Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Sensors (Basel) ; 24(15)2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39124006

RESUMEN

Salinity is a very important parameter from an environmental perspective, and therefore, efficient and accurate systems are required for marine environmental monitoring and productive industries. A plasmonic sensor based on doubly deposited tapered optical fibers (DLUWTs-double-layer uniform-waist tapers) for the measurement of salinity is presented. The physical principle of the sensor, as well as its structure, is discussed, and its performance is experimentally demonstrated, obtaining very good sensitivities. The possibility of shifting towards higher wavelength measuring ranges associated with DLUWTs is also exploited. At the same time, we have considered the necessity of an extensive characterization of the behavior of the refractive index of salty water, both with variations in temperature and the composition of the salts dissolved. This is important due to the somehow changing reality of salinity measurements and the possibility of establishing new approaches for the determination of absolute salinity as opposed to practical salinity based on electrical conductivity measurements. The results obtained, which show high sensitivity and a good performance in general without the need for the use of semi-empirical algorithms, permit, in our opinion, an advance in the tendency towards refractometric determination of salinity with optical sensors apt for in situ, real-time, accurate measurements in realistic measuring conditions.

2.
Sci Rep ; 14(1): 18854, 2024 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-39143107

RESUMEN

The rapid and sensitive indicator of inflammation in the human body is C-Reactive Protein (CRP). Determination of CRP level is important in medical diagnostics because, depending on that factor, it may indicate, e.g., the occurrence of inflammation of various origins, oncological, cardiovascular, bacterial or viral events. In this study, we describe an interferometric sensor able to detect the CRP level for distinguishing between no-inflammation and inflammation states. The measurement head was made of a single mode optical fiber with a microsphere structure created at the tip. Its surface has been biofunctionalized for specific CRP bonding. Standardized CRP solutions were measured in the range of 1.9 µg/L to 333 mg/L and classified in the initial phase of the study. The real samples obtained from hospitalized patients with diagnosed Urinary Tract Infection or Urosepsis were then investigated. 27 machine learning classifiers were tested for labeling the phantom samples as normal or high CRP levels. With the use of the ExtraTreesClassifier we obtained an accuracy of 95% for the validation dataset. The results of real samples classification showed up to 100% accuracy for the validation dataset using XGB classifier.


Asunto(s)
Proteína C-Reactiva , Aprendizaje Automático , Humanos , Proteína C-Reactiva/análisis , Infecciones Urinarias/diagnóstico , Infecciones Urinarias/orina , Interferometría/métodos , Inflamación/diagnóstico , Inflamación/orina , Sepsis/diagnóstico , Sepsis/orina , Técnicas Biosensibles/métodos , Fibras Ópticas
3.
ACS Sens ; 9(6): 3027-3036, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38864606

RESUMEN

Surface plasmon (SP) excitation in metal-coated tilted fiber Bragg gratings (TFBGs) has been a focal point for highly sensitive surface biosensing. Previous efforts focused on uniform metal layer deposition around the TFBG cross section and temperature self-compensation with the Bragg mode, requiring both careful control of the core-guided light polarization and interrogation over most of the C + L bands. To circumvent these two important practical limitations, we studied and developed an original platform based on partially coated TFBGs. The partial metal layer enables the generation of dual-comb resonances, encompassing highly sensitive (TM/EH mode families) and highly insensitive (TE/HE mode families) components in unpolarized transmission spectra. The interleaved comb of insensitive modes acts as wavelength and power references within the same spectral region as the SP-active modes. Despite reduced fabrication and measurement complexity, refractometric accuracy is not compromised through statistical averaging over seven individual resonances within a narrowband window of 10 nm. Consequently, measuring spectra over 60 nm is no longer needed to compensate for small temperature or power fluctuations. This sensing platform brings the following important practical assets: (1) a simpler fabrication process, (2) no need for polarization control, (3) limited bandwidth interrogation, and (4) maintained refractometric accuracy, which makes it a true game changer in the ever-growing plasmonic sensing domain.


Asunto(s)
Fibras Ópticas , Resonancia por Plasmón de Superficie , Resonancia por Plasmón de Superficie/instrumentación , Resonancia por Plasmón de Superficie/métodos , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Tecnología de Fibra Óptica/instrumentación
4.
Sci Rep ; 14(1): 13377, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38862698

RESUMEN

In this work, optical fiber Bragg grating sensors were used to measure water velocity and examine how it was distributed in open channels. Several types of coatings were incorporated into the design of the sensors to examine their effects on the strain that the fibers experienced as a result of the water flow. Due to their low elastic coefficient, which reduced the hysteresis, the results indicated that the aluminum- and acrylate-coated fibers had the best performance. ANSYS-CFX V2020 R2 software was used to model the strain encountered by the fibers under various flow rates to assess the performance of the FBG sensors. The calculations and actual data exhibited good convergence, demonstrating the accuracy of the FBG sensors in determining water velocity. The study illustrated the usability of the proposal in both scenarios by contrasting its application in rivers and channels.

5.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38626737

RESUMEN

A novel fiber optic biosensor was purposed for a new approach to monitor amyloid beta protein fragment 1-42 (Aß42) for Alzheimer's Disease (AD) early detection. The sensor was fabricated by etching a part of fiber from single mode fiber loop in pure hydrofluoric acid solution and utilized as a Local Optical Refractometer (LOR) to monitor the change Aß42 concentration in Artificial Cerebrospinal Fluid (ACSF). The Fiber Loop Ringdown Spectroscopy (FLRDS) technique is an ultra-sensitive measurement technique with low-cost, high sensitivity, real-time measurement, continuous measurement and portability features that was utilized with a fiber optic sensor for the first time for the detection of a biological signature in an ACSF environment. Here, the measurement is based on the total optical loss detection when specially fabricated sensor heads were immersed into ACSF solutions with and without different concentrations of Aß42 biomarkers since the bulk refractive index change was performed. Baseline stability and the reference ring down times of the sensor head were measured in the air as 0.87% and 441.6µs ± 3.9µs, respectively. Afterward, the total optical loss of the system was measured when the sensor head was immersed in deionized water, ACSF solution, and ACSF solutions with Aß42 in different concentrations. The lowest Aß42 concentration of 2 ppm was detected by LOR. Results showed that LOR fabricated by single-mode fibers for FLRDS system design are promising candidates to be utilized as fiber optic biosensors after sensor head modification and have a high potential for early detection applications of not only AD but possibly also several fatal diseases such as diabetes and cancer.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Técnicas Biosensibles , Diagnóstico Precoz , Tecnología de Fibra Óptica , Fragmentos de Péptidos , Análisis Espectral , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides/análisis , Humanos , Tecnología de Fibra Óptica/métodos , Fragmentos de Péptidos/análisis , Técnicas Biosensibles/métodos , Análisis Espectral/métodos , Fibras Ópticas , Biomarcadores/análisis , Refractometría , Diseño de Equipo
6.
Micromachines (Basel) ; 15(2)2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38398904

RESUMEN

In the field of in situ measurement of high-temperature pressure, fiber-optic Fabry-Perot pressure sensors have been extensively studied and applied in recent years thanks to their compact size and excellent anti-interference and anti-shock capabilities. However, such sensors have high technological difficulty, limited pressure measurement range, and low sensitivity. This paper proposes a fiber-optic Fabry-Perot pressure sensor based on a membrane-hole-base structure. The sensitive core was fabricated by laser cutting technology and direct bonding technology of three-layer sapphire and develops a supporting large-cavity-length demodulation algorithm for the sensor's Fabry-Perot cavity. The sensor exhibits enhanced sensitivity, a simplified structure, convenient preparation procedures, as well as improved pressure resistance and anti-harsh environment capabilities, and has large-range pressure sensing capability of 0-10 MPa in the temperature range of 20-370 °C. The sensor sensitivity is 918.9 nm/MPa, the temperature coefficient is 0.0695 nm/(MPa∙°C), and the error over the full temperature range is better than 2.312%.

7.
Sensors (Basel) ; 24(2)2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38257630

RESUMEN

Bite force measurements are crucial in the realm of biomedical research, particularly in the areas of dentistry and orthodontic care. Various intraoral devices have been used to assess biting force, but each has limitations and drawbacks. Fiber optic sensors (FOSs) offer advantages such as electrical inertness, immunity to electromagnetic interference, and high sensitivity. Distributed fiber optic sensing allows an increase in the number of sensing points and can interrogate numerous reflections from scattering events within an optical fiber. We present four dental bites with heights of 6 mm, which enabled bilateral measurements. U-shaped sensors were prepared by embedding fibers into silicone by folding a single-mode fiber into four lines and multiplexing eight parallel nanoparticle-doped fibers. Dental bite models were created using two silicone materials (Sorta Clear 18 and Sorta Clear 40). The developed sensors were calibrated by applying weights up to 900 g, resulting in a linear response. Experiments were conducted to compare the efficacy of the dental bites. The collection of massive data was enabled by constructing a 2D map of the dental bites during multi-point sensing.

8.
Sensors (Basel) ; 23(23)2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-38067679

RESUMEN

We report on a study of the temperature dependence of the response of a BSO crystal based polarimetric current sensor with spectral interrogation. Two possible interrogation schemes are discussed. The spectral dependence of the optical rotation along the crystal caused by temperature and current changes is investigated, and approximate dependences for the sensitivities to current SI and temperature ST are derived. A mixed term in the response with spectral interrogation is revealed, the elimination of which is achieved by tracking wavelength shifts Δλ1 and Δλ2 of two distinct extrema in the polarimetric response. A temperature independent second degree equation for the current changes ΔI as a function of the measured spectral shifts is derived and tested.

9.
Sensors (Basel) ; 23(20)2023 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-37896707

RESUMEN

In the domain of optical fiber distributed acoustic sensing, the persistent challenge of extending sensing distances while concurrently improving spatial resolution and frequency response range has been a complex endeavor. The amalgamation of pulse compression and frequency division multiplexing methodologies has provided certain advantages. Nevertheless, this approach is accompanied by the drawback of significant bandwidth utilization and amplified hardware investments. This study introduces an innovative distributed optical fiber acoustic sensing system aimed at optimizing the efficient utilization of spectral resources by combining compressed pulses and frequency division multiplexing. The system continuously injects non-linear frequency modulation detection pulses spanning various frequency ranges. The incorporation of non-uniform frequency division multiplexing augments the vibration frequency response spectrum. Additionally, nonlinear frequency modulation adeptly reduces crosstalk and enhances sidelobe suppression, all while maintaining a favorable signal-to-noise ratio. Consequently, this methodology substantially advances the spatial resolution of the sensing system. Experimental validation encompassed the multiplexing of eight frequencies within a 120 MHz bandwidth. The results illustrate a spatial resolution of approximately 5 m and an expanded frequency response range extending from 1 to 20 kHz across a 16.3 km optical fiber. This achievement not only enhances spectral resource utilization but also reduces hardware costs, making the system even more suitable for practical engineering applications.

10.
BMC Musculoskelet Disord ; 24(1): 766, 2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37770871

RESUMEN

PURPOSE: Radiofrequency ablation is an increasingly used surgical option for ablation, resection and coagulation of soft tissues in joint arthroscopy. One of the major issues of thermal ablation is the temperature monitoring across the target areas, as cellular mortality is a direct consequence of thermal dosimetry. Temperatures from 45 °C to 50 °C are at risk of damage to chondrocytes. One of the most reliable tools for temperature monitoring is represented by fiber optic sensors, as they allow accurate and real-time temperature measurement via a minimally invasive approach. The aim of this study was to determine, by fiber Bragg grating sensors (FBGs), the safety of radiofrequency ablation in tissue heating applied to ex-vivo bovine hip joints. METHODS: Ex vivo bovine hips were subjected to radiofrequency ablation, specifically in the acetabular labrum, for a total of two experiments. The WEREWOLF System (Smith + Nephew, Watford, UK) was employed in high operating mode and in a controlled ablation way. One optical fiber embedding seven FBGs was used to record multipoint temperature variations. Each sensor was 1 mm in length with a distance from edge to edge with each other of 2 mm. RESULTS: The maximum variation was recorded in both the tests by the FBG1 (i.e., the closest one to the electrode tip) and was lower than to 2.8 °C. The other sensors (from FBG2 to FBG7) did not record a significant temperature change throughout the duration of the experiment (maximum up to 0.7 °C for FBG7). CONCLUSIONS: No significant increase in temperature was observed at any of the seven sites. The sensor nearest to the radiofrequency source exhibited the highest temperature rise, but the variation was only 3 °C. The minimal temperature increase registered at the measurement sites, according to existing literature, is not expected to be cytotoxic. FBGs demonstrate the potential to fulfil the strict requirements for temperature measurements during arthroscopic surgery.


Asunto(s)
Articulación de la Cadera , Ablación por Radiofrecuencia , Humanos , Bovinos , Animales , Temperatura , Artroscopía , Condrocitos
11.
Sensors (Basel) ; 23(16)2023 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-37631777

RESUMEN

A ratiometric fiber optic temperature sensor based on a highly coupled seven-core fiber (SCF) is proposed and experimentally demonstrated. A theoretical analysis of the SCF's sinusoidal spectral response in transmission configuration is presented. The proposed sensor comprises two SCF devices exhibiting anti-phase transmission spectra. Simple fabrication of the devices is shown by just splicing a segment of a 2 cm long SCF between two single-mode fibers (SMFs). The sensor proved to be robust against light source fluctuations, as a standard deviation of 0.2% was registered in the ratiometric measurements when the light source varied by 12%. Its low-cost detection system (two photodetectors) and the range of temperature detection (25 °C to 400 °C) make it a very attractive and promising device for real industrial applications.

12.
Sensors (Basel) ; 23(13)2023 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-37447798

RESUMEN

The present research exposes a novel methodology to manufacture fiber optic sensors following the etching process by Hydrofluoric Acid deposition through a real-time monitoring diameter measurement by computer vision. This is based on virtual instrumentation developed with the National Instruments® technology and a conventional digital microscope. Here, the system has been tested proving its feasibility by the SMS structure diameter reduction from its original diameter of 125 µ until approximately 42.5 µm. The results obtained have allowed us to demonstrate a stable state behavior of the developed system during the etching process through diameter measurement at three different structure sections. Therefore, this proposal will contribute to the etched fiber optic sensor development that requires reaching an enhanced sensitivity. Finally, to demonstrate the previously mentioned SMS without chemical corrosion, and the etched manufactured SMS, both have been applied as glucose concentration sensors.


Asunto(s)
Tecnología de Fibra Óptica , Fibras Ópticas , Tecnología de Fibra Óptica/métodos
13.
Sensors (Basel) ; 23(13)2023 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-37448034

RESUMEN

This paper presents reported machine learning approaches in the field of Brillouin distributed fiber optic sensors (DFOSs). The increasing popularity of Brillouin DFOSs stems from their capability to continuously monitor temperature and strain along kilometer-long optical fibers, rendering them attractive for industrial applications, such as the structural health monitoring of large civil infrastructures and pipelines. In recent years, machine learning has been integrated into the Brillouin DFOS signal processing, resulting in fast and enhanced temperature, strain, and humidity measurements without increasing the system's cost. Machine learning has also contributed to enhanced spatial resolution in Brillouin optical time domain analysis (BOTDA) systems and shorter measurement times in Brillouin optical frequency domain analysis (BOFDA) systems. This paper provides an overview of the applied machine learning methodologies in Brillouin DFOSs, as well as future perspectives in this area.


Asunto(s)
Tecnología de Fibra Óptica , Dispositivos Ópticos , Fibras Ópticas , Humedad , Aprendizaje Automático
14.
Sensors (Basel) ; 23(12)2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37420569

RESUMEN

In the paper, the effect of spontaneous Brillouin scattering (SpBS) is analyzed as a noise source in distributed acoustic sensors (DAS). The intensity of the SpBS wave fluctuates over time, and these fluctuations increase the noise power in DAS. Based on experimental data, the probability density function (PDF) of the spectrally selected SpBS Stokes wave intensity is negative exponential, which corresponds to the known theoretical conception. Based on this statement, an estimation of the average noise power induced by the SpBS wave is given. This noise power equals the square of the average power of the SpBS Stokes wave, which in turn is approximately 18 dB lower than the Rayleigh backscattering power. The noise composition in DAS is determined for two configurations, the first for the initial backscattering spectrum and the second for the spectrum in which the SpBS Stokes and anti-Stokes waves are rejected. It is established that in the analyzed particular case, the SpBS noise power is dominant and exceeds the powers of the thermal, shot, and phase noises in DAS. Accordingly, by rejecting the SpBS waves at the photodetector input, it is possible to reduce the noise power in DAS. In our case, this rejection is carried out by an asymmetric Mach-Zehnder interferometer (MZI). The rejection of the SpBS wave is most relevant for broadband photodetectors, which are associated with the use of short probing pulses to achieve short gauge lengths in DAS.


Asunto(s)
Fertilización , Frecuencia Cardíaca , Funciones de Verosimilitud
15.
Sensors (Basel) ; 23(12)2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37420766

RESUMEN

Submarine optical cables, utilized as fiber-optic sensors for seismic monitoring, are gaining increasing interest because of their advantages of extending the detection coverage, improving the detection quality, and enhancing long-term stability. The fiber-optic seismic monitoring sensors are mainly composed of the optical interferometer, fiber Bragg grating, optical polarimeter, and distributed acoustic sensing, respectively. This paper reviews the principles of the four optical seismic sensors, as well as their applications of submarine seismology over submarine optical cables. The advantages and disadvantages are discussed, and the current technical requirements are concluded, respectively. This review can provide a reference for studying submarine cable-based seismic monitoring.


Asunto(s)
Acústica , Tecnología de Fibra Óptica
16.
Adv Mater ; 35(39): e2301293, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37432766

RESUMEN

Sensing technologies based on plasmonic nanomaterials are of interest for various chemical, biological, environmental, and medical applications. In this work, an incorporation strategy of colloidal plasmonic nanoparticles (pNPs) in microporous polymer for realizing distinct sorption-induced plasmonic sensing is reported. This approach is demonstrated by introducing tin-doped indium oxide pNPs into a polymer of intrinsic microporosity (PIM-1). The composite film (pNPs-polymer) provides distinct and tunable optical features on the fiber optic (FO) platform that can be used as a signal transducer for gas sensing (e.g., CO2 ) under atmospheric conditions. The resulting pNPs-polymer composite demonstrates high sensitivity response on FO in the evanescent field configuration, provided by the dramatic response of modes above the total-internal-reflection angle. Furthermore, by varying the pNPs content in the polymer matrix, the optical behavior of the pNPs-polymer composite film can be tuned to affect the operational wavelength by over several hundred nanometers and the sensitivity of the sensor in the near-infrared range. It is also shown that the pNPs-polymer composite film exhibits remarkable stability over a period of more than 10 months by mitigating the physical aging issue of the polymer.

17.
Sensors (Basel) ; 23(8)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37112439

RESUMEN

Graphene-based materials have been increasingly incorporated to optical fiber plasmonic sensors due to the peculiar physical and chemical properties of these materials (hardness and flexibility, high electrical and thermal conductivity, and very good adsorption for many substances, etc.). In this paper, we theoretically and experimentally showed how the addition of graphene oxide (GO) to optical fiber refractometers permits the development of surface plasmon resonance (SPR) sensors with very good characteristics. We used doubly deposited uniform-waist tapered optical fibers (DLUWTs) as supporting structures because of their already proven good performance. The presence of GO as an effective third layer is useful to tune the wavelength of the resonances. In addition, the sensitivity was improved. We depict the procedures for the production of the devices and characterize the GO+DLUWTs produced in this way. We also showed how the experimental results are in agreement with the theoretical predictions and used these to estimate the thickness of deposited GO. Finally, we compared the performance of our sensors with other ones that have been recently reported, showing that our results are among the best reported. Using GO as the medium in contact with the analyte, in addition to the good overall performance of devices, permit consideration of this option as an interesting possibility for the future development of SPR-based fiber sensors.

18.
Sensors (Basel) ; 23(3)2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36772632

RESUMEN

Distributed fiber optic sensors (DFOS) have become a new method for continuously monitoring infrastructure status. However, the fiber's fragility and the installation's complexity are some of the main drawbacks of this monitoring approach. This paper aims to overcome this limitation by embedding a fiber optic sensor into a textile for a faster and easier installation process. To demonstrate its feasibility, the smart textile was installed on a pedestrian bridge at the University of Massachusetts Lowell. In addition, dynamic strain data were collected for two different years (2021 and 2022) using Optical Frequency Domain Reflectometry (OFDR) and compared, to determine the variability of the data after one year of installation. We determined that no significant change was observed in the response pattern, and the difference between the amplitude of both datasets was 14% (one person jumping on the bridge) and 43% (two people jumping) at the first frequency band. This result shows the proposed system's functionality after one year of installation, as well as its potential use for traffic monitoring.

19.
Sci Total Environ ; 857(Pt 2): 159563, 2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36265627

RESUMEN

Recently, human industrial practices and certain activities have caused the widespread spread of emerging contaminants throughout the environmental matrix, even in trace amounts, which constitute a serious threat to human health and environmental ecology, and have therefore attracted the attention of research scholars. Different traditional techniques are used to monitor water pollutants, However, they still have some disadvantages such as high costs, ecological problems and treatment times, and require technicians and researchers to operate them effectively. There is therefore an urgent need to develop simple, inexpensive and highly sensitive methods to sense and detect these toxic environmental contaminants. Optical fiber microfluidic coupled sensors offer different advantages over other detection technologies, allowing manipulation of light through controlled microfluidics, precise detection results and good stability, and have therefore become a logical device for screening and identifying environmental contaminants. This paper reviews the application of fiber optic microfluidic sensors in emerging environmental contaminant detection, focusing on the characteristics of different emerging contaminant types, different types of fiber optic microfluidic sensors, methodological principles of detection, and specific emerging contaminant detection applications. The optical detection methods in fiber optic microfluidic chips and their respective advantages and disadvantages are analyzed in the discussion. The applications of fiber optic biochemical sensors in microfluidic chips, especially for the detection of emerging contaminants in the aqueous environment, such as personal care products, endocrine disruptors, and perfluorinated compounds, are reviewed. Finally, the prospects of fiber optic microfluidic coupled sensors in environmental detection and related fields are foreseen.


Asunto(s)
Disruptores Endocrinos , Monitoreo del Ambiente , Humanos , Monitoreo del Ambiente/métodos , Microfluídica , Disruptores Endocrinos/análisis
20.
Sensors (Basel) ; 22(23)2022 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-36501796

RESUMEN

Here, we experimentally demonstrate a wedged fiber optic surface plasmon resonance (SPR) sensor enabling high-sensitivity temperature detection. The sensing probe has a geometry with two asymmetrical bevels, with one inclined surface coated with an optically thin film supporting propagating plasmons and the other coated with a reflecting metal film. The angle of incident light can be readily tuned through modifying the beveled angles of the fiber tip, which has a remarkable impact on the refractive index sensitivity of SPR sensors. As a result, we measure a high refractive index sensitivity as large as 8161 nm/RIU in a wide refractive index range of 1.333-1.404 for the optimized sensor. Furthermore, we carry out a temperature-sensitivity measurement by packaging the SPR probe into a capillary filled with n-butanol. This showed a temperature sensitivity reaching up to -3.35 nm/°C in a wide temperature range of 20 °C-100 °C. These experimental results are well in agreement with those obtained from simulations, thus suggesting that our work may be of significance in designing reflective fiber optic SPR sensing probes with modified geometries.


Asunto(s)
Refractometría , Resonancia por Plasmón de Superficie , Resonancia por Plasmón de Superficie/métodos , Refractometría/métodos , Diseño de Equipo , Tecnología de Fibra Óptica/métodos , Fibras Ópticas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA