-chrome containing implants is not associated with significant adverse systemic effects.

15.
Bone Joint J ; 103-B(12): 1774-1782, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34847718

RESUMEN

AIMS: The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening. METHODS: A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries. RESULTS: The distribution of liner geometries were neutral (39.4%; 79,822), 10° (34.5%; 69,894), 15° (21.6%; 43,722), offset reorientating (2.8%; 5705), offset neutral (0.9%; 1,767), and 20° (0.8%; 1,601). There were 690 (0.34%) revisions for instability. Compared to neutral liners, the adjusted subhazard ratios of revision for instability were: 10°, 0.64 (p < 0.001); 15°, 0.48 (p < 0.001); and offset reorientating, 1.6 (p = 0.010). No association was found with other geometries. 10° and 15° liners had a time-dependent lower risk of revision for instability within the first 1.2 years. In posterior approaches, 10° and 15° liners had a lower risk of revision for instability, with no significant difference between them. The protective effect of lipped over neutral liners was not observed in laterally approached THAs. There were 604 (0.3%) revisions for loosening, but no association between liner geometry and revision for loosening was found. CONCLUSION: This registry-based study confirms a lower risk of revision for instability in posterior approach THAs with 10° or 15° lipped liners compared to neutral liners, but no significant difference between these lip sizes. A higher revision risk is seen with offset reorientating liners. The benefit of lipped geometries against revision for instability was not seen in laterally approached THAs. Liner geometry does not seem to influence the risk of revision for loosening. Cite this article: Bone Joint J 2021;103-B(12):1774-1782.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Diseño de Prótesis , Falla de Prótesis/etiología , Reoperación/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polietileno , Modelos de Riesgos Proporcionales , Sistema de Registros , Riesgo , Adulto Joven
16.
Bone Jt Open ; 2(10): 858-864, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34658249

RESUMEN

AIMS: Prior studies have identified that malseating of a modular dual mobility liner can occur, with previous reported incidences between 5.8% and 16.4%. The aim of this study was to determine the incidence of malseating in dual mobility implants at our institution, assess for risk factors for liner malseating, and investigate whether liner malseating has any impact on clinical outcomes after surgery. METHODS: We retrospectively reviewed the radiographs of 239 primary and revision total hip arthroplasties with a modular dual mobility liner. Two independent reviewers assessed radiographs for each patient twice for evidence of malseating, with a third observer acting as a tiebreaker. Univariate analysis was conducted to determine risk factors for malseating with Youden's index used to identify cut-off points. Cohen's kappa test was used to measure interobserver and intraobserver reliability. RESULTS: In all, 12 liners (5.0%), including eight Stryker (6.8%) and four Zimmer Biomet (3.3%), had radiological evidence of malseating. Interobserver reliability was found to be 0.453 (95% confidence interval (CI) 0.26 to 0.64), suggesting weak inter-rater agreement, with strong agreement being greater than 0.8. We found component size of 50 mm or less to be associated with liner malseating on univariate analysis (p = 0.031). Patients with malseated liners appeared to have no associated clinical consequences, and none required revision surgery at a mean of 14 months (1.4 to 99.2) postoperatively. CONCLUSION: The incidence of liner malseating was 5.0%, which is similar to other reports. Component size of 50 mm or smaller was identified as a risk factor for malseating. Surgeons should be aware that malseating can occur and implant design changes or changes in instrumentation should be considered to lower the risk of malseating. Although further follow-up is needed, it remains to be seen if malseating is associated with any clinical consequences. Cite this article: Bone Jt Open 2021;2(10):858-864.

17.
Bone Joint Res ; 10(10): 639-649, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34605661

RESUMEN

AIMS: Acetabular edge-loading was a cause of increased wear rates in metal-on-metal hip arthroplasties, ultimately contributing to their failure. Although such wear patterns have been regularly reported in retrieval analyses, this study aimed to determine their in vivo location and investigate their relationship with acetabular component positioning. METHODS: 3D CT imaging was combined with a recently validated method of mapping bearing surface wear in retrieved hip implants. The asymmetrical stabilizing fins of Birmingham hip replacements (BHRs) allowed the co-registration of their acetabular wear maps and their computational models, segmented from CT scans. The in vivo location of edge-wear was measured within a standardized coordinate system, defined using the anterior pelvic plane. RESULTS: Edge-wear was found predominantly along the superior acetabular edge in all cases, while its median location was 8° (interquartile range (IQR) -59° to 25°) within the anterosuperior quadrant. The deepest point of these scars had a median location of 16° (IQR -58° to 26°), which was statistically comparable to their centres (p = 0.496). Edge-wear was in closer proximity to the superior apex of the cups with greater angles of acetabular inclination, while a greater degree of anteversion influenced a more anteriorly centred scar. CONCLUSION: The anterosuperior location of edge-wear was comparable to the degradation patterns observed in acetabular cartilage, supporting previous findings that hip joint forces are directed anteriorly during a greater portion of walking gait. The further application of this novel method could improve the current definition of optimal and safe acetabular component positioning. Cite this article: Bone Joint Res 2021;10(10):639-649.

18.
Bone Joint J ; 103-B(9): 1479-1487, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34465151

RESUMEN

AIMS: The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). METHODS: We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression. RESULTS: A total of 213,146 THAs were included in the analysis. Overall, 2,997 revisions were recorded, 1,569 in THAs with a flat liner and 1,428 in THAs using an asymmetric liner. Flat liner THAs had a higher risk of revision for any reason than asymmetric liner THAs when implanted through a Hardinge/anterolateral approach (hazard ratio (HR) 1.169, 95% confidence interval (CI) 1.022 to 1.337) and through a posterior approach (HR 1.122, 95% CI 1.108 to 1.346). There was no increased risk of revision for aseptic loosening when asymmetric liners were used for any surgical approach. A separate analysis of the three most frequently used crosslinked polyethylene liners was in agreement with this finding. When analyzing THAs with flat liners only, THAs implanted through a Hardinge/anterolateral approach were associated with a reduced risk of revision for instability compared to posterior approach THAs (HR 0.561 (95% CI 0.446 to 0.706)). When analyzing THAs with an asymmetric liner, there was no significant difference in the risk of revision for instability between the two approaches (HR 0.838 (95% CI 0.633 to 1.110)). CONCLUSION: For THAs implanted through the posterior approach, the use of asymmetric liners reduces the risk of revision for instability and revision for any reason. In THAs implanted through a Hardinge/anterolateral approach, the use of an asymmetric liner was associated with a reduced risk of revision. The effect on revision for instability was less pronounced than in the posterior approach. Cite this article: Bone Joint J 2021;103-B(9):1479-1487.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Polietileno/química , Diseño de Prótesis , Reoperación/estadística & datos numéricos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Sistema de Registros
19.
Bone Jt Open ; 2(8): 679-684, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34409843

RESUMEN

AIMS: In countries with social healthcare systems, such as Canada, patients may experience long wait times and a decline in their health status prior to their operation. The aim of this study is to explore the association between long preoperative wait times (WT) and acute hospital length of stay (LoS) for primary arthroplasty of the knee and hip. METHODS: The study population was obtained from the provincial Patient Access Registry Nova Scotia (PARNS) and the Canadian national hospital Discharge Access Database (DAD). We included primary total knee and hip arthroplasties (TKA, THA) between 2011 and 2017. Patients waiting longer than the recommended 180 days Canadian national standard were compared to patients waiting equal or less than the standard WT. The primary outcome measure was acute LoS postoperatively. Secondarily, patient demographics, comorbidities, and perioperative parameters were correlated with LoS with multivariate regression. RESULTS: A total of 11,833 TKAs and 6,627 THAs were included in the study. Mean WT for TKA was 348 days (1 to 3,605) with mean LoS of 3.6 days (1 to 98). Mean WT for THA was 267 days (1 to 2,015) with mean LoS of 4.0 days (1 to 143). There was a significant increase in mean LoS for TKA waiting longer than 180 days (2.5% (SE 1.1); p = 0.028). There was no significant association for THA. Age, sex, surgical year, admittance from home, rural residence, household income, hospital facility, the need for blood transfusion, and comorbidities were all found to influence LoS. CONCLUSION: Surgical WT longer than 180 days resulted in increased acute LoS for primary TKA. Meeting a shorter WT target may be cost-saving in a social healthcare system by having shorter LoS. Cite this article: Bone Jt Open 2021;2(8):679-684.

20.
Healthcare (Basel) ; 9(5)2021 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-33946724

RESUMEN

BACKGROUND: The purpose of this study was to provide a comprehensive assessment of the impact of the COVID-19 pandemic on the epidemiology of primary and revision arthroplasties of the hip and knee joint. METHODS: This study compared the data on knee and hip arthroplasty procedures from 2 hospitals (primary and revision) conducted in two periods: the period of the COVID-19 pandemic in Poland (from 4 March 2020 to 15 October 2020) and the corresponding period prior to the pandemic (from 4 March 2019 to 15 October 2019). We compared the epidemiological data, demographic data, and hospital stay duration data from these two periods. RESULTS: Our analysis demonstrated that the total number of hip arthroplasties conducted in 2020 decreased by 26% in comparison with 2019. In the case of knee arthroplasties, the total number of procedures in the evaluated period in 2020 decreased by 44%. Our study also showed that the mean time of hospital stay for orthopedic patients following hip or knee arthroplasty was 22.87% shorter. The female-to-male patient ratio decreased between the analyzed periods, and this was 22.96% lower during the pandemic. CONCLUSION: The COVID-19 pandemic in these two hospitals in Poland led to reduced numbers of hip and knee replacement procedures, shorter hospital stays, and a decreased female-to-male patient ratio. The mean age of patients undergoing hip or knee arthroplasty remained unchanged during the national lockdown with respect to the pre-pandemic figure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA