Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
BMC Surg ; 24(1): 122, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38658932

RESUMEN

Various studies have focused on the application of fibrin sealants (FS) in thyroid surgery. Utilizing a meta-analysis, this systematic review analyzed the findings of recent randomized controlled trials on the safety and efficacy of FS in patients who underwent thyroidectomy. The Cochrane Library, Web of Science, Embase, PubMed, and Medline databases were searched for relevant studies, without any language restrictions. Seven randomized controlled trials were included in the originally identified 69 studies. Overall, 652 patients received FS during thyroid surgery; their outcomes were compared with those of conventionally treated patients. The primary outcomes were total volume of wound drainage, length of hospitalization, and operative time. Significant differences were observed in the total volume of wound drainage (mean deviation (MD): -29.75, 95% confidence interval (CI): -55.39 to -4.11, P = 0.02), length of hospitalization (MD: -0.84, 95% CI: -1.02 to -0.66, P < 0.00001), and surgery duration (MD: -7.60, 95% CI: -14.75 to -0.45, P = 0.04). Secondary outcomes were seroma and hypoparathyroidism development. The risk of hypoparathyroidism did not differ between the FS and conventional groups (I = 0%, relative risk = 1.31, P = 0.38). Analysis of "seroma formation that required invasive treatment" indicated that FS showed some benefit (I2 = 8%, relative risk 0.44, P = 0.15). Heterogeneity among the different trials limited their conclusions. The meta-analysis showed that although FS use did not significantly reduce seroma or hypoparathyroidism incidence in patients after thyroidectomy, it significantly reduced the total drainage volume, length of hospitalization, and duration of surgery.


Asunto(s)
Adhesivo de Tejido de Fibrina , Tiroidectomía , Humanos , Tiroidectomía/efectos adversos , Tiroidectomía/métodos , Adhesivo de Tejido de Fibrina/uso terapéutico , Resultado del Tratamiento , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/epidemiología , Tiempo de Internación/estadística & datos numéricos , Ensayos Clínicos Controlados Aleatorios como Asunto , Tempo Operativo , Adhesivos Tisulares/uso terapéutico
2.
Clin Plast Surg ; 50(1): 163-170, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36396255

RESUMEN

Advantages of standard endoscopic surgery include diminished incidence of scarring, numbness, bleeding, and edema, making endoscopic surgery preferable to the conventional suprapubic approach. Endoscopic-assisted abdominoplasty can also treat diastasis recti deformity with minimal excess skin. For enhanced results, a learning curve is expected to achieve optimal technical expertise.


Asunto(s)
Abdominoplastia , Humanos , Abdominoplastia/métodos , Endoscopía/métodos , Cicatriz
3.
Indian J Ophthalmol ; 70(6): 1971-1974, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35647964

RESUMEN

Purpose: In this study, our aim was to investigate if fibrin adhesives used in conjunctival wound surgery with autologous conjunctival grafts could be used repeatedly at different times after surgical opening. Methods: 40 New Zealand rabbits were used in the study. These animals were divided into four groups, each consisting of 10 rabbits, and hence 20 eyes. In the first group (control group), Tisseel fibrin sealant was used on the day the eye was first opened surgically; in the second group, it was used on the seventh day; on the third group, it was used on the 14th day; and in the fourth group, it was used 28 days after surgical opening. The graft from the inferior bulbar conjunctiva was attached using Tisseel fibrin glue to the superior scleral bed at the location where the superior bulbar conjunctiva was excised in the same eye. Results: No microbial growth was detected in the cultures of the samples tested. There were two partial graft loss in group 2 and there was one partial graft loss in each group of the other groups, and further total graft loss was present in one rabbit in group 3. None of the rabbits had any complications like granuloma, Corneal dellen or infection. Conclusion: Based on these results, fibrin sealants can be used repeatedly by storing them at room temperature. Repeated use of fibrin adhesives will reduce the cost of ophthalmologic surgeries and non-ophthalmologic surgeries.


Asunto(s)
Adhesivo de Tejido de Fibrina , Pterigion , Animales , Conjuntiva/trasplante , Adhesivo de Tejido de Fibrina/farmacología , Humanos , Complicaciones Posoperatorias , Pterigion/cirugía , Conejos , Temperatura , Trasplante Autólogo
4.
J Clin Neurosci ; 89: 151-157, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34119260

RESUMEN

Hemostasis represents a fundamental step in every surgical procedure. During neurosurgical procedures, proper and robust hemostasis into confined spaces can significantly reduce the odds of perioperative complications. Over the decades, multiple methods have been applied, and several medical devices have been developed to promote and guarantee proper hemostasis. This study presents a systematic review of the most used intraoperative hemostatic methods and devices in neurosurgery. Insightful research was performed on the PubMed database according to the PRISMA guidelines. This comprehensive review of scientific literature represents a synoptic panel where the most used intraoperative hemostatic methods and devices available today in neurosurgery are classified and described.


Asunto(s)
Hemostasis Quirúrgica/métodos , Hemostasis/efectos de los fármacos , Hemostáticos/uso terapéutico , Procedimientos Neuroquirúrgicos/métodos , Hemostasis/fisiología , Hemostáticos/farmacología , Humanos , Enfermedades del Sistema Nervioso/tratamiento farmacológico , Enfermedades del Sistema Nervioso/cirugía
5.
Obes Surg ; 31(3): 1158-1167, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33145716

RESUMEN

BACKGROUND: Complications including staple-line leakage and bleeding may occur after sleeve gastrectomy and Roux-en-Y gastric bypass. In this meta-analysis, the efficacy of fibrin sealant in strengthening the staple line and reducing complication risk after bariatric surgery was evaluated. METHODS: We searched PubMed, Embase, and Cochrane Library databases for randomized controlled trials (RCTs) published up to October 2020. Pooled estimates of the outcomes were computed using a random effects model. The primary outcomes were bleeding and leakage; secondary outcomes were gastric stricture, length of hospital stay, reoperation rate, and total operation time. RESULTS: In total, 9 RCTs including 2136 patients were reviewed. Our meta-analysis revealed that compared with controls, fibrin sealants decreased incidence of bleeding significantly (risk ratio [RR] = 0.42; 95% confidence interval [CI], 0.18-0.97), but did not demonstrate significant differences in reducing the incidence of leakage (RR = 0.62; 95% CI, 0.23-1.73), gastric stricture (RR = 1.16; 95% CI, 0.46-2.91), reoperation rate (RR = 0.85; CI, 0.14-5.14), or length of hospital stay (weighted mean difference = 0.62; 95% CI, - 0.31 to 1.55). Compared with oversewing, fibrin sealant use reduced the operation time; however, their efficacies in reducing the incidence of postoperative bleeding and leakage did not differ significantly. CONCLUSIONS: Although applying fibrin sealants to the staple line in bariatric surgery may provide favorable results, but it may not reduce postoperative leakage and stricture incidence significantly. Nevertheless, the application of fibrin sealants as a method for reducing risks of complications after bariatric surgery warrant further investigation.


Asunto(s)
Adhesivo de Tejido de Fibrina , Obesidad Mórbida , Adhesivo de Tejido de Fibrina/uso terapéutico , Gastrectomía , Humanos , Obesidad Mórbida/cirugía , Complicaciones Posoperatorias/prevención & control , Reoperación
6.
J Invest Surg ; 32(3): 257-261, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29260920

RESUMEN

PURPOSE: Fibrin sealants are used for hemostasis during surgery. Commercially available fibrin sealants are made of materials of human or animal origin. We developed a novel recombinant fibrin sealant patch (KTF-374) that has thin and flexible properties. This study evaluated the hemostatic efficacy of KTF-374 for various patterns of bleeding in rabbits, as compared with that of the existing fibrin-coated collagen fleece (FCCF). MATERIALS AND METHODS: Test hemostats used were KTF-374 and FCCF. Laparotomy was performed under general anesthesia in rabbits. We created wounds in the liver, caudal vena cava, and ventral aorta under anticoagulating conditions with heparin. Test hemostats were then applied to the wound site and compressed manually for 3 min. Hemostatic efficacy was evaluated with the success rate of hemostasis at 3 min. RESULTS: In all bleeding models, the success rate of hemostasis was significantly higher with KTF-374 than FCCF. The hemostatic success rate of KTF-374 and FCCF was 100% vs. 25% (p = .007) in the partial hepatectomy model (n = 8); 100% vs. 12.5% (p = .001) in the caudal vena cava resection model (n = 8); and 100% vs. 25% (p = .004) in the ventral aortic puncture model (n = 8). The wound site could clearly be recognized through the patch after the application of KTF-374 but not FCCF. CONCLUSIONS: These results suggest that KTF-374 possesses more potent hemostatic properties than FCCF for various patterns of bleeding. KTF-374 is a promising hemostat due to its potent efficacy and good visibility of the wound site through the patch.


Asunto(s)
Adhesivo de Tejido de Fibrina , Hemostáticos , Animales , Hemorragia , Hemostasis/efectos de los fármacos , Hemostasis Quirúrgica , Humanos , Conejos
7.
Adv Clin Exp Med ; 27(6): 857-862, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29938935

RESUMEN

This review article describes the use of fibrin glue or fibrin sealants and their development over the past 5 years, with a focus on cardiac surgery. The roles of various types of sealants that are available in hemostasis control are reviewed briefly, together with the various potential risks and side effects of their use. The results of experimental work reported during the last 5 years, clinical data from the same period and the safety aspects of fibrin-based glues and sealants are summarized, showing many advantages of their clinical application over the use of synthetic glues or sealants that may be stronger in some cases, but less safe. It can be concluded that the widespread use of fibrin sealants is fully justified, as it benefits the patient as well as the surgeon through the improved control of hemostasis without increasing any adverse effects or complications during surgical procedures.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Adhesivo de Tejido de Fibrina/uso terapéutico , Humanos
8.
J Cardiothorac Vasc Anesth ; 31(3): 876-882, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28320573

RESUMEN

OBJECTIVES: To compare the clinical and economic outcomes of EVICEL (Ethicon, Inc., Somerville, NJ) and TISSEEL (Baxter Healthcare Corporation, Westlake Village, CA) use in patients undergoing primary coronary artery bypass graft (CABG) surgery. DESIGN: Retrospective database analysis. SETTING: Premier prospective hospital database (June 2009 through March 2014) covering approximately 20% of hospital discharges in the United States. PARTICIPANTS: Adults undergoing primary CABG surgery who received either EVICEL or TISSEEL on the day of surgery (index date). INTERVENTIONS: Two intervention groups were formed, EVICEL and TISSEEL. Clinical outcomes compared included postoperative bleeding complications (International Classification of Diseases, Ninth Revision, Clinical Modification code: 998.1) and number of blood transfusions received on the index day. Economic outcomes compared included hospital length of stay, hospital costs, and 30-day readmission rates. Propensity-score matching was used to control for patient and hospital characteristics. MEASUREMENTS AND MAIN RESULTS: A total of 129,014 primary CABG surgery patients were identified; 986 patients (mean age: 64 years, 73% male) received EVICEL and 6,340 patients (mean age: 65 years, 75% male) received TISSEEL on the index day. After propensity-score matching, patients who received EVICEL compared with TISSEEL had significantly fewer postoperative bleeding complications (3.0% v 5.0%, p = 0.0197), index-day blood transfusion rates (19% v 34%, p<0.0001), readmission rates (18% v 32%, p<0.0001), and costs ($40,736 [standard deviation $19,465] v $46,005 [standard deviation $24,049], p<0.0001). Results from a sensitivity analysis using a generalized linear model to control for other hemostatic agent use also favored EVICEL over TISSEEL. CONCLUSION: Results from this real-world retrospective database analysis showed fewer bleeding complications and lower costs in patients undergoing primary CABG surgery who received EVICEL compared with TISSEEL.


Asunto(s)
Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/tendencias , Adhesivo de Tejido de Fibrina/efectos adversos , Hemorragia/epidemiología , Readmisión del Paciente/tendencias , Complicaciones Posoperatorias/epidemiología , Anciano , Bases de Datos Factuales/tendencias , Femenino , Hemorragia/diagnóstico , Hemorragia/etiología , Hemostáticos/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Estudios Retrospectivos , Estados Unidos/epidemiología
9.
Surg Endosc ; 31(3): 1350-1353, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27444826

RESUMEN

BACKGROUND: Non-penetrating mesh fixation is becoming widely accepted even though little is known about the short-term fixation strength of these techniques. Although clinical outcomes are the ultimate measure of effectiveness, ex vivo biomechanical evaluation provides insights about the load-carrying capacity of the mesh-tissue complex in vivo. As such, the purpose of this study was to compare the short-term fixation strength of three unique non-penetrating methods of fixation: LifeMesh™, ProGrip™, and Tisseel™. Among these, LifeMesh™ is a novel technology where large-pore, mid-weight polypropylene mesh is embedded in a dry matrix of porcine gelatin and microbial transglutaminase enzyme, providing self-fixation without the need for a separate adhesive application. METHODS: Seven mongrel swine underwent implantation of two 4 × 7 cm pieces of either LifeMesh™, ProGrip™, or polypropylene mesh fixated with 2 mL of Tisseel™; 10 min after application, the samples were excised with the abdominal wall and stored for immediate biomechanical testing. The samples underwent lap shear testing to determine the short-term fixation strength of these three technologies. RESULTS: ProGrip™ demonstrated mean fixation strength of 1.3 N/cm (±STE 0.2). Mean fixation for mesh fixated with Tisseel™ was 2.6 N/cm (±STE 0.5). LifeMesh™ samples had mean fixation strength of 8.0 N/cm (±STE 2.1). Analysis of variance testing showed that interfacial strength of LifeMesh™ was significantly greater than that of either ProGrip™ or Tisseel™. ProGrip™ and Tisseel™ were not significantly different from each other (p = 0.06). CONCLUSIONS: Short-term strength of mesh fixation is an undescribed factor in hernia repair, but could have significant implications for early recurrence and mesh contraction. While further investigation is needed to define adequate interfacial strength, this comparison of non-penetrating mesh fixation methods shows that the novel LifeMesh™ technology exhibits greater strength than other non-penetrating fixation techniques.


Asunto(s)
Herniorrafia/instrumentación , Herniorrafia/métodos , Ensayo de Materiales , Mallas Quirúrgicas , Animales , Fenómenos Biomecánicos , Modelos Animales , Polipropilenos , Porcinos
10.
J Minim Invasive Gynecol ; 23(7): 1167-1171, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27590570

RESUMEN

STUDY OBJECTIVE: To evaluate factors associated with the use of hemostatic agents during traditional laparoscopic or robotic hysterectomy. DESIGN: A retrospective cohort trial (Canadian Task Force classification III). SETTING: A single medical center in Cincinnati, OH, from August 1, 2013, to July 31, 2014. PATIENTS: Women undergoing traditional laparoscopic or robotic hysterectomies with and without the use of hemostatic agents. INTERVENTION: The use of a hemostatic agent at the time of hysterectomy. MEASUREMENTS: Patient characteristics and pre- and postoperative metrics were recorded for each subject. Associations between categoric variables were analyzed using chi-square testing, whereas continuous variables were analyzed using analysis of variance. Modeling of study variables to predict hemostatic agent use was performed using chi-square-assisted interaction detection methods. MAIN RESULTS: The study sample included 176 cases performed by 30 surgeons. In our sample, 42% of minimally invasive hysterectomies were performed with the surgical robot (robotic-assisted laparoscopic hysterectomy); the remainder of minimally invasive hysterectomies by approach was as follows: total laparoscopic hysterectomy, 27%; laparoscopic-assisted vaginal hysterectomy, 16%; and laparoscopic supracervical hysterectomy, 15%. Forty-six percent (81/176) of cases recorded the use of a fibrin hemostat, 26% (46/176) involved an alternative hemostat, and 28% (49/176) of cases did not use any hemostat. By surgical approach, no hemostatic agent use was noted most often among laparoscopic-assisted hysterectomy; alternative hemostats were most often used during total laparoscopic hysterectomy. Robotic-assisted laparoscopic hysterectomy and laparoscopic supracervical hysterectomy were most often associated with fibrin-based hemostats. The use of any hemostatic agent did not result in clinical significant blood loss relative to cases in whino product was used. The study variable identified most predictive of hemostat use by the chi-square-assisted interaction detection regression tree model was surgeon identity. CONCLUSION: Hemostatic agent use during traditional laparoscopic and robotic hysterectomy does not appear to be associated with operative bleeding but is related to surgeon identity.


Asunto(s)
Hemostáticos/administración & dosificación , Histerectomía , Hemorragia Posoperatoria/prevención & control , Pautas de la Práctica en Medicina , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Histerectomía/métodos , Laparoscopía/métodos , Persona de Mediana Edad , Ohio , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos
11.
J Invest Surg ; 29(6): 352-358, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27191688

RESUMEN

BACKGROUND: Previous studies investigated the efficacy and applicability of tissue adhesives in gastrointestinal surgery while no evidence is available to date about a novel compound, TachoSil (Takeda, Zurich, Switzerland). The primary aim of this observational study was to assess the effect of new fibrin sealant on the incidence of postoperative complications in a homogeneous group of patients submitted to upper gastrointestinal surgery for cancer. METHODS: Two cohorts of 28 and 34 patients undergoing upper gastrointestinal for surgery were compared. In the first cohort, the anastomotic site was treated with TachoSil fibrinogen-thrombin-collagen patches and in the second no collagen sponge or any other hemostatic sealant was used. Postoperative complications and outcomes as well as postoperative biochemical parameters were analyzed. RESULTS: Postoperative complications occurred in 12 patients (35.3%) and 2 patients (7.1%) in control and collagen sponge group respectively (χ2 = 3.539, p < 0.05), with no anastomotic leakage in the collagen sponge group. A binary logistic regression analysis showed that the nonuse of collagen sponge [odds ratio (OR) = 0.025, 95% confidence interval (CI) = 0.001-0.457, p = 0.01] was independently associated with postoperative complication occurrence. CONCLUSIONS: The addition of fibrinogen-thrombin-collagen sponge patch may reduce postoperative complication rate after upper gastrointestinal surgery for cancer. Further study to delineate the role of TachoSil in gastrointestinal surgery are also needed to demonstrate improved effectiveness and applicability.


Asunto(s)
Fibrinógeno/administración & dosificación , Gastrectomía/métodos , Hemostasis Quirúrgica/métodos , Hemorragia Posoperatoria/prevención & control , Trombina/administración & dosificación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Gastrectomía/efectos adversos , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Hemorragia Posoperatoria/epidemiología , Hemorragia Posoperatoria/etiología , Neoplasias Gástricas/cirugía , Tapones Quirúrgicos de Gaza , Adulto Joven
12.
J Plast Surg Hand Surg ; 50(1): 59-62, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26541641

RESUMEN

BACKGROUND: Latissimus dorsi flap (LD) is used in breast reconstruction procedures, although prolonged donor site drainage is a frequent complication. To decrease this problem, quilting sutures and/or fibrin sealants were proposed, with alternate results. The primary objective of this study was to assess the effectiveness of Tisseel® in association with the Harmonic Synergy® blade system to reduce this complication. MATERIALS AND METHODS: Between 2010-2012, 20 consecutive patients undergoing immediate unilateral breast reconstruction with LD were enrolled in the study (Group A) and matched with 20 patients in which LD was raised with electrocautery (Group B), and 20 patients in which LD was harvested with Harmonic® (Group C). After informed consent acquisition, Harmonic® was used in Group A for LD harvesting, but differed from other groups as fibrin glue was applied to the donor site prior to closure. In all groups donor site drainage measurements at 24 and 48 hours, total drain volume, days to drain removal, operation time, and complication rate were recorded. Pearson's Chi-squared, ANOVA, and Bonferroni post-hoc tests were used to analyze the data. RESULTS: Data analysis did not show any statistical difference. Prolonged drains output ≥ 15 days occurred in one patient of Group A and C, and in three Group B patients. CONCLUSION: Although the combined use of Harmonic® and Tisseel® presents a low donor site fluid collection rate, the fibrin glue seems not to have further beneficial effects in reducing the post-operative serous drainage or to lead to an early drain removal when compared to Harmonic® only.


Asunto(s)
Adhesivo de Tejido de Fibrina/uso terapéutico , Mamoplastia , Músculos Superficiales de la Espalda/trasplante , Colgajos Quirúrgicos , Adhesivos Tisulares/uso terapéutico , Terapia por Ultrasonido/instrumentación , Adulto , Anciano , Electrocoagulación , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Sitio Donante de Trasplante
13.
Eur J Trauma Emerg Surg ; 41(5): 493-500, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26037982

RESUMEN

INTRODUCTION: Uncontrolled haemorrhage as a result of trauma remains a significant surgical challenge, accounting for approximately 25-40% of trauma-related mortality. A wide range of local internal haemostatic agents have been developed to help achieve intra-cavity control of bleeding, with choice of agent influenced by the circumstances and nature of the haemorrhage. Trauma patients are frequently coagulopathic, so products that incorporate pro-coagulant technology and thereby act independently of the clotting cascade may be more effective in these settings. A range of products that utilise thrombin and fibrinogen to promote local haemostasis at intra-cavity bleeding points are available or in development, including fibrin glues (e.g. Tisseel®/Tissucol® and Evicel®/Crosseal®/Quixil®), fibrin sealant patches (e.g. TachoSil®) and products based on a gelatin-thrombin haemostatic matrix (e.g. FloSeal®). MATERIALS AND METHODS: This systematic review was performed to assess all peer-reviewed evidence of product efficacy. RESULTS: Fibrin sealant patches have shown haemostatic efficacy in a variety of surgical procedures and appear to offer practical advantages over liquid fibrin glues. Existing evidence suggests that patch products enable delivery of pro-coagulants to defined areas with less chance of dilution and/or displacement by blood flow, but they require a pressure buttress for a suitable amount of time to achieve good results after trauma. CONCLUSIONS: Our experience, supported by other reports in the literature, suggests the use of such fibrin patches may provide an effective option in helping to control haemorrhage after trauma. However, there is a general paucity of clinical data for intra-cavity haemostatic agent use, with the majority of data being based on animal models and case reports. Further clinical evidence, ideally including comparative studies between different agents, would be beneficial in helping guide surgeon choice to the most appropriate products to use in trauma settings.


Asunto(s)
Hemorragia/prevención & control , Hemostáticos/uso terapéutico , Animales , Vendajes , Modelos Animales de Enfermedad , Adhesivo de Tejido de Fibrina/uso terapéutico , Gelatina/administración & dosificación , Humanos , Resultado del Tratamiento
14.
J Arthroplasty ; 29(8): 1516-20, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24674732

RESUMEN

An RCT was conducted to ascertain whether, compared to control management, topical application of a novel fibrin sealant (Evicel, J&J) in patients undergoing primary TKA reduces peri-operative blood loss. Sixty-two patients were randomized to receive topical application of Evicel (N = 31) or not (N = 31). The mean total blood loss was 1.9L(± 0.7) in the control group and 1.8L(± 0.5) in the treatment group (P = 0.4). The transfusion rate was 32.3% in the control group and 25.8% in the treatment group (P = 0.5). The transfusion rate decreased linearly with increasing preoperative Hb levels in the treatment group (P = 0.005). The results of this study suggest that topical application of this novel fibrin sealant doesn't reduce perioperative blood loss and the need for allogeneic blood transfusion.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Pérdida de Sangre Quirúrgica/prevención & control , Adhesivo de Tejido de Fibrina/uso terapéutico , Hemostáticos/uso terapéutico , Hemorragia Posoperatoria/prevención & control , Anciano , Transfusión Sanguínea , Femenino , Hemoglobinas/metabolismo , Humanos , Tiempo de Internación , Modelos Logísticos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
15.
Artículo en Inglés | MEDLINE | ID: mdl-24222983

RESUMEN

BACKGROUND: The aim of this study was to compare the effects of two types of fibrin glue in patients undergoing facelift surgery. METHODS: A prospective, controlled "right-left side" study was carried out in 20 patients. The two fibrin sealants used were Quixil® and Tissucol®. The two sealants were used at the same time, ie, one on one side of the face and the other on the contralateral side. Comparisons were made with regard to rates of hematoma and seroma, degree of induration, edema, ecchymosis, pain levels, and patient satisfaction. RESULTS: The results were almost equivalent. The only exception was a significant (40 mL) hematoma in a patient treated with Quixil. Bleeding was most likely due to a sudden rise in blood pressure during the immediate postoperative period. However, it must be emphasized that, while Tissucol actually seals the undermined area, thus virtually eliminating the dead space, Quixil acts differently, in that its effectiveness in preventing hematoma is linked mainly to its hemostatic effect. CONCLUSION: The two fibrin sealants used were nearly identical with regard to patient safety and quality of the result. Nevertheless, it is noted that, while Tissucol has both hemostatic and "gluing" effects, Quixil is mainly effective in securing hemostasis.

16.
Surg Neurol Int ; 4(Suppl 5): S301-17, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24163783

RESUMEN

BACKGROUND: In spinal surgery, cerebrospinal fluid (CSF) fistulas attributed to deliberate dural opening (e.g., for tumors, shunts, marsupialization of cysts) or inadvertent/traumatic dural tears (DTs) need to be readily recognized, and appropriately treated. METHODS: During spinal surgery, the dura may be deliberately opened to resect intradural lesions/tumors, to perform shunts, or to open/marsupialize cysts. DTs, however, may inadvertently occur during primary, but are seen more frequently during revision spinal surgery often attributed to epidural scarring. Other etiologies of CSF fistulas/DTs include; epidural steroid injections, and resection of ossification of the posterior longitudinal ligament (OPLL) or ossification of the yellow ligament (OYL). Whatever the etiology of CSF fistulas or DTs, they must be diagnosed utilizing radioisotope cisternography (RIC), magnetic resonance imaging (MRI), computed axial tomography (CT) studies, and expeditiously repaired. RESULTS: DTs should be repaired utilizing interrupted 7-0 Gore-Tex (W.L. Gore and Associates Inc., Elkton, MD, USA) sutures, as the suture itself is larger than the needle; the larger suture occludes the dural puncture site. Closure may also include muscle patch grafts, dural patches/substitutes (bovine pericardium), microfibrillar collagen (Duragen: Integra Life Sciences Holdings Corporation, Plainsboro, NJ), and fibrin glues or dural sealants (Tisseel: Baxter Healthcare Corporation, Deerfield, IL, USA). Only rarely are lumbar drains and wound-peritoneal and/or lumboperitoneal shunts warranted. CONCLUSION: DTs or CSF fistulas attributed to primary/secondary spinal surgery, trauma, epidural injections, OPLL, OYL, and other factors, require timely diagnosis (MRI/CT/Cisternography), and appropriate reconstruction.

17.
Turk J Haematol ; 29(1): 40-7, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24744622

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the efficiency of two local hemostatic agents administered with apreoperative dose of replacement therapy in patients with bleeding disorders undergoing oral surgery. MATERIAL AND METHODS: The study included 21 patients that were randomly divided into 3 groups. Patients in Group1 (n = 7) received preoperative replacement therapy and postoperative fibrin sealant applied to the surgical site. Patientsin Group 2 (n = 7) received preoperative replacement therapy and postoperative tissue adhesive applied to the surgicalsite. Patients in Group 3 (n = 7) were given replacement therapy pre- and postoperatively. RESULTS: Postoperative bleeding was not observed in 17 of the 21 patients, including 5 in Group 1 (71.42%), 6 in Group2 (85.71%), and 6 in Group 3 (85.71%). Hemorrhagic complications occurred in only 4 of the 21 patients. CONCLUSION: The use of fibrin sealant and tissue adhesive was beneficial, as they reduced the level of factor concentratesused for replacement therapy and resulted in rapid hemostasis at the surgical site, facilitating the ability to performserial surgical procedures concurrently.

18.
Eur J Trauma Emerg Surg ; 38(1): 33-6, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26815670

RESUMEN

INTRODUCTION: The development of fibrin sealants has been progressing; they are now often applied as fibrinogen-coated collagen patches. MATERIALS AND METHODS: The concept has been increasingly applied in hepato-pancreato-biliary surgery, for example, following liver resection, and to some extent also in pancreatic surgery, both in order to reinforce the pancreatic anastomosis at pancreaticoduodenectomy and to seal the pancreatic stump following distal pancreatectomy. CONCLUSION: High quality evidence in the form of major prospective, randomized clinical studies is still lacking on in the field of HPB. There is also an the absence of proper cost-utility analyses.

19.
J Maxillofac Oral Surg ; 10(1): 45-9, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22379320

RESUMEN

Platelets play a crucial role in hemostasis and wound healing, platelet growth factors are well known source of healing cytokines. Numerous techniques of autologous platelet concentrates have been developed and applied in oral and maxillofacial surgery. This review describes the evolution of the first and second generation of platelet concentrates (platelet rich plasma and platelet rich fibrin respectively) from their fore runner-fibrin sealants.

20.
Artículo en Coreano | WPRIM (Pacífico Occidental) | ID: wpr-172346

RESUMEN

PURPOSE: The surgical treatment of burn patient is associated with substantial blood loss. Therefore, multiple hemostatic techniques have been proposed for this problem. Unfortunately, a clear conclusion as to the best hemostatic agent cannot be made. Then, we present our experience of using Fibrin sealant (TISSEEL(TM)) in extremity operation. METHODS: We reviewed the medical records of 10 patients treated in our burn center who conducted the extremity operation using Fibrin sealant from January 2010 to December 2010. RESULTS: The mean tourniquet time is within 60 minutes and no need of transfusion during the operation in all patients. The average take rate for skin graft is over the 98%. No one has nerve injury and other problems. CONCLUSION: Fibrin sealant is a human derived factors that are designed to reproduce the final step of the physiologic coagulation cascade of a stable fibrin clot. In addition, Fibrin sealant has the advantage of being biocompatible and biodegradable, without inducing inflammation, foreign body reaction, and tissue necrosis. Fibrin sealant is shown to be effective methods to achieve hemostasis for the extremity burn surgery.


Asunto(s)
Humanos , Unidades de Quemados , Quemaduras , Extremidades , Fibrina , Adhesivo de Tejido de Fibrina , Reacción a Cuerpo Extraño , Hemostasis , Técnicas Hemostáticas , Imidazoles , Inflamación , Registros Médicos , Necrosis , Nitrocompuestos , Piel , Torniquetes , Trasplantes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA