Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Comput Med Imaging Graph ; 113: 102333, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38281420

RESUMEN

Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) can be used as a non-invasive method for the assessment of myocardial perfusion. The acquired images can be utilised to analyse the spatial extent and severity of myocardial ischaemia (regions with impaired microvascular blood flow). In the present paper, we propose a novel generalisable spatio-temporal hierarchical Bayesian model (GST-HBM) to automate the detection of ischaemic lesions and improve the in silico prediction accuracy by systematically integrating spatio-temporal context information. We present a computational inference procedure with an adequate trade-off between accuracy and computational efficiency, whereby model parameters are sampled from the posterior distribution with Gibbs sampling, while lower-level hyperparameters are selected using model selection strategies based on the Watanabe Akaike information criterion (WAIC). We have assessed our method on both synthetic (in silico) data with known gold-standard and 12 sets of clinical first-pass myocardial perfusion DCE-MRI datasets. We have also carried out a comparative performance evaluation with four established alternative methods: Gaussian mixture model (GMM), opening and closing operations based on Gaussian mixture model (GMMC&Omax), Markov random field constrained Gaussian mixture model (GMM-MRF) and model-based hierarchical Bayesian model (M-HBM). Our results show that the proposed GST-HBM method achieves much higher in silico prediction accuracy than the established alternative methods. Furthermore, this method appears to provide a more robust delineation of ischaemic lesions in datasets affected by spatially variant noise.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen por Resonancia Magnética , Humanos , Teorema de Bayes , Imagen por Resonancia Magnética/métodos
2.
Magn Reson Med ; 88(4): 1575-1591, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35713206

RESUMEN

PURPOSE: To propose respiratory motion-informed locally low-rank reconstruction (MI-LLR) for robust free-breathing single-bolus quantitative 3D myocardial perfusion CMR imaging. Simulation and in-vivo results are compared to locally low-rank (LLR) and compressed sensing reconstructions (CS) for reference. METHODS: Data were acquired using a 3D Cartesian pseudo-spiral in-out k-t undersampling scheme (R = 10) and reconstructed using MI-LLR, which encompasses two stages. In the first stage, approximate displacement fields are derived from an initial LLR reconstruction to feed a motion-compensated reference system to a second reconstruction stage, which reduces the rank of the inverse problem. For comparison, data were also reconstructed with LLR and frame-by-frame CS using wavelets as sparsifying transform ( ℓ1$$ {\ell}_1 $$ -wavelet). Reconstruction accuracy relative to ground truth was assessed using synthetic data for realistic ranges of breathing motion, heart rates, and SNRs. In-vivo experiments were conducted in healthy subjects at rest and during adenosine stress. Myocardial blood flow (MBF) maps were derived using a Fermi model. RESULTS: Improved uniformity of MBF maps with reduced local variations was achieved with MI-LLR. For rest and stress, intra-volunteer variation of absolute and relative MBF was lower in MI-LLR (±0.17 mL/g/min [26%] and ±1.07 mL/g/min [33%]) versus LLR (±0.19 mL/g/min [28%] and ±1.22 mL/g/min [36%]) and versus ℓ1$$ {\ell}_1 $$ -wavelet (±1.17 mL/g/min [113%] and ±6.87 mL/g/min [115%]). At rest, intra-subject MBF variation was reduced significantly with MI-LLR. CONCLUSION: The combination of pseudo-spiral Cartesian undersampling and dual-stage MI-LLR reconstruction improves free-breathing quantitative 3D myocardial perfusion CMR imaging under rest and stress condition.


Asunto(s)
Imagen de Perfusión Miocárdica , Adenosina , Circulación Coronaria , Humanos , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Imagen de Perfusión Miocárdica/métodos , Respiración
3.
Magn Reson Med ; 88(3): 1140-1155, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35608225

RESUMEN

PURPOSE: The synergistic use of k-t undersampling and multiband (MB) imaging has the potential to provide extended slice coverage and high spatial resolution for first-pass perfusion MRI. The low-rank plus sparse (L + S) model has shown excellent performance for accelerating single-band (SB) perfusion MRI. METHODS: A MB data consistency method employing ESPIRiT maps and through-plane coil information was developed. This data consistency method was combined with the temporal L + S constraint to form the slice-L + S method. Slice-L + S was compared to SB L + S and the sequential operations of split slice-GRAPPA and SB L + S (seq-SG-L + S) using synthetic data formed from multislice SB images. Prospectively k-t undersampled MB data were also acquired and reconstructed using seq-SG-L + S and slice-L + S. RESULTS: Using synthetic data with total acceleration rates of 6-12, slice-L + S outperformed SB L + S and seq-SG-L + S (N = 7 subjects) with respect to normalized RMSE and the structural similarity index (P < 0.05 for both). For the specific case with MB factor = 3 and rate 3 undersampling, or for SB imaging with rate 9 undersampling (N = 7 subjects), the normalized RMSE values were 0.037 ± 0.007, 0.042 ± 0.005, and 0.031 ± 0.004; and the structural similarity index values were 0.88 ± 0.03, 0.85 ± 0.03, and 0.89 ± 0.02 for SB L + S, seq-SG-L + S, and slice-L + S, respectively (P < 0.05 for both). For prospectively undersampled MB data, slice-L + S provided better image quality than seq-SG-L + S for rate 6 (N = 7) and rate 9 acceleration (N = 7) as scored by blinded experts. CONCLUSION: Slice-L + S outperformed SB-L + S and seq-SG-L + S and provides 9 slice coverage of the left ventricle with a spatial resolution of 1.5 mm × 1.5 mm with good image quality.


Asunto(s)
Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Perfusión
4.
Herz ; 44(8): 735-742, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30324340

RESUMEN

OBJECTIVE: Cardiovascular magnetic resonance imaging (CMR) has been established as a modality to detect myocardial viability. The aim of this study was to evaluate myocardial viability by observing transmural extent of infraction and microvascular perfusion level. METHODS: We performed CMR in 30 myocardial infarction (MI) patients within 7-10 days. At the 6­month follow-up, CMR was used to evaluate the impact of abnormal reperfusion and observe the transmural extent of infraction on recovery of function. RESULTS: The left ventricle was divided into 16 segments using the American Heart Association classification. Infarcts were detected in 202 of the 480 segments (42%) by delayed enhancement magnetic resonance imaging (DE-MRI). According to first-pass myocardial perfusion, abnormal perfusion was detected in 278 of 480 segments (60%), reduced perfusion was identified in 173 of 278 (62%), and perfusion defects in 105 of 278 segments (38%). The results showed that the segments with abnormal perfusion were larger than in DE-MRI (P < 0.05), indicating that the area of abnormal perfusion segments extend significantly beyond the region of infarction. Microvascular perfusion with an infarcted region was lower compared to non-infarcted segments (P < 0.05). The extent of myocardial hyperenhancement correlated inversely with microvascular perfusion (P < 0.05). Segments with severe microvascular perfusion and >75% transmural infarction on the 7­ to 10-day scan had markedly increased at the 6­month follow-up (P < 0.01), indicating a lack of recovery of cardiac function. CONCLUSIONS: DE-MRI combined with microvascular perfusion may be effective to detect viable myocardium in patients with MI and may provide a means of predicting whether revascularization will be effective.


Asunto(s)
Corazón , Imagen por Resonancia Magnética , Infarto del Miocardio , Medios de Contraste , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Ventrículos Cardíacos , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Infarto del Miocardio/complicaciones , Miocardio
5.
J Cardiovasc Magn Reson ; 19(1): 11, 2017 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-28125995

RESUMEN

BACKGROUND: Whole-heart first-pass perfusion cardiovascular magnetic resonance (CMR) relies on highly accelerated image acquisition. The influence of undersampling on myocardial blood flow (MBF) quantification has not been systematically investigated yet. In the present work, the effect of spatiotemporal scan acceleration on image reconstruction accuracy and MBF error was studied using a numerical phantom and validated in-vivo. METHODS: Up to 10-fold scan acceleration using k-t PCA and k-t SPARSE-SENSE was simulated using the MRXCAT CMR numerical phantom framework. Image reconstruction results were compared to ground truth data in the k-f domain by means of modulation transfer function (MTF) analysis. In the x-t domain, errors pertaining to specific features of signal intensity-time curves and MBF values derived using Fermi model deconvolution were analysed. In-vivo first-pass CMR data were acquired in ten healthy volunteers using a dual-sequence approach assessing the arterial input function (AIF) and myocardial enhancement. 10x accelerated 3D k-t PCA and k-t SPARSE-SENSE were compared and related to non-accelerated 2D reference images. RESULTS: MTF analysis revealed good recovery of data upon k-t PCA reconstruction at 10x undersampling with some attenuation of higher temporal frequencies. For 10x k-t SPARSE-SENSE the MTF was found to decrease to zero at high spatial frequencies for all temporal frequencies indicating a loss in spatial resolution. Signal intensity-time curve errors were most prominent in AIFs from 10x k-t PCA, thereby emphasizing the need for separate AIF acquisition using a dual-sequence approach. These findings were confirmed by MBF estimation based on AIFs from fully sampled and undersampled simulations. Average in-vivo MBF estimates were in good agreement between both accelerated and the fully sampled methods. Intra-volunteer MBF variation for fully sampled 2D scans was lower compared to 10x k-t PCA and k-t SPARSE-SENSE data. CONCLUSION: Quantification of highly undersampled 3D first-pass perfusion CMR yields accurate MBF estimates provided the AIF is obtained using fully sampled or moderately undersampled scans as part of a dual-sequence approach. However, relative to fully sampled 2D perfusion imaging, intra-volunteer variation is increased using 3D approaches prompting for further developments.


Asunto(s)
Circulación Coronaria , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Isquemia Miocárdica/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Adulto , Velocidad del Flujo Sanguíneo , Estudios de Factibilidad , Análisis de Fourier , Voluntarios Sanos , Humanos , Imagen por Resonancia Magnética/instrumentación , Modelos Cardiovasculares , Isquemia Miocárdica/fisiopatología , Imagen de Perfusión Miocárdica/instrumentación , Análisis Numérico Asistido por Computador , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Adulto Joven
6.
Magn Reson Med ; 75(6): 2315-23, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26148638

RESUMEN

PURPOSE: To develop an accurate method of performing free-breathing coil calibration for application to parallel imaging reconstructions of dynamic single-shot datasets. METHODS: Coil calibration data are produced through acquisition of multiple prescans before the accelerated scan, applied during free-breathing. These multiple free-breathing prescans (MFPs) provide the necessary coil information for accurate parallel imaging reconstruction of each accelerated frame of a dynamic series, under guidance of an appropriate respiratory position based matching algorithm. This is investigated in myocardial first-pass perfusion with retrospectively undersampled datasets for analysis with standard calibration techniques to guide prospectively undersampled experiments for specific demonstration of performance against a range of "temporal" calibration techniques. RESULTS: Reconstruction of the retrospectively subsampled datasets with MFP-calibrated parallel imaging showed significant improvements in relative root-mean-square error comparative to all other techniques (all P < 0.05; n = 6) for acceleration factors R > 3. Accelerated acquisitions, reconstructed by means of various temporal calibration techniques and analyzed by visual observer artifact scoring, also demonstrated a large improvement with use of MFPs. Artifact levels were reduced from an average of 2.5 ± 0.6 for the best performing implementation of TGRAPPA to 0.8 ± 0.4 for MFP-GRAPPA (P < 0.001; n = 20) (0 = none to 4 = strong, nondiagnostic). CONCLUSION: MFP as parallel imaging coil calibration data can give improved performance in free-breathing dynamic MR while maintaining maximal acceleration. Magn Reson Med 75:2315-2323, 2016. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Mecánica Respiratoria/fisiología , Algoritmos , Calibración , Bases de Datos Factuales , Humanos , Movimiento/fisiología
7.
Magn Reson Med ; 71(1): 133-44, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23440705

RESUMEN

PURPOSE: To describe and characterize a new approach to first-pass myocardial perfusion utilizing balanced steady-state free precession acquisition without the use of saturation recovery or other magnetization preparation. THEORY: The balanced steady-state free precession sequence is inherently sensitive to contrast agent enhancement of the myocardium. This sensitivity can be used to advantage in first-pass myocardial perfusion imaging by eliminating the need for magnetization preparation. METHODS: Bloch equation simulations, phantom experiments, and in vivo 2D imaging studies were run comparing the proposed technique with three other methods: saturation recovery spoiled gradient echo, saturation recovery steady-state free precession, and steady-state spoiled gradient echo without magnetization preparation. Additionally, an acquisition-reconstruction strategy for 3D perfusion imaging is proposed and initial experience with this approach is demonstrated in healthy subjects and one patient. RESULTS: Phantom experiments verified simulation results showing the sensitivity of the balanced steady-state free precession sequence to contrast agent enhancement in solid tissue is similar to that of magnetization-prepared acquisitions. Images acquired in normal volunteers showed the proposed technique provided superior signal and signal-to-noise ratio compared with all other sequences at baseline as well as postcontrast. CONCLUSIONS: A new approach to first-pass myocardial perfusion is presented that obviates the need for magnetization preparation and provides high signal-to-noise ratio.


Asunto(s)
Algoritmos , Vasos Coronarios/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Humanos , Aumento de la Imagen/métodos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA