Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Med Phys ; 48(7): 3654-3664, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33694162

RESUMEN

PURPOSE: Anthropometry is a method for quantifying body size and shape often used to derive body composition and health risk prediction models. Recent technology advancements led to development of three-dimensional (3D) optical scanners that can overcome most of the limitations associated with manual anthropometric data collection. However, each of the currently available devices offers proprietary measurements that do not match conventional anthropometric definitions. The aim of the current study was to develop and then evaluate the precision and accuracy of new "universal" 3D optical analysis software that calculates digital anthropometric volumes using identical standard landmarks across scanners. METHODS: Dual-energy x-ray absorptiometry (DXA) and air displacement plethysmography (ADP) total body and regional volume and fat mass reference measurements and 3D optical scans from two proprietary devices were collected from 356 participants to evaluate the robustness of total body and regional volume and fat mass measurements calculated by the developed software. Linear regression modeling with threefold cross validation was used to evaluate total body and regional fat masses from 3D scans. RESULTS: Total body and regional volumes measured by DXA and ADP had strong associations with corresponding estimates from the commercial 3D optical scanners coupled with the universal software (e.g., R2  = 0.98 for Styku and R2  = 1.00 for SS20, for both DXA and ADP comparisons). Regional body volumes also had strong correlation between DXA and the 3DO scanners (e.g., for arm, leg and trunk, respective R2 s of 0.75, 0.86, and 0.97 for Styku and 0.79, 0.89, and 0.98 for SS20). Similarly, there were strong associations between DXA- measured total body and regional fat mass and 3D optical estimates calculated by the universal software (e.g., for total body, arm, leg and trunk, respective R2 s of 0.86, 0.72, 0.77, and 0.88 for Styku and 0.84, 0.76, 0.78, and 0.85 for SS20). Absolute differences in volumes and fat mass between the reference methods and the universal software values revealed underlying proprietary scanner differences that can be improved when designing future devices. CONCLUSIONS: The current study suggests that, when compared against values calculated using DXA and ADP, the universal software was able to measure total and regional body volumes reliably from scans obtained by two different scanners. The universal software, with future refinements, combined with potential optical scanner design improvements, creates new opportunities for developing large multicenter anthropometric databases with uniformly defined body dimensions that can be used for modeling health risks. CLINICAL TRIAL REGISTRATION ID: Shape Up! Adults Study, NCT0363785.


Asunto(s)
Composición Corporal , Pletismografía , Absorciometría de Fotón , Tejido Adiposo , Adulto , Antropometría , Humanos , Programas Informáticos
2.
Archaeol Anthropol Sci ; 11(5): 2167-2179, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31565085

RESUMEN

Body mass prediction from the skeleton most commonly employs femoral head diameter (FHD). However, theoretical predictions and empirical data suggest the relationship between mass and FHD is strongest in young adults, that bone dimensions reflect lean mass better than body or fat mass and that other femoral measurements may be superior. Here, we generate prediction equations for body mass and its components using femoral head, neck and proximal shaft diameters and body composition data derived from dual-energy x-ray absorptiometry (DXA) scans of young adults (n = 155, 77 females and 78 males, mean age 22.7 ± 1.3 years) from the Andhra Pradesh Children and Parents Study, Hyderabad, India. Sex-specific regression of log-transformed data on femoral measurements predicted lean mass with smaller standard errors of estimate (SEEs) than body mass (12-14% and 16-17% respectively), while none of the femoral measurements were significant predictors of fat mass. Subtrochanteric mediolateral shaft diameter gave lower SEEs for lean mass in both sexes and for body mass in males than FHD, while FHD was a better predictor of body mass in women. Our results provide further evidence that lean mass is more closely related to proximal femur dimensions than body or fat mass and that proximal shaft diameter is a better predictor than FHD of lean but not always body mass. The mechanisms underlying these relationships have implications for selecting the most appropriate measurement and reference sample for estimating body or lean mass, which also depend on the question under investigation.

3.
Br J Nutr ; 121(3): 285-290, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30444206

RESUMEN

Newborn adiposity, a nutritional measure of the maternal-fetal intra-uterine environment, is representative of future metabolic health. An anthropometric model using weight, length and flank skinfold to estimate neonatal fat mass has been used in numerous epidemiological studies. Air displacement plethysmography (ADP), a non-invasive technology to measure body composition, is impractical for large epidemiological studies. The study objective was to determine the consistency of the original anthropometric fat mass estimation equation with ADP. Full-term neonates were studied at 12-72 h of life with weight, length, head circumference, flank skinfold thickness and ADP measurements. Statistical analyses evaluated three models to predict neonatal fat mass. Lin's concordance correlation coefficient, mean prediction error and root mean squared error between the predicted and observed ADP fat mass values were used to evaluate the models, where ADP was considered the gold standard. A multi-ethnic cohort of 468 neonates were studied. Models (M) for predicting fat mass were developed using 349 neonates from site 1, then independently evaluated in 119 neonates from site 2. M0 was the original anthropometric model, M1 used the same variables as M0 but with updated parameters and M2 additionally included head circumference. In the independent validation cohort, Lin's concordance correlation estimates demonstrated reasonable accuracy (model 0: 0·843, 1: 0·732, 2: 0·747). Mean prediction error and root mean squared error in the independent validation was much smaller for M0 compared with M1 and M2. The original anthropometric model to estimate neonatal fat mass is reasonable for predicting ADP, thus we advocate its continued use in epidemiological studies.


Asunto(s)
Tejido Adiposo , Antropometría/métodos , Composición Corporal , Pletismografía/estadística & datos numéricos , Adiposidad , Peso Corporal , Estudios de Cohortes , Femenino , Cabeza , Humanos , Recién Nacido , Masculino , Pletismografía/métodos , Reproducibilidad de los Resultados , Grosor de los Pliegues Cutáneos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA